produces and delivers products worldwide can provide the optimal are dedicated to supplying you with superior advice and global support.



Similar documents
HV glass suspension insulator U70BS and U70BL type Ball and socket type Standard profile

Medium voltage insulator

TECHNICAL SPECIFICATION FOR HIGH TENSION LINE HARDWARE AND ACCESSORIES FOR ACSR PANTHER & WOLF CONDUCTOR

The very Best. ANSI Post Insulators 2016

Transmission Silicone Insulators Line Post 69 kv to 161 kv

1ZSE en, Rev. 8. Transformer bushings, type GOE and GOE(2) Technical guide

Composite Insulators Suspensions Line Posts Brace Posts Station Posts

3.1.1 Full Type Tests & Routine Tests according to Clause 8 2 & Instructions For Installation, Operation & Maintenance

Transformer Bushings for GIS

PPS-PPQ-BT-PIAS RESIN INSULATORS FOR OIL INSULATED ELECTRICAL MACHINES

American National Standard. For Insulators. Wet Process Porcelain and Toughened Glass Suspension Type ANSI/NEMA C

Directory chapter 02 - DIN Power (to 6 A) Types D, E, F, FM, 2F, F9, interface connectors I/U Technical characteristics types D and E

MiCAFIL. 1 RIP Technology. Bushings. Z. Zic 09/2003

Machine Screws, Dowel Pins and Hardware

Veri*Lite Deadend & Suspension Insulators for 15-69kV Applications

HTV SILICONE COMPOSITE INSULATORS FOR HVDC APPLICATIONS - LONG- TERM EXPERIENCES WITH MATERIAL AND DESIGN FOR 500KV AND ABOVE

AutoLink Three-Phase Sectionalizer Specifications. Scope. General. Applicable Standards. Operating principle

Metal Pressfitting Pipe Systems

DS 600. A contact free flux gate based current measurement sensor 600A rms

Design Test Report Veri*Lite Suspension Insulators Catalog Numbers: , , ,

Explosion proof enclosures

FAQs-Main switchboard design criteria

25-kV Apparatus Bushings B Series (bolt-in) for Elbow to Air-Insulated Service 200 Amp, 600 Amp and 1250 Amp

VdS en. VdS Guidelines for water extinguishing systems. Non-return valves. Requirements and test methods. VdS en : (01)

08. SEK IDC CONNECTORS

High-ohmic/high-voltage resistors

Vertical Break Parallel (VBP) / Vertical Break Slant (VBS)

Calculating Creepage and Clearance Early Avoids Design Problems Later Homi Ahmadi

Optocoupler, Phototransistor Output, AC Input

Amphenol C 091 A/B/D. Circular Connectors. Amphenol-Tuchel Electronics GmbH

Technical Data. 7. Bearing Fits. 7.1 Interference. 7.2 Calculation of interference F B LLLLLLLLL( A-54

PV module safety qualification according to IEC 61730:2004 EN 61730:2007

High-ohmic/high-voltage resistors

How to order: Please prefix the mbo part number or description with R239- example: R /014

Unified requirements for systems with voltages above 1 kv up to 15 kv

7000 Series Buccaneer

SURGE PROTECTIVE DEVICES

CLAMPS CONNECTORS & EQUIPOTENTIAL RING

KIRÁLY TRADING KFT H-1151 Budapest Mogyoród útja tel: Clamps Clamping devices

1ZSC AAC en, Rev. 7. Resin impregnated paper bushing, oil to air, type GSB Technical guide

Type: EASY719 DC RC Article No.: Ordering information Relay outputs Quantity 6 Power supply V DC 24 V DC. Description

TIGER Drylac U.S.A., Inc Swenson Avenue St Charles, IL T F office.us@tiger-coatings.us

LOW VOLTAGE RING TYPE MEASURING CURRENT TRANSFORMERS

High-Voltage Circuit-Breakers 3AP1/ kv up to 550 kv. Power Transmission and Distribution

Magnetic and Hydraulic-Magnetic Circuit Breaker 8340-G2...

Mounting Instructions for SP4 Power Modules

BUMAX. REYHER your partner for the BUMAX range

RAILWAY CATENARY SYSTEMS. Components and Systems for the Electrification of Railway Lines. ibemo

PC/104, PC/104 -Plus, VarPol connectors

Application Switchgear for industrial and commercial applications. U e V AC 230/ (per pole)

GLASS SUSPENSION INSULATOR

Sediver toughened glass suspension insulators catalog

OLI. Oil level indicator

ALTERNATIVE METHODS FOR INTERNAL ARC TESTS ON 12 KV AND 24 KV METAL-ENCLOSED SWITCHGEARS WITH COMPACT RMU

Trapezoidal-Connectors Series TMC

EFFECTS OF CORONA RING DESIGN ON ELECTRIC FIELD INTENSITY AND POTENTIAL DISTRIBUTION ALONG AN INSULATOR STRING

Machine devices, jig devices

SF 6 Gas Insulated Switchgear Type SDF for 170 kv

a Nexans company Catalogue 2014

Two most common lock nut groups: 1-Prevailing Torque Type Lock Nuts:

Power transformers. Special transformers Railway

Product Safety Considerations for Insulation Coordination of Low- Voltage Equipment. Scott Aldous, Compliance Engineer

Surface Mount Multilayer Ceramic Chip Capacitor Solutions for High Voltage Applications

Mounting Instructions. Torque Transducer. A en

Depend-O-Lok FxE Expansion Coupling. System No. Submitted By Spec Sect Para Location Date Approved Date. DEPEND-O-LOK FxE EXPANSION COUPLING

Application Bulletin AB-2 Isolator High Voltage Safety Standards

Power Capacitor Units for improved power quality

EJOT Spiralform. The thread formers for metal. EJOT The Quality Connection

33.6W Power over Ethernet Waterproof Adapter PoE Plus Single Port Injector for Outdoor Application

Pressure monitoring equipment for oil-sf 6. bushings, type GOEK

VDE Information. Degree of Pollution, Clearances and Creepage Distances and Insulating Materials

5SV Residual Current Protective Devices

PVC Pipe PVC SCHEDULE 40. Nominal Pipe Size (in.) 1/8. Average I.D. O.D.

MEDIUM VOLTAGE CE-BF SWITCHBOARDS. UP TO 40.5 kv. CE - BF - C - en - REV

Keystone Network Isolator with ESD- and Lightning Protection

Cable Trays Technical Instructions & Specifications

UGVCL/SP/591/11KV HT AB CABLE

HLC A1... HLC B1... HLC F1... Data Sheet. Load cells. Special features. B en

High Voltage Circuit Breakers 3AP Type 72.5 kv to 800 kv Answers for energy.

1 Form A Solid State Relay

Manufacturing, Supply & Quality Plan for Tower Bolts. SL Tower Bolt Market Penetration

PUSH-PULL CABLES CONTROL SYSTEMS

AC Line Rated Ceramic Disc Capacitors Class X1, 760 V AC / Class Y1, 500 V AC

Technical Data. Dimensions

pvc well casing & drop pipe

SITEMA PowerStroke. Technical Information TI-P11. 1 Function. 2 Applications. Mould Closing Devices series FSK. Contents

1 Form A Solid State Relay

HSD High Speed Data interconnection

Outdoor Use Waterproof I/O Connectors (Optical / Modular / Electrical) FO-BH, FO-BC, NT5, JN2 / W Series

THREAD-FORMING SCREWS CUT COSTS WITH DIRECT FASTENING

Installation guide for the SafeLine type anchorage device. Tested in compliance with EN 795: No.: SE-...

METAL-CLAD AND METAL-ENCLOSED SWITCHGEAR 3.6KV~40.5KV. tgood.com. Energy. Fast.

Spiroflex spiral-wound gaskets

ODU MEDI-SNAP. Miniature Circular Connectors with Push-Pull Locking Made of Plastic or Metal.

PD30ETB20xxIS. Photoelectrics, Background Suppression reflective with IR light. Main features. Description

Pressure regulating valve with modulating kit, type DRV

Optocoupler, Phototransistor Output, with Base Connection, 300 V BV CEO

(English language translation, the original version is in French language) Hilti HSL-3

For the electronic measurement of current: DC, AC, pulsed..., with galvanic separation between the primary and the secondary circuit.

NATUS NES / NES-H Draw-out Type Medium Voltage Switchgear Systems. Safe energy distribution that meets the highest industrial requirements

Transcription:

www.ppcinsulators.com The very Best. The very Best. That s what we deliver. ong od Insulators Only a company that develops, produces and delivers products worldwide can provide the optimal solution for your requirements. The specialists of PPC Insulators are dedicated to supplying you with superior advice and global support. PPC Insulators quality products and service provide time-tested value to fulfill your needs! Please visit us on the web at www.ppcinsuators.com evision /003

Introduction ong od Insulators Best Performance in Engineering Your equest is our Challenge Excellent design with extra high strength > ISO 900 > IEC > DIN > ÖNOM PPC Insulators is a specialist in long rod insulators with a 60 year history of experience and development of these porcelain insulators. We produce a comprehensive range of products for overhead transmission lines up to highest system voltages of 55 kv with the most progressive technology, engineering and in-service life. Index > Standards High Voltage Overhead Transmission ines PAGE 4 IEC Publications PAGE 4 DIN PAGE 4 ÖNOM PAGE 4 Couplings PAGE 5 ocking Device PAGE 5 > Design Electrical Values PAGE 6 Shed Profiles PAGE 6 Creepage Distances PAGE 7 > Production Insulating Material PAGE 8 Insulator Cap Material (ittings) PAGE 8 Cementing PAGE 8 Marking PAGE 8 Inspection and Testing PAGE 9 > Application and Advantages PAGE 0 > Ball and Socket Couplings PAGE > ocking Devices PAGE 4 > Clevis and Tongue Couplings PAGE 6 > ong od Insulators with Ball and Socket Couplings PAGE 8 > ong od Insulators with Clevis and Tongue Couplings PAGE 9 Introduction ong od Insulators

Standards ong od Insulators High Voltage Overhead Transmission ines To specify the correct porcelain long rod insulator, the following characteristics have to be defined: > specified mechanical failing load > minimum nominal creepage distance > environmental conditions and grade of pollution > type of coupling > standard lightning impulse withstand voltage > wet power frequency withstand voltage Designation PPC Insulators manufactures long rod insulators according to IEC 60433 (998) (including the former German standard DIN 48006 (986)). According to IEC 60433 a porcelain long rod insulator is, for example, defined as follows: 60 B 550 long rod insulator 60 specified mechanical failing load (kn) B ball and socket coupling C clevis coupling (when B is replaced by C) 550 standard lightning impulse withstand voltage [kv) ong od Insulators Standards ocking Devices or ball and socket couplings, split pins conforming to IEC 6037 (984) are normally used. Most of these pins also comply with DIN 48063 (978) = ÖNOM E430 (988) ÖNOM E43 (988) or ball and socket couplings complying to ÖNOM E404 (988) the locking is performed by a corresponding split pin. The clevis coupling is locked by a corresponding connecting bolt with grooved nut and cotter pin according to DIN 48073 These connecting bolts are not part of regular supplies, but upon customer request, PPC can procure these connecting bolts. Standards ong od Insulators According to the former German standard DIN 48006 the same insulator was defined as: P 75//50 P porcelain long rod insulator with ball According to the former Austrian standards ÖNOM a long rod insulator was defined as shown in the following example: 60/5-5 G and socket coupling porcelain long rod insulator with clevis coupling (when P is replaced by G) 75 core diameter (mm) number of sheds 50 total length of the long rod insulator (mm) porcelain long rod insulator with normal shed spacing 60 core diameter (mm) 5 number of sheds 5 mechanical failing load, average value (kn) Couplings Three types of couplings for porcelain long rod insulators are available: Ball and socket couplings conforming to. IEC 600 (987) = DIN 48064 (98) = ÖNOM E45 (988). ÖNOM E404 (988) Clevis couplings conforming to IEC 6047 (977) = DIN 48073 (975) = DIN 48074 (990) = ÖNOM E46 (984) Variations are made by changes in the initial letter as shown: H V N W standard design with normal creepage distance normal creepage distance with higher strength anti-pollution type fog type with alternating sheds PAGE 4 PAGE 5

Design ong od Insulators Shed Profiles according to Standard IEC 6085 Plain shed ong od Insulators Design Creepage Distances Porcelain long rod insulators are produced with different shed profiles to optimize performance according to environmental conditions and the grade of pollution. or example, this includes Design ong od Insulators Desert shed > og and Salt Pollution > Dust Pollution > Industrial Pollution Standard shed acc. to DIN shed profiles for coastal areas (fog and salt pollution) which require a high protected creepage distance aerodynamic shed profiles for areas with desert conditions (dust pollution) shed profiles for areas with heavy industrial pollution Alternating shed Electrical Values The insulation performance of a long rod insulator is a function of the length, creepage and arcing distance of the insulating part and follows the standard IEC 6007 (98-996). It should be noted that to provide an accurate picture of all electrical relationships, a real tower should be constructed with all relevant distances to earth in conjunction with insulators, arcing horns and protective devices. The recommendations of standard IEC 6085 (986) are valid for the design of the shed profiles of porcelain insulators and for the determination of the adequate tolerances. Electric Arc Discharge along a ong od Insulator with Protective ittings PAGE 6 PAGE 7

Production ong od Insulators ong od Insula tors Insulating Material The insulator body of the unit is made from high quality aluminum oxide porcelain, C-30, which conforms to IEC 6067 (995-999). By customer request, we can also manufacture from aluminum oxide porcelain, C-0. Glazing provides a dirt repellent surface. Glazing is normally brown in color; however grey can also be provided upon request. Production Production ong od Insulators Marking Each porcelain long rod insulator carries the trademark of the PPC Insulators and of the manufacturing factory and the date of manufacture as well as the type designation and the specific mechanical failing load in accordance with standard IEC 60433. Inspection and Testing Porcelain long rod insulators are tested according to standard IEC 60383 (993). Cementing Cementing is provided with a lead-antimony alloy as standard although it is also possible to provide Portland cement or sulfur cement. Insulator Cap Material (ittings) Insulator caps are manufactured in malleable cast iron, in minimum EN-GJMB-550-4 or EN-GJMW-450-7, according to standard DIN EN 56 (997). The caps are hot dip galvanized according to standard DIN EN ISO 46 (999) with a zinc weight of min. 600 g/m (min. 85 µm) average value. Inspection and Testing of Porcelain ong od Insulators according to Standard IEC 60383 Test programme Type Sample outine tests tests tests Dry lightning impulse withstand voltage test Wet power-frequency withstand voltage test Mechanical failing load test Thermal-mechanical performance test Verification of the dimensions Verification of the displacements Verification of the locking system Temperature cycle test Porosity test Galvanizing test outine visual inspection outine mechanical test PAGE 8 PAGE 9

Application and Advantages ong od Insulators underribs on sheds not required as the core parts between the sheds contribute to insulation protection against power arcs is achieved by the addition of protective fittings > cascade flashovers are not possible > immune to thermal puncture minimum use of metal parts, which minimizes corrosion problems and also provides > lower weight for a complete insulator set > simpler mounting of strings > low level of H interference to radio and television transmissions long rod insulators can be used for tension and compression loads ong od Insulators Application and Advantages long rod insulators can be checked ultrasonically for mechanical soundness electrically and mechanically stressed zones are separated routine test load = 80% of the specified mechanical failing load long rod insulators are recommended for use in direct current applications because there is > no pin corrosion > no ion migration > no problems with thermal runaway effects minimum total life cycle costs through high reliability Application and Advantages ong od Insulators puncture proof ong rod insulators are solid core and the theoretical puncture path through the porcelain body is almost equal to the dry arcing distance. Since porcelain has several times the dielectric breakdown strength of air, flashover, if any, always occurs in the air outside the porcelain body. low surface leakage current resulting in reduced transmission losses self-fractures of long rod insulators made of aluminum oxide porcelain are not known the creepage distance is comprised of sheds and core parts which have > good self-cleaning properties with respect to climatic conditions > better insulation performance under pollution conditions packaging in crates offers the maximum protection during shipping and storage lowest maintenance costs insulator body made of aluminum oxide porcelain > high mechanical strength > free of internal stresses > no measurable aging > resistant to salt pollution > high resistance to temperature variations > high resistance to vandalism PAGE 0 PAGE

Ball and Socket Couplings ong od Insulators ong od Insulators Ball and Socket Couplings Standard IEC 600 Dimensions of the Pin Ball Designated size d d h r r r * 3 r 4 of coupling (mm) (mm) (mm) (mm) (mm) (mm) (mm).9.8 9. 35 35 3.5.5 + -. -.3 -. 6 7 0 4 5 8 9 33.3 3.4 3 50 3 3 + -. -.5 -.3.5 4 9.5 7 60 5.7 3.5 + -.3 -.6 -.4-49 -.4 -.8 -.7-40 70 6.6 4 +.5 57 -.5 -.9 -.8-3.5 55 80 8 4.5 +.5 Clearance between the Pin Ball and the Socket End D d d D P D d d D 3 Q Ball and Socket Couplings ong od Insulators * given for guidance 3 33 Dimensions of the Socket End 65 7 -.6 -. -.9-70 90 0 5 +.5 Designated size D D * D * 3 H H * 3 4 5 T ** of coupling (mm) (mm) (mm) (mm) (mm) (mm) (mm) (mm) (mm) (mm).5 +.3 4.5 4.5 0.5 +.3 5.5 35 4.5 4 4.8 6A 9. +.6 34.5 34.5 4.5 +.6 0.5 3 3 3 5 5.5 The pin ball in the socket entry. * clearance between the pin ball and the locking device Dimensions of the Twin-Balled Pins Designated size h 4 of coupling (mm) 47 -.5 The pin ball in the socket interior. Designated size D - d D - d D 3 - d P Q * of coupling Min. Max. Min. Min. Max. Min. 0.6 3.0.7.7.4 3.9.6 6A. 5.0... 4.0.6 6B. 5.0.. 3.6 6.5 3.7 0.0 5.4.5.5.0 4.5.0 4.5 6.4.0.0.5 6.7.8 8 3.0 7.4.0.0.5 7. 3.0 3 3.0 7.9.5.5 3.0 8. 3.5 +.6 6B 9. +.6 34.5 34.5 7 5 3 3 3 5 7.9 6 63-3.0 0 3 +. 4.5 4.5 0.5 +. 8.5 7 6 3.5 7 7.0 + 0 0 83-3. h 4 4 7 +.5 5 5 3.5 +.5 33.5 40 5 4 0 8.7 4 90-3.5 8 3 +.9 59 59 6 +.9 36.5 55 8 4.5 0.5 8 97-3.5 3 36 * minimal value ** minimal value of the thickness of the locking device +3.3 +3.3 67.5 67.5 30 4 70 0 5 4.5 3 0-4.0 PAGE PAGE 3

S ocking Devices ong od Insulators ong od Insulators ocking Devices Standard IEC 6037 Dimensions of the Split - Pin (V-Type) for Ball and Socket Couplings X Section X - X Dimensions of the W-Clip for Ball and Socket Couplings S 5 4 6 3 4 3 3 ocking Devices ong od Insulators X T 5 T Designated size of Standard V-type split-pin Alternative standard coupling V-type split-pin * S T min min min ' max (mm) (mm) (mm) (mm) (mm) (mm) (mm). ± 0, 4.8. 3.3 8..5 9 7.3 6A 3. ± 0. 5.5. 3.8 0.3 3.0 38 9. 6B 3. ± 0. 7.9 + 0. 4.8 0.7 3.0 38 9.7 0 3. ± 0. 7.0. 4.8 0.7 3.0 49 9.7 4 4.0 ± 0. 8.7. 5.7.8 3.5 60.7 8 4.5 ± 0. 0.0.3 6. 3.8 3.5 7.7 3 5. ± 0..5.3 7. 5.8 3.5 8 4.7 * all the dimensions are the same as for standard split-pins, except the value replaced by ' The dimension max shall be specified by the purchaser of the split-pin. V-Type Split-Pin in ocking and in Coupling Positions Designated size 3 4 5 6 3 4 5 3 max S T of standard coupling (mm) (mm) (mm) (mm) (mm) (mm) (mm) (mm) (mm) (mm) (mm) (mm) (mm) (mm) (mm) (mm) 5 0 4 3 9 4.6-0 37 ±.5.0 4 ±.5 8.0 3.5 3.0.5. + 0. 4.8 + 0. 6A 8 5 9 4 5 + -0 50 ±.5 5.5 36 ±.5 0.5 3.5 3.0.5.5 + 0. 5.5 + 0. 6B 8 5 9 4 5 + -0 50 ±.5 5.5 36 ±.5 0.5 3.5 4.5.5.5 + 0. 7.9 + 0. 0 30 5 9 4 5 + -0 6 ±.5 5.5 4 ±.5 0.5 3.5 4.5.5.0 + 0. 7.0 + 0. 4 30 5 9 5 5 + -0 7 ±.5 5.5 50 ±.5 0.5 3.5 5.0.5.0 + 0. 8.7 + 0. 8 4 3 6 8 6 + -0 83 ±.5 6.0 6 ±.5.5 4 3.0 6.0 3.0. + 0. 0.0 + 0. 3 6 36 6 4 33 7 + -0 96 ±.5 8.0 7 ±.5 6.0 4 3.0 7.0 3.0.6 + 0..5 + 0. W-Clip in ocking and in Coupling Positions A Socket entry Socket entry Socket entry Socket entry A Split-pin in locking position Split-pin in coupling position W-clip in locking position W-clip in coupling position PAGE 4 PAGE 5

Clevis and Tongue Couplings ong od Insulators l l Standard IEC 6047 Dimensions of Clevis and Tongue Coupling A B n d Tongue H ong od Insulators Clevis and Tongue Couplings Bolt Standard DIN 48 073 Dimensions of Connecting Bolts Shape N with cotter pin and disk d d d e marking h l Shape S with grooved nut and cotter pin d d 3 d width of flats thread Clevis and Tongue Couplings ong od Insulators A m Clevis Section A - A Designation d d n B m H l (mm) (mm) (mm) (mm) (mm) (mm) (mm) (mm) Min..8 4 4 0 3-45 3 Nom. 3 4 3 4 3 - - - Max. 3.5 5 3.5 5.5 5 34.5 5 - Min. 8.6 9.8 7.5 0 4.5 46-65 9 Nom. 9 0 9 0 8 - - - Max. 9.4.4 9.5 48.5 - Min..8 3 7.5 0 7.5 53-75 Nom. 4 9 0 - - - Max..6 4.6 9.5 5 55.5 5 - Min. 4. 6 3 6 8 57.5-80 5 Nom. 5 7 4 6 3 - - - Max. 5.6 8 5.5 8 6.5 60 6.5 - Min. 7. 9 3 6.5 67-90 8 Nom. 8 30 4 6 6 - - - Max. 8.6 3 5.5 8 30 69.5 30 - Min. 3. 33 3 6 4.5 77-00 3 Nom. 3 34 4 6 9 - - - Max. 3.6 35 5.5 8 33 79.5 33 - d blind holes cotter pin h s d cotter pin Designation d l + * d d 3 e + h ± Width of Disk Cotter pin flats s acc. to acc. to (mm) (mm) (mm) (mm) (mm) (mm) (mm) DIN 44 DIN 94 N 3 3 + 0.3 5 8, 3, 40, 45-5 - - 5 S 3.6 5 M - 4 9-4 x 5 N 9 + 0.3 34, 38, 43, 48, 5, 60, 05, 6-6 - - 5 x 45 9 S 9.6 5, 45, 65, 85, 05, 5 5 M6 x.5-6 4-4 x 40 N + 0.5 6-6 - - 3 5 x 45 34, 38, 43, 48, 5, 57, 60, 66 S.3 5 M8 x.5-6 7-4 x 40 N 5 5 + 0.3 48, 65, 0, 30, 50, 70, 90, - 6 - - 6 6 S 5.8 0, 30, 50, 70, 90, 30, 330 M x.5-6 3-5 x 50 N 8 8 + 0.4 43, 48, 5, 57, 75, 83, 5, - 8 - - 9 6 S 8.8 35, 55, 75, 95, 35, 335 M4 x - 0 36-5 x 50 N 3 3 + 0.5 43, 48, 5, 57, 83, 5, 35, - 8 - - 33 6 S 3-0.8 55, 75, 95, 35, 335 M7 x - 0 4-5 x 7 * Section of the length depending on outside distance of clevis PAGE 6 PAGE 7

Ball and Socket Couplings ong od Insulators ong od Insulators with Ball and Socket Couplings d d ong od Insulators with Clevis and Tongue Couplings d Clevis and Tongue Couplings ong od Insulators d Characteristics of ong od Insulators with Ball and Socket Couplings "B" according to the Standard IEC 60433 (998) and according to the former German Standard DIN 48006 / Part Designation Core Highest Standard Wet Specified outine Minimum Maximum Standard according according diameter system lightning power mechanical mechanical nominal nominal coupling to to former d voltage impulse frequency failing test creepage length size Um withstand withstand load load distance (pin voltage voltage (6 mm/kv) diameter) d IEC 60433 DIN 48006/ (mm) (kv) (kv) (kv) (kn) (kn) (mm) (mm) (mm) 40 B 70 P 60/5/380 60 36 70 70 40 3 576 380 60 B 70 P 60/5/390 60 36 70 70 60 48 576 400 00 B 70-36 70 70 00 80 576 450 00 B 50-5 50 95 00 80 83 580 00 B 35 P 60/9/870 60 7.5 35 40 00 80 60 870 6 00 B 450-3 450 85 00 80 968 085 00 B 550 P 60/30/40 3 550 30 00 80 968 40 0 B 35 P 60/9/870 7.5 35 40 0 96 60 870 0 B 450-3 450 85 0 96 968 085 60 0 B 550 P 60/30/40 3 550 30 0 96 968 40 0 B 650-45 650 75 0 96 30 430 60 B 35 P 75/4/870 7.5 35 40 60 8 60 885 60 B 450-3 450 85 60 8 968 00 75 60 B 550 P 75//50 3 550 30 60 8 968 55 60 B 650-45 650 75 60 8 30 445 0 B 35 P 85/4/900 7.5 35 40 0 68 60 905 0 B 450-3 450 85 0 68 968 0 85 0 B 550 P 85/ /70 3 550 30 0 68 968 75 0 B 650-45 650 75 0 68 30 465 50 B 550 P 95//300 3 550 30 50 00 968 305 95 50 B 650-45 650 75 50 00 30 500 300 B 550 P 05//330 3 550 30 300 40 968 330 05 300 B 650-45 650 75 300 40 30 50 6 0 0 4 4 Characteristics of ong od Insulators with Clevis and Tongue Couplings "C" according to the Standard IEC 60433 (998) and according to the former German Standard DIN 48006 / Part Designation Core Highest Standard Wet Specified outine Minimum Maximum Standard according according diameter system lightning power mechanical mechanical nominal nominal coupling to to former d voltage impulse frequency failing test creepage length size (con- Um withstand withstand load load distance necting bolt voltage voltage (6 mm/kv) diameter) d IEC 60433 DIN 48006/ (mm) (kv) (kv) (kv) (kn) (kn) (mm) (mm) (mm) 00 C 70-36 70 70 00 80 576 475 00 C 50-5 50 95 00 80 83 605 00 C 35 G 60/4/860 60 7.5 35 40 00 80 60 900 9 00 C 450-3 450 85 00 80 968 0 00 C 550 G 60/30/70 3 550 30 00 80 968 70 0 C 35 G 60/9/900 7.5 35 40 0 96 60 905 0 C 450-3 450 85 0 96 968 0 60 0 C 550 G 60/30/70 3 550 30 0 96 968 75 9 0 C 650-45 650 75 0 96 30 465 60 C 35 G 75/4/900 7.5 35 40 60 8 60 90 60 C 450-3 450 85 60 8 968 35 75 60 C 550 G 75//70 3 550 30 60 8 968 90 60 C 650-45 650 75 60 8 30 465 0 C 35 G 85/4/940 7.5 35 40 0 68 60 940 0 C 450-3 450 85 0 68 968 55 85 0 C 550 G 85//30 3 550 30 0 68 968 30 0 C 650-45 650 75 0 68 30 500 50 C 550 G 95//340 3 550 30 50 00 968 335 95 50 C 650-45 650 75 50 00 30 530 300 C 550 G 05//370 3 550 30 300 40 968 365 05 300 C 650-45 650 75 300 40 30 560 9 5 PAGE 8 PAGE 9