SmartWire Panel Wiring Solutions the easy way to connect



Similar documents
Number 1 in efficiency

Specifying a Variable Frequency Drive s

Modular I/O System Analog and Digital Interface Modules

PSR The compact range Description

40.3. Control Relays and Timers

SECTION LOW VOLTAGE LIGHTING CONTROLS

Phone: Fax: Web: info@clrwtr.com

Programmable set for Ethernet Modbus/TCP in IP67 TI-BL67-PG-EN-2

Using the AnyBus -X Gateway to Communicate between a DVT camera and a Profibus Master

SYSTEM 4C. C R H Electronics Design

L5354 ControlNet Communications Interface

TURCK Modular Industrial I/O PROFIBUS -DP Products

C441 series communication modules Accessories for electronic overload relays and soft starters. Monitoring and control made simple

PARAGON ELECTRIC, INC. LIQUID LEVEL CONTROLLER USER MANUAL MODELS: LLC-I, LLC-II AND TELEMETRY OPTIONS

G3 Series PROFIBUS DP Technical Manual

Whale 3. User Manual and Installation Guide. DC Servo drive. Contents. 1. Safety, policy and warranty Safety notes Policy Warranty.

THE INPUT/OUTPUT SYSTEM. Key Points

Electrical Symbols and Line Diagrams

INDUSTRIAL AUTOMATION EQUIPMENT EDITION

Vroom Hardware manual ver Code 114VROOHWE00. Vroom CANBUS USER INTERFACE WITH LCD GRAPHIC DISPLAY AND WITH TEMPERATURE AND HUMIDITY SENSOR

Install the DeviceNet Module using the following procedure:

BT300 HVAC Drives Conventional Bypass (C-Bypass) Options

Products and solutions for lifting systems

Automatic Transfer Switch FT-10 Network Control Communications Module (CCM-T) Kit

Repeaters and Mimics Data Sheet

AUTOMATIC TRANSFER SWITCH. Changeover Type from 250A to 2500A

Product Information. Gateway For Connecting EnDat Encoders to PROFIBUS-DP

2011, The McGraw-Hill Companies, Inc. Chapter 5


AN : Using Wago CANOpen IO

Advantium 2 Plus Alarm

SUBJECT: How to wire a motor starter Number: AN-MC-004 Date Issued: 2/08/2005 Revision: Original

ABB PSPS Erich Steinmann; Generator control-2013

Programming A PLC. Standard Instructions

SIMATIC S Getting Started for First Time Users. Order No.: 6ZB5310-0NC02-0BA0 04/2007 A5E

Using installed Fieldbus Wiring to carry Ethernet Communications

Data sheet GIOD.1 Input/output module with CAN bus. ERP no.: Data sheet GIOD.1 V_3.0

Permissible ambient temperature Operation Storage, transport

Arc Flash Avoidance and its Application to Overhead Traveling Cranes

PUSH BUTTON START INSTALLATION MANUAL

INSTALLATION INSTRUCTIONS

Practical steps for a successful. PROFIBUS Project. Presented by Dr. Xiu Ji Manchester Metropolitan University

POINTS POSITION INDICATOR PPI4

Square D Model 6 Motor Control Centers

In this section we tell you how to set the fault mode selection plug, key your I/O chassis, install your module and make your wiring connections.

ABB Drives. User s Manual. Pulse Encoder Interface Module RTAC-01

EDI Distributor Control Interface Wiring and Setup Instructions

know-how Giant in distributing electricity for industry Prisma GK

UL 508A Industrial Control Panels Power Distribution and Control. Lunch & Learn Training Eaton Corporation. All rights reserved.

OVR Three-Phase Recloser and PCD Control Style Guide 1VAL SG October 13, 2009 Revision F

CPB. Doc. N MO-0279-ING MODBUS/PROFIBUS DP CONVERTER TYPE CPB. Microener - Copyright 2010 Date Rev. 0

Controllers. The integrated standard software guarantees highest quality standards! Simple and safe operation. Specific and clear indication

IBS IP I/O Gateway. Data Sheet INTERBUS-S. Coupling Module for Two InterBus-S Lines

Fan Coil EC Motor Control

EXPERIMENT 2 TRAFFIC LIGHT CONTROL SYSTEM FOR AN INTERSECTION USING S7-300 PLC

SYSTEM 45. C R H Electronics Design

Temperature & Humidity SMS Alert Controller

ABB machinery drives. User s manual ACS355 drives

UniStream CPU-for-Panel

OPT SERIAL TO FIBER OPTIC CONVERTER

Chapter 5. Components, Symbols, and Circuitry of Air-Conditioning Wiring Diagrams

Introduction to the Actuator Sensor-Interface

MACHINEMATE. CNC SYSTEM Hardware SPECIFICATION

ABB general machinery drives. User s manual ACS355 drives

Franco Vecchiato, SAM LPBS Regional Manager New SACE Emax 2 From Circuit-breaker to Power Manager

Impulse G+/VG+ Series 3, 24 VDC Interface Card Terminal Designations

CMC-PD01 PROFIBUS DP Slave Communication Card Operation Manual

What ensures easy and fast wiring?

NC-12 Modbus Application

DeviceNet Communication Manual

Application Note AN-SERV-006

DeviceNet Bus Software Help for Programming an Allen Bradley Control System

Easily connect your switchboards to facility management solutions

INSTALLATION & SERVICE MANUAL. Display Panel

ZC-24DO CANopen I/O Module: 24 Digital Outputs

HydraPort 12 Module Connection Ports HPX-1200SL, Brushed Aluminum (FG SL) HPX-1200BL, Black Anodized (FG BL)

Control Box Wiring For PRSstandard Tool

EPLAN Electric P8 Basics for GM Course (Version 4.6, dated October, 2015) Course No. GCCE8023, (CTIS: 33090)

CutMaster Major External Replacement Parts

USER MANUAL CHARGING STATIONS FOR ELECTRIC VEHICLES

Options for ABB drives, converters and inverters. User s manual FDPI-02 diagnostics and panel interface

Siemens S7 PLC and FC 300 Profibus

R22. K Control. Indoor Unit. Nomenclature. Compatibility PL H 3 G K H B. Unit style Heat Pump Horse Power

MLC TM Maximum Productivity and Versatility for Control without Compromise!

Power Feeding Equipment for Optical Submarine Cable Systems

3BASIC RELAY INSTRUCTIONS

CAN BUS INTERFACE. Module Information

ISIO 200. Binary Input/Output (I/O) Terminal with IEC Interface

M-series Virtual I/O Module 2

Positive-guided relay outputs: 3 safety contacts (N/O), instantaneous. 1 auxiliary contact (N/C), instantaneous

applicomio Profibus-DP

Global Motion Technology Inc Web THCSA200. Capacitive sensor plasma & Oxy-fuel Torch Height Control

/ Instruction Manual. Analog Input/Output Interface Card "OPC-G1-AIO"

Quick Connect. quick - simple - efficient.

*.ppt 11/2/ :48 PM 1

Industrial Communication

Bussmann. All-In-One Module. Bussmann Power Module Switch. How to configure Part Numbers: Step 1: Select Switch Amperage 1

PROGRAMMABLE LOGIC CONTROL

Transcription:

SmartWire Panel Wiring Solutions the easy way to connect Richard Chung SmartWire Program Manager Milwaukee, WI 2008 Eaton Corporation. All rights reserved.

SmartWire Panel Wiring Solution Key Customer Needs Low cost connectivity to standard devices Easy method for connecting vs traditional hard-wiring Cost and time savings during assembly, test, and commissioning i i Reduced overall footprint of control panel layout Easy connectivity to industry standard logic networks Traditional SmartWire Elimination of I/O modules Major reduction of control wiring 25% space savings in panel 2 2

SmartWire Panel Wiring Solutions 1) An Easy Way to Connect Components 2) Achieve PLC Independence 3) Quicker Assembly Time 4) Prognostic Capability 5) Cost Savings 6) Quicker Commissioning i i 3 3

Why did we develop SmartWire? Past and today Wiring of a control cabinet is a labor-intensive activity Every wire has to be... Cut to length Stripped of insulation Crimped with ferrule or lugs (sometimes) Tagged with wire-markers Installed in wire duct SmartWire reduces control circuit wiring SmartWire saves panel space and time SmartWire connects to standard d control components SmartWire helps to error-proof control wiring 4 4

Traditional vs SmartWire Control Panel 5 5

Revolution in the control cabinet SmartWire Reduces design time Reduces the amount of control wiring Reduces time for wiring (up to 60%) Eliminates traditional PLC I/O and Remote I/O modules Reduces testing and commissioning time Reduces the complexity of wiring Makes it easy to troubleshoot 6 6

Revolution in the control cabinet SmartWire Reduces design time Reduces the amount of control wiring Reduces time for wiring (up to 60%) Eliminates traditional PLC I/O and Remote I/O modules Reduces testing and commissioning time Reduces the complexity of wiring Makes it easy to troubleshoot 7 7

System Overview 1 Gateway 2 Flat cable 1 3 XT CMCs 2 3 10 4 Power feed module 5 Discrete I/O module 4 7 11 12 6 Flat cable coupling 7 M22 pilot devices 8 Enclosure feed thru plug 5 6 8 9 9 Round cable 10 M22 control stations 11 XT contactors 12 Terminating resistor 8 8

Features SmartWire Feature Enables communication with standard components Technica al Features Can be used in and outside the cabinet Up to 99 nodes Up to 2000 feet (600 m) cable Easy to mount Automatic addressing of the nodes Communication to PLC field bus via gateway 1 2 3 99 2000 feet (600 m) 9 9

Assortment SmartWire Assortm ment Available 3Q in US Gateways (Profibus-DP, CANopen) One module for contactors up to 20HP (XT B & C frames) Function elements for M22 pilot devices Digital input and output modules Accessories 5HP 59% Motor Market Data 20HP 26% > 1000HP 0% 1000HP 0% 500HP 1% 200HP 2% 100HP 3% 50HP 9% 10 10

SmartWire - the easy way to connect Gateways EU5C-SWD-DP Profibus-DP Up to 58 SmartWire nodes Automatic baud rate detection up to 12MB Separate 24V supply for Gateway and ~ 30 SmartWire modules Contactors (24VDC max. 3A) Address setting by DIP Switch EU5C-SWD-CAN CANopen Up to 99 SmartWire nodes Automatic baud rate detection up to 1MB Separate 24V supply for Gateway and ~ 30 SmartWire modules Contactors (24VDC max. 3A) Address setting by DIP Switch Bus termination by DIP Switch 11 11

Mounting Place connector on flat cable Shift connector to final position Fix connector permanently with crimping tool Attach connector to module 12 12

SmartWire Flat Cable 13 13

Contactor Element Standard XT CMCs (combination motor controllers) are used SmartWire function elements are connected to contactors up to 20HP Features Powers the 24VDC contactor coil Provides feedback from the contactor Two additional inputs (e.g. trip, short circuit, additional auxiliary contact) Also available with Man-0-Auto switch for direct operation 14 14

M22 function elements front fixing Standard control and signaling devices remain unchanged M22-SWD function-elements are used instead of contact or LED elements Combinations of (multiple) contact elements and LED elements are replaced by one single powerful function element Control wiring is eliminated - connection to the SmartWire cable is realized by a SWD connector Function elements: 1 contact (NO/NC form C) 2 contact (NO/NC form C) LED - R,G,B or W 1 contact (NO/NC form C) with LED - R,G,B or W 2 contact (NO/NC form C) with LED - R,G,B or W 15 15

M22 function elements base fixing Standard M22 pilot devices and enclosures M22-SWD function elements are used instead of contact blocks or LED elements Combinations of (multiple) contact elements and LED elements are replaced by one powerful function element PCB M22-SWD-I* is used to adapt function elements to SWD Flexible interface to the SmartWire round cable Integrated terminating resistor in enclosure Function elements: 1 contact (NO/NC form C) 2 contact (NO/NC form C) LED - R,G,B or W 1 contact (NO/NC form C) with LED - R,G,B or W 2 contact (NO/NC form C) with LED - R,G,B or W 16 16

Input and Output Modules EU5E-SWD-8DX I/O modules to connect devices without integrated SmartWire interface EU5E-SWD-8DX 8 inputs EU5E-SWD-4D4D 4 inputs, 4 outputs 24V 0.5A EU5E-SWD-4D2R 4 inputs, 2 Relay, 3A Mounting on the desired place in the cabinet Remaining control wiring is further more reduced Direct control of contactors up to 60HP without auxiliary contactors EU5E-SWD-4D4D EU5E-SWD-4D2R 17 17

SmartWire Panel Wiring Solution PLC Interface 1. Set gateway slave address & apply 24V power 2. Press configuration button Addressing of elements is done automatically 3. Connect gateway to PLC Commission network master/map gateway 4. Start PLC 1 2 3 4 5 6 7. 18 18

SWD-Assist simplifies planning of SmartWire networks Graphical planning tool for SmartWire networks Calculation of power consumption and proposal for insertion of additional Power Feed module - Contactors (24V, 3A) - Network supply (15V, 0.7A) Syntax check Auto complete function adds missing SmartWire components Printout of SmartWire nodes with ordering information Stores project specific GSD file for direct use in PROFIBUS configuration tool 19 19

Benefits of SmartWire SmartWire Technology offers security and simplification Project: Reduction of wiring, I/O Modules (PLC), auxiliary contacts Less components to consider (Example: one M22-SWD function element replaces both LED light unit and contact block) Time saving (Less interfaces, components) Cost reduction (Less cables, components, space) Order / Delivery Less components to order / unpack Assembly Simplification of assembly Time saving due to elimination of control wiring Elimination of wiring test Service More diagnostics Simple replacement. All SWD nodes have a plug-in connector 20 20

Future: Function Element for PKE Electronic MMP COM-Module PKE-SWD-32 Maximum Current Thermal Capacity Overload Trip Indication Overload Short Circuit Phase Loss Overload Relay FLA Settings Overload Relay Class PKE On-Off Status Contactor On-Off Off Status 21 21

Benefits & Advantages of SmartWire Technology SmartWire can provide lean business solutions SmartWire make your control panels PLC independent SmartWire was designed to connect to device level controls economically and mechanically SmartWire connects to standard control components 22 22

Don t get left behind...get SmartWire! 23 23

SmartWire Value Message OFFERING Gateways Profibus-DP & CANopen XT contactor modules M22 pilot device modules Discrete I/O modules Flat and round cables Crimp tools and accessories EtherNet/IP gateway (coming) Analog I/O modules (coming) POINTS OF DIFFERENCE An easy way to connect vs wire Low cost connectivity to standard devices On board 24VDC power for devices Elimination of PLC I/O modules and associated hard wired connections Up to 99 nodes per gateway adapter Up to 2000 ft long network VALUE Cost and time savings during assembly, test, and commissioning Reduced overall footprint of control panel layout Assembly and connection of components independent of PLC processor 24 24

25 25