Page 1 of 6 Celebration Before beginning installation of the CELEBRATION, check the enclosed bill of materials to ensure that all parts are present and undamaged. Read all installation instructions and familiarize yourself with the system s components. This is extremely important because parts will become permanently damaged if they are installed incorrectly! To help with identification, all parts are poly-bagged and labeled. Parts and May include some or videotape Bill of Materials (BOM) Components all of the following: PART LIST A F A E B D C D E F C B CELEBRATION Panel 2 x 2, 4 x 4 or 30 x 30 DONN Brand Air Diffuser FINELINE Main Tee (12 lengths) FINELINE Cross Tee (4 lengths) UA-25 U-Molding (10 lengths) CA-5 Retrofit U-Molding (10 lengths) CA-5 Retrofit Slip-On Molding (10 lengths) T-15 Panel Hold-Down Clip (10 lengths) CA-1 Arrowhead Reveal Spacer CA-4 Round Reveal Spacer
Page 2 of 6 Step 1: Perimeter Panel 1. A. B. C. Install the appropriate grid module using DXF 1/4-inch FINELINE grid with UA 25 wall molding. When installing, be sure that the module is square. Create perimeter panels by cutting full panels to fit the perimeter spaces in the grid installation. Measure the opening and mark the appropriate cut points on a full panel. 1. D. E. F. Measured Dimension Note the measurement points in this graphic. Score between the cut marks with a straight edge and sharp SHEETROCK knife. Cut the edge of the panel at each cut point with snips. G. H. Note: Most CELEBRATION panels are aluminum. Steel CELEBRATION panels are also available and must be cut using a band saw or hand-held metal cutting saw. Bend the panel at the score until it breaks free. To ensure that the panels lay flat at the perimeter, lock each in place by using two T-15 Hold-Down Clips. These clips are used in conjunction with UA25 U-molding.
Page 3 of 6 Step 2: Accessory Panel A. B. C. Find the locations of all light fixtures, sprinkler heads and speakers and install the appropriate accessory panel for each. These panels can be ordered pre-punched with a hole or they can be field-cut as needed. Optional light fixture trim can also be ordered. D. E. F. Light fixture installed with the optional trim. Before installing an air diffuser, the exposed grid flange can be spray-painted to match the panel color. First, install the air diffuser frame into the grid. G. H. H. Then, install the air diffuser panel into the air diffuser frame. Finally, install the air diffuser boot.
Page 4 of 6 Step 3: Field Panel A. B. C. hinge side of panel CELEBRATION panels have a unique hinge design that works with regular 1/4-inch DXF FINELINE ceiling grid for easy installation and removal. push up into reveal area shift panel to rest flange on grid D. E. F. push up to lock panel Here s how the panel hinge and the grid flange fit together. To install the field panels, hook the hinged side of each panel onto the flange of the grid and press along the panel edge to lock it into place. Do not press on the panel face. For a field panel installed adjacent to a cut perimeter panel, insert a 4-inch length of Arrowhead Reveal Spacer into the channel at each corner. G. For a field panel installed adjacent to an air diffuser or light fixture, insert a 4-inch length of Round Reveal Spacer into the channel at each corner.
Step 4: Releasing Panels Page 5 of 6 A. B. C. tapered edge for screwdriver release hinge side of panel To disengage a panel, locate the side opposite the hinge. Insert a flat screwdriver blade into each corner to release the panel from the grid. Allow the panel to swing down on its hinge. D. L. To remove the panel, lift the panel off the grid flange to disengage the hinge mechanism. M. 1.
Technical Service 800 USG.4YOU Web Site www.usg.com Samples/Literature 888 874.2450 Samples/Literature E-mail samplit@usg.com Samples/Literature/Fax 888 874.2348 Customer Service 800 950.3839 Note All products described here may not be available in all geographic markets and are subject to change without notice. Consult your local sales office or representative for information. Trademarks The following are trademarks of USG Interiors, Inc. or a related company: CELEBRATION,DONN, FINELINE,USG. Notice We shall not be liable for incidental or consequential damages, directly or indirectly sustained, nor for any loss caused by application of these goods not in accordance with current printed instruction or for other than intended use. Our liability is expressly limited to replacement of defective goods. Any claim shall be deemed waived unless made in writing to us within thirty (30) days from the date it was or reasonably should have been discovered. Safety First! Follow good safety and industrial hygiene practices during handling and installation of all products and systems. Take necessary precautions and wear appropriate personal protective equipment as needed. Read material safety data sheets and related literature on products before specification and/or installation. Manufactured by USG Interiors, Inc. 125 South Franklin Street Chicago, IL 60606 IC462/rev. 7-03 2003, USG Interiors, Inc. Printed in U.S.A.