RayClic Connection System Installation Instructions



Similar documents
RayClic Connection System Installation Instructions

TraceTek TTDM Series Leak Detection and Location Modules Replacement Parts Installation Instructions

Thermwire. Selection Guide. Freeze Protection Heating Cable. Thermwire -Wrap. Pre-Assembled. Thermwire-Comp. Thermwire-Melt.

GENUINE PARTS INSTALLATION INSTRUCTIONS

NELSON HEAT TRACING SYSTEMS

COLD LEAD OPTIONS FOR XMI MINERAL INSULATED (MI) HEATING CABLES

Cable Cubby 1200 and 1400 Installation Guide

BILLET HEADLAMP WITH SHORT/TALL MOUNTS

KSR-SK-DB In-Line Splice Kit KSR Snow Melting Cable INSTALLATION PROCEDURES

5800 Temperature Sensor Cable Assembly

BUILT-IN DISHWASHER INSTALLATION INSTRUCTIONS

RMM2 Heat-Tracing Remote Monitoring Module for the Raychem NGC Control System Installation Instructions

Andersen Electric Window Opener for Andersen Awning and Roof Windows

Heat Tracing Sales Mt. Airy, Maryland Installation Instructions

Frost Heave Protection System Installation and Operation Manual for Self-Regulating Heating Cable Systems

Installation Instructions S

Step 1. Item 6. Item 1

SCTK INSTALLATION PROCEDURES. Splice Connection Termination Kit. SCTK-1D for BSX, RSX, VSX SCTK-2D for KSX, HTSX SCTK-3D for HPT, FP

Contact Information: Electrical Connection Kit for CL Series Constant Wattage Temptrace for Low Temperature Maintenance.

AMERBRITE UNDERWATER WHITE LED POOL LAMP

Products and services

PowerFlex 700S and 700H Frame 12 DC Bus Connector Kit

LED MOTION ACTIVATED FLOOD LIGHT

Installation Instructions

TABLE OF CONTENTS. I. TROUBLESHOOTING Section 1.01: Common Problems/Solutions... 2

Installation Instructions DTS-HAZ DTS-HAZ-DC. for Use with Self-Regulating & Constant Wattage Heating Cables

UPGRADING AND SERVICING GUIDE

Elo Touch Solutions Wall-mounting Kit for the 5501L IDS Touchmonitors

TOYOTA Tundra BACK-UP CAMERA SYSTEM Preparation

apple Service Source PowerBook G4 (DVI) Updated 4 December Apple Computer, Inc. All rights reserved.

1. SAFETY RULES. 8. Avoid placing objects in the path of the blades.

READ THIS MANUAL BEFORE PROCEEDING WITH THE INSTALLATION. FAILURE TO FOLLOW THE INSTALLATION INSTRUCTIONS MAY VOID YOUR WARRANTY!

FAK-7HTS High Temperature Tubing Bundle End Seal Kit INSTALLATION PROCEDURES

ScreenLogic Wireless Connection Kit. Installation Guide. pool/spa control system

Cooktop Low-Profile Ventilation Hoods

Service Guide. Gateway M275

Replacing the Gateway M675 Keyboard

INSTALLATION INSTRUCTIONS

with installation dynafact boost GAUGE this manual is for use with systems

I NTERFACE CABLE ADAPTER MODULE

Owners & Installation Manual for the Sheridan, Mountainair, Pine Valley and Old Forge Ceiling Fan Family

CUSTOM AUXILIARY FORWARD LIGHTING KIT

Navico-Northstar 2kW JRC Radar Package, Scanner Cable Removal and Replacement

GPS AutoSteer System Installation Manual

Post Mount Light Installation*

SYSTEM 1850-SE SERVICE ENTRANCE CABLE SYSTEM

Installation Instructions

EZ-Steer Assisted Steering System

Cabinets 101: Configuring A Network Or Server Cabinet

Direction of current flow through conductor. Fig. 1 Magnetic field generated by current flow

Table of Contents. What to Expect with. Preparation. Tools Needed. Wiring. Hanging the Fan. Blades. Motor Housing.

Industrial Control Solutions

Sense Components. Sense monitor. Antenna assembly. External mounting kit Current sensors. Download the Sense app. Go to sense.com/app.

1. SAFETY RULES WARNING TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK OR PERSONAL INJURY, MOUNT FAN TO OUTLET BOX MARKED "ACCEPTABLE FOR FAN SUPPORT".

CoolWave r 2 Phase Control Board and Cable Replacement Kits

FL ADJUSTABLE RIDER BACKREST MOUNTING HARDWARE KIT

Installation Instructions

Installation. Smart-UPS VT and MGE Galaxy Maintenance Bypass Panel with Power Distribution (wall-mount) kva 208 V

Installation Instructions For Slider Casement Air Conditioners

FRONT BUMPER INSTALLATION INSTRUCTIONS DODGE / MERCEDES SPRINTER

INSTALLATION INSTRUCTIONS

Electric Heat Tracing INSTALLATION PROCEDURES

Arecont Vision H.264 Color or Day/Night SurroundVideo Series Installation Manual

Installer s Guide WARNING: 18-GJ11D1-2. Ultraviolet (UV-C) Lamp Kit for 2-5 Ton Air Handlers HAZARDOUS VOLTAGE - DISCONNECT POWER BEFORE SERVICING

DETACHABLE WINDSHIELD AND DOCKING HARDWARE KIT

758 Heavy-duty Ratchet Guy Wire Cutter

Rain+Birdt. Simple To Set Timer (SST) Setup & Operation Instructions. English RAIN BIRD ( ) or visit

Quartzone Infrared Quartz Tube & Metal Sheathed Electric Heaters

Intel RAID Maintenance Free Backup Unit 4 Quick Installation User's Guide

INFRARED QUARTZ WALL HEATER

SHOT BLAST CABINET MODEL NO: CSB20B

ELECTRONIC THERMOSTAT AND THERMOMETER With SPEED CONTROL

4.3-inch Back-Up Camera

Installation Instructions

XL-Trace System Installation and Operation Manual

Subject: Circuit Board troubleshooting Bulletin

AM/FM ANTENNA KIT (TOUR-PAK MOUNT)

QT Residential Blower Metal Residential Blower

V Installation instructions, accessories. Digital radio DAB. Volvo Car Corporation Gothenburg, Sweden. V70 (08-) 2011 Volvo Cars Europe

SCREENLOGIC INTERFACE WIRELESS CONNECTION KIT

Installation Instructions SELF-REGULATING (SR) ROOF AND GUTTER DE-ICING CABLES INDUSTRIAL AND COMMERCIAL SERIES

AM/FM ANTENNA RELOCATION KIT

Depending on which elastic support you have you can secure the V2 power unit to the following seat bracket tubes: EXTERNAL DIAMETER 27.

Express5800/120Ed. Rack Mount Kit Installation Procedures PN:

DTS-HAZ DTS-HAZ-DC. Installation Instructions. for use with Self-Regulating, Constant Wattage & Mineral Insulated Electric Heating Cables

3. SEISCO PARTS & SERVICE REMOVAL AND REPAIR GUIDE

P150SC15. Designed for 2015 Ford F150 Super-Cab and Super-Crew vehicles without Sony System Stillwater Designs P150SC15-A

SERVICE MANUAL RESIDENTIAL ELECTRIC AND LIGHT DUTY COMMERCIAL ELECTRIC WATER HEATERS. Troubleshooting Guide and Instructions for Service

Roof Top Air Conditioner INSTALLATION AND OPERATING INSTRUCTIONS

Detector transparent with Color Inserts. FAA 500 TR P Trim Ring transparent with Color Inserts. FCA 500 / FCA 500 E Detector Bases

EZ-Steer Assisted Steering System

COYOTE PUP CLOSURE FOR UNDERGROUND, AERIAL, AND BURIED SPLICES 6.0" x 17" (152.4 mm x mm)

INSTALLATION INSTRUCTION SPEC. SHEET 7/00. City of New York Calendar #40747 ETL LISTED UNDER U.L. STD LOW VOLTAGE TRACK LIGHTING SYSTEM

For exploded diagram and part number information, refer to the Spare Parts Catalog available on our website at

HP UPS R1500 Generation 3

OWNER S MANUAL Table Tennis Table Patent Pending

Traditional Sonar and DSI Sonar Installation

ATS Overhead Table Shelf System INSTRUCTION MANUAL

Packard Bell Easy Repair

Transcription:

RayClic Connection System Installation Instructions Description RayClic-S Splice Kit RayClic-T Tee and End Seal Kit RayClic-X Cross and End Seal Kit These kits are for use with Raychem IceStop, XL-Trace and HWAT heating cables. The connection is designed to be strapped to the pipe, or wall mounted. These installation instructions should be used in conjunction with the IceStop, XL-Trace, and HWAT System Installation and Operation Manuals. For technical support, contact your Pentair Thermal Management representative or call Pentair Thermal Management (800) 545-6258. Tools Required TORX T20 screw driver Utility knife Wire cutters Approvals APPROVED 718K Pipe Heating Cable 877Z De-Icing and Snow Melting Not UL Listed with XL-Trace heating cable -w for buried piping. For HWAT, IceStop, and XL-Trace only Hazardous Locations: For IceStop (GM-XT) only Class I, Div. 2, Groups A,B,C,D Optional Accessories (not included in this kit) RayClic-SB-02 Wall mounting bracket RayClic-SB-04 Pipe mounting bracket WARNING: This component is an electrical device that must be installed correctly to ensure proper operation and to prevent shock or fire. Read these important warnings and carefully follow all the installation instructions. To minimize the danger of fire from sustained electrical arcing if the heating cable is damaged or improperly installed, and to comply with the requirements of Pentair Thermal Management, agency certifications, and national electrical codes, groundfault equipment protection must be used. Arcing may not be stopped by conventional circuit breakers. Bus wires will short if they contact each other. Keep bus wires separated. Keep components and heating cable ends dry before and during installation. The black heating cable core is conductive and can short. It must be properly insulated and kept dry. Component approvals and performance are based on the use of Pentair Thermal Management-specified parts only. Do not use substitute parts or vinyl electrical tape. Leave these instructions with end user for reference and future use. 1 / 10

Kit Contents RayClic-S Splice Kit Item Qty Description A 1 Splice B 2 Plastic cable ties C 2 Clips D 3 Labels (1 splice, 2 warning) E 1 Cable lubricant A B C D E RayClic-T Tee Kit Item Qty Description A 1 Tee B 2 Plastic cable ties C 3 Clips D 1 End seal E 3 Labels (1 splice, 2 warning) F 1 Cable lubricant A B C D E F Rayclic-X Cross Kit Item Qty Description A 1 Cross B 2 Plastic cable ties C 4 Clips D 2 End seals E 3 Labels (1 splice, 2 warning) F 1 Cable lubricant A B C D E F 2 / 10

If you experience difficulty during installation, refer to the Troubleshooting Guide on page 8. For pipe-mounted applications follow steps 1 through 10 (pages 3 5). For roof-mounted applications, follow steps 2 through 9 (pages 3 5), then turn to Roof Installation on page 6. Splice, Tee, and Cross Installation 1 2 Place kit on pipe and attach with plastic cable ties. Allow enough extra heating cable to make service loops as required. Make sure the end of the heating cable is cut clean. 3 4 Do not cut through metal braid or inner jacket. Score around and down the outer jacket of the heating cable 3 1/8-inches from the end. Remove the outer jacket. Place the metal clip over the base of the exposed braid. 3 / 10

HWAT 5A HWAT Only IceStop and XL-Trace 5B IceStop and XL-Trace Only Using wire cutters, cut away 1-inch of the braid. Pull exposed braid back over metal clip. Pull exposed braid back over metal clip. Using wire cutters, cut away aluminum wrap. 6 7 Apply a small amount of lubricant to the jacket surface near the end of the cable. Avoid using large amounts of lubricant on the exposed end of the cable. Insert prepared heating cable end into connector. Push until heating cable is fully inserted and end is visible through opening in connection cover plate. Note: Heating cable cannot be removed. The connection and end seal are designed to be installed only once; the heating cable cannot be removed once installed. 4 / 10

R 8 Tighten the screws until the metal top surface is at the same height as the inner clear plastic module. 9 Securely tighten the two connection screws, alternating as they are being tightened. WARNING: Fire hazard. Loose screws can cause excessive heating. Be sure screws are fully tightened. Repeat steps 2 through 7 for all remaining heating cable entries. 10 11A Splice Close the lid and snap the lever shut. Do not force lid closed. If lid does not close, check the connection to ensure all screws are fully tightened. Tighten the nuts on the heating cable entries until grommets are compressed. Using glass cloth tape, attach heating cable to pipe. Apply insulation, cladding, warning labels and yellow splice identification label. 11B TEE (insulation not shown) 11C CROSS (insulation not shown) Using glass cloth tape, attach heating cable to pipe. Apply insulation, cladding, warning labels and yellow splice identification label. Using glass cloth tape, attach heating cable to pipe. Apply insulation, cladding, warning labels and yellow splice identification label. 5 / 10

Roof Installation 1 2 RayClic-SB-02 Mount flat (wall-mounting) bracket by installing screws through the center holes. Mount bracket above water line. Do not mount in gutter or where it may be immersed in water. RayClic-S RayClic-T and RayClic-X Position attachment clips on mounting bracket based on the type of connector being installed. 3 4A Splice Drip loops Prepare and attach heating cables as detailed in steps 2 through 9 (pages 3 5). Attach connector to mounting bracket by pressing until it snaps into place. Complete heating cable installation and install drip loops as shown. Protect heating cable from sharp edges. 4B Tee Drip loops Attach connector to mounting bracket by pressing until it snaps into place. Complete heating cable installation and install drip loops as shown. Protect heating cable from sharp edges. 6 / 10

End Seal Installation 1 2 Remove exposed braid. 1" Score down and around outer jacket 1 inch from the end. Remove the outer jacket. Do not cut or damage inner jacket. HWAT IceStop, XL-Trace, and RaySol 2A Using wire cutters, cut away aluminum wrap close to braid and outer jacket. 3 Push end seal completely onto heating cable. Note: The end seal can be installed only once; it cannot be removed from the heating cable. Do not use until ready for final installation. 7 / 10

Troubleshooting Guide Problem Braid clips are missing. Mounting bracket is missing. Connector does not snap onto bracket. Heating cable type not mentioned. Braid clip does not fit. Heating cable does not have aluminum wrap. Heating cable cannot be inserted into connector. Lid does not close. Heating cable cannot be inserted into end seal. Heating cable cannot be removed. Solution The braid clips are attached to the cardboard packing insert under the lid. The braid clips must be used to ensure a ground connection. If clips are missing or lost, call Pentair Thermal Management at (800) 545-6258. A mounting bracket is not included in the splice, tee and cross kits. One can be ordered using one of the catalog numbers listed under Optional Accessories on the front page of these instructions when you place your order. The bracket has two sets of attachment clips. Fold up the four outer clips for the splice kit. Fold up only the center clips for the tee and cross kits. RayClic connection kits are approved for use only with Raychem HWAT, XL-Trace, and IceStop heating cables. Do not use with other heating cables. Be sure the clip is installed on the metal braid, not on the outer jacket. Only HWAT heating cables have the aluminum wrap under the braid. Skip the aluminum wrap removal step for XL-Trace and IceStop heating cables. Check for the following: Apply cable lubricant to the heating cable primary (white) jacket. Outer jacket strip length is 3 1/8-inches. Braid clip is installed on top of the metal braid, not on the outer jacket. Braid is pulled back over braid clip. For HWAT, 1-inch of braid is removed. Sealing nut is loose (but not removed). Connection screws are loose. Be sure all screws are fully tightened before closing the lid. The outer jacket must be removed from the heating cable before the end seal is installed (see the End Seal Installation instructions on page 7). Make sure 1-inch of the outer jacket, braid, and aluminum wrap (HWAT only) are removed. The connection and end seal are designed to be installed only once; the heating cable cannot be removed once installed. Additional RayClic-E end seals can be ordered from Pentair Thermal Management. 8 / 10

Heating Cable Circuit Testing The RayClic-T now includes test ports in the blank module. Voltage can measured at these points to confirm continuity or power to the installed heating cable circuit. For detail heating cable operation refer to the appropriate installation and operating manual. Instructions: 1. Open the RayClic Cover. 2. Set multimeter to AC voltage function. 3. Insert multimeter test probes into the two test ports. WARNING: To avoid shock do not cross the test probes or touch them to the metal pressure plate when measuring voltage. Test ports 9 / 10

WWW.THERMAL.PENTAIR.COM NORTH AMERICA Tel: +1.800.545.6258 Fax: +1.800.527.5703 Tel: +1.650.216.1526 Fax: +1.650.474.7711 thermal.info@pentair.com Europe, Middle East, Africa Tel: +32.16.213.511 Fax: +32.16.213.603 thermal.info@pentair.com Asia Pacific Tel: +86.21.2412.1688 Fax: +86.21.5426.2917 cn.thermal.info@pentair.com Latin America Tel: +55.11.2588.1400 Fax: +55.11.2588.1410 thermal.info@pentair.com Pentair, HWAT, IceStop, RayClic, and XL-Trace are owned by Pentair or its global affiliates. All other trademarks are the property of their respective owners. Pentair reserves the right to change specifications without prior notice. 1995-2013 Pentair. PN 473303-000 10 / 10