DES-200. User manual DES-200. Digital environmental parameters sensor. 1 io_des-200_en_v1.0. Copyright 2001-2011 CEL-MAR sp.j.



Similar documents
Electronic Control Devices The European Product Catalogue 2007

Duct Humidity Transmitter

WxGoos-1 Climate Monitor Installation Instructions Page 1. Connections. Setting an IP Address

PSDC PSDC 12V/8A/8x1A Power supply for up to 8 analog cameras PTC/TOPIC.

User s Manual Before using the inverter, you need to read and save the safety instructions.

Programmable set for Ethernet Modbus/TCP in IP67 TI-BL67-PG-EN-2

VOT-320. VOT-320V0xxL VOT-320V0xxH. Quick Installation Guide

PSACH v.1.0 PSACH 24VAC/6A/1x6A HERMETIC AC power supply for CCTV

NS-205-IP67 5-Port Industrial 10/100 Mbps Ethernet Switch with IP67 Casing

NV-EC1701. Ethernet over Coax Transceiver (+1) (+44) (0) Model NV-EC1701

=============================== WARNING

Mounting Plate / Screwdriver. Alignment Stickers Screws / Desiccant Bag / Double-sided Tape / Rubber Seal Plug / Rubber Washer

Ethernet Cat 5e & Cat 6 Patch Panels

TCP/IP MODULE CA-ETHR-A INSTALLATION MANUAL

Solar Home System. User Manual. AEH-SHS01-10W2L Solar Home System 2 Lamps

INPUT/OUTPUT MODULE CONVERT INPUTS AND OUTPUTS TO WIRELESS

ABB Drives. User s Manual HTL Encoder Interface FEN-31

User Manual Revision English

Analogue Input, 4-fold, MDRC AE/S 4.1, GH Q R0001

EPSOLAR LS0512R / LS0524R. Solar Light Controller INSTRUCTION MANUAL. Please read this manual carefully before using the product!

LS1024B / LS2024B/ LS3024B. Solar Charge Controller USER MANUAL

EMBEDDED ACCESS CONTROL Hardware Installation Guide

How To Control A Power Supply With A Mini Transmitter And Switch (Power Supply)

USB Rover port USB m Cat 5 Extender. User Guide

DMX2PWM 9 Channel Dimmer Setup Manual

User manual Rev 1.3 Contents

C-Bus Network Monitor

Signal Manager Installation and Operation Manual

User Guide. HDMI Active Cable Extender. DVI-7370c

An internal gyroscope minimizes the influence of dynamic linear acceleration on slope sensor readings.

FriendlyNet Hub 5-Port or 8-Port Ethernet Hub User s Manual

EE-SPY801/802. Photomicrosensors for detecting wafer-carrier mounting. Wafer-carrier Mounting Photomicrosensors. Ordering Information.

Meaco 30L and Meaco 40L dehumidifier instruction manual

EDI Distributor Control Interface Wiring and Setup Instructions

USER GUIDE. Studio Hotline Multi-line System Phone Flasher and Door/Alert Indicator Input Module and Indicator. DM Engineering. Version 1.

Operating Manual UMB Analogue/Digital Converter ANACON Order Number: 8160.UANA

Processor. Installation Guide

HT-150 Owner s Manual

Electronic Control Devices The European Product Catalogue 2007

USER MANUAL Stand Alone Power Supply PSQ 2909 / PSQ 3909 / PSQ 4909 PSQ 2920 / PSQ 3920 / PSQ 4920

PCS0100en Persy Control Services B.V. Netherlands

Recommended Tools and Supplies: Small Flat Blade Screwdriver, 35mm x 7.5mm DIN Rail. Qwik Install

Automation Unit TM 1703 ACP Flexible automation and telecontrol

Rosemount 333 HART Tri-Loop

ENET-710. ENET Ethernet Module ENET-710 JAN / 06 FOUNDATION

Zetron Desktop Microphone Manual F

Model: DC-A2IO Advanced HVAC Controller

Industrial Solar Power PoE Switch

connecdim Gateway G1 Ethernet TCP/IP to DALI

Temperature & Humidity SMS Alert Controller

CAUTION OPC-LM1-IL. Option Card for Encoder of Line Driver Output. Instruction Manual

PSU-U-24V/AC-6A/10/FTA-TR-MC PSAC 0624

MIC-BP4 Bi-Phase Converter Card For the MIC400 series camera

01. HARTING RJ INDUSTRIAL RJ45 ETHERNET CONNECTORS

Active Speaker System LX523 AUDAC PROFESSIONAL AUDIO EQUIPMENT. Active Speaker System with remote input LX523. User Manual & Installation Guide

PolyGard Carbon Monoxide CO Transmitter ADTX3 1110

5-port / 8-port 10/100BaseTX Industrial Ethernet Switch User Manual

MAKING MODERN LIVING POSSIBLE. AK-SC255 On-Site Installation Guide DANFOSS ELECTRONIC CONTROLS & SENSORS

UniPi technical documentation REV 1.1

Modular I/O System Analog and Digital Interface Modules

CAUTION OPC-LM1-ID. Option Card for Frequency Divider. Fuji Electric FA Components & Systems Co., Ltd. Instruction Manual

Features. Display. Measurements. Intelligent. Accuracy. Models. Installation DEIF A/S. Multi-instrument D

Manual. Solar Fountain Mobile Phone Charger

AIS750 Series Alarm Annunciator

Original instructions Tina 3A/Aps Adaptor unit

High Resolution Media Display - B series 20mm Pitch Outdoor RGB Module

Options for ABB drives, converters and inverters. User s manual FDPI-02 diagnostics and panel interface

DAM Series DAM124 4DIN+8AI+4DO Module Model No.:DAM124 WebSite:

alpha DSL WTM EG Instructions for use ADSL-Modem alpha DSL WTM EG

Installation Manual (English) Adjustable Active DP Terminator T1-Pepper Active RS485 segment termination for non-compliant cable

Temp. & humidity Transmitter Instructions

Sealed Industrial Ethernet Circular IP67 Cat. 5e RJ45 Connector System

KVM - DVI, USB 2.0, Cat 5 Extender

SHARKY 775 COMPACT ENERGY METER ULTRASONIC

KLQ750CO controller temp/intensity/feedback/24v/usb/rs622/analog trigger

SHARKY 775 COMPACT ENERGY METER ULTRASONIC

ABB Drives. User s Manual. Pulse Encoder Interface Module RTAC-01

CW46S GPS Sensor P R O D U C T B R I E F. Description. Features. Applications. Block Diagram

SWITCH! DESCRIPTION. ENVIRONMENTAL SPECIFICATIONS Operating Temperature: 0 C to +40 C SPECIFICATION SHEET:

CAT5 Video Display Quick Installation Guide

2-Pair HDSL1 Adtran Fiber Optic Link System

FCC COMPLIANCE STATEMENT

EZmoto V2. Product description Rev. 6 10/01/2014. EZmoto V2 Product description Rev.6 10/01/2014

DBS720 / FDS221-R / FDS221-W Sounder base, Alarm sounders

Index. ROPIX P18 Hardware ROPIX P18 Software ROPIX P18

alpha DSL WTM HS Instructions for use ADSL modem alpha DSL WTM HS

T0118 T2118 T3118. Instruction Manual

GREISINGER electronic GmbH

Solar Controller / Battery Charger User s Manual

WD-AMX Water Detection Controllers

NC-12 Modbus Application

ETC TWO STAGE ELECTRONIC TEMPERATURE CONTROL

Zlinx Wireless I/O. Peer-to-Peer and Modbus I/O B&B ELECTRONICS PRODUCT INFORMATION

iseries Ethernet cabling and configuration requirements

HARDWARE MANUAL. Ixx24-A 1/20. Val Controls A/S Limfjordsvej 3 DK-6715 Esbjerg N Tel vc@valcontrols.com

DAB+ / FM Tuner Model: TU-201

EBDSPIR-PRM, EBDSPIR-PRM-IP

MLC TM Maximum Productivity and Versatility for Control without Compromise!

WEB log. Device connection plans

Transcription:

User manual DES-200 Digital environmental parameters sensor Copyright 2001-2011 CEL-MAR sp.j. 1 io_des-200_en_v1.0

Contents 1. GENERAL ORMATION... 3 1.1. WARRANTED ORMATION... 3 1.2. GENERAL CONDITIONS OR SAE USE...3 1.3. ENVIRONMENTAL PRESERVATION...3 1.4. SERVICE AND CONSERVATION... 3 2. APPLICATION... 3 3. COOPERATION WITH OTHER 1-WIRE DEVICES...3 4. SENSOR VIEW... 4 5. SIGNALS LOCATION (OR RJ45 PLUG)...5 6. JP-1 JUMPER SETTGS... 5 7. STALLATION EXAMPLE... 6 8. VERSIONS... 7 9. SPECIICATIONS... 7 2

1. GENERAL ORMATION 1.1. WARRANTED ORMATION CEL-MAR Company gives a two-year warranty on the DES-200 sensor. The warranty does not cover damage caused from improper use, materials consumption or any unauthorized changes. If the product does not function in accordance with the instructions, will be repaired or replaced. All warranty and no warranty repairs must be returned with paid transport and insuring to the CEL-MAR Company. CEL-MAR Company under no circumstances won't be responsible for ensuing damage from improper using the product or as a result of random causes: the lightning discharge, the flood, the fire and the like. CEL-MAR Company is not be held responsible for damages and loss including: loss of profits, loss of data, pecuniary losses ensuing from using or the impossibility of using this product. In specific cases CEL-MAR Company discontinue all warranties and in particular do not follow the user manual and do not accept terms of warranty by the user. 1.2. GENERAL CONDITIONS OR SAE USE The device should install in the safe and stable place, the connecting cable should be arranged this way isn't exposed to treading, catching or tear out from sensor Do not put device on the wet surface. Do not connect devices for nondescript powering sources, Do not damage or crush powering wires. Do not make connection with wet hands. Do not adapt, open or make holes in casings of the device! Do not immerse device in water or no other liquid. Do not put the fire opened on device sources: candles, an oil lamps and the like. 1.3. ENVIRONMENTAL PRESERVATION This sign on the device inform about putting expended device with other waste materials. Device should send to the recycling. (In accordance with the act about the Electronic Appliance Expended from day 29 of July 2005) 1.4. SERVICE AND CONSERVATION It is recommended to check the status of cases and sensor connecting cables, to eliminate the effect of mechanical damage on the quality of measurement. Technical support at the number: +48 41 362-12-46 in 8.00-16.00, from Monday to riday 2. APPLICATION DES-200 Sensor is designed for multi-point measurement system of environmental parameters: rooms with structured cabling, automation cubicles, data communication cubicles, via the serial 1-WIRE us. Application of 1-Wire bus enables: the cooperation of many sensors connected to the same data lines, the deployment of sensors in various locations up to 260m, powering the sensors from the bus, guarantee the correct transmission of measurement data secure checksum CRC 3. COOPERATION WITH OTHER 1-WIRE DEVICES DES-200 sensor cooperates with 1-WIRE devices used for creation of monitoring and control systems for environmental parameters: ADA-401WP Thermosensor Module 1-WIRE to RS485-MODUS, DN-400 Passive 1-WIRE us Splitter, DN-215 Passive 1-WIRE us Splitter, DN-200 Passive 1-WIRE us Splitter, other 1-WIRE sensors eg. DTS-RJ45,, DTS-107, DES-200, DES-215, DES-300. 3

4. SENSOR VIEW 4

5. SIGNALS LOCATION (OR RJ45 PLUG) Signals location of modular plug: 8 1 1. -R return (cable RJ45/8WIRE white-orange) 2. -R return (cable RJ45/8WIRE - orange) 3. VDD power supply +5VDC (cable RJ45/8WIRE - white-green) 4. data line (cable RJ45/8WIRE - blue) 5. ground line (cable RJ45/8WIRE - white-blue) 6. NW not use (cable RJ45/8WIRE - green) 7. NW - not use (cable RJ45/8WIRE - white-brown) 8. NW - not use (cable RJ45/8WIRE - brown) 6. JP-1 JUMPER SETTGS Setting of JP-1 Connection type Topology S CH JP-1 Star connection sensor S CH JP-1 Chain connection sensor 5

7. STALLATION EXAMPLE 6 DES-200 Computer with reescada software or PLC with supporting of MODUS protocol RS232 US RS485 MODUS E E 1-WIRE RS485 MODUS ADA-401WP ADA-I1040 ADAI9140 -R -R

8. VERSIONS DES-200 - - Sensor type: Temperature () PREPARG - Relative humidity ( 0%... 100%) PREPARG - Temperature and relative humidity ( 0%... 100%) PREPARG - Atmospheric pressure ( 150hPa... 1150hPa) PREPARG - Temperature and atmospheric pressure ( 150hPa... 1150hPa) PREPARG - Sunlight ( 0%... 100%) PREPARG - Ambient light ( 0%... 100%) Casing: T H TH AP TAP SL L Order example: Product symbol: DES-200-T-1 T - Temperature sensor 1 - Casing for mounting with screws or mounting with screws 1 or sticking 2 9. SPECIICATIONS Parameters Data Temperature Sensor Measuring range Transducer DS1820 Measuring range of transducer -55 C 125 C Measuring accuracy of transducer +/-0,5 C in scope -10 C...+85 C Resolution transducer 12 bits (0,06 C) Operating range ( PREPARATION) Humidity Sensor Measuring range of relative humidity 0%... 100% RH Measuring accuracy of relative humidity +/-3,50% RH Operating temperature range ( PREPARATION) Atmospheric Pressure Sensor Measuring range of atmospheric pressure 150 hpa... 1150 hpa Measuring accuracy of atmospheric pressure +/-15 hpa Operating temperature range (I PREPARATION ) Sunlight Sensor Measuring range of sunlight --- Measuring accuracy of sunlight --- Operating temperature range ( PREPARATION) Ambient light Sensor Measuring range of ambient light --- Measuring accuracy of ambient light --- Operating temperature range General Parameters Supply voltage from 1-WIRE us, VDD=5VDC 7

Max. power Parameters Protection from reverse power polarization us cabling Operating temperature Material Protection degree Dimensions Weight Storage temperature Humidity Data 10mW YES Warning! for reverse powering, is shorted VDD to recommended UTP 4x2x0.5 AWG24 twisted cable Casing Storing and Transportation from -30 C to +70 C polystyrene IP20 50,2 x 40,2 x 20,6 mm 0,02 kg -30 C +70 C 5 95% - non-condensing Dear Customer, Thank you for purchasing CEL-MAR Company products. We hope that this user manual helped you to connect and start up the purchased device. We also wish to inform you that we are a manufacturer of: data transmission converters with interface RS232, RS485, RS422, US, Current Loop, iber Optic Converters, 1-Wire, ETHERNET, Wi-i; digital sensors as: temperature, humidity, pressure, illumination; power supply Please express your opinion by e-mail or phone on this product, and advise us how we can satisfy you present and future of expecting. CEL-MAR sp.j. Computers Science and Electronic actory str. Ściegiennego 219C 25-116 Kielce, Poland Tel/fax... : +48 41 362-12-46 ax... : +48 41 361-07-70 Web... : http://www.cel-mar.pl Office... : office@cel-mar.pl Sales department... : sales@cel-mar.pl Technical information... : suppert@cel-mar.pl 8