Pressure switches for gas and air Pressure sensors



Similar documents
Pressure Switch for gas and air

Electric Rotary Actuator - On/Off or programmable control actuator

97300 NAMUR series, 3/2 & 5/2 Indirect solenoid actuated spool valve

Valve Proving System VPS 504 Series S06 (120 VAC) Series S05 (24 VDC)

Assisted lift operated 2/2-way solenoid valves Type EV250B

How To Control A Power Supply With A Mini Transmitter And Switch (Power Supply)

Instruction Manual Differential Pressure Transmitter

3/2-way Solenoid Valve, direct-acting, NC or NO

Solenoid Valve Island Type 3965

VP23, 3-way proportional pressure control valves Seat valve with μp-driven pressure control

Electronic pressure switch with display Model PSD-30, standard version Model PSD-31, with flush diaphragm

2/ These vacuum switches are used in measuring ranges between -1 and 0 bar.

Heating, air-conditioning, cooling

Proportional pressure regulators VPPE

Electronic Pressure Switch EDS 300

Pressure transmitter For general industrial applications Model A-10

Single sub-base valve

Solenoid Valve Type 3962

820 NOVA mv THERMOPILE POWER SUPPLY THERMOELECTRIC SAFETY DEVICE SERVO-CONTROLLED PRESSURE REGULATOR SHUT-OFF SOLENOID VALVE.

System 6000 Electropneumatic Converter for Direct Current Signals Type 6116 i/p Converter

DMP 331. Industrial Pressure Transmitter for Low Pressure. Stainless Steel Sensor

Series P215PR/RM Direct- and Remote-Mount Pressure-Actuated Condenser Fan Speed Controllers for Single-Phase Motors

Self-operated Pressure Regulators Universal Pressure Reducing Valve Type 41-23

Plastic tube flowmeters Series PT/PS

Control- and feedback head for integrated mounting on Robolux valves Type 2036

Differential Pressure Sensors for air and non-corrosive gases, with calibration certificate

Valve series MN-06 acc. to NAMUR, 3/2-way G1/4 750 Nl/min (0.762 Cv)

Cable Plug acc. to DIN EN , Form A

4 Posiflow Proportional Solenoid Valves

Fluxi 2000/TZ Turbine Gas Meter

PPS-PPQ-BT-PIAS RESIN INSULATORS FOR OIL INSULATED ELECTRICAL MACHINES

Oil - kerosene burners

On-off valves MS-EM/EE, MS series, NPT

DEK-REL- 24/1/SEN. Extract from the online catalog. Order No.:

Tilt switches N3 / N4... MEMS technology, one or two axis. Use. Options. + long lifetime and highly reliability due to mechanism-free MEMS technology

Conductive Level Switch FK 2 Technical Data:

Solenoid valves 2/2-way direct-operated Type EV210A

Series 7500 Torque Sensor

RM/55401/M, Roundline cylinder Magnetic piston, double acting

3/2-, 5/2- and 5/3-way Solenoid Valves for process pneumatics

VDL 53 - Vacuum drying oven for flammable solvents

The SF2 series are designed for reservoir side-wall mounting applications, suitable for flow rates to 850 l/min and filtration from 25 to 250 micron.

PIEZOMETER AIRFLOW MEASURING RING

OEM Relative and differential pressure switch type 605

Vacuum drying oven for non-flammable solvents

1 Safety instructions. 2 Device components. 3 Function. Leader in Led solutions. Compact presence detector. Operating instructions

Relative and absolute pressure switch type 529

Throughbeam photoelectric sensors. Dimensioned drawing. Electrical connection

Digital inductive conductivity transmitter

SITRANS F flowmeters SITRANS F M

FIXED DISPLACEMENT HYDRAULIC VANE PUMPS BQ SERIES

Compact pressure switch Flameproof enclosure Ex d Model PCA

FIXED DISPLACEMENT HYDRAULIC VANE PUMPS BQ SERIES

ARI-DP30 / DP32 / DP33 / DP34 / DP34T / DP34Tri / DP35 Pneumatic actuator ARI-DP Pneumatic actuator ARI-DP

4. Combi valves. 7. Fire hydrants. 8. Check valves. 9. Air valves

Digital pressure gauge for industrial applications Model DG-10-S, Standard version Model DG-10-E, Enhanced version

TECHNICAL DATASHEET Incremental Encoder RI 58-D / RI 58TD

FIXED DISPLACEMENT HYDRAULIC VANE PUMPS BQ SERIES

LENORD. +BAUER... automates motion. PowerDRIVE-Positioning GEL 6109 Compact positioning drive for installation situations with limited space

Dual Pressure Controls for Refrigeration, Air-conditioning and Heatpump Applications

Incubator with mechanical convection

B MOTORSPORT COMPONENTS B13. Max Circuit Measurement Characteristic Current Thread Part Number Range Curve [A] Size Connector Figure Comment

14 PHOENIX CONTACT Courtesy of Power/mation Energy Lane, Saint Paul, MN

EMO T. Thermal actuator for heating, ventilation and air conditioning systems

Electro-pneumatic control valves

Solenoid valves Type EVU

Pressure monitoring equipment for oil-sf 6. bushings, type GOEK

N20xxA, N34xxA NON-SPRING RETURN DIRECT-COUPLED DAMPER ACTUATORS FOR FLOATING AND 2-POSITION CONTROL

NIVOCONT CONDUCTIVE LEVEL SWITCHES LEVEL SWITCHES

3/2- and 2/2-way cartridge valve type BVE

How To Use A Flowmeter

Electronic Pressure Monitoring New Products

SQUARE D INDUSTRIAL CONTROL PRODUCTS

Fluid Level Gauge Fluid Level Sensor Temperature Switch FSA / FSK / TS

Instruction Manual MSC710 MSC710-U MSC710-I

Turbine Flow Sensor Series VTR

Type 3353 Angle Seat Valve

Product data sheet. JUMO MIDAS Pressure Transmitter. Sales No. Order code JUMO AS /

MILLENIUM INSTALLATION MANUAL NTR 735 A. Simple Automation Control Module (MAS)

Butterfly valves BVG, BVGF, BVA, BVAF, BVH, BVHS, BVHM

3/2-way Mini Solenoid Valve

Housing diameter Shaft diameter 1. Flange (Mounting of housing) Protection class shaft input (EN 60529) Protection class housing (EN 60529)

Fluid. Flu. Fluid Fluid. uid Power d Power P. Fluid Power P. Fluid Power. Fluid Power Power. d Power. Directional Cetop Valves DCV 03.

Shutter Actuator Standard, 4-fold, 230 VAC, MDRC RA/S , GH Q R0111. ABB i-bus EIB

New XUY roller sensors

Electrically operated valves Series M-05, 3/2-, 5/2- and 5/3-way G1/8 650 and 750 Nl/min (0.661 and Cv)

OUT. The SF2 series suction filter are designed for reservoir side-wall applications. This completely new design of filter allows the filter

Parts Manual. TWIN 2 & 3 Parts & Accessories F210846R01. Your efficiency is our Challenge!

Ball valve C 16 valve ball completely moulded in place, extremely low clearance volume, high k v value

Industrial circular connectors

TECHNICAL DATASHEET Incremental Encoder RI 58-H

compressed air conditioning accessories. one stop shop process reliable efficient economical high degree of reusability

Magnetic field sensor for pneumatic cylinders BIM-INT-Y1X-H1141

Plastic Flow Meters for gases & liquids, using TROGAMID* & POLYSULFONE Technology

Typical Aluminum GFM Mass Flow Meter

Material test chamber with mechanical convection

Messko. Messko. MTraB - Maintenance Free Dehydrating Breather Ordering specifications XX - XX - XXX - XX

Contactless Encoder RI360P0-QR24M0-INCRX2-H1181

Mini USB and USB 2.0-IP67 Connector System

Threaded Resistance Thermometers Model TR10-D, Miniature Design

Transcription:

Pressure switches for gas and air Pressure sensors line overview.0 Printed in Germany Rösler Druck Edition 08.00 Nr. 28 373 Page

Karl Dungs GmbH & Co. - The pressure switch specialists For decades we have been manufacturing pressure switches for a wide variety of applications. The original application field was firing systems followed by air-conditioning and ventilation systems as well as special machine tools. Today you can select a device tailored to meet your specific requirements from one of the largest pressure switch product lines. line overview of pressure switches for gas and air/contents Leaflet numbers Page 2 Short technical overview, conversion tables Page 3 overview Page 4 DDS differential pressure sensor Page Pressure switch as per EN 84 Page 6 Double pressure switch as per EN 84 Page 7 Pressure switch as per EN 84 Page 8 Pressure limiter as per EN 84 Page 8 Differential pressure limiter as per EN 84 Page 9 Vacuum switch as per EN 84 Page 9 Differential pressure switch as per EN 84 Page 0 DUNGS Klima-Set Page Centrifugal switch FW 00 / 2 as per EN 84 Page Pressure switch typeplates Page 2 For more detailed information, please refer to the leaflets listed below Pressure switch product line overview.00 High-pressure, gas and air pressure switches GW.0 Pressure switch GW A4.02 Pressure switch for multiple actuators GW A2.03 Differential pressure switch for air LGW A.04 Differential pressure switch for air LGW A2, LGW A2P.0 Differential pressure switch for air flue and exhaust gases LGW A4, LGW A4/2 (IP 6).07 Pressure switch for gas Differential pressure switch for air LGW C2. Differential pressure switch for air flue and exhaust gases LGW C3.4 Differential pressure sensor for gases and air DDS 9.0 Differential pressure switch for gas GGW A4. Klima-Set KS...C2.3 Centrifugal switch FW 00 / 2.08 Compact pressure switches GW A.2 Compact pressure switches GW A6.6 Page 2

Brief technical data pressures Temperature ranges Pressure switch for gas and air Refer to individual tables Ambient temperature: - C to +60 C Medium temperature: - C to +80 C Differential pressure switch for air Refer to individual tables Ambient temperature: - C to +8 C Medium temperature: - C to +8 C Important: Make sure that no condensate can enter into the pressure switch. Icing may occur at temperatures below zero and may lead to a malfunction or failure of the equipment. Materials -conveying housing: aluminium die casting Diaphragms: NBR basis Protective hood: polycarbonate, for GW../2 design hood made of die-cast aluminium Switching contacts: fine silver Special design: gold-plated fine silver Housing: polycarbonate Diaphragms: NBR or EPDM Switching contacts: fine silver or goldplated fine silver Electrical connection At terminal screws via PG cable gland, for 7 mm dia. to 2. mm dia. cables or plug connection with angle connector as per DIN 43 60, 3-pin and protective contact. Refer to individual tables At terminal screws via PG cable gland, for 7 mm dia. to 2. mm dia. cables or PG 9 For LGW...A and LGW...C3, flattype connector for 6.3 mm plug-in sleeves as per DIN 46 342 or plug connection with angle connector as per DIN 43 60, 3-pin and protective contact. Refer to individual tables Conversion table for pressure units Unit Name Pa bar mbar µbar N/mm 2 lbf/in 2 Pa = N/m 2 Pascal 0-0.0 0 0-6 0.0004 bar Bar 0 000 0 6 0. 4.037 mbar Millibar 00 0-3 000 0-4 0.04 µbar Microbar 0. 0-6 0-3 0-7 0.00004 N/mm 2 Newton per mm 2 0 6 0 0 4 0 7 4.03 lbf/in 2 (psi) pounds per square inch 6894.76 0.0689 68.9 68948 0.00689 Page 3

overview Pressure switches for gases and air, p max mbar LGW A4/2 Square shape IP 6 Die-cast hood Epoxy coating G /4 threaded connection Switching pressure adjustable by hand wheel GW...A2 Square shape pressure switch for DUNGS multiple actuators O ring flange connection GW...A3 Square shape pressure switch for multiple actuators O ring flange connection GW...A4 Square shape pressure switch G /4 threaded connection Switching pressure adjustable by hand wheel GW A Rectangular shape Compact pressure switch for DUNGS multiple actuators O ring flange connection GW A6 Rectangular shape Compact pressure switch G /4 threaded connection Switching pressure adjustable by hand wheel Double pressure switches for gases and air (Überdruckbereich) GW...A6/...A6 Rectangular shape Flanged single housings Switching pressures adjustable by hand wheel Pressure switches for gases and air, p max 2,0 bar, Metallmembrane GW /2000/0 A4 Round shape G /4 threaded connection Switching pressure adjustable by hand wheel GW A4/2, GW 2000 A4/2, GW 0 A4/2 Pressure limiters for gas and air NB...A2 Square shape Interlocked as pressure falls Pressure switch for DUNGS multiple actuators NB...A4 Square shape Interlocked as pressure falls Switching pressure adjustable by hand wheel Compact pressure switch ÜB...A2 Square shape Interlocked as pressure rises Pressure switch for DUNGS multiple actuators ÜB...A4 Square shape Interlocked as pressure rises Switching pressure adjustable using hand wheel Compact pressure switch Differential pressure switches for gases and air GGW A4 Square shape Differential pressure switch for gas in pressure range G /4 and G /8 threaded connections Switching pressure adjustable by hand wheel GGW A4/U Square shape Differential pressure switch for gas in vacuum range G /4 and G /8 threaded connections Switching pressure adjustable by hand wheel LGW A4 Square shape Differential pressure switch for air, pressure switch for gas G /4 and G /8 threaded connections Switching pressure adjustable by hand wheel Differential pressure switches for air LGW...A Square shape Fixed adjustment at factory Connection for 4 mm dia. hose LGW...A2 Square shape Switching pressure adjustable by hand wheel Connection for 4 mm dia. hose LGW...A2P Square shape Test button Switching pressure adjustable by hand wheel G /4 (tapered) and G /8 threaded connections LGW...C2 Round shape Large diaphragm diameter Switching pressure adjustable by hand wheel Connection for 4 mm dia. and 6 mm dia. hoses LGW...C3 Round shape Fixed adjustment at factory Connection for 6 mm dia. hose LGW...A4/2 Square shape IP 6 Die-cast hood Powder-coated G /4 and G /8 threaded connection Switching pressure adjustable by hand wheel Klima-Set (differential pressure switch for ventilation and air-conditioning systems with complete range of accessories) KS...C2 Round shape Switching pressure adjustable by hand wheel Suitable for DDC applications Electronic differential pressure sensor for gases and air DDS Non-contacting transformer (pressure to voltage) with continuous output 0-0 V Round shape, aluminium version Different measuring ranges possible G /8 threaded connection Page 4

Differential pressure sensor for gas and air Pressure sensor in compliance with DIN 3398. For gases of families, 2, 3 and other neutral media. Differential pressure sensor DDS 00-M2 DDS 0-M2 DDS -M2 2 02 26 38 2 0 Setting ranges [Pa] 0-00 0-0 0 - pressure [kpa] DDS 000-M2 2 06 0-000 DDS -M2 2 07 0 - DDS 3000-M2 23 33 0-3000 Differential pres- DDS 00-M2 sure sensor with DDS 0-M2 mounting DDS -M2 kit DDS 000-M2 29 099 29 02 29 0 29 08 0-00 0-0 0-0 - 000 DDS -M2 29 0 - DDS 3000-M2 23 284 0-3000 Mounting kit, complete 26 992 Mounting bracket 230 288 Connection hose ø 4 (0 x) 230 303 DDS P + P2 p p U,(I) Switching modules SM-ES-220 VAC p SM-ES-24 VAC SM-ES-24 VAC 2 3 4 6 7 8 9 2 3 4 6 7 8 9 2 3 4 6 7 8 9 2 3 4 6 7 8 9 Blower errors DDS Filter exchange required Forced switch-off Page

Pressure switch for firing systems Pressure switch as per EN 84 for gases of families, 2, 3 and other neutral gaseous media. EU type test approval as per EU Appliance Directive. Pressure switch for gas and air GW 3 A2 GW 0 A2 Setting ranges [mbar] 2 230 2 23 Switching difference p [mbar] 0,3 0, pressure [mbar] GW 0 A2 2 232 2, - 0 [AG G3 V2] GW 0 A2 GW 0 A2 GW 0 A2 2 233 2 234 2 23-0 - 0 30-0 GW A2 2 236 00-0 GW 0 A3,0 IP 00-4 0 GW 0 A3 2, - 0 2, IP 00-4 0 GW 00 A3 20-00 8,0 IP 00-4 0 GW 3 A 229 20 0,7-3 0,7 [AG G3 V2] GW 0 A GW 0 A GW 0 A 22 938 22 939 22 940 2-0 - 0 0-0 2, GW A 227 639 00 - [AG M MS9 V0 VS3] GW A4/2 237 804 00-0 IP 6 Pressure switch symbol GW A LGW A4/2 Page 6

Pressure switch for firing systems Double pressure switch as per EN 84 for gases of families, 2, 3 and other neutral gaseous media. EU type test approval as per EU Appliance Directive. Setting ranges [mbar] Switching difference p [mbar] pressure [mbar] Pressure switch for gas and air GW 3 A6 GW 0 A6 228 723 228 724 0,7-3 2-0 0,7,0 [AG G3 MS9 V0] GW 0 A6 GW 0 A6 GW A6 228 72 228 726 228 727-0 0-0 00-2, Double pressure switch for gas and air GW3A6/3A6 GW3A6/0A6 GW0A6/0A6 229 23 229 236 229 237 0,7-3 0,7-3 0,7-3 2-0 2-0 2-0 0,7 0,7 0,7,0,0,0 GW0A6/0A6 229 238 2-0 - 0,0 2, [MIN: G3 M9 VS3 VS0] [MA: G3 MS9 V3 V0] GW0A6/0A6 229 239 GW0A6/0A6 229 240 GW0A6/0A6 229 24 GW0A6/0A6 229 242 2-0 0-0 - 0-0 - 0 0-0 0-0 0-0,0 2, 2, 2,,0 GWA6/A6 229 243 00-00- Pressure switch for firing systems Pressure switch as per DIN 3398, DIN EN 3398, Part 3 and DIN EN 84 for gases of families, 2, 3 and other neutral gaseous media. EU type test approval as per EU Appliance Directive. Setting ranges [mbar] Switching difference p [mbar] pressure [mbar] Pressure switch GW A4 GW A4/2 232 034 232 0 00-00 - IP 6 2000 2000 GW 2000 A4 GW 2000 A4/2 232 037 232 06 300-2000 300-2000 0 0 IP 6 4000 4000 GW 0 A4 GW 0 A4/2 232 039 232 07 000-0 000-0 00 00 IP 6 7200 7200 GW 0 A2 GW A6 LGW 0 A4 Page 7

Pressure switch for firing systems Pressure switch as per DIN 3398, Part, EN 84 for gases of families, 2, 3 and other neutral gaseous media. EU type test approval as per EU Appliance Directive. Setting Switching difference ranges [mbar] p [mbar] pressure [mbar] Pressure limiter [AG G3 V2] NB 0 A2 NB 0 A2 NB A2 2 237 2 240 2 24 2, - 0 30-0 00 - NB 0 A4 20 34 2, - 0 [AG PG MS9 V0] NB 0 A4 NB A4 20 93 20 97 30-0 00 - Pressure limiter [AG G3 V2] ÜB 0 A2 ÜB 0 A2 ÜB A2 2 242 2 24 2 246 2, - 0 30-0 00 - ÜB 0 A4 20 37 2, - 0 [AG PG MS9 V0] ÜB 0 A4 ÜB A4 38 630 20 970 30-0 00 - ÜB 0 A4 LGW 3 A2 LGW 3 A2 P Page 8

Pressure switch for firing systems Differential pressure switch as per EN 84 for gases of families, 2, 3 and other neutral gaseous media. EU type test approval as per EU Appliance Directive. Setting Switching difference ranges [mbar] p [mbar] pressure [mbar] Pressure GGW 3 A4 232 08 0,3 [AG M MS9 V0 VS3 NH 3 best.] GGW 0 A4 GGW 0 A4 GGW 0 A4 232 09 232 0 232 2, - 0 30-0 0, Vacuum GGW 3 A4-U 232 99-0,4 - -3 0,3 [AG M MS9 V0 VS3 NH 3 best.] GGW 0 A4-U GGW 0 A4-U GGW 0 A4-U 232 992 232 993 232 994 - - -0-2, - -0-30 - -0 0, LGW A LGW C2 LGW C3 Page 9

Differential pressure switches for air, flue and exhaust gases in firing systems Differential pressure switches per DIN 3398 Part 2; LGW A4 DIN EN 84 EU type test approval as per EU Appliance Directive. Setting Switching difference ranges [mbar] p [mbar] pressure [mbar] Differential pres- LGW 3 A sure LGW 0 A switch for air LGW 0 A 2, - 0 0,3 0, 00 00 00 LGW 3 A2 07 409 0,3 [AG PG V9] LGW 0 A2 LGW 0 A2 07 47 07 42 2, - 0 0, LGW 0 A2 07 433 30-0 LGW 3 A2P 20 204 0,3 [AG PG V9] LGW 0 A2P 20 22 LGW 0 A2P 20 220 2, - 0 0, LGW0 A2P 20 238 30-0 LGW 3 A4 22 90 0,3 ** [AG PG MS9 VS3 V0] LGW 0 A4 LGW 0 A4 LGW 0 A4 22 9 22 92 22 93 2, - 0 30-0 0, ** ** ** [AG PG V3] LGW, C2 LGW 3 C2 LGW 0 C2 22 200 22 7 22 72 0,2 -, 0,2 0,3 0, 0 0 0 LGW, C3 0,2 -, 0,07-0,3 0 LGW 3 C3 0,2-0,4 0 LGW 0 C3 0,20-0,6 0 LGW 3 A4/2 232 04 0,3 ** [AG M MS9 V0] LGW 0 A4/2 232 046 LGW 0 A4/2 232 048 LGW 0 A4/2 232 00 2, - 0 30-0 0, ** ** ** * optionally IP 42 or IP 20. Pressure switch with IP 0 or IP 20 must be installed so that degree of IP 44 is ensured during operation. ** applies only to connection to G /4, lower pressure chamber Page 0

Pressure switch for ventilation and air-conditioning systems Differential pressure switch for air DUNGS Klima-Set with complete mounting kit Setting ranges [Pa] Switching difference p [Pa] pressure [kpa] Klima-Set KS 0 C2 27 773 20-0 8 KS 300/ C2 224 390 20-300 20 KS 300 C2 27 774 40-300 20 KS C2 226 88 30-2 KS C2 27 77 70-0 KS 000 C2 27 776 00-000 40 Mounting kit KS for 3000 KS...C2 complete 27 777 supplied 20-3000 80 Extension tube Hose connection Drilling template Mounting screws 4 x.x2000 mm dia. connection hose Centrifugal switch supply loss for forced-air burner and ventilator motors as per DIN 32 726 DIN-tested and registered to DIN-DVGW Speeds Electrical data Centrifugal switch FW 00/2 FW 00/2 20 32 2 23 IP 44 Switch-on speed (as speed increases), DIN 32 726: n 26 rpm - Switch-off speed (as speed decreases), DIN 32 726: n 260 rpm - Special speeds on request Range: 800-4000 rpm Voltage: 220 VAC Nominal current: A (ohmic load) FW 00/2 KS Page

Pressure switches for gas and air Pressure sensors plates pressure typeplate All the information is indicated on the pressure switch setting wheel. The setting wheel for gas pressure switches is always yellow. s: GW...A2, GW...A4, GW...A, GW A6, ÜB A2, ÜB A4, NB A2, NB A4 3 4 2 6 7 mbar GW 0 A2 Range,0-0 mbar p mbar max. ID-No.: CE-008 AP 070 8 0 9 Set switching pressure Version Setting range pressure CE-number plate for differential pressure switches for gases and/or air The setting wheel for gas pressure switches is yellow. It is always blue for differential pressure switches for air. s: LGW, LGW...A2, LGW...A2P, LGW...A4, LGW...C2, KS C2 0,9,2, 0,6,8 0,4 2, mbar Set switching pressure LGW 3 A2 Version p max. mbar ~(AC) 0 A 20 V Setting range CE-008 AQ 0673 2,4 2,7 3 CE-number Differential pressure switches for air, flue and exhaust gases The LGW...A differential pressure switch is only manufactured to customer-specific switching values. Each differential pressure switch therefore has an individual typeplate. The typeplate is affixed to the equipment. Switching pressure max. operating pressure Adjusted as pressure falls LGW 3 A,2 mbar p pmax. 0 mbar ID-Nr. CE-008 AQ 0673 CE-number Installation position We reserve the right to make any changes in the interest of technical progress. Head Offices and Factory Karl Dungs GmbH & Co. Siemensstraße 6-0 D-73660 Urbach, Germany Telephone +49 (0)78-804-0 Page 2 Telefax +49 (0)78-804-66 Postal address Karl Dungs GmbH & Co. Postfach 2 29 D-73602 Schorndorf, Germany e-mail info@dungs.com Internet www.dungs.com