PK543A Amplifier Installation Instructions and Wiring used with Tek-ENTRY Apartment Entrance Panels



Similar documents
4000 Series audio door entry system (using power supply) Installation Instructions IN9307.1

SECTION PLANT INTERCOMMUNICATION SYSTEM. City of San Diego, CWP Guidelines

General Information. Installation Wiring Practices for Vickers Electronic Products

Monitors. Platea Monitor

PS 29M DUAL CHANNEL BELTPACK IN METAL CASE

Fire Fighter Phone System Installation Instructions

PagePac PAGEPAL V

Operation and Installation Manual

SECTION 3A (Rev.F) SECTION CONTENTS. Download from Technical Manuals area. sec.3a INSTALLATION...9 TECHNICAL SPECIFICATIONS...

1.1 The Audio Entry Phone System shall be suitable for 2 way voice communication between the different apartments and the main entrance panel.

2 WIRE video door entry system

LINE POWERED ADA TELEPHONE USER S MANUAL Use With Part Numbers , , , , , and

AT&T. PARTNER Plus Door Phone. Installation and Operation Manual

AUDIO VIDEO INTERCOM SYSTEMS SECURITY & SAFETY AT YOUR FINGER TIPS AUDIO VIDEO INTERCOM SYSTEMS

Active Speaker System LX523 AUDAC PROFESSIONAL AUDIO EQUIPMENT. Active Speaker System with remote input LX523. User Manual & Installation Guide

D45. SySTEm. ThE high-performance

VALCOM HANDSFREE TALKBACK PAGING SYSTEM DESIGN/INFORMATION

ADA COMPLIANT BOX STYLE TELEPHONE INSTALLATION, PROGRAMMING AND OPERATING INSTRUCTIONS FOR MODEL PBX

Instructions - THP-700RTS Telephone Headset Radio Transfer Switch with Dry Switch Closure Output

PCM2000 Configuration Guide

************* OWNER'S MANUAL BAMF800/2 BAMF1250/2 BAMF1800/2 BAMF2200/2 BAMF2600/2 BAMF1200/4 BAMF1600/4 BAMF2000/1D BAMF4000/1D BAMF5500/1D

CSP Combined Series. Telephone Door Entry. with. Proximity Keyfob Access

MGL Avionics CAN bus interface for Trig Avionics TT21/TT22 transponders

Short Range Wireless Switch System Handheld 8 Installation and Operations Guide

INSTALLATION INSTRUCTIONS

TOA INTERCOM SYSTEM. TOA Corporation OPERATING INSTRUCTIONS

G.A.L. HANDS FREE EMERGENCY TELEPHONE MODEL GAL-6400

Innovative DOOR STATION Solutions

Atkinson Dynamics Intercoms Models AD-26, AD-27, AD-56, and AD-57. Installation and Service Instructions

INSTRUCTIONS FOR URMET DOMUS DEVICE INTERCHANGEABILITY

FIREDEX Conventional Fire Panels

RADIO-INTERCOM SYSTEM

Installation Instructions

TELIKOU Intercom System. TM-200 Main Station. Instruction Manual

Digital Keypad Use s Manual

EVID Compact Sound Speaker System

Tek-ENTRY Telephone Entry System

TAC1 Telephone Entry System Installation and Programming Manual

INSTALLATION MANUAL VEHICLE SECURITY SYSTEM CE-SS200

Mounting and operating instructions. Surface-mounted hands-free feature home station

Local supplier shall be ISO 9001 & OHSAS Certified Company.

Bathroom Cabinet. Installation & User Guide. Illuminated Mirrors.

TS510 & TS500. Installation & User Guide. Compatible Equipment

VARIO PROX CARD READER INSTALLATION MANUAL

PS 155 WIRELESS INTERCOM USER MANUAL

Digital Adapter Easy Setup Guide

SPEAKER SELECTION SYSTEM

Installation & Operation Manual HANDS-FREE BLUETOOTH MEDIA INTEGRATION KIT. Perfect for ANDROID TM

SSW-iLM Keypad. Wire Harness Configuration. Note: This product is designed to be installed and serviced by security and lock industry professionals

User Manual. For additional help please send a detailed to Support@phnxaudio.com. - 1 Phoenix Audio Technologies

Smarthome SELECT Bluetooth Wireless Stereo Audio Receiver and Amplifier INTRODUCTION

School System Questionnaire

VOIP-500 Series Phone Quick Installation Guide

DSB-100 Portable Premium Bluetooth Speaker Owner s Manual

Automatic Transfer Switch FT-10 Network Control Communications Module (CCM-T) Kit

PUSH BUTTON START INSTALLATION MANUAL

Owner s Manual AWM910 JENSEN AWM910 COMPACT DISC PLAYER RADIO CD COMPACT MUSIC SYSTEM MUTE AUX BAND AUX IN PUSH PUSH PWR VOL ALARM T/F AUD SPK A SPK B

INSTALLATION AND OPERATING INSTRUCTIONS For Model GL1 Gate Locks

MAC-821SC-E. Centralized On-Off Remote Controller INSTALLATIONSMANUAL INSTALLATIONSMANUAL. English. Deutsch. Français. Nederlands. Español.

System Manual 1+n technology Issue 2013

SCREENLOGIC INTERFACE WIRELESS CONNECTION KIT

EVC40 EMERGENCY VOICE COMMUNICATION SYSTEM

Tactical Radio Adapter

CAT 885 Troubleshooting Guide

Model 201 Wiegand Touchpad Reader Installation Guide

Fire Alarm System Plans Submittal Guidelines For New and Existing Systems

Technical Guide for Installation and Maintenance

CX Zoner Installation & User Guide

USER MANUAL. KIT VIDEO DOOR PHONE 2 smart 1 family

Contact Center CC-165 INSTALLATION & USER'S GUIDE

LDG SLS-2 Two-Port RJ45 Switch

Multi Function, User Configurable Remote Vehicle Security System with 4 Button Replaceable Membrane Remote Transmitter

IEI 232e Standalone TM Keypad Installation/ Programming Manual

Video Kits. For Villas. Rock vandal resistant panel

Brio-Rmanual:Cursamanual.qxd 08/04/ :25 Page1

Setting Up the Cisco Unified IP Phone

MODEL 2202IQ (1991-MSRP $549.00)

Blue Point Engineering

TELIKOU Intercom System. MS-500(4+1 channel) Main Station Instruction Manual

V-2901 UNIVERSAL DOOR ANSWERING SYSTEM

LOXONE 12 Channel Amplifier

ANTI-THEFT SYSTEM Volvo 850 DESCRIPTION & OPERATION BASIC ALARM ACCESSORIES & EQUIPMENT Volvo Anti-Theft Systems

WIRELESS READER INTERFACE - INDOOR

USB Dual Handset Adapter for Nortel 1100-Series IP Phones

GROUPTALK FOR ANDROID VERSION for Android

PagePac Door Phone Controller V Installation and Operation Manual

bba - Balboa Bluetooth Audio (AMP) Installation & User Guide

Miniature High-Resolution Registration Mark Sensor White LED AUTOSET Remote Setup Option

SP1790JK 900MHz Wireless Indoor/Outdoor Speakers. User Manual INTRODUCTION FEATURES IMPORTANT SAFETY INFORMATION

IPX AUTOMATIC IP NETWORK LOSS BACKUP A/B SWITCH INSTRUCTION BOOK IB

PART 8: FIELD WIRING. n WARNING NOTICE. Boiler Manual

Applied Electronics. Commercial Dimming System UPDATE NOTICE

User guide. MD PBX Light MD MD PBX Light AV MD PBX Light ES MD PBX Light BG

Dialog 4220 Lite/Dialog 4222 Office

AARC-EVAC Portable Hand Held or Fixed Transmitter with SOS assist - ATX43E25 SAFETY ALERT SYSTEMS

Contents Contents Contents Overview Charging your headset Wearing the headset Powering on the headset Connecting your headset for dictation

Personal Assistance System Owner's Guide

Fax. Frequently Asked Questions (FAQ)

CAUTION! THE 7I29 USES VOLTAGE AND POWER LEVELS THAT REPRESENT A HAZARD TO LIFE AND LIMB.

Transcription:

4 mplifier Installation Instructions and Wiring used with Tek-NTRY partment ntrance anels IL86 Section Rev. - 0/009 LITION The Tek-NTRY partment ntry Intercoms provide twoway communications between the building entrance and each suite. Hands-free loudspeaker operation at the entrance panel and push button controlled communication at the suite locations provide for easy operation. ontrolled door entry is permitted by push button operation at the suite in conjunction with electric door release. Optional equipment is available to provide additional functionality, such as post office key door release, additional entrance panels, strobe light call indication (LI404B) and auxiliary relay (RY04B) for ancillary device operation (bells, lights, etc.). ROUR. Read installation instructions to determine equipment location and installation methods.. Install housings (or back boxes) and wiring.. heck wiring, connect and install equipment. 4. pply power and check operation. QUIMNT LOTION Suite Stations Locate suite stations (also known as remote stations) where convenient for use. Install a housing or back box at the desired location. ntrance anel Use an OH90 series housing and OF90 series frame for flush wall mounting. Use an OF90S series frame for surface mounting. Locate the entrance panel where it is sheltered from weather. mplifier Install the amplifier inside the entrance panel when using an OH90 series housing. The amplifier must be installed outside the entrance panel when using an OF90S series surface frame. Refer to onnections Section, Item # for further details. WIRIN Suite Stations Stations may be connected in risers using the following cable configurations: -wire stations: twisted pair # W, plus conductor # W per station in riser. 4-wire stations: twisted pair # W, plus conductor #W, plus conductor # W per station in riser. -wire stations: twisted pair # W, plus conductor # W, plus conductor # W per station in riser. The maximum cable length is 400 feet (0 meters). dditional risers may be added as needed. Station cables must not be run in the same conduit with (or too close to) electrical wiring or background music, and must not be close to fluorescent lighting or other electrical equipment. Failing to observe this requirement can result in noise entering the intercom audio. nsure that sufficient amounts of cable are left in the back box to make connections to stations. Transformer able wiring must be conductor #8 W with a maximum cable length of 80 feet ( meters). If using #4 W wire, this distance can be extended to 00 feet (60 meters). Route cable away from suite station wiring and maintain a minimum of feet ( meter) of clearance between the transformer and the amplifier. oor Release able wiring must be conductor #8 W with a maximum length of 0 feet ( meters). See Figure 4 oorstrike pplications for specifics of each door control unit configuration. Note: n SS06 transformer must be used for 4 V doorstrike and V Maglock applications (8 volt tap required). opyright TekTone Sound & Signal Mfg., Inc. ll Rights Reserved. LH OMMUNITIONS 4 entral rive Farmingdale, NY 7-0 Toll-Free Technical Line: -800-666-4800 hone: (6) 777-00 Fax: (6) 777-99 Website: www.lphaommunications.com mail: info@alphacommunications.com

ONNTIONS Before connecting to unit and applying power, verify that wires are free from shorts and grounds. Make connections as per Figure 4 Wiring iagram. Observe the following notes:. o not apply power to the transformer primary until the entire system has been installed and checked for shorts and grounds. The common wires connecting to terminals,,, and must show open circuit when tested with an ohmmeter.. Use twisted pair wiring as shown. o not interchange wires or reverse polarity.. Install 4 amplifier inside the entrance panel when using OH90 series housing. If it is necessary to install the amplifier elsewhere due to temperature extremes (operating temperature range is 0 0 ) or because the entrance panel is not large enough to house the amplifier, then use a conductor shielded cable for the entrance panel speaker (connect shield drain to amplifier terminal ). 4. The amplifier must be located at least feet ( meter) from the transformer or other electrical devices.. o not run wiring for station common wires and entrance panel speaker in the same cable and/or conduit. This will cause feedback on the system. 6. oor release wiring should be run separate from entrance panel speaker wiring. SHUNT N ISWITH STTINS Set the dipswitches on the 4 as per application requirements. See also Figure 4 Shunts and Settings. The selectable features and controls are as follows: Shunt J Shunt J Shunt J Short oor Time Medium oor Time Long oor Time ntrance Tone Install for maglock applications. Maximum current for maglock is 00 m at V, or 0 m at 4 V. lace shunt across: for doorstrike applications; for maglock applications lace shunt across: for + V maglock; for +4 V maglock or / doorstrike applications Set SW to ON (right) and SW to OFF (left), seconds Set SW to OFF (left) and SW to ON (right), 0 seconds Set SW to OFF (left) and SW to OFF (left), seconds Set SW to ON (right) to activate this feature must use warble tone ostal Timer 4 ompatible oor Hold Time Out Talk Interlock Set SW4 to ON (right) and SW to OFF (left) to make postal control timer independent at seconds Set SW4 to OFF (left) and SW to ON (right) for 4 drop-in replacement* Set SW6 to OFF (left) to activate this feature Set SW7 to OFF (left) to activate this feature (available for 4-wire stations only) * For 4 ompatible mode, set SW4 OFF, SW ON, SW6 ON & SW7 ON. lso remove J shunt, set J to shunt and set J shunt to. The ntrance Tone setting, when active, will generate a user feedback tone at the entrance panel when users press call buttons. If the warble tone is in use and the entrance tone feature is active, the tone will also be heard through the entrance panel speaker when the call button is pressed. The oor Hold Time Out setting, when active, will allow the door control device (doorstrike, maglock, etc.) to time out normally, despite the OOR button being held at the suite. The Talk Interlock setting, when active, will require that the TL button (at the suite) is pressed before the OOR button will activate the door control device. OTIONL SSORIS Install optional accessories according to the instructions provided. FINISH & TST INSTLLTION. onfirm that all equipment is properly installed.. onnect power to transformer primary (0 V), and ensure that local electrical codes have been complied with.. t the entrance panel, push each button and verify that the correct suite is called. 4. t each suite, push the TL and LISTN buttons to communicate with a person at the entrance panel. Then push the OOR button to confirm that the door release operates correctly. JUSTMNTS Voice Volume and Tone Volume can be adjusted on the amplifier, via the access hole, with a small screwdriver. age IL86 4 Installation Instructions opyright TekTone Sound & Signal Mfg., Inc. ll Rights Reserved.

TROUBLSHOOTIN (refer to theory drawing for additional information) ntire System ead If power L is not illuminated, check for 6 V at transformer secondary and 0 V at transformer primary. If L is illuminated, review field wiring and perform direct test using one of the apartment stations to eliminate field wiring. No Talk heck wiring to terminals and, and check whether wiring to entrance panel speaker is shorted or open. Suite station can be swap tested with another working unit. No Listen heck wiring to terminals and, or for short between terminals and. heck to see if wiring to entrance panel speaker is shorted or open. Suite station can be swap tested with another working unit. No oor Operation heck wiring to door release for shorts and opens, or for defective door release. onfirm that shunts are properly set for door release type and that connections to appropriate output have been made. heck wiring to terminals and, or and (depending upon suite station type). No all Tone heck wiring to terminal or to entrance panel, related entrance panel call buttons, and suite station X terminal. Suite station can be swap tested with another working unit. xcessive Hum or istortion heck whether wiring is installed too close to electrical wiring or electrical devices; amplifier installed too close to transformers or other electrical devices; twisted pair wiring not used as required; or amplifier voice volume set too high. Radio Interference onnect terminal from amplifier to electrical ground. Note: This connection is not shown on the wiring diagram, since the situation is not always improved by adding it. If the problem persists, consult the factory or service representative. Oscillation(feedback or howling) Reduce the voice volume until oscillation is eliminated. If oscillation stops when the call tone wire is removed from, set entrance tone (SW) to the OFF (left) position. SINL FLOW N THORY OF ORTION FOR 4 MLIFIR N RTMNT INTROM SYSTM The following example describes an apartment intercom system using a 4 in conjunction with a 4-wire suite station. Refer also to Figure 4 4 Theory iagram. all Button ressing a suite station call button on the entrance panel routes the call tone from the or terminal on the 4 to the X terminal (tone in) on the associated suite station. This signal then passes through the speaker and returns to the 4 via the terminal (audio common). If the warble tone is in use and the entrance tone feature is active, the tone will also be heard through the entrance panel speaker when the call button is pressed. Talk Button ressing the TL button at a suite station connects the suite station s internal speaker to terminals and of the 4, which serves as an audio input to the amplifier. The audio is then amplified and sent to terminals and, which are connected to the entrance panel s speaker (speaker mode). Listen Button ressing the LISTN button at a suite station connects the suite station s internal speaker to terminals and of the 4, which serves as an audio output from the amplifier. This allows the suite station to receive the amplified audio being received by the amplifier on terminals and from the entrance panel speaker (microphone mode). oor Button ressing the OOR button at a suite station creates a closure between terminals and on the 4. This state is sensed by the amplifier and causes the door release to be activated (output specifics are based on 4 settings). This state is also triggered by shorting terminals and as is typically done by a postal lock. opyright TekTone Sound & Signal Mfg., Inc. ll Rights Reserved. IL86 4 Installation Instructions age

Figure 4 Wiring iagram NTRY NL Wire Intercom Station partment all Buttons YL YL/BL R OR /BL OR/BL BL RN RY R/ / 4 mplifier udio from station X 4 Wire Intercom Station X Wire Intercom Station Switched udio Wire sta. door release udio from station (Optional) IR40 onnections Blue Wire to Violet Wire to ray Wire to White -- X (call wire) O NOT run these wires in the same cable! It will cause feedback. If shielded wire is used, connect shields to orange/black wire () at amplifier. Twisted air Twisted air See note #4 X Twisted air Notes: Twisted air. Use # W wire unless shown otherwise.. Warble or Steady Tone is hard wire selectable.. If entry panel has handset, connect it in place of speaker. 4., 4 and wire intercom station types may be used in any combination, with the exception of the IR0, which can only be used in conjunction with other IR0B or devices.. oor release wiring should be run separate from entrance panel speaker wiring. 6. Shunts referred to in diagrams are located on 4. 7. Terminal is for strobe only, do NOT connect other wires to this terminal. ost Office Lock dapter rawing Name & Number: IL86 4 Wiring Rev 004 6 V #8 W Wire SS0 TRNSFORMR ONNT TO 0 V 6V oorstrike onfiguration Remove shunt on J, set J shunt to and and J shunt to and. (see other diagrams for additional configurations) (-) oor power (+) oor power Switched door release Input (ommon) Input Strobe (LI404) power (+4V) ntry speaker common ntry speaker switched audio Wire station door release wire station audio udio from station age 4 IL86 4 Installation Instructions opyright TekTone Sound & Signal Mfg., Inc. ll Rights Reserved.

Figure 4 oorstrike pplications +4V oorstrike pplication: Remove J Shunt Set J shunt to and Set J shunt to and #8 W Wire 6V oorstrike pplication: Remove J Shunt Set J shunt to and Set J shunt to and #8 W Wire oorstrike YL YL/BL R OR /BL OR/BL BL RN RY R/ / 4 mplifier (-) oor power (+) oor power Switched door release Input (ommon) Input Strobe (LI404) power (+4V) ntry speaker common ntry speaker switched audio Wire station door release wire station audio udio from station oorstrike YL YL/BL R OR /BL OR/BL BL RN RY R/ / 4 mplifier (-) oor power (+) oor power Switched door release Input (ommon) Input Strobe (LI404) power (+4V) ntry speaker common ntry speaker switched audio Wire station door release wire station audio udio from station 6 V Tap ommon 8 V Tap ONNT TO 0 V 6 V ONNT TO 0 V SS06 TRNSFORMR #8 W Wire #8 W Wire SS0 TRNSFORMR rawing Name & Number: IL86 4 oorstrike pplications Rev0 00604 Maglock #8 W Wire +V/00m Maglock pplication: Install J Shunt Set J shunt to and Set J shunt to and #8 W Wire +4V/0m Maglock pplication: Install J Shunt Set J shunt to and Set J shunt to and 4 pin header J, located in front of main connector. L 8 4 mplifier YL (-) oor power YL/BL (+) oor power Switched door release R Input (ommon) OR Input /BL Strobe (LI404) power (+4V) OR/BL ntry speaker common BL ntry speaker switched audio Wire station door release RN wire station audio RY udio from station R/ / Maglock YL YL/BL R OR /BL OR/BL BL RN RY R/ / 4 mplifier (-) oor power (+) oor power Switched door release Input (ommon) Input Strobe (LI404) power (+4V) ntry speaker common ntry speaker switched audio Wire station door release wire station audio udio from station 6 V Tap ommon 8 V Tap ONNT TO 0 V 6 V ONNT TO 0 V SS06 TRNSFORMR #8 W Wire #8 W Wire SS0 TRNSFORMR Note: L and 8 are each available on two pins of the J connector. Brackets are provided to identify. rawing Name & Number: IL86 4 oorstrike pplications Rev 0606 opyright TekTone Sound & Signal Mfg., Inc. ll Rights Reserved. IL86 4 Installation Instructions age

Figure 4 Shunts and Settings J ONNTORS L 8 4 OWR J ower L J L & 8 onnector Main onnector 0B Interface onnector ipswitch N OFF = LON OOR TIM TON VOLUM L = OWR J J J L- OOR L+ OOR +4V - OOR STRI - MLO - +V OUT - +4V OUT TRNSFORMR SR.O. LO (4) OMMON WIRS BU BU S MNUL FOR TILS SWITH FUNTIONS SHORT OOR TIM MIUM OOR TIM NTRN TON 4 OSTL TIMR 4 OMTIBL 6 OOR HOL TIMOUT 7 TL INTRLO VOI VOLUM WRNIN VRIFY LL ONNTIONS BFOR TTHIN TRNSFORMR For 4 drop-in replacement set: SW4 OFF, SW ON, SW6 ON & SW7 ON Shunts: J remove, J - & J - 4 Wire Intercom Station udio from station X RY04B B X ipswitch Settings: (right and left are referenced from the view above) Short oor Time - set SW to ON (right) and SW to OFF (left), seconds Medium oor Time - set SW to OFF (left) and SW to ON (right), 0 seconds Long oor Time - set SW to OFF (left) and SW to OFF (left), seconds ntrance Tone - set SW to ON (right) to activate this feature ostal Timer - set SW4 to ON (right) and SW to OFF (left) to make postal control timer independent at seconds 4 ompatible - set SW4 to OFF (left) and SW to ON (right) to make unit for drop-in replacement for 4* oor Hold Time Out - set SW6 to OFF (left) to activate this feature Talk Interlock - set SW7 to OFF (left) to activate this feature (available for 4-wire stations only) * - For 4 ompatible mode, set SW4 OFF, SW ON, SW6 ON & SW7 ON. lso remove J shunt, set J to shunt - and set J shunt to -. rawing Name & Number: IL86 4 Shunts and Settings RY04B Wiring Rev 006 age 6 IL86 4 Installation Instructions opyright TekTone Sound & Signal Mfg., Inc. ll Rights Reserved.

Figure 4 Theory iagram xample of internal connections of 4 Wire Intercom Station (most common station) NTRY NL 6 V ONNT TO 0 V Talk SS0 TRNSFORMR oor Listen partment all Buttons YL YL/BL R OR /BL OR/BL BL RN RY R/ / 6V oorstrike onfiguration 4 mplifier udio from station X (-) oor power (+) oor power Switched door release Input (ommon) Input Strobe (LI404) power (+4V) ntry speaker common ntry speaker switched audio Wire station door release wire station audio udio from station ost Office Lock dapter rawing Name & Number: IL86 4 Theory Rev0 00704 opyright TekTone Sound & Signal Mfg., Inc. ll Rights Reserved. IL86 4 Installation Instructions age 7