Speed Control Relays SX2



Similar documents
Solid State Timers Type F

Series /16 DIN Multi-Mode Bar Graph Display Timer TIMERS PRODUCT HIGHLIGHTS

Digital Pressure Measuring Instrument MDR480

ACS-30-EU-EMDR-10-MOD

Power Supply and Indicator Unit Type Fig. 1 Type Mounting and Operating Instructions EB 9539 EN

Preset Counter signo 721

Control Devices Catalogue. Control Devices. Preferred and Standard Products

Inductive Sensors Single or Dual Loop Detectors Type LD with teach-in

80 Series - Modular timers 16 A. Features

Intrinsically Safe Barrier Relays NY2 and 8501TO

W 36: Mastering complex tasks reliably

Centro-Matic Automatic Lubrication Systems System Controls

Analogue Input, 4-fold, MDRC AE/S 4.1, GH Q R0001

Multifunction devices

PD30ETB20xxIS. Photoelectrics, Background Suppression reflective with IR light. Main features. Description

FACTORY AUTOMATION. Manual. Speed Monitor KHU8-DW-1.D

Quick Connect. quick - simple - efficient.

SX460. Generator Automatic Voltage Regulator Operation Manual

IO-RM3 3-Stage Relay Module

SKR - industry relay

VEO. V4PF480Y/277VSYTK02 Art.Nr.: V4PF480Y/277VSYTK02P Art.Nr.: TECHNICAL DATA

ABB 1. Three-phase monitoring relay CM-PFS. Data sheet. Features. Approvals. Marks. Order data. Order data - Accessories. Application.

1115 4G SERIES GOVERNOR ma ANALOGUE DIGITAL SPEED SETTING

D.C. Motors. Products and specifications subject to change without notice.

Capacitive Prox E2K-X

VIBRATION MONITORING OF FANS INSTALLED IN ROAD TUNNELS

RM17TE V AC. Main. Product or component type. Product specific application. Relay monitored parameters 250 V DC 5 A DC

Safety Relays ESM/ESM-F

Type: DILM115(RAC240) Article No.: Sales text Contactor,55kW/400V,AC operated. Ordering information

Single Channel Loop Detector

CENTERLINE Motor Control Centers Bulletin 2100 Smoke Detector Unit

Safety technique. Emergency stop module BO 5988 safemaster

Contents. Document information

Incremental Rotary Encoder E6B2

Voltage monitoring relays CM-ESS.2 For single-phase AC/DC voltages

Your Advantages For safety application up to PL e / Cat. 4 e.g. SIL 3 Manual or automatic start * see variants. Applications.

Specifications for EM VDC 4 In/4 Out and EM VDC 4 In/4 Relay Out

Voltage Regulator SPAU 341 C. Product Guide

Three-phase monitoring relay CM-PFE

Contactless Encoder RI360P0-QR24M0-INCRX2-H1181

Inductive Proximity Sensors

Shutter Actuator Standard, 4-fold, 230 VAC, MDRC RA/S , GH Q R0111. ABB i-bus EIB

Universal Voltage Terminal Photoelectric E3JM

Absolute Rotary Encoder E6CP

Throughbeam photoelectric sensors. Dimensioned drawing. Electrical connection

Process modules Digital input PMI for 24 V DC inputs for 120 V AC inputs

SUBJECT: How to wire a motor starter Number: AN-MC-004 Date Issued: 2/08/2005 Revision: Original

PSR The compact range Description

HERZ-Thermal Actuators

mecotron Safety relay ESTOP-2 For emergency stop monitoring

DORMA MODEL PS-406BB POWER SUPPLY INSTALLATION INSTRUCTIONS

Operating Manual for the Electronic Built-in Interval Timer. Micro II (Countdown Timer)

Clear Glass Sensor. Ordering Information E3S-CR67/62. Optimum Sensor for Detecting Transparent Glass and Plastic Bottles

Tool Turrets and Tool Discs

A1000 Cheat Sheet (Open Loop Vector)

ABB i-bus EIB Shutter Actuators JA/S , JA/S , JA/S , JA/S M, JA/S M, JA/S

LUT Luminescence scanners: Seeing what no-one else can

DS 600. A contact free flux gate based current measurement sensor 600A rms

Automation System TROVIS 6400 TROVIS 6493 Compact Controller

Voltage monitoring relays CM-ESS.2 For single-phase AC/DC voltages

Solid-State Timer H3G

RISH EM 3490 DS Dual Source Energy Meter RISH EM 3490 DS. Application : Product Features:

Three-phase monitoring relays CM-PSS CM-PSS.31 and CM-PSS.41

ABB 1 NEW. Three-phase monitoring relay for grid feeding CM-UFS.1. Data sheet. Features. Approvals. Marks. Order data. Order data - Accessories

Type: EASY719 DC RC Article No.: Ordering information Relay outputs Quantity 6 Power supply V DC 24 V DC. Description

TLK 48 MICROPROCESSOR-BASED DIGITAL ELECTRONIC REGULATOR

New XUY roller sensors

CONFIGURABLE SAFETY RELAYS

GENERATOR START CONTROL MODULE - MINI (2 Wire to 3 Wire)

RM35UA13MW. range V. Main. Product or component type. Relay monitored parameters

Electronic timer CT-VBS OFF-delayed without auxiliary voltage, for DC contactors Data sheet

DRTS 33. The new generation of advanced test equipments for Relays, Energy meters, Transducers and Power quality meters

Thru-Beam 80 to 320 mm 0.05 to 0.08 mm

Telefon (+45) Telefax (+45) Installation and operating manual

Smart DeviceNet Remote I/O Terminals

AUTOMATIC TRANSFER SWITCH. Changeover Type from 250A to 2500A


RM4TG20 three-phase network control relay RM4-T - range V

GLOLAB Two Wire Stepper Motor Positioner

Electronic Timer - Series Micon 175

3PH2 or 3PHE 3 Phase Control Board

Switch Actuator, 8-fold, 10 A, MDRC AT/S , GH Q R0111

*.ppt 11/2/ :48 PM 1

Agilent AEDB-9140 Series Three Channel Optical Incremental Encoder Modules with Codewheel, 100 CPR to 500 CPR Data Sheet

Thermistor motor protection

Electronic overload relay EF65, EF96 and EF146

Power Supplies 3. SDN-P DIN Rail Series

Duct Humidity Transmitter

Electric Rotary Actuator - On/Off or programmable control actuator

Bulletin 150 SMC Flex Smart Motor Controller Specifications

MCR-VDC-UI-B-DC. Voltage Transducer for DC Voltages. INTERFACE Data Sheet _en_01. 1 Description

SINEAX U553 Transducer for AC Voltage

4 A CAPACITY, THE VARIETY OF CONTACT ARRANGEMENTS FEATURES

38 SERIES. Relay interface modules A. EMR Electromechanical Relays. Common features. SSR Solid State Relays. 6.

Proximity Sensors Inductive Thermoplastic Polyester Housing Types EI, DC, M 12, M 18, M 30

Meter Relays. 077 Series Analogue Meter Relays. Features. Applications

W150: Miniature photoelectric switch series with completely integrated electronics

Automotive Sensor Simulator. Automotive sensor simulator. Operating manual. AutoSim

Transcription:

SX2 File 850 CONENS Description.....................................................Page General Information................................................ 2-3 SX2DV General Information........................................... 4 SX2DV2 General Information........................................... 5 Wiring Diagrams, Approximate Dimensions and Weights...................... 6 Ordering Information and Specifications................................... 7

General Information Properly applied, motion detection devices can: Decrease downtime Reduce maintenance Minimize product damage As production speeds increase and more sophisticated assembly lines or conveyors are used to move products, there is a greater need to monitor and control the speed. his is particularly true since there are more motors, transmissions and belts that can fail, causing downtime. his motion detection can be done in a number of ways, including: A switch or sensor and an off-delay timer (See 9050 JCK imers, Catalog 9050C960) A self-contained motion detector (See Sensors, Catalog 9006C970, page 02) A switch or sensor and a speed control relay (described in this catalog) Underspeed Control Underspeed control is used to sense when a shaft or conveyor is going slower than the set speed. When the speed exceeds the set speed, the output contacts change state. hey remain energized until an underspeed (slow speed) is detected, or voltage is lost to the relay, then the output contacts change state, returning to their deenergized state. An underspeed relay can be used to detect slippage or breakage of a belt, chain, coupling, or archimedian screw. It can be used to signal the overloading of a grinder or mixer. It can also be used as part of a system to keep doors or gates from opening until moving parts on a machine or robot have stopped moving. Overspeed Control Overspeed control is used when a shaft or conveyor is going faster than the set speed. When the speed exceeds the set speed, the output contacts change state, and they can be used to sound an alarm or shut the machine down. hey will remain energized until the speed drops below the low speed setting, then changing state. An overspeed relay can be used to detect breakage of a belt or chain. It can also be used to sequentially start several conveyors. When the first conveyor reaches a preset speed, then the second conveyor is started, etc. 2 998 Square D All Rights Reserved /98

SX2DV General Information arget 0 Sensing face of detector Standard arget For Rotating Shafts A standard target covers a wide speed range and is suitable for use with most sensors. It is a rectangular piece of steel symmetrically mounted across the end of the motor shaft. he dimensions of the standard target are 7.9 in. x 3.5 in. x 0.08 in. (200 mm x 90 mm x 2 mm). 200 96 r 80 d o determine the maximum and minimum shaft speed which can be detected using the SX2DV00 or SX2DV03 and this standard target, use this formula: 90 I N m n N shaft speed m number of pulses per minute n number of targets (the standard target acts as two targets) he range of the SX2DV00 and SX2DV03 is from 2.2 to 6000 pulses per minute. n 2 if the standard target is used. N Max 6000 / 2 3000 rpm N Min 2.2 / 2. rpm Calculating Pulse Duration 60 ( l + d) ---------------------------- 2π N r l length of target d diameter of sensor N shaft speed r radius from center of shaft to sensor Using the standard target, a 8 mm sensor (for example, XSM8PA370) and a shaft speed of 725 rpm: 60 ( 90 + 8) ----------------------------------------------------- 6480 ---------------------- 0.0075 s 7.5 ms 2 3.4 725 80 866, 640 he pulse durations must be: greater than the SX2DV limit of 2.3 ms greater than the sensor s ON and OFF delays Calculating the Interval Between Pulses 60 ( ( 2π r n) ( l + d) ) ------------------------------------------------------------------ 2π r N l length of target d diameter of sensor N shaft speed r radius from center of shaft to sensor n number of targets 60 ( ( 2 3.4 80 2) ( 90 + 8) ) 8592 ---------------------------------------------------------------------------------------------- -------------------- 0.0099 s 9.9 ms 2 3.4 80 725 866,640 Setting and Adjustment o facilitate setup, a selection switch and two potentiometers are on the front of the relay.. Select the proper speed range for the SX2DV00 or SX2DV03 relay: 2.2 to 60 pulses per minute 0 22 to 600 pulses per minute 00 220 to 6000 pulses per minute 2. Adjust the Speed hreshold Potentiometer to the desired setting. 3. Adjust the Start-up ime Delay Potentiometer to the desired time delay. /98 998 Square D All Rights Reserved 3

SX2DV General Information Description of Operation Output Contact imed Contact LED Indicator Setting 0 Closed Open Energized De-energized On Off N-Pulses / Minute i i he SX2DV00 and SX2DV03 relays are used to compare the number of pulses per minute that are being detected to the pulses per minute setting on the relay (using the speed threshold potentiometer and the speed range selector switch). he pulses can be detected from a rotating shaft or from items moving down a conveyor line. As soon as power is applied to the relay power supply terminals, the timed contacts and output relay contacts close and the LED indicator comes on. o allow time for the system to attain the preset speed, a timed contact (internal or external) is used to keep the circuit energized for a preset time period (i). If the system is not up to speed by i, the relay will shut down the system or motor. If the preset speed is attained by the end of i, the output contact will remain closed. If the speed falls below the relay setting at any time after the i period is complete, the output contacts open, shutting down the system or motor. he LED indicator is illuminated while the output contact is closed. 2 3 0 +24V Ov Ov man auto SX2 DV 00 00 0 4 Volts a.c. OV 0 7 4 220 240 4 5 6 7 - Impulse input 2-24 VDC power supply inputs and proximity sensor connection 3 - Start-up interlocks 4 - Speed threshold potentiometer 5 - Speed range selector switch 6 - "Output relay energized" indicator 7 - Start-up delay potentiometer 8-0-220 VAC power supply inputs 9 - Relay outputs Pulse Detection he pulses can come from a number or sources. he most common are: 24 Vdc, 2-wire sensors 24 Vdc, 3-wire, PNP (sourcing) sensors Hard contacts (limit switches, photoelectric switches, etc.) 24 Vdc 2-Wire Sensor 24 Vdc 3-Wire PNP (Sourcing) Sensor Hard Contacts 8 9 - + e + - 0V manu auto 0V manu auto 0V manu auto imed Contact Source Scale for Start-Up Delay Potentiometer (7) Seconds 5 he i timed contact source is either internal or external. he internal source uses the potentiometer on top of the relay to set i. he external source uses a normally closed contact of an on-delay timer. 0 Internal Source Jumper External Source NCO 5 0V manu auto 0V manu auto A B C D E F G H J K L M 4 998 Square D All Rights Reserved /98

SX2DV2 General Information Setting and adjustment 2 3 4 5 0 +24V Ov Ov arm inv SX2 DV 200 00 0 4 Volts a.c. OV 0 220 7 240 4 0 00 90 80 70 60 50 40 6 7 8 9 - Impulse input 2-24 Vdc power supply inputs and proximity sensor connection 3 - External interlocking input 4 - External interlocking input (between terminals 3 & 4) 5 - Output relay inverting input (between terminals 3 & 5) 6 - High speed threshold setting potentiometer 7 - Speed range selector switch 8 - Output relay energized indicator 9 - Low speed threshold setting potentiometer 0-0-220 Vac power supply inputs - Relay outputs A B C D E F G H I J K L M Jumper Description of Operation he SX2DV200 and SX2DV203 relays compare the number of pulses per minute detected to the pulses per minute setting on the relay (set with the high speed threshold potentiometer, the speed range selector switch, and the low speed threshold potentiometer). he detected pulses can be from a rotating shaft or items moving down a conveyor line. Without inv Without inv is the most common mode of operation. here is no jumper between the +24 terminal and the inv terminal. When power is applied to the relay between the 0v terminal and either the 0/7 terminal or the 220/240 terminal, the output contact does not change state. When the detected speed reaches the high speed threshold setting, the output relay changes state (energizes). he output will remain energized until the detected speed drops below the low speed threshold setting. he low speed threshold is a percentage (00 to 30%) of the high speed threshold. the LED on top of the relay will illuminate whenever the relay is energized. With inv here is a jumper between the +24v terminal and the inv terminal. When power is applied to the relay between the 0v terminal and either the 0/7 terminal or the 220/240 terminal, the output contact changes state. When the speed being sensed reaches the high speed threshold setting, the output relay changes state (deenergizes). he output will remain deenergized until the detected speed drops below the low speed threshold setting. he low speed threshold is a percentage (00 to 30%) of the high speed threshold. he LED on top of the relay will illuminate whenever the relay is energized. 0V arm inv Pulse Detection he pulses can come from a number or sources. he most common are: 24 Vdc, 2-wire sensors 24 Vdc, 3-wire, PNP (sourcing) sensors Hard contacts (limit switches, photoelectric switches, etc.) N-Pulses / Minute Setting 24 Vdc 2-Wire Sensor 24 Vdc 3-Wire PNP (Sourcing) Sensor Hard Contacts 0 - + e + - RELAY OUPU Without INV With INV Energized De-energized Energized De-energized N-Pulses / Minute 0V arm inv 0V arm inv 0V arm inv If a normally closed timed open contact is wired between arm and 0v as shown below, the output contact will energize immediately, not waiting for the speed to reach the high speed threshold. his can be used to keep the relay energized until the system is up to speed. Setting 0 NCO "ARM" Contact Normally Closed imed Contact Closed Open Output Relay without "INV" Energized De-energized ime 0V arm inv /98 998 Square D All Rights Reserved 5

Wiring Diagrams and Approximate Dimensions SX2DV00 amd SX2DV03 Wiring Diagrams Using Internal imed Contact Source Using External imed Contact Source 0V Volts, AC 0 220 7 240 4 4 0V Volts, AC 0 220 7 240 4 4 L L2 L L2 Stop Start M M OL Stop Start M M OL SX2DV200 and SX2DV203 Wiring Diagram 0V Volts, AC 0 220 7 240 4 4 L L2 Stop Start M M OL Approximate Dimensions 2.63 (67).73 (44) 4.37 () Dimensions are in inches (millimeters). Weight:.3 oz (0.32 kg) 6 998 Square D All Rights Reserved /98

Ordering Information and Application Data Description ype of Action hreshold Range (pulses per minute) Underspeed Stopping 2.2 to 6000 Underspeed and Overspeed Control ype of Input PNP sensor or hard contact Supply Voltage Catalog Number 24 Vdc SX2DV03 0/220 Vac SX2DV00 Stopping 24 Vdc SX2DV203 PNP sensor or hard 3.2 to 8000 Enabling contact 0/220 Vac SX2DV200 Specifications AC power supply 0 Vac (-5%, +0%) 220 Vac (-5%, +0%) 50/60 Hz 2 VA 24 Vdc (9.2 to 27.6 Vdc) 2 W 5 A Frequency Consumption DC power supply Power consumption Related relay thermal current Ambient temperature Operation Storage Housing protection NEMA (IP20) Repeat accuracy (constant voltage) ± % hermal drift (constant voltage) ± 0.4% per C Voltage drift (constant temperature ± 0.5% Input specifications Sensor supply 24 Vdc ±5% Minimum input resistance 2.2 kω Minimum input voltage (on) Minimum input voltage (off) Minimum duration of the signal Minimum interval between signals Maximum line resistance -4 to 2 F (-20 to +50 C) -40 to +85 F (-40 to +85 C) V 4 V 2.3 ms 2.3 ms 200 Ω ypical input current 0 ma Maximum pulses per minute 3,000 Controllable speed range SX2DV 00/03 SX2DV 200/203 Output relay specifications 2.2 to 6000 pulses per minute 3.2 to 8000 pulses per minute Voltage 48 Vac 0 Vac 220 Vac 24 Vdc 48 Vdc Maximum current (IEC) 4 A 2 A A Maximum power NEMA rating LED 200 VA B50 Illuminated when relay is energized A L/R < 5 ms 0.5 A L/R < 5 ms /98 998 Square D All Rights Reserved 7

Square D Company 800 Hwy 64 East Knightdale, NC 27545 (99) 266-367 Square D and are registered trademarks of Square D Company. Catalog No. 850C9703 January 998 998 Square D All Rights Reserved. Replaces 850C960 dated /96.