Operating Manual EDS3090. Portable insulation fault location system for energised and deenergised systems Software version: D316 V1.



Similar documents
ISOMETER IRDH275. Insulation monitoring device for unearthed AC, AC/DC and DC systems (IT systems) Vorläufiges Datenblatt

Product Information Sheet UH28CS-12kV Hi Pot Tester

Product Information Sheet UH36 Hi Pot Tester

Operating Manual A-ISOMETER IR1575PG1

ELR: ABB range of front panel residual current relays Protection device according to IEC/EN Annex M

Modular I/O System Analog and Digital Interface Modules

Insulation resistance

LINETRAXX VMD460-NA. Network and system protection (NS protection) for monitoring the power feed-in of power generation systems

CONTINUOUS MONITORING AND AVOIDANCE OF RESIDUAL CURRENTS IN DATA CENTRES WITH RCM White paper Revision 2

UM-X Field display for continous level sensors

ESP 120 M1, ESP 208 M1, ESP 240 M1, ESP 415 M1, ESP 277 M1, ESP 480 M1 and M1R variants. Installation instructions ESP M1/M1R mains protectors

Quick Connect. quick - simple - efficient.

Auto-ranging Digital Multimeter INSTRUCTION MANUAL

Current Probes. User Manual

IDEAL INDUSTRIES, INC. TECHNICAL MANUAL MODELS:

Instruction Manual for Operating Panel 301 and 302

Achat 115MA full-range speaker. user manual

GSM HOME SECURITY SYSTEM

Ground Resistance Clamp On Tester

Current Monitoring Kit

Technical data. General specifications. Indicators/operating means. 30 Hz Multiplex operation 30 Hz / n, n = number of sensors, n 5

Physical Specifications (Custom design available.)

MOUNTING AND OPERATING INSTRUCTIONS

Transformerless UPS systems and the 9900 By: John Steele, EIT Engineering Manager

DUAL%CHANNEL BROADBAND%LINEAR%AMPLIFIER Model&A800D

SMARTY 160 POWER page 4-5 SMARTY 180 / 220 XL page 4-6 SMARTY TX 250 page 4-7. SMARTY TX 160 Alu page 4-8 SMARTY TX 220 Alu page 4-9

Technical Description. Transistor D.C. Chopper Controller Type GS 24 S

Operating Manual for the Electronic Built-in Interval Timer. Micro II (Countdown Timer)

Inductive Sensors Single or Dual Loop Detectors Type LD with teach-in

Operating instructions Diffuse reflection sensor with background suppression O1D101 O1D / / 2012

DRTS 33. The new generation of advanced test equipments for Relays, Energy meters, Transducers and Power quality meters

User s Manual Before using the inverter, you need to read and save the safety instructions.

FAQ s on Siemens Magmeters

Product and functional description

FL ballasts Electronic dimming. PCA T5 BASIC lp Y II, W BASIC T5

Hand-held thermometer Model CTH7000

Installation instructions for mains wire-in protectors ESP D1, D1R, D1/LCD and D1R/LCD variants

magnetronic GmbH Kreuzhofstr München Tel.: 089/ Fax: 089/ Battery control system DCC 6000

Technical data UNIBLOCK UBSF

Type SA-1 Generator Differential Relay

Technical data. General specifications. Indicators/operating means. Electrical specifications Operating voltage U B Power consumption P 0 Interface

Agilent U1610/20A Handheld Digital Oscilloscope Quick Start Guide

OPERATION MANUAL VALVE CHECKER G

AutoRanging Digital MultiMeter

Operating instructions. AS-i Profibus gateway AC1411 / AC /00 04/2014

Transistor Amplifiers

Electronic Pressure Switch EDS 300

EVC40 EMERGENCY VOICE COMMUNICATION SYSTEM

3M Wrist Strap and Footwear Tester 740. User s Guide

Drayton Digistat +2RF/+3RF

instabus KNX / EIB System System E F G H

SITRANS F M MAGFLO. Electromagnetic flowmeters Signal converter types MAG 5000, MAG Manual *083R9141* Order no.

Type: EASY719 DC RC Article No.: Ordering information Relay outputs Quantity 6 Power supply V DC 24 V DC. Description

TECHNICAL DATASHEET #TD1404AX PWM CONTROLLED SOLENOID DRIVER

ABB Drives. User s Manual HTL Encoder Interface FEN-31

Current Monitoring Kit QUICK START GUIDE

Handheld portable appliance testers

SPY-BATT Battery Tutor Device Installation Manual Rev /04/2016

RC Circuits and The Oscilloscope Physics Lab X

UCI274C - Technical Data Sheet

Manual Ranging MultiMeter

UCI274H - Technical Data Sheet

ABB 1 NEW. Three-phase monitoring relay for grid feeding CM-UFS.1. Data sheet. Features. Approvals. Marks. Order data. Order data - Accessories

Positive-guided relay outputs: 3 safety contacts (N/O), instantaneous. 1 auxiliary contact (N/C), instantaneous

Model UT201/202: OPERATING MANUAL. Table of Contents

12 SOLAR PHOTOVOLTAIC POWER SUPPLY SYSTEMS by John Ware. PV modules are current-limiting

INSTRUCTIONS FOR USE Pro-Ject Phono Box II USB

Electronic timer CT-AHD.12 OFF-delayed with 1 c/o (SPDT) contact

38 SERIES. Relay interface modules A. EMR Electromechanical Relays. Common features. SSR Solid State Relays. 6.

EMOSAFE EN-100. Network Isolators for PCB assembly 1 GENERAL DESCRIPTION. Product Data Sheet ENGLISH

Manual ISOMETER IRDH575

Voltage Regulator SPAU 341 C. Product Guide

USER MANUAL CHARGING STATIONS FOR ELECTRIC VEHICLES

Fluke 1650B Series Multifunction Installation Testers

Power Supply and Indicator Unit Type Fig. 1 Type Mounting and Operating Instructions EB 9539 EN

Charge Controller CC611/CC612 Preliminary datasheet

Elektromotoren und Gerätebau Barleben GmbH

ABB 1. Three-phase monitoring relay CM-PFS. Data sheet. Features. Approvals. Marks. Order data. Order data - Accessories. Application.

Mounting Instructions. Torque Transducer. A en

Electrical safety. in control and auxiliary circuits. Safety objectives

DAB+ / FM Tuner Model: TU-201

T Substation Maintenance and Commissioning Test Equipment

AUTODIALLER / QUICKDIALLER - SA132

Dielectric Withstand and Ground Bond Testers For Production Line Safety Agency Compliance Testing

User s Guide DDS-3X25 USB ARBITRARY FUNCTION GENERATOR

Features, Benefits, and Operation

INSTRUCTIONS FOR USE Pro-Ject Tube Box S

VOLTAGE/CURRENT CALIBRATOR ISO-TECH ILC-421

Daker DK 1, 2, 3 kva. Manuel d installation Installation manual. Part. LE05334AC-07/13-01 GF

J TB/TW Temperature limiter, temperature monitor

Power Supply Unit, Primary Switched, Narrow Design MINI-PS-12-24DC/24DC/1

For the electronic measurement of current: DC, AC, pulsed..., with galvanic separation between the primary and the secondary circuit.

TS510 & TS500. Installation & User Guide. Compatible Equipment

TYXIA. * _Rev.1* Installation and User Guide. Wireless receiver. TYXIA RF channel

Electrical safety requirements in DC distribution systems

Automotive Sensor Simulator. Automotive sensor simulator. Operating manual. AutoSim

SVPRIBOR ALFA DSL. Users Manual

SELECTION, APPLICATION AND MAINTENANCE

SKR - industry relay

LOXONE 12 Channel Amplifier

Transcription:

Operating Manual EDS3090 Portable insulation fault location system for energised and deenergised systems Software version: D316 V1.0 TGH1420en/12.2011

Dipl.-Ing. W. Bender GmbH & Co. KG Londorfer Str. 65 35305 Grünberg Germany Postfach 1161 35301 Grünberg Germany Tel.: +49 6401 807-0 Fax: +49 6401 807-259 E-mail: info@bender-de.com Web: http://www.bender-de.com Dipl.-Ing. W. Bender GmbH & Co. KG All rights reserved. Reprinting only with permission of the publisher. Subject to change!

Table of Contents 1. How to use this operating manual effectively... 7 1.1 How to use this manual... 7 1.2 Explanations of symbols and notes... 7 1.3 Chapters at a glance... 8 2. Safety instructions... 9 2.1 Intended use... 9 2.2 Device-specific safety instructions... 9 2.3 General safety instructions... 9 2.4 Skilled persons... 10 3. System description... 11 3.1 System components... 11 3.1.1 Overview system components... 11 3.1.2 List of insulation fault location system types... 12 3.1.3 Accessories... 13 3.2 Function of the system components... 14 3.2.1 PGH18... insulation fault test device... 14 3.2.2 Insulation fault evaluator EDS190P... 14 3.2.3 Measuring clamps... 14 3.2.4 Coupling device AGE185... 15 3.3 Operating principle of insulation fault location (IΔs)... 15 3.3.1 Block diagram EDS system... 16 3.3.2 Test cycle... 16 3.3.3 Terms... 17 3.3.4 Currents in the EDS system... 17 3.4 Operating principle of residual current measurement (IΔn)... 18 4. Points to be considered before use... 19 4.1 How does an insulation fault location system work?... 19 4.2 Requirements for reliable insulation fault location... 20 4.3 Reduced test current... 22 4.4 Characteristic curves on the response sensitivity of EDS190P... 22 4.4.1 Response characteristic curves for main circuits in 3AC systems... 23 TGH1420en/12.2011 3

Table of Contents 4.4.2 Response characteristic curves for main circuits in AC systems... 24 4.4.3 Response characteristic curves for main circuits in DC systems... 24 4.4.4 Response characteristic curves for control circuits in AC systems... 25 4.4.5 Response characteristic curves for control circuits in DC systems... 25 5. Commissioning and connection... 27 5.1 Decoupling the insulation monitoring device... 27 5.2 Deenergised systems... 27 5.3 Connection to an IT system... 28 6. Operation... 29 6.1 Brief description of insulation fault location (EDS mode)... 29 6.1.1 Commissioning of the PGH18... for test current supply... 29 6.1.2 Insulation fault location with EDS190P... 29 6.2 Operating elements of the PGH18...... 30 6.3 Display and operating elements of the EDS190P... 31 6.4 Operation of the EDS190P... 33 6.4.1 Switching the device on and off... 33 6.4.2 Display illumination provides improved readability... 33 6.4.3 Switching between the operating modes insulation fault location IΔs and residual current measurement IΔn... 33 6.4.4 Display elements and their meaning... 34 6.5 Standard displays of the EDS190P... 35 6.5.1 Standard display without enclosing the cable to be measured... 35 6.5.2 Standard display in the EDS mode (IΔs) with the cable enclosed... 35 6.5.3 Standard display in the RCM mode (IΔn) with the cable enclosed... 35 6.6 Alarms in the EDS or RCM mode... 35 6.7 Indication of device and measuring errors... 36 6.8 Factory settings EDS190P (delivery condition)... 36 6.9 Menu structure... 37 6.10 Navigation within the menu... 37 6.11 Menu item: Settings / General... 38 6.12 Menu item: Settings / IΔs... 38 6.13 Menu item: Settings / IΔn... 39 6.14 Menu item: Settings / system... 39 6.15 Menu item: View harmonics (Harmonics)... 39 6.16 Practical use... 40 6.16.1 Use as a portable insulation fault location system... 40 6.16.2 Using the EDS190P within a permanently installed EDS system... 42 6.16.3 EDS309... in diode-decoupled DC systems... 44 4 TGH1420en/12.2011

Table of Contents 6.16.4 Using the EDS190P as a residual current monitor... 47 6.16.5 Measuring harmonics... 48 6.17 Coupling device AGE185 for higher voltages... 49 6.18 Power supply of the EDS190P... 50 6.18.1 Displaying the battery status... 50 6.18.2 Replacing batteries or accumulators... 50 6.18.3 Power supply unit delivered with the system... 50 7. Technical data... 51 7.1 Technical data of the EDS309... system... 51 7.2 Technical data PGH18...... 51 7.3 Technical data EDS190P... 52 7.4 Technical data measuring clamps... 53 7.5 Technical data AGE185... 53 7.6 Dimension diagrams... 54 7.7 Standards... 55 7.8 Ordering information... 56 7.9 List of components... 57 8. Frequently asked questions... 59 INDEX... 61 TGH1420en/12.2011 5

Table of Contents 6 TGH1420en/12.2011

1. How to use this operating manual effectively 1.1 How to use this manual This operating manual describes how to operate the portable insulation fault location system EDS309... (with EDS190P, software version V1.0). It is designed for skilled personnel working in electrical engineering and electronics and in particular for those designing, installing and operating electrical systems. Before using the equipment, please read this operating manual, the supplement entitled Important safety instructions for Bender Products" and the instruction leaflets supplied with the individual system components. Please keep this documentation close at hand near to the equipment. Should you have any questions, please do not hesitate to contact our technical sales team. We are also happy to provide on-site services. Please contact our Service Department for more information. Service-Hotline: 0700-BenderHelp (Telefon and Fax) Carl-Benz-Straße 10 35305 Grünberg Germany Tel: +49 6401-807-760 Fax: +49 6401-807-629 E-Mail: info@bender-service.com www.bender-de.com Although great care has been taken in the drafting of this operating manual, it may nevertheless contain error and mistakes. The Bender Group cannot accept any liability for injury to persons or damage to property resulting from errors or mistakes in this manual. 1.2 Explanations of symbols and notes The following designations and symbols are used in this documentation for hazards and warnings: Information calling attention to hazards are marked with this warning symbol. Information intended to assist the user to make optimum use of the product are marked with the Info symbol. TGH1420en/12.2011 7

How to use this operating manual effectively 1.3 Chapters at a glance 1. How to use this operating manual effectively: This chapter provides tips and useful information on how to use this manual. 2. Safety instructions This chapter describes the dangers during installation and when operating the device. 3. System description: This chapter provides an overview of the system components, a description of their function and the fundamentals of insulation fault location. The last chapter describes the function of residual current measurement. 4. Points to be considered before use: This chapter describes the practical aspects of insulation fault location and provides a number of characteristic curves for evaluation of the response values to be set. 5. Commissioning and connection: This chapter describes the connection of the EDS309... to a system to be tested. 6. Operation: This chapter provides a description of the graphical user interface of the EDS190P. In addition, you will find a representation of the menu structure and the graphical representation of various standard displays. You will also find details about the power supply of the EDS190P. 7. Technical data: In addition to the data in tabular form, you will be informed about standards and the dimensions of the system components. 8. Frequently asked questions: This chapter will help you to recognise faults quickly which are likely to occur and provides suggestions for trouble shooting. 9. INDEX: Use the index to look up keywords quickly. 8 TGH1420en/12.2011

2. Safety instructions 2.1 Intended use The EDS309... is a portable insulation fault location system designed to locate insulation faults in IT systems. All versions are also suitable for measuring residual currents in TN and TT systems. The EDS3096PG is particularly suitable for insulation fault location in de-energised systems. Please take note of the limits for the application area specified in the technical data. Use deviating from or beyond the scope of this is considered non-compliant. System interferences and excessively high system leakage capacitances may influence the accuracy of the measurement negatively. 2.2 Device-specific safety instructions If the test current of the PGH18... is too high, sensitive loads (e.g. in control circuits) may be damaged or switching operations may be activated unintentionally. Therefore, it is recommended to select a lower test current (1 resp. 10 ma). In systems with programmable controllers (PLC), only EDS3091 or EDS3091PG may be used. The test voltage of DC 50 V in the voltage source (PGH186) integrated in the insulation fault location system EDS3096PG may cause interferences on sensitive system components. In case of doubt please consult Bender. The test current of the PGH185 or PGH186 may trigger RCDs. The test current is limited to max. 25 ma (resp. 10 ma), nevertheless, 30 ma RCDs may be triggered between 15 and 30 ma. Inside the measuring clamp, you should aim for the maximum possible symmetry of the conductors. Due to an excessively high load current, the measuring clamp can reach a saturation state that may cause an alarm message IΔn >10A. If electrical interferences occur during operation, the device may trip incorrectly and may indicate incorrect values on the display. 2.3 General safety instructions In addition to this data sheet, the documentation of the device includes a sheet entitled "Important safety instructions for BENDER products. TGH1420en/12.2011 9

Safety instructions 2.4 Skilled persons Only skilled persons may work on Bender products. Skilled means, persons who are familiar with the assembly, commissioning and operation of the equipment and have undergone appropriate training. Such persons must have read this manual and understood all instructions relating to safety. 10 TGH1420en/12.2011

3. System description 3.1 System components A detailed overview of the scope of delivery is given on page 57. 3.1.1 Overview system components The main task of the EDS309... is insulation fault location in IT systems. For this purpose, the individual components of the EDS309... are used in combination. 1 2 PSA3020 ON PSA3052 100mA M Us ON 25mA 10mA Imax MESSZANGE / CLAMP ON PROBE Datenblatt / Datasheet : TGH1320 Durchmesser / Diameter : 52 mm Art.-Nr. / Art.-no. : B 980 694 max. 1 A 600 V CAT III 1000 ma / 0,1 ma ~ 3(N)AC 0...575V mit/with 500...790V DC 0...504V AGE185 400...960V L1(+) L2(-) L3 PGH186 3 4 5 1 Aluminium case with carrying strap 2 Measuring clamp PSA3020 (main circuits) or PSA3320 (control circuits) Inside diameter of the measuring clamp 20 mm 3 Insulation fault test device PGH18... to generate a test current signal for insulation fault location 4 Insulation fault evaluator EDS190P for the connection of measuring clamps and for the location of insulation faults 5 Measuring clamp PSA3052 (main circuits) or PSA3352 (control circuits) Inside diameter of the measuring clamp 52 mm TGH1420en/12.2011 11

System description 3.1.2 List of insulation fault location system types All device versions listed below are suitable for residual current measurement in TT and TN systems (earthed systems). The different system types and the measuring tasks they can be used for are listed below: Insulation fault location systems for main circuits Permissible system voltage ranges for main circuits: Insulation fault location in IT systems up to AC 42...460 Hz, 20...575 V and DC 20...504 V Insulation fault location with AGE185 up to AC 42...460 Hz 500...790 V, DC 400...960 V: EDS3090: Applicable in IT systems where a PGH471 insulation fault test device or an IRDH575 is already installed. EDS3090PG: Supply voltage of the PGH185 insulation fault test device delivered with the EDS system: AC 50...60 Hz, 230 V Applicable in IT systems where neither a PGH471 insulation fault test device nor an IRDH575 is installed. EDS3090PG-13: Supply voltage of the PGH185-13 insulation fault test device delivered with the EDS system: AC 50...60 Hz, 90 132 V Applicable in IT systems where neither a PGH471 insulation fault test device nor an IRDH575 is installed. Permissible system voltage ranges for main circuits: Insulation fault location in IT systems up to AC 42...460 Hz, 0...575 V and DC 0...504 V Insulation fault location with AGE185 up to AC 42...460 Hz 500...790 V, DC 400...960 V: EDS3096PG: Supply voltage of the PGH186 insulation fault test device delivered with the EDS system: AC 50...60 Hz, 230 V Insulation fault location, also in IT systems with all poles disconnected Applicable in IT systems where neither a PGH471 insulation fault test device nor an IRDH575 is installed. EDS3096PG-13: Supply voltage of the PGH186-13 insulation fault test device delivered with the EDS system: AC 50...60 Hz, 90 132 V Insulation fault location, also in IT systems with all poles disconnected Applicable in IT systems where neither a PGH471 insulation fault test device nor an IRDH575 is installed. 12 TGH1420en/12.2011

System description Insulation fault location systems for control circuits Permissible system voltage for control circuits: Insulation fault location in IT systems up to AC 42...460 Hz, 20...265 V and DC 20...308 V. EDS3091: Applicable in IT systems where a PGH473 insulation fault test device or an IRDH575 is already installed. EDS3091PG: Supply voltage of the PGH183 insulation fault test device delivered with the EDS system: AC 50...60 Hz, 230 V Applicable in IT systems where neither a PGH473 insulation fault test device nor an IRDH575 is installed. EDS3091PG-13: Supply voltage of the PGH183-13 insulation fault test device delivered with the EDS system: AC 50...60 Hz, 90 132 V Applicable in IT systems where neither a PGH473 insulation fault test device nor an IRDH575 is installed. Insulation fault location system for main circuits and control circuits EDS3092PG: It consists of the same components as EDS3090PG and EDS3091PG and combines the features of the two devices. 3.1.3 Accessories For details about optional accessories also refer to ordering information and the list of components on page 56 and page 57. When working with the EDS309... only use those components which are delivered with the system. In particular, do not use any other measuring clamps! This also applies to additional measuring clamps or measuring current transformers from the Bender range which are not exclusively designed for use with EDS309.... TGH1420en/12.2011 13

System description 3.2 Function of the system components 3.2.1 PGH18... insulation fault test device The PGH18... generates a defined test current signal. The test current generated in this manner depends on the size of the present insulation fault and the system voltage. Depending on the switch position of the PGH185 or PGH186 the test current is limited to a maximum of 25 ma or 10 ma respectively, the PGH183 limits the test current to a maximum of 2.5 ma or 1 ma respectively. In deenergised IT systems or in IT systems with a system voltage of < 50 V, the PGH186 drives a test current through an integrated voltage source (DC 50 V). In IT systems with a system voltage of > 50 V, the currently available in the system is used to drive the test current. 3.2.2 Insulation fault evaluator EDS190P The insulation fault evaluator EDS190P provides the following measuring functions: Insulation fault location I ΔS (EDS mode) for use in IT AC systems or DC systems: within the portable EDS309... insulation fault location system or within a permanently installed EDS46.../49... insulation fault location system. Residual current measurement I Δn (RCM mode) for use in TN or TT AC systems. The response value range is listed in the Tabelle 3.1 auf Seite 14. Response value The response value is determined by the sensitivity of the EDS190P evaluator. In DC, AC and 3AC IT systems, this is an arithmetic average value that can be set according to Tabelle 3.1 auf Seite 14. System interferences and excessively high system leakage capacitances may have a negative influence on the accuracy. 3.2.3 Measuring clamps Measuring clamps detect the test current signal resp. the residual current. The measuring lead has a length of approximately 2 m. The connection to the EDS190P is made via a BNC connector. The most important data of the different measuring clamps are listed in the table below. IT system TN/TT system Main circuit (EDS3090..., 3096...) Tab. 3.1: Measuring clamps and response values for EDS190P Control circuit (EDS3091...) Measuring clamps PSA3020, PSA3052, PSA3165 PSA3320, PSA3352 Measuring range 2...50 ma 0...5 ma Response value 2...10 ma, ±30 % / ±2 ma 0.2...1 ma, ±30 % / ±0.1 ma Measuring clamps PSA3020, PSA3052, PSA3165 PSA3320, PSA3352 Measuring range 5 ma...10 A 2 ma...2 A Response value 10 ma...10 A 5 ma...1 A If measuring current transformers are to be used instead of measuring clamps, you will need the adapter delivered with the system: BNC/4 mm plug. See table on page 57. 14 TGH1420en/12.2011

System description 3.2.4 Coupling device AGE185 The coupling device AGE185 extends the nominal voltage range of the insulation fault location system EDS309.... It allows connection to nominal voltage ranges up to AC 790 V resp. DC 960 V. 3.3 Operating principle of insulation fault location (I Δs ) When a first insulation fault occurs in IT systems, a residual current flows which is essentially determined by the system leakage capacitances. The basic concept in fault location is therefore to close the fault current circuit for a short period over a defined resistance. As a result of this principle, the system voltage itself drives a test current containing a signal that can be evaluated. The test current is generated periodically by the PGH18... insulation fault test device (which is a component of the EDS309...PG system). Optionally, the test current can also be generated by an IRDH575 or PGH47... insulation fault test device. The test current is limited in amplitude and time. As this happens, the system conductors are connected alternately to earth via a defined resistance. The test current generated in this manner depends on the value of the present insulation fault and the system voltage. The test current of the EDS3090 is limited to a maximum of 25 ma, and when I max = 10mA is set, it is limited to 10 ma. For planning purposes, it should be noted that no system components are present in which this test current can bring about a damaging reaction, even in unfavourable cases. The test current pulse flows from the insulation fault test device via the live parts, taking the shortest path to the location of the insulation fault. From there, it flows via the insulation fault and the earth conductor (PE) back to the insulation fault test device. This test current pulse is then detected by the measuring clamps or measuring current transformers located in the insulation fault path, and is signalled by the connected insulation fault evaluator EDS190P. You must ensure that all live conductors are routed through the measuring clamp. Do not route any PE conductors or shields of shielded conductors through the measuring clamp! Normal commercial measuring clamps are not suitable for the EDS309... and must not be used. Only if these notes are observed will you obtain a true measurement result. Additional information is available in our "Transformer installation" technical information. TGH1420en/12.2011 15

System description 3.3.1 Block diagram EDS system U n L1(L+) IT-System L2(L-) PSA... 3 1 2 PGH... EDS190P R F PE EDS190P PGH... U n PSA... R F PE Insulation fault evaluator Insulation fault test device System voltage IT system Measuring clamp Insulation fault Protective earth conductor 3.3.2 Test cycle The duration of the test current pulse cycle is 6 seconds. The PGH... alternately sends positive and negative test current pulses. The test cycle of the PGH... is shown in different switch positions (1, 2, 3) in the block diagram below (also see block diagram of the EDS system above). Position PGH... 1 3 2 3 1 2 sec 4 sec 2 sec 4 sec EDS Start 16 TGH1420en/12.2011

System description 3.3.3 Terms I Δs Measured value of the selective fault current of the evaluator unit (EDS mode). Residual current created by an insulation fault (RCM mode). I Δn 3.3.4 Currents in the EDS system In addition to the block diagram on page 16, the path of the residual currents and the test current is illustrated in the diagram below: U n IT-System PSA... I Dn, I T 3 1 2 EDS190P PGH... C E-V R F-V C E-N R F-N PE... Test current loop I T........ Residual currents I Δn (example) C E-V C E-N R F-V R F-N Upstream capacitances, system leakage capacitances upstream the measuring current transformer Downstream capacitances, system leakage capacitances downstream the measuring current transformer Insulation fault upstream the measuring current transformer Insulation fault downstream the measuring current transformer The following residual currents flow through the measuring current transformer of the EDS... : The test current I Τ caused by the insulation fault R F-N Residual currents I Δn flowing through the system leakage capacitances C E-V and C E-N resp. caused by R F-V and R F-N, Transient leakage currents caused by switching and control activities in the system, Low-frequency leakage currents caused by the use of converters TGH1420en/12.2011 17

System description 3.4 Operating principle of residual current measurement (I Δn ) In the RCM mode, the EDS309... operates according to the principle of residual current measurement. In this case, only the evaluator unit EDS190P with the measuring clamp is used, the PGH18... insulation fault test device is not required. In accordance with Kirchhoff's Law, the sum of the inflowing currents at every intersection in a system is equal to the sum of the outflowing currents. I to I from I D =0 MESSZANGE / CLAMP ON PROBE Datenblatt / Datasheet : TGH13xx Durchmesser / Diameter : 52 mm Art.-Nr. / Art.-no. : B 980 xxx PSA3052 PE Fig. 3.1: The two currents I to and I from are equal in quantity but have different directions, so that the resultant sum is zero. The EDS190P recognises this, no message is generated. I to I from MESSZANGE / CLAMP ON PROBE Datenblatt / Datasheet : TGH13xx Durchmesser / Diameter : 52 mm Art.-Nr. / Art.-no. : B 980 xxx PSA3052 I D=0 R F PE Fig. 3.2: A portion of the current is flowing away via an insulation fault R F. The sum of the currents is no longer zero. If the residual current is equal to or greater than the response value, the EDS190P will generate a message. In the RCM mode, residual currents can be measured in one and three-phase TT or TN systems. If the system leakage capacitance upstream of the measuring clamp is sufficiently high, the EDS190P can also be used for measurements in one and three-phase IT systems. Its suitability for this purpose must be checked in each individual case. 18 TGH1420en/12.2011

4. Points to be considered before use 4.1 How does an insulation fault location system work? An insulation fault location system consists of a PGH18...insulation fault test device and an EDS190P insulation fault evaluator in combination with a PSA3... measuring clamp. Functional sequence Start insulation fault location by activating the PGH18... insulation fault test device The PGH18... insulation fault test device for a short period connects the live conductors to earth via an electronic current limiting device. A test current I T which is dependent on the system voltage and on the value of the insulation fault flows and closes the fault current circuit. The test current is limited to a maximum value of 25 ma resp. 10 ma (PGH185/186) or 2.5 ma resp. 1 ma (PGH183). The test current pulse flows from the insulation fault test device via the live conductors, the insulation fault R F and the earth conductor (PE conductor) back to the insulation fault test device. This current pulse can be detected by enclosing the outgoing conductors of the distribution point, located in the current circuit, with the measuring clamp and can be evaluated with the EDS190P insulation fault evaluator. By measuring along the cable with the measuring clamp, the point of the fault can be located precisely. PSA... PGH18... EDS190P Fig. 4.1: Function of the EDS system TGH1420en/12.2011 19

Points to be considered before use 4.2 Requirements for reliable insulation fault location The task of the insulation fault evaluator is to detect insulation faults downstream of the measuring clamp RF-N. It is designed to recognise reliably the test current caused by the insulation fault for this purpose. Requirements: The insulation fault must be present for at least 30 seconds. The test current range: for main circuits with EDS3090, EDS3090PG, EDS3090PG-13, EDS3096PG is: It = 2...50 ma for control circuits with EDS3091, EDS3091PG, EDS3091PG-13 is: It = 0.2...5 ma The upstream capacitances C E-V must be at least as large as the downstream capacitances C E-N. The total system leakage capacitance must not exceed the following values: for main circuits with EDS3090, EDS3090PG, EDS3090PG-13, EDS3096PG: up to 30.000 μfv (product of the system leakage capacitance and nominal system voltage) for control circuits with EDS3091, EDS3091PG, EDS3091PG-13: up to 1.000 μfv (product of the system leakage capacitance and nominal system voltage) The sum of the test current and residual current flowing through the measuring clamp and the measuring current transformer must not exceed the following values: for main circuits with EDS3090, EDS3090PG, EDS3090PG-13, EDS3096PG-13: 10 A for control circuits with EDS3091, EDS3091PG, EDS3091PG-13: 1 A There must not be any connections to other sub-distributions downstream a measuring clamp or an installed measuring current transformer, see the illustration below. Fig. 4.2: Connections between sub-distributions lead to measuring errors Not only does the value of the residual current influence the reliable detection of the test current but also the respective frequency of the residual current. Residual currents deviating from the system frequency may be caused by the use of frequency converters, for example. The behaviour of the EDS309... is described in the fault curve illustrated below: When the measured residual current values exceed a value of 10 A in main circuits, the EDS190P outputs the alarm message IΔn>10A. This applies to nominal system frequencies of 50/60/400 Hz for EDS3090, EDS3090PG, EDS3090PG-13, EDS3096PG and EDS3096PG-13. 20 TGH1420en/12.2011

Points to be considered before use When the measured residual current exceeds a value of 1 A in control circuits, the EDS190P outputs the alarm message IΔn>1A. This applies to nominal system frequencies of 50/60/400 Hz foreds3091, EDS3091PG and EDS3091PG-13. When residual currents of nominal system frequencies below 50 Hz occur, the message "Fault" will be generated. Example: When a residual current of 2 A with a frequency of 20 Hz occurs (red dot in the diagram), the insulation fault location system is outside the permissible measuring range and the message "Fault" appears on the display of the EDS190P. Fig. 4.3: A residual current value of 2 A is outside of the permissible frequency range (red dot) Sub-distributions downstream of the measuring clamp must not be galvanically connected with each other, because such connections create disturbing residual currents. As a result, the message "Fault" or "IΔn>10A may be output, for example. Symmetrical insulation faults downstream of the measuring current transformer may not be recognised under certain circumstances. Low-frequency residual currents (caused by converters, for example) may have the effect that insulation faults cannot be found when their frequency is equal or nearly equal the test cycle frequency of the PGH186. Cables leading to the same load in parallel are to be passed together through the measuring clamp during the measurement. TGH1420en/12.2011 21

Points to be considered before use 4.3 Reduced test current Especially in DC control voltage systems in the power station and energy supply utility sector, relays or SPCs might be installed which switch already in case of relatively low currents. In such a case, the switch I max on the PGH18... must be moved to 10/1 ma position. The test current limiting values 10 ma and 25 ma indicated on the switch only applies to DC systems. Prior to measurements with the EDS3090.. with reduced test current (switch position 10/1 ma), it is also necessary to check whether any sensitive system components can be caused to operate unintentionally. 4.4 Characteristic curves on the response sensitivity of EDS190P The type of supply system, system voltage, system frequency, leakage capacitance and test current have an effect on the response sensitivity of the EDS system. The value of the test current can be set at the PGH18... insulation fault test device. Resulting from the type of supply system, the real test current in AC systems is lower than the setting. In comparison to DC systems, the factor is 0.5 in AC systems respectively 0.67 in 3AC systems. For use in AC and 3AC systems, set the response value at the EDS190P as follows: Application Main circuit Control circuit Insulation fault location system Setting EDS190P Maximum test current Menu 2.5: I Δs max Setting PGH18... Test current I T Response range EDS190P Menu 3.2 Setting PGH18... Reduced test current I T Response range EDS190P Reduced test current Menu 3.2 EDS3090 EDS3090PG EDS3090PG-13 EDS3096PG max. 50 ma 25 ma (PGH185/186) Tab. 4.1: Settings on the insulation fault location system EDS3091 EDS3091PG EDS3091PG-13 max. 5 ma 2.5 ma (PGH183) 2...10 ma 0.2...1 ma 10 ma (PGH185/186) 1 ma (PGH183) 2...5 ma 0.2...0.5 ma For details on the setting of the response value, refer to Setting menu 3: (Settings IΔs) on page 37. The response values are shown as characteristic curves. The maximum deviation can be +/- 30 %, including the tolerances of the measuring clamps. The characteristic curves apply to the respective nominal voltage indicated in the diagram. If the nominal voltage of the system being monitored is different from the nominal voltage shown in the diagram, the response values may change proportionally. Nominal voltages changing dynamically during operation or in case of superimposed alternating currents that deviate from the system frequency (e.g. caused by frequency converters) or superimposed direct currents may result in response values that are outside the range displayed in the diagram. The following curves makes light work of determining a correct and practical response value for this EDS190P. When the insulation monitoring device shows an alarm message in a system being monitored, manual insulation fault location can be started. Proceed as follows: 1. Select the characteristics (3 AC, AC, DC) that are appropriate for your type of distribution system. 22 TGH1420en/12.2011

Points to be considered before use 2. From these, select the diagram that best matches the desired system voltage. 3. Calculate the anticipated leakage capacitance of the system being monitored. Insulation monitoring devices of the IRDH... series can display the value of the leakage capacitance (press the INFO key). Apply this value to the diagram in the form of a vertical line. If it is not possible to query the leakage capacitance, the respective highest value is to be taken from the characteristic curve. 4. The curves show the response sensitivity values 2 ma, 5 ma and 10 ma set for the EDS190P for main circuits and 0.2 ma, 0.5 ma and 1 ma for control circuits. Values above the respective curve cannot be detected. Values and characteristics that fall between the top and bottom characteristics can be roughly determined on the basis of those actually provided. 5. Set the respective response value on the EDS190P. 6. The curves for DC 24 V and AC 42 V do not apply to the EDS3096 because the insulation fault test device works with its own test voltage of DC 50 V. For this reason, the curves for DC 60 V and AC 110 V are valid for these nominal voltages. 4.4.1 Response characteristic curves for main circuits in 3AC systems Re [kohm] Re [kohm] 80 70 60 50 40 30 20 10 0 200 180 160 140 120 100 80 60 40 20 0 3AC 230 V 2mA 5mA 10mA 0 50 100 150 Ce [µf] 3AC 500 V 2mA 5mA 10mA 0 10 20 30 40 50 60 Ce [µf] Re [kohm] Re [kohm] 140 120 100 80 60 40 20 3AC 400 V 2mA 5mA 10mA 0 0 20 40 60 80 100 Ce [µf] 250 200 150 100 50 0 3AC 690 V 2mA 5mA 10mA 0 10 20 30 40 50 Ce [µf] TGH1420en/12.2011 23

Points to be considered before use 4.4.2 Response characteristic curves for main circuits in AC systems Re [kohm] 8 6 4 2 AC 42 V 2mA 5mA 10mA 0 0 50 100 150 200 250 300 Ce [µf] Re [kohm] 25 20 15 10 5 AC 110 V 2mA 5mA 10mA 0 0 50 100 150 200 250 300 Ce [µf] Re [kohm] 50 45 40 35 30 25 20 15 10 5 0 AC 230 V 2mA 5mA 10mA 0 50 100 150 Ce [µf] Re [kohm] 100 80 60 40 20 AC 400 V 2mA 5mA 10mA 0 0 20 40 60 80 100 Ce [µf] 4.4.3 Response characteristic curves for main circuits in DC systems Re [kohm] Re [kohm] 10 9 8 7 6 5 4 3 2 1 0 60 50 40 30 20 10 DC 24 V 2mA 5mA 10mA 0 100 200 300 400 500 Ce [µf] DC 110 V 2mA 5mA 10mA 0 0 50 100 150 200 250 300 Ce [µf] Re [kohm] Re [kohm] 30 25 20 15 10 5 DC 60 V 2mA 5mA 10mA 0 0 100 200 300 Ce [µf] 100 90 80 70 60 50 40 30 20 10 0 DC 230 V 2mA 5mA 10mA 0 50 100 150 Ce [µf] 24 TGH1420en/12.2011

Points to be considered before use 4.4.4 Response characteristic curves for control circuits in AC systems Re [kohm] 80 60 AC 42 V 0,2mA 0,5mA 1,0mA Re [kohm] 200 150 AC 110 V 0,2mA 0,5mA 1,0mA 40 100 20 50 0 0 5 10 15 20 25 Ce [µf] 0 0 2 4 6 8 10 Ce [µf] Re [kohm] 600 500 400 300 200 100 AC 230 V 0,2mA 0,5mA 1,0mA 0 0 1 2 3 4 5 6 Ce [µf] 4.4.5 Response characteristic curves for control circuits in DC systems Re [kohm] Re [kohm] 100 90 80 70 60 50 40 30 20 10 0 500 400 300 200 100 0 DC 24 V 0,2mA 0,5mA 1mA 0 10 20 30 40 50 60 Ce [µf] DC 110 V 0,2mA 0,5mA 1,0mA 0 2 4 6 8 10 Ce [µf] Re [kohm] Re [kohm] 250 200 150 100 50 DC 60 V 0,2mA 0,5mA 1,0mA 0 0 5 10 15 20 Ce [µf] 800 600 400 200 DC 230 V 0,2mA 0,5mA 1,0mA 0 0 1 2 3 4 5 6 Ce [µf] TGH1420en/12.2011 25

Points to be considered before use 26 TGH1420en/12.2011

5. Commissioning and connection Prior to commissioning make sure that the supply voltage of the PGH18... and of the power supply unit (as appropriate) corresponds to the voltage of the supplying system. When the devices are operated with wrong supply voltage, the devices may be damaged. Prior to commissioning, please check that all system components are connected to each other. 5.1 Decoupling the insulation monitoring device While insulation fault location is being undertaken with the EDS309..., an existing insulation monitoring device must be disconnected from the system for the duration of the fault location, if its internal resistance R i is < 120 kω. This must be done by effecting an all-pole interruption of the system coupling, it is not sufficient to switch off the supply voltage to the insulation monitoring device. When a device is used with an R i of 120 kω, the influence is negligible, and in this case there is no need to disconnect. However, take into consideration that the PGH influences the measurements of the insulation monitoring device. 5.2 Deenergised systems For insulation fault location in deenergised systems with EDS3096PG, the integrated voltage source (G) of the PGH186 provides a test voltage of DC 50 V. The test voltage DC 50 V supplied by the PGH186 is available at the socket L1(+). Make sure that this socket is connected to the system to be monitored. Only in this way, the integrated voltage source of PGH186 will be available. Please note that all live conductors of the system to be searched must be connected to each other via loads or the deenergised power supply. U S = 0 V L1(L+) L2(L-) IT-System PSA... + G - L1 EDS190P 3 R F PE 1 2 PGH186 TGH1420en/12.2011 27

Commissioning and connection 5.3 Connection to an IT system Connect the EDS309... as described below: 3 AC - System 3/N AC - System Un L1 L2 L3 N PE AC - System Un L1 L2 PE PE L1 L2 L3 PE L1 L2 DC - System Un L+ L- L1 L2 If the terminals L1, L2, L3 (resp. L1, L2) of the device are connected to a live system under operation, the terminal must not be disconnected from the protective conductor (PE). 28 TGH1420en/12.2011

6. Operation 6.1 Brief description of insulation fault location (EDS mode) 6.1.1 Commissioning of the PGH18... for test current supply 1. First, connect the PGH18... to the PE of the system to be checked, see page 28 2. Then connect the PGH18... to active conductors 3. Connect the device to U S and switch it on If the test current I T is to be generated by an IRDH575, its menu item EDS-Setup has to be set to EDS=On. 6.1.2 Insulation fault location with EDS190P 1. Connect the measuring clamp to the EDS190P 2. Switch the device on with the On/off button 3. A self test is carried out, wait until the message OK appears 4. Check whether the right measuring clamp has been set on the EDS190P 5. Enclose the PE conductor between PGH18... (IRDH575) and/or the PE bar with the measuring clamp in order to prove the test current I T 6. Enclose the functionally related active conductors of the respective sub-distributions with the measuring clamp. Warning! Do not enclose the PE! 7. Read and evaluate the measured value. If the set response value has been exceeded, the message alarm appears on the display with the alarm LED flashing. TGH1420en/12.2011 29

Operation 6.2 Operating elements of the PGH18... 1 8 ON 1 7 Us 25mA Imax 2 6 M 100mA ON 10mA 3(N)AC 0...575V mit/with 500...790V DC 0...504V AGE185 400...960V L1(+) L2(-) L3 PGH186 3 5 4 1 ON/OFF switch, activates the test current 2 Selector switch for the maximum test current 25 / 10 ma or 2.5 / 1 ma 3 Not visible: Magnetic adhesive strip at the back of the enclosure for fixing to metal parts (e.g. switchboard cabinet) 4 3 sockets for system coupling 5 Socket for PE connection 6 LED indicators: Power ON LED Indication of the positive test cycle of the test current Indication of the negative test cycle of the test current 7 Microfuse 100 ma 8 Panel plug for supply voltage 30 TGH1420en/12.2011

Operation 6.3 Display and operating elements of the EDS190P 1 2 3 4 5 6 12 11 10 7 8 9 1 Connection for external power supply unit DC 6 V 2 BNC connection for the measuring clamp 3 LC display, illuminated 3 lines a 16 characters 4 Alarm LED, lights when the response value is exceeded 5 6 7 I Ds I Dn INFO ESC Button for the selection of the operating mode: I ΔS = Insulation fault location in IT systems (EDS mode) I Δn = Residual current measurement in TN-S systems (RCM mode) Button to select the measuring current transformer for I Tmax = 50 ma: for I Tmax = 5 ma: P20 = PSA3020 = PSA3320 P52 = PSA3052 = PSA3352 P165 = PSA3165 --------------- W/WR = W... / WR... = W...-8000 WS = WS... = W...-8000 INFO key: - Device type - Software version - Current response values I ΔS and I Δn - Setup status ESC key: Exits the menu function without changing parameters TGH1420en/12.2011 31

Operation 8 MENU MENU key: To start the Menu mode Enter key: To confirm changed parameter values or the selected menu items 9 On-Off button 10 Illumination button: On /Off switching of the display illumination 11 RESET RESET button: To clear the fault memory DOWN key: To move down in the menu, to decrease the parameter value 12 HOLD HOLD button: To save the measured value UP key: To move up in the menu, to increase the parameter value 32 TGH1420en/12.2011

Operation 6.4 Operation of the EDS190P 6.4.1 Switching the device on and off 1. Prior to commissioning, connect a measuring clamp (e.g. PSA3052) to the EDS190P! 2. Switch the device on by means of the On/Off button. Once the device is switched on, the self test is started. When the self test runs correctly, the message "Test OK appears on the display. The device is factory set to the EDS mode. Press the On/Off button for approximately 2 seconds to switch the device off. 1. Display indication when starting for approx. 3 s EDS190P BENDER GmbH&CoKG D-35305 Grünberg 2. Display indication when starting for approx. 10 s EDS190P Self-test >> >> >> >> 3. Display indication when starting for approx. 3 s EDS190P Self-test TEST OK Fig. 6.1: Starting sequence of the EDS190P 6.4.2 Display illumination provides improved readability Press the illumination button on the bottom left in order to improve the readability of texts and symbols. By pressing the button again the illumination can be switched off. 6.4.3 Switching between the operating modes insulation fault location I ΔS and residual current measurement I Δn Here, the measuring functions can be selected. I Δn for residual current measurement preferably for TN-TT systems. I Δs for insulation fault location in IT systems. Avoid changing the operating mode during insulation fault location. TGH1420en/12.2011 33

Operation 6.4.4 Display elements and their meaning Insulation fault location is carried out in the EDS mode, as illustrated in the figure below. 12 1 11 2 10 3 9 8 7 6 5 4 1 Progress bar to show the measurement progress in the EDS mode 2 Indication of the test current pulse: = positive impulse, idle time, = negative impulse 3 Type of distribution system: AC, DC 4 Hold function activated; Measured value indication "frozen 5 Charge status of the accumulators 6 Alarm output activated via LED 7 Loudspeaker symbol visible: An existing alarm will also be output acoustically. 8 Fault memory M is activated 9 10 Selected measuring current transformer for I Tmax = 50 ma: for I Tmax = 5 ma: P20 = PSA3020 = PSA3320 P52 = PSA3052 = PSA3352 P165 = PSA3165 --------------- W/WR = W... / WR... = W...-8000 WS = WS... = W...-8000 Selection of the measuring sensitivity = Control circuit = I Tmax = 5 ma = Main circuit = I Tmax = 50 ma 11 I Δn = Indication of the currently flowing residual current 12 I ΔS = Indication of the currently flowing test current 34 TGH1420en/12.2011

Operation 6.5 Standard displays of the EDS190P 6.5.1 Standard display without enclosing the cable to be measured The device is in the EDS mode (I ΔS ). I ΔS will not be indicated, because no conductor is enclosed with the measuring clamp. I s = 0mA >> >> >> I n < 100mA P52 M H AC 6.5.2 Standard display in the EDS mode (I ΔS ) with the cable enclosed The display shows a measured fault current I ΔS of 10 ma. A new measurement is being carried out. This is indicated by the progress bar represented as an angle. I s = 10mA >> >> >> I n < 100mA P52 M H AC Please note that only 50% of the value of the test current I T created by the PGH18... in AC systems is indicated by the EDS190P. One-way rectifiers used in the PGH18... decreases the indicated value in AC systems to 50 %, in 3AC systems to 67 %. 6.5.3 Standard display in the RCM mode (I Δn ) with the cable enclosed The display shows a measured residual current I Δn of 160 ma. The set residual current response value is 1000 ma. I n = 160mA Resp. = 1000mA P52 M H AC The following display shows a standard indication with menu item "4.Harmonics on activated. This setting is only possible for systems with a frequency of 50 Hz and 60 Hz. The display shows a measured current of 4 ma as well as harmonic distortion of 64 % for the first harmonics. I n = 6.0mA H1=4mA THD=64% P52 M H 50Hz 6.6 Alarms in the EDS or RCM mode When one of the set response values I Δs or I Δn are exceeded, the message alarm appears on the display. I s = 10mA Alarm Next Measurement P52 M H AC Alarm during insulation fault location I n = 160mA Alarm Resp. = 100mA P52 M H AC Alarm during an RCM measurement TGH1420en/12.2011 35

Operation 6.7 Indication of device and measuring errors Fault messages possible to occur are explained in the table below. No CT connected P52 M H AC Short Circuit CT P52 M H AC I s = 0mA Fault I n < 100mA P52 M H AC No measuring clamp or no measuring current transformer at the measuring input or wrong measuring current transformer connected Actions: Connect the appropriate measuring clamp or measuring current transformer Short circuit in the measuring clamp or measuring current transformer or wrong transformer type connected. Actions: Connect intact and appropriate measuring clamp A fault occurred during insulation fault location (EDS mode). Possible causes: The measuring clamp is not held steady. A residual current is flowing through the measuring clamp which disturbs the measurement. A magnetic field exists in the vicinity of the measuring clamp which disturbs the EDS measurement. 6.8 Factory settings EDS190P (delivery condition) Most of the parameters are set in the menu. If this is not the case, the setting is market with (button). Button operating mode: I Δs (EDS mode = insulation fault location) Button transformer selected: Measuring clamp PSA3052 (EDS3090 and 3096) Measuring clamp PSA3352 ( EDS3091) Button illumination: off Memory: off Alarm LED: on Buzzer: on Test current I T max: 50 ma (EDS3090 and 3096) 5 ma (EDS3091) Response value (for IΔs): 5 ma (EDS3090 and 3096) 500 μa (EDS3091) Type of distribution system (for IΔs): AC System with converter (for IΔs): no Response value (for IΔn): 100 ma System frequency (for IΔn): 50 Hz Measurement of the harmonics (for IΔn): off Language in the display: English Time: CET 36 TGH1420en/12.2011

Operation 6.9 Menu structure A schematic sketch of the menu structure is shown below. Level 1 Level 2 Level 3 1. Exit 2. Settings 1. Exit 2. General 1. Exit 2. Memory: on/off 3. Buzzer: on/off 4. AlarmLED: on/off 5. I T max: 5mA / 50mA 3. View harmonics 4. Service 3. IΔs 1. Exit 2. Resp.: 2...10mA / 200...1000μA 3. System type: AC/DC 4.Inverter: yes / no 4. IΔn 1. Exit 2. Resp: 10...10000mA 3. Freq: 50Hz / 60Hz / up to 2kHz 4. Harmonics: on/off 5. System 1. Exit 2. Language: German / English / French 3.Clock 1. Exit 2. H1= 0 ma 3. H2= 0 ma... 9. H8= 0 ma 10. H9= 0 ma For service purposes only This menu item exclusively serves the purpose of displaying the harmonics from H1 to H9. If you want to view the occurring harmonics in the standard display outside the menu, you have to activate the menu item "4. Harmonics: 6.10 Navigation within the menu - Starting the menu mode with MENU - Selection of the menu item or confirming a a value with Enter MENU - Navigating up or down in the menu - increasing or decreasing values HOLD RESET ESC: - To exit the selected menu item - To exit the modified setting without saving INFO ESC TGH1420en/12.2011 37

Operation All menu descriptions below are based on the factory settings. These settings are given in brackets after the menu items of level 3. 6.11 Menu item: Settings / General Alarms are always signalled on the display. In delivery condition, alarms are also signalled by an alarm LED and a buzzer. You can use these menu items to set whether: alarms are to be saved alarms are not to be signalled acoustically alarms are not to be signalled by an alarm LED the measuring sensitivity of the EDS190P is to be adapted to the test current of a control or main circuit. A maximum test current I T of 5 ma is to be used for control circuits, and maximum test current of 50 ma for main circuits. Level 1 Level 2 Level 3 2. Settings 1. Exit 2. General 1. Exit 2. Memory: on / off (off) 3. Buzzer: on / off (on) 4. AlarmLED: on / off (on) 5. I T max: 5mA / 50mA (50mA), (EDS3090/3096) (5mA), (EDS3091) 6.12 Menu item: Settings / IΔs Use this menu item to set all relevant parameters for insulation fault location: the I ΔS response value for control circuits in the range of 200...1000 μa. This value range is specified by the value I T max = 5 ma. Or the I ΔS response value for main circuits in the range of 2...10 ma. This value range is specified by the value I T max = 50 ma. Adaption to the system to be monitored: AC or DC. Select yes, if a converter is operated in the system to be monitored. Level 1 Level 2 Level 3 2. Settings 1. Exit 3. IΔs 1. Exit 2. Response value: 2...10mA / 200...1000μA 3. Supply system: AC/DC 4. Inverter: yes / no 38 TGH1420en/12.2011

Operation 6.13 Menu item: Settings / IΔn Use this menu item to set all relevant parameters for residual current measurement: Set the I Δn response value between 10 ma and 10 A. Set the frequency of the system being monitored here. If you want to view the currents of the occurring harmonics on the standard display, activate the menu item "4. Harmonics. When the Harmonics menu has been activated, please note that only system frequencies of 50 Hz and 60 Hz can be selected. Level 1 Level 2 Level 3 1. Exit 2. Settings 1. Exit 4. IΔn 1. Exit 2. Resp.: 10...10000mA 3. Freq.: 50Hz / 60Hz / up to 2kHz 4. Harmonics: on/off 6.14 Menu item: Settings / system Use this menu item to select the appropriate display language and set the correct date and time. For setting the date, different formats can be selected. Level 1 Level 2 Level 3 1. Exit 2. Settings 1. Exit 5. System 1. Exit 2. Language: German / English / French 3.Clock 6.15 Menu item: View harmonics (Harmonics) This menu item exclusively serves the purpose of displaying the harmonics from H1 to H9. Level 1 Level 2 Level 3 1. Exit 3. View Harmonics 1. Exit 2. H1= 0 ma 3. H2= 0 ma... 9. H8= 0 ma 10. H9= 0 ma This menu item exclusively serves the purpose of displaying the harmonics from H1 to H9. If you want to view the occurring harmonics in the standard display outside the menu, you have to activate the menu item "4. Harmonics: on/off. TGH1420en/12.2011 39

Operation 6.16 Practical use 6.16.1 Use as a portable insulation fault location system The primary application of the EDS309... is as a portable insulation fault location system in IT systems. After all the information of the chapter Points to be considered before use auf Seite 19 has been considered, the actual fault location operation may be started. Proceed as follows: 1. Check that the nominal system voltage is within the permissible limits. 2. Connect up the PGH18... near the supply input. When you do this, you must comply with the general guidelines for live work! Before making a connection to the system to be checked, connect the green-yellow conductor over the PE socket of the PGH18... with the PE of the system. Only then, connect the PGH18... to the system to be checked using the connecting cable supplied with the device Three-phase system Connect the sockets L1, L2 and L3. Single-phase system AC or DC Connect the sockets L1 and L2. 3. Connect the PGH18... to a suitable supply voltage (see nameplate) using the power supply cable supplied with the device. 4. If the insulation monitoring device which is present in the IT system has an internal resistance of < 120 kω, effect an all-pole interruption of the system coupling. It is not sufficient to switch off the supply voltage to the insulation monitoring device. 5. Set the switch position I max on the PGH18... Refer to the instructions in the chapter Reduced test current auf Seite 22. 6. Switch the PGH18... on. The "ON" LED must light up, the two LEDs " " and " " must light up in time with the cycle and then go out again. If the LEDs fail to show any activity whatsoever, the supply voltage and the microfuse installed in the PGH18... should be checked. 7. Connect a suitable measuring clamp or a measuring current transformer to the EDS190P. 8. Switch on the EDS190P by pressing the On/Off button. 9. Make the following settings: Select the function I ΔS (EDS mode) by pressing the button Set the maximum sensitivity: 50 ma for main circuits for EDS3090, EDS3090PG, EDS3090PG-13, EDS3096PG-13, the measuring clamps PSA3020, PSA3052, PSA3165 and the measuring current transformers W/ WR, WS. 5 ma for control circuits for EDS3091, EDS3091PG, EDS3091PG-13, the measuring clamps PSA3320, PSA3352 and the measuring current transformers W 8000, WS 8000 Select the measuring clamp or the measuring current transformer to be used with the button. Set the supply system of the system to be monitored in the menu 2.3 (setting IΔs). Select yes in menu 3 (setting IΔs) if frequency converters are connected to the sub-distributions to be checked. 10. When using measuring clamps please note: Do not connect the core of the measuring clamp to system voltages above the nominal insulation voltage. Keep the contact surfaces of the measuring clamp clean. 40 TGH1420en/12.2011

Operation The measuring clamp should not be used in the immediate vicinity of devices which generate magnetic fields, such as transformers or throttles, nor in the vicinity of adjacent conductors with high operating currents. Do not disconnect the measuring clamp from the EDS190P when live conductors are routed through the measuring clamp. Failure to observe this can destroy the measuring clamp! Inside the measuring clamp, you should aim for the maximum possible symmetry of the conductors. Due to excessive load current, the measuring clamp can reach a saturation state that may cause an alarm message IΔn >10 A. Keep the measuring clamp steady during the measurement! Make sure that you do not exert any pressure on the measuring clamp arms. 11. Enclose the green-yellow conductor with the measuring clamp between the PGH18... and earth. When the EDS190P does not react, the insulation fault is too high and cannot be found. Recognised test current pulses are indicated by the symbol. 12. Start insulation fault location at the main distribution point in the IT system. Enclose all system conductors, but not the PE conductor, with the measuring clamp. For each measurement, wait for one test cycle (approx. 30 seconds). An alarm message on the EDS190P display signals an insulation fault downstream of the measuring clamp. It is recommended to carry out fault location with the buzzer activated. The EDS190P can display the following messages during insulation fault location: No CT connected: Measuring clamp or measuring current transformer not connected or defective. Fault: The measuring clamp is not held steady. A residual current disturbing the EDS measurement is flowing through the measuring clamp. A magnetic field exist in the vicinity of the measuring clamp which disturbs the EDS measurement. In these cases, the insulation fault cannot be located in the respective sub-distributions resp. at the location of measurement. IΔn >10A / >1A: A residual current of > 10 A bzw. >1A flows through the measuring clamp. In this case, the insulation fault cannot be located in the respective sub-distribution. Residual currents of this size occurring in an IT system can be caused by high system leakage capacitances or by multiple insulation faults. Therefore, it is possible that this alarm message also signals an insulation fault in this sub-distribution. >>>>: Measurement is running, this display shows the progress of the measurement. This process will be completed after approximately 30 seconds. Next measurement: No insulation fault found in this sub-distribution. The measuring clamp or the measuring current transformer can be moved to the next sub-distribution. Alarm...mA: An insulation fault has been detected in this sub-distribution. Measurement should be continued along this conductor. 13. Measure along the conductor with the EDS190P until the fault is found. Penetrate radially into the sub-distributions as you do this. The fault location is found when the test current generated by the PGH18... downstream of the measuring clamp at least exceeds the preset response TGH1420en/12.2011 41

Operation value of the EDS190P. For operating currents < 10 A, it is also possible to enclose one conductor only. For currents > 10 A, this may produce the effect that the measuring clamp can no longer be opened. This danger is particularly present in DC systems. If this behaviour occurs, under no circumstances use force, since this would destroy the measuring clamp. Instead, you must disconnect the respective system. After this has been done, the measuring clamp can be opened without the application of force. 6.16.2 Using the EDS190P within a permanently installed EDS system The EDS190P can also be used in a permanently installed EDS system (EDS460/490 resp. EDS461/ 491). In extended IT systems with a number of sub-distributions, often only the main distributions are monitored by a permanently installed EDS system. When the main distribution where the insulation fault exists is recognised, the search will be continued from that point using the EDS190P. For this purpose, the EDS190P uses the test current pulse of the permanently installed EDS system (IRDH575, PGH47...). The PGH18... is not required for this application. The scope of delivery of the EDS3090 and EDS3091 systems does not include a PGH18... Insulation fault location can only be carried out in energised IT systems. Also observe the operating instructions of the permanently installed EDS system. Example: The insulation monitoring device has signalled an insulation fault below its response value and has started the permanently installed EDS system. The main distribution affected by an insulation fault has been recognised. Continue insulation fault location as follows: 1. Set the EDS system mode to permanent insulation fault location: IRDH575: Set "EDS on" PGH471: Press the "Start/Stop" button 2. Connect a suitable measuring clamp to the EDS190P. 3. Switch on the EDS190P by pressing the On/Off button. 4. Make the following settings: Select function IΔs (EDS mode) with the button Set the maximum sensitivity: 50 ma for main circuits for EDS460/490 for the measuring clamps PSA3020, PSA3052, PSA3165 and the measuring current transformers W/WR, WS 5 ma for control circuits for EDS461/491 for the measuring clamps PSA3320, PSA3352 and measuring current transformers W 8000, WS 8000 Select the measuring clamp or the measuring current transformer to be used with the button. Set the supply system of the system to be checked in the menu 2.3 (setting IΔs). Select yes in menu 2.3 (setting IΔs) if frequency converters are connected to the sub-distributions to be tested. 5. When using measuring clamps, please note: Do not connect the core of the measuring clamp to system voltages above the nominal insulation voltage. 42 TGH1420en/12.2011

Operation Keep the contact surfaces of the measuring clamp clean. The measuring clamp should not be used in the immediate vicinity of devices which generate magnetic fields, such as transformers or throttles, nor in the vicinity of adjacent conductors with high operating currents. Do not disconnect the measuring clamp from the EDS190P when live conductors are enclosed by the measuring clamp. Otherwise the measuring clamp may be destroyed! Inside the measuring clamp, you should aim for the maximum possible symmetry of the conductors. Due to excessively high load current, the measuring clamp can reach a saturation state that may cause an alarm message IΔn >10A. Keep the measuring clamp steady during the measurement! Make sure that you do not exert any pressure on the measuring clamp arms. Enclose the green-yellow conductor with the measuring clamp between the IRDH575 resp. PGH47... and earth. When the EDS190P does not react, the insulation fault is too high and cannot be found. Recognised test current pulses are indicated by the symbol. 6. Start insulation fault location in the sub-distribution of the IT system recognised to be faulty. Enclose all system conductors, but not the PE conductor, with the measuring clamp. For each measurement, wait for one test cycle (approx. 30 seconds). An alarm message on the EDS190P display signals an insulation fault downstream of the measuring clamp. It is recommended to carry out fault location with the buzzer activated. The EDS190P can display the following messages during insulation fault location: No CT connected: Measuring clamp or measuring current transformer not connected or defective. Fault: Measuring clamp is not held steady. A residual current flows through the measuring clamp affecting the EDS measurement. A magnetic field exist in the vicinity of the measuring clamp which disturbs the EDS measurement. In these cases, the insulation fault cannot be located in the respective sub-distributions resp. at the location of measurement. Idn >10A / >1A: A residual current of > 10 A resp. >1A flows through the measuring clamp. In this case, the insulation fault cannot be located in the respective sub-distribution. Residual currents of this size occurring in an IT system can be caused by high system leakage capacitances or by multiple insulation faults. Therefore, it is possible that this alarm message also signals an insulation fault in this sub-distribution. >>>>: Measurement is running, this display shows the progress of the measurement. This process will be completed after approximately 30 seconds. Next measurement: No insulation fault found in this sub-distribution. The measuring clamp or the measuring current transformer can be moved to the next sub-distribution. Alarm...mA: An insulation fault has been detected in this sub-distribution. Measurement should be continued along this conductor. 7. Measure along the conductor with the EDS190P until the fault is found. Penetrate radially into the sub-distributions as you do this. The fault location is found when the test current through the measuring clamp generated by the IRDH575 resp. PGH47... at least exceeds the preset response value of the EDS190P. TGH1420en/12.2011 43

Operation 6.16.3 EDS309... in diode-decoupled DC systems In some applications DC systems are diode decoupled. Between these decoupled circuits compensating currents may occur. The quantity of the currents and its direction depend on the system voltage, the characteristics of the diodes and the kind of loads installed in the system. When the EDS309... insulation fault location system is used in such systems, the aforementioned compensating currents will disturb the EDS309... and will cause measuring faults. Therefore Bender recommends the use of the EDS309... in diode decoupled systems according to the drawing illustrated on the following page. Please consider the following: Always use two identical measuring clamps. Note: do not forget to set the correct measuring clamp in the corresponding menu of the EDS190P. For this purpose, use the EDS190P-Set (see ordering information). Do not exceed the max. length of the coaxial cable of 10 m (per measuring clamp). Using two measuring clamps will reduce the sensitivity of by 10 %. Always use the two measuring clamps in a way, that the energy flow direction corresponds to the marking on the measuring clamp P1 => P2. The central insulation monitoring device has indicated an insulation fault which is below the insulation value that can be detected with the EDS system. Please consider the information given in "chapter 4. Points to be considered before use" and then start insulation fault location operation. Proceed as follows: 1. Read off the current insulation resistance from the insulation monitoring device. If the value of the insulation resistance is lower than the insulation fault detectable in the EDS system, connect two appropriate measuring clamps to the EDS190P, which are identical (e.g 2 x PSA3020 or 2 x PSA3052). 2. Switch on the EDS190P by pressing the On/Off button. 3. Make the following settings: Select the EDS mode with the function key IΔs Set the maximum sensitivity in menu 2.2 (General settings): 50 ma for main circuits for EDS3090, EDS3090PG, EDS3090PG-13, EDS3096PG, EDS3096PG- 13 for the measuring clamps PSA3020, PSA3052, PSA3165 and the measuring current transformers W/WR, WS 5 ma for control circuits for EDS3091, EDS3091PG, EDS3091PG-13 for the measuring clamps PSA3320, PSA3352 and the measuring current transformers W 8000, WS 8000 Select the measuring clamp or measuring current transformer to be used with the button. 4. Set the supply system of the system to be checked in the menu 2.3 (setting IΔs). 5. If frequency converters are connected to the sub-distributions to be tested, the function inverter in the menu 2.3 (setting IΔs) has to be activated 6. Connect the PGH18... according to the wiring diagram on page 45 to the test current supply inputs. 44 TGH1420en/12.2011

ALARM RESET EDS190P HOLD I Ds IDn MENU INFO ESC AC/DC ALARM RESET EDS190P HOLD I Ds IDn MENU INFO ESC Operation DC main distribution (DC 20...360 V) L+ Central coupling of the Insulation Monitoring Device (IMD) and the test device PGH185 L- S1 Selector switch EDS/IMD Us AC 230 V PGH185 Insulation monitoring device e.g. IRDH275/375 ON L- L+ Us 25 ma Imax 100mA ON 10 ma PSA3052/3020 MESSZANGE / CLAMP ON PROBE Datenblatt / Datasheet : TGH13xx Durchmesser / Diameter : 52 mm Art.-Nr. / Art.-no. : B 980 xx PSA3052 P1 PGH186 L1(+) L2(-) L3 l max. = 10 m MESSZANGE / CLAMP ON PROBE Datenblatt / Datasheet : TGH13xx Durchmesser / Diameter : 52 mm Art.-Nr. / Art.-no. : B 980 6xx PSA3052 P1 P2 l max. = 10 m EDS190P PSA3052/3020 P2 DC sub distribution L+ L- PSA3052/3020 MESSZANGE / CLAMP ON PROBE Datenblatt / Datasheet : TGH13xx Durchmesser / Diameter : 52 mm Art.-Nr. / Art.-no. : B 980 xxx PSA3052 Load Insulation fault EDS190P Load Fig. 6.2: Insulation fault location in a diode-decoupled DC system (wiring diagram) TGH1420en/12.2011 45

Operation 7. Start of the EDS system: Switch the PGH18... on. The "ON" LED lights up and the two LEDs and light up in time with the test cycle and then go out again. If the LEDs fail to show any activity whatsoever, the supply voltage and the microfuse installed in the PGH18... should be checked. Now enclose the L+ and L- conductors with the measuring clamp. Do not enclose the PE conductor. 8. Fault location in the system: Enclose the supply conductors connected to the redundant loads with one measuring clamp each. Make sure to enclose the correct corresponding supply conductors to a diode decoupled load. Check that the energy flow direction of the two measuring clamps is identical (see wiring diagram). For this purpose, the measuring clamps are marked with an arrow. Enclose systematically and one after the other all parallel conductors to the loads with the two measuring clamps. Sections of the loads where insulation faults exist are indicated on the EDS190P display. The alarm messages are output in the same way as they are output when a single measuring clamp is used. Alarm messages, see page 43. 46 TGH1420en/12.2011

Operation 6.16.4 Using the EDS190P as a residual current monitor The EDS190P can also be used as a residual current monitor in TN and TT systems, and provided that certain conditions are fulfilled, it can also be used in IT systems. Residual current measurement is only possible in energised systems. The PGH18... is not required for this application. 1. Check that the nominal system voltage is within the permissible limits. 2. Connect a suitable measuring clamp to the EDS190P an. 3. Switch on the EDS190P by pressing the On/Off button. 4. Make the following settings: Select function IΔn (RCM mode) with the button Set the response value in menu 2.4 (settings IΔn) Select the appropriate measuring clamp or measuring current transformer with the button for the selection of the measuring clamp. 5. When using measuring clamps, please note: Do not connect the core of the measuring clamp to system voltages above the nominal insulation voltage. Enclose all system conductors, but not the PE conductor, with the measuring clamp. Do not enclose shielded cables. Keep the contact surfaces of the measuring clamp clean. The measuring clamp should not be used in the immediate vicinity of devices which generate magnetic fields, such as transformers or throttles, nor in the vicinity of adjacent conductors with high operating currents. Do not disconnect the measuring clamp from the EDS190P when live conductors are enclosed by the measuring clamp. Otherwise the measuring clamp may be destroyed! Inside the measuring clamp, you should aim for the maximum possible symmetry of the conductors. Due to excessively high load current, the measuring clamp can reach a saturation state that may cause an alarm message IΔn >10A. Keep the measuring clamp steady during the measurement! Make sure that you do not exert any pressure on the measuring clamp arms. 6. Start insulation fault location at the main distribution point in the system. Measure along the conductor with the EDS190P until the fault is found. Penetrate radially into the sub-distributions as you do this. 7. EDS190P indicates the residual current at each measuring point. If the residual current is greater than the set response value, the "ALARM" LED lights and the measured value will be indicated. An acoustical signal will also be given provided that the buzzer is activated. 8. For extended period measurements at one point of the system, the fault memory must be activated in menu 2.2 (settings memory). In this way, it is also possible to find intermittent residual currents, provided that they are higher than the set response value. The highest measured residual current is stored. TGH1420en/12.2011 47

Operation 6.16.5 Measuring harmonics The harmonics of the basic frequencies of 50 and 60 Hz can also be measured with the EDS190P. 1. Switch on the EDS190P by pressing the On/Off button. 2. Make the following settings: Select function IΔn (RCM mode) with the button Set the response value in menu 2.4 (settings IΔn): Select the measuring clamp or the measuring current transformer to be used with the button. Select the system frequency in menu 2.4 (settings IΔn) Activate the measurement for the harmonics in menu 2.4 (settings IΔn) Select the appropriate harmonics in menu 3. EDS190P indicates the residual current of the set harmonics at each measuring point. If the residual current is greater than the set response value, the "ALARM" LED lights and the measured value will be indicated. An acoustical signal will also be given provided that the buzzer is activated. 48 TGH1420en/12.2011

ON ALARM RESET EDS190P HOLD IDs IDn MENU INFO ESC Operation 6.17 Coupling device AGE185 for higher voltages This is possible for the device versions EDS3090PG, EDS3090PG-13 and EDS3096PG including the insulation fault test device PGH185 and PGH186. The coupling device AGE185 extends the nominal voltage range of the insulation fault location system EDS309.... It reduces the power dissipation in the PGH18... insulation fault test device and allows the connection of the EDS309... to nominal voltages of up to AC 790 V resp. DC 960 V. Installation, connection and commissioning Connection and commissioning only by skilled persons! The current safety regulations must be considered. Connect the wires of the AGE185 according to your individual requirements to the terminals PE of the system and to the PE socket of the PGH186; No polarity is to be considered. Wiring diagram IT-System PE Us PGH186 Us 25 ma Imax 100mA ON 10 ma PGH186 L1(+) AC/DC L2(-) L3 PSA3052 To the loads MESSZANGE / CLAMP ON PROBE Datenblatt / Datasheet : TGH13xx Durchmesser / Diameter : 52 mm Art.-Nr. / Art.-no. : B 980 6xx AGE185 EDS190P Fig. 6.3: Wiring diagram EDS309... with AGE185 TGH1420en/12.2011 49

Operation 6.18 Power supply of the EDS190P Supply via 3 NiMH cells, 1.2 V or 3 Mignon cells, type LR6 AA, 1.5 V. Also when the device is supplied by a power supply unit, 3 functional accumulators must be available in the battery compartment. Do not connect the power supply unit when batteries are inserted. 6.18.1 Displaying the battery status Four different charge statuses can be indicated on the display: 100 %, 50 %, 25 % and an empty icon to show that the battery is used up. 6.18.2 Replacing batteries or accumulators The battery compartment is located on the rear side of the EDS190P. When the batteries resp. accumulators are replaced, the device parameters of the EDS190P that have been set will remain the same. 1. Unscrew the two screws of the cover on the rear side, remove the cover. 2. Remove the used batteries resp. accumulators. 3. Insert the new batteries resp. accumulators into the battery compartment with the correct polarity according to the imprinted positioning diagram. 4. Close the cover. 6.18.3 Power supply unit delivered with the system The intended use of the power supply unit delivered with the system is to charge the accumulators inside the EDS190P. The charge status of the accumulators is indicated on the display of the EDS190P. 50 TGH1420en/12.2011

7. Technical data 7.1 Technical data of the EDS309... system The technical data indicated in this chapter apply to the components PGH18..., EDS190P, AGE185. Environment / EMC EMC...IEC 61326 Ambient temperature, operation...-10 C + 55 C Classification of climatic conditions acc. to IEC 60721: Stationary use (IEC 60721-3-3)... 3K5 (except condensation and formation of ice) Transport (IEC 60721-3-2)... 2K3 (except condensation and formation of ice) Storage (IEC 60721-3-1)... 1K4 (except condensation and formation of ice) Classification of mechanical conditions acc. to IEC 60721: Stationary use (IEC 60721-3-3)...3M4 Transport (IEC 60721-3-2)... 2M2 Long-time storage (IEC 60721-3-1)... 1M3 General data Operating mode... continuous operation Position of normal use... any Weight approx.... 7000 g (8500 g including PSA3165) 7.2 Technical data PGH18... Insulation coordination acc. to IEC 60664-1 / IEC 60664-3 Rated insulation voltage... AC 500 V Rated impulse voltage/pollution degree... 4 kv/3 Nominal system voltage U n PGH185...3AC/AC 42...460 Hz 20...575 V, DC 20...504 V PGH183... AC 42...460 Hz 20...265 V, DC 20...308 V PGH186... 3AC/AC 42...460 Hz 0...575 V, DC 0...504 V Supply voltage Supply voltage U S...AC 50...60 Hz 230 V Operating range of U s... 0.85 1.15 x U s Supply voltage U S version -13...AC 50...60 Hz 90 132 V PGH 183, PGH 185: Power consumption... 3 VA PGH 186: Power consumption... 6 VA Test current PGH185/186 Max. test current, selectable...10 / 25 ma PGH183 Max. test current, selectable...1 / 2.5 ma PGH183/185/186 Test cycle...2 s Idle time...4 s TGH1420en/12.2011 51

Technical data Test voltage PGH186...DC 50 V General data Degree of protection DIN EN 60529 (VDE 0470-1)... IP40 Enclosure material...abs plastic Flammability class...ul94v-0 Weight...< 700 g 7.3 Technical data EDS190P ( )* = Factory settings Insulation coordination acc. to IEC 60664-1 / IEC 60664-3 Rated insulation voltage... 50 V Rated impulse voltage/pollution degree...0.8 kv / III Supply voltage Supply voltage U S... DC 6 V +/- 10 %, external power supply unit Batteries...3 x LR6 AA 1.5 V Accumulators... 3 x NiMh 2000 mah Size... AA R6 Power consumption... 0.5 W Hours of operation (without display illumination)... 60 h Measuring circuit insulation fault location Nominal system voltage... when the conductors are uninsulated, including measuring clamp up to 600 V Rated frequency... DC, 42 2000 Hz Main circuit (I Tmax = 50 ma): Measuring clamps...psa3020, PSA3052, PSA3165 Response sensitivity I Δs adjustable...2 10 ma (5 ma)* Operating uncertainty... ±30 % / ±2 ma of the reference value Control circuit: (I Tmax = 5 ma) Measuring clamps...psa3320, PSA3352 Response sensitivity I Δs adjustable... 200 1 000 μa (500 μa)* Operating uncertainty... ±30 % / ± 0.1 ma of the reference value Measuring circuit residual current with measuring clamps...psa3020, PSA3052, PSA3165 Measuring range... 5 ma 10 A (crest factor up to 3) Response sensitivity I Δn adjustable... 10 ma 10 A (100 ma)* Measuring clamps...psa3320, PSA3352 Measuring range... 2 ma 2 A (crest factor up to 3) Response sensitivity I Δn adjustable... 5 ma 1 A (100 ma)* Frequency range...42 2000 Hz Operating uncertainty... 0-35% Hysteresis...20 % Harmonics, adjustable... 2.-9. harmonic component Inputs Type of connection measuring clamp... BNC plug Power supply unit...dc 6 V Display LCD...3 x 16 characters, selectable illumination LED...Alarm Operating uncertainty... ±17,5% 52 TGH1420en/12.2011

Technical data General data Degree of protection, internal components DIN EN 60529 (VDE 0470-1)... IP40 Protection class acc. to IEC 60947-1, DIN EN 60947-1 (VDE 0660-100)... Class III Enclosure material... ABS plastic Flammability class...ul94v-0 Operating manual... TGH1420 Weight...< 400 g Software version... D316 V1.0 Dimensions WxHxD:... 84x197x30 mm 7.4 Technical data measuring clamps Electrical safety Standard... IEC 61010-2-030:2004-05-01 Pollution degree... 2 Category... III Operating voltage...600 V Nominal insulation voltage... AC 600 V CAT III resp. AC 300 V CAT IV General data Degree of protection, internal components DIN EN 60529 (VDE 0470-1)... IP40 Protection class acc. to IEC 60947-1, DIN EN 60947-1 (VDE 0660-100)... Class III Test port... BNC plug Dimensions PSA3052/3352... 216 x 111 x 45 mm Dimensions PSA3020/3320...135 x 65 x 30 mm Dimensions PSA3165... 285 x 179 x 45 mm permissible cable diameter PSA3052/3352... 52 mm permissible cable diameter PSA3020 /3320... 20 mm permissible cable diameter PSA3165... 115 mm Weight PSA3052/3352...approx. 700 g Weight PSA3020/3320...approx. 300 g Weight PSA3165...approx. 1300 g 7.5 Technical data AGE185 Insulation coordination acc. to IEC 60664-1 Rated insulation voltage... AC 1000 V Rated impulse voltage/pollution degree...4 kv / III Nominal system voltage U n...3ac/ac 42...460 Hz, 500...790 V, DC 400...960 V General data Degree of protection, internal components DIN EN 60529 (VDE 0470-1)... IP30 Type of connection/cable:... Safety plug with green-yellow connecting wire 1 mm 2 Weight...< 200 g Dimensions WxHxD:... 88.5x42x21 mm TGH1420en/12.2011 53

Technical data 7.6 Dimension diagrams All dimensions are given in mm Aluminium case 430 145 155 310 340 AGE185 ca. 1950 88.5 ca. 450 21 42 54 TGH1420en/12.2011

Technical data 7.7 Standards Observe the applicable national and international standards. The EDS309... series meets the requirements of the following equipment standards: IEC 60364-4-41, modified Low-voltage electrical installations - Part 4-41: Protection for safety - Protection against electric shock IEC 61557-9 Electrical safety in low voltage distribution systems up to 1000 V a.c. and 1500 V d.c. - Equipment for testing, measuring or monitoring of protective measures - Part 9: Equipment for insulation fault location in IT systems IEC 61010-1 Safety requirements for electrical equipment for measurement, control, and laboratory use - Part 1: General requirements. TGH1420en/12.2011 55

Technical data 7.8 Ordering information Type Scope of delivery Supply voltage Nominal voltage Art. No.. Insulation fault evaluator Insulation fault test device Measuring clamp 20 mm Measuring clamp 52 mm EDS3090 EDS190P PSA3020 PSA3052 B91082026 AC 42...460 Hz, 20...575 V EDS3090PG EDS190P PGH185 PSA3020 PSA3052 AC 50...60 Hz, 230 V B91082021 and DC 20...504 V EDS3090PG-13 EDS190P PGH185-13 PSA3020 PSA3052 AC 50...60 Hz, 90 132 V B91082022 EDS3091 EDS190P PSA3320 PSA3352 B91082027 AC 42...460 Hz, 20...265 V EDS3091PG EDS190P PGH183 PSA3320 PSA3352 AC 50...60 Hz, 230 V B91082023 and DC 20...308 V EDS3091PG-13 EDS190P PGH183-13 PSA3320 PSA3352 AC 50...60 Hz, 90 132 V B91082024 EDS3092PG EDS190P AC 42...460 Hz, 20...265 V PGH183 PSA3320 PSA3352 AC 50...60 Hz, 230 V and DC 20...308 V AC 42...460 Hz, 20...575 V PGH185 PSA3020 PSA3052 AC 50...60 Hz, 230 V and DC 20...504 V B91082030 EDS3096PG EDS190P PGH186 PSA3020 PSA3052 AC 50...60 Hz, 230 V AC 42...460 Hz, 0...575 V B91082025 EDS3096PG-13 EDS190P PGH186-13 PSA3020 PSA3052 AC 50...60 Hz, 90 132 V and DC 0...504 V B91082029 Optional Accessories PSA3165 Measuring clamp 115 mm for EDS3090... and EDS3096 B980852 AGE185 Coupling device to extend the nominal voltage range of the PGH185/186 AC 42...460 Hz, 500...790 V, DC 400...960 V B980305 EDS165-SET Accessories for fault location in diode-decoupled systems B91082007 56 TGH1420en/12.2011

Technical data 7.9 List of components Components EDS309... PGH18... with Accessories for Measuring clamps EDS190P with Accessories EDS190P-Set, optional Measuring clamp 115 mm, optional Measuring clamp 52 mm Measuring clamp 20 mm Coupling device, optional Safety claw grip, green/yellow Safety claw grip, black Safety measuring cable, green/yellow Safety measuring cable, black Supply cable for PGH18... Insulation fault test device Power supply unit for EDS190P Adapter BNC/4mm plug -> Measuring CT Clamping plug for 4 mm Insulation fault evaluator Operating manual TGH1420 Aluminium case with carrying strap Device type EDS3090 1 1 EDS190P 1 1 1 PSA3020 PSA3052 PSA3165 1 EDS3090PG 1 1 EDS190P 1 1 1 PGH185 1 3 1 3 1 AGE185 PSA3020 PSA3052 PSA3165 1 EDS3090PG-13 1 1 EDS190P 1 1 1 PGH185-13 1 3 1 3 1 AGE185 PSA3020 PSA3052 PSA3165 1 EDS3091 1 1 EDS190P 1 1 1 PSA3320 PSA3352 1 EDS3091PG 1 1 EDS190P 1 1 1 PGH183 1 3 1 3 1 PSA3320 PSA3352 1 EDS3091PG-13 1 1 EDS190P 1 1 1 PGH183-13 1 3 1 3 1 PSA3320 PSA3352 1 1 PSA3352 PSA3052 PSA3320 PSA3020 2 2 6 2 6 PGH183 PGH185 1 EDS3092PG 1 1 EDS190P 1 1 EDS3096PG 1 1 EDS190P 1 1 1 PGH186 1 3 1 3 1 AGE185 PSA3020 PSA3052 PSA3165 1 EDS3096PG-13 1 1 EDS190P 1 1 1 PGH186-13 1 3 1 3 1 AGE185 PSA3020 PSA3052 PSA3165 1 TGH1420en/12.2011 57

Technical data 58 TGH1420en/12.2011

8. Frequently asked questions The Isometer indicates an insulation fault that cannot be localised with the EDS 309... What could be the cause? Check whether there are sub-distributions in the IT system being checked which are earthed. All outgoing distributions are to be checked for unwanted connection to earth. Also the N conductor of the transformer supplying the IT system must not be connected to earth. There is possibly no test current available. Check the earth connection of the test current generator PGH18..., IRDH575 for correct connection. The PE conductor has unintentionally been routed through the measuring clamp or the measuring current transformer. EDS190P outputs the message "Fault. What is the reason for this fault? Frequency converters or other disturbing loads may exist in the system being checked. The menu item settings /I Δs /U/converters in the menu of the EDS190P has to be activated with yes. Galvanic connections exist between different sub-distributions downstream of the measuring clamps in the direction to the loads. The location of the insulation fault may be upstream the measuring point of the measuring clamp or the measuring current transformer. EDS190P displays the fault message "No CT connected. What could be the cause? There is no measuring clamp connected or the measuring clamp is defective. A measuring clamp or a measuring current transformer of the wrong type has been connected to the EDS190P, see table on page 31. EDS190P displays the fault message "Short circuit CT. What could be the cause? The measuring clamp is defective. A measuring clamp or a measuring current transformer of the wrong type has been connected to the EDS190P, see table on page 31. In the EDS mode (I Δs ), the EDS190P displays the fault message "I Δn > 1 A resp. "I Δn > 10 A. What could be the cause for these high currents? Due to a low-resistance insulation fault, an excessively high residual current flows through the measuring clamp or the measuring current transformer. Due to the parallel connection of several insulation faults an excessively high residual current flows through the measuring clamp or the measuring current transformer. Strong magnetic fields in the vicinity of the measuring clamp generate a measuring signal in the measuring clamp or in the measuring current transformer. A measuring error will occur unless all active conductors are enclosed with the measuring clamp. The LC display shows undefined indications. What could be the cause? The installed batteries or accumulators are almost used up. TGH1420en/12.2011 59

Frequently asked questions 60 TGH1420en/12.2011

INDEX A Accessories - optional 13 Accumulator - replace 50 Alarm is output acoustically 34 Alarm LED 31 Alarm output activated via LED 34 Alarms in the EDS or RCM mode 35 Application - primary 40 B Button to select the measuring clamp 31 C Characteristic curves 23 Charge status of the accumulators 34 Clear fault memory 32 Commissioning 27 conductors - shielded 15 Connection 28 Connection for external power supply unit 31 Converters in the system 36, 37 Coupling 40 Coupling device AGE185 49 D Decoupling the insulation monitoring device 27 Device resp.measuring errors 36 Device-specific safety information 9 Dimension diagrams 54 Diode decoupled IT system 44 Display elements and their meaning 34 Display illumination 32 Down key 32 E EDS mode 14 EDS190P - Operating elements 31 F Factory settings 36 Fault 36 Fault current circuit 15 Fault memory M is activated 34 Frequently asked questions - 59 H Hold function activated 34 HOLD key 32 I Indication of the test current pulse 34 Insulation fault evaluator 14 Intended use 9 L Leakage currents 17 List of components 57 M measuring clamps - using 40 Measuring current transformer - commercially available 13 Menu structure 37 N Navigation in the EDS190P menu 37 O On/Off switching 32 Operating mode button 31 Operating principle 15 Ordering information including accessories 56 P Permanently installed EDS system 42 persons 10 PGH18... - Operating elements 30 Power supply of the EDS190P 50 Practical use 40 Progress bar showing the measurement progress in the EDS mode 34 Q Querying the current response values 31 Querying the device type 31 Querying the software version 31 R RCM mode - Function 18 Reset button 32 Residual current evaluator 14 Residual currents - Path 17 Response characteristic curves for control circuits 25 Response characteristic curves for main circuits 23 S Saving the measured value with HOLD 32 Selected measuring current transformer 34 Selection of the measuring current transformer 31 Selection of the measuring sensitivity 34 Selection of the operating mode 31 SPC 22 Standard display in the EDS mode 35 Standard display of the EDS190P 35 Standards 55 Starting the menu mode 32 symmetrical - insulation fault 21 System components 7, 11 Systems - deenergised 27 T Technical data 51 Test current 15 Test current limit 22 Test cycle 16 TGH1420en/12.2011 61

INDEX U Up key 32 V View harmonics 35, 39 62 TGH1420en/12.2011

Dipl.-Ing. W. Bender GmbH & Co. KG Londorfer Str. 65 35305 Grünberg Germany Postfach 1161 35301 Grünberg Germany Tel.: +49 6401 807-0 Fax: +49 6401 807-259 E-Mail: info@bender-de.com Web: http://www.bender-de.com