StarWind iscsi SAN & NAS: Multipathing October 2012



Similar documents
StarWind iscsi SAN & NAS: Configuring HA Storage for Hyper-V October 2012

StarWind iscsi SAN & NAS: Configuring HA File Server on Windows Server 2012 for SMB NAS January 2013

StarWind iscsi SAN & NAS: Configuring HA Shared Storage for Scale- Out File Servers in Windows Server 2012 January 2013

StarWind iscsi SAN: Configuring HA File Server for SMB NAS February 2012

StarWind iscsi SAN Software: Providing shared storage for Hyper-V's Live Migration feature on two physical servers

StarWind iscsi SAN Software: Using an existing SAN for configuring High Availability storage with Windows Server 2003 and 2008

StarWind iscsi SAN Software: Using StarWind with MS Cluster on Windows Server 2008

StarWind iscsi SAN Software: Installing StarWind on Windows Server 2008 R2 Server Core

StarWind iscsi SAN Configuring HA File Server for SMB NAS

StarWind SMI-S Agent: Storage Provider for SCVMM April 2012

StarWind iscsi SAN Software: Using with Citrix XenServer

StarWind iscsi SAN Software: Configuring High Availability Storage for VMware vsphere and ESX Server

StarWind iscsi SAN Software: Challenge-Handshake Authentication Protocol (CHAP) for Authentication of Users

StarWind iscsi SAN Software: Tape Drives Using StarWind and Symantec Backup Exec

StarWind Virtual SAN Installation and Configuration of Hyper-Converged 2 Nodes with Hyper-V Cluster

StarWind iscsi SAN Software: Using StarWind with VMware ESX Server

StarWind iscsi SAN: Configuring Global Deduplication May 2012

StarWind iscsi SAN Software: Using StarWind with MS Cluster on Windows Server 2003

StarWind iscsi SAN: Global Deduplication with Veeam Backup&Replication

StarWind RAM Disk: Using as RAM Disk Emulator

StarWind iscsi SAN Software: Implementation of Enhanced Data Protection Using StarWind Continuous Data Protection

StarPort iscsi and ATA-over-Ethernet Initiator: Using Mirror (RAID1) disk device

StarWind Virtual SAN Installing & Configuring a SQL Server 2012 Failover Cluster

VMware/Hyper-V Backup Plug-in User Guide

Installing and Configuring a SQL Server 2014 Multi-Subnet Cluster on Windows Server 2012 R2

StarWind Virtual SAN Hyper-Converged Platform Quick Start Guide

Using SMI-S for Management Automation of StarWind iscsi SAN V8 beta in System Center Virtual Machine Manager 2012 R2

StarWind Deduplication vs Nexenta Deduplication

istorage Server: High-Availability iscsi SAN for Windows Server 2008 & Hyper-V Clustering

istorage Server: High Availability iscsi SAN for Windows Server 2012 Cluster

Interact for Microsoft Office

Failover Manager for WhatsUp Gold v16.0 Quick Start Guide

ArCycle vmbackup. for VMware/Hyper-V. User Guide

Drobo How-To Guide. Topics. What You Will Need. Configure Windows iscsi Multipath I/O (MPIO) with Drobo iscsi SAN

STATISTICA VERSION 10 STATISTICA ENTERPRISE SERVER INSTALLATION INSTRUCTIONS

Smart Control Center. User Guide. 350 East Plumeria Drive San Jose, CA USA. November v1.0

Quick Start Guide For Ipswitch Failover v9.0

Using Device Discovery

WhatsUp Gold v16.2 Installation and Configuration Guide

Using Additional Pollers with WhatsUp Gold v16.0 Learn how to install, configure, and manage pollers for load balancing on your WhatsUp Gold system

Deploying the Workspace Application for Microsoft SharePoint Online

WhatsVirtual for WhatsUp Gold v16.0 User Guide

Secure Agent Quick Start for Windows

Drobo How-To Guide. Topics. What You Will Need. Prerequisites. Deploy Drobo B1200i with Microsoft Hyper-V Clustering

Symantec Enterprise Vault

PRODUCT WHITE PAPER LABEL ARCHIVE. Adding and Configuring Active Directory Users in LABEL ARCHIVE

Flow Publisher v1.0 Getting Started Guide. Get started with WhatsUp Flow Publisher.

Server Virtualization with QNAP Turbo NAS and Microsoft Hyper-V

Report Designer and Report Designer Add-In Installation Guide Version 1.0

#1 HyperConverged Appliance for SMB and ROBO. StarWind Virtual SAN Service Level Agreement

Sophos Anti-Virus for NetApp Storage Systems startup guide

Sage 200 Web Time & Expenses Guide

User Manual. Onsight Management Suite Version 5.1. Another Innovation by Librestream

Sage HRMS 2014 Sage Employee Self Service Tech Installation Guide for Windows 2003, 2008, and October 2013

QNAP in vsphere Environment

Sophos Endpoint Security and Control standalone startup guide

Using Symantec NetBackup with VSS Snapshot to Perform a Backup of SAN LUNs in the Oracle ZFS Storage Appliance

Internet Explorer 7. Getting Started The Internet Explorer Window. Tabs NEW! Working with the Tab Row. Microsoft QUICK Source

How to Configure a Secure Connection to Microsoft SQL Server

SOCET GXP V4.1 LICENSE MANAGER QUICK-START GUIDE

Creating IBM Cognos Controller Databases using Microsoft SQL Server

Dell One Identity Cloud Access Manager How to Configure for High Availability

Version 5.0. SurfControl Web Filter for Citrix Installation Guide for Service Pack 2

ECA IIS Instructions. January 2005

Integration Guide. Microsoft Active Directory Rights Management Services (AD RMS) Microsoft Windows Server 2008

PaperClip. em4 Cloud Client. Setup Guide

USB PORT NETWORK HUB. User Manual DA DA

Setting up VMware ESXi for 2X VirtualDesktopServer Manual

DESlock+ Basic Setup Guide ENTERPRISE SERVER ESSENTIAL/STANDARD/PRO

StreamServe Persuasion SP5 Control Center

Nexio Connectus Cluster Set Up with SQL Server Backend

Active Directory Provider User s Guide

Enterprise Manager. Version 6.2. Installation Guide

Drobo How-To Guide. What You Will Need. Configure Replication for DR Using Double-Take Availability and Drobo iscsi SAN

How to setup a VPN on Windows XP in Safari.

Dell Statistica Statistica Enterprise Installation Instructions

formerly Help Desk Authority Upgrade Guide

AvePoint CallAssist for Microsoft Dynamics CRM. Installation and Configuration Guide

LPR for Windows 95/98/Me/2000/XP TCP/IP Printing User s Guide. Rev. 03 (November, 2001)

genie app and genie mobile app

Installing Microsoft Exchange Integration for LifeSize Control

VRC 7900/8900 Avalanche Enabler User s Manual

Generating an Apple Enterprise MDM Certificate

Configuring Devices for Use with Cisco Configuration Professional (CCP) 2.5

Server Installation Guide ZENworks Patch Management 6.4 SP2

Sophos Mobile Control Installation guide. Product version: 3

Dell SupportAssist Version 2.0 for Dell OpenManage Essentials Quick Start Guide

Compellent Storage Center

Setting up Hyper-V for 2X VirtualDesktopServer Manual

Setting up Hyper-V for 2X VirtualDesktopServer Manual

WINDOWS 64-BIT INSTALLATION NOTES ORACLE VIRTUALBOX Micro Planner X-Pert V3.5.1 Digital Download Edition

Dell Recovery Manager for Active Directory 8.6. Quick Start Guide

File and Printer Sharing with Microsoft Windows

Installation & Activation Guide. Lepide Active Directory Self Service

Legal Notes. Regarding Trademarks KYOCERA Document Solutions Inc.

Live Maps. for System Center Operations Manager 2007 R2 v Installation Guide

Sophos UTM. Remote Access via PPTP Configuring Remote Client

SC-T35/SC-T45/SC-T46/SC-T47 ViewSonic Device Manager User Guide

Installing RMFT on an MS Cluster

Transcription:

StarWind iscsi SAN & NAS: Multipathing October 2012

TRADEMARKS StarWind, StarWind Software and the StarWind and the StarWind Software logos are trademarks of StarWind Software which may be registered in some jurisdictions. All other trademarks are owned by their respective owners. CHANGES The material in this document is for information only and is subject to change without notice. While reasonable efforts have been made in the preparation of this document to assure its accuracy, StarWind Software assumes no liability resulting from errors or omissions in this document, or from the use of the information contained herein. StarWind Software reserves the right to make changes in the product design without reservation and without notification to its users. TECHNICAL SUPPORT AND SERVICES If you have questions about installing or using this software, check this and other documents first - you will find answers to most of your questions on the Technical Papers webpage or in StarWind Forum. If you need further assistance, please contact us. Copyright 2009-2012 StarWind Software Inc. No part of this publication may be reproduced, stored in a retrieval system, or transmitted in any form or by any means, electronic, mechanical, photocopying, recording or otherwise, without the prior written consent of StarWind Software. Page 2

CONTENTS INTRODUCTION... 4 CONFIGURING STARWIND SERVER... 5 CONFIGURING ISCSI CLIENTS... 9 WINDOWS SERVER 2008... 9 WINDOWS SERVER 2012... 18 CONTACTS... 28 Page 3

INTRODUCTION The diagram below illustrates the network architecture used in this document. Page 4

CONFIGURING STARWIND SERVER 1. Open a StarWind configuration file. Note: The default path is C:\Program Files\StarWind Software\StarWind\StarWind.cfg 2. Find the string "<!--<iscsidiscoverylistinterfaces value="1"/>-->" and uncomment it (should look as follows: <iscsidiscoverylistinterfaces value="1"/>). 3. Restart StarWind Service. 4. Launch StarWind Management Console: Start -> All Programs -> StarWind Software -> StarWind. Note: The StarWind Console icon appears in the system tray when the Console is running. To open StarWind Management Console, double-click the icon or right-click it and then select Start Management Console from the shortcut menu. 5. Select the server you want to provide with the iscsi target device from the Console tree. Double-click the host to connect. Note: If you are prompted to enter login and password, specify root and starwind, relatively. These are the default login and password, but you can always change them later. 6. After connecting to StarWind Service, you can create devices and targets on the server. Open Add Device Wizard by one of the following ways: Select Add Device from the Target menu. Select Add Device from the Devices shortcut menu (right-click to open it). 7. Add Device Wizard appears. Please, follow the wizard's steps to complete creation of a new image file device. Page 5

8. Select Virtual Hard Disk -> Image File device. 9. Click Next to continue. 10. Select the Create new virtual disk option. 11. Click Next to continue. Page 6

12. Specify required virtual disk parameters. 13. Click Next to continue. 14. Select a virtual disk that will be made accessible via iscsi. 15. Click Next to continue. Page 7

16. Specify cache parameters of an image file device. 17. Click Next to continue. 18. Specify target parameters. Select Allow multiple concurrent iscsi connections (clustering) checkbox. 19. Click Next to continue. 20. Check whether device parameters are correct. Click Back to make any changes. Click Next to continue. 21. Click Finish to close the wizard. Page 8

CONFIGURING ISCSI CLIENTS Windows Server 2008 1. Launch Server Manager, select the Features item and click Add Features. Select Multipath I/O from the features list. Follow the wizard s instructions to install it. 2. Launch Microsoft iscsi Initiator: Start > Administrative Tools > iscsi Initiator. Navigate to the Discovery tab. 3. Click Discover Portal. In the Discover Target Portal dialog enter the first IP address of the StarWind Server. Click OK. Page 9

4. Click Discover Portal again. Enter the second IP address of the StarWind Server. Click OK. 5. Navigate to the Targets tab. The previously created target is listed in the Discovered Targets section. Note: If the created target is not listed, check the firewall settings on the StarWind Server as well as a list of networks served by the StarWind Server (go to StarWind Management Console -> Configuration - > Network). 6. Select the target and click Connect. Page 10

7. In the Connect to Target dialog select Add this connection to the list of Favorite Targets and Enable multi-path checkboxes. Click Advanced. 8. Select Microsoft iscsi Initiator in the Local adapter text field. In the Target portal IP select the first IP address of the StarWind Server. 9. Click OK. As you return to the previous dialog, click OK to go back to iscsi Initiator Properties. Page 11

10. Select the same target and again click Connect. 11. Perform the same actions as described above; this time specify another IP address as a target portal IP. Click OK. 12. Connect the second path of the target and close the MS Initiator. Page 12

13. Open the MPIO manager: Start -> Administrative Tools -> MPIO. 14. Go to the Discover Multi-Paths tab. Select the Add support for iscsi devices checkbox and click Add. 15. When prompted to restart the server, click Yes to proceed. Page 13

16. After the system reboot open the MPIO Manager again to ensure that the multipathed device has been recognized and added. A new device has to be displayed in the Devices list of the MPIO-ed Devices tab. Page 14

17. Open the iscsi Initiator and view the target properties. Select the target and click Properties. Page 15

18. The Sessions tab contains two sessions that represent both network paths that you have set. Page 16

19. Click Devices. This window displays general information about devices. 20. Click MPIO. Select a load balance policy of your connections. A brief description of the selected policy is provided beneath the Load balance policy box. Page 17

Windows Server 2012 1. Launch Server Manager, select the Manage item and click the Add Roles and Features option. Install the Multipath I/O feature by following the wizard s steps. 2. Click Next. Page 18

3. Select Role-based or feature-based installation as an installation type and click Next to continue. 4. Select the Select a server from the server poll option and select the appropriate server. Page 19

5. Click Next. 6. In the features list select Multipath I/O feature and install it. 7. Launch Microsoft iscsi Initiator: Start > Administrative Tools > iscsi Initiator. The iscsi Initiator Properties window appears. 8. Navigate to the Discovery tab. 9. Click Discover Portal. Enter the first IP address of the StarWind Server in the appropriate field of the Discover Target Portal dialog. Click OK. 10. Again click Discover Portal to add the second IP address of the StarWind Server. Page 20

11. Click the Targets tab. The previously created targets are listed in the Discovered Targets section. Note: If created targets are not listed, check the firewall settings of the StarWind Server as well as the list of networks served by the StarWind Server (go to StarWind Management Console -> Configuration - > Network). 12. Select the targets and click Connect to add it. 13. Select Add this connection to the list of Favorite Targets and Enable multi-path checkboxes in the Connect to Target dialog. Click Advanced. Page 21

14. Select Microsoft iscsi Initiator in the Local adapter text field. In the Target portal IP select the first IP address of the StarWind Server. Click OK. 15. Click OK to return to MS Initiator main window. Page 22

16. Select the same target and again click Connect. Perform the same actions as described above; this time specify another IP address as a target portal IP. Click OK. 17. Connect the second path of the target and close the MS Initiator. Page 23

18. Open the MPIO manager: Start -> Administrative Tools -> MPIO. 19. Go to the Discover Multi-Paths tab. Select the Add support for iscsi devices checkbox and click Add. 20. When prompted to restart the server, click Yes to proceed. Page 24

21. After the system reboot open the MPIO Manager once again to check whether the multipathed device has been recognized and added. A new device should be displayed in the Devices list of the MPIO-ed devices tab. 22. Open the iscsi Initiator to check the target properties. Select the target and click Properties. Page 25

23. The Sessions tab contains two sessions that represent both network paths that you have set. Page 26

24. Click Devices. This window displays general information about devices. 25. Click MPIO. Select a load balance policy of your connections. A brief description of the selected policy is provided beneath the Load balance policy box. Page 27

CONTACTS Customer Support Portal: Support Forum: Sales: Sales (Germany): General Information: http://www.starwindsoftware.com/support http://www.starwindsoftware.com/forums sales@starwindsoftware.com vschmidberger@starwindsoftware.com info@starwindsoftware.com US Headquarters Phone: 1-617-449-7717 Fax: 1-617-507-5845 EMEA and APAC Phone: +44-0-2071936727 +44-0-2071936350 +33-0-977197857 (French) Voice Mail: 1-866-790-2646 Germany Monikastr. 13 53757 Sankt Augustin Phone: +49-1715109103 StarWind Software Inc. 40 Mall Rd., Burlington, MA 01803, USA Page 28

www.starwindsoftware.com Page 29