Instruction / Installation Sheet DataComm Electronics 50-6623-WH-KIT Flat Panel TV Cable Organizer Kit with Duplex Power Solution



Similar documents
ORIGINAL CABLE PLATES

Installation Instructions

VS CONTROL PACK INSTALLATION INSTRUCTIONS

Generator Transfer Switch Model # HTS15-AUTO

Installation Instructions

Installation Instructions

Video Camera Installation Guide

BUILT-IN DISHWASHER INSTALLATION INSTRUCTIONS

12-Volt 10-Amp Regulated Power Supply

FUTURE CALL PICTURE CARE PHONE MODEL: FC-1007 USER MANUAL

Doorbell Intercom Security System

Table of Contents. What to Expect with. Preparation. Tools Needed. Wiring. Hanging the Fan. Blades. Motor Housing.

Cooktop Low-Profile Ventilation Hoods

Installation Instructions For Slider Casement Air Conditioners

1. SAFETY RULES. 8. Avoid placing objects in the path of the blades.

RC930 Manual 6/10/99 1:23 PM Page 1. Wireless Modem Jack

ECM-30 30A AC Power Module Spike Suppressor

Refer installation of power supplies to qualified service personnel.

54 LinkTM. Instruction Manual. Includes our new CoolTouch Control System Looks permanent, but goes wherever you go! U.S.

GUIDELINES FOR WIRING SINGLE FAMILY DWELLING UNITS

CortezTM A Kichler Décor Ceiling Fan

User Manual Door Camera

INSTALLATION INSTRUCTIONS

ANI Instruction Manual DIGITAL INDOOR/OUTDOOR TV ANTENNA OMNI-DIRECTIONAL WITH AMPLIFIER INTRODUCTION:

LED MOTION ACTIVATED FLOOD LIGHT

1. SAFETY RULES WARNING TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK OR PERSONAL INJURY, MOUNT FAN TO OUTLET BOX MARKED "ACCEPTABLE FOR FAN SUPPORT".

Wireless Alarm System. Panic Button. User s Manual. Choice ALERT. Control all sensors, accessories and remote transmitters from one location

PT-6000 Power Tower INSTALLATION MANUAL SPECIFICATIONS

HOME THEATER SYSTEM. Instruction Manual. Model ASR150. Please read the instruction manual carefully before using your unit.

HM-W536 Install Guide

RCR-22 AM/MW 2 bands Digital Clock Radio instruction manual

BeoLab 1. User s guide

5-Slot Housing and FrameSaver 9000 Series Access Carrier AC Power Supply Installation Instructions

Disabled Toilet Alarm. Contractor Pack. Installation & Operating Instructions

BUILT-IN MICROWAVE OVEN INSTALLATION INSTRUCTIONS

On/Off Relay Switch and 3-Way Switch Kit

INSTALLATION MANUAL ELECTRIC RANGE. Please read these instructions thoroughly before installing and operating the range.

Wireless Alarm System. Wireless Keypad. User s Manual. Choice ALERT. Control all sensors, accessories and remote transmitters from one location

GENERAL WIRING RULES FOR HOUSES

Pedestal Owner s Manual

B100. single-line business telephone

INSTALLATION AND OPERATING INSTRUCTIONS For Model GL1 Gate Locks

ELECTRICAL GUIDELINES FOR SINGLE-FAMILY HOME OWNERS:

IntelliBrite Controller (For IntelliBrite Pool, Spa and Landscape Lighting Fixtures) Installation and User s Guide

BOSE. Link AL8 HOMEWIDE WIRELESS AUDIO LINK

Arc Fault Circuit Interrupters Frequently Asked Questions

USE &CARE GUIDE. Remote Faucet Pump System. See Important Safeguards on page 2

ELECTRONICS G H I J K L M

Installation Instructions

OPL BASIC. Dosing System for Professional Laundry machines. Contents

2 Mega-Pixel PoE Plus Speed Dome Internet Camera ICA-HM620. Quick Installation Guide

SWITCH! DESCRIPTION. ENVIRONMENTAL SPECIFICATIONS Operating Temperature: 0 C to +40 C SPECIFICATION SHEET:

P150SC15. Designed for 2015 Ford F150 Super-Cab and Super-Crew vehicles without Sony System Stillwater Designs P150SC15-A

Pre-Fab Easy Installation For Models: 006-CT-USK, 008-CT-USK Installation and Operating Instructions for Existing Homes with Standard Piping

SNQ-60x0-320 Series Data Center Switch. Quick Installation Guide

Power surges can also be generated by equipment in your facility such as:

Arecont Vision H.264 Color or Day/Night SurroundVideo Series Installation Manual

Service Guide 12/27/03 TESTING, SERVICE & REPAIR GUIDE (For SH Space Heating Models & RA Water Heating Models)

Owners & Installation Manual for the Sheridan, Mountainair, Pine Valley and Old Forge Ceiling Fan Family

IMPORTANT INSTRUCTIONS & OPERATING MANUAL. Houston 50 Inch Electric Wall Mounted Fireplace Black / White

AMPSEAL* Automotive Plug Connector and Header Assembly

INSTALLATION GUIDE LOW VOLTAGE TRANSFORMER

LIEBERT VNSA Installation Sheet

Installation Instructions S

HP Laser Jet 4200/4240/4250/4300/4350 Swing Plate

Operation Manual. Multi Channel Power Amplifier DPA-430L

JANUS INTERNATIONAL CORPORATION INSTALLATION INSTRUCTIONS Pantheon Mini Operator

Movable Wall 8-Wire Base Electrical System - Product Notes

DIGITAL ALARM II FOR HOSPITALS AND LABORATORIES INSTALLATION AND OPERATING INSTRUCTIONS

Operating Instructions

HP Laser Jet 2400 Series Fixing Drive Side Plate Assembly Fixing Drive Side Plate Assembly- RM page 1

HP UPS R1500 Generation 3

IMPORTANT: BEFORE INSTALLING ANY HEATING TERMINAL UNIT TO A DOMESTIC WATER HEATER, CONSULT THE LOCAL PLUMBING CODES.

LUCCI AIRFUSION QUEST II CEILING FAN

Electrical for Detached Garages: Updated Feb 19, 2016 for 2015 CE Code in force Jan. 1, Underground branch circuit feeding a detached garage:

100 Series Maxi Internal Filters. Instruction Manual

=============================== WARNING

HOW TO INSTALL A BEAUTIFUL NEW KITCHEN

ELECTRIC CONVECTION BUILT-IN OVEN

3. SEISCO PARTS & SERVICE REMOVAL AND REPAIR GUIDE

FN2001-A1 Network module (SAFEDLINK) Mounting Installation

Electrical Safety Plugs What are the different types of plugs? Extension Cords What are some potential hazards involving extension cords?

Instructions for: TTW 1 Universal Service Replacement Blower Kit P/N

Composite Stone Veneer

OWNER S MANUAL DRAINVAC ATOMIK PRINTED APRIL

Anthro Tablet Charging Cabinets

SAN FRANCISCO. U.S. Patents: 5,951,253; 6,158,964; 6,171,060; 6,250,885 INSTRUCTION MANUAL WARRANTY CERTIFICATE

QUICK START GUIDE. Thank you for purchasing the ButtKicker Kit. This guide will help you quickly set up your new ButtKicker Kit Contents: BK-Kit-4

I nstallation. M100Q Series Proportional Actuator with R81Q Controller Board for Thermistor Sensor Applications. Tools Needed.

GENERAL ELECTRICAL REQUIREMENTS

Wireless Alarm System. Alarm Siren. User s Manual. Choice ALERT. Control all Sensors & accessories from one location

5.8GHz Audio/Video Sender

Introduction. Safety Guidelines. Part Numbers. Operation and Maintenance Manual. Operation and Maintenance Manual

3 IN 1 BATHROOM HEATER

WARNING: To prevent fire or electric shock, do not expose this appliance to rain or moisture.

Model #: SMART2200CRMXL

AutoRanging Digital MultiMeter

Installation and Troubleshooting Instructions for Electric Tankless Residential Water Heaters.

IMPACT ALARM SYSTEM FOR HOSPITALS AND LABORATORIES INSTALLATION AND OPERATING INSTRUCTIONS INTRODUCTION

Transcription:

Instruction / Installation Sheet DataComm Electronics 50-6623-WH-KIT Flat Panel TV Cable Organizer Kit with Duplex Power Solution DataComm Electronics, Inc. 6349 Peachtree Street Norcross, GA 30071-1725 770.662.8205 Parts Included: 1. Recessed Low Voltage Mid-Size Plate with Duplex Receptacle 2. Recessed Low Voltage Cable Plate with Straight Blade Inlet 3. Two (2) Electrical Outlet Boxes Four (4) Screws per Outlet Box 4. 15 Amp/125 Volt Tamper Resistant Duplex Receptacle 5. Three (3) Wire Nuts 6. 6ft. 16/2 with Ground Cord Set with 360 o Rotating Head 7. 8 Electrical Wire - Romex Tools Needed: 1. Drywall Saw 2. 6 Ft. Tape Measure 3. Pencil 4. Screwdriver Use the Flat Panel TV Cable Organizer Kit with Duplex Power Solution to install power and low voltage cables behind your flat panel TV, amplifier or other audio and video devices to your equipment room or at the location of your head end equipment (see Figures 1 & 2). Figure 1 Front View Figure 2 Back View IMPORTANT INSTRUCTIONS: Use the local electrical code approved installation when installing this product. The electrical parts in this kit are designed to be used only as a kit and none of these electrical parts are designed to be used individually. This product is not designed to be part of your home or a commercial building s electrical wiring system. This installation is only energized (electrically active) when the supplied 6 ft. cord is plugged into the recessed straight blade inlet located on the recessed low voltage cable plate and the straight blade end of the 6 ft. cord is plugged into either your surge protector or wall receptacle. If you are not familiar with home wiring systems, please call a qualified electrician to install this product. IMPORTANT INSTRUCTIONS: This product is designed for retrofit work only because the electrical outlet box cannot be attached to a stud. Installation Instructions for Retrofit Only: Select the location of your flat panel TV mounting bracket. Now select the location for both cable plates for the Flat Panel TV Cable Organizer Kit with Duplex Power Solution. Page 1 of 4 9/21/12

Installation / Instruction Sheet 50-6623-WH-KIT (Continued) www.datacommelectronics.com Installation Instructions for the Top Plate with Duplex Receptacle: Fig. 1 Figure 1 Top view - shows needed space between the drywall and the studs. Receptacle side of the Mid-Size Plate should be 3 from the stud but no more than 5 (review picture carefully). Fig. 2 Figure 2 Using the template supplied (see page 3 of instruction sheet), trace the opening needed. Using a drywall saw, cut a hole in the drywall the size of the template. See Figure 1 before tracing your opening. Remember, the plates are designed to be mounted between the studs. Fig. 3 Figure 3 Run the 14/2 w/ground UL approved electrical building wire (included in kit) from the top opening to the bottom opening and connect the Cable Plate with Duplex Receptacle to the Cable Plate with Straight Blade Inlet. Make sure the piece of wire is long enough to allow for easy installation of the receptacles. Remember the Flat Panel TV Cable Organizer Kit with Duplex Power Solution is not part of your home s electrical wiring system. Pull the building wire through a hole in the top cable plate electrical outlet box. Use a screwdriver to open one of the knock outs on the electrical outlet box. Fig. 4 Figure 4 Now pull the other end of the building wire through a hole in the bottom plate electrical outlet box. Use a screwdriver to open one of the knock outs on the electrical outlet box Fig. 5 Figure 5 Using the supplied duplex receptacle, connect the hot line (black) wire to the brass colored terminal or screw and the neutral (white) wire to the silver colored terminal or screw. Be sure to connect the grounding (green) or bare grounding wire to the green colored terminal screw. For shock protection, this UR, UL recognized component receptacle must be properly grounded. Caution use copper wire only with this receptacle. Once you have wired the receptacle, screw the receptacle into the electrical outlet box until the receptacle is firmly secured. Fig. 6 Figure 6 Now use the four screws provided to secure the electrical outlet box to the mounting studs on the backside of the Mid-Size Plate with Duplex Receptacle. Fig. 7 Figure 7 Stop: Important: Before installing the Recessed Mid-Size Plate with Duplex Receptacle into the template opening, make sure to pull your low voltage cables through the low voltage cable opening. If you have more than 4 cables you can remove the flexible plate that seals the low voltage cable opening. This allows for more cables to be pulled through the opening. After you have pulled your low voltage and A/V cables through the low voltage opening: Start with the bottom of the Recessed Mid-Size Plate with Duplex Receptacle and slowly slide the plate into the opening. Swing the top of the plate into position until the entire Mid-Size Plate is flush with the wall. Now screw down the screws with wings; these wings fasten tightly against the back of the drywall. Page 2 of 4 9/21/12

Installation / Instruction Sheet 50-6623-WH-KIT (Continued) Installation Instructions for the Bottom Cable Plate with Straight Blade Inlet Fig. 8 Figure 8 Wire the Cable Plate with Straight Blade Inlet to the supplied 14/2 w/ground UL approved electrical building wire. Connect the hot line (black) wire to the black wire and the neutral (white) wire to the white wire on the straight blade inlet. Be sure to connect the grounding (green) or bare grounding wire to the green wire on the straight blade inlet. Make sure the three wire nuts are fastened tightly. Fig. 9 Figure 9 Now use the four screws provided to secure the electrical outlet box to the mounting studs on the backside of the Cable Plate with Straight Blade Inlet. Fig. 10 Fig. 11 Figure 10 Important: Before installing the Plate with Straight Blade Inlet into the template opening, make sure to pull your low voltage cables through the low voltage cable opening. If you have more than 4 cables you can remove the flexible plate that seals the low voltage cable opening. This allows for more cables to be pulled through the opening. After you have pulled your low voltage or A/V voltage cables through the low voltage opening: Start with the side of the Plate with Straight Blade Inlet and slowly slide the plate into the opening. Swing the right side of the plate into position until the entire plate is flush with the wall. Now screw down the screws with wings; these wings fasten tightly against the back of the drywall. Figure 11 Your new Flat Panel TV Cable Organizer Kit with Duplex Power Solution is now installed and ready for the flat panel TV mount to be installed. Install your flat panel TV mounting bracket per the flat panel TV bracket manufacturer s instruction. Fig. 12 Figure 12 Hang your flat panel TV on the mounting bracket and plug your TV into the top Cable Plate with Duplex Receptacle. Now plug your cord set into bottom Cable Plate with Straight Blade Inlet. Then plug the male end of the cord set into a nearby wall receptacle. WARNING DataComm Electronics products shall be installed and used only as indicated in DataComm Electronics product instruction sheets. Instruction sheets are available online at. CAUTION For shock protection, this device must be properly grounded. Use copper wire only with this device. IMPORTANT INSTRUCTIONS Read and understand all instructions. Follow all warnings and instructions marked on the product. Do not use this product near water, for example near a bath tub, wash bowl, kitchen sink, laundry tub, in a wet basement, or near a swimming pool. SAVE THESE INSTRUCTIONS. This product is patent protected by U.S. Patent numbers D553475, D554475 and 7390964. RoHS Compliant. Page 3 of 4 9/21/12

Installation / Instruction Sheet 50-6623-WH-KIT (Continued) ONLY LICENSED PROFESSIONALS SHOULD INSTALL THIS PRODUCT 6-1/2 TEMPLATE 4-1/2 Recessed Low Voltage Mid-Size Plate with Duplex Receptacle ACTUAL SIZE CUT ALONG DOTTED LINE 4-11/16 TEMPLATE 4.0 Recessed Low Voltage Cable Plate with Straight Blade Inlet ACTUAL SIZE CUT ALONG DOTTED LINE Page 4 of 4 9/21/12

Instruction / Installation Sheet DataComm Electronics 50-8823-WH-KIT Flat Panel TV Cable Organizer Kit with Duplex Surge Power Solution DataComm Electronics, Inc. 6349 Peachtree Street Norcross, GA 30071-1725 770.662.8205 Parts Included: 1. Recessed Low Voltage Mid-Size Plate with Duplex Surge Receptacle 2. Recessed Low Voltage Cable Plate with Straight Blade Inlet 3. Two (2) Electrical Outlet Boxes Four (4) Screws per Outlet Box 4. 15 Amp/125 Volt Duplex Surge Receptacle 5. Three (3) Wire Nuts 6. 6ft. 16/2 with Ground Cord Set with 360 o Rotating Head 7. 8 Electrical Wire - Romex Tools Needed: 1. Drywall Saw 2. 6 Ft. Tape Measure 3. Pencil 4. Screwdriver Use the Flat Panel TV Cable Organizer Kit with Duplex Surge Power Solution to install power and low voltage cables behind your flat panel TV, amplifier or other audio and video devices to your equipment room or at the location of your head end equipment (see Figures 1 & 2). Figure 1 Front View Figure 2 Back View IMPORTANT INSTRUCTIONS: Use the local electrical code approved installation when installing this product. The electrical parts in this kit are designed to be used only as a kit and none of these electrical parts are designed to be used individually. This product is not designed to be part of your home or a commercial building s electrical wiring system. This installation is only energized (electrically active) when the supplied 6 ft. cord is plugged into the recessed straight blade inlet located on the recessed low voltage cable plate and the straight blade end of the 6 ft. cord is plugged into either your surge protector or wall receptacle. If you are not familiar with home wiring systems, please call a qualified electrician to install this product. IMPORTANT INSTRUCTIONS: This product is designed for retrofit work only because the electrical outlet box cannot be attached to a stud. This product is designed to alert you if you ever lose surge protection. The Surge Suppressor Receptacle is designed to provide protection against shortterm over-voltage conditions as well as from RFI (radio frequency interference). The Surge Suppressor cannot survive, or provide protection in the rare event of a direct lightning strike on the service power line. The Surge Suppressor alerts you to the failure of the surge protection component by means of an audible signal. If alarm sounds, device has received power surges in excess of its capacity and is no longer functioning as a surge protector. To shut off alarm, simply turn the Alarm Off screw on the front of the receptacle clockwise. Note: When alarm sounds and the Alarm Off screw is turn off, the receptacle still functions as a normal duplex receptacle without surge protection. Installation Instructions for Retrofit Only: Select the location of your flat panel TV mounting bracket. Now select the location for both the wall plates for the Flat Panel TV Cable Organizer Kit with Duplex Surge Power Solution. Page 1 of 4 10/1/12

Installation / Instruction Sheet 50-8823-WH-KIT (Continued) Installation Instructions for the Top Plate with Duplex Surge Receptacle: Fig. 1 Figure 1 Top view - shows needed space between the drywall and the studs. Receptacle side of the Mid-Size Plate should be 3 from the stud but no more than 5 (review picture carefully). Fig. 2 Figure 2 Using the template supplied (see page 3 of instruction sheet), trace the opening needed. Using a drywall saw, cut a hole in the drywall the size of the template. See Figure 1 before tracing your opening. Remember, the plates are designed to be mounted between the studs. Fig. 3 Figure 3 Run the 14/2 w/ground UL approved electrical building wire (included in kit) from the top opening to the bottom opening and connect the Cable Plate with Duplex Surge Receptacle to the Cable Plate with Straight Blade Inlet. Make sure the piece of wire is long enough to allow for easy installation of the receptacles. Remember the Flat Panel TV Cable Organizer Kit with Duplex Surge Power Solution is not part of your home s electrical wiring system. Pull the electrical building wire through a hole in the top cable plate electrical outlet box. Use a screwdriver to open one of the knock outs on the electrical outlet box. Fig. 4 Figure 4 Now pull the other end of the electrical building wire through a hole in the bottom plate electrical outlet box. Use a screwdriver to open one of the knock outs on the electrical outlet box. Fig. 5 Figure 5 Using the supplied duplex surge receptacle, connect the hot line (black) wire to the brass colored terminal or screw and the neutral (white) wire to the silver colored terminal or screw. Be sure to connect the grounding (green) or bare grounding wire to the green colored terminal screw. For shock protection, this UR, UL recognized component receptacle must be properly grounded. Caution use copper wire only with this receptacle. Once you have wired the receptacle, screw the receptacle into the electrical outlet box until the receptacle is firmly secured. Fig. 6 Figure 6 Now use the four screws provided to secure the electrical outlet box to the mounting studs on the backside of the Mid-Size Plate with Duplex Surge Receptacle. Fig. 7 Figure 7 Stop: Important: Before installing the Recessed Mid-Size Plate with Duplex Surge Suppressor Receptacle into the template opening, make sure to pull your low voltage cables through the low voltage cable opening. If you have more than 4 cables you can remove the flexible plate that seals the low voltage cable opening. This allows for more cables to be pulled through the opening. After you have pulled your low voltage or A/V cables through the low voltage opening: Start with the bottom of the Recessed Mid-Size Plate with Duplex Surge Receptacle and slowly slide the plate into the opening. Swing the top of the plate into position until the entire plate is flush with the wall. Now screw down the screws with wings; these wings fasten tightly against the back of the drywall. Page 2 of 4 10/1/12

Installation / Instruction Sheet 50-8823-WH-KIT (Continued) Installation Instructions for the Bottom Cable Plate with Straight Blade Inlet Fig. 8 Figure 8 Wire the Cable Plate with Straight Blade Inlet to the supplied 14/2 w/ground UL approved electrical building wire. Connect the hot line (black) wire to the black wire and the neutral (white) wire to the white wire on the straight blade inlet. Be sure to connect the grounding (green) or bare grounding wire to the green wire on the straight blade inlet. Make sure the three wire nuts are fastened tightly. Fig. 9 Figure 9 Now use the four screws provided to secure the electrical outlet box to the mounting studs on the backside of the Cable Plate with Straight Blade Inlet. Fig. 10 Fig. 11 Figure 10 Important: Before installing the Plate with Straight Blade Inlet into the template opening, make sure to pull your low voltage cables through the low voltage cable opening. If you have more than 4 cables you can remove the flexible plate that seals the low voltage cable opening. This allows for more cables to be pulled through the opening. After you have pulled your low voltage or A/V cables through the low voltage opening: Start with the side of the Plate with Straight Blade Inlet and slowly slide the plate into the opening. Swing the right side of the plate into position until the entire plate is flush with the wall. Now screw down the screws with wings; these wings fasten tightly against the back of the drywall. Figure 11 Your new Flat Panel TV Cable Organizer Kit with Duplex Surge Power Solution is now installed and ready for the flat panel TV mount to be installed. Install your flat panel TV mounting bracket per the flat panel TV bracket manufacturer s instruction. Fig. 12 Figure 12 Hang your flat panel TV on the mounting bracket and plug your TV into the top Cable Plate with Duplex Receptacle. Now plug your cord set into bottom Cable Plate with Straight Blade Inlet. Then plug the male end of the cord set into a nearby wall receptacle. Duplex Surge Receptacle Specifications Inside the Hubbell Surge Protection Receptacles are two 22mm square MOV s providing 240 joules /15000A of surge protection for each mode. Meets UL Standards 1449 3rd Edition and 498: CSA Certified. Damage-alert alarm sounds when surge protection is no longer functioning and keeps sounding until the muting screw is utilized or the receptacle is replaced. Power-on indicator light verifies instantly that power is available at the receptacle and the suppression circuit is fully functional; light off means power has been interrupted, flashing light indicates surge protections circuitry has been damaged. Replacement surge suppressors can be purchased from DataComm Electronics or an authorized Hubbell Wiring Device distributor. 2-Pole 3-Wire Grounded 60 Hz Total Maximum Surge Dissipation Maximum Surge Current Surge Protection Clamping Response Time 15A-125V 480 Joules 15,000 Amps Hot/Neutral, Hot/Ground, Neutral/Ground 1 Nanosecond WARNING DataComm Electronics products shall be installed and used only as indicated in DataComm Electronics product instruction sheets. Instruction sheets are available online at www.datacommelectronics.com. CAUTION For shock protection, this device must be properly grounded. Use copper wire only with this device. IMPORTANT INSTRUCTIONS Read and understand all instructions. Follow all warnings and instructions marked on the product. Do not use this product near water, for example near a bath tub, wash bowl, kitchen sink, laundry tub, in a wet basement, or near a swimming pool. SAVE THESE INSTRUCTIONS. This product is patent protected by U.S. Patent numbers D553475, D554475 and 7390964. RoHS Compliant. Page 3 of 4 10/1/12

Installation / Instruction Sheet 50-8823-WH-KIT (Continued) ONLY LICENSED PROFESSIONALS SHOULD INSTALL THIS PRODUCT 6-1/2 TEMPLATE 4-1/2 Recessed Low Voltage Mid-Size Plate with Duplex Surge Receptacle ACTUAL SIZE CUT ALONG DOTTED LINE 4-11/16 TEMPLATE 4.0 Recessed Low Voltage Cable Plate with Straight Blade Inlet ACTUAL SIZE CUT ALONG DOTTED LINE Page 4 of 4 10/1/12