W 36: Mastering complex tasks reliably



Similar documents
intelligent solutions

W150: Miniature photoelectric switch series with completely integrated electronics

W 160: Miniature series for optimum solutions

LUT Luminescence scanners: Seeing what no-one else can

W 2: Subminiature photoelectric switch series: extremely small and extremely strong

Photoelectric switches WLL 170(T), fibre-optic cables LL 3: flexible solutions with fibre-optic cable systems

V180-2 M18 Cylindrical Photoelectric Sensor Series

ONLINE DATA SHEET WT34-R220 W34 PRODUCT PORTFOLIO

sensors Miniature Sensors - S100 The universal miniature photoelectric sensor

Photoelectric sensors V180-2, Photoelectric retro-reflective sensor, Standard optics

Universal Voltage Terminal Photoelectric E3JM

Color Mark Sensor with Red or Green LED E3S-VS

Dimensional drawing. Connection type IME08-1B5NOZT0S IME08-1B5NSZT0S IME08-1B5POZT0S IME08-1B5PSZT0S. 3 x 0.14 mm². brn. L+ Schließer/ Öffner M.

PD30ETB20xxIS. Photoelectrics, Background Suppression reflective with IR light. Main features. Description

SENSORS. Miniature Sensors - S3Z. Advanced line of miniature Asian style of photoelectric sensors mm background suppression

For accurate positioning in warehouse and conveying areas

Laser diffuse reflection light scanner with background suppression. Dimensioned drawing

Thru-Beam 80 to 320 mm 0.05 to 0.08 mm

photoelectric highlights

Throughbeam photoelectric sensors. Dimensioned drawing. Electrical connection

Compact Sensors - S8 Series. Compact size and high performance for the most challenging detection applications

OPERATING PRINCIPLES FOR PHOTOELECTRIC SENSORS

Clear Glass Sensor. Ordering Information E3S-CR67/62. Optimum Sensor for Detecting Transparent Glass and Plastic Bottles

Speed Control Relays SX2

technical data (according to IEC )

Power Supply and Indicator Unit Type Fig. 1 Type Mounting and Operating Instructions EB 9539 EN

E3Z. Ordering Information. Photoelectric Sensor with Built-in Amplifier. Compact Sensor Offers Long Sensing Distance and Superior Noise-Immunity

Tubular Analog model resolution: 0,5 mm (SLOW mode), 1 mm (FAST mode) Right angle Repeatibility: 0,7 mm Vdc

BOS 73K... BOS 74K...

Overview. Application Areas. DMP Position Finder

Inductive sensor NI10-M18-Y1X-H1141

Long sensing range. Most suitable for conveyor lines and parking lot applications. 10 m ft (Red LED)

Sensing method Appearance a Connection o method Sensing distance Model NPN output PNP output Through-beam Pre-wired (see note 3) Connector.

Cross-beam scanning system to detect slim objects. 100 mm in

Capacitive Prox E2K-X

Inductive Proximity Sensors

NIVOCONT CONDUCTIVE LEVEL SWITCHES LEVEL SWITCHES

How To Control A Power Supply With A Mini Transmitter And Switch (Power Supply)

SSC-T800series. New type with radial cross ray method. Light Curtain Sensors. Type. Radial Cross Ray Method. Detecting width. Light axis interval

HERZ-Thermal Actuators

ONLINE DATA SHEET. Contrast sensors KTM KTM-WP11181P

ACS-30-EU-EMDR-10-MOD

VIBRATION MONITORING OF FANS INSTALLED IN ROAD TUNNELS

Proximity Sensors Inductive Thermoplastic Polyester Housing Types EI, DC, M 12, M 18, M 30

97300 NAMUR series, 3/2 & 5/2 Indirect solenoid actuated spool valve

fiber-optic sensors WLL180T, Fiber-optic photoelectric sensor

(68.52) X. June 2000 Supercedes February xenex CONVENTIONAL FIRE DETECTION & ALARM SYSTEM. we business differently

Laserlyte-Flex Alignment System

Turbine Flow Sensor Series VTR

Industrial infrared heater IR For premises with large volumes and high ceilings

Color sensors CS8, CS8-1

FIRE ALARM SYSTEM TECHNICAL SPECIFICATIONS Page 1 of 10

Type: EASY719 DC RC Article No.: Ordering information Relay outputs Quantity 6 Power supply V DC 24 V DC. Description

LED control gear. LED control gear

Duct Humidity Transmitter

Electrical connection

Sturdy aluminium housing, anodized in blue Female connector for optical fiber (please order optical fiber separately) Mounting holes

Ferrostat Speed Sensor Series DSF Explosion Proof Versions EEx

Specifications H8CA-S H8CA-S RATINGS. Approved by the following standards CHARACTERISTICS

D ATA S H E E T. DT50 Laser class 1. Laser distance sensor

Magnetic and Hydraulic-Magnetic Circuit Breaker 8340-G2...

Givare NC-SRS 280 och 880

E2EL Ø 6,5 M8 / Plug M8 M8 / Plug M12 E2EL

Operating instructions Diffuse reflection sensor with background suppression O1D101 O1D / / 2012

E3T Miniature Photoelectric Sensors

Control Devices Catalogue. Control Devices. Preferred and Standard Products

2/ These vacuum switches are used in measuring ranges between -1 and 0 bar.

Automation System TROVIS 6400 TROVIS 6493 Compact Controller

EE-SX91. Meeting Customer Needs with Compact Sensors that Mount with M3 Screws

MAIN CATALOGUE MAKING SENSE OF TECHNOLOGY

80 Series - Modular timers 16 A. Features

ABB i-bus KNX Fan Coil Actuator, MDRC FCA/S 1.1M, 2CDG R0011

Inductive Sensors Single or Dual Loop Detectors Type LD with teach-in

Heating, air-conditioning, cooling

38 SERIES. Relay interface modules A. EMR Electromechanical Relays. Common features. SSR Solid State Relays. 6.

Technical data. General specifications. Indicators/operating means. 30 Hz Multiplex operation 30 Hz / n, n = number of sensors, n 5

Fiber-Optic Photoelectric Sensor

Electronic Pressure Switch EDS 300

Multifunction devices

Miniature High-Resolution Registration Mark Sensor White LED AUTOSET Remote Setup Option

WINGLIKE ELECTRONICS CO.,LTD

IR Receiver Module for Light Barrier Systems

New XUY roller sensors

SENSORS. Fiber Optic Sensors - S70. Advanced fiber optic amplifiers for high speed and low contrast applications

Linear Luminaire for Fluorescent Lamps Series EXLUX 6001

How To Read A Pipe From A Sensor

Digital Pressure Measuring Instrument MDR480

Adjustment functions for both span and shift have been incorporated

L-LAS-TB-CL serie. laser light curtains for inline measuring tasks

Control- and feedback head for integrated mounting on Robolux valves Type 2036

Temperature sensor with integrated transmitter for industrial applications, MBT 3560

RoHS. Shock / vibration resistant. Magnetic field proof. Many variants

Process modules Digital input PMI for 24 V DC inputs for 120 V AC inputs

TECHNICAL DATASHEET Incremental Encoder RI 58-H

Electronic pressure switch with display Model PSD-30, standard version Model PSD-31, with flush diaphragm

Transcription:

Lichtschranken W Photoelectric Baureihe switches WL - Photoelectric proximity switches, BGS Photoelectric reflex switches W : astering complex tasks reliably Through-beam photoelectric switches for temperatures ranging from to + C and polarising filters also make it possible to detect shiny surfaces. The scanning ranges of the W series speak for themselves: metres for the WS/WE through-beam photoelectric switch, metres for the WL photoelectric reflex switch and mm for the WT photoelectric proximity switch, which also offers adjustable scanning distance and background suppression. Great demands are often placed on the mechanical endurance of sensors. Suitable enclosure ratings (depending on the type of connection) of IP and IP, robust plastic housings, prefailure signalling output and indi- UUsers have long appreciated the benefits of the W series of photoelectric switches. Thanks to their design, the devices can be used both indoors and outdoors, since all DC types are suitable cator, and insensitivity to ambient light ensure reliable switching in hostile industrial environments. Universal voltage versions, time delay, test input and selectable light- or dark-switching are additional characteristic features of the W series. SENSICK CATALOGUE

W m aking sure that crates are full: WL photoelectric reflex switches used to count coloured bottles before packaging. m WL photoelectric reflex switches checking the presence of beer crates before automatic removal of the bottle caps. v WL sensors used to detect mesh baskets in front of a goods lift. n Hot or cold, wet, dry or dusty WL photoelectric reflex switches are designed for use under hostile operating conditions indoors and outdoors here they are being used on the roll-up gate of a carwash. SENSICK CATALOGUE

WT Photoelectric proximity switches, infrared light -- DC/UC, plug connection Scanning distance... mm Dimensional drawing Photoelectric proximity switches Robust plastic housing Infrared light Selectable time delay ø. max. Adjustments possible WT -N WT -R WT -P WT -N WT -P.-. s Rel. off t t t t t t t t t t t t t t.- s Rel. on.-s Distance Distance X Standard direction of the material being scanned Alignment sight Centre of optical axis, receiver Centre of optical axis, sender LED signal strength indicator threaded mounting hole. mm deep ounting holes, recesses on both sides for hex nuts Time delay selector switch with DC, time delay and light-/dark-switching selector switches with UC Light-switching Dark-switching Time control Scanning distance adjustment C V Switch-selectable time delay.. s with DC only. s with DC. s with UC t without time delay t without time delay t without time delay t ON-delay t ON-delay t ON-delay t OFF-delay t OFF-delay t OFF-delay WT -N WT -N WT -R WT -P WT - P Accessories page Cable receptacles ounting brackets SENSICK CATALOGUE -pin, -pin -pin L+ L+ Q Q Q Q TE L N

WT Technical data WT - N P N P R Scanning distance... mm, adjustable Light source ), light type Light spot diameter LED, infrared light Approx. mm at mm Supply voltage V S... VDC )... V UC (+ % / %) Ripple ) V SS Current consumption ) ma Power consumption < VA Switching outputs PNP, Q and Q NPN, Q and Q SPDT, isolated ) Output current I A max. ma ax. switching voltage AC: V / DC: V Switching current A / V AC or V DC ax. switching capacity AC: VA / DC: W Response time ) ms ms ax. switching frequency ) /s /s Test input TE, sender OFF PNP: Test input to V NPN: Test input to V S VDE protection class ) Circuit protection ) Plug V A, B, C A, C Enclosure rating IP IP Ambient temperature T A Operation C...+ C Operation C...+ C Storage C...+ C Weight Approx. g Housing material Glass-fibre-reinforced plastic ) Average service life, h at T A = + C ) Limit values ) ay not exceed or fall short of V S tolerances ) Without load ) Provide suitable spark suppression for inductive or capacitive loads ) Signal transit time with resistive load ) With light/dark ratio : ) Reference voltage V DC, V AC ) A = V S connections reverse-polarity B = Output Q N and Q P short-circuit C = Interference pulse suppression Scanning distance (mm) Scanning distance on black, % remission Scanning distance on grey, % remission %/% Order information Type WT -N WT -P WT -N WT -P WT -R Part no. % of scanning distance %/% (mm) SENSICK CATALOGUE

WT Photoelectric proximity switches, infrared light -- DC/UC, terminal connection Scanning distance... mm Dimensional drawing Photoelectric proximity switches Robust plastic housing Infrared Adjustable background suppression Easily accessible terminal chamber Selectable time delay ø. Adjustments possible WT -N WT -R WT -P.-.s t t t t t t.-s t Distance Rel. off t t t t t t Rel. on.-s t Distance X Standard direction of the material being scanned Alignment sight Centre of optical axis, receiver Centre of optical axis, sender LED signal strength indicator threaded mounting hole. mm deep ounting holes, recesses on both sides for hex nuts Time delay selector switch with DC, time delay and light-/dark-switching selector switches with UC Light-switching Dark-switching Time control Scanning distance adjustment Terminal connection C V Switch-selectable time delay.. s with DC only. s with DC. s with UC t without time delay t without time delay t without time delay t ON-delay t ON-delay t ON-delay t OFF-delay t OFF-delay t OFF-delay WT -N WT -R WT -P Accessories page ounting brackets PG, terminals L+ Q Q TE PG, terminals L N SENSICK CATALOGUE

WL - WT Technical data WT - N P R Scanning distance... mm, adjustable Light source ), light type Light spot diameter LED, infrared light Approx. mm at mm Supply voltage V S... VDC )... V UC (+ % / %) Ripple ) V SS Current consumption ) ma Power consumption < VA Switching outputs PNP, Q and Q NPN, Q and Q SPDT, isolated ) Output current I A max. ma ax. switching voltage AC: V / DC: V Switching current A / V AC or V DC ax. switching capacity AC: VA / DC: W Response time ) ms ms ax. switching frequency ) /s /s Test input TE, sender OFF PNP: Test input to V NPN: Test input to V S VDE protection class ) Circuit protection ) Terminal connection V A, B, C A, C Enclosure rating IP Ambient temperature T A Operation C...+ C Operation C...+ C Storage C...+ C Weight Approx. g Housing material Glass-fibre-reinforced plastic ) Average service life, h at T A = + C ) Limit values ) ay not exceed or fall short of V S tolerances ) Without load ) Provide suitable spark suppression for inductive or capacitive loads ) Signal transit time with resistive load ) With light/dark ratio : ) Reference voltage V DC, V AC ) A = V S connections reverse-polarity B = Output Q N and Q P short-circuit C = Interference pulse suppression Scanning distance (mm) %/% Order information Type WT -N WT -P WT -R Part no. Scanning distance on black, % remission Scanning distance on grey, % remission % of scanning distance %/% (mm) SENSICK CATALOGUE

WL Photoelectric reflex switches, red light -- DC Scanning range m Dimensional drawing Photoelectric reflex switches Robust plastic housing Visible red light Selectable time delay ø. max. Adjustments possible WL -B WL -B WL -B WL -B t a b Alignment sight Centre of optical axis, receiver Centre of optical axis, sender LED signal strength indicator threaded mounting hole. mm deep ounting holes recesses on both sides for hex nuts ON/OFF timer switch t = Time ON, = Time OFF Time delay ON-delay OFF-delay Time control. to s Light/dark selector a = Light-switching, b = Dark-switching Sensitivity adjustment Terminal connections C V WL -B WL -B WL -B WL -B Accessories page Cable receptacles ounting brackets Reflectors Attachable heated cover PG, terminals -pin, -pin -pin L+ L+ L+ Alarm Q P Alarm QP Alarm Q P Q N Q N TE TE L+ (Alarm) QP (Q N ) SENSICK CATALOGUE

WL - WL Technical data WL - B B B B Scanning range, max. typ./on reflector m /PL A Sensitivity Adjustable Light source ), light type LED, red light Light spot diameter Approx. mm at m Supply voltage V S... VDC ) Ripple ) V SS Current consumption ) ma Switching outputs PNP: Q P and NPN Q N PNP: Q P PNP: Q P or NPN Q N Light-/dark-switching Switch-selectable Output current I A max. ma Response time ). ms ax. switching frequency ) /s Pre-failure signalling output Alarm, PNP, open collector Internal resistance. kω ± % Operating condition correct ) Output HIGH (V S. V) Operating condition faulty Switching periodically at /s to V S Test input TE Sender switched off Sender OFF Test input to V Connection type PG cable gland VDE protection class ) Circuit protection ) Plug V A, B, C Enclosure rating IP IP Ambient temperature T A Operation C...+ C Storage C...+ C Weight Approx. g Polarising filter Housing material Glass-fibre-reinforced plastic ) Average service life, h at T A =+ C ) Limit values ) ay not exceed or fall short of V S tolerances ) Without load ) Signal transit time with resistive load ) With light/dark ratio : ) Signal reserve % ) Reference voltage V DC ) A = V S connections reverse-polarity B = Output Q N and Q P short-circuit C = Interference pulse suppression Operating range and operating reserve....... (m) Reflector type PL A C Operating range PL A PL A PL A PL A Reflective tape «Diamond Grade»...m Operating range...m...m...m...m... m... m Scanning range, max. typical Operating reserve Operating range Scanning range, max. typical (m) Order information Type Part no. WL -B WL -B WL -B WL -B SENSICK CATALOGUE

WL Photoelectric reflex switches, red light -- UC Scanning range m Dimensional drawing Photoelectric reflex switches Robust plastic housing Visible red light Easily accessible terminal chamber Selectable time delay ø. max. Adjustments possible WL -R WL -R t a b Alignment sight Centre of optical axis, receiver Centre of optical axis, sender LED signal strength indicator threaded mounting hole. mm deep ounting holes recesses on both sides for hex nuts ON/OFF timer switch t = Time ON, = Time OFF Time delay ON-delay OFF-delay Time control. to s Light/dark selector a = Light-switching, b = Dark-switching Sensitivity adjustment Terminal connections C V WL -R WL -R Accessories page Cable receptacles ounting brackets Reflectors Attachable heated cover PG, terminals L N -pin L N SENSICK CATALOGUE

WL - WL Technical data WL - R R Scanning range, max. typ./on reflector m /PL A Sensitivity Adjustable Light source ), light type Light spot diameter LED, red light Approx. mm at m Supply voltage V S... V UC (+ %/ %) Power consumption < VA Switching output SPDT, isolated ) ax. switching voltage AC: V / DC: V ax. switching current A / V AC or V DC ax. switching capacity AC: VA / DC: W Response time ms ax. switching frequency ) /s Light-/dark-switching Switch-selectable PG cable gland Plug VDE protection class ) Circuit protection ) V A, C Enclosure rating IP IP Ambient temperature T A Operation C...+ C Storage C...+ C Weight Approx. g Polarising filter Housing material Glass-fibre-reinforced plastic ) Average service life, h at T A = + C ) Provide suitable spark suppression for inductive or capacitive loads ) With light/dark ratio : ) Reference voltage V AC ) A = V S connections reverse-polarity C = Interference pulse suppression Operating range and operating reserve....... (m) Reflector type PL A C Operating range PL A PL A PL A PL A Reflective tape «Diamond Grade»...m Operating range...m...m...m...m... m... m Scanning range, max. typical Operating reserve Operating range Scanning range, max. typical (m) Order information Type Part no. WL -R WL -R SENSICK CATALOGUE

WS/WE Through-beam photoelectric switches, infrared light -- DC Scanning range m Dimensional drawing Through-beam photoelectric switches Robust plastic housing Infrared light Selectable time delay ø. max. Adjustments possible WS/WE -B WS/WE -B WS/WE -B t a b Alignment sight Centre of optical axis, receiver Centre of optical axis, sender LED signal strength indicator, top and front threaded mounting hole. mm deep ounting holes recesses on both sides for hex nuts ON/OFF timer switch t = Time ON, = Time OFF Time delay ON-delay OFF-delay Time control. to s Light/dark selector a = Light-switching, b = Dark-switching Sensitivity adjustment Terminal connections C V WS/WE -B WS/WE -B WS/WE -B PG, terminals -pin, -pin Accessories page Cable receptacles ounting brackets Attachable heated cover Sender L+ TE L+ TE L+ TE Receiver L+ Alarm Q P Q N L+ Alarm QP L+ Alarm Q P Q N TE SENSICK CATALOGUE

WL - WS/WE Technical data WS/WE - B B B Scanning range, max. typical Sensitivity m Adjustable Light source ), light type Light spot diameter LED, infrared light Approx. mm at m Supply voltage V S... VDC ) Ripple ) V SS Current consumption ) ma Switching outputs PNP: Q P and NPN Q N PNP: Q P Light-/dark-switching Switch-selectable Output current I A max. ma Response time ). ms ax. switching frequency ) /s Pre-failure signalling output Alarm, PNP, open collector Internal resistance. kω ± % Operating condition correct ) Output HIGH (V S. V) Operating condition faulty Switching periodically at /s to V S Test input TE Sender switched off Sender OFF Test input to V PG cable gland VDE protection class ) Circuit protection ) Plug V A, B, C Enclosure rating IP IP Ambient temperature T A Operation C...+ C Storage C...+ C Weight Approx. g Housing material Glass-fibre-reinforced plastic ) Average service life, h at T A =+ C ) Limit values ) ay not exceed or fall short of V S tolerances ) Without load ) Signal transit time with resistive load ) With light/dark ratio : ) Signal reserve % ) Reference voltage V DC ) A = V S connections reverse-polarity B = Output Q N and Q P short-circuit C = Interference pulse suppression Operating range and operating reserve Order information Type WS/WE -B WS/WE -B WS/WE -B Part no. (m) Operating range Scanning range, max. typical Operating reserve Operating range Scanning range, max. typical (m) SENSICK CATALOGUE

WS/WE Through-beam photoelectric switches, infrared light -- UC Scanning range m Dimensional drawing Through-beam photoelectric switches Robust plastic housing Infrared light Easily accessible terminal chamber Selectable time delay ø. max. Adjustments possible WS/WE -R WS/WE -R t a b Alignment sight Centre of optical axis, receiver Centre of optical axis, sender LED signal strength indicator, top and front threaded mounting hole. mm deep ounting holes recesses on both sides for hex nuts ON/OFF timer switch t = Time ON, = Time OFF Time delay ON-delay OFF-delay Time control. to s Light/dark selector a = Light-switching, b = Dark-switching Sensitivity adjustment Terminal connections C V WS/WE -R WS/WE -R PG, terminals -pin Accessories page Cable receptacles ounting brackets Attachable heated cover Sender L N L N Receiver L N L N SENSICK CATALOGUE

WL - WS/WE Technical data WS/WE - R R Scanning range, max. typ./on reflector m Sensitivity Adjustable Light source ), light type Light spot diameter LED, infrared light Approx. mm at m Supply voltage V S... V UC (+ %/ %) Power consumption < VA Switching output SPDT, isolated ) ax. switching voltage AC: V / DC: V ax. switching current A / V AC or V DC ax. switching capacity AC: VA / DC: W Response time ms ax. switching frequency ) /s Light-/dark-switching Switch-selectable PG cable gland Plug VDE protection class ) Circuit protection ) V A, C Enclosure rating IP IP Ambient temperature T A Operation C...+ C Storage C...+ C Weight Approx. g Housing material Glass-fibre-reinforced plastic ) Average service life, h at T A = + C ) Provide suitable spark suppression for inductive or capacitive loads ) With light/dark ratio : ) Reference voltage V AC ) A = V S connections reverse-polarity C = Interference pulse suppression Operating range and operating reserve Order information Type WS/WE -R WS/WE -R Part no. (m) Operating range Scanning range, max. typical Operating reserve Operating range Scanning range, max. typical (m) SENSICK CATALOGUE