Water Tank Level Monitor



Similar documents
RADIO CONTROLLED DIGITAL CLOCK MODELS / 88906

WIRELESS WEATHER STATION Model USER'S INSTRUCTIONS

ATOMIC CLOCK WITH OUTDOOR WIRELESS TEMPERATURE

MAKING MODERN LIVING POSSIBLE. living connect. Installation and User Guide. Danfoss heating

MAKING MODERN LIVING POSSIBLE. living connect. Installation and User Guide. Danfoss Heating Solutions

Digital Wireless Rain Gauge & Thermometer

Model: Manual DC: WIRELESS COLOR FORECAST STATION

Wireless Home Security Alarm System AM 500

The Weather Station. Hanging Hole. LCD Display Battery Cover. Function Keys. Detachable Stand

ATOMIC CLOCK WITH MOON PHASE. MODEL Instruction Manual

IN-OUT Thermometer with Cable Free Sensor and Clock

WIRELESS MULTI-ZONE DIGITAL WEATHER CENTER. Model No User s Manual

Please read the operating instructions carefully to familiarize yourself with the features and modes of operation before using the instrument.

WIRELESS FORECAST STATION

WIRELESS 433 MHz TEMPERATURE STATION Instruction Manual Cat. No

Model: v2 Quick Setup Guide DC: Atomic Projection Alarm with Indoor and Outdoor Temperature

WEATHER STATION Instruction Manual Cat. No IT

User Manual of WT 493

WIRELESS WEATHER STATION

Radio-Controlled Projection Clock with Indoor Temperature

ST815 Illumination Sensor with LCD

LCD Display. Function keys. Stand. Adapter socket

MEMO ALARM CLOCK Operating Manual

PROFESSIONAL WEATHER CENTER WS-1510-IT Instruction Manual. PROFESSIONAL WEATHER CENTER WS-1510-IT Instruction Manual. Table of Contents FEATURES:

FAMILY WEATHER STATION Instruction Manual

TOUCH SCREEN WEATHER STATION MODEL WS Operation Manual

Atomic Projection Alarm with Indoor and Outdoor Temperature

Estação Meteorológica sem fio VEC-STA-003

GSM HOME SECURITY SYSTEM

ATOMIC CLOCK WITH OUTDOOR WIRELESS TEMPERATURE AND MOON PHASE MODEL Instruction Manual

WIRELESS ALARM SYSTEM WITH TELEPHONE AUTO DIALER

WIRELESS ALARM SYSTEM WITH TELEPHONE AUTO DIALER

WS-9005TWC 915MHz WIRELESS RAIN GAUGE INSTRUCTION MANUAL

Atomic Alarm Clock Instruction Manual

WEATHER STATION Instruction Manual Cat. No IT

Solar Weather Station Model: BAR806 / BAR806A

User Guide. Model: MAS-WA-SYS

GSM Alarm System User Manual

WIRELESS 433 MHz WEATHER CLOCK Instruction Manual

User's Guide. Pinless Moisture Meter. Model MO257

PR-2500 Portable Receiver. Owner s Manual

WIRELESS 868 MHz WEATHER STATION Instruction Manual

4-Channel Thermometer / Datalogger

Wireless Indoor/ Outdoor Thermometer

MOBILE CALL GSM alarm system

T7400. Guest Paging System. Long Range Systems, Inc Chartwell Dr., Dallas, TX V6.21 and later

TOUCH SCREEN WEATHER STATION (WIND AND AIR PRESSURE) WH-1080PC. Operation Manual

Your Simple Guide to Battery. Replacement. Customer Care:

Installation. Ventus Wireless Weather station. Owner s Manual

1. Overview. WPT Wireless Range Tester Kit User Manual Doc No Rev Components Prerequisites for Site Survey

Get Support:

OPUS WIRELESS WEATHER STATION Instructions Manual Cat. Nr IT

PiSector Home security systems

HWS100 Wireless Home Security System

REMOTE TERMOMETER TE 219 LED USER MANUAL

FSLIMRF

New GSM Alarm System. User s Manual. Profile For a better understanding of this product, please read this user manual thoroughly before using it.

User Manual. Humidity-Temperature Chart Recorder. Model RH520

User Guide. Temperature and Humidity Datalogger. Model 42280

Wireless Home Security System Product Manual (Model #80355)

WS1093 PROFESSIONAL WIRELESS WEATHER STATION WITH TOUCHSCREEN AND USB UPLOAD

INSTALLING A/C ADAPTER

User's Guide. Digital Psychrometer. Model RH390. F C WBT Dew Point MAX MIN

Stove Guard Kit User Manual

Operation Manual Professional Remote Weather Station

Alarm Security Kit - NVR

WS 2810U Wireless Professional Weather Center

Six-defense zone Display Alarm System. User Manual

BIGPOND ULTIMATE MOBILE BROADBAND WI-FI QUICK START GUIDE

Laser Distance Meter Laser-Distanzmesser Laser distance-mètre Metro di distanza laser Medidor Láser de Distancia User Manual

SP1790JK 900MHz Wireless Indoor/Outdoor Speakers. User Manual INTRODUCTION FEATURES IMPORTANT SAFETY INFORMATION

DCMT-2500 Wireless Transmitter. Owner s Manual

Drayton Digistat +2RF/+3RF

Leaf River Outdoor Products Vibrashine, Inc. P.O. Box 557 Taylorsville, MS (601) FAX (601)

Alarm Clock USER GUIDE

PROFESSIONAL WEATHER STATION (WIND AND AIR PRESSURE) Operation Manual

Sensi TM. Wi-Fi Programmable Thermostat MANUAL OPERATION. Version: March Emerson Electric Co. All rights reserved.

MOBILE CALL GSM Alarm System User s Manual

THE NEW GENERATION IN TECHNOLOGY. NI-3103A Alarm Clock w/fm Radio ipod & iphone Docking. Operating Instructions

REMOTE CONTROL MANUAL

RF Projection Barometer With Remote Thermo Sensor

Rain+Birdt. Simple To Set Timer (SST) Setup & Operation Instructions. English RAIN BIRD ( ) or visit

CM921 - User Guide. Description. Features. 1 day Wireless Programmable Room Thermostat with LoT technology WHAT IS A PROGRAMMABLE ROOM THERMOSTAT?

Home Security Alarm System

Single Day Alarm Clock with. Bluetooth and USB Play-through

RDJ10RF/SET. Wireless room temperature controller with 24-hour time switch and LCD. Programmable, for heating systems

Wireless AUTODIAL GSM SMS Home Alarm Security System 900/ 1800/ 1900Mhz(CK-GSM-9003)

INSTRUCTION MANUAL All-In-One GSM Home Alarm System SB-SP7200-GSM

HAZUBA. HAZUBA AG Rainstrasse Zuchwil T F info@hazuba.ch 06/14

WIRELESS 868 MHz WEATHER CLOCK Instruction Manual

Business/Home GSM Alarm System. Installation and User Manual

Thermometer model 00754

Important Safety Instructions

TE688W Wireless Weather Forecaster with Indoor/ Outdoor Temperature and Humidity

Intelligent GSM Auto-dial Alarm System User s Manual

DAB+ / FM Tuner Model: TU-201

Microwave Meter. Instruction Manual

LG Wireless Remote Controller

Weather Center model 00436/00634A1/00634A2/00634CA

WPR400 Wireless Portable Reader

Transcription:

Water Tank Level Monitor INSTRUCTION MANUAL MODEL NO: WTL001 Table of Contents 1. INTRODUCTION... 2 1.1 Package Contents... 2 1.2 Features... 2 2. INSTALLATION... 3 2.1 Water Tank Sensor Battery Installs... 3 2.2 Set Up Sketch... 3 2.3 Installation Notes... 4 2.4 Indoor Receiver Battery Install... 4 2.5 Initial Set Up... 4 3. OVERVIEW... 5 4. PROGRAM MODE... 6 4.1 SET TANK DEPTH... 6 4.2 SET AIR GAP... 7 4.3 SET TIME... 8 4.4 SET TEMPERATURE UNIT... 8 4.5 SET TANK LEVEL UNIT... 8 4.6 CHECK AND RESET MIN/MAX VALUE... 9 4.7 TANK LEVEL AND TANK TEMPERATURE SWITCH... 9 4.8 ALARM... 9 4.8.1 SET ALARM TIME... 9 4.8.2 SET TANK LEVEL HIGH AND LOW ALARM... 10 4.8.3 ENABLE OR DISABLE ALARM BUZZER... 10 4.8.4 EMPTY ALERT... 10 5. DEFAULT VALUE... 10 6. SPECIFICATIONS... 11 This Operation Manual is part of this product and should be kept in a safe place for future reference. It contains important notes on setup and operation.

1. INTRODUCTION Please read this instruction manual thoroughly to fully understand the correct operation of your Water Tank Level Monitor. The following user guide provides step by step instructions for installation, operation and troubleshooting. 1.1 Package Contents l 1 x Indoor receiver l 1 x Water tank transmitter Mounting screws Instruction manual 1.2 Features 12/24 hour time display Time alarm Indoor temperature Tank temperature Monitors water tank level Level displayed on a 10 element LCD bar graph for water level Records min. and max. for indoor and tank temperature/level TANK level high/low alarm mode All alarm ON/OFF option system TANK empty alert Transmitter low battery indicator Tank level updated 30 seconds or 3 minutes 2

2. INSTALLATION 2.1 Water Tank Sensor Battery Installs Note: Please note the polarity when inserting/replacing batteries in the unit, failure to do so may result in permanent damage. Use good quality alkaline batteries or rechargeable batteries. 1) Open the battery door, remove the battery box; 2) Insert 6 x AAA 1.5V alkaline batteries into the battery box, observing the correct polarity. Then put back the battery box according to the marking direction. 2.2. Set Up Sketch The following picture illustrates transmitter installation: 1. Antenna 2. Balance bubble 3. Screw 4. Bracket 5. Sensor 6. Tank NO R(m) H3(m) 1 0.1 1 2 0.2 3 3 0.3 5 4 0.5 10 5 0.8 15 3

H3: The exact distance sensor can measure. R: The sensor from the tank wall distance. Note: the sensor from the tank wall distance will affect the measurement range and precision of depth Please pay attention to the following issues in installation: 1) The distance between transmitter bottom and highest water surface must be 0.5m (1.64ft) or more. 2) The maximum depth the unit can measure is 15m (49.2ft). 3) Observe the balance bubble on the sensor to ensure it is installed at a level horizontal position. 2.3 Examples of Wrong Installation 1 2 3 4 1) The sensor is not installed at a level horizontal position. 2) The sensor is too close to the TANK wall. 3) There are solid objects in the tank. 4) The transmitter bottom is dipped in the water (or other liquids in tank) 2.4 Indoor Receiver Battery Installation 2.5 FRONT VIEW BACK VIEW Open the base station s battery cover located at the back of the unit and insert 4

2 x AA, 1.5V alkaline batteries into the battery compartment and close the battery cover. 2.5 Initial Set up First, insert the batteries into the wireless outdoor transmitter (6 x AAA) and then insert batteries immediately into the LCD display monitor (2 x AA). Once the batteries are in place, all segments of the LCD will light up briefly. 3. OVERVIEW The following illustration shows a normal LCD display for description purposes only 1. Value display area (Fig. 1 & 2) Fig.1 2. Tank temperature and water level icon Fig.2 5

3. Water level unit 4. Tank temperature unit (ºC/ºF) 5. Outdoor low battery indicator 6. Alarm activation icon 7. Min. and max. indicator icon 8. Empty alert icon 9. RF signal indicator 10. Tank level high and low alarm indicator 11. Water tank depth icon 12. Time alarm indicator Fig.3 13 Time and alarm value area ( Fig 3 ) 14 Time icon 15 Indoor temperature value display area 16 Indoor temperature unit 4. PROGRAM MODE 4.1 SET TANK DEPTH When the display unit is powered up, the LCD display activates for 3 seconds and makes a Beep. The unit is now in Set Tank Depth mode and displays the tank depth value as a flashing "0.00" as well as a flashing empty tank icon (Fig.4). Fig.4 6

Press +/MAX/MIN key or -/TANK key to increase or decrease tank depth. Pressing and holding the keys will change the value at a much faster rate. Press the SET key to save the Tank Depth value. The LCD monitor now enters into Set Air Gap mode. NOTE: To record correct measurement of tank depth (see H1+H2 in sketch of 2.2 on page 3), calculate from the bottom of the tank transmitter to bottom of your tank. Distance: 0.5m (min) - 15.0m (max) or 1.64 (min) - 49.2 (max) 4.2 SET AIR GAP The monitor is now in Set Air Gap mode and displays "0.00" and full tank icon flashing(fig.5). Press +/MAX/MIN key or -/TANK key to increase or decrease air gap. Hold +/MAX/MIN key or -/TANK key to increase or decrease air gap at greater step. Press the SET key to exit depth setting Fig.5 Display of "0.00" and full tank icon flashes(fig.5). Press +/MAX/MIN key or -/TANK key to increase or decrease air gap. Pressing and holding the keys will change the value at a much faster rate. Press the SET key to save the Air Gap value. NOTE: To record correct measurement of Air Gap (see H1 in sketch of 2.2 on page 3), calculate from the bottom of the tank transmitter to the maximum fluid level of tank. Distance: 0.5m (min) - 15.0m (max) or 1.64 (min) - 49.2 (max) 7

If there s no key operation in depth setting mode for longer than 15 seconds the unit will switch to normal display mode automatically. (There will be measurement errors if the tank depth and air gap are not set correctly). If you miss this step, Tank Depth and Air Gap can be set later. In normal operation mode, press and hold SET and ALARM keys for 5 seconds to set Tank Depth and Air Gap values. The setting steps are the same as above described. 4.3 SET TIME In normal display mode press SET key for 3 seconds to enter SET mode. 12/24H: 12Hr or 24Hr will flash. Press +/MAX/MIN or -/TANK key to select 12H or 24H. Press SET key to move to hour setting. HOUR: Hour value will flash. Press +/MAX/MIN or -/TANK key to increase or decrease hour value. When hour value is set press SET key to set minute value. MINUTE: Minute value will flash. Press +/MAX/MIN or -/TANK key to increase or decrease minute value. When minute value is set press SET key to set temperature unit. 4.4 SET TEMPERATURE UNIT Temperature unit will flash. Press +/MAX/MIN or -/TANK key to select temperature unit of ºC or ºF. After temperature unit is set press SET key to set tank level unit. 4.5 SET TANK LEVEL UNIT Tank level unit will flash. Press +/MAX/MIN or -/TANK key to select water level unit of M (metre) or FEET. After tank level unit is set press SET key to exit. 8

4.6 CHECK AND RESET MIN/MAX VALUE In normal display mode press +/MAX/MIN key once to check the max value of indoor temperature and tank level or tank temperature. Press +/MAX/MIN key again to check the min value of indoor temperature and tank level or tank temperature. Press +/MAX/MIN key again to exit. In the MIN/MAX mode press SET key, the min or max icon and value will flash. Press the +/MIN/MAX key once, the displayed minimum or maximum record will be reset to current value. Press SET key to reset the next minimum or maximum record. 4.7 TANK LEVEL AND TANK TEMPERATURE SWITCH In normal display mode press -/TANK key to switch from tank level display to tank temperature display or switch from tank temperature display to tank level display. NOTE: If the tank level and tank temperature display --.--, this means the transmission signal is lost and needs to be reconnected to the LCD monitor. Press the -/TANK key for 5 seconds. The tank transmitter icon with double-ended arrow will be displayed on the LCD monitor indicating the transmitter and monitor are reconnecting. This can take up to 3 minutes before a tank reading appears. 4.8 ALARM 4.8.1 SET ALARM TIME In normal display mode press ALARM key. Previously set alarm time will display. Press SET key 3 seconds to set alarm hour. Alarm hour will flash. Press +/MAX/MIN or -/TANK key to increase or decrease alarm hour. After alarm hour is set press SET key to set alarm minute. Press +/MAX/MIN or -/TANK key to increase or decrease alarm minute. 9

During alarm hour or minute flashing press ALARM key to enable or disable time alarm. When alarm time is enabled the icon is visible. When alarm time is disabled the icon is invisible. Press SET key to confirm alarm time setting and start to set level high or low alarm. 4.8.2 SET TANK LEVEL HIGH AND LOW ALARM After finishing alarm time setting previously, now set tank level alarm value will flash. Press +/MAX/MIN or -/TANK key to increase or decrease HIGH alarm value. After tank level HIGH alarm is set press SET key to set tank level LOW alarm. Press +/MAX/MIN or -/TANK key to increase or decrease LOW alarm value. During high or low alarm value flashing press ALARM key to enable or disable water level alarm. When high or low alarm is enabled the icon is visible. When high or low alarm is disabled the icon is invisible. After tank level low alarm is set press SET key to exit. 4.8.3 ENABLE OR DISABLE ALARM BUZZER In default setting the alarm buzzer is enabled. To disable the alarm buzzer press ALARM key for 5 seconds. The alarm icon will disappear. Press ALARM key 5 seconds again to enable alarm buzzer. The alarm icon will appear. 4.8.4 EMPTY ALERT When water level is less than 20% of tank depth the icon will display. 5. DEFAULT VALUE 1. Time:0:00 23:59 (default: 0:00) 2. 12HR/24HR format:(default: 24HR) 3. Temperature unit:ºc/ºf (default: ºC) 4. Water level:metre/feet (default: m) 5. TANK LEVEL/TANK TEMP display: (default: TANK TEMP) 6. Alarm set:0:00 23:59 (default: 12:00, disabled) 10

7. Water level HI-alarm:0 15m(0 feet - 49.2 feet)(default: 10m, OFF) 8. Water level LO-alarm:0 15m(0 feet - 49.2 feet)(default: 2m, OFF) 6. SPECIFICATIONS Transmission distance: max.100 metres (in open space) Frequency: 433MHz Indoor temperature range: 0-50 C, Resolution: 1 C, Accurate:+/-1 C, Tank temp measure range:-40-60 C, Resolution: 1 C, Accurate:+/-1 Water level measure range:0-15m, Resolution: 0.01m, Accurate: +/-0.03m Alarm duration: 120 seconds Power consumption Indoor receiver: 2 x AA 1.5V batteries Life: Minimum 12 months Tank transmitter: 6 x AAA 1.5V batteries Life: Minimum 24 months Distributed by: Sontax Australia Phone: 1800 653 238 Email: sales@sontax.com.au Website: www.sontax.com.au Need assistance with set-up or operation? Before you return this product to the retailer, CALL US FIRST TOLL FREE: 1800 653 238 Monday Friday 7.30am 4.00pm (WST) EMAIL YOUR QUESTIONS TO: sales@sontax.com.au 11