Protect IT MNS Motor Management INSUM. MPU - Multi Purpose Unit. - Catalogue - ABB



Similar documents
Shutter Actuator Standard, 4-fold, 230 VAC, MDRC RA/S , GH Q R0111. ABB i-bus EIB

mecotron Safety relay ESTOP-2 For emergency stop monitoring

Your Advantages For safety application up to PL e / Cat. 4 e.g. SIL 3 Manual or automatic start * see variants. Applications.

AC 800M. EtherNet/IP DeviceNet Linking Device LD 800DN. Power and productivity for a better world TM SP1134

Analogue Input, 4-fold, MDRC AE/S 4.1, GH Q R0001

T-05-S2. Rotary drive without spring return. Technical data sheet. Description. Technical data. Actuators

RM35UA13MW. range V. Main. Product or component type. Relay monitored parameters

Positive-guided relay outputs: 3 safety contacts (N/O), instantaneous. 1 auxiliary contact (N/C), instantaneous

225C-024T-05. Continuous control rotary drive without spring return. Technical data sheet. Description. Technical data. Actuators

Switch Actuator, 8-fold, 10 A, MDRC AT/S , GH Q R0111

RISH CON - Hz. Salient Features : Application : Product Features: FREQUENCY TRANSDUCER

Control Devices Catalogue. Control Devices. Preferred and Standard Products

ABB i-bus KNX Fan Coil Actuator, MDRC FCA/S 1.1M, 2CDG R0011

N20xxA, N34xxA NON-SPRING RETURN DIRECT-COUPLED DAMPER ACTUATORS FOR FLOATING AND 2-POSITION CONTROL

RM17TE V AC. Main. Product or component type. Product specific application. Relay monitored parameters 250 V DC 5 A DC

IMR 6000/10../20../30

Pluggable interface relays CR-P Pcb relays

Modular I/O System Analog and Digital Interface Modules

Electronic overload relay EF19 and EF45

Safety technique. Emergency stop module BO 5988 safemaster

SUBJECT: How to wire a motor starter Number: AN-MC-004 Date Issued: 2/08/2005 Revision: Original

Calculation of the Current Transformer Accuracy Limit Factor Application Note

Type: EASY719 DC RC Article No.: Ordering information Relay outputs Quantity 6 Power supply V DC 24 V DC. Description

Documentation for. KL2602 and KL2622. Two-channel Relay Output Terminals for 230 V AC / 30 V DC. Version: 1.4 Date:

MONITORING RELAYS. w VOLTAGE MONITORING RELAY UR5U1011. w SCHRACK-INFO. w TECHNICAL DATA

Safety automation solutions

80 Series - Modular timers 16 A. Features

Technote. Frese OPTIMA Compact actuators DN10-DN32. Application. Features thermic actuators. Features motoric actuators. Approval.

Electronic timer CT-VBS OFF-delayed without auxiliary voltage, for DC contactors Data sheet

ABB 1. Three-phase monitoring relay CM-PFS. Data sheet. Features. Approvals. Marks. Order data. Order data - Accessories. Application.

Single-phase ( V) voltage monitoring: Undervoltage Overvoltage Window mode (overvoltage + undervoltage) Voltage fault memory selectable

HSP GmbH Zum Handwerkerhof Wendelstein Tel / Fax: / Web: HSP@hsshsp.de NTG-3000.

ABB i-bus EIB Shutter Actuators JA/S , JA/S , JA/S , JA/S M, JA/S M, JA/S

Safety Relays ESM/ESM-F

CONFIGURABLE SAFETY RELAYS

Technical data. General specifications. Signal voltage V DC Signal duration. 1 s Input 2. Signal voltage. 1 s Analog output.

Inductive Sensors Single or Dual Loop Detectors Type LD with teach-in

TECHNICAL DATASHEET #TD1404AX PWM CONTROLLED SOLENOID DRIVER

W DATA SHEET: RESIDUAL CURRENT CIRCUIT BREAKER A, SERIES BCF0 AND BCF6

ABB i-bus KNX Switch Actuator, x-fold, 16 A, MDRC SA/S x , 2CDG1101xxR0011

Speed Control Relays SX2

Automation System TROVIS 6400 TROVIS 6493 Compact Controller

Electronic overload relay EF65, EF96 and EF146

ABB Drives. User s Manual. Pulse Encoder Interface Module RTAC-01

LC1D65AM7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 65 A V AC coil

Power consuption Motor (Motion) Power consuption Standby (end position) 1,0 W. Position feedback - Switching point

H/L = Power supply. FN = Nominal Frequency. RN = Rated value of output burden. UN = Nominal input voltage. IN = Nominal input current.

PSR The compact range Description

Installation manual. Generator Paralleling Controller GPC multi-line C

CONFIGURABLE SAFETY RELAYS

Products and solutions for lifting systems

38 Series - Relay interface modules A

Voltage Regulator SPAU 341 C. Product Guide

Air damper actuators

DMX2PWM 9 Channel Dimmer Setup Manual

Quick Connect. quick - simple - efficient.

48 SERIES Relay interface modules 10 A

Current valve. for AC 24 V pulse/pause control of electrical loads up to 30 kw

PCS0100en Persy Control Services B.V. Netherlands

Catalog. Modular DIN rail components Installation contactors

Data sheet GIOD.1 Input/output module with CAN bus. ERP no.: Data sheet GIOD.1 V_3.0

ABB 1 NEW. Three-phase monitoring relay for grid feeding CM-UFS.1. Data sheet. Features. Approvals. Marks. Order data. Order data - Accessories

SMS 4 / SMS 5 safety mat Product information

AC/DC Power Modules C B. TML Series, 20 & 40 Watt. Features. 20 Watt Models

Series /16 DIN Multi-Mode Bar Graph Display Timer TIMERS PRODUCT HIGHLIGHTS

Quick running actuator

Voltage monitoring relays CM-ESS.2 For single-phase AC/DC voltages

RISH EM 3490 DS Dual Source Energy Meter RISH EM 3490 DS. Application : Product Features:

Solid State Timers Type F

Specifications for EM VDC 4 In/4 Out and EM VDC 4 In/4 Relay Out

38 Series - Relay interface modules A

PHOENIX CONTACT Features

DMX-K-DRV. Integrated Step Motor Driver + (Basic Controller) Manual

Telephone- and leased line modem for industrial applications TD-36

Installation Manual (English) Adjustable Active DP Terminator T1-Pepper Active RS485 segment termination for non-compliant cable

Three-phase monitoring relay CM-PFE

3RT1015-1BB41 CONTACTOR, AC-3 3 KW/400 V,

E-STOP relays, safety gate monitors

IO-RM3 3-Stage Relay Module

PNOZsigma - Base units

Type: DILM115(RAC240) Article No.: Sales text Contactor,55kW/400V,AC operated. Ordering information

Cable Plug acc. to DIN EN , Form A

VEO. V4PF480Y/277VSYTK02 Art.Nr.: V4PF480Y/277VSYTK02P Art.Nr.: TECHNICAL DATA

JNIOR. Overview. Get Connected. Get Results. JNIOR Model 310. JNIOR Model 312. JNIOR Model 314. JNIOR Model 410

Softstarters Type PSR

HERZ-Thermal Actuators

Electric Rotary Actuator - On/Off or programmable control actuator

RM4TG20 three-phase network control relay RM4-T - range V

ABB Drives. User s Manual HTL Encoder Interface FEN-31

CONTROLS DATA MANAGEMENT PROCESS AUTOMATION EUROCUBE. General purpose single phase thyristors and solid state relays Product data.

0.8 U N /0.5 U N 0.8 U N /0.5 U N 0.8 U N /0.5 U N 0.2 U N /0.1 U N 0.2 U N /0.1 U N 0.2 U N /0.1 U N

AUTOMATIC TRANSFER SWITCH. Changeover Type from 250A to 2500A

Bimetallic Overload Relay Specifications

TM7BDM8B expansion block - TM7 - IP67-8 DI/DO - 24V DC A - M8 connector

Vert-X 16-5V / % Ub. Applications Servodrives Dancer arm Operating table

CONNECTOR AMPLIFIER FOR PROPORTIONAL VALVES (4-20 ma Input Version)

Process modules Digital input PMI for 24 V DC inputs for 120 V AC inputs

Electronic timer CT-AHD.12 OFF-delayed with 1 c/o (SPDT) contact

E-STOP relays, safety gate monitors

Disturbance Recoder SPCR 8C27. Product Guide

Transcription:

Protect IT MNS Motor Management INSUM MPU - Multi Purpose Unit - - ABB

INSUM Multi Purpose Unit Revision 1.6 2

NOTICE The information in this document is subject to change without notice and should not be construed as a commitment by ABB Schaltanlagentechnik GmbH. ABB Schaltanlagentechnik GmbH assumes no responsibility for any errors that may appear in this document. In no event shall ABB Schaltanlagentechnik GmbH be liable for direct, indirect, special, incidental, or consequential damages of any nature or kind arising from the use of this document, nor shall ABB Schaltanlagentechnik GmbH be liable for incidental or consequential damages arising from use of any software or hardware described in this document. This document and parts thereof must not be reproduced or copied without ABB Schaltanlagentechnik GmbH s written permission, and the contents thereof must not be imparted to a third party nor be used for any unauthorized purpose. Permission to translate the document shall be obtained from ABB Schaltanlagentechnik GmbH. The translated document shall be sent to ABB Schaltanlagentechnik GmbH together with the confirmation that the content of the document is the same. The software described in this document is furnished under a license and may be used, copied, or disclosed only in accordance with the terms of such license. 2004 ABB Schaltanlagentechnik GmbH, Germany TRADEMARKS MNS and INSUM are registered trademarks of ABB Schaltanlagentechnik GmbH Microsoft, Windows and Windows NT are registered trademarks of Microsoft Corporation. 3

General description The INSUM MPU (Multi Purpose Unit) includes the Auto-Restart-Relay function to automatically restart motors after a voltage interruption of the mains power supply which is sometimes necessary due to different process reasons. The MPU is part of the INSUM system and can be used together with INSUM Motor Control Unit (MCU) or as Stand-Alone-Device. The MPU is measuring the duration of the voltage dip and reacts depending on this measured time, i.e. perform an immediate automatic restart, a delayed restart or no automatic restart if the time was too long. There are two different modes of restart-function available : 1. ERM - Mode The MPU is performing the automatic restart of a motor after a voltage dip depending on the duration. Line voltage 0,2s 0,2s Trestart 0,2s Trestart Contactor K1/K2 Trestart :max. restart time Td : staggered start delay time Td 4

2. TDRM - Mode The MPU is performing the automatic restart of a motor after a voltage dip depending on the duration, but only if the input Auto-ON is activated. Line voltage AUTO-ON 1/2 0,2s 0,2s Trestart 0,2s TRmax Contactor K1/K2 Td Line voltage AUTO-ON 1/2 0,2s 0,2s Trestart Contactor K1/K2 Both functions ERM / TDRM are independend from each other. The function can be selected by a selector switch. The MPU device is supporting two motor starter types : NR-DOL/RCU (Non Reversing Direct Online Starter, RCU) Rev-DOL/RCU (Reversing Direct Online Starter, RCU) The MPU automatically detects the activated contactor and starts the motor in that rotation direction the motor was spinning before the voltage dip occurred. Additionally the MPU device has two General Purpose Inputs (GPI1/2) and two dedicated potential free relay outputs (GPO1/2). 5

Functional schematic L1 L2 L3 Un selector INSUM MPU Autom. Restart Relay function ERM Delayed Restart function TDRM Power supply 24VDC (UPS) Undervoltage Detection (Default setting:<65% Un,>90% Un) K2 K1 Restart delay time selector Contactor K1/K2 Status Monitor ERM-Mode (Auto Restart after voltage dip) MCU/ DCS Control OR Local Control M Auto-On1 ERM/TDRM Function selector TDRM-Mode (Auto Restart with interlocking) KR1 KR2 Auto-On2 General Purpose Inputs/Outputs 24VDC GPI1/2 GPO1/2 Cangeover relay contacts, potential free Parametrization Interface Signal outputs Undervoltage Staggered Start Watchdog Parametrization Software Tool 6

Features Microprocessor based Automatic Restart Relay Automatic restart function ERM-mode Automatic restart function TDRM-mode with interlocking (Auto-ON) Supports DOL/RCU and REV-DOL/RCU starter types Min. voltage dip detection time of 8ms Phase voltage measuring ratio (Phase-N) adjustable from 110V 277V AC/DC Undervoltage detection-level adjustable by software tool (default = 65% x Un) Voltage restoration level adjustable by software tool (default = 90% x Un) Max. voltage dip time for automatic restart adjustable from 1-120s Staggered start delay time adjustable from 1-1200s Double-Dip -function (2 voltage dips within 1s) supported Easy parametrization by selector switches or programming interface (PC) Two additional electrical isolated General Purpose Inputs (GPI) 24VDC and 2 dedicated General Purpose Output relays (GPO) 7

Wiring schematic Example REV-DOL/RCU L1 L2 L3 L1/2/3 N contactor control voltage U(n) k2 k1 F1 Auto Off (2) Power supply 24V DC + - (30) (28) M Local ON CCW Local Off K2 Local ON CW AutoOn1 AutoOn2 (20) K1 (6) (12) (10) (16) (14) KR CW KR CCW GPI 1 (21) (23) (19) (27) (29) (25) (13) (15) (17) (24) (1) (3) (5) Undervoltage (MR1) Staggered Start active Watchdog 24VDC GPO 1 Abbrev. (4) Feedback CW GPI 2 (26) F1 K1 K2 CW CCW (x) Mains Fuse Contactor CW Contactor CCW clockwise rotation counterclockwise rot. terminal pins K2 K1 (18) Feedback CCW (B) MPU (7) (9) (11) GPO 2 8

Terminal description Description MPU Terminals Description Output General Purpose GPO1 Relay common 1 2 Voltage Monitor In (Phase) Output General Purpose GPO1 Relay opening contact 3 4 Contactor Coil Voltage (CW = K1) = Feedback CW Output General Purpose GPO1 Relay closing contact Output General Purpose GPO2 Relay common Output General Purpose GPO2 Relay opening contact Output General Purpose GPO2 Relay closing contact 5 6 Auto ON 1 7 B Voltage Monitor Neutral 9 10 Contactor Control Relay Output (CW) 11 12 Contactor Control Relay Output (CW) Output "Watchdog" Relay common Output "Watchdog" Relay opening contact Output "Watchdog" Relay closing contact 13 14 15 16 17 18 Contactor Control Relay Output (CCW) Contactor Control Relay Output (CCW) Contactor Coil Voltage (CCW = K2) = Feedback CCW Signal Output "Undervoltage" (MR1) Relay closing contact Signal Output "Undervoltage" (MR1) Relay common 19 20 Auto ON 2 21 22 NC Signal Output "Undervoltage" (MR1) Relay opening contact Signal Output "Staggered Start active" Relay closing contact 23 24 25 26 General Purpose Input GPI 1 (24VDC) General Purpose Input GPI 2 (24VDC) Signal Output "Staggered Start active" Relay common Signal Output "Staggered Start active" Relay opening contact 27 28 Power Supply -24V DC 29 30 Power Supply +24V DC 9

Indication LEDs and Selector switches Programming Interface ERM/TDRM Mode Indication LEDs Nominal Voltage Un Stag.Start Delay time Nominal Voltage Un Staggered Start Delay Time Switch Pos. Voltage (Ph-N) Switch Pos. delay time 1 110V 1 1s 2 220V 2 2s 3 230V 3 5s 4 240V 4 10s 5 255V 5 15s 6 270V 6 20s 7-9 reserved 7 25s 8 30s 9 35s A B C D E 40s 45s 50s 55s 60s F 1-120s (setting via software) 10

Technical Details and Dimensions General electrical data Auxiliary supply voltage Rated operational voltage (Ue) Voltage operation range / current Current consumption MPU 24VDC +20... +36VDC 80mA (typ.) / 24VDC Max. ratings for contactor control relay KR CW / KR CCW and Watchdog / GPO1 / GPO2 relais (change over contacts) Max. switching voltage Max. switching current Max. continuous current Max. switching capacity 380V AC 8A AC 2A (DC-13) or 2A (AC-15) 2000 VA Feedback signals CW,CCW Number of analog input 2 Max. input voltage 300V General Purpose Input signals GPI1/2 Rated input voltage Input current, max. 24V DC 10 ma Digital relay output Undervoltage, Staggered Start (change over contacts) Number of digital output 2 Rated operational current 0,5A Rated operational voltage 24VDC / 230VAC Voltage measurement Phase-N (= Phase-Phase) Un selector switch pos. 110V AC/DC (=190V AC) 1 220V AC/DC (=380V AC) 2 230V AC/DC (=400V AC) 3 240V AC/DC (=415V AC) 4 255V AC/DC (=440V AC) 5 277V AC/DC (=480V AC) 6 Environmental and mechanical data Mounting on DIN rail (EN 50022-35) or with 4 screws M3 Dimensions (W x H x D) 110 x 105 x 65 mm (W x H x D) Net weight 400g Degree of protection IP20 Storage temperature range -25 +85 o C Operating temperature range -5 +55 o C Approvals CE 11

Restart Function data Undervoltage Detection Level (UDL) Voltage Restoration Level (VRL) Permissible residual coil voltage at : switched-off contactor K1 / K2, Auto-On1/2 switched-on contactor K1 / K2, Auto-On1/2 Min. detectable duration of voltage level Fast restart delay time Max. duration of voltage dip for delayed restart (Trestart) Duration of restart puls (relay KR CW/CCW) 0..99% x Un via software setting default setting: 65% x Un 0..100% x Un via software setting default setting : 90% x Un < 0,3 x Un > 0,6 x Un 8 ms 30ms Selectable by software : Range: 1s 120s Steps: 1s Default: 4s 1s Staggered start delay time (U > mains voltage return level VRL,e.g. 90%) Time selector switch pos. 1s 1 2s 2 5s 3 10s 4 15s 5 20s 6 25s 7 30s 8 35s 9 40s A 45s B 50s C 55s D 60s E software settings F (Auto) Ordering data INSUM MPU Kit Order code 1TGL 920000R2001 Incl. MPU Main Unit and MPU Baseplate INSUM MPU Baseplate kit Order code 1TGL920000R3001 Incl. MPU Cover and MPU Baseplate MPU Main Unit Order code 1TGL920000R0001 MPU Download cable Order code 1TGL920000R5001 For Parametrization Further documentation INSUM MPU User s Guide INSUM MPU Installation Sheet English/Chinese 1TGC 901011M0205 1TGC 901013M2901 12

ABB Schaltanlagentechnik GmbH Wallstadter Str. 59 D - 68526 Ladenburg / Germany Editor: DEAST/TB Publication No: 1TGC901013M0206 Related Products, News, Local Contacts: www.abb.com/mns