MULTI-FIELD EMF METER. TM-190 User s Manual B2TM1900001



Similar documents
Multi Media Cable Tester TM-901N/TM-902/TM-903

Microwave Meter. Instruction Manual

EM90 INFRA-RED THERMOMETER & THERMOCOUPLE METER

AutoRanging Digital MultiMeter

RS Stock No Instruction Manual RS-1340 Hot Wire Anemometer

IDEAL INDUSTRIES, INC. TECHNICAL MANUAL MODELS:

User Guide. Model Insulation Tester / Megohmmeter

UT202A Operating Manual. Contents

The table below lists the symbols used on the Clamp and/or in this manual. Important Information. See manual.

COLOR TFT LCD MONITOR. User Manual

RS DIGITAL THERMOMETER

User's Guide. Digital Psychrometer. Model RH390. F C WBT Dew Point MAX MIN

Manual Ranging MultiMeter

Programmable Room Thermostat 7 Day (5-2 Day) Models: / Power Supply: Battery / Mains

VOLTAGE/CURRENT CALIBRATOR ISO-TECH ILC-421

EPM3. Phase Sequence and Motor Rotation Tester. Users Manual

T TPMS Tool Manual 1. T55003 INTRODUCTION 2. KEYPAD SUMMARY AND FUNCTIONS

Drayton Digistat +2RF/+3RF

IN-OUT Thermometer with Cable Free Sensor and Clock

Ground Resistance Clamp On Tester

Model UT33A: OPERATING MANUAL Table of Contents (1)

4-Channel Thermometer / Datalogger

Model UT713 OPERATING MANUAL

Pocket Tach 99 (PT99) Non-Contact Tachometer

RDJ10RF/SET. Wireless room temperature controller with 24-hour time switch and LCD. Programmable, for heating systems

Temperature Humidity Meter

User Guide. 4 wire Earth Resistance Tester Model GRT300

How To Use A Power Supply Unit (Upu)

Dual Laser InfraRed (IR) Thermometer

Mini InfraRed Thermometer with Laser Pointer

User's Guide. True RMS Industrial Multimeter

Point of view HDMI Smart TV dongle Mini RF Keyboard

Daker DK 1, 2, 3 kva. Manuel d installation Installation manual. Part. LE05334AC-07/13-01 GF

Model UT201/202: OPERATING MANUAL. Table of Contents

USER GUIDE. LED Light Meter. Model LT45

REGULINE 600VA / 1000VA REGULATOR USER MANUAL

focus TOuCh P10 FOR DISPLAYS: 55, 70 AND 82 ENgliSh V

USER MANUAL V5.0 ST100

1587/1577. Insulation Multimeters. Technical Data. Two powerful tools in one.

TFT LCD COLOR MONITOR OPERATION MANUAL

1. SAFETY INFORMATION

Light Meter (Foot Candles)

User s Manual AURORA 1.2K/2.2K

Auto-ranging Digital Multimeter INSTRUCTION MANUAL

Getting started with

FPV MONITOR. User Manual

24 Wide Screen LED Monitor with HDMI

DVB-T 730. User s Manual

Model: Manual DC: WIRELESS COLOR FORECAST STATION

INSTRUCTION MANUAL PLEASE READ ALL THE INSTRUCTIONS COMPLETELY BEFORE USE AND SAVE THIS MANUAL FOR FUTURE REFERENCE

SAFETY WARNINGS. Important Safety Instructions. FCC Notice. Caution

e-4 AWT07MLED 7 Q TFT LCD MONITOR (LED Backlighted) USER MANUAL

Introduction. Refrigerant Leak Detecting System. Feature and Benefits

Model UT33B/C/D: OPERATING MANUAL Table of Contents (1)

How To Use A Cdm250 Digital Multimeter

Hygro-Thermometer + InfraRed Thermometer Model RH101

INSTRUCTION MANUAL IPM Phase Power Analyser EN FR IT DE ES

Single Day Alarm Clock with. Bluetooth and USB Play-through

Agilent U1230 Series Handheld Digital Multimeters (DMMs)

12 Volt 30 Amp Digital Solar Charge Controller

DC POWER SUPPLY ALIMENTATION C.C.

LCD Drawer User Manual

DAB+ / FM Tuner Model: TU-201

User's Guide. Pinless Moisture Meter. Model MO257

INSTALLATION AND OPERATION MANUAL

AM / FM Tuner + RDS. Model: TU

Instruction Manual for IV-08MTV LCD Color Monitor

Integrating Sound Level Meter and Datalogger

Wireless Indoor/ Outdoor Thermometer

PD30ETB20xxIS. Photoelectrics, Background Suppression reflective with IR light. Main features. Description

INSTRUCTION MANUAL PLEASE READ ALL THE INSTRUCTIONS COMPLETELY BEFORE USE AND SAVE THIS MANUAL FOR FUTURE REFERENCE

User Guide. Heavy Duty Dissolved Oxygen Meter. Model

USER S MANUAL. MaxPower UPS. Uninterruptible Power System 28-2MAXPO0018

SNMP Web Management. User s Manual For SNMP Web Card/Box

MAGICAR M871A. Car alarm with two-way remote User s guide

Dual Laser InfraRed (IR) Thermometer with Color Alert

HCS-3300/3302/3304 USB Remote Programmable Laboratory Grade Switching Mode Power Supply

Wide Range InfraRed (IR) Thermometer with Type K input and Laser Pointer

Nardalert S3 Non-Ionizing Radiation Monitor

User s Manual Before using the inverter, you need to read and save the safety instructions.

Pocket DAB & FM Radio with Speaker

Model: v2 Quick Setup Guide DC: Atomic Projection Alarm with Indoor and Outdoor Temperature

COMPLETE MANUAL. Version: Optic. September 2015 (English), version 1.0. EnergyOT Optic Developed and Manufactured by Genoa Spark, lda Made in Portugal

User Manual Color video door phone

Android Tablet User Manual

User s manual FLIR VP50/VP52 Non-contact AC voltage detector

Dual Laser InfraRed (IR) Thermometer

HT580 User Reference Guide. Version 1.0

INSTRUCTION MANUAL OVERVIEW Remote Meter: MT-5 Remote meter (Model MT-5) is available to connect with solar controller Tracer MPPT series.

Owner s Manual

INSTRUCTION MANUAL. NC-500 NETcat Pro Wiring Tester

GSM Door Phone System

Thermocouple Thermometer Models

Preface. Product Features

Dual Laser InfraRed (IR) Thermometer

Userʼs Manual. 7 Color LCD TV & Monitor V7000

User Manual of WT 493

G e t t i n g. Know your radio. 1 external power connector. on /off switch. aerial

MOUNTING AND OPERATING INSTRUCTIONS

QFP910. Water detector. Building Technologies. CE1N2732en Synco living

Transcription:

MULTI-FIELD EMF METER TM-190 User s Manual 1 B2TM1900001

Meun 1 Features... 4 2 Identifying Parts... 6 3 TFT description... 7 4 Measurement Procedures... 8 4.1 POWER ON/OFF Button:... 8 4.2 Reading Individual and Aggregated XYZ Axial Data:... 8 4.3 Data hold (HOLD):... 8 4.4 Menu Settings:... 9 4.4.1. Option Buttons: 10 4.4.2. Screen Brightness options: 10 4.4.3. Magnetic Unit: 10 4.4.4. RF Strength Unit: 11 4.4.5. Language: 12 4.4.6. Power Off Time: 13 4.4.7. Sound on/off: 14 4.4.8. Keys/Alarm Sound: 14 4.4.9. Keys Sound: 15 4.4.10. Alarm Sound: 15 2

4.4.11. Information: 16 5 Specifications... 17 5.1 Sensor type: LF Magnetic Fields (MF)... 17 5.2 Sensor type: LF Electric Fields... 17 5.3 Sensor type: RF Strength... 18 6 Battery replacement... 19 7 External USB power supply:... 20 8 Safety and maintenance standards... 20 9 End of life... 21 3

1 Features English Data hold (HOLD) Low battery indication: HIGH LOW Over load display OL. External USB Power Supply: Brightness options: low-middle-high Magnetic unit:gauss(mg) or. Tesla(uT) RF Strength Unit: (uw/m² ~mw/m²) (μw/cm²) (m V/m ~V/m) (ma/m) (dbm). Languages: English; Traditional Chinese; Simplified Chinese; Japanese; Español. Power Off Time:No; 1; 3; 5; 10; 15; 30. Factory default sets as 5. Settings can be changed by the user. is displayed on the screen after power off time is set. Keys/Alarm Sounds: On ; Off Low-Frequency EMF Readings: Individual and aggregated XYZ axial readings. RF Historical Records: Up to 20 groups. Information: Software version: V1.0 High-frequency EMF Readings: Please perform tests according to the indicated direction. 4

TM-190 English Electric field Measurement Precautions: Please perform tests according to the indicated direction. Please hold the meter at the bottom of the display, as shown in the figure below: Fig. 1 Electric Field measurement: Magnetic Fields Electric Field RF strength The Green zone 0~10.00mG 0~500V/m 0~0.99mW/m²;0~0.59V/m The Yellow zone 10.01~100mG 501~1000V/m 1~9.99mW/m²;0.6~1.9V/m The Red zone 101~2000mG >1001V/m >10mW/m²;>2V/m The color zones are for reference only electromagnetic safety reference standard international 國 際 的 Council Recommendation1999/519/EC 42V/m(4.75W/m²) 59V/m(9.25W/m²) international 國 際 的 ICNIRP Guidelines,April1998 42V/m(4.75W/m²) 59V/m(9.25W/m²) Austria 奧 地 利 ONORM S1120 49V/m(6.33W/m²) 61V/m(10W/m²) Belgium 比 利 時 Belgisch Staatsblad F.2001-1365 21V/m(1.18W/m²) 30V/m(2.31W/m²) Germang 德 國 26.Deutsche Verordnung 42V/m(4.75W/m²) 59V/m(9.25W/m²) italy 意 大 利 Decreto n.381,1998 20V/m(1W/m²) 20V/m(1W/m²) the netherlands 荷 蘭 Health Council 51V/m(6.92W/m²) 83V/m(18W/m²) switzerland 瑞 士 Verordnung 1999 4V/m(0.04W/m²) 6V/m(0.1W/m²) united states 美 國 IEEE C95.1 49V/m(6.33W/m²) 68V/m(12W/m²) china 中 國 Draft:National Quality Technology Monitoring Bureau 49V/m(6.33W/m²) 61V/m(10W/m²) japan 日 本 Radio-Radiadiation Protection Guidelines,1990 49V/m(6.33W/m²) 61V/m(10W/m²) 1W/m²=0.1mW/Cm²=100uW/Cm².1mW/m²=0.1uW/Cm² 5

2 Identifying Parts Fig. 2 Instrument description: 1. 2.4 240*320 resolution color TFT. 2. Power and Menu button 3. Hold and Enter button 4. Select and Down button 5. Mini USB power interface 6. Battery cover 6

3 TFT description 1 Data Hold indicator. 2 Auto power off indicator. 3 Buzzer indicator. 4 Battery indicator. 5 Connecting a USB power indicator. 6 Tesla(uT) or Gauss(mG) display. 7 Electric Field (V/m) display. 8 RF strength history histogram display. 9 RF strength digital (mv/m/ W/m²/μW/cm²/dB) display. 10 Menu key indication 11 Hold/ Enter key indicator 12 RF electronic field warning indicator: GOOD/NORMAL/WARNING. 13 LF electric field warning indicator: GOOD/NORMAL/WARNING. 14 Individual XYZ axial value of LF electromagnetic wave display 15 LF electromagnetic wave warning indicator: GOOD/NORMAL/WARNING 7

4 Measurement Procedures 4.1 POWER ON/OFF Button: Press button to power on. LCD display measurement screen.(see Fig. 3) Press button for 3 seconds to power off LCD display. 4.2 Reading Individual and Aggregated XYZ Axial Data: Direct the front section of the meter at the desired electromagnetic field for measurements. The meter simultaneously displays the electromagnetic field readings of individual and aggregated XYZ axes, where the aggregated calculation equation can be expressed as follows: Because of environment-related magnetic field factors, this electromagnetic field EMF meter may display a reading of under 0.50 mg prior to testing. This is caused by the magnetic noise in the environment, rather than meter failure. 4.3 Data hold (HOLD): Press the left button as to activate the HOLD function and hold the current readings at the upper left of the display. To release the held data, press the left button again. Press the middle button for 3 seconds to power off the meter. 8

4.4 Menu Settings: On the measurement screen: Press the middle button to enter the main menu, where 7 options can be selected, namely, Brightness, Magnetic unit, RF Strength Unit, Language, Power off, Sound, and Information. Press the right button to make the blue brick scroll down. Press the right button repeatedly, and the blue brick will cycle through the options. Press the left button to enter the selected option. Press the left button again to exit the selected option and return to the main menu. Press the middle button to return to the previous menu. 9

4.4.1. Option Buttons: Press the right button to scroll to and check the next check box. Press the right button repeatedly to cycle through the check boxes. Press the left button to exit to the main menu. Press the middle button to return to the previous setting menu. 4.4.2. Screen Brightness options: Following the operation procedures in 4.4, the Brightness setting comprises the following three options, namely, Low, Middle, and High. Under the sub-directory, use the option buttons to select and confirm the desired selection. Default: Middle 4.4.3. Magnetic Unit: Following the operation procedures in 4.4, the Magnetic Unit setting comprises the following two options, namely, Gauss/mG and Tesla/uT. Under the sub-directory, use the option buttons to select and confirm the desired selection. Default: mg 10

4.4.4. RF Strength Unit: Following the operation procedures in 4.4, the RF Strength Unit setting comprises the following five options, namely, uw/m²~mw/m², uw/cm², mv/m~v/m, ma/m, and dbm (files are automatically skipped within the selected unit). Under the sub-directory, use the option buttons to select and confirm the desired selection. Default: uv/m² ~ mw/m² 11

4.4.5. Language: Following the operation procedures in 4.4, the Language setting comprises the following five options, namely, English, Traditional Chinese, Simplified Chinese, Japanese, and Español (Spanish). Under the sub-directory, use the option buttons to select and confirm the desired selection. Default: English 12

4.4.6. Power Off Time: Following the operation procedures in 4.4, the Power Off setting comprises the following seven options, namely, NO, 1, 3, 5, 10, 15, and 30 (min). Under the sub-directory, use the option buttons to select and confirm the desired selection. Default: 5min 13

4.4.7. Sound on/off: Following the operation procedures in 4.4, the Sound setting comprises the following two options, namely, On and Off. Press the right button to scroll to and check the next check box. Press the right button to cycle thought he options. Press the left button to select the Enable setting and enter the Keys/Alarm Sound menu (Section 4.4.8). Press the left button to select the Disable setting and return to the main menu(fig. 3). Press the middle button to return to the measurement screen 4.4.8. Keys/Alarm Sound: Following the selection of the Enable option in the Sound settings menu, the Keys/Alarm Sound setting comprises the following two options, namely, Keys and Alarm. Press the right button to scroll to and check the check the next check box. Press the right button repeatedly to cycle through the options. Press the left button to enter the next options screen. 14

4.4.9. Keys Sound: Following the selection of the Keys option in the Keys/Alarm Sound settings menu, the Keys setting comprises 3 options, namely 1, 2, and 3. Press the right button to scroll to and check the next check box. Press the right button repeatedly to cycle through the options. Press the left button to exit to the main menu. Default: 3 4.4.10. Alarm Sound: Following the selection of the Alarm option in the Keys/Alarm Sound settings menu, the Alarm setting comprises 3 options, namely 1, 2, and 3. Press the right button to scroll to and check the next check box. Press the right button repeatedly to cycle through the options. Press the left button to exit to the main menu. Default: 3 15

4.4.11. Information: Following the operation procedures in 4.4, select the Information option to display the software version (V1.0). Press the left button to exit to the main menu. Press the middle button to return to the settings screen. 16

5 Specifications 5.1 Sensor type: LF Magnetic Fields (MF) The meter is equipped with three individual aerial sensors to measure EMFs. The overload indications can be displayed simultaneously on three axes (X, Y, Z): Range: 20/200/2000mG, 2/20/200µT. Resolution: 0.02/0.1/1 mg or 0.02/0.1/1 µt. Frequency response: 50/60 Hz Sensor: Triple Axis (X, Y, Z). Accuracy: ±(15%+100dgt). 5.2 Sensor type: LF Electric Fields Range: 50V/m to 2000V/m. Frequency response: 50/60Hz Accuracy: ± (7% + 50dgt). 17

5.3 Sensor type: RF Strength Frequency range:50mhz to 3.5GHz. Accuracy: ± 2dB at 2.45GHz Measurement units: uw/m²~mw/m²; μw/cm²; mv/m~v/m, ma/m, and dbm Specified measurement range: (0.02uW/m²to 554.6mW/m²) (0.02uW/cm²to 55.4uW/cm²)(36.1mV/mto14.46V/m) (0.02mA/m to 38.35mA/m)( -51dB to 16dBm) Display resolution: 0.02μW / m², 0.2μA / m, 0.2mV/m, m, 0.002μW/cm ², 2dB. Display: 4 digits Triple LCD display. Sample rate: 6 seconds per time. Battery life: Approximate 8 hours. Battery: 1.5V AAA Alkaline Battery*3. Audible Key tone alarm: Buzzer Operating temperature & humidity: 5 C to 40 C, below 80% RH. Storage temperature & humidity: -10 C to 60 C, below 70%. Weight: About 120g. Dimensions: 115(L)*60(W)*21(H) mm. 18

6 Battery replacement WARNING If the symbol appears on the screen, please replace the battery immediately Turn off the instrument. Open the battery covers and remove the battery. Take three new 1.5VAAA alkaline batteries, and install the batteries according to the polarity. Put back the battery cover. 19

7 External USB power supply: English External USB. Specifications: Voltage DC 4.8 ~ 5.2V current 500mA. A icon is displayed when an external USB power supply is connected to the meter. The meter determines connected USB cables to be antennas, and thus such cables should not exceed the top rim of the buttons during testing. If the cables exceed this limit, the readings of subsequent tests are considered invalid. 8 Safety and maintenance standards Do not operate around combustible gases or in damp environment. Operating altitude: below 2,000m. Operating environment: for indoor use, expose to pollution level II. This is a precision device. During use or storage, do not go beyond its spec. to prevent any possible damage or danger. Do not put this device in direct sunlight or where it is hot and/or damp. For long storage, remove the battery to prevent the battery from leaking and causing damage to the parts inside. Clean the device with a dry soft cloth. The use of wet cloths, liquid and water is prohibited. 20

9 End of life Caution This symbol indicates that equipment and its accessories shall be subject to a separate collection and correct disposal 21

Professional Electrical and Environment Test & Measurement Instruments: Battery Capacity/Impedance Tester, TACHO Meter, LED light meter, Temperature & Humidity meter, Infrared Thermometer, Sound level meter, Light meter, EMF meter, UV Light meter, RF meter, Hot wire Anemometer, CO meter, Anemometer, Lan cable tester, CO 2 meter, Solar power meter, Radiation meter, Clamp meter, Multimeter, Phase Rotation test, Digital Insulation tester. TENMARS ELECTRONICS CO., LTD 6F, 586, RUI GUANG ROAD, NEIHU, TAIPEI 114, TAIWAN. 22