INSTRUCTION MANUAL Oil level indicator with pointer



Similar documents
OLI. Oil level indicator

LEVEL GAUGES WITH MAGNETIC JOINT L 14 - L 22 - L 34

PPS-PPQ-BT-PIAS RESIN INSULATORS FOR OIL INSULATED ELECTRICAL MACHINES

HEAT MONITORING AND CONTROL INSTRUMENTS FOR TRANSFORMERS MB 103 TEMPERATURE CONTROL UNIT PT 100 TEMPERATURE SENSOR

WE-350 Series ¼ Turn Electric Actuator

Elektromotoren und Gerätebau Barleben GmbH

Outdoor 33.6W Dual Port Passive Power-over-Ethernet Midspan For External Security Cameras and Wireless Access Points

Pressure monitoring equipment for oil-sf 6. bushings, type GOEK

* DISCLAIMER: Contents. How to Use This Guide: COMMERCIAL INSTALL GUIDE 2

Elektromotoren und Gerätebau Barleben GmbH

Cross-beam scanning system to detect slim objects. 100 mm in

Series 6000 Torque measured metal bellow coupling

OPL BASIC. Dosing System for Professional Laundry machines. Contents

33.6W Power over Ethernet Waterproof Adapter PoE Plus Single Port Injector for Outdoor Application

I nstallation. M100Q Series Proportional Actuator with R81Q Controller Board for Thermistor Sensor Applications. Tools Needed.

EX-TECH SAS CP/PB 150 EXPLOSIONPROOF MANUAL CALL POINT/ PUSH BOTTON TECHNICAL MANUAL

Contactless Encoder RI360P0-QR24M0-INCRX2-H1181

Technical data. General specifications. Signal voltage V DC Signal duration. 1 s Input 2. Signal voltage. 1 s Analog output.

Floating Switch FTS 20 Füllstandgrenzschalter Level Limit Switch Détecteur de niveau

Description. Dimensions. Features. precision works better

Modular I/O System Analog and Digital Interface Modules

GREISINGER electronic GmbH

HMI display Installation Guide

Ferrostat Speed Sensor Series DSF Explosion Proof Versions EEx

Adjustment functions for both span and shift have been incorporated

TM7BDM8B expansion block - TM7 - IP67-8 DI/DO - 24V DC A - M8 connector

Duct Humidity Transmitter

Magnetic and Hydraulic-Magnetic Circuit Breaker 8340-G2...

Contents. Document information

Mounting Instructions. Torque Transducer. A en

CONNECTOR AMPLIFIER FOR PROPORTIONAL VALVES (4-20 ma Input Version)

Arecont Vision H.264 Color or Day/Night SurroundVideo Series Installation Manual

Series 7500 Torque Sensor

Radiant Temperature Sensor TY7321

ABB Drives. User s Manual. Pulse Encoder Interface Module RTAC-01

Tubular Analog model resolution: 0,5 mm (SLOW mode), 1 mm (FAST mode) Right angle Repeatibility: 0,7 mm Vdc

PSDC PSDC 12V/8A/8x1A Power supply for up to 8 analog cameras PTC/TOPIC.

SENSORS. Miniature Sensors - S3Z. Advanced line of miniature Asian style of photoelectric sensors mm background suppression

ZC-24DO CANopen I/O Module: 24 Digital Outputs

Capacitive Prox E2K-X

T7560A,B,C Digital Wall Module

INSTALLATION AND OPERATING INSTRUCTIONS For Model GL1 Gate Locks

Manual for Fire Suppression & Methane Detection System

MCR1900 Media Converter 19-Slot Chassis

LUCCI AIRFUSION QUEST II CEILING FAN

R O A D M A S T E R, I N C.

Toroidal Conductivity Sensor

RoHS. Shock / vibration resistant. Magnetic field proof. Many variants

Fire Pump Applications

How To Use A Ds340 (Dsp)

Instruction Manual Differential Pressure Transmitter

Technical Data Sheet. 3DLevelScanner

Electric Rotary Actuator - On/Off or programmable control actuator

Reaction Torque Sensor

ORTHOBLOC Drive systems. Installation. This manual is to be given to the end user en / k. R max - 5 mm.

CAUTION OPC-LM1-IL. Option Card for Encoder of Line Driver Output. Instruction Manual

R O A D M A S T E R, I N C.

USER S GUIDE. EE210 - Humidity and Temperature Transmitter for demanding Climate Control Applications GENERAL CAUTION CONNECTION DIAGRAM

97300 NAMUR series, 3/2 & 5/2 Indirect solenoid actuated spool valve

SSC-T800series. New type with radial cross ray method. Light Curtain Sensors. Type. Radial Cross Ray Method. Detecting width. Light axis interval

TX OPEN RS232/485 module

PD30ETB20xxIS. Photoelectrics, Background Suppression reflective with IR light. Main features. Description

Digital input modules

Mounting instructions. Junction box VKK2R-8 DIGITAL. A en

Antenna Splitter ASA 1. Instruction manual

Ordering Information. Cylindrical Proximity Sensor E2E/E2E2

3DLevelScanner II TECHNICAL DATA SHEET

AXIS T81B22 DC 30W Midspan

ATL Fuel Level Sender Probes

R O A D M A S T E R, I N C.

WaterMAG. Electromagnetic Flowmeter for Water Applications. Model MCB10A OVERVIEW APPLICATIONS FEATURES. No. SS2-MCB

Output torques up to 8000 Nm. General features. Protection. External coating. Working temperature range

When any of the following symbols appear, read the associated information carefully. Symbol Meaning Description

Machine Safety Switches

Operation Manual For NDJ-8S Digital Rotary Viscometer

SENSORS. Fiber Optic Sensors - S70. Advanced fiber optic amplifiers for high speed and low contrast applications

Inductive sensor NI10-M18-Y1X-H1141

Day / Night IR Color Camera User Manual V2.1.0

FN2001-A1 Network module (SAFEDLINK) Mounting Installation

DXPE*J /215 ED. DIRECtIONAL CONtROL VALVE PILOt OPERAtED, WItH OBE AND FEEDBACK. Q max (see performance table) SERIES 30

SureSite Magnetic Liquid Level Indicator

Pressure transmitter For general industrial applications Model A-10

DTM04 TANK MONITOR DTM08 TANK MONITOR Dtm12 TANK MONITOR. Installation and Operation Manual

INSTALLATION AND MAINTENANCE INSTRUCTIONS FOR THREE PHASE INDUCTION MOTORS

48 SERIES Relay interface modules 10 A

Detector transparent with Color Inserts. FAA 500 TR P Trim Ring transparent with Color Inserts. FCA 500 / FCA 500 E Detector Bases

38 Series - Relay interface modules A

EZmoto V2. Product description Rev. 6 10/01/2014. EZmoto V2 Product description Rev.6 10/01/2014

Addendum to the Operating Instructions

Vert-X 16-5V / % Ub. Applications Servodrives Dancer arm Operating table

! WARNING. Before using product, read and understand instructions.

EE-SX91. Meeting Customer Needs with Compact Sensors that Mount with M3 Screws

Machine Safety Switch: SI-LM40 Series Limit Switch Style

Reliance DuraStar ORDINARY LOCATION INSTALLATION, OPERATING & MAINTENANCE INSTRUCTIONS

Material: Weight: Bearing Life: Shaft Speed: Starting Torque: Mass Moment of Inertia: Shaft Loads:

Square D Clipsal DIN-Rail Four-Channel Auxiliary Input Unit

BNI EIP Z009 IP67 Module, Unmanaged Switch

D.C. Motors. Products and specifications subject to change without notice.

SUGGESTED SPECIFICATION for Series 185 Service Entrance Rated Automatic Transfer Switches

Proportional relief valves type AGMZO-TERS, AERS two stage, with integral or remote pressure transducer, ISO 6264 size 10, 20 and 32

Transcription:

INSTRUCTION MANUAL Oil level indicator with pointer 5COL868200 REV.01 I

II

CONTENTS 1. SAFETY... 1 1.1 Safety instructions... 1 1.2 Specified applications... 1 1.3 Safety notes on the equipment operation... 1 2. DRAWINGS... 2 2.1 OLI... 2 2.2 eoli... 2 2.3 Mounting flange... 3 2.3.1 OLI/eOLI (radial)... 3 2.3.2 OLI/eOLI (axial)... 3 2.3.3 OLI-22 / eoli-22 (Radial)... 3 2.3.4 OLI-22 / eoli-22 (Axial)... 4 2.4 L140... 4 2.4.1 Radial... 4 2.4.2 Axial... 5 2.5 Viewer... 5 3. OPERATING PRINCIPLE... 6 3.1 Functioning... 6 3.2 Outputs... 6 3.3 Technical features... 6 3.4 Tests... 7 4. INSTALLATION... 8 4.1 Float assembly... 8 4.1.1 LA version (radial)... 8 4.1.2 LB version (axial)... 8 4.2 Oil level indicator: General information... 9 4.3 L140...10 4.4 OLI / eoli...10 4.5 OLI-22 / eoli-22 (with special flange)...11 4.6 Viewer...11 5. ELECTRICAL CONNECTION... 12 5.1 Micro-switches wiring...12 5.2 Analog output and Modbus communication wiring (for eoli and eoli-22)...13 5.2.1 Power voltage...13 5.2.2 Analog output...13 5.2.3 Modbus communication (optional)...13 5.3 Viewer wiring...13 5.3.1 Power voltage...13 5.3.2 Analog input...13 5.3.3 Viewer eoli connections...13 5 OPERATION AND MAINTANENCE... 14 6.1 Operation...14 6.2 Maintenance...14 6.3 Storage...14 APPENDIX A: MODBUS COMMUNICATION... 15 A1: MODBUS register...15 A1.1 MODBUS address...16

1. SAFETY 1.1 Safety instructions Make sure that any person installing: - Are technically qualified and competent. - Fully comply with these assembling instructions. Improper operations or misuse could cause danger to: Life and limb. To the equipment and other assets of the operator. To the equipment proper, function. Safety instructions in this manual are shown in three different forms to emphasize important information. WARNING This information indicates particular danger to life and health. Disregarding such a warning can lead to serious or fatal injury. CAUTION This information indicates particular danger to equipment and/or other property of the user. Serious or fatal injury cannot be excluded. NOTE This note gives important and specific information concerning the equipment. 1.2 Specified applications The oil level indicator is used in oil-insulated transformer to indicate the conservator tank oil level. Inside the device are usually installed up to four micro-switches to signal some critical oil levels. The micro-switches can give alarm or transformer power off signals. It is important to observe the limit values indicated on the nameplate and in the manual before commissioning the device. 1.3 Safety notes on the equipment operation Electrical installation is subject to the relevant national safety rules. It is mandatory to connect the grounding cable because of safety reason. CAUTION Installation, electrical connection and fitting the device have to be carried out by qualified personnel and only in accordance to this instruction manual. It is responsibility of the user to make sure that the device is used for specified application only. For safety matters, please avoid any unauthorized and improperly works. WARNING All relevant fire regulation must be strictly observed. 1

2.1 OLI 2. DRAWINGS 2.2 eoli Fig. 1 2 Fig. 2

2.3 Mounting flange 2.3.1 OLI/eOLI (radial) 2.3.2 OLI/eOLI (axial) Fig. 3 2.3.3 OLI-22 / eoli-22 (Radial) Fig. 4 3 Fig. 5

2.3.4 OLI-22 / eoli-22 (Axial) NOTE Mounting flange may be designed in accordance with customer s need: upon request, several hole patterns are available Fig.6 2.4 L140 2.4.1 Radial Fig. 7 4

2.4.2 Axial Fig. 8 2.5 Viewer 5

3. OPERATING PRINCIPLE 3.1 Functioning The level gauge with magnetic joint is composed of a sturdy, watertight body made of aluminum alloy powder coated to protect against corrosion. The movement of the float rod and the pointer takes place thanks to magnetic coupling and reaches a 120 angle. In this way, for every variation of the oil inside the conservator tank the movement of the float cause the rotation of the magnet joint with consequent variation of the indication on the dial of the gauge. The pointer indicate the level that the oil should reach at the temperatures printed on the dial. The electronic version of the oil level gauge provide an analogical and a digital signal proportional to the oil level inside the conservator. These signals can be remote to : PLC, PC, integrated monitoring system, Remote Indicator. An electronic level indicator equipped with 4..20 ma output signal can be coupled with the electronic Viewer. This device replicate the value of oil level (0-100%) at man-height. 3.2 Outputs STANDARD CONFIGURATION STANDARD (OLI-L140) OPTIONS (eoli) MICRO-SWITCHES ANALOG OUTPUT COMMUNICATION PORT RS-485 1, 2 or 4 change over contact (Fig.16) 4-20 ma (terminals 41-44) (Fig.17) (Minimum / Maximum resistance: 100 / 470 Ohm) Modbus communication (terminals 3-4)) (Fig.17) 3.3 Technical features Table 1 Material Dial All the external parts are resistant transformer oils, salt fog and UV rays. Tempered glass / Polycarbonate Standard color White RAL 9002** Ambient temperature Oil temperature Degree of protection Standard cable gland Wires Electronic board features, only for eoli Power supply (terminals 1-2) Power consumption Analogical output (terminals 5-6) Distance for analogical output Digital output (terminals 3-4) Distance for digital output Ventilation Valve Micro-switches features Power supply Power supply interruption -40 C +85 C -40 C +120 C IP65 according to EN60529 1 x M25x1.5 OLI L140 3 x M25x1.5 eoli Max 2.5mm 2 advised 4x1mm 2 o 6x1mm 2 shielded twisted pair cable 24 Vdc ±10% polarized 0,5 W 4 20 ma (dielectric strength between electronic card and analogical output:1kv) Minimum / Maximum resistance: 100 / 470 Ω Max 30 m / 98 ft (for different demands contact COMEM) Serial RS485 Modbus RTU (for more information contact COMEM assistance dept.) Max 30 m / 98ft (for different demands contact COMEM) n.2 to prevent the formation of condensation 24V 220V ac/dc 3A 125/250V ac (resistive) 0.5A 125V dc for inductive load L/R=40ms 0.25A 250V dc for inductive load L/R=40ms 6

Electronic board features, only for Viewer Power supply (terminals 1-2) Analogical input (terminals 3-4) Distance for analogical input 24 Vdc ±10% polarized 4 20 ma (dielectric strength between electronic card and analogical output:1kv) Minimum / Maximum resistance: 100 / 470 Ω Max 30 m / 98 ft (for different demands contact COMEM) ** For critical environmental conditions please contact Comem Table 2 3.4 Tests Description Reference standard Description Reference standard Fast transient/burs immunity test IEC 61 000-4-4 Emission standard IEC 61 000-6-3 (EN 55022) Conducted disturbances IEC 61 000-4-6 Harmonic current emission EN 61000-3-2 Electrostatic discharge IEC 61 000-4-2 Voltage fluctuations and flicker EN 61000-3-3 Supply variation IEC 61 000-4-11 IP degree - IP 65 CEI EN 60259 Surge immunity test IEC 61 000-4-5 Vibration Test CEI EN 60721-3-4 (Class 4M4) Magnetic field immunity test IEC 61 000-4-3 Vibration Test IEC 60068-3-3 Power frequency magnetic field IEC 61 000-4-8 Table 3 7

4. INSTALLATION CAUTION The operating and the installation requirements described in this manual must be strictly following. If not, the device can be damaged or a malfunction can occur. 4.1 Float assembly 4.1.1 LA version (radial) Screw the arm (Fig 9/A) into the hole of the backside shaft and block it with the M4 nut (Fig.9/B). A B Fig. 9 4.1.2 LB version (axial) Insert the arm into the slot (Fig.10/A) on the backside shaft with and block it with the M5 nut (Fig.10/B). Fig. 10 A B 8

4.2 Oil level indicator: General information CAUTION Verify contact surface of the conservator. It must be well leveled with a good degree of roughness (Ra=3.2 micrometer). Verify and in case remove all welding burrs to ensure that the welding will not interfere with the housing flange holes. During the flange assembly, COMEM advice to apply a few drops of cyanoacrylate glue on the gasket to fix it at the oil level flange. This action guarantees a good gasket positioning and it facilitates the assembly Apply a specific tightening torque (max 20 Nm) on the nuts following a cross sequence. Depending on the conservator design, the level gauge can have different values of the parameters R and S (Fig.11) according to the table 4. Table 4 Fig. 11 - S : parameter that indicates an offset from the vertical conservator axis [mm]. It is available for LA (radial) configuration. - R : parameter that indicates the length of the rod [mm]. It is available for LA (radial) and LB (axial) configurations. - ØDC : conservator diameter [mm]. NOTE For the LB configuration COMEM advice to fit it in the center of the conservator (S=0 mm) 9

4.3 L140 Insert the arm with float through the machined hole on the conservator. Place the o-ring on the slot behind the gauge. Insert the device on the threaded pin of the conservator flange (Fig12/A). The oil level indicator has to be mounted using the items (Fig.12/B) showed in the table 5. Q.ty Description Reference standard B 6 Ø6 plane washer UNI 6592 6 Ø6 grower washer UNI1751 6 M6 nut UNI5588 A 1 OR6362 - Table 4 Fig. 12 4.4 OLI / eoli Align the flange (Fig.13/C) with the threaded pins or holes (Fig.13/A) (depending on the conservator flange type) and positioning between the conservator and the flange the flat gasket (Fig.13/B). The oil level indicator has to be assembled on the flange using four screws M4x12 (Fig.13/D). The oil level indicator flange has to be assembled using the items showed in the table 5. Qty Description Reference standard 4 Ø12 plane washer UNI 6592 4 Ø12 grower washer UNI1751 A 4 M12 nut UNI5588 B 1 Flat gasket - C Table 5 D Fig. 13 10

4.5 OLI-22 / eoli-22 (with special flange) Insert the arm with float through the machined hole on the conservator. Place the o-ring in the slot behind the flange (Fig.14/C). Insert the flange on the threaded pins (Fig.14/A) of the conservator flange and fix it with the items showed in the table 6 (Fig.14/B). Fix the gauge on the flange using 4 screws M4x12 (Fig.14/D)). Q.ty Description Reference standard 8 Ø10 plane washer UNI 6592 8 Ø10 grower washer UNI1751 A 8 M10 nut UNI5588 1 OR221 - Table 6 B C D Fig. 14 4.6 Viewer Arrange the transformer with a dedicated place following the scheme in the figure 15. The connection can be done in two alternative way: - threaded pin - screws Fig. 15 11

5. ELECTRICAL CONNECTION CAUTION Qualified and skilled personnel trained in the applicable health and safety regulations of the relevant country should only perform electrical connections. WARNING Dangerous electrical voltages! It is imperative to deactivate the power supply during wiring of the device. CAUTION During the terminal box assembly, use caution not to damage the OR gasket (Fig.15/C). If this occurs, it must be substituted. If you do not use all the cable glands, pay attention to close the free cable gland with a plug with gasket. Remove the cover from the terminal box unscrewing the 4 captive screws M4 (Fig.15/C)). Insert the wires through the cable gland (Fig.15/B) and wiring them following the electrical scheme (Fig.16-17). C A B Fig. 15 5.1 Micro-switches wiring Wire the electrical cables in accordance with the ordered model following the electrical scheme showed in the Figure 16. It is possible to identify the wiring diagram from the device part number: E.g.: 1LB44X0000 the 5th letter identify the wiring diagram of the micro-switches DIAGRAM K DIAGRAM Y DIAGRAM X DIAGRAM W 12 Fig. 16

5.2 Analog output and Modbus communication wiring (for eoli and eoli-22) 5.2.1 Power voltage Connect the power voltage (as written on the label on the terminal box cover) to terminals 1-2. 24 Vdc ±10% polarized 5.2.2 Analog output Terminals for analog output 4-20 ma: 5-6 Minimum / Maximum resistance: 100 / 470 Ω 4 ma = 0% (minimum arrow position) 20 ma = 100% (maximum arrow position) 5.2.3 Modbus communication (optional) Digital output RS485: terminals 3-4 (for the Modbus register and address, see the Appendix A) Fig. 17 5.3 Viewer wiring 5.3.1 Power voltage Connect the power voltage (as written inside the terminal box, fig.18) to terminals 1-2. 24 Vdc ±10% polarized 5.3.2 Analog input Connect the analog signal (as written inside the terminal box, fig. 18) to terminals 3-4. 4..20 ma Fig. 18 5.3.3 Viewer eoli connections The following scheme (fig.19) describes the connections for signal remoting between an electronic oil level indicator and the viewer. 13 Fig. 19

5 OPERATION AND MAINTANENCE The oil level indicator devices are ready for operation after installation, electrical connection and power supply. 6.1 Operation It is possible to detect the conservator oil level observing the indicator dial: Minimum level: when the pointer indicates the MIN position Maximum level: when the pointer indicates the MAX position. The electrical micro switches operate at an advance angle 5, with respect to the min or max indications of the oil level in the conservator. When there is a double contact, for e.g. double MIN and/or double MAX (schemes Y o W) the second contact operates at about 5 after the first contact. NOTE Comem advices to disconnect the eoli/eoli-22/viewer during the electrical transformer routine test 6.2 Maintenance During regular maintenance on the transformer, we recommend performing the following checks on the oil level indicator: Check the exterior condition of the device Remove dirt as necessary. 6.3 Storage The oil level indicators can be handled without any tools. Handle the device with care. CAUTION Not to paint the device. In this case any guarantees concerning the corrosion resistance decline. Only mild soap and water should be used to clean the electrical box cover. Solvents must not be used for any reason as they will degrade the performance of the paint. Use of solvents on the unit will immediately void the warranty. When you install the device, please follow section 4, 5 and 6. The oil level indicator must be stored in the original packing and in a dry place with temperature in the range -10 40 C (14 104 F). Upon receiving the device, please check: The outer surface of the packaging to ensure that it is intact That there are no breakages If damages are found, please contact COMEM and provide the information from the shipping list and the serial number. 14

APPENDIX A: MODBUS COMMUNICATION A1: MODBUS register Register address Operation Notes Operation for monitoring 0x2000 R Level value (0-100%) 0x2001 R Minutes from the last powering 0x2002 R Days from the last powering 0x2003 R Max level value (%) in the current day 0x2004 R Min level value (%) in the current day 0x2005 R Number of powering lost in the day 0x2006 R Minimum range value 0x2007 R Maximum range value 0x200A R Software version 0x2100 R Max level in the day 1 0x2101 R Min level in the day 1 0x2102 R Max level in the day 2 0x2103 R Min level in the day 2 0x2104 R Max level in the day 3 0x2105 R Min level in the day 3 Data logging 0x215C R Max level in the day X 0x215D R Min level in the day X 0x215E R Max level in the day Y 0x215F R Min level in the day Y 0x2300 R Events number 0x2301 R Timestamp Hi [Event 1]* 0x2302 R Timestamp Low [Event 1]* 0x2303 R Event type: value 4=Change Date[Event 1] 0x2304 R Level Value at the moment of the event [Event 1] 0x248D R Timestamp Hi [Event 100]* 0x248E R Timestamp Low [Event 100]* 0x248F R Event type: value 4=Change Date[Event 100] 0x2490 R Level Value at the moment of the event [Event 100] Events logging Table 7 *Date and time of an event are calculated in this way: Event Date/Time = Timestamp Hi (seconds) + (2 16 ) x Timestamp Low (seconds) + (01-Jan-2014 00hh:00min:00sec) 15

A1.1 MODBUS address When are installed two or more units, it is necessary to differentiate the MODBUS address changing the dip-switches position The available eoli addresses are 128(default) to 143 4 3 2 1 ADDRESS OFF OFF OFF OFF 128 OFF OFF OFF ON 129 OFF OFF ON OFF 130 OFF OFF ON ON 131 OFF ON OFF OFF 132 OFF ON OFF ON 133 OFF ON ON OFF 134 OFF ON ON ON 135 ON OFF OFF OFF 136 Fig. 18 ON OFF OFF ON 137 ON OFF ON OFF 138 ON OFF ON ON 139 ON ON OFF OFF 140 ON ON OFF ON 141 ON ON ON OFF 142 ON ON ON ON 143 Table 8 16

Strada Regionale 11, Signolo 22 36054 Montebello Vic.No (VI) - Italy Tel. +39 0444 449311 - Fax -39 0444 449352 440359 http://www.comem.com e-mail:comem@comem.com 17