VIESMANN VITOSOL 200-F Flat-plate collectors for the utilisation of solar energy



Similar documents
VIESMANN. Datasheet Part numbers and prices: see pricelist VITOSOL 200-F. Flat-plate collector for the utilisation of solar energy

Data Sheet VITOSOL 100. Flat collectors for the utilisation of solar energy. Vitosol 100. Part nos. and prices: see price list

VIESMANN VITOSOL. Technical guide VITOSOL 100-F VITOSOL 200-T VITOSOL 200-F VITOSOL 200-T VITOSOL 200-F VITOSOL 300-T VITOSOL 200-F, 300-F

VITOSOL r 200-T SP2A. VITOSOL 200-T Type SP2A

VITOSOL. Solar heating systems Flat-plate and tube collectors

Solar Thermal Systems

Drain Back systems Made in Germany

Test Report No. C829QPEN

Harness Your Energy NOW AVAILABLE! the new. ASW-58A-22/30 Solar Thermal Collector

HDA

VIESMANN. Installation and service instructions VITOTROL 100. for contractors

Test Report No. C1319LPEN

Sustainable water heating solutions through solar systems

UniPlate. Solar Collectors SOLAR SYSTEMS.

ECOCIAT. Domestic hot water heat recovery unit

Test Report No. C908LPEN

Test Report No. C926LPEN

maximise the sun s energy with warmflow solar Warmflow Solar

Solar heating from Viessmann: efficient systems for the utilization of solar energy

PHOTOVOLTAIC (PV) solar panels. Specification. Electricity - CE & ISO 9000 certified. 83W panel. 180W panel Maximum power:

System Design Guidelines

Heating with Solar Energy

PRO-CLEAN. Technical Description. Specifications. Space-saving design with minimum heat loss (melamine resin insulation)

How To Buy A Designo Grille

Solar hot water systems that give energy efficiency a whole new meaning

Dispelling the Solar Myth - Evacuated Tube versus Flat Plate Panels. W illiam Comerford Sales Manager Ireland Kingspan Renewables Ltd.

SERVER ROOM CABINET INSTALLATION CONCEPTS

Installation Instructions

BLADE S-MAX Cabinet for Blade Server

PPS-PPQ-BT-PIAS RESIN INSULATORS FOR OIL INSULATED ELECTRICAL MACHINES

1-Way Chilled Water Cassettes KCO 60, 90 & 120. Technical Brochure. TM KCO-W.1GB Date : November 2005 Supersedes : None

SECTION PACKAGED ROOFTOP AIR CONDITIONING UNITS NON-CUSTOM

Art.S001-S002 SOLAR MODULE WITH DELIVERY AND RETURN CONNECTIONS

19 DYNAmax Free Standing Server C A B I N E T s

Cooking at the Speed of light!

Technical guide. Solar thermal systems

Brochure EX

The Greenskies range of solar panels from Worcester. Technical and specification information. Greenskies solar kits now available to order NEW

K17.12 Door closers K17. Doors

Morgue refrigeration unit

Installation, operation and maintenance manual TX 35A


MFP14, MFP14S and MFP14SS Automatic Pumps

LindabAtriumPlana. Heating and cooling panels. lindab atrium plana. lindab we simplify construction

HARTING Ethernet Cabling 8-poles Overview

Thermostatic actuator RAVK - for 2-way valves RAV-/8 (PN 10), VMT-/8 (PN 10), VMA (PN 16) - for 3-way valves KOVM (PN 10), VMV (PN 16)

SOLAR HOT WATER SOLUTIONS stainless steel roof systems

19 DYNAmax Free Standing Server C A B I N E T s

Windows, French doors, folding windows, terrace doors SFB 1074 with low U-values

(This report is endorsed) Industrivej 20, 9900 Frederikshavn, Danmark

Direct steam injection humidifiers

Thermostatic actuator RAVK - for 2-way valves RAV-/8 (PN 10), VMT-/8 (PN 10), VMA (PN 16) - for 3-way valves KOVM (PN 10), VMV (PN 16)

ECOplus Solar Cylinder

2-Port Self-acting Temperature Control Valve Selection for Heating and Cooling Applications

solarplus solar systems general features

Price List Rev.2. AGUIDROVERT S.L. c/ Cervantes 20, Zaragoza (Spain) Tel.: Fax:

CRAC Precision climate control units for data centres

Thermostatic actuator RAVV - for 2-way valves RAV-/8 (PN 10), VMT-/8 (PN 10), VMA (PN 16)

DIESEL-FUELED, BLOWN AIR, DUCTABLE HEATERS

Worth noting. Use. Key figures. Installation. lindab atrium - loggia

Airline. small air handlers and extract fan units. VES Airline part of a complete range of innovative, flexible products from the HVAC experts

CDW Systems Ltd Contemporary Doors & Windows

FLEXCON EXPANSION VESSELS. Flamco FLEXCON Flexcon. Expansion vessels FLEXCON FLEXCON M. Flamco FLEXCON V-B.

RPV - RP - RA air handling units

Under sill units. Type FSL-B-ZAS

HARTING Ethernet Cabling 4-poles Overview

CALEFFI. Compact automatic flow rate regulator with polymer cartridge. 127 series 01166/09 GB

SD. Flat roof. Rack Mounting. Installation instructions (2010/11) AU

Geothermal Alliance of Illinois. TXVs Theory and Fundamentals John Haug Senior Application Engineer Emerson Climate Technologies - Flow Controls

LED LEONARDO 120 W. LED Fresnel SPOTLIGHT White light, either Tungsten or Daylight balanced Correlated Color Temperature

play Playful warmth, colourful comfort

THERMOSYPHON HOT WATER SYSTEM IN THE FIJI ISLANDS. We are located about 3000KM South west of Australia and in the middle of the Pacific ocean!

SOLAR WATER HEATER USER AND INSTALLATION MANUAL

BB-18 Black Body High Vacuum System Technical Description

Dow Corning PROPRIETARY. Dow Corning. A Thermal Modelling Comparison of Typical Curtain Wall Systems

39HQ Airovision Air Handling Units

DIGITUS Network & Server Cabinets. UNIQUE Series

Installation instruction of the flat solar collectors models ES1V2.0, ES1V2.65, ES2V/2.0 AL, EM2V/2.0, ES2V/2.65, ES2H/2.65 on the inclined tile roof.

Installation manual Pitched Roof Clamp System

Active Solar Thermal Energy Applications in Buildings (Part 1)

Making Your Home Ready For Solar Water Heating

How To Build A T7 Rack For Information Technology

James M. Pleasants Company

BER Assessors Dwellings Technical Bulletin

Cold Room & Refrigeration System (Casserole Assembly) No of units: 1

SOHOline and SOHO Slimline The SOHOline and SOHO Slimline offer a modular, sturdy and compact design

!!!!!! !!! Decra Plus DPSW010 DPSTW011 DPSW012 DPSW013 DPSW014 DPSW015 DPSW016 DPSW020 DPSW021 DPSW024 DPSW030 DPSW031 DPSW035 DPSW030 DPSW031 DPSW035

Vicot Solar Air Conditioning. V i c o t A i r C o n d i t i o n i n g C o., l t d Tel: Fax:

Knürr Smaract. Knürr Smaract. CompactRack

Installation Instructions

3/2-way Solenoid Valve, direct-acting, NC or NO

Installation Manual. Thermomax Solar Water Heater ... Installation Procedure for Flatroof and Ground. Revision 8

VAD. Variable Area Desuperheaters

Installation Manual. Solar Pool Heating System. Read the complete manual before beginning the installation

STAYFLEX CORROSION CONTROL AND THERMAL INSULATION SYSTEM

Installation and Service Instructions. Neutralization System Part no Grünbeck part no

NEW. Conventional gas fired boilers open vented / sealed unvented. > 94% (Hi) CGU-2 / CGU-2K CGG-2 / CGG-2K

High-efficient gas boiler CompactGas

Installation Detailed installation instructions are provided which should be strictly followed.

Professional Report. Map section. Location of the system. Valkkinen Longitude: Latitude: Elevation: 89 m

Transcription:

VIESMANN VITOSOL 200-F Flat-plate collectors for the utilisation of solar energy Datasheet Part no. and prices: see pricelist VITOSOL 200-F Type SV2A/B and SH2A/B Flat-plate collector for vertical or horizontal installation, for installation on flat and pitched roofs as well as for integration into roofs and freestanding installation. Type SH2A/B also for walls. VITOSOL 200-F Type 5DIA Large area flat-plate collector for integration into pitched pantiled roofs. 5/2013

Product description Vitosol 200-F, type SV2A/B and SH2A/B The main component of the Vitosol 200-F, type SV2A/SH2A is the highly selectively coated absorber. It ensures a high absorption of insolation and low emission of thermal radiation. A meander-shaped copper pipe through which the heat transfer medium flows is part of the absorber. The heat transfer medium absorbs the absorber heat through the copper pipe. The absorber is encased in a highly insulated collector housing that minimises the thermal losses of the collector. The high-grade thermal insulation provides temperature stability and is free from gas emissions. The cover comprises a solar glass panel. The glass has a very low iron content, thereby reducing reflection losses. Up to 12 collectors can be combined together to create a single collector array. For this purpose, the standard delivery includes flexible connecting pipes with O-rings. A connection set with locking ring fittings enables the collector array to be readily connected to the pipes of the solar circuit. The collector temperature sensor is mounted in a sensor well set in the solar circuit flow. The Vitosol 200-F, type SV2B/SH2B with a special absorber coating is designed for coastal regions (see chapter "Specification"). A B C D E F G H K A Solar glass cover, 3.2 mm B Aluminium cover strip C Pane gasket D Absorber E Meander-shaped copper pipe F Melamine epoxy foam insulation G Melamine epoxy foam insulation H Aluminium frame in RAL 8019 K Steel bottom plate with an aluminium-zinc coating Product description Vitosol 200-F, type 5DIA The main component of the Vitosol 200-F, type 5DIA, is the absorber designed with a selective coating. It ensures a high absorption of insolation and low emission of thermal radiation. A copper pipe through which the heat transfer medium flows is fitted to the absorber. The heat transfer medium absorbs the absorber heat through the copper pipe. The absorber is encased in a highly insulated collector housing that minimises the thermal losses of the collector. The high-grade thermal insulation provides temperature stability and is free from gas emissions. The collector is covered with a solar glass panel. The glass has a very low iron content, thereby reducing reflection losses. At the back of the collector are flexible, thermally insulated flow and return pipes as well as the sensor well for the collector temperature sensor. Vitosol 200-F, type 5DIA, designed for roof integration. F E D C B A G H K A Conduit for sensor lead B Flexible connecting pipe with thermal insulation C MDF board D Thermal insulation E Reinforcing frame F Rubber seal G Solar glass cover 2 VIESMANN VITOSOL 200-F

Product description Vitosol 200-F, type 5DIA (cont.) H Cover strip K Absorber Benefits Vitosol 200-F, type SV2A/B and SH2A/B Powerful flat-plate collector with a highly selectively coated absorber. Absorber designed as meander layout with integral headers. Up to 12 collectors can be linked in parallel. Universal application for above roof and freestanding installation either in vertical (type SV) or horizontal (type SH) orientation. Type SH is suitable for installation on walls. Attractive collector design; frame in RAL 8019 (brown). Upon request, the frame is also available in all other RAL colours. The selectively coated absorber, the highly effective thermal insulation and the cover made from low ferrous solar glass ensure a high solar yield. Permanently sealed and highly stable through all-round folded aluminium frame and seamless pane seal. Puncture-proof and corrosion-resistant back panel. Easy to assemble Viessmann fixing system with statically-tested and corrosion-resistant components made from stainless steel and aluminium standard for all Viessmann collectors. Quick and reliable collector connection through flexible corrugated stainless steel pipe push-fit connectors. Benefits Vitosol 200-F, type 5DIA Large area flat-plate collector with selective coating. High efficiency through highly selectively coated absorber, integral piping and highly effective insulation. Absorber area: 4.75 m 2 Quick installation due to the flashing frame fitted onto the collector for roof integration, flexible connection lines and lifting eyes. VITOSOL 200-F VIESMANN 3

Specification Vitosol 200-F, type SV2A/B and SH2A/B Vitosol 200-F is available with 2 different absorber coatings. Type SV2B/SH2B has a special absorber coating that allows these collectors to be used in coastal regions. Note Viessmann accepts no liability if type SV2A/SH2A is used in such regions. Distance to the coast: up to 100 m: only use type SV2B/SH2B between 100 and 1000 m: type SV2B/SH2B is recommended Type SV2A SH2A SV2B SH2B Gross area m 2 2.51 (required when applying for subsidies) Absorber area m 2 2.32 Aperture area m 2 2.33 Installation position (see following diagram) A (above roof and roof integration), C, D B (above roof and roof integration), C, D, E A (above roof and roof integration), C, D B (above roof and roof integration), C, D, E Clearance between collectors mm 21 Dimensions Width mm 1056 2380 1056 2380 Height mm 2380 1056 2380 1056 Depth mm 90 90 90 90 The following values apply to the absorber area: Optical efficiency % 79.3 78.3 Heat loss factor k 1 W/(m 2 K) 4.04 4.07 Heat loss factor k 2 W/(m 2 K 2 ) 0.0182 0.016 Thermal capacity kj/(m 2 K) 5.0 4.6 Weight kg 41 Liquid content litre 1.83 2.48 1.83 2.48 (heat transfer medium) Permiss. operating pressure bar/mpa 6/0.6 (see chapter "Solar expansion vessel") Max. stagnation temperature C 186 185 Steam output Favourable installation position W/m 2 60 Unfavourable installation position W/m 2 100 Connection Ø mm 22 B A C E D 4 VIESMANN VITOSOL 200-F

Specification Vitosol 200-F, type SV2A/B and SH2A/B (cont.) 1056 90 51 KV 90 2380 2200 KR Type SV2A/SV2B KR Collector return (inlet) KV Collector flow (outlet) 2380 90 51 KV 90 1056 876 KR Type SH2A/SH2B KR Collector return (inlet) KV Collector flow (outlet) Specification Vitosol 200-F, type 5DIA Specification Gross area m 2 5.41 Absorber area m 2 4.75 Aperture area m 2 4.92 Dimensions Width mm 2578 Height mm 2100 Depth mm 109 VITOSOL 200-F VIESMANN 5

Specification Vitosol 200-F, type 5DIA (cont.) Optical efficiency % 78.5 Heat loss factor k 1 W/(m 2 K) 4.10 Heat loss factor k 2 W/(m 2 K 2 ) 0.0065 Thermal capacity kj/(m 2 K) 6.4 Weight kg 105 Liquid content litre 4.2 (heat transfer medium) Permiss. operating pressure bar/mpa 6/0.6 Max. stagnation temperature C 220 Connection Ø mm 22 Requirements of base structure and fixings with sufficient ballast to counteract prevailing wind forces 2809 2649 110 2578 A B C 2391 2100 211 D E A Collector B Flashing frame C Transport frame D Hydraulic connections E Aluminium apron Tested quality Approved quality The collectors meet the requirements of the "Blue Angel" certificate of environmental excellence to RAL UZ 73. Tested in accordance with Solar KEYMARK and EN 12975. CE designation according to current EC Directives. 6 VIESMANN VITOSOL 200-F

VITOSOL 200-F VIESMANN 7

Subject to technical modifications. Viessmann Werke GmbH&Co KG D-35107 Allendorf Telephone: +49 6452 70-0 Fax: +49 6452 70-2780 www.viessmann.com Viessmann Limited Hortonwood 30, Telford Shropshire, TF1 7YP, GB Telephone: +44 1952 675000 Fax: +44 1952 675040 E-mail: info-uk@viessmann.com 8 VIESMANN VITOSOL 200-F