Paper Chromatography: Separation and Identification of Five Metal Cations



Similar documents
Separation of Amino Acids by Paper Chromatography

Ink Analysis 2005, 2004, 2002, 1993 by David A. Katz. All rights reserved.

PAPER CHROMATOGRAPHY

RECITATION NOTES FOR EXPERIMENT # 5 A&B THIN LAYER CHROMATOGRAPHY

Separation of Dyes by Paper Chromatography

For Chromatography, you must remember Polar Dissolves More, not like dissolves like.

Fractional Distillation and Gas Chromatography

Physical and Chemical Properties and Changes

Organic Lab 1 Make-up Experiment. Extraction of Caffeine from Beverages. Introduction

Lab 6: Paper Chromatography. Pages Pre-lab page 151 No Post lab Chromatogram must be turned in attached to lab report

Thin Layer and Column Chromatography

Thin Layer Chromatography.

Hands-On Labs SM-1 Lab Manual

Experiment 5: Column Chromatography

PHYSICAL SEPARATION TECHNIQUES. Introduction

Experiment 12- Classification of Matter Experiment

EXPERIMENT 7 Electrochemical Cells: A Discovery Exercise 1. Introduction. Discussion

EXPERIMENT 7 Reaction Stoichiometry and Percent Yield

experiment5 Understanding and applying the concept of limiting reagents. Learning how to perform a vacuum filtration.

Recovery of Elemental Copper from Copper (II) Nitrate

In this experiment, we will use three properties to identify a liquid substance: solubility, density and boiling point..

8.9 - Flash Column Chromatography Guide

Prussian blue and cyanotype printing

GAS CHROMATOGRAPHY. DETERMINING THE PERCENT COMPOSITION OF A MIXTURE OF VOLATILE LIQUIDS USING A GAS CHROMATOGRAPH. (Revised: )

Mixtures and Pure Substances

Determination of a Chemical Formula

COMMON LABORATORY APPARATUS

Lab #13: Qualitative Analysis of Cations and Anions

SEPARATION OF A MIXTURE OF SUBSTANCES LAB

Determination of Melting Points

The Empirical Formula of a Compound

Experiment 8 - Double Displacement Reactions

THIN LAYER CHROMATOGRAPHY AND MELTING POINT DETERMINATION: DETECTION OF CAFFEINE IN VARIOUS SAMPLES

The Molar Mass of a Gas

Making Biodiesel from Virgin Vegetable Oil: Teacher Manual

Experiment 5. Chemical Reactions A + X AX AX A + X A + BX AX + B AZ + BX AX + BZ

Polarity and Properties Lab PURPOSE: To investigate polar and non-polar molecules and the affect of polarity on molecular properties.

EXPERIMENT 1 - Determination of the purity and identity of organic compounds by melting point and/or analytical thin layer chromatography

Properties of Acids and Bases

Chemistry 112 Laboratory Experiment 6: The Reaction of Aluminum and Zinc with Hydrochloric Acid

1. The Determination of Boiling Point

Extraction: Separation of Acidic Substances

Solubility Curve of Sugar in Water

Chemical Bonding: Polarity of Slime and Silly Putty

SYNTHESIS AND ANALYSIS OF A COORDINATION COMPOUND OF COPPER

1. Qualitative Analysis of Chromium, Iron, and Copper

Reaction of Magnesium with Hydrochloric Acid (Gas Laws) Chemicals Needed:

Food Dye Chromatography Student Laboratory Kit

General Chemistry I (FC, 09-10) Lab #3: The Empirical Formula of a Compound. Introduction

Building Electrochemical Cells

DYES AND DYEING 2003 by David A. Katz. All rights reserved. Permission for classroom use provided original copyright is included.

Partner: Jack 17 November Determination of the Molar Mass of Volatile Liquids

Santa Monica College Chemistry 11

Unit 1 - Pure Substances and Mixtures Chapter 2: Solutions

PREPARATION FOR CHEMISTRY LAB: COMBUSTION

IDENTIFICATION OF POLYMERS 1998 by David A. Katz. All rights reserved

CHEMICAL DETERMINATION OF EVERYDAY HOUSEHOLD CHEMICALS

Catalytic Activity of Enzymes

Lab: Properties of Polar and Nonpolar Substances

Physical Properties of a Pure Substance, Water

EXPERIMENT 12: Empirical Formula of a Compound

ISOLATION OF CAFFEINE FROM TEA

Chem 100 Lab Experiment #9 - ACID/BASE INDICATORS

Experiment 8 Synthesis of Aspirin

Separation by Solvent Extraction

Chapter 5, Lesson 3 Why Does Water Dissolve Salt?

SUCRALOSE. White to off-white, practically odourless crystalline powder

Amino Acids, Peptides, and Proteins

Experiment 7: Titration of an Antacid

Properties of Acids and Bases

105 Adopted:

Extraction of Caffeine from Energy Drinks

Electrochemical Half Cells and Reactions

Electrochemistry Revised 04/29/15

Austin Peay State University Department of Chemistry CHEM Empirical Formula of a Compound

Distillation Experiment

EXPERIMENT 8: Activity Series (Single Displacement Reactions)

Planar Chromatography

# 12 Condensation Polymerization: Preparation of Two Types of Polyesters

Shampoo Properties Evaluation General Science

Name. Lab 3: ENZYMES. In this lab, you ll investigate some of the properties of enzymes.

PREPARATION AND PROPERTIES OF A SOAP

Identification of Arson Accelerants by Gas Chromatography

SUPPLEMENTARY MATERIAL

Chemistry 321, Experiment 8: Quantitation of caffeine from a beverage using gas chromatography

Enzyme Activity Measuring the Effect of Enzyme Concentration

Fiber Analysis 2005, 2004, 2003, 2001, 1999 by David A. Katz. All rights reserved.

CHEMICAL REACTIONS OF COPPER AND PERCENT YIELD KEY

ANALYSIS OF PLANT PIGMENTS USING PAPER CHROMATOGRAPHY AND VISIBLE AND/OR UV SPECTROSCOPY ( )

Forensic detectives. magnifying glass Foot prints. brain training. Badge

Limiting Reagent (using an analogy and a learning cycle approach)

Titanium Dioxide Raspberry Solar Cell 2012, 2011, 2005 by David A Katz. All rights reserved

Experiment 9 Electrochemistry I Galvanic Cell

ACID-BASE TITRATIONS: DETERMINATION OF CARBONATE BY TITRATION WITH HYDROCHLORIC ACID BACKGROUND

Experiment 1: Colligative Properties

The Synthesis of trans-dichlorobis(ethylenediamine)cobalt(iii) Chloride

80. Testing salts for anions and cations

EXPERIMENT 3 (Organic Chemistry II) Nitration of Aromatic Compounds: Preparation of methyl-m-nitrobenzoate

CH204 Experiment 2. Experiment 1 Post-Game Show. Experiment 1 Post-Game Show continued... Dr. Brian Anderson Fall 2008

AN EXPERIMENT IN ALCHEMY: COPPER TO SILVER TO GOLD 2005, 2000, 1996 by David A. Katz. All rights reserved

Transcription:

Paper Chromatography: Separation and Identification of Five Metal Cations Objectives Known and unknown solutions of the metal ions Ag +, Fe 3+, Co 2+, Cu 2+ and Hg 2+ will be analyzed using paper chromatography. An unknown solution containing some of these cations will be identified by comparison to the R f values and colors of the stained spots of known solutions. Background Most chemists and many other scientists must routinely separate mixtures and identify their components. The ability to qualitatively identify the substances found in a sample can be critical. For example, an environmental chemist investigating samples of polluted ground water will want to know which toxic ions might be present in a sample. Chromatography is one of the first tools used in such situations. In this technique, many types of mixtures can be separated into the component pure substances; by comparison to a standard sample, each component substance can also be tentatively identified. Many varieties of chromatography exist, each one designed to separate specific types of mixtures. The common feature of each type of chromatography is that a mobile phase (a liquid or gas) is pushed through a stationary phase (a solid). Table 1 lists several varieties of chromatography and typical identities of the phases. Paper chromatography will be used in this experiment. TABLE 1 Type of Chromatography Mobile Phase Stationary Phase Gas (GC) Liquid (LC,HPLC, column) Paper Thin-Layer (TLC) inert gas (helium) waxy liquid or silicone inside narrow tubing solid packing (silica, alumina) paper silica/alumina coated glass, plastic or metal The example of column chromatography (Figure 1) demonstrates the typical features found in this analytical technique. The diagram shows an experiment where a two-component mixture is subjected to column chromatography. The column is packed with a solid material called the stationary phase. A liquid solvent or eluting solution is poured into the column and completely wets the solid packing material. Then the mixture is loaded onto the top of the wet column and more eluent is added. Gravity pulls the mobile phase down through the stationary phase and the components in the mixture start to move through the column at different rates. In the diagram, component A moves faster than component B; thus component B is retained on the column for a longer time than component A. Usually this is due to a difference in solubility of the two compounds in the solvent and/or to a difference in attraction to the solid packing material. As more eluent is added to the top of the column, the components will eventually exit the column separately. The time taken to exit the column, called retention time, will be reproducible for each component under the given set conditions mobile and stationary phase identities, temperature and column width. Once the components exit the column, the solvent can be removed by evaporation and the pure components can be further analyzed or identified. Paper Chromatography Page 1 of 5

Component B Component A Stationary Phase with Eluent Figure 1. A typical column chromatography experiment demonstrates the separation of a two-component mixture. Tentative identification of the components can be achieved by comparing the unknown mixture a carefully prepared known mixture: if a known component has the same retention time as an unknown component under the same conditions, it is probable but not conclusive that the two components are the same. Further analysis may be needed to confirm this hypothesis. If the known and the unknown have different retention times, then it is not likely that the two components are identical. Other variations of chromatography use capillary action the attraction of a liquid to a solid surface to pull a solvent through solid material. An informal version of paper chromatography can be observed when an ink-written page comes in contact with water or other liquids. The ink runs and several colors are separated in the ink streak. The diagram below (Figure 2) shows the result of a thin-layer chromatography experiment. Two black ink spots on the solid surface have had a solvent passed through them. The solvent is water or another liquid that is pulled through the stationary phase by capillary action. In this example, a piece of plastic coated with a powdered solid is used as the stationary phase. Alternatively a piece of filter paper can be used as the stationary phase. The experiment shows that the black ink is a mixture containing several different colored substances. Each component has a slightly different solubility in the mobile phase, so when the liquid is pulled through the stationary phase, each component moves at a different rate, separating the ink into spots of different colors. In this experiment, similar principles are used to separate several metal cations by a paper chromatography procedure. The metal ions Ag +, Fe 3+, Co 2+, Cu 2+, and Hg 2+ have differing solubility in the mobile phase aqueous HCl with ethyl and butyl alcohol and will move at different rates up the paper. The different metal-ion solubilities are probably due to the formation of various compounds with the chloride ion and their varying ability to dissolve in the organic solvent. A diagram showing how to prepare the paper is shown below. Standard solutions containing each of these ions will be spotted onto the paper using a capillary tube, along with a standard solution containing all five ions. An unknown will also be spotted onto the paper. Once the paper is prepared, it will be developed by placing the paper into the eluent. After 75-90 minutes, the paper is visualized by wetting it with an aqueous solution containing potassium iodide, KI, and potassium ferrocyanide, K 4 [Fe(CN) 6 ]. The unique color observed for each ion is produced by a chemical reaction with the visualization solution. This is one useful way to identify which ions are present in an unknown mixture. Figure 2: Thin-layer chromatography of black ink after development. This picture demonstrates a common problem where the spots widen as they move up the plate, eventually merging at the top of the plate. Paper Chromatography Page 2 of 5

20 cm Your Name(s) Tape 12 cm (5 single ions, 1X each) mixt. (3X) (2X and 4x, same unknown) 1.5 cm Known ions Unknown Mixture Figure 3: Diagram showing how to prepare the paper for the chromatography experiment The distance the ion moves up the paper can also be used to identify the ion. However, since students will develop their chromatography experiments for different amounts of time and under slightly different conditions, each student will have somewhat different measured distance for a given ion. The ratio of the distance moved by an ion (D) to the distance moved by the solvent (F, solvent front) is characteristic and should be nearly the same for all students. This ratio is called R f, or retention factor. R f = D F Procedure Safety Avoid contact with the metal ion solutions, the eluting solvent, and the visualizing solution. Wear disposable gloves to touch your chromatogram after the elution occurs and for the remainder of the experiment. Do not breathe the vapors of the eluting solvent or the visualizing solution. Place the wet chromatogram on a paper towel, not directly on the laboratory bench. Use the visualizing solution only in the space provided by your instructor. Dispose of the gloves and chromatogram in the specified waste container after the experiment is finished. Wash your hands thoroughly after contact with all solutions in this lab. Paper Chromatography Page 3 of 5

Materials and Equipment Chemicals: 0.1 M aqueous solutions of AgNO 3, Hg(NO 3 ) 2, Fe(NO 3 ) 3, Co(NO 3 ) 2, and Cu(NO 3 ) 2, each with dedicated capillary tubes; eluting solution (aqueous HCl with ethyl and butyl alcohol); visualizing solution (aqueous solution of KI and K 4 [Fe(CN) 6 ]). Equipment: Clean piece of chromatography paper; disposable Latex gloves (nitrile gloves are vailable in the stockroom for people with allergies to Latex); 600 ml beaker; plastic wrap; forceps or beaker tongs; ruler * *Items obtained from stockroom Preparation of the paper for chromatography 1. Each pair of students should obtain a piece of filter paper with the dimensions shown in Figure 3. Make sure the paper is clean and without tears or folds. Use a pencil not a pen and a ruler to draw a line across the paper one cm from the long edge of the paper. You will spot the metal ion solutions on this line. Write your name in pencil in the upper left-hand corner of the paper. 2. Practice spotting water and/or ion solutions onto a strip of filter paper so that you know how to create spots of the correct size. Use glass capillary tubes to spot the ions onto the paper. Solution is applied by lightly and quickly touching a capillary tube containing the solution to the line you drew on the paper. The spots should be between 5 8 mm in diameter. Spots larger than this will excessively spread out during the experiment and make analysis difficult. 3. Known 0.1 M aqueous solutions of AgNO 3, Hg(NO 3 ) 2, Fe(NO 3 ) 3, Co(NO 3 ) 2, and Cu(NO 3 ) 2 are provided in test tubes, each containing two or three capillary tubes. Starting on the left, mark the identity of the ion underneath each spot with a pencil; then spot each known ion carefully onto the line. Be careful to avoid contaminating the capillary tube with other ions and replace the capillary tubes back into the correct test tube. A test tube containing a known mixture of all five ions is also provided with a set of capillary tubes. Spot this mixture onto the line as well. Because this solution is more dilute than the single-ion known solutions, apply the known mixture three times, letting the spot dry between each application. A heat lamp will help to dry the spot more quickly. 4. Several unknowns are also provided in test tubes, along with capillary tubes. Your instructor will tell you which unknown should be used. The unknowns will contain between one and four cations, and are more dilute than the single-ion known solutions. The unknown will also need to be applied two and four times for the two trials, letting the spot dry between each application. In case of error, you should spot the unknown in two places along the line so that two trials are available for analysis. Developing the chromatography paper 1. Place a piece of tape along the upper right edge, as shown in Figure 3. Then form a cylinder by connecting the two short edges of the paper with the tape. Make sure the edges do not touch. The paper should look similar to Figure 4. 2. Obtain 15 ml of the eluting solution. Carefully pour some of this solvent into a 600 ml beaker and carefully swirl for a second or two. Caution: Do not breathe the vapors from this solution! Make sure that the level of the liquid will be below the spot line on the paper once the paper is placed in the developing chamber. Figure 4. Folded paper should look like this prior to developing the experiment. Paper Chromatography Page 4 of 5

3. Place the paper cylinder into the beaker with the marked edge down. The spots should be above the level of the solvent. The paper should not be touching the sides of the beaker. Carefully cover the beaker with plastic wrap and place it in the hood for 75-90 minutes. The solvent should start to move up the paper. Once the beaker is covered, make sure it is level and do not disturb it during the development period. Your instructor may have an assignment for you to work on while you wait. Visualization and analysis of the paper 1. Once the development period is over, wear disposable gloves and remove the paper from the beaker. Latex gloves are available in the lab and nitrile gloves are available in the stockroom for people with Latex allergies. Let any solvent drip back into the beaker, then remove the tape. Lay the chromatography paper on a paper towel and immediately mark the solvent front with a pencil. Pour the used eluting solvent into the waste container provided. Dry the paper under a heat lamp in the hood. Caution: Do not breathe the vapors! Be careful not to burn the paper under the lamp. 2. Once the paper is dry, bring it to the visualization station on the paper towel. Briefly dip the paper into the visualizing solution located in a shallow dish in the fume hood. Lift the paper out of the solution immediately and let any excess drip off at the station. Place the wet paper onto a dry paper towel and dry it under a heat lamp immediately, then carry it to your bench for analysis. 3. Find each known single-ion first and record the colors you observe. Some spots may fade over time, so record the colors while the paper is still wet. Measure the distance each spot moved, D, with a ruler. Measure to the center of each spot. Record your data in the data table. 4. Measure the distance to the solvent front, F. The value of F should be approximately the same across the entire paper. Use these values to calculate the R f for each ion. Make your measurements as shown in Figure 5. Each observed spot has its own R f value. Record your results in the data table. 5. In the lane containing the mixture, find each ion and record the distance moved by each ion. Calculate the R f for each ion in this lane. The values should closely Solvent Front match those observed in the single-ion knowns. F D Spotting Line Figure 5. Measurement of distances used in the calculation of Rf for a spot. 6. In the lane containing the unknowns, locate the center of each spot observed and record its distance and calculate the R f values. Use the lane that has the clearest spots. The color and R f values for the unknown spots should closely match some of the known ions. You should now be able to identify which ion or ions are found in your unknown. Record your data in the corresponding table. 7. Make a sketch of your chromatogram in the space provided on your lab report form, being sure to indicate the position and approximate size and shape of each spot on the paper. Dispose of the paper in the designated waste container. Cleanup Place the chromatography paper and the used gloves in the waste container provided. The used eluting solution should already have been placed into another waste container. Note that two different waste containers are provide for this experiment so be sure to read the labels so you will use the correct one! Be sure to wash your hands thoroughly before leaving the laboratory. Paper Chromatography Page 5 of 5