1. Introduction Communication in Substation



Similar documents
1. Communication Network Requirements

IEC 61850: Communication Networks and Systems in Substations

Substation Automation based on IEC 61850

ISIO 200. Binary Input/Output (I/O) Terminal with IEC Interface

My first Hirschmann: The SPIDER family of switches.

Substation Automation Systems. Nicholas Honeth

Substation Communications Design - Legacy to IEC 61850

Real-time Video Monitoring Increases the Efficiency of SCADA Process Management

Automation Unit TM 1703 ACP Flexible automation and telecontrol

FIBER OPTIC APPLICATION IN A PROFIBUS NETWORK

Connectivity solutions for transport automation

OPTICAL FIBER repeaters/ isolators

B5-103 DESIGN OF IEC BASED SUBSTATION AUTOMATION SYSTEMS ACCORDING TO CUSTOMER REQUIREMENTS

M-series Virtual I/O Module 2

Technical Specification Of Substation Protection & Control System with IEC BHEL s Perspective

Siemens ENEAS solutions for substation automation and protection

Arc Terminator Active Arc-Resistant Switchgear

Permissible ambient temperature Operation Storage, transport

METAL-CLAD AND METAL-ENCLOSED SWITCHGEAR 3.6KV~40.5KV. tgood.com. Energy. Fast.

TRACTION NETWORK MONITORING AND PROTECTION SYSTEM SMTN-3 CITY ELECTRIC TRANSPORT RAILWAYS METRO INDUSTRY

Waveguide Access Point WGA631. Product Guide

SICAM PAS - the Key to Success Power Automation compliant with IEC and your existing system

EVALUATING INDUSTRIAL ETHERNET

Application Note: Modbus/RS485 Wiring for Conext Core XC Series Inverters

Using Industrial Ethernet Switches to Assure Maximum Uptime White Paper

PCS0100en Persy Control Services B.V. Netherlands

(PREVIEW) Indian Standard COMMON SPECIFICATION FOR HIGH-VOLTAGE SWITCHGEAR AND CONTROLGEAR STANDARDS

Type: EASY719 DC RC Article No.: Ordering information Relay outputs Quantity 6 Power supply V DC 24 V DC. Description

New Technologies for Electric Power Distribution Systems

MGL Avionics CAN bus interface for Trig Avionics TT21/TT22 transponders

Table of Contents. TransformerIQ FAQs 1

Industrial IT for Substation Automation & Protection


Linear Motion and Assembly Technologies Pneumatics Service. Industrial Ethernet: The key advantages of SERCOS III

Square D Model 6 Motor Control Centers

Programmable set for Ethernet Modbus/TCP in IP67 TI-BL67-PG-EN-2

Understanding Device Level Connection Topologies

RENEWABLE ENERGY SUBSTATIONS SOLAR PHOTOVOLTAIC AND WIND POWER. tgood.com. Energy. Fast.

Voltage Regulator SPAU 341 C. Product Guide

Protection and Substation Automation. Training Programmes

Easily connect your switchboards to facility management solutions

Substation Automation Using IEC61850 Standard

Communicate and view data from meters with one simple device

M-series FOUNDATION Fieldbus I/O

DIGITAL CONTROL SYSTEM PRODUCT SOLUTIONS

ELECTRICAL ENGINEERING DESIGN CRITERIA APPENDIX F

INDUSTRIAL AUTOMATION EQUIPMENT EDITION

Substation Automation and Smart Grid

TM7BDM8B expansion block - TM7 - IP67-8 DI/DO - 24V DC A - M8 connector

Rack mounted telephone- and leased line modem for industrial applications

Straton and Zenon for Advantech ADAM Copalp integrates the straton runtime into the ADAM-5550 device from Advantech

Provides one channel for Ethernet over existing

GROUP OF SPANISH ELECTRICITY COMPANIES FOR STUDIES ON IEC 61850

Power Supply Unit, Primary Switched, Narrow Design MINI-PS-12-24DC/24DC/1

SCADA Systems Automate Electrical Distribution

SCADA Questions and Answers

Trip circuit supervision relay. Type RXTCS

AUTOMATIONWORX. Seamless system technology from the remote control station to the control center

ABB PSPS Erich Steinmann; Generator control-2013

APC Matrix-UPS 5kVA 208V/240V In 120/208/240V Out

ENERGY SOLUTIONS RESIDENTIAL STORAGE BATTERY SYSTEM

Telephone- and leased line modem for industrial applications TD-36

RM4TG20 three-phase network control relay RM4-T - range V

S-series SQ Controller

Basics in Energy Information (& Communication) Systems Substation Automation

Industrial 10/100/1000BASE-T to 100/1000BASE-X SFP Media Converter

How to Prevent Power Surges: The Leading Cause of Serial Device Server Failures

Re-defining the utility-scale inverter

Current valve. for AC 24 V pulse/pause control of electrical loads up to 30 kw

AUTOMATIC TRANSFER SWITCH. Changeover Type from 250A to 2500A

Introduction to PROFIBUS and PROFINET

TX OPEN RS232/485 module

Redundant Gigabit Backbone Adds Speed and Reliability to Industrial Networks

emobility WAGO Leading the Charge

Grid Automation Products. SAM600 Process Bus I/O System Cyber Security Deployment Guideline

1. Cyber Security. White Paper Data Communication in Substation Automation System (SAS) Cyber security in substation communication network

Gain energy insight and control with PowerLogic. PowerLogic EGX300 integrated gateway-server

PROCESS AUTOMATION. OPERATING AND MONITORING IN HAzARDOUS AREAS AND INDUSTRIAL ENVIRONMENTS PRODUCT OVERVIEW

Communication Unit 560CMU05 Data sheet

RM17TE V AC. Main. Product or component type. Product specific application. Relay monitored parameters 250 V DC 5 A DC

SUGGESTED SPECIFICATION for Series 185 Service Entrance Rated Automatic Transfer Switches

Disturbance Recoder SPCR 8C27. Product Guide

CONTROLS DATA MANAGEMENT PROCESS AUTOMATION EUROCUBE. General purpose single phase thyristors and solid state relays Product data.

8-Port PoE Network Switch

Provides one channel for Ethernet over existing

Hirschmann Networking Interoperability in a

Circulating Current Relay. Type IRXm

WEB log. Device connection plans

Substation Automation Products Relion 670/650 series IEC and ANSI Hardware

Process modules Digital input PMI for 24 V DC inputs for 120 V AC inputs

User s Manual Before using the inverter, you need to read and save the safety instructions.

Plant automation and telecontrol in one system. SIMATIC PCS 7 TeleControl SIMATIC PCS 7. Answers for industry.

PROFIBUS/PROFINET System design

FFI. Advances in Medium and Low Voltage Power Distribution ESS Metron Expo and Technical Seminars. Presented By: Greg Pelster & Robert Schmid

RS485 & RS422 Basics

Standards in Marine Power Systems. APEC 2014 Session IS2.1 Power Electronic Standards Roger Dougal University of South Carolina Columbia, SC 29208

Grid Automation Products. MicroSCADA Pro for substation automation

IEC SCL - MORE THAN INTEROPERABLE DATA EXCHANGE BETWEEN ENGINEERING TOOLS

SURGE PROTECTIVE DEVICES

RM35UA13MW. range V. Main. Product or component type. Relay monitored parameters

Transcription:

WP 1004HE Part 1 1. Introduction Communication in Substation White Paper Data Communication in Substation Automation System (SAS) Introduction of modern substation communication 1.1 What is the Substation Automation System (SAS)? An electrical substation is a subsidiary station of an electric power generation, transmission and distribution system. Voltage will be transformed in SAS between power generation and transmission from a lower level (e.g. 11 KV) to higher a level (e.g. 110 KV, 220 KV, 500 KV, 715 KV or even 1000 KV). Power will be transmitted over long distances to another SAS where electricity will be transformed from high voltage back to low voltage (e.g. 100 KV, 10 KV, 1 KV or 220 V) for power distribution and consumption. The substation is the node in the electrical power network. Functions of substation are control and monitoring of the switch yard, recording, protection of the power equipment, revenue metering and automation functions for energy management and assert management. Conventional substation is composed with interlocking logic, RTU (Remote Terminal Unit), Relays, conventional switchgear and CT/PT (current/potential transformers). Each component is hardwired connected with parallel Cu wires. Table of Contents 1. Introduction Communication in Substation... 1 1.1 What is the Substation Automation System (SAS)?... 1 1.2 What is the Data Communication in SAS?... 2 1.3 Which Standard and Protocols are Used?... 2 1.4 What is IEC 61850?... 2 1.5 What is the Benefit of Using IEC 61850?... 3 2. Environmental Conditions... 3 2.1 Why Should we be Concerned About Environmental Conditions?... 3 2.2 Which Standards Should be Applied?... 3 2.3 What are the Environmental Conditions of a Substation?... 3 2.4 Summary and Outlook... 4 Annex: Further Support... 5 Technical Questions and Training Courses... 5 Belden Competence Center... 5 Modern substation automation is structured in three basic levels. The station level provides an overview across the whole station and is located in a shielded control room. Station level includes HMI Workstation, Master Station Computer, Backup Station Computer and GPS (Global Positioning System) receiver, etc. The bay level conducts maintenance work only within one bay and it is usually close to the switchgear. Bay level includes protection and control IEDs (intelligent electrical devices) of different bays such as circuit breakers, transformers, and capacitor banks. Equipment in bay level and station level are called secondary equipment. Process level provides the interface between the substation automation system and the switchgear. Process level includes switchyard equipment (also primary equipment) such as CTs/PTs, remote I/O, actuators, merging units etc. Figure: IEC 61850 Substation Automation System

1.2 What is the Data Communication in SAS? Substation data communication system plays a critical role in the real time mission critical operation of substation automation system. All secondary equipment within a substation is interlinked with communication buses. In conventional substation, legacy communication devices typically relied on one-way communication. Serial communication buses or proprietary communication media with associated protocols are used for local HMI, as well as for remote SCADA (Supervisory Control and Data Acquisition) communication. Modern communication in substation is data transmission inside and between station level, bay level and process level. The data information includes control, report, log GOOSE, SV, etc. Communication between these 3 levels is called vertical communication and connected by high-speed Ethernet station bus and process bus. Station bus facilitates communication between station level and bay level. Process bus will be used for time critical messages between process level and bay level. Most of the substation protection and control functions will rely on the performance of the process bus. Communication within one level is horizontal communication. In station levels, the time based data from multiple bays or substation level database will be analyzed and processed. The control commands for the primary equipment (e.g. circuit breakers) will be submitted and data like voltage, current and power factor will be collected. In bay level, protection unit and control unit collect data from bays and perform actions on the primary (e.g. power circuit) equipment. In process level, performance and condition information are read from essential station equipment. Control commands from bay level will be received and executed in the equipment at the process level. 1.3 Which Standard and Protocols are Used? Communication protocols define the architecture of substation automation communication systems. They determine the way of information traffic between control stations, IEDs and other communication devices. Generally there are 3 different standards categories for substation communication: Proprietary/vendor specification, e.g. UCA and DNP3, etc. National standard, e.g. IEEE 1613, etc. International standard, e.g. IEC 60870-5- 101/104, IEC 60870-6-TASE.2, IEC 61850, etc. Communication networks in substations will often have lower-level data link, physical layer protocols and multiple application layer protocols running on top of TCP/IP. In the past and present, there are over 50 communication protocols for legacy substation automation systems. These include Modbus TCP, ProfiNet, EthernetIP, OPC-DA, and LON for example. Many of these topologies are vendor specified and have serial interface, low bandwidth, limited network devices, serial interfaces and inflexible data, etc. Their communication architecture does not fit to the corporate communication technology and are not able to expend the network. Most representative protocols are DNP3 and IEC 60870-5-104. Both of them are master/slave based fieldbus communication and can only be implemented till station level and bay level. Nowadays many substation vendors are moving away from serial to Ethernet based IEC 61850 which is a client/server communication standard. It fully supports the interoperability among IEDs supplied by different vendors in the substation and can be applied also in process level in substation automation. 1.4 What is IEC 61850? IEC 61850 is a standard for communication networks and systems for power utility automation and is being produced by IEC Technical Committee 57 Working Groups 10. It is developed based on Utility Communications Architecture 2.0 (UCA2.0) which is based on the Manufacturing Message Specification (MMS). IEC 61850 is a lower-layer object-oriented protocol being implemented over TCP/IP and Ethernet networks. It defines a vendor independent communication infrastructure allowing seamless IEDs integration. Compare to DNP3 or IEC 60870-5-104, IEC 61850 is not only another way of providing the same functions as a traditional SCADA protocol, it also provides information modes, configuration languages and abstract services in substation communication. Main features of IEC 61850 are as follows: It translates all in the information in the real substation into information models in the form of standard naming conventions structures and formats for easy information management. It provides Abstract Communication Service Interface (ACSI) and makes it possible for applications and databases to be unchanged with changes in the communication protocols and media. It standardizes a Substation Configuration description Language (SCL) to describe substation topology, information models, binding to process, communication and data flow, etc. SCL can be used to exchange an IED s communication configuration information and software from different manufacturers. It provides communication protocols of TCP/IP based SCADA, real time Generic Object Orientated Substation Event (GOOSE) and Generic Substation Status Event (GSSE) and real time sample measured value (SMV). GOOSEs support system protection applications and run directly over Ethernet. It defines process bus which is supported by GOOSE and can minimize substation wiring requirements in the yard by converting data of CTs/PTs to digital information. 2

1.5 What is the Benefit of Using IEC 61850? IEC 61850 is the comprehensive standard for all communication functions in utility applications. It is non-proprietary technology with multiple vendors and provides interoperability between devices and application functions through standardized data models and information exchange. It realizes a highly flexible configuration of communication networks and can greatly simplify substation automation architecture, optimize the selection of devices for curtain application and increase efficiency. IEC 61850 is a future proof standard for safe investment. By implementing IEC 61850, the application model and communication stack can be separate. The applications can be modified and extended without changing of the communication stack. It meets utilities requirements to combine products from a variety of manufactures for long term system exchangeability of equipment and expandability. 2. Environmental Conditions 2.1 Why Should we be Concerned About Environmental Conditions? Communication devices like Ethernet Switches, IEDs and MUs (Mergin Unit) in substation are installed normally in harsh and critical environmental conditions. Equipment in substation like transformer, bay and other electrical devices will create themselves electric fields and magnetic fields. Electrostatic discharge, vibration and high energy power surges will occur during the substation operation. In order to keep highly precise, real-time communication and avoid catastrophic failures, power substations require necessary resistance of the communication systems against environmental influences of mechanical, thermal, electromagnetic compatibility or other harsh operating conditions. 2.2 Which Standards Should be Applied? The general environment requirements for the industrial environment are considered not sufficient for substations. Communication devices in substation must be in compliance with environmental conditions described in following standards: IEC 61850-3:2002 IEC 61850-3 is the main standard for substation environmental conditions. It lists out the environmental requirements such as supply voltage, EMI immunity, temperature, humidity, barometric pressure, mechanical, seismic, pollution, and corrosion, etc. Many other IEC standards like IEC 60870-2(environmental climatic conditions) and IEC 60694 (high voltage area application) are referred in IEC 61850-3. IEEE 1613 IEEE 1613 presents IEEE standard environmental and testing requirements for communications networking devices in electric power substations. Communication devices can be specified here in terms of temperature and humidity, power supply, high voltage resistance, EMC and radiated immunity, vibration and shock, or altitude, etc. These two standards define the overall environmental requirements in substations, no matter indoor or outdoor, or how critical or uncritical situation. Devices mounted in different situations in substations can meet different classes of requirement in the standard. End user should clarify the class level of the devices even the devices are compliance with these standards. 2.3 What are the Environmental Conditions of a Substation? EMI Immunity In substations various types of Electromagnetic interference will be generated by electromagnetic disturbances, by lightning and switching surges, by discharges and strokes of electricity, by damped oscillatory wave or burst, etc. Communication equipment should be able to withstand these EMI phenomena. Two classes of EMI immunity for communication devices are defined. In class 1, devices may experience some data errors, loss, or delays under EMI stress conditions. Class 1 is adequate for network supervision. In class 2, devices must not experience any data errors, delays or loss under EMI stress conditions. Class 2 is essential for IED to IED communication in substations. Climatic Conditions Mounted location of communication devices in substation could be in climate control room, in outside control cabinet or on the open explored bay itself. The surrounding temperature range during the operation could vary from very low degree to very high degree. Therefore the temperature requirement is also different. According to IEC 60870-2-2, 4 following temperature classes are defined for substation communication devices: A*: air conditioned locations B*: heated or cooled enclosed locations C* sheltered locations D* outdoor locations Substation end user must be aware of the real surrounding temperature requirements and select corresponding communication equipment according to different temperature classes. Hirschmann switch products are typically specified for sheltered locations C3 and specified for a long lifecycle without building fan design. In sheltered locations, the devices must meet up to 100% rel. humidity requirement. Hirschmann switches are available with conformal coated PCBs to enhance the resistance against humidity. For instance, products with coating are required in high humidity application locations like seaside or places with heavy fog or high temperature variations. Coating is also required sometime under the Industrial clean air condition in substation. 3

Supply Voltage Supply voltage of substation equipment may be different in different countries. Preferred DC power supply voltage values are 220VDC, 110VDC, 60VDC, 48VDC, 24VDC or 12VDC. Normally, a big standby battery should be equipped to provide power in case of voltage failures and continually charged and discharged from the substation network. The voltage of standby battery should be the same as those of IEDs in substation, e.g. 110VDC. Many manufactures provide communication devices with redundant power supplies and hot-plug power modules to enhance the high reliability of product and accordingly network communication. When one power supply fails, another power supply will take over the energy supply. The hot plug power module can be exchanged during the application mode. Mechanical Requirement Four different classes of mechanical requirement are specified in IEC 60870-2-2: Class Am for light installation installed in locations where no significant sources of vibration and shock are present, as in control rooms and residential areas. Class Bm for normal installation installed in locations with vibrations of low significance and shocks, as remote terminals units in power plants, substations and industrial areas. Class Cm for severe installation installed in locations with significant vibrations and shocks, as industrial areas with machines or nearby passing vehicles. Class Dm for critical installation installed in locations where the level of vibrations and shocks is high as in close to heavy machines or in the proximity of reach of traffic of heavy trucks. Normal locations of communication equipment in substations are in class Am and Bm. Hirschmann Ethernet Switches are in compliance with class Bm. Barometric Pressure Communication devices will be installed in the substation located in different altitude. Normally IEC 61850-3 defines an application altitude range from -400 meters (with 106 kpa) to 3000 meters (with 70 kpa). If communication devices are used in regions with higher altitude, heat dissipation of the device is limited because of the thinner air. A derating of the maximum permissible ambient temperature must be considered in this situation. For the substation applications whose altitude is higher than 2000 meters, the isolation distance in the switch electricity must be wider than the normal distance to guarantee the correct dielectric strength. 2.4 Summary and Outlook The communication of devices might be broken down or destroyed by different environmental disturbances. Most critical environmental conditions in substation are EMC and climatic conditions. Thus, as mission-critical components, extremely robust, rugge-dized communication devices are required to ensure efficient signal transmission possibilities. There is no fixed environmental condition requirement for the communication devices in a given substation application. Manufacturer can declare their products according to the different levels in the standard. In order to ensure high communication reliability, customers may determine which classes are required for product according to real application requirement and select equipment accordingly. The Ethernet switch is installed in the same place as the control or protection IEDs and is essential information Hinge in the communication network in the substation. It must go through the same tests and comply a with the same standards as IEDs and Mus. Hirschmann has wide product portfolio for substation communication application under the standards IEC 61850 and IEEE 1613. Special requirements of substation environmental conditions can be covered by Hirschmann Ethernet switches. References: 1. IEC 61850 Communication Networks and systems in substations, IEC standard in ten main parts, 2002 2. IEEE 1613-2009 IEEE Standard Environmental and Testing Requirements for Communications Networking Devices Installed in Electric Power Substations 3. Klaus P Brand, Volker Lohmann, Wolfgang Wimmer, Substation Automation Handbook, 2003 4. D. Baigent, M. Adamiak and R. Mackiewicz, IEC 61850 Communication Networks and Systems In Substations: An Overview for Users. SIPSEP 2004, at http://www.gedigitalenergy.com/multilin/journals/issues/spring09/iec61850.pdf 5. Hirschmann White Paper, Ethernet Enables The Smart Grid, at http://www.belden.com/docs/upload/ethernet_smart_grid_wp.pdf 6. Hirschmann Service and support: http://www.beldensolutions.com/de/service/index.phtml 4

Appendix: Further Support Technical Questions and Training Courses In the event of technical queries, please contact your local Hirschmann distributor or Hirschmann office. You can find the addresses of our distributors on the Internet: www.hirschmann.com Our support line is also at your disposal: Tel. +49 (0)1805 14-1538 Fax +49 (0)7127 14-1551 Current training courses for technology and products can be found under http://www.hicomcenter.com. Consulting Train ng i Belden Competence Center In the long term, excellent products alone do not guarantee a successful customer relationship. Only comprehensive service makes a difference worldwide. In the current global competition scenario, the Belden Competence Center is ahead of its competitors on three counts with its complete range of innovative services: Consulting incorporates comprehensive technical advice, from system evaluation through network planning to project planning. Training offers you an introduction to the basics, product briefing and user training with certification. Support ranges from the first installation through the standby service to maintenance concepts. Support With the Belden Competence Center, you do not have to make compromises. Our client-tailored package enables you to choose the service components you want to use. Internet: http://www.hicomcenter.com 6 Phone +49 (0)7127/14-1809 Copyright 2012, Belden Inc. www.hirschmann.com WP 1004HE 07.12