TECHNICAL DATA 2. LISTINGS AND APPROVALS. Spray Nozzle 11. December 20, 2013

esfr pendent sprinkler vk510 (k25.2)

ESFR DRY PENDENT SPRINKLER VK502 (K14.0) TECHNICAL DATA

Model KFR56 Series Quick Response Standard Spray

Sprinkler Identification Numbers

Model SW-20 and SW K-factor Extended Coverage Ordinary Hazard Horizontal Sidewall Sprinklers (Standard Response) General Description

Model F1FR Series Quick Response Glass Bulb Sprinklers

Series TY-FRB 2.8, 4.2, 5.6, and 8.0 K-Factor Upright, Pendent, and Recessed Pendent Sprinklers Quick Response, Standard Coverage General Description

Series TY-FRB 5.6 and 8.0 K-factor Extended Coverage Horizontal Sidewall Sprinklers Quick and Standard Response (Light Hazard) General Description

Sprinkler Identification Number. Page 1 of 6 MARCH 2014 TFP288. Worldwide Contacts.

Viking Residential Sprinkler Installation Guide

Model F156 Sprinkler Types. Model F156 Recessed Sprinkler Types. Model F142, F1XLH & F128 Sprinkler Types

Model/Sprinkler Identification Numbers

Model WS Specific Application Window Sprinklers Horizontal and Pendent Vertical Sidewall 5.6 K-factor General Description

Sprinkler Guards Model C Model D

Series TY-FRL 5.6 and 8.0 K-factor Extended Coverage Horizontal Sidewall Sprinklers Quick & Standard Response (Light Hazard) General Description

Series DS-1 Dry-Type Sprinklers 5.6K Horizontal Sidewall Standard and Quick Response, Extended Coverage General Description

Series ELO-231B 11.2 K-factor Upright and Pendent Sprinklers. Standard Response, Standard Coverage, General Description

Sprinkler Identification Numbers (SINs) Technical Data

Extended Coverage Sprinklers

Viking Residential Sprinkler Installation Guide

Model F822 thru F834 Mulsifyre Directional Spray Nozzles, Open, High Velocity General Description

Type EA-1 PROTECTOSPRAY Directional Spray Nozzles, Automatic, Medium Velocity General Description

Type D3 PROTECTOSPRAY Directional Spray Nozzles, Open, Medium Velocity General Description

HIGH VELOCITY WATER SPRAY NOZZLE

TECHNICAL DATA. 2. LISTINGS AND APPROVALS See Tables 1 & 2.

TECHNICAL DATA. Dry 122a. November 12, 2013

RESIDENTIAL SPRINKLER INSTALLATION GUIDE

IDENTIFICATION BROCHURE FOR Central RESIDENTIAL WET SPRINKLERS

IDENTIFICATION BROCHURE FOR Central COMMERCIAL WET SPRINKLERS

TECHNICAL DATA. 30a. September 18, /4-8 (DN32 - DN200)

Series MJC Multiple Jet Controls DN20, DN25, DN40, and DN50, 12 bar BSPT Inlet & Outlets Threads General Description.

PLAN SUBMITTAL REQUIREMENTS FOR SPRAY BOOTHS AND SPRAYING ROOMS EXTINGUISHING SYSTEMS

Clark County Fire Prevention

Replacement parts. WM97+ gas-fired water boiler Boiler Manual. OBTAIN PARTS ONLY THROUGH WEIL-McLAIN THE BOILER CONTAINS CERAMIC FIBER MATERIALS

NFPA 2001: Standard for Clean Agent Fire Extinguishing Systems NFPA 70: National Electrical Code (NEC) NFPA 72: National Fire Alarm Code

Tyco Fire & Building Products is a leading manufacturer and distributor of water-based fire suppression systems and components, offering one of the

08.08 Vic-Check Valves

RAPID RESPONSE Model RSV-1 Residential Shut-Off Valve, 1 Inch and 2 Inch (DN25 and DN50) for Dual-Purpose Residential Water Supply General Description

Your safety and the safety of others are very important.

CAST IRON THE BASICS. Heatline - Cast Iron Radiators SMOOTH FLAT FILE TO REMOVE ANY SWARF. ONE TIME. ASSEMBLY. JOINTS SHOULD BE TIGHTENED.

Rose Door Handles. We take the worry out of protecting what s valuable to you. Lockwood: no worries.

Features. Model EX Low Pressure Dry Pipe Valve System 2 (DN50), 2½ (DN65), 3 (DN80), 76 mm, 4 (DN100 ), 6 (DN150), 165 mm & 8 (DN200)

Terminal Boxes in Glass Fiber Reinforced Polyester (GRP)

EFSN Training i Module Minutes

Price Book - Section 20 Miscellaneous

TD01211 PIN: NX nd Edition. Water Motor Alarm MODEL: NX010 TECHNICAL DATA

Engineering Specifications

Select Radiators Installation Guide

Model 43AP Pneumatic Controller, Style B

SANTA ROSA FIRE DEPARTMENT FIRE PREVENTION BUREAU PLAN REVIEW CHECKLIST RESIDENTIAL FIRE SPRINKLERS NFPA 13D

Metal Pressfitting Pipe Systems

CLEAR-DIVISIONS CENTERFOLD

Reachout Lock Replacement for Andersen 2-Panel and 4-Panel 400 Series Frenchwood Gliding, 200 Series Narroline, and Perma-Shield Gliding Patio Doors

FACILITY FIRE-SUPPRESSION WATER-SERVICE PIPING

4077 AIRPARK DRIVE STANDISH, MICHIGAN PHONE FAX

C I T Y O F S E L M A F I R E D E P A R T M E N T

NEWSTAR BROCHURE. December 2007

TECHNICAL ASSISTANCE TOLL FREE TELEPHONE NUMBER TECHNICAL ASSISTANCE FAX:

Lift-off hinge. Rising hinge. Standard hinge. Heavy duty hinge. Parliament hinge. Spring hinge. Double action spring hinge. Concealed mortise hinge...

Stainless Steel Single and Dual Circulation Kits

CLEAR-DIVISIONS VARIOFOLD

Sliding and Folding Door Fittings Sliding Door Accessories

All work must conform to the National Electric Code, latest edition, and all other applicable codes and regulations.

Chapter 5 - Aircraft Welding

HVAC/R GAS TEST GAUGES SPECIFICATIONS ACCURACY CASE SIZES CASE MATERIAL MOUNTING STYLE HOUSING MATERIAL TUBE & SOCKET MOVEMENT RANGES DIAL STANDARD

K17.11 DOOR BOLTS K17 DOORS

4 Posiflow Proportional Solenoid Valves

Powers Controls Free Energy Band TH 193 HC Heating/Cooling Room Thermostat

Approved Products for Fire Protection Piping Systems

Automatic Fire Sprinkler Submittal Requirements

Commercial / HVAC / Plumbing. Specification Guide. For. Pressure & Temperature Instruments & Related Accessories

SANTA ROSA FIRE DEPARTMENT FIRE PREVENTION BUREAU PLAN REVIEW CHECKLIST RESIDENTIAL FIRE SPRINKLERS NFPA 13R

ball valves Flomite 71 Series 2-way Integral Panel Mount Ball Valves

What to Expect From the Examination. How to Study the Plumbing Codes

LINEAR MOTION CONTROL

FOAM CHAMBER MODEL - FC

Explosion-Proof Electric Unit Heaters

Powers Controls TH 192 HC Heating/Cooling Room Thermostat

Screw Plug Immersion Heaters

Mustang Series PRESSURE REDUCING CONTROL VALVE WITH PRESSURE SUSTAINING FEATURE. M115-2 (Globe) M (Angle) Schematic. Standard Components

Toroidal Conductivity Sensor

SECTION PIPE HANGERS AND SUPPORTS

Final inspections are completed by site visit only. Access to fenced yards shall be planned.

DiscPlus DX195 and DX225 Air Disc Brakes

We look forward to working with you. Worldwide Headquarters 1400 Pennbrook Parkway Lansdale, PA

How To Install An Evaporator Coil

3", 4", 6" & 8" Model H Series Alarm Check Valve Installation and Maintenance Guide

IMPORTANT DOCUMENTATION DO NOT DISCARD!

TECHNISCHE FICHE - TECHNISCHE FICHE - Chat Board: Classic

Installation Instructions and Ordering Information

9300BC SERIES Light Commercial Door Closer

2.8. Ex-Recess-mounted, ceiling emergency light fittings in compact metal design

Pipe threads for tubes and fittings where pressure-tight joints are not made on the threads. (requires PTFE sealing tape or liquid sealant).

33.6W Power over Ethernet Waterproof Adapter PoE Plus Single Port Injector for Outdoor Application

Steel Fire Sprinkler Pipe

Mini USB and USB 2.0-IP67 Connector System

Transcription:

January 1, 2011 Sprinkler 63a 1. DESCRIPTION Viking Quick Response Concealed Horizontal Sidewall Sprinkler VK408 is a small solder link and lever spray sprinkler designed for installation on concealed pipe systems. The sprinkler is hidden from view by a low profile, small diameter cover plate installed flush with the wall. Some installations may require the use of the optional conical adapter with the cover assembly to achieve a flush appearance. The cover plate and adapter are available in several decorative finishes to meet design requirements. The multi-piece design allows installation and testing of the sprinkler prior to installation of the cover plate. The push-on, pull-off design of the concealed cover plate assembly allows easy installation of the cover plate after the system has been tested and finish has been applied to the wall, while also permitting up to ½ (12.7 mm) of horizontal adjustment. The cover assembly and conical adapter can be removed and reinstalled, allowing access behind the wall without taking the sprinkler system out of service and removing the sprinkler. 2. LISTINGS AND APPROVALS culus Listed: Category VNIV NYC Approved: MEA 89-92-E, Volume 21 LPC Approved: Ref. No. 096e/11 CE Certified: Standard EN 12259-1, EC-certificate of conformity 0832-CPD-2030 Refer to the Approval Chart on page 63c and Design Criteria on page 63d for culus Listing requirements that must be followed. 3. technical data Specifications: Available since 2001. Minimum Operating Pressure: 7 psi (0.5 bar)* Rated to 175 psi (1 207 kpa) water working pressure. Spring: U.S.A. Patent No. 4,570,720 Thread size: 1/2 (15 mm) NPT Nominal K-Factor: 5.6 U.S. (80.6 metric ) *culus Listing and NFPA 13 installs require a minimum of 7 psi (0.5 bar). The minimum operating pressure for LPCB and CE Approvals ONLY is 5 psi (0.35 bar). Metric K-factor measurement shown is when pressure is measured in Bar. When pressure is measured in kpa, divide the metric K-factor shown by 10.0. Available Cover Plate Horizontal Adjustment: ½ (12.7 mm) +/- 1/4 (6.4 mm) Overall Length (Sprinkler Body): 2-11/32 (60 mm) Material Standards: Sprinkler Body: Brass UNS-C84400 Body Cap: Brass UNS-C26000 Deflector: Copper UNS-C19500 Deflector Pins: Stainless Steel UNS-S30300 Screw: Brass UNS-C36000 Belleville Spring Sealing Assembly: Nickel Alloy, coated on both sides with Teflon Tape Fusible Link Assembly: Nickel Alloy and Eutectic Solder Fusible Link Levers: Stainless Steel UNS-S31600 Lever Bar: Copper Alloy UNS-C72500 Lever Bar Ejector: Stainless Steel UNS-S30400 Cover Assembly Materials: Cover Plate Assembly: Brass UNS-C26000 or UNS-C26800 Spring: Nickel Alloy Solder: Eutectic Cover Adapter: 27 ga. (0.42 mm) thick 1010-1018 Mild Steel Viking Technical Data may be found on The Viking Corporation s Web site at http://www.vikinggroupinc.com. The Web site may include a more recent edition of this Technical Data Page. Form No. F_010301 Replaces page 63a-e, dated July 1, 2010. (Revised finish suffixes for white, black, and ivory painted cover finishes.)

Sprinkler 63b January 1, 2011 Ordering Information: (Also refer to the current Viking price list.) Viking Quick Response Concealed Horizontal Sidewall Sprinklers and Cover Plate Assemblies must be ordered separately: Sprinkler: Part No. 11262AC, 165 F (74 C) rated Cover Plate Assembly: Base Part No. 11451 Specify finish and temperature rating of the cover plate assembly by adding the appropriate suffixes for the finish and the cover temperature rating to the base part number: Finish Suffix: Polished Chrome = F, Brushed Chrome = F-/B, Bright Brass = B, Antique Brass = B-/A, Brushed Brass = B-/B, Brushed Copper = E-/B, Painted White = M-/W, Painted Ivory = M-/I, Painted Black = M-/B Temperature Suffix ( F/ C): 135 /57 = A, 165 /74 = C For example, cover 11451 with a Polished Chrome finish and a 165 F/74 C temperature rating = 11451FC. Available Finishes And Temperature Ratings: Refer to Table 1. Accessories: (Also refer to the Sprinkler Accessories section of the Viking data book.) Optional Conical Cover Adapter (see Figure 2): Base Part No. 11436, specify finish Sprinkler Wrenches*: A. Heavy Duty Wrench Part Number 08336W/B (available since 1983), or B. Head Cabinet Wrench Part Number 10366W/B** (available since 1998) *Requires a ½ ratchet (not available from Viking). **Ideal for sprinkler cabinets. Sprinkler Cabinet: Part No. 01731A (available since 1971) 4. Installation Refer to appropriate NFPA Installation Standards. 5. Operation During fire conditions, when the temperature around the sprinkler approaches its operating temperature, the cover plate detaches. Continued heating of the sprinkler causes the heat-sensitive fusible link to disengage, releasing the deflector and sealing assembly. Water flowing through the sprinkler orifice strikes the deflector, forming a uniform spray pattern to extinguish or control the fire. 6. inspections, tests and maintenance Refer to NFPA 25 for Inspection, Testing and Maintenance requirements. 7. availability Viking concealed sprinklers are available through a network of domestic and international distributors. See The Viking Corporation web site for the closest distributor or contact The Viking Corporation. 8. Guarantee For details of warranty, refer to Viking s current list price schedule or contact Viking directly. Sprinkler Temperature Classification TABLE 1: AVAILABLE SPRINKLER TEMPERATURE RATINGS AND FINISHES Sprinkler Nominal Temperature Rating 1 Maximum Ambient Ceiling Temperature 2 Ordinary 165 F (74 C) 100 F (38 C) Temperature Rating of Cover Assembly (Required) 135 F (57 C) 165 F (74 C) Cover Plate Base Part Number 3 Cover Plate Finishes: Polished Chrome, Brushed Chrome, Bright Brass, Antique Brass, Brushed Brass, Brushed Copper, Painted White, Painted Ivory, and Painted Black. Footnotes 1 The sprinkler temperature rating is stamped on the sprinkler body. 2 Based on NFPA-13. Other limits may apply, depending on fire loading, sprinkler location, and other requirements of the Authority Having Jurisdiction. Refer to specific installation standards. 3 Base part number is shown. For complete part number, refer to Viking s current price list schedule. 11451

January 1, 2011 Sprinkler 63c Sprinkler Base Part Number 1 SIN NPT Thread Size Approval Chart Quick Response Concealed Horizontal Sidewall Sprinkler Nominal K-Factor Maximum Water Working Pressure Overall Length (Sprinkler Body) Listings and Approvals 3,4 (Refer also to Design Criteria on page 63d.) Inch mm U.S. metric 2 Inches mm culus 5 NYC 6 LPCB 9 11262 VK408 1/2 15 5.6 80.6 175 psi (12 bar) 2-11/32 60 AX1, AY1 AX1, AY1 AX1, AY1 AX1, AY1 Sprinkler Temperature Ratings A - 165 F (74 C) Cover Plate Assembly Temp. Ratings 7 X - 135 F (57 C) Y - 165 F (74 C) Finishes of the Cover Plate Assembly 8 1 - Polished Chrome, Brushed Chrome, Bright Brass, Antique Brass, Brushed Brass, Brushed Copper, Painted White, Painted Ivory, or Painted Black Footnotes 1 Part number shown is the base part number. For complete part number, refer to current Viking price list schedule. 2 Metric K-factor measurement shown is when pressure is measured in Bar. When pressure is measured in kpa, divide the metric K-factor shown by 10.0. 3 This chart shows the listings and approvals available at the time of printing. Other approvals may be in process. Check with the manufacturer for any additional approvals. 4 Listed for use in Light or Ordinary Hazard Occupancies for use below smooth, flat, horizontal ceilings only. Position the deflector 4 to 12 (102 mm to 304 mm) below the ceiling and flush with the wall. 5 Listed by Underwriter s Laboratories for use in the U.S. and Canada. 6 Accepted for use, City of New York Department of Buildings, MEA Number 89-92-E, Vol. 27. 7 The 135 F cover has an orange label. The 165 F cover has a white label. 8 Painted finish consists of Polyester Baked Enamel. Other paint colors are available on request with the same listings as the standard paint colors. Listings and approvals apply for any paint manufacturer. Contact Viking for additional information. 9 Certified, Standard EN 12259-1, EC-certificate of conformity 0832-CPD-2030. NOTE: Custom colors are indicated on a label inside the cover assembly. Refer to Figure 3. Figure 1: Sprinkler Installation and Correct Use of Wrenches

Sprinkler 63d January 1, 2011 culus Listing Requirements: DESIGN CRITERIA (Also refer to the Approval Chart on page 63c.) Quick Response Concealed Horizontal Sidewall Sprinklers are culus Listed for installation in accordance with the latest edition of NFPA 13 for standard coverage sidewall spray sprinklers as indicated below: Designed for use in Light or Ordinary Hazard Occupancies for use below smooth, flat, horizontal ceilings only. Position deflector 4 to 12 (102 mm to 304 mm) below the ceiling. Align the top of the deflector parallel to the ceiling. The wrench ear on the top of the sprinkler is marked top. This sprinkler must be installed flush with the wall. The optional conical adapter may be installed between the cover plate and the surface of the wall, when a gap exists, to provide a flush appearance. Protection areas and maximum spacing shall be in accordance with the tables provided in NFPA 13 for standard s. Minimum spacing allowed is 6 ft. (1.8 m). Maximum distance from end walls shall be no more than one-half of the allowable distance between sprinklers. The distance shall be measured perpendicular to the wall. Minimum distance from end walls is 4 in. (102 mm). The sprinkler installation and obstruction rules contained in NFPA 13 for standard coverage sidewall spray sprinklers must be followed. NOTE: Concealed sprinklers must be installed in neutral or negative pressure plenums only. IMPORTANT: Always refer to Bulletin Form No. F_091699 - Care and Handling of Sprinklers. Also refer to page QR1-3 for general care, installation, and maintenance information. Viking sprinklers are to be installed in accordance with the latest edition of Viking technical data, the appropriate standards of NFPA, FM Global, LPCB, APSAD, VdS or other similar organizations, and also with the provisions of governmental codes, ordinances, and standards, whenever applicable. Figure 2: Sprinkler VK408 with Optional Conical Cover Adapter Figure 3: Identification of Custom Paint Color for Concealed Covers

January 1, 2011 Sprinkler 63e Figure 4: Sprinkler Dimensions and Cover Installation

THIS PAGE INTENTIONALLY LEFT BLANK Form No. F_010301 Replaces page 63a-e, dated July 1, 2010. (Revised finish suffixes for white, black, and ivory painted cover finishes.)