289 Series Spring-Loaded Relief Valves



Similar documents
1805 Series Relief Valves

Types 66R and 66RR Low-Pressure Relief Valves

1301 Series High-Pressure Regulators

Type EZL Pressure Reducing Regulator for Low Differential Pressure Applications

167D Series Switching Valves

Type 99 Pressure Reducing Regulator

Type HSR Pressure Reducing Regulator for Residential, Commercial or Industrial Applications

Type 119 Control Valve

Type EZR Relief Valve or Backpressure Regulator

Type 92S Pilot-Operated Steam Regulator

SLAM-SHUT VALVE. Type OSE. Europe, Middle East, Africa and Asia Pacific Documents Only. Process Management TM

EZR Series Pressure Reducing Regulator

67C Series Instrument Supply Regulators

Baumann Way Bronze or Stainless Steel Control Valve

Type 310A-32A Pressure Reducing Regulator and Type 310A-32A-32A Working Monitor Regulator

Baumann Little Scotty Bronze Control Valve

Fisher 657 and 667 Diaphragm Actuators

Fisher 377 Trip Valve

Type 99 Pressure Reducing Regulator

Product Manual. CVS Type 67AFR Filter Regulator. Introduction. Installation. Description

1800C and 1800C-HC Series Service Regulators. Technical Bulletin

Baumann Mikroseal Control Valve

MODEL LP 225LP2 225LP4 Safety Relief Valves

Baumann Flexsleev Sanitary Control Valve

Vacuum Control. Vacuum Applications. Vacuum Regulators. Vacuum Breakers (Relief Valves) Vacuum Control Devices. Vacuum Terminology

Fisher 377 Trip Valve

M Series Manual Handwheel Gear Actuators for Fisher Butterfly Valves

Commercial & Industrial Propane Regulators and Meters

automatic Changeover regulators and systems manifolds/changeover regulators

Fisher ENVIRO-SEAL and HIGH-SEAL Packing Systems for Sliding-Stem Valves (Live-Loaded)

Fisher CV500 Rotary Globe Control Valve

Fisher 2625, 2625SST, and 2625NS Volume Boosters

Fisher D3 Control Valve

BERMAD Waterworks. Pressure Relief/Sustaining Valve. 700 Series. Model 730. Features and Benefits. Major Additional Features

Shut-off & Lockout Valves 1/4" to 1-1/2" port size

Mustang Series PRESSURE REDUCING CONTROL VALVE WITH PRESSURE SUSTAINING FEATURE. M115-2 (Globe) M (Angle) Schematic. Standard Components

Air Eliminators and Combination Air Eliminators Strainers

Model 4418F. Overview. Typical applications. Key features and benefits. Accreditations. Starting air/gas valve Vented fuel gas valve

API Flanged Safety Relief Valves Series 526 CATALOG

ball valves Flomite 71 Series 2-way Integral Panel Mount Ball Valves

Proportional Relief Valves

Principles of Direct-Operated Regulators

PRESSURE REDUCING CONTROL VALVE

relief valves 500 Series Adjustable Popoff & Inline Relief Valves 0.5 to 150 psig (10 bar)

BERMAD Waterworks. Quick Active Check Valve. 700 Series. Model 740Q. Features and Benefits. Major Additional Features

Fisher 1052 Size 20 Diaphragm Rotary Actuator with F and G Mounting Adaptation

APCO SLOW CLOSING AIR/VACUUM VALVES

Fisher FIELDVUE DVC6200 Digital Valve Controller / Magnet Assembly Dimensions

Ball Valves (HB Series) Catalog 4121-HB Revised, April 2005

Vogt Valves The Connection Bulletin for Forged Steel Flow Control Valves CB 15

Bristol Series 5453 Indicating Pneumatic Pressure Controllers/Transmitters

T U R B I N E G A S M E T E R

TECHNICAL DATA. Dry 122a. November 12, 2013

Integrated Custom Systems

Fisher 8580 Rotary Valve

Float and Thermostatic Traps Series H, C and X

Fisher C1 Pneumatic Controllers and Transmitters

TYPE E Main Valve Sizes 3 /8 through 12

08.08 Vic-Check Valves

BERMAD Waterworks. High Pressure, Surge Anticipating Control Valve. 800 Series. Model 835-M. Features and Benefits. Major Additional Features

Model F822 thru F834 Mulsifyre Directional Spray Nozzles, Open, High Velocity General Description

Incorrect use or failure of pressure regulators

Your safety and the safety of others are very important.

Kämmer Series Laboratory Valves

PRESSURE REGULATOR SERIES R 4100 R 2100 R 5100 VIRTUAL CATALOGUE FAIL TO OPEN REGULATOR BALANCED VALVE HIGH FLOW COEFFICIENT

Uncompromising Customer Service. Baumann TM Sanitary and Aseptic Process Valves

Stainless Steel Valves For the Sanitary Industries

Self-operated Pressure Regulators Universal Pressure Reducing Valve Type 41-23

Baumann 24000SB Barstock Control Valve

Pilot Operated Pressure Reducing Valve PRV 47 (Steel) PRV47I (St.Steel)

solenoid valves SV Series 2- and 3-way Solenoid Valves for Gas and Liquid

NDP-50 Specifications

2 WAY (2/2) AND 3 WAY (3/2) BRASS AND STAINLESS STEEL SOLENOID VALVES

BURSTCHECK LINE OF RUPTURE DISC BURST INDICATORS

VALVES FOR REFRIGERATING SYSTEMS

Non-Code Liquid Relief, ASME Section VIII, Air/Gas and Steam, National Board Certified, Safety and Relief Valves

Free Floating Lever Drain Traps For Loads to 50,000 lb/hr (22,679 kg/hr)...pressures to 1,000 psig (69 bar)

WATER PRESSURE REDUCING VALVES

Fisher GX Control Valves

SERIES ASM NEOPRENE/EPMD FLANGED SINGLE SPHERE CONNECTOR CONNECTORS. Pressures to 225 PSIG (15.51 barg) Temperatures to 230ºF (110ºC)

OPERATING and MAINTENANCE MANUAL SERIES 2700A CONTROL VALVE CONTENTS. INTRODUCTION...1 Scope...1 Description...1 Valve Identification...

% ^ ) 0.55 W Low Power Solenoid Valves Aluminum, Brass, or Stainless Steel Bodies 1/4" to 1" NPT. 2/2 3/2 4/2 5/2 5/3 SERIES Low Power

How To Make A Pressure Relief Valve

V47 Series Temperature Actuated Modulating Water Valves

3/2-way Solenoid Valve, direct-acting, NC or NO

Installation, Operation and Maintenance Manual for Pilot Operated Valves

Full Technical Catalog For Closed-loop Sampling System

Side-Trak 830/840. Process Gas Mass Flow Meters and Controllers.

PLUMBING RE-SUBMITTAL

Type 3353 Angle Seat Valve

PRESSURE REDUCER AND RELIEF VALVES WITH METALLIC BELLOW FOR WATER STEAM

Replacement parts. WM97+ gas-fired water boiler Boiler Manual. OBTAIN PARTS ONLY THROUGH WEIL-McLAIN THE BOILER CONTAINS CERAMIC FIBER MATERIALS

SIZING AND CAPACITIES OF GAS PIPING

DMP 331. Industrial Pressure Transmitter for Low Pressure. Stainless Steel Sensor

series Materials Body: 1/2, 3/4 and 1 : dezincification resistant alloy brass EN CW617N

Model 111 Mass Flow Instruments

TECHNICAL BULLETIN. Kämmer LinedFlow Corrosive Application Valves. Experience In Motion FCD KMENTB /12

G234X-55 Conventional Gas Boiler

S GATE KNIFE GATE VALVE WITH PNEUMATIC ACTUATOR

Fisher FIELDVUE DVC6200 SIS Digital Valve Controller for Safety Instrumented Systems (SIS)

Transcription:

October 14 89 Series Spring-Loaded Relief Valves W187_1 W1871 TYPE 89L 1 NPT TYPES 89H AND 89HH W187 NPT TYPE 89H W187_ TYPES 89U AND 89A Figure 1. Types 89H, 89L and 89U Relief Valves Introduction The 89 Series relief valve is a throttling relief valve used downstream of pressure regulators to protect the downstream system from overpressure. A smooth throttling action minimizes pressure surges in the system during emergency operation. These relief valves are available in 1/4, 3/4, 1 or NPT sizes with spring ranges (relief pressure settings) from 5 in. w.c. to 75 psig / 1 mbar to 5. bar. All sizes above 1/4 NPT feature a pitot tube booster (Figure 1) for achieving the highest possible relief capacity with a minimum buildup of system pressure. When the valve is opening, high gas velocity through the orifi ce creates an area of relatively low pressure near the end of the pitot tube. This pitot tube effect forms a partial vacuum above the diaphragm which helps to open the valve. The relief valve diaphragm functions as a valve disk to control fl ow in all types except the Types 89H and 89HH, which use O-ring seats. The Nitrile (NBR) or Neoprene (CR) seating surfaces provide tight shutoff. The 89 Series relief valves are ideal for low-pressure settings due to the increased sensitivity provided by the large diaphragm area. Features Throttling Type Relief Smooth, sensitive throttling action minimizes pressure surges. High Flow Rates As shown by the Figure 3 capacity curves, high fl ow rates can be achieved with minimum pressure buildup due to the boosting system which increases the relief valve opening. Small Size The 89 Series relief valves are small and compact, making them suitable for areas limited in space. Reliability Due to Simplicity A single internal assembly decreases the possibility of mechanical failure. D1154X1 www.fisherregulators.com

Specifications Available Configurations Type 89A: 1/4 NPT spring-loaded relief valve for relief pressure settings of 3 to psig /.1 to 1.5 bar, two spring ranges Type 89H: 1 or NPT spring-loaded relief valve for relief pressure settings of 1 to 5 psig /.7 to 3.4 bar four spring ranges, in the 1 NPT and of 7 in. w.c. to 1 psig / 17 mbar to.69 bar, four spring ranges, in the NPT Type 89HH: 1 NPT spring-loaded relief valve for relief pressure settings of 45 to 75 psig / 3.1 to 5. bar Type 89L: 3/4 or 1 NPT spring-loaded relief valve for relief pressure settings of 1 to 4 in. w.c. / 5 to 99 mbar, two spring ranges Type 89U: 1/4 NPT spring-loaded relief valve for relief pressure settings of 5 in. w.c. to 3 psig / 1 mbar to.1 bar, two spring ranges Inlet Connections Type 89L: 3/4 or 1 NPT Types 89A and 89U: 1/4 NPT Type 89H: 1 or NPT Type 89HH: 1 NPT Outlet (Vent) Connections Same size as inlet connection Maximum Allowable Relief (Inlet) Pressure (1) and Maximum Relief Set Pressure See Table 1 Capacity Data See Figure 3 Standard Construction Materials Valve Body and Spring Case Types 89A and 89U: Zinc Types 89H (1 NPT), 89HH and 89L: Aluminum Type 89H ( NPT): Cast iron body with Aluminum spring case Diaphragm Type 89A: Neoprene (CR) Types 89H and 89HH: Nitrile (NBR) or Fluorocarbon (FKM) Types 89L and 89U: Nitrile (NBR) Standard Construction Materials (continued) Orifice Types 89A and 89L: Aluminum Type 89H ( NPT Only): Brass or Stainless steel O-ring Seat (Types 89H and 89HH Only): Nitrile (NBR) or Fluorocarbon (FKM) () O-ring Seat Holder and Washer (1 NPT Types 89H and 89HH Only): Aluminum Seat Washer ( NPT Type 89H Only): Stainless steel Pitot Tube Types 89H, 89HH (1 NPT) and 89L: Aluminum Type 89H ( NPT): Brass or Stainless steel Gaskets Type 89L: Neoprene (CR) All Others: Composition Spring: Zinc-plated steel Diaphragm Plate Types 89A and 89U: Zinc All Others: Zinc-plated steel Closing Cap Type 89L: Plastic, Aluminum or Zinc Type 89H ( NPT): Zinc Temperature Capabilities (1) With Nitrile (NBR) and Neoprene (CR) Elastomer: - to 15 F / -9 to 66 C With Fluorocarbon (FKM): to 3 F / -7 to 149 C Available with Types 89H and 89HH only Approximate Weights Types 89A and 89U:.75 lbs /.3 kg Type 89H 1 NPT: 4 lbs / kg NPT: 15 lbs / 7 kg Type 89HH: 4 lbs / kg Type 89L: 15 lbs / 7 kg Options Polytetrafluoroethylene (PTFE) diaphragm protector (Types 89A and 89U only) Wire-seal on closing cap (1 NPT Type 89L only) 1. The pressure/temperature limits in this Bulletin and any applicable standard limitation should not be exceeded.. Bubble-tight shutoff cannot be attained at settings below 5 psig /.34 bar with Fluorocarbon (FKM) O-ring seat.

M147 M148 1 NPT TYPES 89H AND 89HH NPT TYPE 89H M149 M15 TYPE 89L TYPES 89U AND 89A INLET PRESSURE OUTLET PRESSURE ATMOSPHERIC PRESSURE Figure. Types 89H, 89L and 89U Operational Schematics Table 1. Maximum Allowable Relief (Inlet) Pressure AVAILABLE CONFIGURATION BODY SIZE, NPT Type 89A 1/4 Type 89H 1 SPRING PART NUMBER Z5637 1B687 1F86975 1D8937 1D75157 1D7455T1 1B536575 1B536675 1B536876 1B536975 COLOR CODE Pink Red Green Dark Blue Gray Dark Green Red Stripe SPRING RANGE (RELIEF PRESSURE SETTINGS) MAXIMUM ALLOWABLE RELIEF (INLET) PRESSURE (1) psig bar psig bar 3 to 13 11 to 1 to 4.5 4 to 15 1 to 15 to 5 7 to 18 in. w.c..5 to.5 1.75 to 7 4 to 1.1 to.9.76 to 1.5.7 to.31.8 to 1..69 to 1.4 1. to 3.5 17 to 45 mbar.3 to.16.1 to.48.8 to.69 45 3.1 1 6.9 5 1.7 Type 89HH 1 1D7455T1 Green 45 to 75 3.1 to 5. 1 6.9 Type 89L 3/4 or 1 13A7917X1 13A7916X1 Type 89U 1/4 V67 F587 1. This value indicates the relief pressure setting plus pressure build-up. Red Stripe 1 to 18 in. w.c. 1 to 4 in. w.c. 5 to 5 in. w.c. in. w.c. to 3 psig 5 to 45 mbar 3 to 99 mbar 1 to 6 mbar 5 to 7 mbar 7.48 1 psig.69 3

7 4.8 1 NPT TYPE 89H VENT SCREEN INSTALLED 6 4.1 5 psig / 3.4 bar 1D7455T1 5 3.5 4 psig /.8 bar 1D7455T1 4 3 1 A B C D 3 psig /.1 bar 1D7455T1 psig / 1.4 bar 1D75157 1 /.3 /.5 3 /.8 4 / 5 / 1.3 A-15 psig / 1. bar 1D75157 B-1 psig /.69 bar 1D75157 C-4 psig /.8 bar D-1 psig /.69 bar 1F86975 CAPACITIES IN THOUSANDS OF SCFH / Nm³/h OF.6 SPECIFIC GRAVITY NATURAL GAS AT 14.7 psia AT 6 F / 35 bar AT C 6 / 1.6 7 / 1.9 8 /.1.8.1 1.4.69 16 14 NPT TYPE 89H NO VENT RESTRICTION 1.97 1 1 psig /.69 bar 1B536975.83 1 8 6 7 psig /.48 bar 1B536876 5 psig /.35 bar 1B536876.69.55.41 4 4 / 8 /.1. psig /.14 bar 1B536675 1 /.3 16 /.4 /.5 4 /.6 1 psig /.7 bar 1B536675 8 /.8 3 /.9 36 / 1..5 psig /.3 bar 1B536575 4 / 44 / 1. 48 / 1.3 5 / 1.4 56 / 1.5 6 / 1.6 64 / 1.7.8.14 CAPACITIES IN THOUSANDS OF SCFH / Nm³/h OF.6 SPECIFIC GRAVITY NATURAL GAS AT 14.7 psia AT 6 F / 35 bar AT C NOTE: 1. LESS THAN A 5% CAPACITY LOSS CAN BE EXPECTED WITH THE VENT SCREEN INSTALLED ON THE NPT TYPE 89H AT MAXIMUM FLOW.. WHEN SELECTING ANY RELIEF VALVE FOR INSTALLATION DOWNSTREAM OF THE REGULATOR, THE CAPACITY OF THE RELIEF VALVE SHOULD BE COMPARED WITH THE WIDE-OPEN CAPACITY OF THE REGULATOR. 3. BUBBLE POINT RELIEF SETTING AND SPRING PART NUMBER ARE NOTED ON EACH CURVE. 4. TO CONVERT TO EQUIVALENT CAPACITIES OF OTHER GASES, MULTIPLY VALUES OBTAINED FROM CURVE BY THE FOLLOWING FACTORS: AIR =.78, PROPANE =.68, BUTANE =.548, NITROGEN =.789. Figure 3. Capacity Curves 4

1 6.9 9 6. 8 7 6 5 4 1 9 8 7 6 1 /.3 6 psig / 4.1 bar /.5 6 psig / 4.1 bar 3 /.8 75 psig / 5. bar 4 / 75 psig / 5. bar 5 / 1.3 5 psig / 3.4 bar 1 NPT TYPE 89HH VENT SCREEN INSTALLED SPRING 1D7455T1 6 / 1.6 7 / 1.9 5 psig / 3.4 bar 5.5 4.8 4.1 3.5.7 8 /.1 6.9 6. 5.5 4.8 4.1 5 4 1 /.3 /.5 3 /.8 4 / 5 / 1.3 6 / 1.6 7 / 1.9 8 /.1 1 NPT TYPE 89HH NO VENT RESTRICTION SPRING 1D7455T1 9 /.4 1 /.7 11 / 3. 3.5.8 1 / 3. CAPACITIES IN THOUSANDS OF SCFH / Nm³/h OF.6 SPECIFIC GRAVITY NATURAL GAS AT 14.7 psia AT 6 F / 35 bar AT C 5.35 TYPE 89U 4.8 3 3 psig /.1 bar F587 psig /.14 bar F587 IN. W.C. / 5 mbar F587.1.14 1 4 IN. W.C. / 6 mbar 7 IN. W.C. / 17 mbar V67.7 / 1 /.7 / 5.4 3 / 8. 4 / 1.7 5 / 13.4 6 / 16.1 7 / 18.8 CAPACITIES IN.6 SPECIFIC GRAVITY GAS CUBIC FEET PER HOUR / Nm 3 /h 14.7 psia AT 6 F / 35 bar AT C NOTE: 1. WHEN SELECTING ANY RELIEF VALVE FOR INSTALLATION DOWNSTREAM OF THE REGULATOR, THE CAPACITY OF THE RELIEF VALVE SHOULD BE COMPARED WITH THE WIDE-OPEN CAPACITY OF THE REGULATOR.. BUBBLE POINT RELIEF SETTING AND SPRING PART NUMBER ARE NOTED ON EACH CURVE. 3. TO CONVERT TO EQUIVALENT CAPACITIES OF OTHER GASES, MULTIPLY VALUES OBTAINED FROM CURVE BY THE FOLLOWING FACTORS: AIR =.78, PROPANE =.68, BUTANE =.548, NITROGEN =.789. Figure 3. Capacity Curves (continued) 5

4.8 3/4 and 1 NPT TYPE 89L VENT SCREEN INSTALLED 3 1 1 psig /.7 bar 3/4 npt SIZE 1 npt SIZE.1.14.7.5 psig /.3 bar 1 / 6.8 / 53.6 3 / 8.4 4 / 17 5 / 134 6 / 161 7 / 188 8 / 14 9 / 41 1, / 68 CAPACITIES IN SCFH / nm³/h OF.6 SPECIFIC GRAVITY NATURAL GAS AT 14.7 PSIA AT 6 F / 35 bar AT C 3.7 Type 89A 5 psig / 1.5 bar 1B687 1.7 18 psig / 1.4 bar 1B687 15 13 psig /.9 bar Z5637 15 psig / 1.3 bar 1B687 1.4 1.3 11 psig /.76 bar 1B687 1 psig /.69 bar Z56317 1 5 psig /.35 bar Z5637.7 5 3 psig /.1 bar Z5637.35 / 5.36 4 / 1.7 6 / 16.1 8 / 1.4 1 / 6.8 CAPACITIES IN SCFH / nm³/h OF.6 SPECIFIC GRAVITY NATURAL GAS AT 14.7 psia AT 6 F / 35 bar AT C NOTE: 1. WHEN SELECTING ANY RELIEF VALVE FOR INSTALLATION DOWNSTREAM OF THE REGULATOR, THE CAPACITY OF THE RELIEF VALVE SHOULD BE COMPARED WITH THE WIDE-OPEN CAPACITY OF THE REGULATOR.. BUBBLE POINT RELIEF SETTING is NOTED ON EACH CURVE. 3. TO CONVERT TO EQUIVALENT CAPACITIES OF OTHER GASES, MULTIPLY VALUES OBTAINED FROM CURVE BY THE FOLLOWING FACTORS: AIR =.78, PROPANE =.68, BUTANE =.548, NITROGEN =.789. Figure 3. Capacity Curves (continued) 6

PROTECTIVE VENT PIPE WITH RAIN CAP NPT TYPE 89H RELIEF VALVE LARGE SERVICE REGULATOR AJ4698_C A1947_1 Figure 4. Typical Installation of a 89 Series Relief Valve Installation The 89 Series relief valves may be installed in any position. However, the outlet connection must be protected against the entrance of rain, snow, insects or any other foreign material that may plug the outlet or affect the opening and closing of the valve (see Figure 4). If it is necessary to pipe away the outlet, remove the outlet screen (if one is present). Flow through the valve must be as indicated by the flow direction arrow on the body (inlet connection is marked on some sizes). The spring case vent on the NPT Type 89H is tapped and plugged. This vent opening must remain plugged to allow the pitot tube booster to function. Overpressure Overpressure conditions in a regulating system may cause personal injury or equipment damage due to bursting of pressure-containing parts or explosion of accumulated gas. Check the system for damage if any of the maximum allowable relief (inlet) pressure ratings in Table 1 are exceeded. Ordering Information When ordering, specify: 1. Type number and size. Relief pressure range and setting desired 3. Type of gas (natural gas, air, etc.); list any factors such as impurities in the gas that may affect compatibility of the gas with valve trim parts 4. Temperature and specific gravity of the gas 5. Maximum relief (inlet) pressure and flow rate desired 6. Line size and end connection size of adjacent piping 7. For Types 89H and 89HH, specify material of diaphragm and O-ring seat; for NPT Type 89H, specify material of orifice and pitot tube 8. Options desired, if any. 7

3.6D / 78 4.88 / 14 1/4 NPT.38 / 9.7.5 / 57 5.38 / 137 1.5 / 3.38 / 9.7 TYPES 89A AND 89U 1/4 NPT 4.1 / 15 1.94 / 49 TYPE 89L 3/4 AND 1 NPT 7.1 / 181 8.69 / 1 8.94 / 7 A1393_ Figure 5. Dimensions 1.88 / 48 TYPES 89H AND 89HH 1 NPT 1.78 / 45. 3.56 / 9 TYPE 89H NPT.1 / 54 IN. / mm Industrial Regulators Emerson Process Management Regulator Technologies, Inc. USA - Headquarters McKinney, Texas 757 USA Tel: +1 8 558 5853 Outside U.S. +1 97 548 3574 Asia-Pacifi c Shanghai 16, China Tel: +86 1 89 9 Europe Bologna 413, Italy Tel: +39 51 419 611 Middle East and Africa Dubai, United Arab Emirates Tel: +971 4811 81 Natural Gas Technologies Emerson Process Management Regulator Technologies, Inc. USA - Headquarters McKinney, Texas 757 USA Tel: +1 8 558 5853 Outside U.S. +1 97 548 3574 Asia-Pacifi c Singapore 18461, Singapore Tel: +65 677 8337 Europe Bologna 413, Italy Tel: +39 51 419 611 Chartres 88, France Tel: +33 37 33 47 Middle East and Africa Dubai, United Arab Emirates Tel: +971 4811 81 TESCOM Emerson Process Management Tescom Corporation USA - Headquarters Elk River, Minnesota 5533-445, USA Tels: +1 763 41 338 +1 8 447 15 Europe Selmsdorf 393, Germany Tel: +49 3883 31 87 Asia-Pacifi c Shanghai 16, China Tel: +86 1 89 9499 For further information visit www.emersonprocess.com/regulators The Emerson logo is a trademark and service mark of Emerson Electric Co. All other marks are the property of their prospective owners. Fisher is a mark owned by Fisher Controls International LLC, a business of Emerson Process Management. The contents of this publication are presented for informational purposes only, and while every effort has been made to ensure their accuracy, they are not to be construed as warranties or guarantees, express or implied, regarding the products or services described herein or their use or applicability. We reserve the right to modify or improve the designs or specifi cations of such products at any time without notice. Emerson Process Management Regulator Technologies, Inc. does not assume responsibility for the selection, use or maintenance of any product. Responsibility for proper selection, use and maintenance of any Emerson Process Management Regulator Technologies, Inc. product remains solely with the purchaser. Emerson Process Management Regulator Technologies, Inc., 197, 14; All Rights Reserved