Risk Analysis report (NS-EN ISO 14971)



Similar documents
RESTWELL RISE & RECLINE ARMCHAIRS BORG - OWNER S HANDBOOK PARTS DESCRIPTION

SERVICE MANUAL. Corpus 3G. Seat system for electric wheelchair

AUDIT. By Alegre Design.

Atigra T2 Seat System Notes for the Therapist

Basic price 2.250,- Excl. VAT

APP LOVE WORK DESIGNED WITH LONGEVITY AND DURABILITY IN MIND.

Section 14. Forklift Safety Contents 14.1 Operator Safety

Photo is courtesy of Enable-Me COMFORT SUPERIOR SEATING ACCESS ADJUSTABILITY. REHAB SHOWER COMMODE CHAIRS The Choice of Health Care Professionals

Uno 102. Product Description. Instruction Guide

Indications for a PMD as Reasonable and Necessary and Types of PMD Categories Available

Think of the environment before printing! Fax only contains page 1!

Reviews of the latest healthcare furniture HEALTHCARE FURNITURE REVIEW

KVT-729DVD INSTALLATION MANUAL

Autobody/Collision and Repair Technology/Technician CIP Task Grid

EZ-Steer Assisted Steering System

OWNER`S MANUAL. Permobil C300. Power Wheelchair

Massage, Heat & Air Systems

User Manual Swifty Rehabilitation Buggy. Thomashilfen. Kinder- Reha

Anatomy of a Manual Wheelchair

ZAPPY 3 OWNER S MANUAL. Read this manual completely before riding your Electric ZAPPY 3.

301.7D. Mini Hydraulic Excavator

MADE IN BRITAIN NHS & HEALTHCARE COLLECTION

GeekDesk Max Instructions for Assembly & Use

EXCAVATOR SAFETY TRAINING

Vascular Ultrasound Tables. and Accessories IODEX ISO 9001:2008 ISO 13485:2003 CERTIFIED. The Clinical Advantage

DLC:GH B6CJ6A HJEEA:B:CI

15GAL STEEL OIL DRAIN WITH 110V PUMP

User s Manual XXL Care Lift, Electrically Elevating Shower-, Commode- & Care Lift with Tilt-in-Space Seat Unit

BINGO Evolution. BINGO Evolution by HOGGI. BINGO was good - we just made it better. Made in Germany

Sport Ice Elektro 124

Benefits for Home Health Power Wheelchairs to Change

LIFTING EQUIPMENT. Pallet Trucks 36. Scissor Lifts 38. Electric Platforms 40. Lifters & Stackers 41. Spare Parts 46

S&W Race Cars and Components, Inc.

AND DESIGN FROM CONCEPT. Why did we develop Xenon? Experienced team. Christopher Schmidt

Patient Lifts SAFETY GUIDE

Crane control unit KST 3

EZ-Steer Assisted Steering System Installation Instructions Platform Kit P/N

OWNER S MANUAL. Permolock C3. Docking system for Power wheelchair in vehicle

MOVING YOU FURTHER HYUNDAI HEAVY INDUSTRIES

User Manual Viktoria/Viktor Power MPF

IMPORTANT INSTRUCTIONS & OPERATING MANUAL. Houston 50 Inch Electric Wall Mounted Fireplace Black / White

Folding Power Chair PHFW-1118 PHFW-1120 PHFW-1018 PHFW-1020

Model 1756 Test Lead Kit

This booklet was prepared by the Régie de l assurance maladie du Québec, in collaboration with the Association des établissements de réadaptation en

2014 FURNITURE. (844)

Designed for comfort and built to last.

Long-Life Hand Pallet Trucks and Hand Stackers

Toyota Hand Pallet Trucks

Owner s Manual Read and keep this manual. Patents World Wide

Luna/200. Luna/275. Ceiling hoist. User instruction. Important - warning. This manual must be read before the Luna is used

OWNER`S MANUAL. Street. Power Wheelchair

SLED-BASE ARM CHAIR 4-LEG ARMLESS CHAIR WITH STACKING DOLLY 4-LEG ARM CHAIR

Ahrend 750 The Smart Office. Ahrend 750 The Smart

Permobil M300 Corpus HD

OCE. A guide to using an electric wheelchair safely. Information for patients and their families. page 1

Product Presentation. March 2014 ww.solaxmobility.com 2014 Solax Mobility

INSTALLATION AND OPERATION MANUAL. Batteries for electric drive of bikes EVBAT48V9A-R EVBAT36V13A-R

Li Battery Pack & Charger Safety & Operating Instructions

Morgue refrigeration unit

FORTE REACH TRUCKS TERGO UNS/UHS

TCO Certified Edge Displays 1.2

Chairman Entra. Owner s manual

Now available with full IP65 rating: Protection from dust and water jets NEW: K470 Plus covered containers

TEMPO LOW-LEVEL ORDER PICKERS PPL/PPF/PPD/PPC FOR INTENSIVE ORDER-PICKING FROM GROUND LEVEL AND LEVEL 1

Best Practice Guide Vehicle Ergonomics Best Practice Guide

Waste Services Collection Service

Prime TC. Transport Chair. Patient Transport Redefined.

EZ-Steer Assisted Steering System

DIAMOND Retractable Rodding Robot Model SPRAYROD-R

804 Ti Stand. Manual EN

More Comfort. ICLS: Intuitive ControL Steering

Office of the Chief Procurement Officer Page 1 BID NUMBER RT

Excel G5 user manual ~ 1 ~

Base Cabinet with Self-storing Folding Doors and Floor

POP Pushchair. Instructions

4.3-inch Back-Up Camera

RISER & INCLUSION OF LIFESTYLE IMAGERY? + RISE & RECLINE IMAGERY

Available with and without arms, left or right hand tablet arms and with glides or casters.

CELO5. User & Installation Manual.

Chairman 2k/2s. Owner s manual

HUR Rehab Line H E A L T H & F I T N E S S E Q U I P M E N T

BUGGY SETUP GUIDE. Volume GOKARTSUSA GY6 150, CN250. Buggy Setup Guide

MONDOATHENS BASKETBALL SET (Reference PK110)

Nokia Bluetooth Headset BH-607. Issue 2. 1

Recommended Forklift Free System Features for Proper Safety and Ergonomic Operation

19" Data Racks. Adjustable feet To compensate for uneven floors and assure great stability all feet can be up to 20 mm adjusted.

ELECTRICAL PLUG TYPE CONNECTIONS

TCO Certified Edge Displays 2.0

Invacare REA Dahlia 45 Transit Dealer Max User Weight 135Kg (21 stone)

TOYOTA Tundra BACK-UP CAMERA SYSTEM Preparation

TIG INVERTER INSTRUCTION MANUAL

CAUTION RISK OF ELECTRIC SHOCK DO NOT OPEN

3.1.1 Full Type Tests & Routine Tests according to Clause 8 2 & Instructions For Installation, Operation & Maintenance

1. CONGRATULATIONS! You have bought a great new product from MAGICFX.

The Ideal Solution for Hospice Care

In today s fast moving world, there is a. low cost and on time, to satisfy the needs. Simple to Use, Easy to Maintain and

2016 Evolocity High Schools competition Technical regulations

ICS Will supersede EN 12184:1999. English version. Electrically powered wheelchairs, scooters and their chargers - Requirements and test methods

Toyota Powered Pallet Trucks

Foam Firmness Measurements IFD For Most Furniture And Bedding Applications

Transcription:

Analysis conclusion After finished analysis, HEPRO AS concludes the following for the analysed product: By use in accordance with the Users Instructions or by probable user wrong-doings, it is not defined to be of any danger for the user or the environment that demands further actions. Products included in the risk analysis Item number Model 15004 Moto 1. Risk analysis dimension The analysis process includes specific demands on the leadership and the participants in the project. Hepros quality system (QA) that is certified in accordance with NS-EN ISO 9001:2000, has the necessary routines for attention. 2. Terms and definitions The analysis uses the standards definitions as described in section 2.1 2.22. 3. General demands to direction of risk analysis 3.1 National or regional regulated demands Independent from national or regional demands, section 3.3 and 3.4 are in force. 3.2 Leadership defined process for risk analysis Responsibility is covered by the routines described in the QA-system. During the process the following areas are covered: Risk analysis Risk evaluation Risk control Post production information and experience 3.3 Leadership responsibility Policy for risk analysis and basic factors: The product shall satisfy the demands the international standards of requirements that Rikstrygdeverket demands for contract acceptance. Hepro ensures resources with necessary competence for carrying out the risk analysis. Hepro ensures correct competence during production of the product, in order to make sure that the product is presented with the characteristics that were basis for the risk analysis. Every change, large or small, shall be evaluated against the current risk analysis before the change is approved and executed. Special adaptation must be considered particularly against the risk analysis in order to ensure that a rebuilding does not lead to unintended risk for the user or the environments. Electrical powered wheelchairs Ed: 05 Date: 30.04.06 Page 1 of 6

3.4 Approval of personnel The QA systems demands on education and qualification of personnel covers this demand. 3.5 Plan for risk analysis A particular plan is not worked out but analysis is included into defined activities such as design, construction and production. The finished product shall be approved in accordance with relevant international standards before it is released to ordinary production and marked deliverance. 3.6 Documentation of risk analysis All risk analysis based upon NS-EN ISO 14971 are worked out based upon this documents template, and store on separate area on Hepros server. New evaluation of the existing risk analysis will be carried out by product changes or approval in accordance with new standards or customer defined demands. 4.0 Risk analysis 4.1 Basis for risk analysis Based upon the following the risk analysis is executed: a) Product description: Moto is built on a welded steel frame which has fixing point for wheels, motors, batteries, lifting unit and plastic covers. The lifting unit is cone shaped in the end where the seat unit is fixed. The seat unit consists of seat frame, seat cushion, backrest cushion and armrests. The controller unit is fixed to the right armrest. Controller fixation bracket for left side mounting is accessory. Controller VSI has all operations for driving and seat lifting regulation built-in. The controller is delivered pre-programmed. A particular programmer is needed for the programming. Change of the programming shall primarily be executed by the supplier (HEPRO AS). Changing of the programming executed by others must be approved by the supplier. Programming on special executed products is executed by the supplier upon delivery. MOTO HAS: Electrically adjustable seat height Angle adjustable seat Adjustable armrests height/width Height adjustable leg support with angle adjustable foot plate Height- and angle adjustable backrest Electrical motor drive and parking brake on rear wheels Joystick steering. The console can be height and length adjusted, and removed backwards. It is locked in user position with snaplock. Anti-puncture wheels b) Responsible for the analysis: Technical Manager, Einar Øines c) Execution date: 30.04.2006 Electrical powered wheelchairs Ed: 05 Date: 30.04.06 Page 2 of 6

4.2 Description of assumptions for use and identification of aspects related to security. Assumptions for use: This is described in User Instructions for the product, particularly under the sections for safety regulations and warning. Tests in accordance with the following standards are carried out and passed though accredited test laboratories. (Test reports or confirmations are enclosed to the RTV-tender). Standard Name NS-EN 12182 Technical aids for disabled persons - General requirements and test methods. NS-EN 12184 Electrically powered wheelchairs, scooters and their chargers Requirements and test methods. NS-EN 1021-1 Furniture Assessment of the ignitability of upholstered furniture part 1: Ignition source: smouldering cigarette. NS-EN 1021-2 Furniture Assessment of the ignitability of upholstered furniture part 1: Ignition source: match flame equivalent. 93/42/EØF Equipment class I marked Examination of Annex A (A2.1 A2.28) gives the following terms regarding security, and will be analysed further in this report. Terms for further analysis in section 4.3 and 4.4: A 2.1 Description of correct use appears in the Users Instructions. A 2.2 The products are for inn-door use and are in direct contact with the user during use. A 2.3 Seat- and backrest cushions are of polyurethane foam covered with 100% trevira upholstery. A 2.4 Not relevant. A 2.5 Not relevant. A 2.6 Not relevant. A 2.7 Not relevant. A 2.8 Cleaning executed by the user is described in the Users Instructions. A 2.9 Not relevant. A 2.10 Not relevant. A 2.11 Not relevant. A 2.12 Not relevant. A 2.13 The wheelchairs have 2x 12V batteries that give an effective voltage of 24V. The batteries are secured by a main fuse. The digital controller has built-in protective circuits and controls the effect from the motor and other functionalities. A 2.14 Electrical security. EMC and inflammability. A 2.15 Electrical security and EMC. A 2.16 Not relevant. A 2.17 Necessary maintenance is described in the User Instructions and Technical Documentation. A 2.18 Digital programmable controller. A 2.19 Not relevant. A 2.20 The seat unit is ergonomically shaped, and may loose its qualities after loge time of fuse or through wear and tear. A 2.21 User weight and use is stated in the Users Instructions. A 2.22 Lifetime depends on user weight and user environment/conditions. A 2.23 The product is constructed and approved for 1 person. A 2.24 Special waste by destruction is: Controller, cables and batteries. The remaining is metal, PUR-foam and plastic. A 2.25 Necessary training is taken care of in the Users Instructions. Electrical powered wheelchairs Ed: 05 Date: 30.04.06 Page 3 of 6

Terms for further analysis in section 4.3 and 4.4: A 2.26 The production processes are always evaluated against possible risk consequences before change or implementing of a process. A 2.27.1 The products have accessories with belonging mounting instructions. A 2.27.2 Described in Technical documentation. A 2.27.3 Display and warning lamps give necessary information, see Users Instructions. A 2.27.4 Not relevant. A 2.28 The product is described in section 4.1 a). 4.3-4.4 are combined and taken care of in the table below. A 2.1 A 2.2 A 2.3 A 2.8 4.3 Identification of known and predictable risk Use without training or not in accordance with the user manual. Skin contact with Trevira CS and rubber materials. The products are constructed by well known materials, components and upholsteries. Cleaning is regarded as necessary preventive maintenance to uphold functionality. 4.4 Evaluation of consequences Violation of critical safety regulations and warnings. Allergic reactions. Generally increasing allergic tendencies in the population may give reactions from materials that the user gets in touch with. By lack of cleaning, the product may work insufficient, and seat comfort and ergonomic characteristics may be reduced. A 2.13 Water spoil during cleaning may penetrate the controller if it has external damages. May short-circuit the electronic board and cause permanent damage on the electronics. A 2.14 May be affected by external electronics. The user lose the steering of the product. A 2.15 May affect other electronics within the environment. Operation of the product lead activation of other electronically devices. A 2.17 The products consist of many movable parts and presume maintenance as described in order to work properly. The complete product looses its functionality or operation possibility. A 2.18 Change of approved controller programming. The product does not satisfy the approved safety demands. A 2.20 Long time use may lead to cushions with reduced pressure distribution effect. Reduced pressure distribution may cause unnecessary strain to the body. A 2.21 Stability and security presume that the given user weight is not exceeded. The product is used in conflict with warning and safety information. Breakage may occur on the product. The wheelchair may tip over as a consequence of larger weight than approved. Over turn may cause user damages. A 2.22 The life-time assumes that the user weight is not exceeded and that the product is used under the circumstances that is described and tested. Abnormal mechanical wear and tear on movable parts is related to weigh. The environment the product is used in affects components and surface treatment. A 2.23 The product is constructed, produced and tested for on person. Increased wear and tear caused by excess weight. Tip over risk and risk of person damage caused reduced stability. A 2.24 No particular risk. Consequences are of environmental character and A 2.25 The product is delivered from the HMS without giving necessary training to the user. not a risk for the user or the product. Use in conflict with the user instructions is always connected with risk for the user, and especially regarding excess weight and stability. 4.3 Identification of known and predictable 4.4 Evaluation of consequences Electrical powered wheelchairs Ed: 05 Date: 30.04.06 Page 4 of 6

risk A 2.26 No particular. The QA-system takes care of this Taken care of by QA instructions. in accordance with the scale of the change. A 2.27.1 Risk is wrong mounting or mounted on Depend on the function of the accessory. product not supposed for. A 2.27.2 Changing of the programming on the digital controller. The product is not safe, and herby not in accordance with the approval. A 2.27.3 No particular risk. None. A 2.28 The following risks are regarded relevant related to the products use and operation: 1. Use outside of the use area. 2. Over tip danger if used in high speed and the seat unit in high position. 3. Backward tip danger. 4. Fire damages. 1. Wrong use may cause damages on user or the product. 2. The speed must be adapted to the driving. 3. Carelessness by obstacle force. The product is secured by anti-tip wheels. 4. Cigarette or cigar smoking. 5 Risk evaluation Based upon the table above (4.3 and 4.4) the following evaluation is done: A 2.1 A 2.2 A 2.3 A 2.8 A 2.13 A 2.14 A 2.15 A 2.17 A 2.18 A 2.20 A 2.21 A 2.22 A 2.23 A 2.24 A 2.25 A 2.26 A 2.27.1 Evaluation Risk regarded not relevant, necessary information and guidance are included in the delivery responsibility. Risk regarded relevant. Skilled personnel must take care of this together with the user if the user has allergic problems. Risk regarded relevant. Skilled personnel must take care of this together with the user if the user has allergic problems. Risk regarded not relevant since the cleaning information are included in the delivery responsibility. Risk regarded not relevant. Shall be taken care of by the user report responsibility by damage or by suspicion. Risk regarded not relevant. The products are tested for EMC. Risk regarded Not relevant. The products are tested for EMR. Risk regarded relevant. The user s maintenance responsibility is taken care of by through the official skilled persons training responsibility and is described in the users instructions. Risk regarded as minimal. Necessary programming equipment is available only for qualified personnel and external service representatives. Risk regarded relevant for users who stays in the chair for long periods. Skilled personnel must take care of this aspect if the user is disposed for problems. Risk regarded relevant. Skilled personnel and HMS must ensure that there is conformity between the products performances, limitations and the users needs. This is particularly regarding weight limitations and areas of use. The supplier (HEPRO AS) has few possibilities to influence wrong use of the products. Risk regarded relevant. Skilled personnel and HMS must ensure that there is conformity between the products performances, limitations and the users needs. This is particularly regarding weight limitations and areas of use. The supplier (HEPRO AS) has few possibilities to influence wrong use of the products. The risk is regarded as minimal since the seat unit is designed for 1 person. Risk regarded not relevant. Risk regarded relevant. All products demand training and imparted knowledge about where to find information about critical product use. Evaluation Risk regarded not relevant. Risk regarded minimal. HMS that owns the product is always the one that order accessories. HMS has in their control that qualified personnel perform the mounting of the accessories. Electrical powered wheelchairs Ed: 05 Date: 30.04.06 Page 5 of 6

A 2.27.2 A 2.27.3 A 2.28 Risk regarded minimal. Technical papers, information and training take care of this. Risk is minimal. This is an essential element in the training that is HMS responsibility. As supplier we regard the risk as properly taken care of through development and product testing, combined with the specifications in the users instructions. 6. Need for repeated risk evaluation We hereby conclude that section 5 Risk evaluation does not need repeated risk evaluation and the analysis is ended and fulfilled. (Improvement process and repeated evaluation are carried through by following the standards section 6.1 6.7.) 7. Total remaining risk evaluation No known circumstances require new risk analysis process. 8. Risk analysis report The risk analysis documentation is covered with this report. 9. Re-examination and follow-up of the risk analysis report The risk analysis will be re-examined by every production change, change of use conditions and work processes where it s demanded or regarded as necessary. Report preparation and approval This report is worked out in accordance with the demands in the standard and the intention to take care of the safety for the user and its environment. Rognan 30.04.2006 ----------------------------------------- Einar Øines Technical Manager Electrical powered wheelchairs Ed: 05 Date: 30.04.06 Page 6 of 6