Artificial Ventilation Theory into practice



Similar documents
Understanding Anesthetic Delivery Systems Dean Knoll, CVT, VTS (Anes.) Anesthesia Technician Supervisor University of Wisconsin Madison, WI May 2003

Oxygenation and Oxygen Therapy Michael Billow, D.O.

MECHINICAL VENTILATION S. Kache, MD

Pre-lab homework Lab 6: Respiration and Gas exchange

A COMPARISON OF THE COST OF INHALATIONAL ANAESTHESIA USING VARIOUS BREATHING SYSTEMS: IMPLICATIONS FOR THE DEVELOPNG WORLD

Common Ventilator Management Issues

GRADE 11F: Biology 3. UNIT 11FB.3 9 hours. Human gas exchange system and health. Resources. About this unit. Previous learning.

Keeping your lungs healthy

Principles of the Anesthetic Machine

The Anesthesia Ventilator

The Anesthesia Ventilator

Impact Uni-Vent 754 Portable Ventilator

Airway Pressure Release Ventilation

Airways Resistance and Airflow through the Tracheobronchial Tree

Veterinary Clinics and Hospitals

Ventilation Perfusion Relationships

The centrepiece of a complete anaesthesia workstation

2.06 Understand the functions and disorders of the respiratory system

Impact Uni-Vent 750 Portable Ventilator

PULMONARY PHYSIOLOGY

GUIDELINES FOR THE MANAGEMENT OF OXYGEN THERAPY

RESPIRATORY VENTILATION Page 1

MEDICAL SYSTEMS. Monnal T60. Touch and Breathe.

Tests. Pulmonary Functions

Volume Guarantee New Approaches in Volume Controlled Ventilation for Neonates. Jag Ahluwalia, Colin Morley, Hans Georg Wahle

Comparing Organs BIOLOGY SCIENCE INSTRUCTIONAL TASKS

Lab #11: Respiratory Physiology

How Organisms Exchange Gases: Simple Diffusion. How Organisms Exchange Gases: Simple Diffusion. How Organisms Exchange Gases: Respiratory Organs

Oxygenation. Chapter 21. Anatomy and Physiology of Breathing. Anatomy and Physiology of Breathing*

Auto Flow 20 Questions 20 Answers. Joseph Fitzgerald

Two Steps forward in Ventilation. Ernst Bahns. Because you care

Department of Surgery

GE Healthcare. Welcome to the future of anesthesia Aisys * Carestation *

A. All cells need oxygen and release carbon dioxide why?

Pulmonary Ventilation

2000 Respironics, Inc. All rights reserved.

reflect look out! organisms: living things

MECHANICAL VENTILATION IN THE NEONATE

Pediatric Respiratory System: Basic Anatomy & Physiology. Jihad Zahraa Pediatric Intensivist Head of PICU, King Fahad Medical City

Emphysema. Introduction Emphysema is a type of chronic obstructive pulmonary disease, or COPD. COPD affects about 64 million people worldwide.

DATA SHEET. Capnography option. November 2013 V2.2

Aliseo Anesthesia system

For every breath he takes. Trilogy200 ventilator s added sensitivity lets you breathe easier knowing your patients are where they belong home.

1. Our lungs are, essentially, a network of connected that bring

Your Lungs and COPD. Patient Education Pulmonary Rehabilitation. A guide to how your lungs work and how COPD affects your lungs

Aespire View. User s Reference Manual. Software Revision 6.X

Introduction to Animals

Trilogy200. Proximal pressure line. Exhalation valve line. Quick start guide. Overview. Circuit set-up. Set-up screen. Prescription set-up

Mechanical Ventilation for Dummies Keep It Simple Stupid

Ventilator Application of the Passy-Muir Valve David A. Muir Course Outline Benefits Review of the Biased Closed Position No Leak Passy-Muir Valves

Determinants of Fi,O 2 with oxygen supplementation during noninvasive two-level positive pressure ventilation

A Fishy Tale. Observing the Circulatory System of a Goldfish with a Compound Light Microscope

Physiology of Ventilation

Introduction to Cardiopulmonary Exercise Testing

LUNG VOLUMES AND CAPACITIES

Paul Clements, SpR in Anaesthetics, Hope Hospital, Salford, UK. Carl Gwinnutt, Consultant Anaesthetist, Hope Hospital, Salford, UK.

Caring for a Tenckhoff Catheter

Investigating the Human Body On-site student activities: Years 7-8 Investigating the Human Body On-site student activities Years 7 8

«The compact and mobile testing device for ventilators.»

INTRODUCING RESMED S. Home NIV Solutions. S9 VPAP ST-A with ivaps S9 VPAP ST. Why choose average when you can choose intelligent?

3100B Clinical Training Program. 3100B HFOV VIASYS Healthcare

Breathing and Holding Your Breath copyright, 2005, Dr. Ingrid Waldron and Jennifer Doherty, Department of Biology, University of Pennsylvania 1

CHAPTER 1: THE LUNGS AND RESPIRATORY SYSTEM

How To Treat A Patient With A Lung Condition

WHY IS BREATHING SO IMPORTANT?

Chapter 16: Circulation

Evaluation copy. Blood Pressure. Project PROJECT DESIGN REQUIREMENTS

Comparison of the Rate of Improvement in Gas Exchange between Two High Frequency Ventilators in a Newborn Piglet Lung Injury Model

NITROUS TRANSFER PUMP INSTRUCTIONS

Critical Care Therapy and Respiratory Care Section

Gas Exchange. Graphics are used with permission of: Pearson Education Inc., publishing as Benjamin Cummings (

Operator s Instruction Manual

Experiment HE-6: Breath by Breath Measurement of Respiratory Exchange Ratio (RER)

N26 Chest Tubes 5/9/2012

ONE-LUNG VENTILATION. Dr Lesley Strachan Consultant Anaesthetist Aberdeen Royal Infirmary. Self Assessment

Lab 4: Osmosis and Diffusion

MEDUMAT Easy CPR The Guiding Emergency Ventilator

Your personal anesthesia assistant DRÄGER PRIMUS

Oxygen & Aerosol Therapy

Aisys* CS 2 Advanced and Sustainable Anaesthesia Care NOT FOR USE IN THE UNITED STATES

Home Ventilator Breath of Life Home Medical Equipment and Respiratory Services

Fourth Grade The Human Body: The Respiratory System Assessment

Certain specific properties of compressed gases make them highly useful in various research activities.

Oxygen Therapy. Oxygen therapy quick guide V3 July 2012.

Oxygen - update April 2009 OXG

Things you might want to ask about asthma

Difficult Pre-hospital Airway Management

The Body s Transport System

The Take-Apart Human Body

AutoFlow The Oxylog 3000 plus incorporates the benefits of pressure controlled ventilation into volume controlled ventilation

OXYGEN THERAPY. DR :Gehan Ali. Lecturer of chest Ds Menoufia university

POLICIES & PROCEDURES. ID Number: 1115

Lesson 7: Respiratory and Skeletal Systems and Tuberculosis

Joanna Myers QAS 515 April 01, 2006 The Design of Scuba Diving Regulators & Breathing Resistance

Gas Exchange Graphics are used with permission of: adam.com ( Benjamin Cummings Publishing Co (

Human Body Vocabulary Words Week 1

VELA. ventilator user guide. Critical care ventilation

Understanding Hypoventilation and Its Treatment by Susan Agrawal

Boaray 700 Anesthesia Machine

Transcription:

Artificial Ventilation Theory into practice Keith Simpson BVSc MRCVS MIET(Electronics) www.vetronic.co.uk ksimpson@vetronic.co.uk June 13 th 2014 Today we will discuss the administration of IPPV to anaesthetised patients

Artificial Ventilation Theory into practice

Artificial Ventilation Theory into practice

IPPV Intermittent Positive Pressure Ventilation Positive pressure normal dynamics change Can be done in 2 ways By Hand By Mechanical Ventilator

IPPV by hand Consists of squeezing the bag and control of the exhaust valve (if there is one) Before we go too far we need to understand the circuit we are using before we give IPPV

Reservoir in Expiratory Circuit Typically seen with a T-piece or a Bain All gas flow is controlled by pressure Because of the circuit type, the FGF is typically quite high The FGF flushes out the waste gas Difficult to re-introduce waste gas

Reservoir in Expiratory Circuit When you occlude the bag it fills up with fresh gas Squeezing it forces fresh gas into the patient both from the bag/exp limb and incoming fresh gas When you release the bag the patient exhales and incoming FGF ensures it goes out of expiratory limb

IPPV with a T-Piece or Bain 1. Occlude the end of the reservoir bag (T-piece) or close the valve (Bain) 2. Allow gas to fill the bag 3. Squeeze the bag to inflate the chest 4. Release bag or open valve and allow patient to exhale 5. Repeat

Reservoir in Inspiratory Circuit Typically seen with a Magill or a Lack Gas flow is controlled by pressure and a one-way valve. Valve is always on the expiratory limb. Magill or Lack (Mini-Lack) circuit

Reservoir in Inspiratory Circuit Magill or Lack (Mini-Lack) circuit FGF is much less than T-piece circuit Circuit is efficient for spontaneous breathing but bad for IPPV

Manual ventilation with a Lack First time you squeeze the bag fresh gas forced in to animal.

Manual ventilation with a Lack Then when you release the bag, waste gas preferentially goes back into bag

Manual ventilation with a Lack Second time you squeeze the bag, you force waste gas back into patient. Very easy to cause rebreathing Cannot be repeated at speed without rebreathing

IPPV with a Magill After patient has exhaled, close the valve Let bag fill up with fresh gas Squeeze the bag to inflate the chest Maintain the pressure on the bag and open the valve the patient breathes out Close the valve and THEN release pressure on the bag Let the bag fill up with fresh gas.

IPPV with a circle system Circle system has its own valves If you close the exit valve it is a closed system Squeezing the bag forces fresh gas (no CO2) into the patient. Releasing the bag allows waste gas to go to circle Can give IPPV several times before opening valve, squeezing bag and re-filling with fresh oxygen

Manual IPPV summary Much safer with a bag in the expiratory circuit such as a T-piece or Bain. Can perform faster IPPV When using a Lack/Magill make sure you allow exhaled gas to leave before releasing the bag If you are using a circle then one-way-valves ensure that rebreathing cannot occur. Close the waste valve to give IPPV. Replenish oxygen every 10 breaths

Dangers of IPPV Really only 2 problems: Over-inflation Under-inflation

Dangers of IPPV Over-inflation In mammals safety is conferred by a diaphragm which seals the chest cavity limiting expansion Therefore care needed in birds and reptiles and all non-mammals In mammals Volutrauma/Barotrauma does not occur below 30cm pressure

Dangers of IPPV Without a diaphragm there is less to limit expansion of lung tissue, so over distension can occur. The only measure we have as a guide to safety is to monitor the airway pressure. In non-mammals ventilation pressures of over 15 cm H20 are rarely required

Dangers of IPPV When giving manual IPPV how can you be sure that you are not exceeding 15cm pressure? This is very difficult to achieve It is also difficult to be consistent

Dangers of IPPV Demonstration of hand ventilation pressures using a T-piece circuit and an open-ended bag

Dangers of IPPV Under-inflation Failure to deliver anaesthetic agent patient wakes up Failure to remove CO2 - patient becomes hypercapnic Failure to deliver oxygen patient becomes hypoxaemic

IPPV What are the aims of IPPV? Maintain anaesthesia by delivery of gaseous anaesthetic Deliver Oxygen to the patient Remove Carbon Dioxide from the patient

Dead Space What is dead space? The volume in the common gas circuit that does not contribute to gas exchange The common gas circuit is the area where both inspired and expired gases pass (two-way flow).

Dead Space Why is it a problem? Patient is always rebreathing the last portion of gas it breathed out which is rich in CO2

Dead Space No matter how you change the FGF, or the circuit the patient is attached to, you cannot influence the size of the dead space

Dead Space More of a problem with our smaller patients Wish to keep dead space as small as possible but at least less than 10% of tidal volume

Dead Space Won t the capnograph alert you to this problem? ONLY if you re sampling in the common gas region, NOT if you re sampling at the Y- piece Do not sample from here Sample from this region

Mechanical IPPV Now we know all about manual IPPV we can look at mechanical IPPV and why it can help We will be looking at pressure-cycled ventilators with particular reference to the SAV03

SAV03/SAV04

SAV03 How does it work? Very simple. It is best described as a mechanical thumb.

SAV03 Ventilator By Hand 1. Close off bag outlet 2. Squeeze bag to inflate chest 3. Rate of chest inflation depends on how fast you squeeze 4. Extent of chest inflation depends on how much you squeeze the bag 5. At target volume you stop squeezing and release the outlet to allow patient to breathe out =Volume Cycling SAV03 1. Solenoid closes 2. Incoming gas inflates chest 3. Rate of chest inflation depends on Fresh Gas Flow rate 4. Extent of chest inflation depends on target pressure 5. At target pressure solenoid releases and patient breathes out =Pressure Cycling

SAV03 Ventilator When ventilating by hand you are essentially volume cycling. Giving an amount of gas until the chest expansion looks about right. There is no accurate appreciation of pressure When using the SAV03 you are pressure cycling. Giving an amount of gas until the chest expansion results in a certain pressure. There is no accurate appreciation of volume given

SAV03 Ventilator Generally, it is pressure that will lead to lung damage The pressure set by the machine is worst case. There is nearly always a pressure drop along the length of the tube so the lungs see less pressure than is measured at the end of the ET tube.

SAV03 Operation When the valve is closed the fresh gas (blue) can only go down the ET tube to the patient. This is inspiratory phase

SAV03 Operation When the valve is open the waste gas (red) can only go out of the exhaust port because of the pressure from the FGF. This is expiratory phase

SAV03 Operation When the valve closes again the waste circuit is completely cut off so it does not matter what you do in the waste gas circuit when the patient is being ventilated Notice the dead space area below in red

SAV03 Operation If that dead space area is more than 10% of your patient s tidal volume then you may need to use the Low Dead Space kit. The actual volume of that area when using a LDS ET connector is around 0.5mls, so your smallest patient should be around 400g Check it using a capnograph

Primary aims of ventilation Keep animal asleep Deliver oxygen/agent into the patient's chest to inflate it to a level consistent with normal oxygen exchange Ensure adequate removal of CO2 with little or no expiratory resistance Sounds easy. So where are the problems?

Ventilating a patient How much do you inflate? How fast do you inflate? What is too much? What happens when you give too much?

Ventilating a patient The answers to all of the above relate to pressure. It is pressure that regulates the efficiency of gas exchange. It is pressure that can potentially cause some harm So how much is enough and how much is too much?

How much do you inflate? Target pressures Mouse : 6-7cm H 2 0 weight 30g Horse : 20cm H 2 0 weight 500kg Target ventilation pressures are not related to weight. Cannot weigh an animal, look at a chart and determine the ventilation pressure required. But! You can safely assume that any animal will fall in the range of 6-20cm H 2 0

How much do you inflate? So start low and increase your target pressure to obtain normal chest movements and if possible normo-capnia You will need a snug fitting ET tube for ventilation

How fast do you inflate? Remember the inflation rate is controlled by the FGF rate from the machine Keep it as close to 3 x Minute Volume as possible. Under 3 x MV and will have excessive Insp Time Over 3 x MV and may lose pressure along the tube much worse with very small patients MV = Resp Rate x Tidal Volume It is better to err on the side of a lower flow rate than a high one will get better oxygen delivery at slower inflation rates

How fast do you inflate? Example 500g Patient TV = 6 mls (12mls/kg) RR = 30 bpm MV = TV x RR = 180mls/minute 3 x MV = 540mls/minute Set FGF to 0.4-0.5L/Min.

What is too much? Human studies would suggest that 30cm is the upper safe limit for mammals because Ventilator Induced Lung Trauma is not seen at levels below this. Mammals have a restraining chest wall & diaphragm. Other species do not. In those other species, pressures less than 30 cm may cause shearing/tearing of lung tissue, but there is rarely any need to exceed 15cm pressure.

What is too much? - Birds Birds have a unique one-way flow pattern of air through their lungs. Not known if this pattern is fully maintained in birds during IPPV Their through-flow system means that flow is much more important than pressure So keep pressure low (<15) and RR high (at least at normal Resp Rates)

What is too much? - reptiles Have a more mammalian-like lung structure But no restraining diaphragm Two-way flow pattern, so good alveolar distension is important At risk of shear-damage if over-distend Try to keep pressures < 15 cm H 2 O and do not exceed 20 cm H 2 O

What is too much? - Mammals With a closed chest pressures of up to 60cm can be tolerated in large animals such as the horse. In normal practice however, it is unusual to need to ventilate at target pressures of more than 25 cm H 2 O Most patients adequately ventilated at 10-15 cm H 2 O

What happens when you give too much? There may be no obvious outward signs initially Over-distension & shear damage in the lungs can lead to an inflammatory response that will produce an interstitial oedema Over time this inflammatory response will reduce lung function and it may appear that the patient needs more ventilation resist the urge to increase the TV by increasing the Target Pressure. In birds, air sacs may rupture, particularly if diseased. Unless this results in a leak of gas (i.e. into the room), air flow through the lungs is likely to remain sufficient

Ventilating a patient Now we know the theory behind performing IPPV, we can ventilate a patient

Ventilating a patient 1. Induce and intubate your patient using the best-fitting tube that you can for minimal loss of gas around the tube 2. Connect to your circuit and start IPPV 3. Control can be accomplished in nearly all animals by initially over-ventilating 4. Use a short expiratory time and a slightly higher than normal Target Pressure.

Ventilating a patient Example: Bird with a normal RR of 40 breaths per minute. Aim for a ventilation rate of 50 breaths per minute to overcome the respiratory drive Use a peak pressure of 10-12 cm H2O to deliver big breaths until the bird is clearly under ventilator control and then return it to 8-9. Keep the ventilation rate at around 40 and if at all possible monitor with a capnograph to assess expired CO2 levels. Adjust the peak pressure to give normal chest movements

Ventilating a patient How to respond Patient becomes light Increase frequency of ventilation to increase Minute Volume - Increase Target Pressure by 2cm H20 to increase Minute Volume - Change anaesthetic concentration

Ventilating a patient How to respond Rising end-tidal CO2 - Increase frequency of ventilation to increase Minute Volume - Increase Target Pressure by 2cm H20 to increase Minute Volume

Ventilating a patient Stopping Ventilation/Weaning off Have spent all the time suppressing spontaneous respiratory drive Now need to re-establish respiratory drive Reduce feedback by stretch receptors - reduce Target Pressure by 2cm H2O Increase resp drive by increasing CO2 - reduce resp rate

Ventilation Discussion

Ventilation Summary When using manual ventilation be aware of the circuit configuration you are using When using mechanical ventilation be aware of the pressures being delivered Well-controlled IPPV is a life-saver