Series GM. Peerless Boilers. Residential/Commercial Gas Boilers



Similar documents
High efficiency, cast-iron gas boiler

GALAXY. High performance gas boilers HOT WATER AND STEAM NATURAL AND L.P. PROPANE GASES

Commercial Gas Water Heaters

Condensing Boilers. High Efficiency. Proven Reliability, American-Made Home Heating Comfort. ANYWHERE UNMATCHED

Advanced Heating & Hot Water Systems. Ultra High Efficiency Energy Star Listed Condensing Boiler

G234X-55 Conventional Gas Boiler

Residential/Commercial Gas Condensing High Efficiency Tankless Water Heaters

Commercial Semi-Instantaneous Water Heaters

SIOUX HYBRID WATER HEATER

Technical Data Manual Model Nos. and pricing: see Price List

Commercial Gas Water Heaters

M7RL Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. High Efficiency / Direct Vent Condensing Downflow Gas Furnace

SECTION PACKAGED ROOFTOP AIR CONDITIONING UNITS NON-CUSTOM

LAKE COUNTY ANIMAL SERVICES EXPANSION SECTION 15459

Indirect-Fired Storage Water Heater Models WH-30 through WH-80 INSTALLATION AND OPERATING INSTRUCTIONS

Electric Flow Boiler

Commercial Gas Furnace Upflow

Buderus. Superior Equipment by Design. Comfortable. Efficient. Intelligent Heating. G315 G515 G615 Cast Iron Commercial Boilers.

APG-4R_Layout 1 9/14/11 12:01 PM Page 1 APG-4R XL X F L

NAVIEN AMERICA INC FITCH AVENUE

Commercial Gas Water Heater

Centauri. Condensing Fire Tube Water Boiler 399 to 1000 MBH

RESIDENTIAL HEATING OIL SERVICE CONTRACT ANNUAL COST $276.00

Better Boilers.

ASME Packaged Indirect Fired Water Heater

G26 Corp L11 Revised LENNOXOEMPARTS.COM. Service Literature G26 SERIES UNITS

Light Duty Commercial Electric Water Heater

2010 Residential Water Heater Replacement Check List

Buderus. Flexible Energy Efficient Solutions. Comfortable. Efficient. Intelligent Heating. GB312 Series Natural Gas Condensing Boiler.

Cooling Capacity CFM in. w.c. (125 Pa)

Mega-Stor INSTALLATION AND OPERATING INSTRUCTIONS ENGINEERING MANUAL MAINTENANCE PARTS

CHAPTER 10 BOILERS, WATER HEATERS AND PRESSURE VESSELS

! WARNING. McDonnell & Miller Installation & Maintenance Instructions MM-217(I) Series 150S and 157S (Snap Switch, All Models except 157S-RB-P)

48/50EJ,EK,EW,EY038, 044, 048 SINGLE-PACKAGE COOLING UNITS VARIABLE VOLUME CONSTANT VOLUME FACTORY-INSTALLED OPTIONAL HEAT

GAS CONVERSION PROJECT ˆAn Alternative to Oil

HEAVY DUTY STORAGE GAS

Gas Unit Heaters Duct Furnaces Horizontal - 60 HZ Form No. LF (10/2011) LF24 Standard

BUILDING PERFORMANCE INSTITUTE TECHNICAL STANDARDS

XV80 UPFLOW/HORIZONTAL 2-STAGE, VARIABLE SPEED GAS-FIRED FURNACE

TECHNICAL GUIDE 95.5% SINGLE STAGE GAS-FIRED RESIDENTIAL MULTI-POSITION GAS FURNACES MODELS: TG9S DESCRIPTION FEATURES

Operators manual Basic water heater

TANKLESS WATER HEATER INSTALLATION DIAGRAMS

INSTALLATION INSTRUCTIONS

Commercial Boiler Systems and Controls

Cast-Iron Performance Meeting today s commercial demands with effi ciency, strength and intelligent controls.

AMX300 DirectConnect Mixing Valve Kits

D248 Series Cast Iron Commercial Steam Boiler

C. Burner management system to follow requirements of Industrial Risk Insurers (IRI).

Cooling Capacity CFM in. w.c. (125 Pa)

Cooling Capacity CFM in. w.c. (125 Pa)

Hot Water Heating: Technologies and Use

Commercial Storage Tanks

ASPE Seminar Water Heater Piping Strategies. Presented by Joe Kalarickal, EIT Regional Sales Manager AERCO International

Replacement parts. WM97+ gas-fired water boiler Boiler Manual. OBTAIN PARTS ONLY THROUGH WEIL-McLAIN THE BOILER CONTAINS CERAMIC FIBER MATERIALS

An old boiler can cost you It doesn t stop there A modern solution

MODEL TF, RF & SF GAS-FIRED TUBULAR UNIT HEATERS

Tankless Water Heater A Primer for Contractors, Installers, Builders and Homeowners

CHAPTER 9: WATER HEATING

Boiler Preparation, Start-Up and Shutdown

Range Tribune HE Solar Unvented Direct and Indirect Cylinders

XV 95. Upflow/ Horizontal Left, Downflow/ Horizontal Right Variable Speed Two Stage Condensing Gas-Fired Furnace PUB. NO.

Gas-Fired, Residential Storage Type Water Heaters

MODEL BRT GAS-FIRED TUBULAR UNIT HEATERS

One Year Warranty. Stock U.S. # of Volts Weight CONN. Height Dia. Watts # GAL. Elements INS. Inches NATURAL GAS* Six Year Warranty

Boiler and Burner Cleaning and Servicing Specifications

CROWN BOILER COMPANY BWF SERIES BOILER CATEGORY I VENT KIT INSTALLATION AND OPERATING INSTRUCTIONS

C18 ACERT Fire Pump Tier bkw/ rpm

Boiler Plan II Table of Contents

High Efficiency Copper Finned Tube Boilers 750,000-2,000,000 BTU/HR

Electric & Gas Water Heaters

Mechanical Rooftop Custom Capabilities

Hot Water Boilers and Controls Why Condensing Boilers are Different. Presented Oct. 14, 2008 Long Island Chapter, ASHRAE

Up To 99% Thermal Efficiency HIGH EFFICIENCY COMMERCIAL BOILERS WITH MODBUS PROTOCOL, CASCADING SEQUENCER AND FRONT-END LOADING CAPABILITY

OIL FURNACES CLASSIC PREMIUM CLASS UPFLOW OIL FURNACES. ROBD- SERIES Heating Capacities 56,000 to 151,200 BTU/HR [16.41 to 44.

36G22, 36G23, 36G24 & 36G52 36J22, 36J23, 36J24 & 36J52 DSI and HSI Single Stage Combination Gas Valve

Versatility ::::::::::::::::::::::::::::::::::::::: the best. mod/con Performance. and UP TO.

PLP - TERMS AND CONDITIONS

SPIDERfire: Delivers high efficiency and real savings for today s businesses

Therm-Omega-Tech, Inc. Therm-Omega-Tech, Inc. MODEL EMV. A Heavy Duty, Reliable Source For Tepid Water Delivery. Model EMV

TANKLESS DURABILITY Tankless Product Guide

DRAFT HOOD OUTLET GS6-30-YORT NG Select - Tall - C3 Technology 28 FIRST HOUR RATING BTU INPUT PER HOUR

I N S T A L L A T I O N I N S T R U C T I O N S F O R T H E H i l k o i l Energy S aving Hot Water Kit

Select Radiators Installation Guide

OTF Oil Fired Pool Heater

Principals of Condensing Boiler System Design

Commercial Gas Water Heaters

Originators of the Flexible Water Tube design

DIESEL-FUELED, BLOWN AIR, DUCTABLE HEATERS

Commercial Electric Water Heater

301.7D. Mini Hydraulic Excavator

Your safety and the safety of others are very important.

VC Series Zone Valves BALANCED 2-WAY AND 3-WAY HYDRONIC VALVES

Tankless water heaters

Inventory Management Guide

PRODUCT PRODUCT CODE TECHNICAL INSTRUCTIONS PAGE

1 DESCRIPTION OF THE APPLIANCE

ECOCIAT. Domestic hot water heat recovery unit

Hot Water Makers. Efficiency at its Best

FLASH TANK ECONOMIZER PRODUCT GUIDE

Transcription:

Peerless Boilers Series GM Residential/Commercial Gas Boilers The Series GM cast iron, hot water boiler is ideal for use in large residences or commercial applications. This gas-fired, atmospheric boiler is designed for use with a conventional chimney for simple installations. Available in four sizes, the Series GM boiler features front mounted controls in the boiler vestibule for safe operation and easy servicing. Boilers are available with 30, 50, 80 or 100 psi safety relief valves, and are packaged and designed with the return piping located in the front and the supply piping at the top/front of the boiler. These features provide installation flexibility and allow the Series GM boiler to be used for any single, modular, or multiple boiler job. A vertical draft hood and deluxe insulated enameled steel jacket are standard on all Series GM boilers. Five and sixsection boilers feature a standard vent damper (optional on seven and eight-section boilers). Steel push nipples on all boilers assure a water-tight seal between sections for a lifetime of dependability. All Series GM natural gas boilers are available with standard intermittent ignition provided by the Honeywell SmartValve System. This system provides the safety and ignition functions in one device for simple, dependable operation. Series GM LP gas boilers are available with intermittent spark ignition. Five and six-section boilers are also available with optional standing pilot ignition. The Series GM five and six-section boilers exceed the federal standards for residential AFUE and the seven and eight-section boilers meet the ASHRAE 90.1 efficiency minimum as required by federal standards for commercial boilers. SmartValve is a registered trademark of Honeywell Corporation.

A quality casting is the foundation for all our cast iron boilers. Hard work and dedication by skilled employees have made us one of today s top cast iron boiler manufacturers. From the beginning, our main priority has been to serve customers needs and to provide them with the best built cast iron boilers on the market. That commitment, still true today, is evident in all of our products and services. Packaged Residential/Commercial Hot Water Boilers Natural Gas and LP Gas Natural Draft Venting Honeywell SmartValve Intermittent Ignition (Standard on Natural Gas 5-8 Section), Intermittent Spark Ignition (Standard on LP Gas 5-8 Section) or Standing Pilot (Optional on 5-6 Section) Steel Push Nipples Series GM Standard Equipment Cast Iron Sections - Factory Tested and Assembled with Steel Push Nipples Deluxe Insulated Enameled Steel Jacket 30 PSI Safety Relief Valve (unmounted) Honeywell SmartValve Intermittent Ignition (Natural Gas) Intermittent Spark Ignition (LP Gas) Honeywell Limit Control Drain Valve (unmounted) Temperature-Pressure Gauge and Tee (unmounted) Vertical Draft Hood Vent Damper (5-6 section) Flame Rollout Safety Shutoff Switch Vent Safety Shutoff Switch Series GM Optional Equipment Taco 0010 & 0012 Circulators (unmounted) Taco 0010 & 0012 Zoning Circulators with Relay (unmounted) 50, 80 or 100 PSI Safety Relief Valve (unmounted) Probe Type LWCO (unmounted) Standing Pilot Ignition (5-6 section) Vent Damper (7-8 section) Honeywell SmartValve Intermittent Ignition

The Peerless Partner indirect-fired water heater provides a true advancement in hot water generation. By utilizing the Series GM boiler as its heat source, the boiler fires only when necessary and transfers heat energy from the boiler to the water heater through a highly efficient cupronickel, fin-tube heat exchanger. The heater functions as a separate heating zone and water movement is regulated from the boiler through the heater coil by a separate circulator or zone valve. Peerless Partner Indirect-Fired Water Heater Standard Equipment High-Grade 316L Stainless Steel Tank Enclosed Thermostat Well Maintenance-Free Plastic Jacket Adjustable Honeywell Control 2 Polyurethane Foam Insulation T&P Relief Valve Cupronickel, Fin-Tube Heat Exchanger The Peerless Partner water heater has two or more times the recovery rate of gas-fired water heaters and supplies as much as five times the amount of hot water as a comparably sized electric water heater. Because of its light weight and durable plastic jacket, the Partner water heater is easy to install and virtually maintenance free. Combine the Peerless Partner indirect-fired water heater with the Series GM boiler as part of the Flex-Heat Hydronic Comfort System for efficient and sensible heating applications. Modern Coil Design Minimal Standby Temperature Loss Rapid Recovery Rate Easy Installation Long Lasting Stainless Steel Construction No Separate Chimney or Burner Needed We have one of the most comprehensive warranty programs in the industry. Unlike other boiler manufacturers that pro-rate their warranties, we offer full cost warranties (up to the original cost of the boiler). All our commercial and residential cast iron boilers include a limited, one-year warranty on the entire boiler. A limited, ten-year warranty is provided on the cast iron sections of Series GM boilers used for commercial installations. We also provide a limited, lifetime warranty on the cast iron sections of Series GM boilersused for residential installations. Five and ten year extended warranties on parts and labor are available for both residential and commercial boilers. This summary is not a specific warranty. Consult us for complete details on all of our cast iron boiler warranties. The warranties describe what is considered a residential application and what is a commercial application. All written warranties are available from Peerless Boilers. For additional information on our products and services, visit our website at PeerlessBoilers.com. Loaded with valuable information, this user-friendly tool is a quick and easy way to answer many of your heating questions.

Boiler Model GM-05 GM-06 GM-07 GM-08 MBH 228 285 342 399 kw 66.8 83.5 100.2 116.9 Heating Capacity¹ MBH 187 231 Series GM Boiler Ratings Heating Capacity¹ Output² Output² kw MBH kw 54.8 67.7 280 327 82.1 95.8 Net I=B=R Ratings Water³,4 MBH Net I=B=R Ratings Water³,4 kw 47.8 58.9 71.2 83.2 Standing Pilot Seasonal Efficiency (AFUE) 1 Intermittent Ignition Seasonal Efficiency (AFUE)¹ 82.1 81.1 1 Heating Capacity and Annual Fuel Utilization Efficiency (AFUE) ratings are based on U.S. Government test. 2 Output rating and combustion efficiency determined in accordance with ANSI Z21.13, Gas-Fired Low-Pressure Steam and Hot Water Boilers. 3 Net I=B=R water ratings based on an allowance of 1.15. 4 Consult factory before selecting a boiler for installations having unusual piping and pickup requirements, such as intermittent system operation extensive piping systems, etc. 163 201 243 284 81.0 80.0 Combustion Efficiency² 82.0 82.0 Boiler Model GM-05 GM-06 GM-07 GM-08 Jacket Width A Left of Jacket to the Centerline of Vent B Boiler Dimensions Top of Jacket to Vent Connector C Vent Connector Size D USA, Nat Gas Canada or LP Water Content (inch) (mm) (inch) (mm) (inch) (mm) (inch) (mm) (inch) (mm) (gal) (liters) 19-1/4 22-3/4 26-1/4 29-3/4 489 578 667 756 9-3/4 11-1/2 13-1/4 15 248 292 337 381 29 30 31 31 737 762 787 787 7 8 9 9 178 203 229 229 8 9 10 10 203 229 254 254 6.15 7.20 8.25 9.30 23.3 27.3 31.2 35.2 Boiler Model GM-05 GM-06 GM-07 GM-08 Crate Dimensions & Shipping Weights Width Depth Height Approximate Shipping Weight (inch) (mm) (inch) (mm) (inch) (mm) (lb) (kg) 28 28 35 35 711 711 889 889 433 500 574 641 196 227 260 291

The Peerless Flex-Heat Hydronic Comfort System combines Series GM boilers in single, multiple or modular arrangements with the Peerless Partner indirect-fired water heater, modern system controls, circulators and a design application guide to provide efficient, economical space and domestic hot water heating. Modular boiler systems require fewer limit controls and low water cut-offs than multiple boiler systems. On modular boiler systems, only one limit control on each boiler and one system limit control and low water cut-off are required. On multiple boiler systems, two limit controls are required on each individual boiler and, if the boilers are larger than 400 mbh input, a low water cut-off is also required on each boiler. Stop Valves Low Water Low Water Low Water Limit Limit Limit Limit Limit Limit To qualify as a modular boiler system, ASME 1 adds the following requirements versus a multiple boiler system: 1. Modules can be no larger than 400 mbh gas input (all Series GM boilers meet this requirement.) Low Water s and 2nd Limit Required if Boilers Over 400 MBH MULTIPLE BOILER SYSTEM Each Unit Treated as a Separate Boiler 2. No isolation or stop valves can be placed between modules and the main headers. Limit Low Water If ASME CSD-1 applies in your area, the low water cut-off(s) and additional limit control(s) must be manual reset. Limit Limit Limit 400 MBH 400 MBH 400 MBH or Less or Less or Less MODULAR BOILER SYSTEM Treated as if a Single Boiler Modular systems have higher overall boiler plant efficiency than typical single large boiler installations. Higher part load efficiency Atmospheric gas boilers operate most efficiently at full gas input rate. The FLEX-HEAT system energizes each boiler at its full gas input and efficiency and controls the system by modulating the number of energized boilers. Lower stand-by losses Since the FLEX-HEAT system energizes only the number of boilers needed to meet the heat demand, less heat is dissipated to the boiler room and less heat escapes up the chimney. FLEX-HEAT Circulator Kits further reduce stand-by losses by preventing heated water from flowing through idle boilers. Modular systems are redundant. If one boiler shuts down, the remaining boilers will provide heat until the problem boiler can be corrected. If a single boiler installation shuts down, it s a no heat situation. Modular systems can also be easier to maintain. The Series GM boilers are pre-packaged and fit through a standard doorway, requiring less time to replace than changing a section of a single, large boiler. 1 ANSI/ASME Boiler and Pressure Code, Section IV: Rules for Construction of Heating Boilers.

Typical Series GM Flex-Heat Modular Boiler Systems System Module Quantity & Size (MBH) Gross Output (MBH) Gross Output (H.P.) Net Output (MBH) Combustion Efficiency FH-456 FH-513 FH-570 FH-627 FH-684 FH-741 FH-798 FH-855 FH-912 FH-969 FH-1026 FH-1140 FH-1197 FH-1254 FH-1368 FH-1482 FH-1539 FH-1596 FH-1710 FH-1824 FH-1881 FH-1938 FH-1995 FH-2052 FH-2166 FH-2280 FH-2394 FH-2508 FH-2622 FH-2736 FH-2793 FH-2850 FH-2964 FH-3021 FH-3078 FH-3192 FH-3306 FH-3363 FH-3420 FH-3534 FH-3591 FH-3648 FH-3762 FH-3876 FH-3990 2-5 1-5, 1-6 2-6 1-6, 1-7 2-7 1-7, 1-8 2-8 3-6 2-6, 1-7 1-6, 1-7 3-7 1-7, 2-8 3-8 2-6, 2-7 4-7 2-7, 2-8 1-7, 3-8 4-8 5-7 3-7, 2-8 2-7, 3-8 1-7, 4-8 5-8 6-7 4-7, 2-8 2-7, 4-8 6-8 5-7, 2-8 3-7, 4-8 1-7, 6-8 7-8 6-7, 2-8 4-7, 4-8 3-7, 5-8 2-7, 6-8 8-8 5-7, 4-8 4-7, 5-8 3-7, 6-8 1-7, 8-8 9-8 6-7, 4-8 4-7, 6-8 2-7, 8-8 10-8 456 513 570 627 684 741 798 855 912 969 1026 1140 1197 1254 1368 1482 1539 1596 1710 1824 1881 1938 1995 2052 2166 2280 2394 2508 2622 2736 2793 2850 2964 3021 3078 3192 3306 3363 3420 3534 3591 3648 3762 3876 3990 374 421 467 514 561 608 654 701 748 795 841 935 982 1028 1122 1215 1262 1309 1402 1496 1542 1589 1636 1683 1776 1870 1963 2057 2150 2244 2290 2337 2430 2477 2524 2617 2711 2758 2804 2898 2945 2991 3085 3178 3272 11.2 12.6 14.0 15.4 16.8 18.2 19.5 20.9 22.3 23.7 25.1 27.9 29.3 30.7 33.5 36.3 37.7 39.1 41.9 44.7 46.1 47.5 48.9 50.3 53.1 55.9 58.6 61.4 64.2 67.0 68.4 69.8 72.6 74.0 75.4 78.2 81.0 82.4 83.8 86.6 88.0 89.4 92.2 94.9 97.7 325 366 406 447 488 528 569 610 650 691 732 813 854 894 975 1057 1097 1138 1209 1301 1341 1382 1423 1463 1544 1626 1707 1788 1870 1951 1992 2032 2113 2154 2195 2276 2357 2398 2439 2520 2561 2601 2682 2764 2845 Installed By: PeerlessBoilers.com 2006 HI Division of gama ASME CUT-GM R6 (6/06-15M) Printed in U.S.A.