IDENTIFYING NATURAL GEMS FROM SYNTHETIC AND TREATED COUNTERPARTS USING THE AGILENT CARY 660

Similar documents
Introduction to Fourier Transform Infrared Spectrometry

Name: Class: Date: Multiple Choice Identify the letter of the choice that best completes the statement or answers the question.

The Fundamentals of Infrared Spectroscopy. Joe Van Gompel, PhD

DETECTION OF COATINGS ON PAPER USING INFRA RED SPECTROSCOPY

MB3600 Versatile FT-NIR analyzer designed for your industry The most reliable FT-NIR specifically designed for QA/QC

FTIR Instrumentation

Components for Infrared Spectroscopy. Dispersive IR Spectroscopy

QUANTITATIVE DETERMINATION OF COMMON TYPES OF ASBESTOS BY DIFFUSE REFLECTANCE FTIR

Infrared Spectroscopy 紅 外 線 光 譜 儀

Advanced Solutions for Gas Monitoring

Back to Basics Fundamentals of Polymer Analysis

Experiment #5: Qualitative Absorption Spectroscopy

QUANTITATIVE INFRARED SPECTROSCOPY. Willard et. al. Instrumental Methods of Analysis, 7th edition, Wadsworth Publishing Co., Belmont, CA 1988, Ch 11.

FTIR and DSC of polymer films used for packaging: LLDPE, PP and PVDC

GIANT FREQUENCY SHIFT OF INTRAMOLECULAR VIBRATION BAND IN THE RAMAN SPECTRA OF WATER ON THE SILVER SURFACE. M.E. Kompan

IUCLID 5 COMPOSITION AND ANALYSIS GUIDANCE DOCUMENT: IRON ORES, AGGLOMERATES [EINECS NUMBER , CAS NUMBER ] IRON ORE PELLETS

Detection of Exposure Damage in Composite Materials Using Fourier Transform Infrared Technology

TABLE OF CONTENTS CHAPTER TITLE PAGE DECLARATION ACKNOWLEDGEMENT ABSTRACT LIST OF TABLES LIST OF FIGURES LIST OF SYMBOLS LIST OF APPENDICES

Absorption by atmospheric gases in the IR, visible and UV spectral regions.

NMR and other Instrumental Techniques in Chemistry and the proposed National Curriculum.

INFRARED SPECTROSCOPY (IR)

h e l p s y o u C O N T R O L

Realization of a UV fisheye hyperspectral camera

ANALYSIS OF ASPIRIN INFRARED (IR) SPECTROSCOPY AND MELTING POINT DETERMINATION

Preface Light Microscopy X-ray Diffraction Methods

Nano-Spectroscopy. Solutions AFM-Raman, TERS, NSOM Chemical imaging at the nanoscale

Features of the formation of hydrogen bonds in solutions of polysaccharides during their use in various industrial processes. V.Mank a, O.

UV/VIS/IR SPECTROSCOPY ANALYSIS OF NANOPARTICLES

Beryllium Treated Blue Sapphires. Continuing market observations and update including the emergence of larger size stones

CHEM 51LB: EXPERIMENT 5 SPECTROSCOPIC METHODS: INFRARED AND NUCLEAR MAGNETIC RESONANCE SPECTROSCOPY

Organic Spectroscopy

Coating Thickness and Composition Analysis by Micro-EDXRF

UV-VIS-NIR. Varian Cary 4000, 5000 and 6000i Spectrophotometers

Raman spectroscopy Lecture

Measurement & Analytics Measurement made easy

MB3600-HP12 / Measurement & Analytics. Laboratory FT-NIR Heavy Oils Analyzer Crude oil, fuel oil, heavy oil upgrader unit feeds

DETERMINACIÓN DE ESTRUCTURAS ORGÁNICAS (ORGANIC SPECTROSCOPY) IR SPECTROSCOPY

foster + freeman ECCO APPLICATIONS Discriminating Printer Toners using LIBS

DNA NANOWIRES USING NANOPARTICLES ECG653 Project Report submitted by GOPI

Raman Spectroscopy. 1. Introduction. 2. More on Raman Scattering. " scattered. " incident

Homeland Security, Medical, Pharmaceutical and Non-destructive Testing Applications of Terahertz Radiation

Raising the Bar in FT-IR: Getting the Most Out of On-site Oil Condition Monitoring

Developments in Ore Sorting Technologies

IR Applied to Isomer Analysis

13C NMR Spectroscopy

Bridging the analytical gap

Asian Journal of Food and Agro-Industry ISSN Available online at

How To Use A Detector 2

MB3000-PH FT-IR spectrometer for the pharmaceutical industry Designed for QA/QC, formulation, research and development laboratory applications

Electromagnetic Radiation (EMR) and Remote Sensing

Fiber Optic Sampling by UV/Vis and UV/Vis/NIR Spectroscopy

Blackbody Radiation References INTRODUCTION

The CVD diamond booklet

Silicon, the test mass substrate of tomorrow? Jerome Degallaix The Next Detectors for Gravitational Wave Astronomy Beijing

Pesticide Analysis by Mass Spectrometry

Analytical Testing Services Commercial Price List ManTech International Corporation January 2016

Spectroscopy. Biogeochemical Methods OCN 633. Rebecca Briggs

- thus, the total number of atoms per second that absorb a photon is

Uses of Derivative Spectroscopy

Potassium Aluminium Silicate (Mica) Chemical and Technical Assessment (CTA) Prepared by Daniel E. Folmer, Ph.D., and reviewed by Madduri V. Rao, Ph.D.

The forensic analysis of soil organic by FTIR

Signal to Noise Instrumental Excel Assignment

Unit title: Chemical Laboratory Techniques

Energy Transport. Focus on heat transfer. Heat Transfer Mechanisms: Conduction Radiation Convection (mass movement of fluids)

Principle of Thermal Imaging

Objectives: Vocabulary: Materials: Students will: Safety: Element Mineral Streak. Absolute Hardness

Infrared Spectroscopy: Theory

Symmetric Stretch: allows molecule to move through space

Al 2 O 3, Its Different Molecular Structures, Atomic Layer Deposition, and Dielectrics

** Rocks are aggregates of one or more minerals ** 3. Hardness: A measure of resistance to scratching. On the Mohs Scale, it ranges from 1 to 10.

Physical and Chemical Property Changes of Coffee Beans during Roasting

Photoinduced volume change in chalcogenide glasses

Anharmonicity and Weak Mode Assignment in La 2 x Sr x CuO 4 with Oxygen Isotopic Substitution

THE TYPE CLASSIFICATION SYSTEM OF DIAMONDS AND ITS IMPORTANCE IN GEMOLOGY

Gas emission measurements with a FTIR gas analyzer - verification of the analysis method Kari Pieniniemi 1 * and Ulla Lassi 1, 2

Determining the Structure of an Organic Compound

International Year of Light 2015 Tech-Talks BREGENZ: Mehmet Arik Well-Being in Office Applications Light Measurement & Quality Parameters

Cary 100 Bio UV-Vis Operating Instructions 09/25/2012 S.V.

MPA. Innovation with Integrity. Multi Purpose Analyzer FT-NIR

Prussian blue nanoparticles for laser-induced photothermal therapy of tumors

Nanoscience Course Descriptions

2. Molecular stucture/basic

5.33 Lecture Notes: Introduction to Spectroscopy

The excitation in Raman spectroscopy is usually. Practical Group Theory and Raman Spectroscopy, Part II: Application of Polarization

Department of Aerospace Engineering Indian Institute of Science Bangalore

Organic Chemistry Tenth Edition

UV-Vis spectrophotometers

Nuclear Magnetic Resonance (NMR) Wade Textbook

Ultraviolet Spectroscopy

Matter, Materials, Crystal Structure and Bonding. Chris J. Pickard

Applications of Infrared Multiple Angle Incidence Resolution Spectrometry

EXPERIMENT 11 UV/VIS Spectroscopy and Spectrophotometry: Spectrophotometric Analysis of Potassium Permanganate Solutions.

Spectrophotometry and the Beer-Lambert Law: An Important Analytical Technique in Chemistry

The Periodic Table: Periodic trends

Austin Peay State University Department of Chemistry Chem The Use of the Spectrophotometer and Beer's Law

The mechanical properties of metal affected by heat treatment are:

Ion Beam Sputtering: Practical Applications to Electron Microscopy

XFA 600 Thermal Diffusivity Thermal Conductivity

In this column installment, we present results of tablet. Raman Microscopy for Detecting Counterfeit Drugs A Study of the Tablets Versus the Packaging

Transcription:

MATERIALS AALYSIS IDETIFYIG ATURAL GEMS FROM SYTHETI AD TREATED OUTERPARTS USIG THE AGILET ARY 660 Solutions for Your Analytical Business Markets and Applications Programs Solution ote Materials Author(s) Ashish Kumar, Agilent Technologies, Inc. Manesar, India Marion Boerger, Agilent Technologies, Inc. Germany Introduction Gemstones are an important commodity in today s marketplace. Due to the high variety of capabilities, the production of synthetic gemstones is a growing market. A synthetic gemstone shares a natural stone s physical, chemical and often optical qualities, but it is created in a laboratory. owadays, synthetic versions of nearly all popular gemstones are available. In many cases synthetic gemstones are difficult to identify. Jewellery that includes quality synthetic gems can be just as beautiful as jewellery made with natural stones. During the last decade, 2000 2010, some spin-offs from mainstream materials science have entered the gemstone industry and have brought many new challenges in the field of testing methodologies. This has a special reference to high pressure high temperature (HPHT) / chemical vapour deposition (VD) synthesis of diamonds, the development of diamond simulants like moissanite, synthetic cubic zirconia, production of black diamonds, beryllium treatment of sapphires for colour enhancement, lead glass filling in rubies etc. In view of these developments, detection of genuine diamonds from a host of look-alikes has become an important issue in the diamond trade. It is important to note that identification of synthetic diamonds is possible only with the help of spectroscopic analyses. onventional gemmological instruments and methods are not enough to distinguish synthetic diamonds from their natural counterparts. Fourier Transform Infrared Spectroscopy (FTIR) is a nondestructive method used to analyse gemstones. This technique can produce important information about all kinds of gemstones within a few minutes. FTIR Spectroscopy can be used for a broad field of applications in the gemstones industry, several examples of which are described in this solution note.

Experimental Setup Spectrometer All spectra were measured using the Agilent ary 660 FTIR spectrometer (Figure 1). The ary 660 FTIR is a versatile, high performing spectrometer designed to meet routine spectroscopy and research application needs. It is based on a 38 mm dynamically aligned, 60 mechanical bearing Michelson interferometer and is capable of covering the widest spectral range from 53000 cm -1 to 20 cm -1. Due to the large sample compartment, it is compatible with a wide range of accessories that provide extra capabilities. The ary 660 FTIR is controlled by Resolution Pro Software, including all the important features for spectral analysis. This spectrometer offers superb performance levels, spectral resolutions and signalto-noise measurements. It is ideal for a wide range of applications and industries from petro/chemicals to materials/polymers and life sciences. For these measurements, the ary 660 FTIR was equipped with Agilent s patent DURAGLOW TM Mid-IR source, Potassium Bromide (KBr) Beamsplitter and a linearised broad band Mercury admium Telluride (MT) detector. This standard configuration provides a measurement range from 7500 cm -1 to 450 cm -1. Results and Discussion Typification of nitrogen substitution in diamonds Figure 2 shows a comparison of the FTIR spectra of synthetic diamond and natural diamond in the wavenumber range 1650 cm -1 to 400 cm -1. In this spectral range, there are absorption bands correlating to nitrogen induced one phonon absorbance. 98 % of all natural diamonds have around 0.1 % nitrogen. These are classified as Type Ia diamond. Within diamond Type Ia, two agglomerate exist - IaA and IaB, as shown in Table 1. Synthetic diamonds exist mostly as Type Ib, containing up to 0.05 % nitrogen. The absorption band at 1282 cm -1 is characteristic for diamond Type IaA, the absorption band at 1175 cm -1 for diamond Type IaB and the absorption band at 1130 cm -1 for diamond Type Ib [1,2,3,4]. 1282 1175 1130 Synthetic Diamond atural Diamond 1600 1400 1200 1000 800 600 Figure 2: omparison of FTIR spectra of synthetic Diamond and natural Diamond in the wavenumber range 1650 cm -1 to 400 cm -1. Type IaA diamond Type IaB diamond Type Ib diamond empty Figure1: Agilent s ary 660 FTIR spectrometer. Spectra acquisition All spectra were collected in transmission mode, with a spectral resolution of 4 cm -1. For background, as well as for sample spectra, 128 scans per measurement were taken. The sizes of the gemstones were between 7 mm and 20 mm. All stones were placed into the sample compartment, without further manipulation, using a magnetic holder. 1282 cm -1 1175 cm -1 1130 cm -1 Table 1: lassification of diamond Types IaA, IaB and Ib. The spectrum of synthetic diamond is dominated by the absorption at 1130 cm -1, whereas the spectrum of natural diamond is dominated by the absorbance at 1282 cm -1 and 1175 cm -1. This result is in accordance with literature [1,2,3,4,5]. These measurements on diamond, performed without any sample preparation within a few minutes, can easily distinguish synthetic diamond, Type Ib, from natural diamond, Type Ia. 2

Inclusions in emerald and the analysis of natural and synthetic emerald The chemical composition of emerald is defined as Be 3 Al 2 (SiO 3 ) 6. It can have numerous gaps on the surface and different inclusions. If an emerald has no visible inclusions, it is classified as a flawless gemstone. Since emerald can have many gaps, it shows an uneven dye distribution. To improve the appearance, it is an accepted trade practice all over the world that emeralds are oiled or treated in other ways. They are classified as having either none, minor, moderate or highly enhanced modification. X-ray fluorescence is a very expensive technique to analyse emerald. Since inclusions provide an opportunity to distinguish between natural and synthetic emeralds, FTIR spectroscopy is a low cost and very fast method to proof these gemstones. Identification of resin filled emeralds As previously written, it is a general trade practice to oil emeralds, with a view to solidify their strength and improve appearance. The use of coloured oil and resins have to be declared whilst trading in the gem market. With the help of FTIR, it is possible to differentiate between peaks for oil and resin. Figure 4 shows the FTIR spectra of natural and treated emerald. The wavenumber range between 3200 cm -1 and 2800 cm -1 clearly shows absorption bands that originate from resin. Since oil and resin show absorption in the MID-IR spectrum, FTIR can be used to determine whether emeralds have been treated. It was found that the FTIR spectra of natural and hydrothermal synthetic emeralds show different absorption in the spectral range of 2600 cm- -1 to 3000 cm -1. Absorption bands at 2830 cm -1 and 2745 cm -1 have never been detected in natural emeralds [6]. Figure 3 shows a comparison of the FTIR spectra of a hydrothermal synthetic emerald and a natural emerald in the wavenumber range 3400 cm -1 to 2400 cm -1. The FTIR spectrum of hydrothermal synthetic emerald shows strong absorption bands at 2745 cm -1, 2830 cm -1 and 2870 cm -1. 3164 3059 resin 3035 resin 2963 2929 2870 atural Emerald Treated Emerald Synthetic Emerald atural Emerald 2870 2830 cm -1 2745 cm -1 3200 3000 2800 2600 2400 Figure 4: FTIR spectra of natural and treated emeralds in the wavenumber range 3200 cm -1 to 2400 cm -1. 3200 3000 2800 2600 2400 Figure 3: omparison of FTIR spectra of synthetic emerald and natural emerald in the wavenumber range 3400 cm -1 to 2400 cm -1. This demonstrates that by using FTIR spectra, it is possible within a few minutes, to distinguish between natural and hydrothermal synthetic emeralds. 3

Ruby Ruby is a variety of the mineral species corundum and has been a popular gemstone for centuries. With its characteristic red colour and high hardness, its value is unrivalled by any other gemstones. The red colour in stone is due to the presence of trace elements such as chromium (r), iron (Fe) or titanium (Ti). Advances in crystal growth technology have made the creation of synthetic rubies a reality. As a result there exist numerous synthetic and simulated rubies in the gem market which are not easily identified through the use of basic gemmological methods. Identification of Heat Treated corundum orundum has a crystal system of Al 2 O 3. It is transparent but can have different colours, depending of impurities. The red modification is called ruby and arises from integrated chromium. orundum can be heated to improve milkiness and asterism or remove colour and even to alter imperfections [7]. Figure 5 shows the FTIR spectra of heat treated ruby and natural ruby in the spectral range of 3500 cm -1 to 2400 cm -1. The spectrum of heated ruby clearly shows an absorption band at 3309 cm -1. This peak was also found in 27 Marosely corundum specimens [8]. Thermal treatment can result in the transformation of diaspore [AlO(OH)] to aluminium oxide [Al 2 O 3 ]. The absorption at 3309 cm -1 may be caused from structurally bound OH. The development of broad absorption from 3000 cm -1 extended to 3600 cm -1 would be due to the random distribution of unbound hydroxyl groups. FTIR spectroscopy has been found to be invaluable in the detection of heat treatment of rubies and sapphires. Identification of filling of rubies with foreign substances Filling is one type of ruby treatment that represents the low or high temperature heat treatment process with a number of additives or fluxes. After solidification these additives or fluxes form glassy substances in fissures and cavities and also on the surface of the treated stone. FTIR spectra for all lead glass filled rubies show three absorption bands at 2250 cm -1, 2600 cm -1 and 3500 cm- -1. According to Scholze [9], the broad band at 3500 cm -1 can be attributed to the absorption of H 2 O molecules. The peaks at 2250 cm- -1 and 2600 cm -1 are related to Si-OH vibrations, as noticed by Efimov et al. [10,11]. In the case of glass filled rubies, a broad absorption centered around 2600 cm -1 is a diagnostic signal for identifying fracture filling with glassy substances such as lead glass, bismuth, silica and borax. evertheless, FTIR spectra cannot differentiate as to what type of filler is used to enhance the colour. Figure 6 shows the hump at 2600 cm -1 which is due to this fracture filling, demonstrating that these bands in the FTIR spectra could become a good indication of glass filling in rubies. atural Ruby Heated Ruby 3309 atural Ruby Treated Ruby 3400 3200 3000 2800 2600 2400 Figure 5: FTIR spectra of natural and treated ruby in the wavenumber range 3500 cm -1 to 2400 cm -1. 3400 3200 3000 2800 2600 Figure 6: FTIR spectra of natural and treated ruby in the wavenumber range 3500 cm -1 to 2400 cm -1. 4

onclusion FTIR spectroscopy is a powerful technique used to analyse all sorts of gemstones. This application note shows that within a few minutes, it is possible to determine whether a gemstone is natural or has been treated. Agilent s ary 660 FTIR is a versatile instrument as a consequence of its high energy throughput, sensitivity and spectral range. The sample compartment is large and allows for the use of specialist accessories. The gemstones measured for this application note were mounted on a magnetic transmission holder and measured at room temperature. The analysis of synthetic and natural amethyst for example, is complex. The FTIR spectrum of amethyst is a function of growing conditions like temperature, pressure and growth rate. This is an example where a special sample holder, which can be heated or put under pressure, may be useful. Agilent s ary 660 offers this possibility. References J.R. Hardy and S.D. Smith, Two-phonon infra-red lattice absorption in diamond; Philosophical Magazine, 6, 1163 1172, 1961. R. Mecke and F. Langenbucher, Infrared spectra of selected chemical compounds; Heyden & Son Limited, London, UK, 1965. G. Davies, The optical properties of diamond, hemistry and Physics of arbon, 13, 1 143, 1977. D.T. Morelli, T.A. Perry and J.W. Farmer, Phonon scattering in lightly neutron-irradiated diamond, Phys. Rev. B, 47, 131 139, 1993. T. Evans, Aggregation of nitrogen in diamond. In: J. Field, The properties of natural and synthetic diamond, Academic Press, London, 259-290.. M. Stockton, The separation of natural from synthetic emeralds by infrared, Gems & Gemology, 23 (2), 96-99, Summer 1987. K. assau, Heat treating Rubin and sapphire: Technical aspects, Gems and Gemology, 17 (3), 121-131; Fall 1981. L.E. artier, Ruby and sapphire from Marosely, Madagascar, The Journal of Gemmology, 31 (5 8), 171-179, 2009. H. Scholze, Glass: nature, structure and properties, Springer, ew York, 1991. A.M. Efimov, V.G. Pogareva and A.V. Shashkin, Water-related bands in the IR absorption spectra of silicate glasses, Journal of on- rystalline Solids, 332, 93-114, 2003. Scholze (2003) for glasses. [Roman Serov; FTIR spectroscopy of glass filled rubies; Gemological enter, Moscow State University] 5

Agilent Products are for Research Use Only. ot for use in diagnostic procedures. Information, descriptions and specifications in this publication are subject to change without notice. Solutions for your Analytical Business Markets & Applications Programs www.solutions-to-win.com Agilent Technologies, Inc. 2014 Published in USA, February 14, 2014 5991-3976EE