STANDARD OPEN PATIO COVER



Similar documents
TYPICAL PATIO COVERS 111

Attached/Detached Patio Cover/Carport

POST AND FRAME STRUCTURES (Pole Barns)

Residential Decks. Planning and Development Services Department

Residential Deck Safety, Construction, and Repair

This handout is a guide only and does not contain all of the requirements of the Minnesota State Building Code or city ordinances.

COMMONLY USED RESIDENTIAL BUILDING CODES

Uncovered Decks & Porches

4. ANCHOR BOLTS AND STRAPS a. ½" anchor bolts shall be embedded 7" into concrete a maximum of 6' on center and 12" from corners and ends of plates.

Development Services Department Building Permit & Inspection Services Shed and Garage Construction Guide for Detached and Semi-Detached Dwellings

The better way to build TM. Installation Manual. FOUNDATION SIPs & FROST WALLS SIPs

Patio Covers / Carports

Asphalt Shingle Application Requirements

HURRICANE MITIGATION RETROFITS FOR EXISTING SITE-BUILT SINGLE FAMILY RESIDENTIAL STRUCTURES

Wood Decks Zoning and construction requirements for open non-sheltered wood decks for residential dwellings.

March 14, Installation of Bay, Bow and Garden Windows

Custom 30 x 20-8 Garage Plan Plan #g233 By SDS-CAD Specialized Design Systems

1. Concrete: T W L / 27 = Concrete C.Y. Multiply Feet Thickness x Feet Width x Feet Length / 27 = Cubic Yards.

Timber Decks. Technical Note. March 2007

1/2" CDX PLY W/ 6"/ 6"/ 12" 2x ROOF 16"OC W/ R-30 BATT. INSUL. (COMMON NAILS)

Mark Cramer Inspection Services, Inc.

6 RETROFITTING POST & PIER HOUSES

Post and Beam Construction

Chapter 3 Pre-Installation, Foundations and Piers

RESIDENTIAL FOUNDATION GUIDELINE Johnson County, KS

Detached accessory structures that contain no conditioned floor area are exempt.

Building Information Packet

REQUIREMENTS FOR SUBMITTING PLANS FOR NEW CONSTRUCTION

Page & Turnbull imagining change in historic environments through design, research, and technology

Final inspections are completed by site visit only. Access to fenced yards shall be planned.

Fig. 2 WALL-TO-WALL PANEL CONNECTIONS CORNER WALL CONNECTION

ONE-STOP S PERMIT INFORMATION PACKAGE FOR RESIDENTIAL PROJECTS

Section A Roof Truss

Free 12 x 8 Shed Plan With Illustrations, Blueprints & Step By Step Details

Superform Products Ltd.

INFORMATION BULLETIN NO.

Formwork for Concrete

RESIDENTIAL ROOFING & RE-ROOFING, ROOF VENTILATION AND ROOF SHEATHING REQUIREMENTS MICHIGAN RESIDENTIAL CODE 2000

How to secure your property after a disaster

CITY OF BERKELEY BUILDING PERMIT DETAILED CHECKLIST

Owner's Manual & Assembly Instructions

INFORMATION BULLETIN NO.

Sample Drawing Package for One and Two Family Dwelling Applications

Solar Water Heating and Solar Electric Generators Installed on One or Two Family Dwellings

STRUCTURAL ASSESSMENT REPORT BOLINAS MARINE STATION - BOLINAS, CALIFORNIA

MUNICODE SERVICES LTD.

SUPER SHED. Indoor shelter for your outdoor tools.

RESIDENTIAL WOOD DECKS

NCMA TEK CONCRETE MASONRY FOUNDATION WALL DETAILS. TEK 5-3A Details (2003)

Protecting Your Home from Wind Damage

Ceiling Mounted Folding Attic Ladders Installation Instructions

Additions and Alterations

AMERICAN GOTHIC PLAYHOUSE

Featuring TJ Rim Board and TimberStrand LSL

Best Barns USA Assembly Book

2014 FLORIDA BUILDING CODE

SECTION COLD-FORMED METAL DECK FRAMING Elevations Steel Deck Framing by Trex

Chapter 6 ROOF-CEILING SYSTEMS

SINGLE-FAMILY EARTHQUAKE (SEISMIC) RETROFITS

1997 Uniform Administrative Code Amendment for Earthen Material and Straw Bale Structures Tucson/Pima County, Arizona

NAVAJO COUNTY ADDENDA & ADDITIONS TO THE INTERNATIONAL BUILDING CODES. Public Works/Planning & Zoning Building & Safety AMENDED ( )

Chapter 36 - STRAW BALE CONSTRUCTION SECTION PURPOSE. SECTION SCOPE. SECTION DEFINITIONS.

FLAT ROOF BOX SPAN CARPORTS

Residential Building Permit Process

PERGOLAS AND CARPORTS

BUILDING SAFETY UNIT

Residential Building Permits

Discipline: Structural Issued

Development Services City of Lawrence, KS

Preformed Metal Roofing and Siding

Owner's Manual & Assembly Instructions

LP OSB Sheathing & Structural 1 Sheathing

Elevating Your House. Introduction CHAPTER 5

When is a Permit Required? What Types of Permits are Required? The most common types of projects that require permits are:

Basic Requirements for Residential Plan Review _

Wood Projects Outdoors. Post Hole Specifications. Deck Span Tables. Eakes.com

RESIDENTIAL WOOD DECK CONSTRUCTION GUIDE

Owner's Manual & Assembly Instructions

CONSTRUCTION DETAILS & LOAD DESIGN CHARTS

A Guide to Detached Residential Garages and Residential Workshops (based on 2006 BCBC)

Certification: Building Plans Examiner. Exam ID: B3

STRUCTURAL CONCEPT FOR LIGHT GAUGE STEEL FRAME SYSTEM

Chapter 10 - Scaffolding Systems

International Greenhouse Company

General (1) This Section applies to the design and construction of interior and exterior stairs, steps, ramps, railings and guards.

Site Development Information Worksheet for single family residential development

Wisconsin Building Products Evaluation

Guidelines for Earthquake Bracing of Residential Water Heaters

RESIDENTIAL PLUMBING ALTERATIONS PERMIT REQUIREMENTS

ATLANTA MODEL SPECIFICATIONS

MANUFACTURED HOUSING USED AS DWELLINGS

ISO Types 1-6: Construction Code Descriptions

Residential Building Permits Information

8/18/14. Introduction to. Framing. Terminology and Concepts

COLORADO MODEL. 35 x 65 SPECIFICATIONS

Breakaway Walls

Residential Foundations and Basements

Building Construction. Structural Systems 1. Load-bearing wall construction 2. Skeleton framing 3. Combination of the two

How To Repair A House

Policy on Water Heater Installations Policy No. UPC Effective: September 1, 1995 Revised: February 10, 1996

Transcription:

STANDARD OPEN PATIO COVER BUILDING & SAFETY DIVISION 201 E. LA HABRA BLVD. LA HABRA, CA 90631 62-90-9710 Call Before You Dig 1-800-227-2600

PLEASE NOTE: This information Bulletin is made available to assist you in preparing for obtaining permits. DEFINITION Patio covers are one-story, roofed structures not more than 12 feet above grade and used only for recreational or outdoor living purposes, not as carports, garages, storage rooms, or habitable rooms. Patio covers must be open on two or more sides for not less than 6% of the wall area below a minimum of 6 8 of each open wall, measured from the floor. The open sides must not be covered with any permanent materials which obstruct the free passage of light and air, except insect screening, or approved, translucent or transparent plastic, not more than.12 inch (3.2 mm), in thickness, glass conforming to the provisions of chapter 2 (tempered) or any combination of these. If two sides are open, the open sides may be partially enclosed by solid walls which do not exceed 30 inches in height above the floor, in addition to the screening (see drawings in this information bulletin). When required windows from adjoining rooms open into a patio cover, however, open area equivalent to the requirements of Appendix I Section 102 of the California Building Code apply. Patio covers may be attached or detached, and permitted only as accessory to single-family dwellings or to individual dwelling units in multi-dwelling-unit buildings. Patio covers cannot be used as carports, garages, habitable rooms or storage structures. Detached patio covers must be located a minimum of 10 from the main structure. Other provisions of the zoning code relating to minimum open areas and separation from the property line may apply. Please contact the Planning and Building & Safety Divisions for details related to your specific site plan. CONCRETE MIX The concrete mix for footings must meet the strength of Fc = 2000 psi minimum, or the following: 1 part Portland cement 2 ½ parts sand 3 ½ parts ¾ inch maximum size gravel Not more than 7 gallons of water per sack of cement. LUMBER Lumber shall be Douglas Fir / Larch No. 2 or better. All lumber must be grade marked. POST ANCHORAGE AND BRACING The details shown on this sheet have been approved by the City of La Habra, Building and Safety Department. Posts must be anchored at the lower and by any of the methods noted. They must be braced to the upper end using any of the optional methods shown. Manufacturer s installation instructions must be followed for installation of all connector and anchorage hardware. Decorative-type bracing may be substituted for the above if the same amount of structural bracing is realized. When the load on any single supporting post does not exceed 70 pounds per post, a minimum 3 ½ thick concrete slab on grade may be substituted for the pad footings shown on the typical framing details: Post anchorage to slabs must be the same as to footings. LEDGER TO HOUSE ATTACHMENT When it is desired to connect and support one side of the structure by attaching it directly to the house, the rafter spans and main beam sizes will be as shown in the table. However, the main beam may be replaced on the side attached to the house with a ledger the same size as the rafters and fastened to the studs with 3/8 X lag screws, spaced at 16 on-center. Attachment to existing house rafters is achieved with optional method shown (See Details A & B of Sheet ). ROOF COVERING If covered with nominal one-inch roof sheathing, the roof must have rafters spaced not more than 32 center to center. Maximum spacing for rafters supporting plywood decks shall be in accordance with spans shown on the structural panel. When used, plastic roof coverings must be installed according to manufacturer s recommendations and the corrugations should be placed perpendicular to and across the supports. All roof coverings (including plastic) must be/minimum class B rated for flame spread. Roof slope must be specified on plans. Roof Live Load = 10 psi, minimum. Roof Dead Load = 7 psi, minimum, or actual weight of materials. NOTE: BUILDERS OF STEEL AND ALUMINUM THE CITY OF LA HABRA REQUIRES TRACK AND LEDGER INSPECTIONS. 1

***NOT TO SCALE*** DIRECTIONS 1. Do not use pencil or red ink. 2. If framing plan is different from shown in this form, use an additional page (or pages) to show the framing plan. 3. Submit the following a. Three copies of the site plan. (Standard forms are available see page 7.) b. Three copies of this form. Complete both sides. c. A Building Permit application form. GUIDELINES FOR PATIO CONSTRUCTION (Choose one that best fits your condition) Single Family Zero Lot Line Condominium* Town House* *REQUIRES HOA APPROVAL Header Span Table A Header Span Table A Rafter Spacing Table B D C & D A & B Rafter Span Table B Header SECTION Header Ledger Rafter Post 6 8 Min A, B & C Existing House FRAMING PLAN PATIO COVER REQUIREMENTS 1. HEADER: Header shall be Single Header Double Header 2. JOISTS: Joists shall be X at on center. Single Joists Double Joists 3. ROOF SHEATHING: Sheathing shall be self spaced.. LEDGER: Ledger shall be a X mounted on existing wall with 3/8 X lag bolts at 16 on center. (See Detail A of Sheet ). FASCIA Existing fascias, if used as a ledger, must be attached to the existing rafters with metal framing anchors on each side of each rafter. (See Detail B of Sheet ) 2

Rafter TABLE A MINIMUM HEADER SIZES POST SPACING (SEE FRAMING PLAN) Span 6-0 8-0 10-0 12-0 1-0 16-0 18-0 20-0 -0 x x6 x6 x6 x8 x8 x8 x10 6-0 x x6 x6 x6 x8 x8 x10 x10 8-0 x x6 x6 x6 x8 x10 x10 x12 10-0 x6 x6 x8 x8 x8 x10 x10 x12 12-0 x6 x6 x8 x8 x10 x10 x12 x12 1-0 x8 x8 x8 x10 x10 x10 x12 x1 16-0 x8 x8 x10 x10 x10 x10 x12 x1 18-0 x10 x10 x10 x10 x12 x12 x1 x1 20-0 x10 x10 x12 x12 x12 x12 x1 x1 TABLE B Rafter MINIMUM RAFTER SIZES RAFTER SPACING (Center to Center) Span 12 16 2 32 6-0 2 x 2 x 2 x 2 x 7-0 2 x 2 x 2 x 2 x 8-0 2 x 2 x 2 x 2 x 9-0 2 x 2 x 2 x 2 x 10-0 2 x 2 x 2 x 2 x6 11-0 2 x 2 x 2 x6 2 x6 12-0 2 x 2 x6 2 x6 2 x6 13-0 2 x6 2 x6 2 x6 2 x6 1-0 2 x6 2 x6 2 x6 2 x8 1-0 2 x6 2 x6 2 x6 2 x8 TABLE D ROOF SHEATHING 16-0 2 x6 2 x6 2 x8 2 x8 17-0 2 x6 2 x6 2 x8 2 x8 2 x 2 Self Spaced Spans 6-0 11-0 2 x Self Spaced Spans On Edge 18-0 2 x6 2 x6 2 x8 2 x10 19-0 2 x8 2 x8 2 x8 2 x10 20-0 2 x8 2 x8 2 x8 2 x10 Post TABLE C MINIMUM SQUARE FOOTING SIZES RAFTER SPAN (SEE CROSS SECTION) NOTES: *See paragraph on post anchorage **After prolonged periods of time 2 rafters spanning more than 8 feet, minimum, deflect permanently and give an objectionable appearance. It is, therefore, recommended that for rafter spans exceeding 8 feet, a minimum rafter size of 2 x 6 be used. Spacing 6-0 8-0 10-0 12-0 1-0 16-0 18-0 20-0 -0 12 sq 12 sq 12 sq 12 sq 12 sq 12 sq 1 sq 1 sq 6-0 12 sq 12 sq 1 sq 1 sq 1 sq 16 sq 16 sq 16 sq 8-0 1 sq 1 sq 1 sq 16 sq 16 sq 18 sq 18 sq 20 sq 10-0 1 sq 16 sq 16 sq 18 sq 18 sq 20 sq 20 sq 22 sq 12-0 16 sq 16 sq 18 sq 20 sq 20 sq 22 sq 22 sq 2 sq 1-0 16 sq 18 sq 20 sq 20 sq 22 sq 22 sq 2 sq 2 sq 16-0 18 sq 20 sq 20 sq 22 sq 2 sq 2 sq 27 sq 27 sq 18-0 20 sq 20 sq 22 sq 2 sq 2 sq 27 sq 27 sq 30 sq 20-0 20 sq 22 sq 2 sq 2 sq 27 sq 27 sq 30 sq 30 sq 3

X Post X Post (Not naturally durable or pressure treated.) Adjustable Post Base (AB ) 8 Minimum or Naturally durable species or pressure treated. Minimum 3 ½ Concrete Slab Adjustable Post Base (CB ) 1 Minimum Standoff - Per manufacturer s instructions dry pack with concrete after post installation. MIN. Wedge anchor, epoxy anchors, or other approved devices 8 Min. A SLAB FOOTING Min. 6 mil. (.006 inch) polyethylene sheeting, impervious moisture barrier. 12 Min. 12 Min. Table C ***NOT TO SCALE*** B PAD FOOTING x Post Column Base (CB ) W/ 2-/8 Dia. Machine Bolts Roof Sheathing See Table D: 2 X Rafter See Table B Pre-Fab Pier or Cast in place Concrete Pier 8 Min. L- Strap (OL Strap Tie) W/ ½ Dia. Machine Bolts, through bolted, with nuts and washers as required for the bolt sizes. 16 Min. Header See Table A T-Strap (or Strap Tie) W/ 6-1/2 Dia. Machine Bolts. 16 Square Minimum C PIER FOOTING D HEADER: ELEVATION

***NOT TO SCALE*** Fasteners as specified by manufacturer. Roof Sheathing See Table D Exterior Stud Wall Exterior Stucco 3/8 X Lag Bolt @ 16 o.c. 16 Max. FACE 16 Max. 1 Minimum 2 X Ledger, minimum width to match rafters. SECTION Existing Residence Roof Overhang A LEDGER DETAIL A3 on Each Side of Each Rafter Roof Sheathing See Table D See Note 1 NOTE: 1. Standard Joist Hanger.. Existing 2 X Fascia ½ Dia Machine @ 16 o.c. Rafter See Table B ***All existing structural lumber used to support the new patio cover must be structurally sound (i.e. Without termite damage, dry rot, or other decay). 2 X Ledger B EAVE CONNECTION SECTION

***NOT TO SCALE*** X False Post Roof Sheathing See Table D Continuous 2 X Blocking W/16d nails @ 8 o.c. Alternate A3 @ 2 o.c. Double 2 X Rafter See Table B 2 ½ X 6 Machine Bolts with Flat Washers Each Side Header See Table A Post Cap (PC ) 2 X Rafter See Table B X Post X Post (Where it Occurs) C HEADER DETAIL D HEADER DETAIL PLEASE PROVIDE THREE SETS OF SITE PLAN AND CONSTRUCTION DETAILS FOR REVIEW AND APPROVAL. 6

PLOT PLAN P.L. feet 6 Proposed PATIO COVER 6 P.L. feet P.L. feet EXISTING HOUSE 2 3 N STREET (NAME) SCALE: = 1 INSTRUCTIONS 1. Show project address, owners name, north arrow and scale 2. Show accurate footprint of all existing and proposed structures 3. Show driveway. Show all property lines (P.L.), label each and properly dimension. Show dimensions of proposed structures(s) 6. Show setbacks from property lines to proposed structure(s) Notes: Owner: Address: City: State: Zip Code: 1. Have correct legal description and address of property. 2. Note adjoining streets or alleys and width of curb cuts. 3. Note location of each auto parking spaces.. North arrow should be correctly placed.. Draw completely dimensioned lot plan. 7