Control Panels. Single-phase electric panels for submersible pumps QSM - QPC - QPCS - QSC - QSCS



Similar documents
LC/LCD ranges level controllers

Quick Connect. quick - simple - efficient.

PSR The compact range Description

Thyristor-controlled power supplies and battery chargers

Series description: Wilo-Drain TC 40

Products and solutions for lifting systems

HERZ-Thermal Actuators

VLT Series 3500 Adjustable Frequency Drive Instruction Manual

2CP. Twin-impeller pumps PERFORMANCE RANGE INSTALLATION AND USE APPLICATION LIMITS OPTIONALS AVAILABLE ON REQUEST CONSTRUCTION AND SAFETY STANDARDS

Bulletin 150 Smart Motor Controllers SMC-3 Smart Motor Controller

Type: DILM115(RAC240) Article No.: Sales text Contactor,55kW/400V,AC operated. Ordering information

Technical catalogue. Modular DIN rail components Installation contactors

Positive-guided relay outputs: 3 safety contacts (N/O), instantaneous. 1 auxiliary contact (N/C), instantaneous

BETA Switching. Switching Devices. 5TT5 8 Insta contactors, AC technology. Overview

Technical data UNIBLOCK UBSF

ABB i-bus KNX Fan Coil Actuator, MDRC FCA/S 1.1M, 2CDG R0011

Phone: Fax: Web: info@clrwtr.com

Electronic overload relay EF19 and EF45

Mini Motor Contactor J7KNA Main contactor Accessories Approved Standards Standard Guide No (US,C) Ordering Information tage Model Number Legend gear

Conlift1, Conlift2, Conlift2 ph+

Installation Contactors. Technical Catalogue. Type ESB. abb. ABB STOTZ-KONTAKT GmbH 1 2CDC C0201

AuCom s IMS2 soft starters are a total motor starting solution, combining highlevel functionality with ease of use:

SURGE PROTECTIVE DEVICES

Single-phase ( V) voltage monitoring: Undervoltage Overvoltage Window mode (overvoltage + undervoltage) Voltage fault memory selectable

Current valve. for AC 24 V pulse/pause control of electrical loads up to 30 kw

33.6W Power over Ethernet Waterproof Adapter PoE Plus Single Port Injector for Outdoor Application

Products and solutions for machine builders (OEM) 100% electricity

..OR How To Protect your 3-Phase Equipment Investment with 3-Phase Monitors from Time Mark...

ADS8 IP54 Direct-On-Line Starter Technical Focus. Replaces ADS7 Rated up to 9kW

Number 1 in efficiency

Electronic overload relay EF65, EF96 and EF146

REVIEWED BY CAPITAL PROJECTS MANAGER (DAN REDDY) GENERAL MANAGER EQUIPMENT ENGINEERING & ASSET MANAGEMENT (HAMILTON NXUMALO)

JNIOR. Overview. Get Connected. Get Results. JNIOR Model 310. JNIOR Model 312. JNIOR Model 314. JNIOR Model 410

Power Supply Unit, Primary Switched, Narrow Design MINI-PS-12-24DC/24DC/1

PS1800 Centrifugal Pumping Systems

Electric Rotary Actuator - On/Off or programmable control actuator

Example of use: Fuse for a solenoid valve. If the fuse is defective, no information is sent to the electronic component.

Heating, air-conditioning, cooling

Fluid Level Gauge Fluid Level Sensor Temperature Switch FSA / FSK / TS

IDEAL INDUSTRIES, INC. TECHNICAL MANUAL MODELS:

Series description: Wilo-Star-Z

Vario-Series Accessories

Centro-Matic Automatic Lubrication Systems System Controls

Frequency Converter Fv

Technical Data. back-up time in minutes 100% load % load

XFE. The cost effective starter for all AC induction motors from 4A 2800A The choice for small to medium industrial applications

IntesisBox KNX LG Air Conditioning

3-phase, bidirectional energy meter

Products and solutions for pumping, irrigation and piping

Control Devices Catalogue. Control Devices. Preferred and Standard Products

Power Thyristor TS3 (SP) 3ph. Installation Guide

Electronic, Digital and Mechanical Vibration Switches

Model: DC-A2IO Advanced HVAC Controller

Power Supplies 3. SDN-P DIN Rail Series

NIVOCONT CONDUCTIVE LEVEL SWITCHES LEVEL SWITCHES

APPENDIX A PIN-OUT OF RJ12 / RJ45 CONNECTORS. RJ12 connectors

VIBRATION MONITORING OF FANS INSTALLED IN ROAD TUNNELS

How To Drive A Compact Serie 1

LTR Series Uninterruptible Power Systems 700 VA KVA. General Specification

MICROSENS. Central 48 V DC Power Supplies for PoE-Components. Description. Features

Manual motor starter MS116

HEAT MONITORING AND CONTROL INSTRUMENTS FOR TRANSFORMERS MB 103 TEMPERATURE CONTROL UNIT PT 100 TEMPERATURE SENSOR

DLW 8. POWER RATING 1500 rpm/50 Hz 1800 rpm/60 Hz Prime 7.5 kva, 6 kw 9.1 kva, 7.3 kw Standby 8.5 kva, 6.8 kw 10.1 kva, 8.1 kw

How To Control A Power Supply With A Mini Transmitter And Switch (Power Supply)

40.3. Control Relays and Timers

SMS 4 / SMS 5 safety mat Product information

32:(5#5$7,1* 4833#USP283#+] 4;33#USP293#+] 3ULPH 10.4 kva, 8.3 kw 12.9 kva, 10.3 kw 6WDQGE\ 11.3 kva, 9 kw 14.4 kva, 11.5 kw

Operating Manual for the Electronic Built-in Interval Timer. Micro II (Countdown Timer)

PPS-PPQ-BT-PIAS RESIN INSULATORS FOR OIL INSULATED ELECTRICAL MACHINES

E-STOP relays, safety gate monitors

APC. DIN Rail Control Panel Mounting Uninterruptible Power Supply. Catalog

Actuator-Sensor-Interface

Digital inductive conductivity transmitter

R4D0-FB-IA* FieldBarrier. Features. Assembly. Function. Connection IN + - S OUT Spur 2. Spur 1. Zone 1. Zone 0

Electronic Control Devices The European Product Catalogue 2007

Max primary circuit temperature 90ºC Max primary circuit temp. 90ºC Max secondary circuit temperature 45ºC Max secondary circuit temp.

Maximum Demand Control

3753 en /b VE/B - VE/RG Va V riable speed drives

Analogue Input, 4-fold, MDRC AE/S 4.1, GH Q R0001

E-STOP relays, safety gate monitors

Bulletin 150 SMC Flex Smart Motor Controller Specifications

Outdoor 33.6W Dual Port Passive Power-over-Ethernet Midspan For External Security Cameras and Wireless Access Points

SPEED CONTROL SYSTEM

TECHNICAL SPECIFICATION FOR PROJECTION WELDING MACHINE (Qty. 2 Nos.)

Thermistor motor protection

Power factor correction and harmonic filtering. Rectimat 2 Automatic capacitor banks. Catalogue. Building a New Electric World

A project to optimise quality and energy efficiency must include metering

Stroom voor elke toepassing

Défumair XR. ventilation and cmv. fire grade - label CE. smoke-extraction fan extraction casing for kitchen at F advantages.

I STAR COMPUTER CO., LTD

Series 8146/5-V37 and Series 8150/5-V37

UPS UNINTERRUPTIBLE POWER SUPPLY GLOBAL SPECIALIST IN ELECTRICAL AND DIGITAL BUILDING INFRASTRUCTURES

SICONT Limit Switches Type 3SE3 upto 500 VAC, 600 VDC, 10A

Product and Applications Description. Application Programs. Example of Operation. GAMMA instabus Technical Product-Information.

Your Advantages For safety application up to PL e / Cat. 4 e.g. SIL 3 Manual or automatic start * see variants. Applications.

Art.S001-S002 SOLAR MODULE WITH DELIVERY AND RETURN CONNECTIONS

Digital Pressure Measuring Instrument MDR480

AUTOMATIC TRANSFER SWITCH. Changeover Type from 250A to 2500A

RM17TE V AC. Main. Product or component type. Product specific application. Relay monitored parameters 250 V DC 5 A DC

ETZGAR CONVEYOR COMPANY Controls Section v12.05

Transcription:

Control Panels Single-phase electric panels for submersible pumps QSM - QPC - QPCS - QSC - QSCS Electric panels for surface or submergible pumps QM - QTD - Q3A - Q3D - Q3Y - Q3I - Q3SF Electric panels for drainage pumps QDR - QDR2 - QDRM - QDRMC - QDRM2 - QDRMC2 - QGMC - QYR - QYR2 - QXR20 Auxiliary electric panels and accessories QCL5 - QCL10 - QCLP10 - KSL - DPF - VR - SCA3 518 528 542 562 51

QSM Series Single-phase electric panels for the protection and control of a 4 single-phase borehole pump. Main switch for manual control Supply voltage: 1 x 220-240 V ±5% Frequency: 50 Hz Power: 0.25 to 1.1 kw Direct motor starting Protection: IP43 Ambient temperature: -5 to +40 C (limit specified by EN standard 60439-1) Maximum relative humidity: 50% at +40 C provided that no condensation occurs (limit specified by EN standard 60439-1) Wall mounted Plastic enclosure Built-in capacitor Thermal protection inside panel Special versions available on request QSM PF version with overvoltage protection (lightning protector) For proper electric panel-electric pump selection, make sure that the Ampere input of the motor falls within the rated current range shown in the table. 518

QSM SERIES MODEL RATED RATED RATED CAPACITOR DIMENSIONS WEIGHT VOLTAGE POWER CURRENT 450V A B C V kw HP A uf mm mm mm Kg QSM 02 220-240 0,25 0,33 2,6 12,5 80 210 65 0,45 QSM 03 220-240 0,3 0,5 3,4 16 80 210 65 0,45 QSM 05 220-240 0,55 0,5 4,8 20 80 210 65 0,45 QSM 0 220-240 0,5 1 6,5 30 80 210 65 0,45 QSM 11 220-240 1,1 1,5 8,3 40 80 210 65 0,45 CB-QSM-en_c_te 519

QPC Series Single-phase electric panels for the protection and control of a 4 single-phase borehole pump. Main switch for manual control Supply voltage: 1 x 230 V ±10% Frequency: 50 Hz Power: 0.25 to 2.2 kw Direct motor starting Protection: IP54 Ambient temperature: -5 to +40 C (limit specified by EN standard 60439-1) Maximum relative humidity: 50% at +40 C provided that no condensation occurs (limit specified by EN standard 60439-1) Wall-mounted using supplied brackets Plastic enclosure Built-in capacitor Main switch with thermal protector (manual reset) and power ON indicator light Optional accessories DPF single-phase module for overvoltage protection (lightning protector) For proper electric panel-electric pump selection, make sure that the Ampere input of the motor falls within the rated current range shown in the table. 520

QPC SERIES PANEL TYPE RATED RATED RATED DIMENSIONS WEIGHT VOLTAGE POWER CURRENT A B C V kw HP A mm mm mm Kg QPC/02 1 x 230 V ± 10 % 0,25 0,33 3 10 10 5 1,1 QPC/03 1 x 230 V ± 10 % 0,3 0,5 4 10 10 5 1,1 QPC/05 1 x 230 V ± 10 % 0,55 0,5 5 10 10 5 1,1 QPC/0 1 x 230 V ± 10 % 0,5 1 6 10 10 5 1,1 QPC/11 1 x 230 V ± 10 % 1,1 1,5 9 10 10 5 1,1 QPC/15 1 x 230 V ± 10 % 1,5 2 11 10 10 5 1,1 QPC/22 1 x 230 V ± 10 % 2,2 3 16 10 10 12 1,2 CAPACITOR F/450V 12,5 16 20 30 40 50 0 CB-QPC_a_te 521

QPCS Series Single-phase electric panels for the protection and control of a 4 single-phase borehole pump. Automatic control through an external contactor Supply voltage: 1 x 230 V ±10% Frequency: 50 Hz Power: 0.25 to 2.2 kw Low voltage auxiliary circuit 12 Vac Direct motor starting Protection: IP54 Ambient temperature: -5 to +40 C (limit specified by EN standard 60439-1) Maximum relative humidity: 50% at +40 C provided that no condensation occurs (limit specified by EN standard 60439-1) Wall-mounted using supplied brackets Plastic enclosure with see-through cover Built-in capacitor Main switch with thermal protector (manual reset) and power ON indicator light Power, pump running and dry running level indicator lights Overvoltage protection Dry running control through probes, float switch or minimum pressure switch Optional accessories Kit n 3 electrodes (probes) without cable Float switch Pressure switch For proper electric panel-electric pump selection, make sure that the Ampere input of the motor falls within the rated current range shown in the table. 522

QPCS SERIES PANEL TYPE RATED RATED RATED DIMENSIONS WEIGHT VOLTAGE POWER CURRENT A B C V kw HP A mm mm mm Kg QPCS/02 1 x 230 V ± 10 % 0,25 0,33 3 200 150 80 1,3 QPCS/03 1 x 230 V ± 10 % 0,3 0,5 4 200 150 80 1,3 QPCS/05 1 x 230 V ± 10 % 0,55 0,5 5 200 150 80 1,3 QPCS/0 1 x 230 V ± 10 % 0,5 1 6 200 150 80 1,3 QPCS/11 1 x 230 V ± 10 % 1,1 1,5 9 200 150 80 1,3 QPCS/15 1 x 230 V ± 10 % 1,5 2 11 200 150 80 1,3 QPCS/22 1 x 230 V ± 10 % 2,2 3 16 200 150 80 1,3 CAPACITOR F/450V 12,5 16 20 30 40 50 0 CB-QPCS_a_te 523

QSC Series Protection and control of a single-phase submersible electric pump for 4 wells. Main switch for manual control. Supply voltage: 1 x 230 V ±10%. Frequency: 50 Hz. Power: 0,25 to 4 kw. Direct motor start. Protection class: IP55. Ambient temperature: -5 to +40 C (according to EN 60439-1). Maximum relative humidity: 50% at +40 C, provided that no condensation occurs (according to EN 60439-1). Wall mounted. Plastic enclosure. Incorporated capacitor. Main switch with manual-reset thermal protection. Optional accessories DPF single-phase module for overvoltage protection (lightning protector). For proper electric panel-electric pump selection, make sure that the Ampere input of the motor falls within the rated current range shown in the table. 524

QSC SERIES MODEL RATED RATED RATED DIMENSIONS WEIGHT VOLTAGE POWER CURRENT A B C V kw HP A mm mm mm Kg QSC/02 1 x 230 V ± 10 % 0,25 0,33 2,5 4 205 220 160 1, QSC/03 1 x 230 V ± 10 % 0,3 0,5 4 6,3 205 220 160 1, QSC/05 1 x 230 V ± 10 % 0,55 0,5 4 6,3 205 220 160 1, QSC/0 1 x 230 V ± 10 % 0,5 1 4 6,3 205 220 160 1, QSC/11 1 x 230 V ± 10 % 1,1 1,5 6,3 10 205 220 160 1, QSC/15 1 x 230 V ± 10 % 1,5 2 10 16 205 220 160 1, QSC/22 1 x 230 V ± 10 % 2,2 3 16 20 205 220 160 2, QSC/40 1 x 230 V ± 10 % 4 5,5 25 32 280 220 160 3 CAPACITOR μf/450v 12,5 16 20 30 40 50 0 90 CB-QSC-en_d_te 525

QSCS Series Protection and control of a single-phase submersible electric pump for 4 wells. Automatic control through an external enable contact Supply voltage: 1 x 230 V ±10% Frequency: 50 Hz Power: 0,25 to 2,2 kw Direct motor start Protection class: IP55 Ambient temperature: -5 to +40 C (according to EN 60439-1) Maximum relative humidity: 50% at +40 C, provided that no condensation occurs (according to EN 60439-1) Wall mounted Plastic enclosure Incorporated capacitor Main switch with manual-reset thermal protection Dry running control with float or minimum pressure switch (available separately) Optional accessories DPF single-phase module for overvoltage protection (lightning protector) KSL series 24 V level kit Probe module for protection against dry running (set of three electrodes included in the supply) For proper electric panel-electric pump selection, make sure that the Ampere input of the motor falls within the rated current range shown in the table. 526

QSCS SERIES MODEL RATED RATED RATED DIMENSIONS WEIGHT VOLTAGE POWER CURRENT A B C V kw HP A mm mm mm Kg QSCS/02 1 x 230 V ± 10 % 0,25 0,33 2,5 4 280 30 160 3, QSCS/03 1 x 230 V ± 10 % 0,3 0,5 4 6,3 280 30 160 3, QSCS/05 1 x 230 V ± 10 % 0,55 0,5 4 6,3 280 30 160 3, QSCS/0 1 x 230 V ± 10 % 0,5 1 4 6,3 280 30 160 3, QSCS/11 1 x 230 V ± 10 % 1,1 1,5 6,3 10 280 30 160 3, QSCS/15 1 x 230 V ± 10 % 1,5 2 10 16 280 30 160 3, QSCS/22 1 x 230 V ± 10 % 2,2 3 16 20 280 30 160 3, CAPACITOR μf/450v 12,5 16 20 30 40 50 0 CB-QSCS-en_b_te 52

QM Series Single-phase electric panels for the protection and control of a 4 single-phase surface pump. Control through an external contactor Supply voltage: 1 x 230 V ±10% Frequency: 50/60 Hz Power: 0.25 to 2.2 kw Direct motor starting Protection: IP54 Ambient temperature: -5 to +40 C (limit specified by EN standard 60439-1) Maximum relative humidity: 50% at +40 C provided that no condensation occurs (limit specified by EN standard 60439-1) Wall mounted Metal enclosure Ready for installation of dry-running control with float or pressure switch (available separately) Power and thermal overload indicator lights Optional accessories VR1 single-phase varistor module for overvoltage protection (lightning protector) SLD series 24V level kit. Probe module for protection against dry running (set of three electrodes included in the supply) For proper electric panel-electric pump selection, make sure that the Ampere input of the motor falls within the rated current range shown in the table. 528

QM SERIES PANEL TYPE RATED RATED RATED DIMENSIONS WEIGHT VOLTAGE POWER CURRENT A B C V kw HP A mm mm mm Kg QM/02 1 x 230 V ± 10 % 0,25 0,33 1 1,6 235 265 150 5,8 QM/03 1 x 230 V ± 10 % 0,3 0,5 1,6 2,5 235 265 150 5,8 QM/05 1 x 230 V ± 10 % 0,55 0,5 2,5 4 235 265 150 5,8 QM/0 1 x 230 V ± 10 % 0,5 1 4 6,3 235 265 150 5,8 QM/15 1 x 230 V ± 10 % 1,5 2 6,3 10 235 265 150 5,8 QM/22 1 x 230 V ± 10 % 2,2 3 10 16 235 265 150 5,8 CB-QM_b_te 529

QTD Series Three-phase electric panels for the protection and control of a 4 three-phase surface or submersible pump. Control through an external contactor Supply voltage: 3 x 400 V ±10% Frequency: 50/60 Hz Power: 0.25 to 9.2 kw Direct motor starting Overload protection Protection: IP54 Ambient temperature: -5 to +40 C (limit specified by EN standard 60439-1) Maximum relative humidity: 50% at +40 C provided that no condensation occurs (limit specified by EN standard 60439-1) Wall mounted Metal enclosure Ready for installation of dry-running control with float or pressure switch (available separately) Power and thermal overload indicator lights Optional accessories VR3 three-phase module for overvoltage protection (lightning protector) Selection For proper electric panel-electric pump selection, make sure that the Ampere input of the motor falls within the rated current range shown in the table SLD series 24V level kit. Probe module for protection against dry running (set of three electrodes included in the supply) For proper electric panel-electric pump selection, make sure that the Ampere input of the motor falls within the rated current range shown in the table. 530

QTD SERIES PANEL TYPE RATED RATED RATED DIMENSIONS WEIGHT VOLTAGE POWER CURRENT A B C V kw HP A mm mm mm Kg QTD/02-03 3 x 400 V ± 10 % 0,25-0,3 0,33-0,50 0,63 1 235 265 150 5,8 QTD/03-05 3 x 400 V ± 10 % 0,3-0,55 0,55-0,5 1 1,6 235 265 150 5,8 QTD/05-0 3 x 400 V ± 10 % 0,55-0,5 0,5-1 1,6 2,5 235 265 150 5,8 QTD/0-15 3 x 400 V ± 10 % 0,5-1,5 1-2 2,5 4 235 265 150 5,8 QTD/15-22 3 x 400 V ±10 % 1,5-2,2 2-3 4 6,3 235 265 150 5,8 QTD/22-40 3 x 400 V ± 10 % 2,2-4 3-5,5 6,3 10 235 265 150 5,8 QTD/40-5 3 x 400 V ± 10 % 4-,5 5,5-10 10 16 235 265 150 5,8 QTD/5-92 3 x 400 V ± 10 %,5-9,2 10-12,5 16 20 235 265 150 5,8 CB-QTD_c_te 531

Q3A Series Three-phase electric panels for the protection and control of a 4 three-phase surface or submersible pump. Manual control through A-0-M switch Automatic control through an external contactor Supply voltage: 3 x 400 V ±10% Frequency: 50/60 Hz Low voltage auxiliary circuit 24 Vac Power: 4 to 315 kw Autotransformer starting Overload protection Protection: IP54 Ambient temperature: -5 to +40 C (limit specified by EN standard 60439-1) Maximum relative humidity: 50% at +40 C provided that no condensation occurs (limit specified by EN standard 60439-1) Wall mounted Metal enclosure Power - pump running - thermal overload - dry running indicator lights Ready for installation of dry-running control with float or pressure switch (available separately) Electronic protection module with electrodes can be fitted Optional accessories SLD series 24V level kit: Probe module for protection against dry running (set of three electrodes included in the supply) Float switch Pressure switch VR3/SCA3 three-phase module for overvoltage protection (lightning protector) For proper electric panel-electric pump selection, make sure that the Ampere input of the motor falls within the rated current range shown in the table. 532

0 25 0 150 200 Q3A SERIES A C 500 V 300 A L1-L2 L2-L3 L3-L1 50 0 B M 0 A MODEL RATED RATED RATED DIMENSIONS WEIGHT VOLTAGE POWER CURRENT A B C V kw HP A mm mm mm Kg Q3A/40-5 3 x 400 V ± 10 % 4-,5 5,5-10 10 16 500 00 250 50 Q3A/5-92 3 x 400 V ± 10 %,5-9,2 10-12,5 16 20 500 00 250 50 Q3A/92-110 3 x 400 V ± 10 % 9,2-11 12,5-15 20 25 500 00 250 50 Q3A/110-150 3 x 400 V ± 10 % 11-15 15-20 22 32 500 00 250 50 Q3A/150-185 3 x 400 V ± 10 % 15-18,5 20-25 28 40 500 00 250 50 Q3A/185-220 3 x 400 V ± 10 % 18,5-22 25-30 36 50 500 00 250 50 Q3A/220-300 3 x 400 V ± 10 % 22-30 30-40 45 63 600 900 300 80 Q3A/300-30 3 x 400 V ± 10 % 30-3 40-50 5 5 600 900 300 80 Q3A/30-450 3 x 400 V ± 10 % 3-45 50-60 0 90 600p 1300p 300p 90 Q3A/450-550 3 x 400 V ± 10 % 45-55 60-5 80 108 600p 1500p 300p 120 Q3A/550-50 3 x 400 V ± 10 % 55-5 5-100 105 138 600p 1500p 300p 120 Q3A/50-900 3 x 400 V ± 10 % 5-90 100-125 138 185 600p 100p 400p 150 Q3A/900-1100 3 x 400 V ± 10 % 90-110 125-150 15 210 800p 1900p 400p 150 Q3A/1100-1320 3 x 400 V ± 10 % 110-132 150-180 210 260 800p 1900p 400p 200 Q3A/1320-1600 3 x 400 V ± 10 % 132-160 180-218 250 305 800p 1900p 400p 200 Q3A/1600-2000 3 x 400 V ± 10 % 160-200 218-23 290 400 800p 1900p 400p 230 Q3A/2000-2500 3 x 400 V ± 10 % 200-250 23-340 400 460 1000p 1900p 400p 230 Q3A/2500-3150 3 x 400 V ± 10 % 250-315 340-430 450 580 1000p 1900p 400p 250 Dimensions note : P indicates floor mounted control panel. CB-Q3A-en_c_te 533

Q3D Series Three-phase electric panels for the protection and control of a 4 three-phase surface or submersible pump. Manual control through A-0-M switch Automatic control through an external contactor Supply voltage: 3 x 400 V ±10% Frequency: 50/60 Hz Low voltage auxiliary circuit 24 Vac Power: 0.25 to 3 kw Direct starting Overload protection Protection: IP54 Ambient temperature: -5 to +40 C (limit specified by EN standard 60439-1) Maximum relative humidity: 50% at +40 C provided that no condensation occurs (limit specified by EN standard 60439-1) Wall mounted Metal enclosure Power - pump running - thermal overload - dry running indicator lights Ready for installation of dry-running control with float or pressure switch (available separately) Electronic protection module with electrodes can be fitted Optional accessories SLD series 24V level kit: Probe module for protection against dry running (set of three electrodes included in the supply) Float switch Pressure switch VR3/SCA3 three-phase module for overvoltage protection (lightning protector) For proper electric panel-electric pump selection, make sure that the Ampere input of the motor falls within the rated current range shown in the table. 534

0 25 0 150 200 Q3D SERIES A C 500 V 300 A L1-L2 L2-L3 L3-L1 50 0 B M 0 A PANEL TYPE RATED RATED RATED DIMENSIONS WEIGHT VOLTAGE POWER CURRENT A B C V kw HP A mm mm mm Kg Q3D/02-03 3 x 400 V ± 10 % 0,25-0,3 0,33-0,50 0,63 1 300 400 200 15 Q3D/03-05 3 x 400 V ± 10 % 0,3-0,55 0,5-0,5 1 1,6 300 400 200 15 Q3D/05-0 3 x 400 V ± 10 % 0,55-0,5 0,5-1 1,6 2,5 300 400 200 15 Q3D/0-15 3 x 400 V ± 10 % 0,5-1,5 1-2 2,5 4 300 400 200 15 Q3D/15-22 3 x 400 V ± 10 % 1,5-2,2 2-3 4 6,3 300 400 200 15 Q3D/22-40 3 x 400 V ± 10 % 2,2-4 3-5,5 6,3 10 300 400 200 15 Q3D/40-5 3 x 400 V ± 10 % 4-,5 5,5-10 10 16 300 400 200 15 Q3D/5-92 3 x 400 V ± 10 %,5-9,2 10-12,5 16 20 300 400 200 15 Q3D/92-110 3 x 400 V ± 10 % 9,2-11 12,5-15 20 25 300 400 200 20 Q3D/110-150 3 x 400 V ± 10 % 11-15 15-20 22 32 400 500 200 20 Q3D/150-185 3 x 400 V ± 10 % 15-18,5 20-25 28 40 400 500 200 20 Q3D/185-220 3 x 400 V ± 10 % 18,5-22 25-30 36 50 400 600 200 2 Q3D/220-300 3 x 400 V ± 10 % 22-30 30-40 45 63 400 600 200 2 Q3D/300-30 3 x 400 V ± 10 % 30-3 40-50 5 5 400 600 200 2 CB-Q3D_a_te 535

Q3Y Series Three-phase electric panels for the protection and control of a 4 three-phase surface or submersible pump. Manual control through A-0-M switch Automatic control through an external contactor Supply voltage: 3 x 400 V ±10% Frequency: 50/60 Hz Low voltage auxiliary circuit 24 Vac Power: 4 to 315 kw Star-delta starting Overload protection Protection: IP54 Ambient temperature: -5 to +40 C (limit specified by EN standard 60439-1) Maximum relative humidity: 50% at +40 C provided that no condensation occurs (limit specified by EN standard 60439-1) Wall mounted Metal enclosure Power - pump running - thermal overload - dry running indicator lights Ready for installation of dry-running control with float or pressure switch (available separately). Electronic protection module with electrodes can be fitted Optional accessories SLD series 24V level kit: Probe module for protection against dry running (set of three electrodes included in the supply) Float switch Pressure switch VR3/SCA3 three-phase module for overvoltage protection (lightning protector) For proper electric panel-electric pump selection, make sure that the Ampere input of the motor falls within the rated current range shown in the table. 536

0 25 0 150 200 Q3Y SERIES A C 500 V 300 A L1-L2 L2-L3 L3-L1 50 0 B M 0 A MODEL RATED RATED RATED DIMENSIONS WEIGHT VOLTAGE POWER CURRENT A B C V kw HP A mm mm mm Kg Q3Y/40-5 3 x 400 V ± 10 % 4-,5 5,5-10 10 16 400 600 200 23 Q3Y/5-92 3 x 400 V ± 10 %,5-9,2 10-12,5 16 20 400 600 200 23 Q3Y/92-110 3 x 400 V ± 10 % 9,2-11 12,5-15 20 25 400 600 200 23 Q3Y/110-150 3 x 400 V ± 10 % 11-15 15-20 22 32 400 600 200 23 Q3Y/150-185 3 x 400 V ± 10 % 15-18,5 20-25 28 40 400 600 200 23 Q3Y/185-220 3 x 400 V ± 10 % 18,5-22 25-30 36 50 500 00 200 32 Q3Y/220-300 3 x 400 V ± 10 % 22-30 30-40 45 63 500 00 200 32 Q3Y/300-30 3 x 400 V ± 10 % 30-3 40-50 5 5 600 800 250 68 Q3Y/30-450 3 x 400 V ± 10 % 3-45 50-60 0 90 600 800 250 80 Q3Y/450-550 3 x 400 V ± 10 % 45-55 60-5 80 108 600 900 250 80 Q3Y/550-50 3 x 400 V ± 10 % 55-5 5-100 105 138 600p 1300p 300p 109 Q3Y/50-900 3 x 400 V ± 10 % 5-90 100-125 138 185 600p 1300p 300p 109 Q3Y/900-1100 3 x 400 V ± 10 % 90-110 125-150 15 210 600p 1500p 300p 120 Q3Y/1100-1320 3 x 400 V ± 10 % 110-132 150-180 210 260 800p 100p 400p 130 Q3Y/1320-1600 3 x 400 V ± 10 % 132-160 180-218 250 305 800p 100p 400p 130 Q3Y/1600-2000 3 x 400 V ± 10 % 160-200 218-23 290 400 800p 1900p 400p 140 Q3Y/2000-2500 3 x 400 V ± 10 % 200-250 23-340 400 460 1000p 1900p 400p 180 Q3Y/2500-3150 3 x 400 V ± 10 % 250-315 340-430 450 580 1000p 1900p 400p 180 Dimensions note : P indicates floor mounted control panel. CB-Q3Y-en_c_te 53

Q3I Series Three-phase electric panels for the protection and control of a 4 three-phase surface or submersible pump. Manual control through A-0-M switch Automatic control through an external contactor Supply voltage: 3 x 400 V ±10% Frequency: 50/60 Hz Low voltage auxiliary circuit 24 Vac Power: 4 to 315 kw Impedance starting Overload protection Protection: IP54 Ambient temperature: -5 to +40 C (limit specified by EN standard 60439-1) Maximum relative humidity: 50% at +40 C provided that no condensation occurs (limit specified by EN standard 60439-1) Wall mounted Metal enclosure Power - pump running - thermal overload - dry running indicator lights Ready for installation of dry-running control with float or pressure switch (available separately) Electronic protection module with electrodes can be fitted Optional accessories SLD series 24V level kit: Probe module for protection against dry running (set of three electrodes included in the supply) Float switch Pressure switch VR3/SCA3 three-phase module for overvoltage protection (lightning protector) For proper electric panel-electric pump selection, make sure that the Ampere input of the motor falls within the rated current range shown in the table. 538

0 25 0 150 200 Q3I SERIES A C 500 V 300 A L1-L2 L2-L3 L3-L1 50 0 B M 0 A MODEL RATED RATED RATED DIMENSIONS WEIGHT VOLTAGE POWER CURRENT A B C V kw HP A mm mm mm Kg Q3I/40-5 3 x 400 V ± 10 % 4-,5 5,5-10 10 16 400 600 250 35 Q3I/5-92 3 x 400 V ± 10 %,5-9,2 10-12,5 16 20 400 600 250 35 Q3I/92-110 3 x 400 V ± 10 % 9,2-11 12,5-15 20 25 400 600 250 35 Q3I/110-150 3 x 400 V ± 10 % 11-15 15-20 22 32 500 00 250 50 Q3I/150-185 3 x 400 V ± 10 % 15-18,5 20-25 28 40 500 00 250 50 Q3I/185-220 3 x 400 V ± 10 % 18,5-22 25-30 36 50 500 00 250 50 Q3I/220-300 3 x 400 V ± 10 % 22-30 30-40 45 63 500 00 250 65 Q3I/300-30 3 x 400 V ± 10 % 30-3 40-50 5 5 500 00 250 65 Q3I/30-450 3 x 400 V ± 10 % 3-45 50-60 0 90 600 900 250 65 Q3I/450-550 3 x 400 V ± 10 % 45-55 60-5 80 108 600p 1300p 300p 100 Q3I/550-50 3 x 400 V ± 10 % 55-5 5-100 105 138 600p 1300p 300p 100 Q3I/50-900 3 x 400 V ± 10 % 5-90 100-125 138 185 600p 1500p 300p 100 Q3I/900-1100 3 x 400 V ± 10 % 90-110 125-150 15 210 800p 100p 400p 100 Q3I/1100-1320 3 x 400 V ± 10 % 110-132 150-180 210 260 800p 100p 400p 150 Q3I/1320-1600 3 x 400 V ± 10 % 132-160 180-218 250 305 800p 100p 400p 150 Q3I/1600-2000 3 x 400 V ± 10 % 160-200 218-23 290 400 800p 1900p 400p 160 Q3I/2000-2500 3 x 400 V ± 10 % 200-250 23-340 400 460 1000p 1900p 400p 180 Q3I/2500-3150 3 x 400 V ± 10 % 250-315 340-430 450 580 1000p 1900p 400p 200 Dimensions note : P indicates floor mounted control panel. CB-Q3I-en_c_te 539

Q3SF Series Three-phase electric panels for the protection and control of a 4 three-phase surface or submersible pump. Manual control through A-0-M switch Automatic control through an external contactor Supply voltage: 3 x 400 V ±10% Frequency: 50/60 Hz Low voltage auxiliary circuit 24 Vac Power: 5.5 to 110 kw Soft start with torque control Protection: IP54 Ambient temperature: -5 to +40 C (limit specified by EN standard 60439-1) Maximum relative humidity: 50% at +40 C provided that no condensation occurs (limit specified by EN standard 60439-1) Wall mounted Metal enclosure Dry running indicator light Power-running-failure indicator LEDs on starter keypanel 0-1 selector switch for activation of bypass contactor Ready for installation of dry-running control with float or pressure switch (available separately) Electronic protection module with electrodes can be fitted Static starter for gradual starting and stopping featuring keypanel with liquid crystal display Optional accessories SLD series 24V level kit: Probe module for protection against dry running (set of three electrodes included in the supply) Float switch Pressure switch VR3/SCA3 three-phase module for overvoltage protection (lightning protector) For proper electric panel-electric pump selection, make sure that the Ampere input of the motor falls within the rated current range shown in the table. 540

Q3SF SERIES PANEL TYPE RATED RATED RATED DIMENSIONS WEIGHT VOLTAGE POWER CURRENT A B C V kw HP A mm mm mm Kg Q3SF 5 3 x 400 V ± 10 % 5,5 -,5,5-10 8,5 1 400 600 250 35 Q3SF 150 3 x 400 V ± 10 % 9,2-15 12,5-20 15 30 500 00 250 40 Q3SF 220 3 x 400 V ± 10 % 18,5-22 25-30 28 45 500 00 250 40 Q3SF 300 3 x 400 V ± 10 % 30 40 42 60 600 900 300 90 Q3SF 30 3 x 400 V ± 10 % 3 50 55 5 600 900 300 90 Q3SF 450 3 x 400 V ± 10 % 45 60 0 85 600 900 300 90 Q3SF 550 3 x 400 V ± 10 % 55 5 80 110 600 900 300 90 Q3SF 590 3 x 400 V ± 10 % 59 80 105 125 600 900 300 90 Q3SF 50 3 x 400 V ± 10 % 5 100 120 142 600p 100p 400p 120 Q3SF 900 3 x 400 V ± 10 % 90 125 135 190 600p 100p 400p 120 Q3SF 1100 3 x 400 V ± 10 % 110 150 185 245 600p 100p 400p 120 Dimensions note : P indicates floor mounted control panel. CB-Q3SF_b_te 541

QDR Series Three-phase electric panels for the protection and control of a three-phase drainage pump. Automatic control through electromechanical floats Supply voltage: 3 x 400 V ±10% Frequency: 50/60 Hz Power: 0.36 to 9.2 kw Direct motor starting Protection: IP54 Ambient temperature: -5 to +40 C (limit specified by EN standard 60439-1) Maximum relative humidity: 50% at +40 C provided that no condensation occurs (limit specified by EN standard 60439-1) Wall mounted Metal enclosure Power, thermal overload, high level indicator lights Alarm reset button /TS version with stator thermal protection circuit /WD version with water control probe in oil bath and stator thermal protection Optional accessories Audible or visual signalling device, 12 Vdc 0.3 A max. (inside the electric panel there are two connection terminals) for high-level alarm VR3 three-phase module for overvoltage protection (lightning protector) For proper electric panel-electric pump selection, make sure that the Ampere input of the motor falls within the rated current range shown in the table. 542

QDR SERIES MODEL RATED RATED RATED DIMENSIONS WEIGHT VOLTAGE POWER CURRENT A B C V kw HP A mm mm mm Kg QDR/03 3 x 400 V ± 10 % 0,3 0,5 0,63 1 280 30 150 4,1 QDR/05 3 x 400 V ± 10 % 0,55 0,5 1 1,6 280 30 150 4,1 QDR/0 3 x 400 V ± 10 % 0,5 1 1,6 2,5 280 30 150 4,1 QDR/15 3 x 400 V ± 10 % 1,1 1,5 1,5 2 2,5 4 280 30 150 4,1 QDR/22 3 x 400 V ± 10 % 2,2 3 4 6,3 280 30 150 4,1 QDR/40 3 x 400 V ± 10 % 3 4 4 5,5 6,3 10 280 30 150 4,1 QDR/5 3 x 400 V ± 10 % 5,5,5,5 10 10 16 280 30 150 4,1 QDR/0/TS 3 x 400 V ± 10 % 0,5 1 1,6 2,5 280 30 150 4,5 QDR/15/TS 3 x 400 V ± 10 % 1,5 2 2,5 4 280 30 150 4,5 QDR/22/TS 3 x 400 V ± 10 % 2,2 3 4 6,3 280 30 150 4,5 QDR/0/WD 3 x 400 V ± 10 % 0,5 1 1,6 2,5 280 30 150 5 QDR/15/WD 3 x 400 V ± 10 % 1,5 2 2,5 4 280 30 150 5 QDR/22/WD 3 x 400 V ± 10 % 2,2 3 4 6,3 280 30 150 5 The /WD option also includes the /TS option. CB-QDR-en_c_te 543

QDR2 Series Three-phase electric panels for the protection and control of two three-phase drainage pumps. Automatic control through electromechanical floats Supply voltage: 3 x 400 V ±10% Frequency: 50/60 Hz Power: 0.3 to 9.2 kw Direct motor starting Protection: IP54 Ambient temperature: -5 to +40 C (limit specified by EN standard 60439-1) Maximum relative humidity: 50% at +40 C provided that no condensation occurs (limit specified by EN standard 60439-1) Wall mounted Metal enclosure Electronic board with power, overload, high-level alarm, pump on/off indicator lights Alarm reset button /TS version with stator thermal protection circuit /WD version with water control probe in oil bath and stator thermal protection Optional accessories Audible or visual signalling device, 12 Vdc 0.3 A max. (inside the electric panel there are two connection terminals) for high-level alarm VR3 three-phase module for overvoltage protection (lightning protector) Signal relay board kit (power, aut/man, on/off, overload, high level) For proper electric panel-electric pump selection, make sure that the Ampere input of the motor falls within the rated current range shown in the table. 544

QDR2 SERIES MODEL RATED RATED RATED DIMENSIONS WEIGHT VOLTAGE POWER CURRENT A B C V kw HP A mm mm mm Kg QDR2/03 3 x 400 V ± 10 % 0,3 0,5 0,63 1 260 380 150 9,4 QDR2/05 3 x 400 V ± 10 % 0,55 0,5 1 1,6 260 380 150 9,4 QDR2/0 3 x 400 V ± 10 % 0,5 1 1,6 2,5 260 380 150 9,4 QDR2/15 3 x 400 V ± 10 % 1,1 1,5 1,5 2 2,5 4 260 380 150 9,4 QDR2/22 3 x 400 V ± 10 % 2,2 3 4 6,3 260 380 150 9,4 QDR2/40 3 x 400 V ± 10 % 3 4 4 5,5 6,3 10 260 380 150 9,4 QDR2/5 3 x 400 V ± 10 % 5,5,5,5 10 10 16 260 380 150 9,4 QDR2/92 3 x 400 V ± 10 % 9,2 12,5 16 20 300 400 180 11 QDR2/0/TS 3 x 400 V ± 10 % 0,5 1 1,6 2,5 400 400 200 14 QDR2/15/TS 3 x 400 V ± 10 % 1,1 1,5 1,5 2 2,5 4 400 400 200 14 QDR2/22/TS 3 x 400 V ± 10 % 2,2 3 4 6,3 400 400 200 14 QDR2/0/WD 3 x 400 V ± 10 % 0,5 1 1,6 2,5 400 500 200 18 QDR2/15/WD 3 x 400 V ± 10 % 1,1 1,5 1,5 2 2,5 4 400 500 200 18 QDR2/22/WD 3 x 400 V ± 10 % 2,2 3 4 6,3 400 500 200 18 The /WD option also includes the /TS option. CB-QDR2-en_b_te 545

QDRM Series Single-phase electric panels for the protection and control of a single-phase drainage pump. Automatic control through electromechanical floats Supply voltage: 1 x 230 V ±10% Frequency: 50/60 Hz Power: 0.25 to 2.2 kw Direct motor starting Protection: IP54 Ambient temperature: -5 to +40 C (limit specified by EN standard 60439-1) Maximum relative humidity: 50% at +40 C provided that no condensation occurs (limit specified by EN standard 60439-1) Wall mounted Metal enclosure Power, thermal overload, high level indicator lights Alarm reset button Optional accessories Audible or visual signalling device, 12 Vdc 0.3 A max. (inside the electric panel there are two connection terminals) for high-level alarm VR1 single-phase module for overvoltage protection (lightning protector) For proper electric panel-electric pump selection, make sure that the Ampere input of the motor falls within the rated current range shown in the table. 546

QDRM SERIES MODEL RATED RATED RATED DIMENSIONS WEIGHT VOLTAGE POWER CURRENT A B C V kw HP A mm mm mm Kg QDRM/02 1 x 230 V ± 10 % 0,25 0,33 1 1,6 280 220 160 2,2 QDRM/03 1 x 230 V ± 10 % 0,3 0,5 1,6 2,5 280 220 160 2,2 QDRM/05 1 x 230 V ± 10 % 0,55 0,5 2,5 4 280 220 160 2,2 QDRM/0 1 x 230 V ± 10 % 0,5 1 4 6,3 280 220 160 2,2 QDRM/15 1 x 230 V ± 10 % 1,1 1,5 1,5 2 6,3 10 280 220 160 2,2 QDRM/22 1 x 230 V ± 10 % 2,2 3 10 16 280 30 160 4,1 CB-QDRM-en_c_te 54

QDRMC Series Single-phase electric panels for the protection and control of a single-phase drainage pump with external capacitor. Automatic control through electromechanical floats Supply voltage: 1 x 230 V ±10% Frequency: 50/60 Hz Power: 0.5 to 2.2 kw Direct motor starting Protection: IP54 Ambient temperature: -5 to +40 C (limit specified by EN standard 60439-1) Maximum relative humidity: 50% at +40 C provided that no condensation occurs (limit specified by EN standard 60439-1) Wall mounted Plastic enclosure Power, thermal overload, high level indicator lights Alarm reset button Run and start capacitor in panel/ts version with stator thermal protection circuit/wd version with water control probe in oil bath and stator thermal protection Optional accessories Audible or visual signalling device, 12 Vdc 0.3 A max. (inside the electric panel there are two connection terminals) for high-level alarm VR1 single-phase module for overvoltage protection (lightning protector) For proper electric panel-electric pump selection, make sure that the Ampere input of the motor falls within the rated current range shown in the table. 548

QDRMC SERIES MODEL RATED RATED RATED DIMENSIONS WEIGHT C Cs VOLTAGE POWER CURRENT A B C V kw HP A mm mm mm Kg uf uf QDRMC/0 1 x 230 V ± 10 % 0,5 1 4 6,3 280 30 160 3,1 20 40 QDRMC/15 1 x 230 V ± 10 % 1,5 2 6,3 10 280 30 160 3,1 35 60 QDRMC/22 1 x 230 V ± 10 % 2,2 3 10 16 280 30 160 3,1 35 60 QDRMC/0/TS 1 x 230 V ± 10 % 0,5 1 4 6,3 280 30 160 3,5 20 40 QDRMC/15/TS 1 x 230 V ± 10 % 1,5 2 6,3 10 280 30 160 3,5 35 60 QDRMC/22/TS 1 x 230 V ± 10 % 2,2 3 10 16 280 30 160 3,5 35 60 QDRMC/0/WD 1 x 230 V ± 10 % 0,5 1 4 6,3 280 30 160 4 20 40 QDRMC/15/WD 1 x 230 V ± 10 % 1,5 2 6,3 10 280 30 160 4 35 60 QDRMC/22/WD 1 x 230 V ± 10 % 2,2 3 10 16 280 30 160 4 35 60 QDRMC/15/TS/GL 1 x 230 V ± 10 % 1,5 2 6,3 10 280 30 160 4 35 100 C= Run capacitor; Cs= Start capacitor CB-QDRMC-en_e_te 549

QDRM2 Series Single-phase electric panels for the protection and control of two single-phase drainage pumps. Automatic control through electromechanical floats Supply voltage: 1 x 230 V ±10% Frequency: 50/60 Hz Power: 0.25 to 2.2 kw Direct motor starting Protection: IP54 Ambient temperature: -5 to +40 C (limit specified by EN standard 60439-1) Maximum relative humidity: 50% at +40 C provided that no condensation occurs (limit specified by EN standard 60439-1) Wall mounted Metal enclosure Electronic board with power, overload, high-level alarm, pump on/off indicator lights Alarm reset button Optional accessories Audible or visual signalling device, 12 Vdc 0.3 A max. (inside the electric panel there are two connection terminals) for high-level alarm VR1 single-phase module for overvoltage protection (lightning protector) Signal relay board kit (power, aut/man, on/off, overload, high level) For proper electric panel-electric pump selection, make sure that the Ampere input of the motor falls within the rated current range shown in the table. 550

QDRM2 SERIES PANEL TYPE RATED RATED RATED DIMENSIONS WEIGHT VOLTAGE POWER CURRENT A B C V kw HP A mm mm mm Kg QDRM2/02 1 x 230 V ± 10 % 0,25 0,33 1 1,6 260 380 150 9,4 QDRM2/03 1 x 230 V ± 10 % 0,3 0,5 1,6 2,5 260 380 150 9,4 QDRM2/05 1 x 230 V ± 10 % 0,55 0,5 2,5 4 260 380 150 9,4 QDRM2/0 1 x 230 V ± 10 % 0,5 1 4 6,3 260 380 150 9,4 QDRM2/15 1 x 230 V ± 10 % 1,1 1,5 1,5 2 6,3 10 260 380 150 9,4 QDRM2/22 1 x 230 V ± 10 % 2,2 3 10 16 260 380 150 9,4 CB-QDRM2_a_te 551

QDRMC2 Series Single-phase electric panels for the protection and control of two single-phase drainage pumps with external capacitor. Automatic control through electromechanical floats Supply voltage: 1 x 230 V ±10% Frequency: 50/60 Hz Power: 0.5 to 2.2 kw Direct motor starting Protection: IP54 Ambient temperature: -5 to +40 C (limit specified by EN standard 60439-1) Maximum relative humidity: 50% at +40 C provided that no condensation occurs (limit specified by EN standard 60439-1) Wall mounted Plastic enclosure Electronic board with power, overload, high-level alarm, pump on/off indicator lights Alarm reset button Run and start capacitor in panel /TS version with stator thermal protection circuit /WD version with water control probe in oil bath and stator thermal protection Optional accessories Audible or visual signalling device, 12 Vdc 0.3 A max. (inside the electric panel there are two connection terminals) for high-level alarm VR1 single-phase module for overvoltage protection (lightning protector) Signal relay board kit (power, aut/man, on/off, overload, high level) For proper electric panel-electric pump selection, make sure that the Ampere input of the motor falls within the rated current range shown in the table. 552

QDRMC2 SERIES MODEL RATED RATED RATED DIMENSIONS WEIGHT C Cs VOLTAGE POWER CURRENT A B C V kw HP A mm mm mm Kg uf uf QDRMC2/0 1 x 230 V ± 10 % 0,5 1 4 6,3 390 40 130 8,5 20 40 QDRMC2/15 1 x 230 V ± 10 % 1,5 2 6,3 10 390 40 130 8,5 35 60 QDRMC2/22 1 x 230 V ± 10 % 2,2 3 10 16 390 40 130 8,5 35 60 QDRMC2/0/TS 1 x 230 V ± 10 % 0,5 1 4 6,3 390 40 130 9 20 40 QDRMC2/15/TS 1 x 230 V ± 10 % 1,5 2 6,3 10 390 40 130 9 35 60 QDRMC2/22/TS 1 x 230 V ± 10 % 2,2 3 10 16 390 40 130 9 35 60 QDRMC2/0/WD 1 x 230 V ± 10 % 0,5 1 4 6,3 390 40 130 10 20 40 QDRMC2/15/WD 1 x 230 V ± 10 % 1,5 2 6,3 10 390 40 130 10 35 60 QDRMC2/22/WD 1 x 230 V ± 10 % 2,2 3 10 16 390 40 130 10 35 60 QDRMC2/15/TS/GL 1 x 230 V ± 10 % 1,5 2 6,3 10 390 40 130 10 35 100 C = Run capacitor; Cs = Start capacitor. CB-QDRMC2-en_d_te 553

QGMC Series Single-phase electric panels for the protection and control of a single-phase drainage pump with external capacitor. Automatic control through external contact Supply voltage: 1 x 230 V ±10% Frequency: 50 Hz Power: 0.5 to 2.2 kw Direct motor starting Protection: IP55 Ambient temperature: -5 to +40 C (limit specified by EN standard 60439-1) Maximum relative humidity: 50% at +40 C provided that no condensation occurs (limit specified by EN standard 60439-1) Wall mounted Plastic enclosure Built-in run capacitor Built-in start capacitor Built-in starter Main switch with thermal protection For proper electric panel-electric pump selection, make sure that the Ampere input of the motor falls within the rated current range shown in the table. 554

QGMC SERIES PANEL TYPE RATED RATED RATED DIMENSIONS WEIGHT C Cs VOLTAGE POWER CURRENT A B C V kw HP A mm mm mm Kg F F QGMC/0 1 x 230 V ± 10 % 0,5 1 4 6,3 280 30 160 3 20 40 QGMC/15 1 x 230 V ± 10 % 1,5 2 6,3 10 280 30 160 3 35 60 QGMC/22 1 x 230 V ± ±10 % 2,2 3 10 16 280 30 160 3 35 60 C = Run capacitor; Cs = Start capacitor. CB-QGMC_a_te 555

QYR Series Three-phase electric panels for the protection and control of a three-phase drainage pump with star-delta starting. VR3 (for QDR) three-phase module for overvoltage protection (lightning protector) Automatic control through electromechanical floats Supply voltage: 3 x 400 V ±10% Frequency: 50/60 Hz Power: 3 to 5 kw Star-delta starting Protection: IP54 Ambient temperature: -5 to +40 C (limit specified by EN standard 60439-1) Maximum relative humidity: 50% at +40 C provided that no condensation occurs (limit specified by EN standard 60439-1) Wall mounted Metal enclosure Power, thermal overload, high level indicator lights Alarm reset button /TS version with stator thermal protection circuit /WD version with water control probe in oil bath and stator thermal protection Optional accessories Audible or visual signalling device, 12 Vdc 0.3 A max. (inside the electric panel there are two connection terminals) for high-level alarm For proper electric panel-electric pump selection, make sure that the Ampere input of the motor falls within the rated current range shown in the table. 556

QYR SERIES MODEL RATED RATED RATED DIMENSIONS WEIGHT VOLTAGE POWER CURRENT A B C V kw HP A mm mm mm Kg QYR/40 3 x 400 V ± 10 % 3 4 4 5,5 6,3 10 400 500 200 25 QYR/5 3 x 400 V ± 10 % 5,5,5.5 10 10 16 400 500 200 25 QYR/92 3 x 400 V ± 10 % 9,2 12,5 16 20 400 500 200 25 QYR/110 3 x 400 V ± 10 % 11 15 20 25 400 500 200 25 QYR/150 3 x 400 V ± 10 % 15 20 22 32 400 600 200 2 QYR/185 3 x 400 V ± 10 % 18,5 25 28 40 400 600 200 2 QYR/220 3 x 400 V ± 10 % 22 30 36 50 500 00 200 32 QYR/300 3 x 400 V ± 10 % 30 40 45 63 500 00 200 32 QYR/30 3 x 400 V ± 10 % 3 50 5 5 600 800 250 32 QYR/450 3 x 400 V ± 10 % 45 60 0 90 600 800 250 32 QYR/550 3 x 400 V ± 10 % 55 5 80 108 600 900 250 3 QYR/50 3 x 400 V ± 10 % 5 100 105 138 600p 1300p 300p 0 QYR/22/TS 3 x 400 V ± 10 % 2,2 3 4 6,3 400 500 200 25 QYR/40/TS 3 x 400 V ± 10 % 3 4 4 5,5 6,3 10 400 500 200 26 QYR/5/TS 3 x 400 V ± 10 % 5,5,5,5 10 10 16 400 500 200 26 QYR/92/TS 3 x 400 V ± 10 % 9,2 12,5 16 20 400 500 200 26 QYR/110/TS 3 x 400 V ± 10 % 11 15 20 25 400 500 200 26 QYR/150/TS 3 x 400 V ± 10 % 15 20 22 32 400 600 200 2 QYR/185/TS 3 x 400 V ± 10 % 18,5 25 28 40 400 600 200 2 QYR/220/TS 3 x 400 V ± 10 % 22 30 36 50 500 00 200 32 QYR/300/TS 3 x 400 V ± 10 % 30 40 45 63 500 00 200 32 QYR/30/TS 3 x 400 V ± 10 % 3 50 5 5 600 800 250 33 QYR/450/TS 3 x 400 V ± 10 % 45 60 0 90 600 800 250 33 QYR/550/TS 3 x 400 V ± 10 % 55 5 80 108 600 900 250 3 QYR/50/TS 3 x 400 V ± 10 % 5 100 105 138 600p 1300p 300p 0 QYR/40/WD 3 x 400 V ± 10 % 3 4 4 5,5 6,3 10 400 500 200 26 QYR/5/WD 3 x 400 V ± 10 % 5,5,5,5 10 10 16 400 500 200 26 QYR/92/WD 3 x 400 V ± 10 % 9,2 12,5 16 20 400 500 200 26 QYR/110/WD 3 x 400 V ± 10 % 11 15 20 25 400 500 200 26 QYR/150/WD 3 x 400 V ± 10 % 15 20 22 32 400 600 200 28 QYR/185/WD 3 x 400 V ± 10 % 18,5 25 28 40 400 600 200 28 QYR/220/WD 3 x 400 V ± 10 % 22 30 36 50 500 00 200 33 QYR/300/WD 3 x 400 V ± 10 % 30 40 45 63 500 00 200 33 QYR/30/WD 3 x 400 V ± 10 % 3 50 5 5 600 800 250 33 QYR/450/WD 3 x 400 V ± 10 % 45 60 0 90 600 800 250 33 QYR/550/WD 3 x 400 V ± 10 % 55 5 80 108 600 900 250 38 QYR/50/WD 3 x 400 V ± 10 % 5 100 105 138 600p 1300p 300p 1 Dimensions: p = floor-standing cabinet. CB-QYR-en_e_te 55

QYR2 Series Three-phase electric panels for the protection and control of two three-phase drainage pumps with star-delta starting. Automatic control through electromechanical floats Supply voltage: 3 x 400 V ±10% Frequency: 50/60 Hz Power: 3 to 5 kw Star-delta starting Protection: IP54 Ambient temperature: -5 to +40 C (limit specified by EN standard 60439-1) Maximum relative humidity: 50% at +40 C provided that no condensation occurs (limit specified by EN standard 60439-1) Wall mounted Metal enclosure Electronic board with power, overload, high-level alarm, pump on/off indicator lights Alarm reset button /TS version with stator thermal protection circuit /WD version with water control probe in oil bath and stator thermal protection Optional accessories Audible or visual signalling device, 12 Vdc 0.3 A max. (inside the electric panel there are two connection terminals) for high-level alarm VR3 three-phase module for overvoltage protection (lightning protector) Signal relay board kit (power, aut/man, on/off, overload, high level) For proper electric panel-electric pump selection, make sure that the Ampere input of the motor falls within the rated current range shown in the table. 558

QYR2 SERIES MODEL RATED RATED RATED DIMENSIONS WEIGHT VOLTAGE POWER CURRENT A B C V kw HP A mm mm mm Kg QYR2/40 3 x 400 V ± 10 % 3 4 4 5,5 6,3 10 500 00 200 55 QYR2/5 3 x 400 V ± 10 % 5,5,5,5 10 10 16 500 00 200 55 QYR2/92 3 x 400 V ± 10 % 9,2 12,5 16 20 500 00 200 55 QYR2/110 3 x 400 V ± 10 % 11 15 20 25 500 00 200 55 QYR2/150 3 x 400 V ± 10 % 15 20 22 32 600 800 250 68 QYR2/185 3 x 400 V ± 10 % 18,5 25 28 40 600 800 250 68 QYR2/220 3 x 400 V ± 10 % 22 30 36 50 600 900 250 5 QYR2/300 3 x 400 V ± 10 % 30 40 45 63 600 900 250 5 QYR2/30 3 x 400 V ± 10 % 3 50 5 5 600p 1300p 300p 92 QYR2/450 3 x 400 V ± 10 % 45 60 0 90 800p 100p 300p 125 QYR2/550 3 x 400 V ± 10 % 55 5 80 108 800p 100p 300p 125 QYR2/50 3 x 400 V ± 10 % 5 100 105 138 800p 1900p 300p 148 QYR2/22/TS 3 x 400 V ± 10 % 2,2 3 4 6,3 500 00 200 55 QYR2/40/TS 3 x 400 V ± 10 % 3 4 4 5,5 6,3 10 500 00 200 55 QYR2/5/TS 3 x 400 V ± 10 % 5,5,5,5 10 10 16 500 00 200 55 QYR2/92/TS 3 x 400 V ± 10 % 9,2 12,5 16 20 500 00 200 55 QYR2/110/TS 3 x 400 V ± 10 % 11 15 20 25 500 00 200 55 QYR2/150/TS 3 x 400 V ± 10 % 15 20 22 32 600 800 250 68 QYR2/185/TS 3 x 400 V ± 10 % 18,5 25 28 40 600 800 250 68 QYR2/220/TS 3 x 400 V ± 10 % 22 30 36 50 600 900 250 5 QYR2/300/TS 3 x 400 V ± 10 % 30 40 45 63 600 900 250 5 QYR2/30/TS 3 x 400 V ± 10 % 3 50 5 5 600p 1300p 300p 92 QYR2/450/TS 3 x 400 V ± 10 % 45 60 0 90 800p 100p 300p 125 QYR2/550/TS 3 x 400 V ± 10 % 55 5 80 108 800p 100p 300p 125 QYR2/50/TS 3 x 400 V ± 10 % 5 100 105 138 800p 1900p 300p 148 QYR2/40/WD 3 x 400 V ± 10 % 3 4 4 5,5 6,3 10 500 00 200 55 QYR2/5/WD 3 x 400 V ± 10 % 5,5,5,5 10 10 16 500 00 200 55 QYR2/92/WD 3 x 400 V ± 10 % 9,2 12,5 16 20 500 00 200 55 QYR2/110/WD 3 x 400 V ± 10 % 11 15 20 25 500 00 200 55 QYR2/150/WD 3 x 400 V ± 10 % 15 20 22 32 600 800 250 68 QYR2/185/WD 3 x 400 V ± 10 % 18,5 25 28 40 600 800 250 68 QYR2/220/WD 3 x 400 V ± 10 % 22 30 36 50 600 900 250 5 QYR2/300/WD 3 x 400 V ± 10 % 30 40 45 63 600 900 250 5 QYR2/30/WD 3 x 400 V ± 10 % 3 50 5 5 600p 1300p 300p 92 QYR2/450/WD 3 x 400 V ± 10 % 45 60 0 90 800p 100p 300p 125 QYR2/550/WD 3 x 400 V ± 10 % 55 5 80 108 800p 100p 300p 125 QYR2/50/WD 3 x 400 V ± 10 % 5 100 105 138 800p 1900p 300p 148 Dimensions: p = floor-standing cabinet. CB-QYR2-en_b_te 559

QXR20 Series Protection and control of two single-phase drainage pumps. Automatic control through electromechanical floats Power supply voltage: 1 x 230 V ±10% Frequency: 50/60 Hz Power: 0,25 to 1,5 kw Direct motor start Protection class: IP55 Ambient temperature: -5 to +40 C (according to EN 60439-1) Maximum relative humidity: 50% at +40 C, provided that no condensation occurs (according to EN 60439-1) Wall mounted Plastic enclosure Electronic board with power, thermal overload, acustic alarm of high level, pump, start/stop indicator LEDs Alarm silencing button Cyclic exchange starting pumps Aut-0-Man selector (1 for each pump) One pump is controlled by the closing of internal contact that is inside the control card Optional accessories Signal relay board kit (power, auto man, start/stop, thermal overload, high level) For proper electric panel-electric pump selection, make sure that the Ampere input of the motor falls within the rated current range shown in the table. 560

QXR20 SERIES MODEL RATED RATED RATED DIMENSIONS WEIGHT VOLTAGE POWER CURRENT A B C V kw HP A mm mm mm Kg QXR20 1 x 230 V ± 10 % 0,25 1,5 0,33 2 1 10 205 220 160 1,5 CB-QXR20-en_a_te 561

QCL5 Series Level control panel. Accessory for electric pump control panels, suitable for tank filling or drainage applications or for activation of sound or visual alarms. Automatic control through probes Power supply: 1 x 230 V ±10% o 1 x 24 V ±10% Frequency: 50/60 Hz Voltage to probes: 15 Vac at 0.5 ma max. Switch contact: 48 Vac at 3 A max. (250 W max.) Protection: IP55 Ambient temperature: -5 to +40 C (limit specified by EN standard 60439-1) Maximum relative humidity: 50% at +40 C provided that no condensation occurs (limit specified by EN standard 60439-1) Wall mounted Plastic enclosure Electrodes suitable for water at a maximum temperature of 40 C Set of three electrodes included in supply Optional accessories Drop cable with circular cross-section For connecting electrodes to the panel, the following cross-sections are recommended: PANEL TYPE m CABLE CROSS SECTION mm 2 0 50 0,5 50 100 0,8 100 200 1,0 200 400 2,5 400 > 4,0 CB-CASEL_a_te Three-pole cables can be used for short lengths. Otherwise, one-pole cables placed at suitable distances from each other should be used to prevent the capacitive effect of the cable from interfering with the proper operation of the electronic module. For proper electric panel-electric pump selection, make sure that the Ampere input of the motor falls within the rated current range shown in the table. 562

QCL5 SERIES PANEL TYPE POWER INPUT CONTACTS DIMENSIONS WEIGHT TENSION FREQUENCY POWER PANEL TYPE DELIVERY A x B x C V Hz W V A mm Kg QCL5/24 1 x 24 50/60 2 QCL5/230 1 x 230 50/60 2 NO-C-NC 48 3 90 x 130 x 60 0,5 CB-QCL5_a_te 563

QCL10 Series Level control panel. Accessory for electric pump control panels, suitable for tank filling or drainage applications or for activation of sound or visual alarms. Automatic control through probes Power supply: 1 x 230 V ±10% o 1 x 24 V ±10% Frequency: 50/60 Hz Voltage to probes: 15 Vac at 0.5 ma max. Protection: IP55 Ambient temperature: -5 to +40 C (limit specified by EN standard 60439-1) Maximum relative humidity: 50% at +40 C provided that no condensation occurs (limit specified by EN standard 60439-1) Wall mounted Plastic enclosure Electrodes suitable for water at a maximum temperature of 40 C Set of three electrodes included in supply Optional accessories Drop cable with circular cross-section For connecting electrodes to the panel, the following cross-sections are recommended: PANEL TYPE m CABLE CROSS SECTION mm 2 0 50 0,5 50 100 0,8 100 200 1,0 200 400 2,5 400 > 4,0 CB-CASEL_a_te Three-pole cables can be used for short lengths. Otherwise, one-pole cables placed at suitable distances from each other should be used to prevent the capacitive effect of the cable from interfering with the proper operation of the electronic module. For proper electric panel-electric pump selection, make sure that the Ampere input of the motor falls within the rated current range shown in the table. 564

QCL10 SERIES PANEL TYPE POWER INPUT CONTACTOR DIMENSIONS WEIGHT MAIN SECONDARY CLASS DELIVERY A x B x C V V V A mm Kg QCL10/24 1x230 50/60 Hz 1x 24 50/60 Hz QCL10/230 1x230 50/60 Hz - AC3 230 9 10 x 10 x 130 1 CB-QCL10_a_te 565

QCLP10 Series Level control panel. Accessory for electric pump control panels, suitable for tank filling or drainage applications or for activation of sound or visual alarms. Automatic control through probes Power input: 1 x 230 V ±10% o 1 x 24 V ±10% Frequency: 50/60 Hz Voltage to probes: 15 Vac at 0.5 ma max. Protection: IP55 Ambient temperature: -5 to +40 C (limit specified by EN standard 60439-1) Maximum relative humidity: 50% at +40 C provided that no condensation occurs (limit specified by EN standard 60439-1) Wall mounted Plastic enclosure with clear door enabling access to the magnetothermal switch Electrodes suitable for water at a maximum temperature of 40 C Set of three electrodes included in supply Optional accessories Drop cable with circular cross-section For connecting electrodes to the panel, the following cross-sections are recommended: PANEL TYPE m CABLE CROSS SECTION mm 2 0 50 0,5 50 100 0,8 100 200 1,0 200 400 2,5 400 > 4,0 CB-CASEL_a_te Three-pole cables can be used for short lengths. Otherwise, one-pole cables placed at suitable distances from each other should be used to prevent the capacitive effect of the cable from interfering with the proper operation of the electronic module. For proper electric panel-electric pump selection, make sure that the Ampere input of the motor falls within the rated current range shown in the table. 566

QCLP10 SERIES PANEL TYPE POWER INPUT CONTACTOR MAGNETOTHERMAL DIMENSIONS WEIGHT MAIN SECONDARY CLASS DELIVERY SWITCH A x B x C V V V A mm Kg QCLP10/24 1x230 50/60 Hz 1x 24 50/60 Hz AC3 230 9 C 10A Icn 6 KA 10 x 10 x 100 1,5 QCLP10/230 1x230 50/60 Hz - CB-QCLP10_a_te 56

KSL Series Accessory for electric panels. Electronic module for use of probes as protection against dry running Supply voltage: 1 x 24 V ±10% for model SLD/24 Frequency: 50/60 Hz Absorbed power: 3,5 VA max Voltage to probes:,5 V AC at 0,4 ma max Switch contact 24 V AC at 5 A max (250 W max) Designed for installation on Lowara electric panels featuring DIN bar Electrodes suitable for water at a maximum temperature of 60 C Optional accessories Module made of plastic material with DIN bar attachment Cables with quick plug-in connectors Set of three electrodes included in the supply Electrodes with nylon 6 body, stainless steel sensitive element brass washer and nitrile rubber seal Optional accessories Drop cable with circular cross section. For connection of the electrodes to the panel we recommend the following cross sections: PANEL TYPE CABLE CROSS SECTION m mm 2 0 50 0,5 50 100 0,8 100 200 1,0 200 400 2,5 400 > 4,0 CB-CASEL_a_te Three-pole cables can be used for short lenghts. Otherwise we recommend the use of unipolar cables placed at suitable distance from each other to prevent the capacitive effect of the cable from interfering with the proper operation of the electronic module. TYPE POWER SUPPLY CONTACT DIMENSIONS WEIGHT PANELS MAIN POWER TYPE RANGE A x B x C V VA V~ A mm Kg KIT KSL/24 1x24 50/60 Hz 3,5 N0-C-NC 250 8 90 x 36 x 60 0,5 QSCS-QM-QTD-Q3D-Q3Y- Q3A-Q3I-Q3SF CB-SLD-en_b_te For proper electric panel-electric pump selection, make sure that the Ampere input of the motor falls within the rated current range shown in the table. 568

DPF, VR, SCA3 Series Lightining protection. Accessory for electric panels. DPF SERIES Varistor for overvoltage protection of single-phase lines. To be connected between the phase and neutral conductor Operating voltage: 460 V AC Maximum varistor voltage: 50 V with 100 A peak current VR SERIES SCA3 SERIES Lightning arresters for overvoltage protection of three-phase lines. To be connected between the phases and the heart conductor Operating voltage: 500 V AC. Maximum varistor voltage: 2,5 kw with 40 ka peak current. Designed for installation on Lowara electric panels featuring DIN bar Varistors for overvoltage protection of three-phase lines To be connected between the phases (VR3 model) Operating voltage: 460 V AC Maximum varistor voltage: 50 V with 100 A peak current Designed for installation on Lowara electric panels featuring DIN bar DPF KIT VR1 KIT VR3 KIT SCA 3 TYPE VOLTAGE V 1 x 220-240 1 x 220-230 3 x 400 3 x 400 50/60 Hz 50/60 Hz 50/60 Hz 50/60 Hz PANELS QSM - QSC - QSCS - QPC QM - QDRM - QDRM2 - QDRMC - QDRMC2 QTD - QDR - QDR2 - Q3D Q3Y-Q3A-Q3I-Q3SF-Q3D CB-VR-en_c_te For proper electric panel-electric pump selection, make sure that the Ampere input of the motor falls within the rated current range shown in the table. 569