INTERNATIONAL FIRE PROTECTION



Similar documents
Fire-Rated Glass and Glazing START

FIRE-RESISTANT GLAZING Mr Leslie O May Sales Consultant Wright Style Limited England

PYROSWISS VETROFLAM CONTRAFLAM

Fire-resistant barriers: background on requirements and determination method. Reading guide for test reports.

Building Code Clarifications - 7. Fire Resistance

GENERAL FIRE SAFETY TERMS & DEFINITIONS

Code of Practice for fire resisting metal doorsets

EFA PSBP. Natural Ventilation Strategy. Introduction. 1.1 Relevant legislation The Building Regulations 2010

Requirements for Fire Protection of Light Weight Floor Systems **Act 1 Revisited**

LPCB Red Book Listed Products and Passive Fire Protection Installer Schemes Answering the needs of the market

Additional Guidance. for application to. HM Government Guide to Fire Safety Risk Assessment Residential Care Premises

CI/SfB Ro8 (K3) February Fire-Resistant Glass Range. Pilkington Pyrostop Pilkington Pyrodur Pilkington Pyroshield

ALVERNIA UNIVERSITY OSHA REGULATION: 29 CFR WELDING, CUTTING, AND BRAZING ( HOT WORK ) SECTION: 3600

From Wired Glass to Clear Solutions: Designing with Fire Rated Glass Today

BUILDING CONTROL GUIDANCE SHEET REPLACEMENT WINDOWS AND DOORS Last updated 16/11/2010

New Ontario Building Code Requirements for Mid-rise Wood Frame Buildings

Fire 2This Technical Bulletin has been commissioned by the UK SIP Association in

Fire Testing of Recycled Materials for Building Applications

In accordance with NFPA 30, these containers are not to store Class I flammable liquids.

Decree of the Ministry of the Environment on fire safety of ventilation systems

Fire Protection Of Ventilation Systems DAMPERS & AIR TRANSFER GRILLES A PRESENTATION BY PHILLIP HORTON OF FIRE ENGINEERING SOLUTIONS

Fire Development and Fire Behavior Indicators

Opening the Bonnet. Prof Darren Woolf WYSINWYG 1

IGNITION-RESISTANT CONSTRUCTION: THE WHY BEHIND THE WHAT

Composite Panel Firewall Systems

Safety Storage Cabinets

Risk Asse ssment as a Tool to Protect Historical Buildings

Guidance on loft conversions in two-storey houses

Fire Resistant Systems

FIRE RATED GLAZING System Guide

Fire Safety in High Rise Residential Blocks

FIRE LOSS STATISTICAL CONSIDERATIONS IN RELATING FAILURE AND BUILDING DAMAGE TO THE BUILDING CODE OBJECTIVES

Rainwater Harvesting

FIRESTOPPING & SMOKE SEALS

PYRAN PYRANOVA. Special-purpose glass products for fire resistant glazing

HOT WORK PERMIT PROGRAM TRAINING. John Braun

How To Write A Fire Risk Assessment

PROFESSIONAL SYSTEMS DIVISION - COMPLETE COMMERCIAL SOLUTIONS

Fire Safety Risk Assessment Checklist for Residential Care Premises

ON MOST schemes, the architectural design of. Flexible strategy. Case study. The Forum

Residential Windows, 3 rd edition Corrected index 1

Safe Operating Procedure

A study of the nature of fire risks in tall buildings

Denver Fire Department Idle Pallet Storage Guidelines Per NFPA 13_Chpt 12

General Safety & Health Standards Published by the Division of Building Safety In Cooperation with the Idaho Industrial Commission

FIRE AND SMOKE PROTECTION FEATURES

THERMAL BARRIERS FOR THE SPRAY POLYURETHANE FOAM INDUSTRY

The BASA Guide to the ISO Classification of Sealants for Building Construction

Fire Doors Explained. Presented by - Peter Barker

Energy Efficient Windows

St. John s University

- 5 - Table1. Maximum Compartment Volumes

The Role of Fire Doors. BWF-Certifire Fire Door and Doorset Scheme

Module 2.2. Heat transfer mechanisms

FIRE DETECTION AND ALARM SYSTEMS

PYROVITRO FIRE-RESISTANT GLASS

CERTIFICATE OF APPROVAL No CF 291 SCHOTT UK LIMITED

St. Werburgh s. Fire,Smoke & Water Damage. Threats to Faith,Fabric &Future. Joseph A Gannon. FRIAI, MUBC(UCD).I.Eng.MIFire E

Understanding fire-resistant glazing systems. Presented by Russell Day Technical officer The Glass and Glazing Federation

Fire Safety Requirements for Child Care Centre

to encourage high quality tropical vernacular Queensland architecture throughout the Shire;

FIRE RISK ASSESSMENT

2010 edition. Handbook of. Fire-Rated Glass. for schools

Underwriters Laboratories Testing Information

the value of electrical inspection 70 IAEI NEWS July.August November.December

Civil Engineering and Architecture (CEA) Detailed Outline

Terms and Definitions In Canada

FIRE-RESISTANCE-RATED CONSTRUCTION

ENVIRONMENTAL HEALTH PROFESSIONAL PRACTICE VOL II CHAPTER III. HOUSES IN MULTIPLE OCCUPATION Space Standards

M E M O R A N D U M. To: Partnership for Safer Buildings Date: 21 March 2003

FIRE-RESISTANCE-RATED CONSTRUCTION

Certification: Building Plans Examiner. Exam ID: B3

HealthandSafetyOntario.ca. Introduction. Storage Containers. Storing Flammable Liquids

windows doors conservatories

HOOVER TREATED WOOD PRODUCTS, INC. TECHNICAL NOTE FOR ADDITIONAL INFORMATION: TEC-WOOD ( )

A Guide to Best Practice in the Specification and Use of Fire-Resistant Glazed Systems

Solar Homes Catch the Sun. Are you planning a new house? Discover how you can apply solar architecture principles to:

Overview of Hotel Fire Safety Requirements

Tremco Fire Protection Systems Group Technical Bulletin

IFE Level 4 Certificate in Fire Science and Fire Safety (HL)

Executive Summary Inclusion of Current Firewall Requirements in NBCC

NFPA 101 SAF-FIR PUBLIC COMMENTS

eading Performance Solutions

Access onto roof from Center Block

Innovation Beyond Double Glazing

Pyroguard Wired Glass

Building Codes Update: The 2009 International Fire Code and the Apartment Industry

Know the Code: Using Spray Foam Insulation In Attics and Crawl Spaces

Fire testing for BCA compliance

Windows are one of the most important components of a

REVEWED BY: Ross Rogien B.O/P.R. ADDITIONAL REVIEW(S) REQ.-FIRE DEPT Y/N

FLA S FIRE SAFETY INITIATIVE

Recommendations to improve the safety of existing lifts

foot skylight) is enough to knock a worker off their feet. A 10 mph wind gust on a 5 x 6 skylight develops a wind force of 270 lbs.

Building Control Guidance Note

Services Enclosures and Protected Shafts - Maintaining Compartmentation

Ch. 58 DIVISION D-O 34 CHAPTER 58. DIVISION D-O ORDINARY COMMERCIAL, INDUSTRIAL, OFFICE OCCUPANCY GROUP CONSTRUCTION TYPE MAXIMUM STORY HEIGHT

Introduction. CE marked construction products

Acoustic Design Practices for Sustainable Buildings

Property Accreditation Standards 2014/2015

Transcription:

An MDM PUBLICATION Issue 39 August 2009 www.mdmpublishing.com INTERNATIONAL FIRE PROTECTION THE GLOBAL VOICE FOR PASSIVE & ACTIVE FIRE PROTECTION

Progress with fire-resistant glass Limiting risk, reducing uncertainty By Mike Wood Pilkington Group Ltd Glass is such a common and familiar material in today s architecture that there is a risk that too much is taken for granted concerning its behaviour in fire. Glass architecture and design practice continue to advance by leaps and bounds; each new iconic building that goes up seems to lead with another structural innovation. Fire-resistant glass, and the understanding of glass in fire, have also advanced in parallel, influenced by the trend to open building design in the shadow of the threat from fire to an increasingly complex congested built environment. It is important that those advances are given full recognition. Myth and mystique Some assumptions are simply not justified given the fundamental nature of glass. For example, higher impact strength (e.g. as toughened glass) is sometimes implicitly taken generically to mean strength in fire. Not so the two are different and governed by entirely different factors. Equally, standard annealed glass and double glazed units are too often erroneously assumed to provide an acceptable degree of resilience. Single glazing easily cracks in fire and a double glazed unit shows consistent integrity failure in tests after only a few minutes exposure. A too literal interpretation of the terms safety and security applied to glass products may also lead to misconceptions. Products in this category, for example laminates based on plastic organic interlayers, fail catastrophically in fire after glass cracking followed by smoking, with dripping of the hot liquid interlayer and flaming. Glass is not a material with inherent resilience against fire. To have any practical and significant fire resistance, especially against various fire scenarios, requires a special and robust fireresistant technology. Regulations Countries the world over recognise the importance of making provision for fire safety in their country regulations governing buildings, design, and construction. Some may have well established regulations over more than fifty years, others may INTERNATIONAL FIRE PROTECTION 37

only just be developing up-to-date guidance. In all cases, the applicable regulations are influenced by local tradition, custom and practice, stimulated in particular by significant landmark fire events. The ways of making fire safety provisions, and the recommended guidance, varies, but the underpinning principles remain the same. The first priority is safety of the occupants and sure protection for firefighters. Second comes protection of the property and assets, an increasing need since fire can have tremendous economic impact on local communities, through its affect on jobs, businesses and public buildings such as hospitals, residential homes for the elderly, and schools. Fire does not only have a human dimension. There are economic, social, and environmental aspects as well. There are good reasons for wanting good fire safety regulation, and especially appropriate enforcement. Specifying fire resistance Given the complexities of fire and the various possible fire safety objectives, it is not sufficient to simply specify fire resistance. Fire resistance has to be defined. Standards commonly recognise two basic classifications, which for any qualifying product must be checked by test in a specified fire-resistant system. These categories are a) integrity, i.e. acting merely as a physical barrier to simply hold back flames and hot gases, and b) insulation, which requires integrity plus the ability to prevent significant heat transfer from the fire and flames (by all mechanisms: radiation, conduction, convection). Similarly, the general term fire protection can also cause confusion and misconception, especially between fire resistance and fire retardancy. The fire retardant property applies entirely separately to spread of flame and the ability of a material to sustain burning. Intermediate fire resistance options may also only serve to blur distinctions. An example is the European class EW which allows classification up to a measured radiant heat level of 15kW/sqm at 1 metre distance. Only one country in Europe uses this class in its regulations. In fact 15kW/sqm is a high level of radiant heat readily understandable if it is remembered as being equivalent to around 15 times the maximum sun s intensity at mid summer on the earth s surface, capable of causing serious burns in a fraction of minutes. The limit to protect people is 2.5 kw/sqm, i.e. insulation performance. One of the reasons for the 15 kw/sqm provision in the classification scheme is a presumption that this generally limits the risk of ignition on the nonfire side. This may be the case for some materials, but not necessarily all. But what the 15 kw/sqm level hardly limits is the risk of smouldering combustion on the non fire side (without flaming), generating smoke in the protected zone. And it is smoke and fumes which cause many deaths in fire. Critical importance of insulation Because heat is one of the most dangerous aspects of fire, integrity with limited or no ability 38 INTERNATIONAL FIRE PROTECTION

PROGRESS WITH FIRE-RESISTANT GLASS FIRE-RESISTANT GLASS to attenuate heat has restricted application. That is, for example, before the fire conditions become untenable, i.e. in the early stages of escape within the first minutes of the fire alarm being sounded, or for smoke screens in the absence of flames. In contrast, insulation plus integrity has the ability to provide far more robust fire protection over time, also providing excellent protection against heat which may otherwise cause serious lifethreatening burns. Insulation performance may therefore offer particular advantages for enhanced life safety (especially for vulnerable groups) as well as benefits in limiting fire spread by secondary ignition on the protected side of the glazing. Confidence in performance One of the most important questions facing specifiers and designers concerning fire is product reliability. Does the product performance in a test reflect likely performance in a fire? Does a pass in one test mean a pass should the test be repeated? Does an individual furnace test reflect routine production quality, or is it a special quality? The main purpose of testing is to allow product classification. The test is formulised to represent a standard, fixed fire condition. Yet in practice there is no standard fire: fire is essentially unpredictable and variable with infinite capacity to surprise. Chance circumstance may determine outcome in a way that cannot be foreseen at design. A single fire test, it should be remembered, only provides information on the system as provided and tested on the day of the test, as installed on that day. Installations should replicate the original tested specification. A single test simply allows classification, and only provides an indication of tendency. Important considerations that allow better judgment on risks in real fires are not recorded nor offered, for example a description of the change mechanism under fire exposure. If wider assurance and confidence in the level of performance is sought then the wider picture needs to be obtained. That evaluation should include the fundamental characteristics of the particular fire-resistant glass technology being used. this criterion. Internal checks and control processes are also important. The governing attitude should be test, test and test again, not only in official tests but also by the discipline of internal furnace testing and product control. For example, Pilkington operates four full size furnace test facilities in regular use, with facility to evaluate both oil and gas firing, including the capability to test elements up to size 4m by 4m. Natural selection One of the most important considerations in evaluating risk in a fire is to understand the mode and mechanism of failure under fire exposure. The necessary level of confidence in a product can only come from a good pedigree of furnace testing, as diverse and varied as possible, together with an open explanation of the mechanism of deterioration in fire together with explanation of the fundamental strengths of the technology that counterbalance that mechanism. For example, there is a world of difference between catastrophic, unpredictable failure (which is essentially an unreliable failure mode, e.g. as characteristic of toughened glass in fire), and one that is based on gradual and progressive deterioration, which is predictable and therefore controllable through product design (e.g. as applies to intumescent sodium silicate based laminated fire-resistant technology, as used and extensively tested over many years in the first of this type Pilkington Pyrostop and Pilkington Pyrodur ). All materials, sooner or later, fail in fire. The product that recognises that, and adjusts accordingly in its underlying technology and design, is the one that provides the natural choice for security and peace of mind. Pointers to reliability The first point of reference is the test record not only the extent of testing and success rate, but also if test failures are experienced and why. The range and number of test approvals is a significant guide: different applications and situations, number of framing options, the complexity of the glazing arrays, and the size of the glazing panels tested are all useful indicators. It is valid to ask how many approvals have been gained, in how many different test laboratories under different testing regimes, as well as the number, range and variety of systems that have successfully gained official test approval. Additional product certification e.g. international and national marks, such as CE marking, UL approval, and third party schemes are also useful indicators. It s the responsibility of manufacturers to take all measures that they can to check the fitness for purpose of their products. A basically sound and robust fire-resistant glass technology is needed, that can respond in real fire situations to the unpredictable challenges set by fire. Not all fireresistant glass technologies may measure up to INTERNATIONAL FIRE PROTECTION 39

PROGRESS WITH FIRE-RESISTANT GLASS Range of application The use of fire-resistant glass is now extensive, providing plenty of options. Interior applications include vision panels, full glass doors and doorsets, large area glazed partitions or separating walls, and privacy glazing with integral blind systems. Even some fire-resistant glazed sliding door systems are available. For the older heritage building, secondary fire-resistant glazing systems may be appropriate to provide the fire protection function whilst preserving the character of the original casements. The widespread use of atria in designs has also led to some interesting fire-resistant solutions, especially in the side glazing for major atria to prevent fire break out from the adjoining rooms looking out into the atrium. The latest innovation is integral load-bearing fire-resistant glass floors in one composite structure which critically require insulation fire-resistant glass to limit heat transfer into the structure and preserve structural stability. External applications include not only the vertical façade elements to minimise the risk of fire transfer to adjacent buildings or escape ways, but also composite overhead glazings for horizontal or inclined roof applications to allow the maximum light penetration into the building, also fulfilling the safety requirements for overhead. The designer now has many available options to realise innovative and open design without compromising fire safety (whilst providing other critical functions such as energy efficiency, security and acoustic comfort). One of the most important and growing applications is the use of external fire-resistant glazing to prevent fire movement outside the building, since break out followed by break in on adjacent levels is especially one of the most sensitive fire risks for the tall and complex buildings that now dominate city skylines. guidance is to be sidelined more and more by expert judgment and functional design then it is even more critical that products and technologies are clearly understood. Fire-resistant glass cannot be treated generically. And relying just on a single fire test, or a limited range, is not enough. Each fire-resistant glass needs to be evaluated on its own merits. Risk can only be properly evaluated, and related to real fire conditions, if the failure mode is taken into account in specification decision making. That means using a robust and resilient fire-resistant glass technology, one that has an inherently reliable and repeatable function. If seeking to limit risk and minimise uncertainty in real fires is the way forward, then there needs to be a greater focus on behaviour under real fire conditions and less of a tendency to take products just at face value. IFP The future: risk and intelligent design The risk-based approach to fire safety design is becoming more popular as an alternative to prescription. Complex and individual building designs call for fire safety design tailored to suit the building s occupancy profile, performance specification and layout. If prescriptive regulatory 40 INTERNATIONAL FIRE PROTECTION