Parallel Integrity Testing of Small Venting Filters. Application Note. Integrity Testing. turning science into solutions



Similar documents
croatia The New United States Pharmacopeia (USP) Chapter 41 It s easier than you think!

Process Analytical Equipment for Monitoring, Control and Cost Optimization of Inline Dilution Processes

fill-it Automated GMP Cell and Strain Banking System

ambr 250 Fully Automated Single-Use Bioreactor System

The New Practum. Unmatched reliability with the world-class weighing instrument

BIOSTAT B-DCU II Fully Flexible for Advanced Process Development

TECHNICAL BRIEF. Microfluor II Filter Cartridge Integrity Testing. Introduction. Forward flow integrity test. 1. Definition

arium Water Purification Systems

arium advance EDI Consistently high quality Type 2 water thanks to stateof-the-art Optimized water consumption automatic with ijust

LifeASSURE PFS Series Filter Cartridge Integrity Testing

Bioprocessing Media and Buffers Grow with Us

Pall in the Brewery (more value per hectolitre) DE Free Clarification FB1795

A 360 view on your packaging line. SPC Software and Product Inspection Solutions

Lenntech Tel Fax

METROLOGIC INSTRUMENTS, INC. MS1690 Focus Area Imaging Bar Code Scanner Supplemental Configuration Guide

Validation Guide. USTR 805j (5) Steam sterilization of Pall filter assemblies which utilize replaceable filter cartridges

Make the invisible visible! SENSORS WITH EXCELLENT BACKGROUND SUPPRESSION

Application Note. USD 2995 (a) High Throughput Regeneration Study on MEP HyperCel Mixed-Mode Sorbent on ScreenExpert RoboColumns u

GLOBAL DATA CENTER SPACE 2013

Application Note USTR 805. Steam Sterilization of Pall Filter Assemblies Utilizing Replaceable Filter Cartridges

A 360 view on your packaging line. SPC Software and Product Inspection Solutions

FEATURES PRODUCT SERIES IP5000/IP5100 HIGH PERFORMANCE POSITIONER COMPACT AND LIGHTWEIGHT RESISTANT TO HOSTILE ENVIRONMENTS DESIGNED TO IP55, NEMA 4

Product Summary. KLIMA 1 Catalogue KLIMA 2 Catalogue FILTER Catalogue. The art of handling air. Special leaflet SP/1/EN/7

Remote Desktop Connection

SST 2. Soft starting tool 2. Instruction manual

GLOBAL DATA CENTER INVESTMENT 2013

Urine Protein Concentration with Vivaspin Concentrators

Unfolding your potential. Discovering opportunities for your future. Transforming knowledge into results. Sartorius Scholarship

UniFlux 10: hollow fiber conversion kit ( ) installation instruction

CERTIFICATE ISO/TS 16949:2009. STMicroelectronics Tours. DEKRA Certification GmbH certifies that the company

USA. Mexico. South America. Australia. Austria. Bahrain. Belgium. Bulgaria. Canada


Gilbert Dupont Healthcare Conference

Durapore. High Throughput Flow Rates. Durapore 0.2 µm hydrophilic

PM 2 GRUNDFOS INSTRUCTIONS

IWAKI MAGNETIC DRIVE PUMPS MDM. Patent & Pat.Pend. JAPAN / U.S.A. / EU / CHINA / TAIWAN

CAT.ES120-4 A. Precision Clean Regulator. Series SRP. High precision, low flow consumption stainless steel regulator

Get the benefits of Norgren s unique range of Online services

MTA1 CAN, M1 10Prog CAN, AT1CAN, AT1 CoarseFine CAN, M1, AT1, AT1 CoarseFine, RA 12, RA 23, RA T1, FS 002 CAN, FS 002

MOLECULAR DRAG PUMPS MDP SERIES

Regional Strategies 82/90

TSI BIOTRAK REAL-TIME VIABLE PARTICLE COUNTER FACILITY MONITORING SYSTEMS

SP/1/EN/5. Product Summary. KLIMA 1 Catalogue KLIMA 2 Catalogue FILTER Catalogue. The art of handling air

We create, plan, buy & monitor international communication campaigns since 1993.

Tower Field Service Maintenance, Revamps and Installation

Using SPSS for item analysis

INVOICE MAILING ADDRESS

Building a Global Internet Company: Driving Traffic to Your Site. Benjamin Edelman Harvard Business School

Acrodose PL System. Enhanced Patient Safety. A New Platform for Pre-storage Pooling and Testing of Leukoreduced Whole Blood Derived Platelets

LifeASSURE PFS. Series Capsules & Cartridges Sterilising Grade PTFE Membrane Filters. 3M Purification. Product brochure

WHITE PAPER SIX ESSENTIAL CONSIDERATIONS WHEN CHOOSING A FIELD SERVICE SOFTWARE SOLUTION

ENrich SEC 70 ENrich SEC 650 High-Resolution Size Exclusion Columns Instruction Manual

State or Jurisdiction of Incorporation. Companies Listed by Country. Subsidiaries of Hertz Global Holdings, Inc. A. U.S. and Countries Outside Europe

IWAKI MAGNETIC DRIVE PUMPS MDM. Patent JAPAN / U.S.A. / TAIWAN / EU / CHINA

skills mismatches & finding the right talent incl. quarterly mobility, confidence & job satisfaction

Accuracy counts! SENSORS WITH ANALOG OUTPUT

Proton Therapy System A NEW WAY TO DO WHAT YOU DO BEST FIGHT CANCER

TUBING LEADER IN FLUID MANAGEMENT

How To Buy Eclipse Premium

2012 HAYS SALARY GUIDE SHARING OUR EXPERTISE. Salary and recruiting trends across Asia

Study Abroad Mark Conversion. Conversion Narratives

Missing data: the hidden problem

FedEx is the preferred and primary courier company for BP small package, parcel and express envelope (up to 150 lbs.) requirements worldwide.

TR40 Sterilizing Filtration of Gases A comparison with TR26 Sterilizing Filtration of Liquids

Second Quarter and First Half 2015 Trading Update

Installation Guide E Dielectric Probe Kit 85071E Materials Measurement Software

How To Get A New Phone System For Your Business

VAT Guidelines for Tooling. Volvo Group VAT guidelines for Vendor Tooling

PLEUR EVAC CHEST DRAINAGE SYSTEMS. Great Innovations to Enhance Chest Drainage

Assembly and Installation Procedures

Supplies 1. Toner cartridges. Printing. Using color. Paper handling. Maintenance. Troubleshooting. Administration. Index

A new ranking of the world s most innovative countries: Notes on methodology. An Economist Intelligence Unit report Sponsored by Cisco

2015 Growth in data center employment continues but the workforce is changing

Lenntech Tel Fax

Batch coater For exceptional product quality

Colour Measurement Solutions for the Food Industry. Trusted by Over 70% of the Top 100 Global Food and Drink Companies*

E-Seminar. E-Commerce Internet Business Solution Seminar

Sterile ReadyToProcess Hollow Fiber Cartridges Instructions for Use

Foreign Taxes Paid and Foreign Source Income INTECH Global Income Managed Volatility Fund

Global Real Estate Outlook

Analysis of Chlorine, Bromine and Iodine in Water using ICP-AES

Thermo Scientific Barnstead TII Pure Water Systems. Pure water. Pure research. Total confidence.

Manual tensioning and sealing Pneumatic tensioning and sealing

OTRS AG Enjoy your Service Management

advanced hot runner temperature control.

Ethernet QoS Test Multi-stream Network Quality Evaluation

Dow Liquid Separations DOWEX MARATHON MSA. Ion Exchange Resin. Engineering Information

The Path Forward. International Women s Day 2012 Global Research Results

Image Lab Software for the GS-900 Densitometer

Agilent 4339B/4349B High Resistance Meters

Guide. Axis Webinar. User guide

METROLOGIC INSTRUMENTS, INC. USB Addendum for the IS4220 Programming Guide (MLPN x)

Diafiltration: A Fast, Efficient Method for Desalting, or Buffer Exchange of Biological Samples

OTHER USERS - YOU SHOULD CAREFULLY READ THE FOLLOWING TERMS. YOUR INSTALLATION OF THE PROGRAM INDICATES YOUR ACCEPTANCE OF THESE LICENSE TERMS.

Free Cooling for Data Centers

The Right Tool at the Right Time. Gängtapp och borrset. enligt DIN- och ISO-standard

Global Investing 2013 Morningstar. All Rights Reserved. 3/1/2013

Sterile Acrodisc Syringe Filters

Transcription:

Parallel Integrity Testing of Small Venting Filters Application Note Integrity Testing turning science into solutions

Dr. Jens Meyer Product Manager Gas Filtration & Integrity Testing Figure 1: Test arrangement for parallel integrity testing of 10 Midisart venting filters. Introduction Sterilizing grade venting filters are used to avoid the potential risk of air-borne germs contaminating containers like fermentors or cell-culture vessels. Sterilizing grade filtration can only be guaranteed when the filters used are tested for integrity. Therefore, such filters are routinely tested by the bubble point or similar tests. Depending on the program settings and the actual bubble point (BP), it can easily take 10 20 min to perform one such test. When a large number of filters are used and tested every day, it makes sense to think about how to make the test procedure more efficient without increasing the risk of overlooking defective filters. This article describes a method by which Midisart venting filters can be tested efficiently by means of parallel testing. This parallel testing method drastically reduces the time required for testing, in turn yielding a clear economic benefit for users without compromising safety. Method How to Perform Bubble Point Tests Using the Parallel Method Small venting filters of the type Midisart 2000 with a pore size of 0.2 μm and an effective filtration area of 20 cm 2 were used for this investigation. To prove their ability for detecting a single defective filter within an array of 10 filters in a parallel arrangement, one filter of pore size 0.2 μm was replaced with a filter with pore size 0.45 μm. The theory behind this set up was that, although the 0.45 μm filter was perfectly intact and within specification for 0.45 μm filters, it should not pass the integrity test run on bubble point limit values for 0.2 μm filters. If this theory applied, the question would then be to determine if it is possible for an automatic integrity tester to reliably detect the out-of-specification Midisart between the 0.2 μm standard filters. An essential prerequisite for performing bubble point tests is that the membrane is wetted completely with a suitable wetting liquid. Because the PTFE membrane of the Midisart filters is extremely hydrophobic and not spontaneously wettable by water, a 60% mixture of isopropyl alcohol (IPA)- water-mixture was used for wetting the membranes. To flush each filter with 20 ml of 60% IPA, a disposable syringe was used to apply the wetting solution in the direction of filtration. Because the testing procedure forced wetting liquid out of the pores, any filters used for repeated testing were re-wetted in the same manner as described above to avoid any effect on the test results. In the first step, the filters were wetted and then tested individually using the Sartocheck 4 automatic integrity tester. The test results were documented electronically and additionally printed out on paper. In the second step, the same filters were mounted on the Midisart manifold (figure 1) containing an array of 10 Midisarts and the manifold was subjected to a parallel bubble point test using the same test unit. The results were documented. 2

To show that it is possible to detect a single defective filter amongst 9 others, one Midisart 2000 filter with pore size 0.2 μm (min BP = 1.4 bar) was replaced with a Midisart 2000 filter with pore size of 0.45 μm (min BP = 0.9 bar) as described above. Then, the complete manifold with 9 intact plus one assumedly defective filter was tested. Although the 0.45 μm filter was intact, it should theoretically be identified as defective within the specification for the 0.2 μm filters (BP < BP min ). Results An average bubble point of 1.69±0.025 bar was found for the 0.2 μm Midisart filter, while the 0.45 μm version had a significantly lower BP of 1.23 bar (figure 2). This meant that the 0.45 μm filter failed the test as soon as the BP limit (BP min) for the 0.2 μm filter was used as test criterion. Individual Tests The stabilization time was set to 5 min and a minimum BP of 1.4 bar was programmed. 70 60 BP min Before testing all filters separately as described above, the test series was started with a leakage test to prove the validity of the complete test setup. For this purpose, all valves of the test manifold were closed and a pressure hold test (P = 2 bar, t = 5 min.) was run with the integrity tester Sartocheck 4. The pressure was kept pretty stable during the test without any signs of leakage. Flow [ml/min] 50 40 0,45 µm 0,2 µm 30 20 10 0 1000 1100 1200 1300 1400 1500 1600 1700 1800 Pressure [mbar] Figure 2: Test results of the bubble point tests for individual Midisart filters. Each curve represents the measurement of a single filter. 10 Midisart 2000 filters with a pore size of 0.2 μm (black curves) and one Midisart with a pore size of 0.45 μm (red curve) were tested. 3

The parallel test of the 10 "intact Midisarts resulted in a BP all of 1.57 bar (figure 3). This value correlate nicely with the BP values measured for the individual filters. The measured BP of the parallel test was slightly lower compared to the BP of individual tests due to the fact that the flow through the 10 filters is higher which then consequently leads to an earlier detection of the BP criterion. The test was classified as test passed and therefore all 10 filters showed integrity. In the next step where one "intact Midisart was replaced with the "defective filter (0.45 μm) and the array of the 10 filters (9 intact plus 1 defective with a low BP) was subjected to a BP test at the identical test parameter settings, the test resulted in a BP of 1.23 bar and the test was classified as test failed (figure 3). The BP value of all 10 filters was clearly defined by the filter with the lowest BP (1.23 bar) which was the so-called "defective" one. This meant that the defective filter was successfully detected when 10 filters were measured in parallel. To confirm this result, the defective filter was pneumatically decoupled by closing the connected valve and the remaining 9 intact Midisarts were retested after re-wetting. This test resulted in a BP of 1.57 bar, i.e. it was identical to the test result obtained when all 10 "intact" filters were tested. Parallel Tests Flow [ml/min] 70 60 50 40 30 20 10 1 defective + 9 intact i t t "Test Failed" BP = 1,23 bar 10 intact "Test Passed" BP = 1,57 bar 0 BP min. 900 1.100 1.300 1.500 1.700 Pressure [mbar] 10 intact 9 intact+1 defective 1 defective 9 intact Figure 3: Test results of parallel bubble point tests of 10 filters arranged on the Midisart test manifold. Substituting one intact filter for a "defective" one (0.45 μm pore size) led to a clear shift in the bubblepoint curve and finally resulted in a failed test. The filter with the lowest BP also defined the BP when multiple filters were tested in parallel. Therefore, a single defective filter can be reliably detected within a multiple testing manifold. 4

Discussion The Bubble Point Test The bubble point is defined as the pressure at which the wetting liquid is forced out of the pores, thereby creating bubbles. By increasing the pressure on the upstream side, the differential pressure increases and finally overcomes the capillary forces to consequently press water out of the pores of the filter. Wetted membrane a) Ambient pressure gas molecules b) Pressurized Air (P<BP) c) Pressurized Air (P BP) diffusion diffusion diffusion + bulk flow Figure 4: When a differential pressure is applied across a completely wetted membrane, the pores are blocked and only low quantities of gas molecules have the chance to pass the membrane by diffusion. When the differential pressure exceeds the bubble point, the wetting liquid is forced out of the biggest pores, leading to an over-proportional increase of air flow. This behaviour is used for identifying the BP of a membrane. Below the bubble point pressure, only diffusive flow through the wetted pores takes place. In that situation the amount of diffusive flow is relatively low, and a linear relationship exists between test pressure and air flow rate. When the test pressure is increased incrementally to the bubble point, the air flow starts to increase overproportionally because diffusive flow occurs at this point in parallel with bulk flow through opened pores. This bulk flow is much bigger than the diffusive flow and can be used to detect the bubble point. In principle, the automatic integrity tester checks the air flow by measuring the pressure decay in the filter housing on the upstream side of the filter. The test pressure is increased in increments of 50 mbar and the air flow rate is measured for each step. The resolution of the bubble point measurement is limited by the size of the increment (±50 mbar) but can also be adjusted when higher accuracy is required or test time should be shortened. The test device determines the point of over-proportional increase of the air flow using internal algorithms. This correlates with the point where the first pores open and enhanced flow starts. The integrity tester uses this pressure as the bubble point. 5

The bubble point therefore reflects the pore size of the largest pores within the membrane, namely because the pores with the largest pore diameter offer the lowest capillary forces and the liquid is removed more easily than through smaller-diameter pores. This fact makes sense because exactly those large pores offer a risk for micro-organisms to pass the membrane, which consequently would lead to product contamination. It should be mentioned here that the bubble point per se does not tell anything about the retention capabilities of the membrane, but is only a robust physical test. To determine the retention capability of a filter, sophisticated microbiological tests must be performed and correlated with the results of the integrity tests. Such tests are performed by the filter manufacturers during filter validation and for the purpose of quality checks. Filters have to pass the bacterial challenge test (BCT) which means they must be able to produce a sterile filtrate after filtering a test solution containing 10 7 bacteria (Brevundimonas diminuta) per cm 2 filter area (HIMA document No. 3, VoP. 4, 1982). The limit value (BP min) is defined when correlating the test result of the BCT (test passed or failed) with the BP of the same filter and adding a specific safety margin. As soon as the BP of a filter drops below the limit value (BP min), sterile filtrate or sterile air filtration cannot be guaranteed. Consequently, such filters may not be used in pharmaceutical production process. The facts discussed above underline the critical importance of filter integrity testing within biopharmaceutical production processes. Therefore, it is necessary to reliably detect defective filters within a multiple-filter arrangement and parallel integrity testing. Bulk Flow Flow Diffusive Flow (linear) Bubble Point (non-linearity) Pressure P BP Figure 5: Air flow curve plotted for a wetted membrane during a standard bubble point test. At the bubble point, the curve starts to be non-linear due to the enhanced air flow through opened pores. 6

Identification of Defective Filters Obviously, a failed filter integrity test does not identify which of the parallel tested filters is the defective one. Consequently, all 10 filters have to be tested individually to achieve safety. The Midisart test manifold was designed to allow a different approach. Short tubes can be connected to the hose barbs of the filters and the other end can be hung in a water bath. The bubble point test is started and the test pressure is reached; the diffusion-driven air flowing through the wetted membrane causes the air bubbles to come out of the tube slowly. As illustrated above, the bubble point is characterized by a disproportionate increase in air flow. This sudden increase in flow can be visualized by a sudden increase in air bubbling out of the tube. A defective filter reaches the BP earlier and can be identified simply by observing the air bubbles that leave the different tubes. As soon as the defective filter is identified, it can be pneumatically decoupled from the manifold by closing the valve and the remaining 9 filters can be tested afterwards. The parallel procedure avoids all 10 filters having to be tested individually. Conclusion In conclusion, the data presented above clearly show that a single defective filter reliably leads to a failed integrity test when tested in a multiple arrangement together with 9 intact filters. The relatively small filtration area of 20 cm 2 produces a low diffusion rate for the single elements. In this situation, the masking effects common with larger (pleated) filter elements play a negligible role. When more than one filter is tested for integrity, the filter with the lowest bubble point determines the BP of the multiple filter arrangement. This observation underlines the safety of parallel testing such small filters and proves that a defective filter will lead to a failed test. The time required for the testing procedure can thereby be reduced by 90%. This allows more filters to be tested in a given time frame which generates an economic benefit for users. In this context, it is important to note that a failed test does not automatically mean that a filter is really defective. When filters repeatedly fail integrity testing, the correct wetting of the membrane should be checked. A membrane that is not perfectly wetted will definitely fail the test although the membrane itself is functioning properly within its sterilizing grade. In such a case, the wetting procedure should be improved and the test repeated. 7

Sales and Service Contacts For further contacts, visit www.sartorius-stedim.com Europe America Asia Pacific Germany Sartorius Stedim Biotech GmbH August-Spindler-Strasse 11 37079 Goettingen Phone +49.551.308.0 Fax +49.551.308.3289 www.sartorius-stedim.com Sartorius Stedim Systems GmbH Schwarzenberger Weg 73 79 34212 Melsungen Phone +49.5661.71.3400 Fax +49.5661.71.3702 www.sartorius-stedim.com France Sartorius Stedim Biotech S.A. Z.I. des Paluds Avenue de Jouques BP 1051 13781 Aubagne Cedex Phone +33.442.845600 Fax +33.442.845619 Sartorius Stedim France SAS ZI des Paluds Avenue de Jouques CS 71058 13781 Aubagne Cedex Phone +33.442.845600 Fax +33.442.846545 Austria Sartorius Stedim Austria GmbH Franzosengraben 12 A-1030 Vienna Phone +43.1.7965763.18 Fax +43.1.796576344 Belgium Sartorius Stedim Belgium N.V. Leuvensesteenweg, 248/B 1800 Vilvoorde Phone +32.2.756.06.80 Fax +32.2.756.06.81 Denmark Sartorius Stedim Nordic A/S Hoerskaetten 6D, 1. DK-2630 Taastrup Phone +45.7023.4400 Fax +45.4630.4030 Italy Sartorius Stedim Italy S.p.A. Via dell Antella, 76/A 50012 Antella-Bagno a Ripoli (FI) Phone +39.055.63.40.41 Fax +39.055.63.40.526 Netherlands Sartorius Stedim Netherlands B.V. Edisonbaan 24 3439 MN Nieuwegein Phone +31.30.6025080 Fax +31.30.6025099 Spain Sartorius Stedim Spain SA C/Isabel Colbrand 10 12, Planta 4, Oficina 121 Polígono Industrial de Fuencarral 28050 Madrid Phone +34.91.3586102 Fax +34.91.3588804 Switzerland Sartorius Stedim Switzerland GmbH Lerzenstrasse 21 8953 Dietikon Phone +41.44.741.05.00 Fax +41.44.741.05.09 U.K. Sartorius Stedim UK Limited Longmead Business Park Blenheim Road, Epsom Surrey KT19 9 QQ Phone +44.1372.737159 Fax +44.1372.726171 USA Sartorius Stedim North America Inc. 5 Orville Drive Bohemia, NY 11716 Toll-Free +1.800.368.7178 Fax +1.631.254.4253 Sartorius Stedim SUS Inc. 1910 Mark Court Concord, CA 94520 Phone +1.925.689.6650 Toll Free +1.800.914.6644 Fax +1.925.689.6988 Sartorius Stedim Systems Inc. 201 South Ingram Mill Road Springfield, MO 65802 Phone +1.417.873.9636 Fax +1.417.873.9275 Argentina Sartorius Argentina S.A. Int. A. Avalos 4251 B1605ECS Munro Buenos Aires Phone +54.11.4721.0505 Fax +54.11.4762.2333 Brazil Sartorius do Brasil Ltda Av. Dom Pedro I, 241 Bairro Vila Pires Santo André São Paulo Cep 09110-001 Phone +55.11.4451.6226 Fax +55.11.4451.4369 Mexico Sartorius de México S.A. de C.V. Circuito Circunvalación Poniente No. 149 Ciudad Satélite 53100 Naucalpan, Estado de México Phone +52.5555.62.1102 Fax +52.5555.62.2942 China Sartorius Stedim Beijing Representative Office No. 33, Yu an Road, Airport Industrial Zone B, Shunyi District Beijing 101300 Phone +86.10.80426516 Fax +86.10.80426580 Sartorius Stedim Shanghai Represantative Office Room 618, Tower 1, German Centre, Shanghai, PRC., 201203 Phone +86.21.28986393 Fax +86.21.28986392.11 Sartorius Stedim Guangzhou Office Room 704, Broadway Plaza, No. 233 234 Dong Feng West Road Guangzhou 510180 Phone +86.20.8351.7921 Fax +86.20.8351.7931 India Sartorius Stedim India Pvt. Ltd. 10, 6th Main, 3rd Phase Peenya KIADB Industrial Area Bangalore 560 058 Phone +91.80.2839.1963 0461 Fax +91.80.2839.8262 Japan Sartorius Stedim Japan K.K. KY Building, 8 11 Kita Shinagawa 1-chome Shinagawa-ku Tokyo 140-0001 Phone +81.3.3740.5407 Fax +81.3.3740.5406 Malaysia Sartorius Stedim Malaysia Sdn. Bhd. Lot L3-E-3B, Enterprise 4 Technology Park Malaysia Bukit Jalil 57000 Kuala Lumpur Phone +60.3.8996.0622 Fax +60.3.8996.0755 Singapore Sartorius Stedim Singapore Pte. Ltd. 10, Science Park Road, The Alpha #02-25, Singapore Science Park 2 Singapore 117684 Phone +65.6872.3966 Fax +65.6778.2494 Australia Sartorius Stedim Australia Pty. Ltd. Unit 5, 7-11 Rodeo Drive Dandenong South Vic 3175 Phone +61.3.8762.1800 Fax +61.3.8762.1828 Specifications subject to change without notice. Printed in Germany on paper that has been bleached without any use of chlorine. W G. Publication No.: SPI4005-e09051 Order No.: 85034-538-32 Ver. 05 2009