NVx Suspended Gas Unit Heater Range



Similar documents
Product Overview Benefits

UDSA - UDSBD unit heater

Gas Unit Heaters Duct Furnaces Horizontal - 60 HZ Form No. LF (10/2011) LF24 Standard

HEAVY DUTY STORAGE GAS

SECTION PACKAGED ROOFTOP AIR CONDITIONING UNITS NON-CUSTOM

NAVIEN AMERICA INC FITCH AVENUE

Cabinet heater. Gas fired cabinet heater with atmospheric burner for indoors installation for free blowing applications or connection to ductwork

M7RL Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. High Efficiency / Direct Vent Condensing Downflow Gas Furnace

Commercial Gas Furnace Upflow

G26 Corp L11 Revised LENNOXOEMPARTS.COM. Service Literature G26 SERIES UNITS

only Energy saving boiler technology at its best

Frequently Asked Questions. Air Top Diesel Heaters. 2000STC, Evo 40 & Evo 55

T One. 5year. Energy saving boiler technology at its best. moving parts.

Elegant ECM. ELEGANT ECM air conditioners allow. The range is made up of 12 models: Ceiling Air Conditioner

TECHNICAL GUIDE 95.5% SINGLE STAGE GAS-FIRED RESIDENTIAL MULTI-POSITION GAS FURNACES MODELS: TG9S DESCRIPTION FEATURES

The Concept. How Cassettair can benefit you. Applications. Selecting Cassettair

"EC" Series Electric Humidifier

squrboxbox heat recovery squrboxbox I technical information

RPV - RP - RA air handling units

Portable Air Conditioner

SECTION HEATING, VENTILATION AND AIR CONDITIONING EQUIPMENT

AZB 800. Vertical Flue Gas Ducting Ø60/100mm

Cooling Capacity CFM in. w.c. (125 Pa)

RKE. Heat recovery unit. heat recovery unit RKE. from 200 to 6800 m 3 /h. General features

Operating instructions

GC 3 (PF) (THREE OVEN) GAS FIRED POWER FLUE COOKER

Cooling Capacity CFM in. w.c. (125 Pa)

CADB and CADT-D / DI / DC Series

Quinta Range. Condensing Boilers REMEHA QUINTA RANGE. High efficiency wall hung condensing boiler with ultra low NOx emission

hore PRODUCT CATALOGUE nd Offsh arine an ms for Ma & Refrig AUTONOMOUS AIR CONDITIONERS HV VAC &

GREENSTAR 60/100 HORIZONTAL FLUE

Installation Instructions

ASX7-4-IOM-7 J

COMMERCIAL COOKING HOODS, VENTILATION & FIRE SUPPRESSION SYSTEM GUIDELINES AND PROCEDURES

Explosion-Proof Electric Unit Heaters

Spray Booth Guideline

Residential/Commercial Gas Condensing High Efficiency Tankless Water Heaters

Aludesign K A T A L O G

San josé OWNER S MANUAL

UHIR Series. Horizontal or Vertical Mounting Industrial / Commercial Electric Unit Heater. Owner s Manual

USERS GUIDE. LOGIC Heat 12, 15, 18, 24, 30. For installation guide see reverse of book

F9MXE. Product Specifications

SPARE PARTS EXPLODED VIEW GAS WALL BOILERS Model GENUS PREMIUM FS CUENOD. R EN - Edition 01-26/10/2009

Cooling Capacity CFM in. w.c. (125 Pa)

USERS GUIDE. LOGIC Combi 24, 30, 35. For installation guide see reverse of book

How To Design A Gas Dryer

Diesel Engine Exhaust Spark Arrestors Selection, Application and Maintenance

FTQ. Daikin Inverter Ducted Heat Pump

Invisidor STYLE Air Curtain

High Efficiency Boiler Range Technical Guide

Stove-boiler for solid fuels KW Directions for use and assembling

Response: The combi boiler. Response: The fit anywhere combi

Owner Retain this manual in a safe place to provide your serviceman information if it becomes necessary.

1-Way Chilled Water Cassettes KCO 60, 90 & 120. Technical Brochure. TM KCO-W.1GB Date : November 2005 Supersedes : None

orlando OWNER S MANUAL

For installation guide see reverse of book


HOT WATER SYSTEMS.

O. Gas boiler. Gaz 6000 W WBN H-E-N/L-S2400. Operating instructions for the end customer (2014/07) en

Industrial infrared heater IR For premises with large volumes and high ceilings

THC 85 INDUSTRIAL / COMMERCIAL SPACE HEATER

CRAC Precision climate control units for data centres

Heating with wood chips and pellets

Part 3 Ancillary technologies. Chapter 3.2. Mechanical ventilation with heat recovery

INNOVATIVE SOLUTION OF DOMESTIC HEATING SPLIT TYPE SPLIT DHW INTEGRATED TYPE MONOBLOC TYPE

Operating instructions

ecomax Instructions for use Wall hung room sealed fan assisted condensing boilers For the user

Eurovacuum EV Series. Single Stage Oil Sealed Rotary Vane Pump

ferroli Boiler Replacement Optimax HE- Modena HE

Morco House Riverview Road Beverley HU17 0LD. Retrofit or Upgrade a Water Heater in a Caravan Holiday home

Johnson Air-Rotation Systems

PANDA SPRAY BOOTH FILTER INFORMATION

Baxi Combi 80e & 105e

RECON WATER HEATER INSTALLATION FORM

CE6500 Energy Recovery Ventilator

User's Instructions. Alpha HE CB25/33 and HE SY25

Figure 22: Typical Individual Venting. Figure 21: Single Water Heater Venting

Operating instructions

Heating and Hot Water Services Controls General Technical Specification

USER S, MAINTENANCE and SERVICE INFORMATION MANUAL

Series GM. Peerless Boilers. Residential/Commercial Gas Boilers

Spare Parts List M96A.24SM/B M96A.28SM/B

Direct steam injection humidifiers

ECOCIAT. Domestic hot water heat recovery unit

SL280UHV SERIES GAS FURNACE WARNING

Replacement parts. WM97+ gas-fired water boiler Boiler Manual. OBTAIN PARTS ONLY THROUGH WEIL-McLAIN THE BOILER CONTAINS CERAMIC FIBER MATERIALS

1 DESCRIPTION OF THE APPLIANCE

ThermoStar Refrigeration Air Dryers

GTS. New! Plus: PR0DUCT CATALOG. Vapor-logic 4 controller with: and LonTalk. New models GTS-500 and GTS-700. Gas-to-Steam Humidification System

PLAN SUBMITTAL REQUIREMENTS FOR SPRAY BOOTHS AND SPRAYING ROOMS EXTINGUISHING SYSTEMS

HDA

SELECTION, APPLICATION AND MAINTENANCE

Apartment and Communal Heating Solutions

TWE+TTA TWE+TWA T.R.

MAJESTIC. OUTDOOR / INDOOR WOOD FIREPLACES Model: ODSR36A OWNERS INSTALLATION & OPERATING INSTRUCTIONS. KEEP THESE INSTRUCTIONS FOR FUTURE REFERANCE.

Decree of the Ministry of the Environment on fire safety of ventilation systems

SECTION PACKAGED ROOFTOP AIR CONDITIONING UNITS

Heating, Ventilation, Air Conditioning and Refrigeration (HVACR)

The space saving solution.

HeatSource HS1800 Heater

Transcription:

NVx Suspended as Unit Heater Range Industrial & ommercial Heating Systems. www.powrmatic.co.uk HTIN // VNTILTION // IR ONITIONIN // O PROUTS

NVx Overview odels vailable NVx - xial an rossflow Units NVx uo - xial an i-irectional Units NVx V - xial an ownflow Units NVx - entrifugal lose oupled an Units NVx - ucted Heat odule (no fan) Installer riendly urners ulti in-shot burners matched to each tube assembly and manifolded to a common gas valve and ignition system, itself complete with flame monitoring and safety controls and supplied ready for use with natural gas (20). lternative LP propane (31) firing available to order. ir ovement xial fan heaters are, dependent upon model, fitted with either single of multiple fan sets and discharge warmed air directly into the heated space via adjustable louvred horizontal grilles. entrifugal fan models are fitted with the centrifugal fan mounted directly to the heater and discharge via a duct outlet spigot mounted to the front of the heater. New compact model ownflow & bi-directional models available Horizontal wall exit flue discharge option (no roof work) an assisted flue that can be room sealed Interchangeable top or rear flue/combustion air spigot positions entrifugal fan option Peace Of ind ore Than Sixty Years xperience in Warm ir 2 Year Parts nd One Year Labour uarantee 10 Year Sliding Scale Time Related Heat xchanger Warranty pplication and onfiguration The NVx range of gas fired unit heaters comprises 13 models with outputs ranging from 10 kw to 140 kw. The heaters are typically installed directly into the space to be heated with ducted applications satisfied using the centrifugal fan option. Suitable for either natural or LP gases, heaters can be specified/arranged for on/off, high/low or modulated heat outputs. fficiencies avourable levels of fuel usage and reduced emissions are a key element of NVx heater design. dditionally, all heaters have efficiencies which meet or exceed the requirements of current uilding Regulations. fficiencies can be further enhanced with the selection of the modulating burner option. abinet The heater unit is of unitary construction and provided with a separate compartment with a full width hinged and lift-off door giving easy access to heater function controls, gas valve and burner. The cabinet is finished with durable epoxy powder coat stove baked paint. Heat xchanger our pass tubular assembly manufactured from aluminised steel formed, swaged and expanded without recourse to stress inducing welding. 409 and 316 grade stainless steel options available. ontrols s standard, Powrmatic heaters are supplied with high temperature limit protection as well as connections for heat and, where applicable, fan-only operation. or enhanced control the heaters may be connected to one of our compatible environmental control stations. These are available in three options: 200L (control of single units) Tamper-proof digital control featuring optimised start/stop, digital time switch, electronic and frost protection thermostats. Remote temperature sensor option available. 300 ulti (control of multiple units) The 300 multi is functionally identical to the 200L with the added ability to control up to five heaters from a master 300 control. or ease of installation and to reduce installation time and cost slave pcbs are factory fitted with connections between master and slave enabled with low voltage control cable. Powrtrol (control of single units) s an alternative to the control units, Powrtrol control stations provide a digital time switch with mechanical day and frost protection thermostats and a switched fan-only option for summer operation. Heaters controlled using Powrtrol do not qualify for nhanced apital llowances. Note: Interconnecting wiring for all controls is the responsibility of the installer. Visit www.powrmatic.co.uk for more information. pprovals ll Powrmatic heaters are type tested to meet the stringent requirements the as irective and are approved. 2

uties irflow Volume irflow lectrics uel ounting Height odel 10 15 20 25 30 40 50 60 75 90S 90 120 140 Output kw 10 15 20 25 30 40 50 60 75 90 90 120 140 Input (nett V) kw 10.79 16.00 21.85 27.32 32.60 43.48 54.23 65.60 81.30 97.80 95.30 130.1 148.9 NVx / / V m 3 /s 0.26 0.39 0.52 0.65 0.78 1.00 1.30 1.56 1.95 2.34 2.34 3.12 3.64 uo m 3 /s N/ N/ N/ N/ N/ N/ N/ N/ N/ N/ 2.34 3.12 3.64 NVx in m 3 /s 0.21 0.31 0.42 0.52 0.63 0.83 1.04 1.25 1.56 N/ 1.88 2.50 2.92 ax m 3 /s 0.28 0.42 0.56 0.69 0.83 1.11 1.39 1.67 2.08 N/ 2.50 3.33 3.89 Throw NVx m 7.0 10.0 13.0 16.0 15.0 21.0 24.0 25.0 29.0 38.0 31.0 35.0 37.0 NVx uo m N/ N/ N/ N/ N/ N/ N/ N/ N/ N/ 48.0 50.0 58.0 an Static NVx Pa 140 145 177 143 250 236 205 250 260 N/ 200 284 285 Supply Standard V/ph/Hz 230/1/50 Optional V/ph/Hz 415/3/50 (entrifugal Unit Only) NVx otor kw 0.04 0.12 0.07 0.19 0.19 0.30 0.46 0.68 0.68 0.90 Start amp 0.34 1.00 0.38 2.0 2.0 2.60 5.30 5.50 5.50 6.48 11.0 11.0 11.0 Run amp 0.16 0.37 0.28 0.64 0.63 1.02 1.80 2.40 2.40 3.60 3.70 4.85 4.90 otor kw 0.25 0.25 0.37 0.37 1.10 1.10 1.10 1.40 1.40 N/ NVx Start amp 4.20 4.50 12.60 12.60 18.50 18.50 18.50 28.90 28.90 N/ 31.00 40.00 40.00 Run amp 2.10 1.50 4.20 4.20 6.40 6.40 6.40 12.50 12.50 N/ 12.80 25.00 25.00 onnection SP/Rc ¾ inimum Inlet Pressure onsumption NVx /uo rossflow NVx V ownflow Nat as mbar 17.5 LP mbar 37.0 Nat as m 3 /h 1.14 1.69 2.31 2.89 3.45 4.60 5.73 6.93 8.59 10.35 10.07 13.77 15.74 LP m 3 /h 0.44 0.65 0.89 1.12 1.33 1.61 2.22 2.67 3.32 4.00 3.90 5.17 6.09 in m 2.50 3.00 ax m 3.00 5.00 in m 3.00 4.00 4.00 5.00 N/ 6.00 6.00 ax m 5.00 6.00 7.00 8.00 N/ 10.00 12.00 Height mm 540 540 540 540 760 760 912 760 912 975 700 831 975 Overall ims NVx Width mm 785 1000 1000 1000 1000 1000 1000 1325 1325 1575 2325 2325 2325 epth mm 700 700 700 700 700 700 700 700 700 700 700 700 700 Top mm 200 Install LH Side mm 200 NVx learance RH Side mm 1000 Rear mm 400 iameter mm Ø 80 80 80 80 100 100 100 130 130 130 130 130 130 lue ax lue Only m 12 Length Room Sealed m 6 ombustion ir Spigot mm Ø 80 80 80 80 100 100 100 130 130 130 130 130 130 Noise Levels NVx d() 46 54 52 53 54 58 61 62 62 76 66 67 67 NVx kg 53 69.5 69.5 74.5 96 108 123 138.5 158 203 204 260 280 Nett Weight Notes: NVx kg 91.5 106.5 120.5 126.5 166.5 168.5 183 213 234 N/ 343 363.5 424 uel onsumption and input figures based upon nett calorific values as follows: - Natural as (20) nett V 34.02 J/m 3 - Propane (31) nett V 88.00 J/m 3 Heaters have efficiency levels which meet with the minimum efficiency requirements of UK PartL2 uilding Regulations ir handling data is assessed at room ambient conditions Throw figures provide the distance to the point where the terminal velocity degrades to 0.25m/s imensions and clearance data in the table above refer to NVx units only - for NVx and NVx data refer to the dimensions page and/or the installation instructions Noise levels are applicable to standard NVx models and are measured 5m from appliance in a typical installation situation. otor kw, run and start amps apply to standard electrical supply as stated. or optional data contact sales office onnection of combustion air duct is not required for flue only applications The NVx uo throw dimension is the effective combined throw measurement It is the responsibility of the installing contractor to ensure that ductwork is correctly sized and balanced when installing NVx entrifugal units Installer guidance notes on rear page 2 x 0.46 2 x 1.10 2 x 0.68 2 x 1.40 2 x 0.68 2 x 1.40 3

imensions NVx - xial an rossflow Units NVx 75 NVx 120 L ø P RONT VIW 35 R/H SI VIW N L NTRY S NTRY POINT RR VIW SUSPNSION POINTS 10 228 TRS 228 TRS NVx 10-90s PLN 228 TRS 228 TRS NVx 90-140 PLN K J TRS H K J TRS J TRS H NOT: or dimensioning purposes both top and rear flue and combustion air connections are shown odel 10 15 20 25 30 40 50 60 75 90S 90 120 140 mm 785 1000 1000 1000 1000 1000 1000 1325 1325 1575 2325 2325 2325 mm 700 700 700 700 700 700 700 700 700 700 700 700 700 mm 540 540 540 540 760 760 912 760 912 975 700 831 975 Ø mm 80 80 80 80 100 100 100 130 130 130 130 130 130 mm 248 248 248 248 233.5 233.5 233.5 235.5 235.5 235.5 235.5 235.5 235.5 mm 308 308 308 308 492 492 644 416 568 631 356 487 631 mm 120 120 120 120 142 142 142 220 220 220 220 220 220 H mm 317 317 317 317 317 317 317 347 347 347 347 347 347 J mm 250 250 450 450 450 450 450 700 700 950 850 850 850 K mm 218 232.5 232.5 232.5 232.5 232.5 232.5 278 278 278 278 278 278 L mm 915 915 915 915 915 915 915 915 915 915 915 915 915 mm 216 216 216 216 206 206 206 236 236 246 246 246 246 N mm 114 114 114 114 114 114 114 145 145 88 88 88 88 P mm 194 194 194 194 297 297 374 297 374 398 260 326 398 4

imensions NVx uo - xial an i-irectional Units NVx 120 uo L Ø RONT VIW 35 R/H SI VIW SUSPNSION POINTS 10 228 TRS PLN P 228 TRS N S NTRY POINT RR VIW L NTRY K J TRS J TRS H NOT: or dimensioning purposes both top and rear flue and combustion air connections are shown odel 90 120 140 mm 2325 2325 2325 mm 700 700 700 mm 700 831 975 Ø mm 130 130 130 mm 235.5 235.5 235.5 mm 356 487 631 mm 220 220 220 H mm 347 347 347 J mm 850 850 850 K mm 278 278 278 L mm 1120 1120 1120 mm 246 246 246 N mm 88 88 88 P mm 260 326 398 5

imensions NVx V - xial an ownflow Units NVx 60 V NVx 60 V Ø + 70mm L RONT R/H SI VIW RR VIW ROP RO SUSPNSION POINTS 10 K J TRS J TRS H N K J TRS J TRS J TRS J TRS H N L NTRY P P + 30mm + 30mm S NTRY POINT PLN OR NVx V 10-75 PLN OR NVx V 90-140 NOT: or dimensioning purposes both top and rear flue and combustion air connections are shown odel 10 15 20 25 30 40 50 60 75 90 120 140 mm 785 1000 1000 1000 1000 1000 1000 1325 1325 2325 2325 2325 mm 700 700 700 700 700 700 700 700 700 700 700 700 mm 540 540 540 540 760 760 912 760 912 700 831 975 Ø mm 80 80 80 80 100 100 100 130 130 130 130 130 mm 248 248 248 248 233.5 233.5 233.5 235.5 235.5 235.5 235.5 235.5 mm 308 308 308 308 492 492 644 416 568 356 487 631 mm 120 120 120 120 142 142 142 220 220 220 220 220 H mm 282 283 283 304 283 283 283 312 312 299 350 312 J mm 320 260 260 260 260 260 260 385 385 442.5 442.5 442.5 K mm 183 197 197 176 197 197 197 243 243 256 205 243 L mm 915 915 915 915 915 915 915 915 915 915 915 915 mm 216 216 216 216 206 206 206 236 236 246 246 246 N mm 114 114 114 114 114 114 114 145 145 88 88 88 P mm 194 194 194 194 297 297 374 297 374 260 326 398 6

imensions NVx - entrifugal lose oupled an Units NVx 50 (ront) ø NVx 50 (Rear) T P S 35 L N S NTRY POINT RONT VIW R/H SI VIW L NTRY RR VIW NOT: or dimensioning purposes both top and rear flue and combustion air connections are shown SUSPNSION POINTS 10 228 TRS 228 TRS PLN OR NVx 10-75 228 TRS 228 TRS PLN OR NVx 90-140 K J TRS H K J TRS J TRS H odel 10 15 20 25 30 40 50 60 75 90 120 140 mm 785 1000 1000 1000 1000 1000 1000 1325 1325 2325 2325 2325 mm 700 700 700 700 700 700 700 700 700 700 700 700 mm 540 540 540 540 760 760 912 760 912 700 831 975 Ø mm 80 80 80 80 100 100 100 130 130 130 130 130 mm 248 248 248 248 233.5 233.5 233.5 235.5 235.5 235.5 235.5 235.5 mm 308 308 308 308 492 492 644 416 568 356 487 631 mm 120 120 120 120 142 142 142 220 220 220 220 220 H mm 317 317 317 317 317 317 317 347 347 347 347 347 J mm 250 250 450 450 450 450 450 700 700 850 850 850 K mm 218 232.5 232.5 232.5 232.5 232.5 232.5 278 278 278 278 278 L mm 1317 1317 1356 1356 1430 1430 1430 1515 1515 1430 1515 1515 mm 216 216 216 216 206 206 206 236 236 246 246 246 N mm 114 114 114 114 114 114 114 145 145 88 88 88 P mm 194 194 194 194 297 297 374 297 374 243 326 398 S mm 422 637 637 637 637 637 637 932 932 1932 1932 1932 T mm 492 492 492 492 712 712 864 712 864 651 783 927 7

imensions NVx - ucted Heat odule (No an) NVx 50 (ront) NVx 50 (Rear) L ø T T P S RONT VIW 33.7 R/H SI VIW 33.7 N S NTRY POINT S RR VIW L NTRY SUSPNSION POINTS 10 228 TRS 228 TRS PLN OR NVx 10-75 228 TRS 228 TRS PLN OR NVx 90-140 K J TRS H K J TRS J TRS H NOT: or dimensioning purposes both top and rear flue and combustion air connections are shown odel 10 15 20 25 30 40 50 60 75 90 120 140 mm 785 1000 1000 1000 1000 1000 1000 1325 1325 2325 2325 2325 mm 700 700 700 700 700 700 700 700 700 700 700 700 mm 540 540 540 540 760 760 912 760 912 700 831 975 Ø mm 80 80 80 80 100 100 100 130 130 130 130 130 mm 248 248 248 248 233.5 233.5 233.5 235.5 235.5 235.5 235.5 235.5 mm 308 308 308 308 492 492 644 416 568 356 487 631 mm 120 120 120 120 142 142 142 220 220 220 220 220 H mm 317 317 317 317 317 317 317 347 347 347 347 347 J mm 250 250 450 450 450 450 450 700 700 850 850 850 K mm 218 218 232.5 232.5 232.5 232.5 232.5 278 278 278 278 278 L mm 835 835 835 835 835 835 835 835 835 835 835 835 mm 216 216 216 216 206 206 206 236 236 246 246 246 N mm 114 114 114 114 114 114 114 145 145 88 88 88 P mm 194 194 194 194 297 297 374 297 374 260 326 398 S mm 422 637 637 637 637 637 637 932 932 1932 1932 1932 T mm 492 492 492 492 712 712 864 712 864 651 783 927 8

lue rrangements Room Sealed - Horizontal lue System Room Sealed - Vertical lue System Terminal lue socket Lengths Single to twin adaptor Terminal lashing djustable length ombustion air socket ombustion air duct 6m maximum lue Only- Horizontal lue System Notes for all systems: 1. inal overall length of adjustable disconnection piece must be between 360-415mm. 2. 45 offsets may be used if required. ach set is equivalent to 0.5m of flue length. 3. 90 offsets may be used if required. ach set is equivalent to 1m of flue length 4. Where NVx heaters are used in clean environments it is permissible to take the combustion air directly from the heated space. The supplied mesh intake plate must be fitted to the combustion air inlet on the rear of the heater. 5. If fitted with vertical flue, Powrmatic recommend the installation of a condensate drain length. Single to twin adaptor Lengths ombustion air socket Terminal djustable lengths lue socket 6m maximum ondensate drain length lue Only- Vertical lue System ombustion air entry (fitted with inlet grille) lue socket djustable length Lengths Terminal lashing 12m maximum Lengths ombustion air entry (fitted with inlet grille) 12m maximum lue omponents ombustion air entry (fitted with inlet grille) djustable length ondensate drain length lue socket ombustion air entry (fitted with inlet grille) oncentric Vertical Terminal Kit Unit Part Number mm mm mm mm mm 130mm (NVx60-140) NVx 10-25 NV/VTK1 80 605 105 630 130 NVx 30-50 NV/VTK2 100 550 145 770 150 NVx 60-140 NV/VTK3 130 960 250 560 200 80-100mm (NVx10-50) oncentric Horizontal Terminal Kit Unit Part Number mm mm mm mm mm NVx 10-25 NV/HTK1 80 175 105 560 130 NVx 30-50 NV/HTK2 100 170 145 560 150 NVx 60-140 NV/HTK3 130 185 250 420 200 80-100mm (NVx10-50) 130mm (NVx60-140) 9

ccessories 30 ownflow Head (NVx odels Only) odel NVx 10 496 449 425 350 352 NVx 15-20-25 496 449 639 350 494 NVx 30-40 716 559 639 560 494 NVx 50 868 635 639 630 494 NVx 60 716 559 934 500 659 NVx 75 868 635 934 630 659 NVx 90 656 528 1934 420 659 NVx 120 787 595 1934 560 659 NVx 140 931 667 1934 700 659 90 ownflow Head - (NVx odels Only) odel NVx 10 496 601 425 350 352 NVx 15-20-25 496 601 639 350 494 NVx 30-40 716 862 639 560 494 NVx 50 868 1015 639 630 494 NVx 60 716 862 934 500 659 NVx 75 868 1015 934 630 659 NVx 90 656 802 1934 420 659 NVx 120 787 932 1934 560 659 NVx 140 931 1076 1934 700 659 ixing ox - (NVx odels Only) odel NVx 10 865 745 502 432 520 590 NVx 15-20-25 865 745 698 628 520 590 NVx 30-40 1093 973 698 628 748 818 NVx 50 1247 1125 698 628 900 970 NVx 60 1093 973 1011 941 748 818 NVx 75 1247 1125 1011 941 900 970 NVx 90 980 860 2014 1944 635 705 NVx 120 1145 1025 2014 1944 800 870 NVx 140 1310 1190 2014 1944 965 1035 ilter ox - (NVx odels Only) odel NVx 10 502 590 120 432 522 NVx 15-20-25 698 590 120 628 522 NVx 30-40 698 818 120 628 750 NVx 50 698 970 120 628 902 NVx 60 1010 818 120 940 750 NVx 75 1010 970 120 940 902 NVx 90 2014 705 120 1944 637 NVx 120 2014 870 120 1944 802 NVx 140 2014 1035 120 1944 967 10

an Plenum ox - (NVx odels Only) odel NVx 10 643 510 575 494 429 NVx 15 643 725 575 494 644 NVx 20-25 750 725 575 494 644 NVx 30-40 750 725 795 714 644 NVx 50 750 725 947 866 644 NVx 60 750 1020 795 714 939 NVx 75 825 1020 947 866 939 NVx 90 825 2021 735 654 1940 NVx 120 825 2021 866 785 1940 NVx 140 825 2021 1010 929 1940 Vertical Louvres (or Use On ll odels) odel NVx 10 395 418 66 NVx 15-20-25 537 418 66 NVx 30-40 537 628 66 NVx 50 537 698 66 NVx 60 702 568 66 NVx 75 702 698 66 NVx 90 702 493 66 NVx 120 702 628 66 NVx 140 702 758 66 Swivel Wall racket - ( NVx odels Only) antilever Wall racket - (NVx odels Only) 105 500 474 500 100 Heater Heater Notes: - imensions for the swivel and cantilever brackets remain the same for all NVx models - Swivel rackets can not be used with double units ontrols choice of control options are available for the NVx range. 5 heaters can now be controlled using the new 300 ulti from a single master control. Visit our website to find out more about our controls systems. 200 300 ulti Powrtrol/RR RR Relay oxes Single Unit ontrols ultiple connectivity of up to 5 heaters from a master 300 unit with each heater factory fiited with a 300 slave. Single Unit ontrols RR2 shown - control up to 2 units. Other RR relay boxes available to control up to 4 to 6 units. 11

Your Installer uide eneral The following notes are provided as a guide, however installers and operators should fully acquaint themselves with the more detailed guidance provided in the relevant installation manual. or copies of such manuals please consult our technical department or visit our website - www.powrmatic.co.uk Standards ll Powrmatic NVx heaters must be installed, commissioned and operated with due regard to appropriate regulations including but not limited to S 6230, relevant odes of Practice, the possible requirements of Local uthorities, ire Officers and insurers as well as Powrmatic s installation manual. Position & Location Powrmatic NVx heaters can be drop rod suspended via purpose designed 10 suspension fixing points, attached to our optional wall support brackets or positioned on a level non-combustible base. In all cases it is important that all supporting structures have due regard to the relevant weight loadings. onsideration should also be given to flue routes and points of exit, gas, electrical and control connections, the throw characteristics of the heater, issues of public access and the siting of environmental control stations and/or remote temperature sensors where the position needs to be representative of the zone temperature to which they refer. Heaters should not be installed in hazardous areas or areas where there is a foreseeable risk of flammable or corrosion inducing particles, gases or vapours being drawn into the combustion air or main fan circuits. reas where special consideration or advice may be required could include but is not limited to - Where de-greasing solvents are present, even in minute concentrations Where paint spraying is carried out Where styrenes or other laminating products are used Where airborne silicone is present Where petrol engined vehicles are stored or maintained Where dust is present (i.e. wood working or joinery shops) Where high levels of extract persist Installation in such areas may be possible under specific conditions. Please consult our technical department for further information. Plant Room or nclosure Locations It is recommended that you consult with our technical department. Powrmatic Limited Hort ridge Ilminster Somerset T19 9PS tel: +44 (0) 1460 53535 fax: +44 (0) 1460 52341 e-mail: info@powrmatic.co.uk web: www.powrmatic.co.uk ombustion ir & eneral Ventilation Within the United Kingdom mandatory regulations apply concerning the provision of combustion air and general heater ventilation. Where a heater is installed in room sealed mode (i.e. where both the flue exit and combustion air and positively connected to atmosphere) then there is no specific requirement for combustion air ventilation. However, depending upon location, provision for general ventilation may still be a necessity. If the heater is installed in flue only mode and directly within the heated space and where that heated space has a natural ventilation rate greater than 0.5 air changes per hour then combustion air and general heater ventilation is probably not required. If the heated space has a natural ventilation rate of less than 0.5 air changes per hour then either natural ventilator openings or mechanical ventilation will be required. Please consult the installation manual for further details. Installation learances Particular clearances may be necessary for the correct and safe function of the heater as well as for maintenance purposes. Such clearances are confirmed in the relevant installation manual. lue Powrmatic NVx heaters can be installed in either room sealed or flue only mode. ach heater requires a separate flue and/or combustion air intake system of the appropriate size and type. Installers are reminded that type approval has been granted for these appliances on the basis that they are fitted with Powrmatic NVx flue systems. aximum lengths apply and should be strictly observed. Systems may be installed in either the horizontal or vertical plane. In either case the number of bends kept to a minimum and regard must be given to the reduction in permissible length with the addition of each bend. The flue must be adequately supported and terminated with the approved terminal assembly, with due regard to the point of exit and it s proximity to any windows, doors or ventilation intakes etc. Pipework are should be taken when sizing pipe work to ensure that minimum gas inlet pressures are not compromised under dynamic load conditions. Isolating valves and service unions should be provided for each heater and pipe work installed with due regard for relevant standards and odes of Practice. uarantee Powrmatic NVx heaters are provided with a comprehensive guarantee covering both the heater and the heat exchanger. or United Kingdom sales the heater has the benefit of a two year parts and one year labour guarantee whilst the heat exchanger assembly has a ten year time related sliding scale warranty. ll guarantees are subject to terms and conditions. Powrmatic Ireland 45 roomhill lose Tallaght ublin 24 tel: +353 (0) 1452 1533 fax: +353 (0) 1452 1764 e-mail: info@powrmatic.ie web: www.powrmatic.ie Powrmatic pursues a policy of continuous improvement in both design and performance of its products and therefore reserves the right to change, amend or vary specifications without notice. Whilst the details contained herein are believed to be correct they do not form the basis of any contract and interested parties should contact the ompany to confirm whether any material alterations have been made since publication of this brochure. Issue 5.5 Setember 2014