APPLICATIONS FOR MOTOR CURRENT SIGNATURE ANALYSIS



Similar documents
SYNCHRONOUS MACHINE TESTING WITH MOTOR CIRCUIT ANALYSIS INSTRUMENTATION

Single and Three Phase Transformer Testing Using Static Motor Circuit Analysis Techniques

Evaluating Induction Motor Rotor Bars with Electrical Signature Analysis

Rotating Machinery Diagnostics & Instrumentation Solutions for Maintenance That Matters

VARIABLE FREQUENCY DRIVES THEORY, APPLICATION, AND TROUBLESHOOTING

Electric Motor Repair: Research Project on Soft Foot

AC-Synchronous Generator

Chapter 4.5: Electric Motors, Variable Speed Drives

Line Reactors and AC Drives

Motor Current Signature Analysis and its Applications in Induction Motor Fault Diagnosis

Machine diagnosis: Quick and easy through FFT analysis

Variable Frequency Drives - a Comparison of VSI versus LCI Systems

WIND TURBINE TECHNOLOGY

THIS paper reports some results of a research, which aims to investigate the

2. A conductor of length 2m moves at 4m/s at 30 to a uniform magnetic field of 0.1T. Which one of the following gives the e.m.f. generated?

SECTION 4 ELECTRIC MOTORS UNIT 17: TYPES OF ELECTRIC MOTORS

Simulation and Analysis of PWM Inverter Fed Induction Motor Drive

Induction Motor Testing and Evaluation

Unit 96: Marine Propulsion Power Plant

..OR How To Protect your 3-Phase Equipment Investment with 3-Phase Monitors from Time Mark...

Principles of Adjustable Frequency Drives

Case Studies on Paper Machine Vibration Problems

Predictive Maintenance

Diode Applications. by Kenneth A. Kuhn Sept. 1, This note illustrates some common applications of diodes.

CAT AVR V2.3. Instruction Manual. Voltage regulator for generators. March 2008

Specifying a Variable Frequency Drive s

Pump Vibration Analysis

C Standard AC Motors

AC generator theory. Resources and methods for learning about these subjects (list a few here, in preparation for your research):

Vibration Analysis Services. FES Systems Inc. 1

Transformer circuit calculations

ALERT AUTOMATED DIAGNOSTIC SOFTWARE

LOW COST MOTOR PROTECTION FILTERS FOR PWM DRIVE APPLICATIONS STOPS MOTOR DAMAGE

SYNCHRONOUS MACHINES

DC MOTOR ANALYSIS & TROUBLESHOOTING

Documenting Results to Validate Energy Savings Projects: Case Study of Direct Drive Cooling Tower Installations: Before and After

PeakVue Analysis for Antifriction Bearing Fault Detection

Modelling, Simulation and Performance Analysis of A Variable Frequency Drive in Speed Control Of Induction Motor

GenTech Practice Questions

Paralleling Power Sources Which Share a Common Neutral

Case Studies in On-Line Measurement of PD in Motors Fed by Voltage Source PWM Drives

Lab 8: DC generators: shunt, series, and compounded.

ELECTRICAL ENGINEERING Vol. III - Induction Motor and Self-Excited Induction Generator - Tze-Fun Chan

Generator Stator Protection, under/over voltage, under /over frequency and unbalanced loading. Ramandeep Kaur Aujla S.NO

Single-Phase AC Synchronous Generator

Unit 33 Three-Phase Motors

Introduction. Upon completion of Basics of AC Motors you should be able to:

Basics of Electricity

Solving VFD-sourced Bearing Current Problems in AC Motors.

Voltage Unbalance and Motors

Modeling and Simulation of a Novel Switched Reluctance Motor Drive System with Power Factor Improvement

Product Data Bulletin

32VFD Variable Frequency Drives for Centrifugal Chillers

Transformerless UPS systems and the 9900 By: John Steele, EIT Engineering Manager

Offshore Platform Powered With New Electrical Motor Drive System

Increase System Efficiency with Condition Monitoring. Embedded Control and Monitoring Summit National Instruments

Induction Motor Theory

Unidrive M Energy Savings

VARIABLE FREQUENCY DRIVES. Energy Efficiency Reference Guide

Vibration Monitoring: Envelope Signal Processing

AND8008/D. Solid State Control Solutions for Three Phase 1 HP Motor APPLICATION NOTE

Motor Fundamentals. DC Motor

Vibration analysis: what does it mean?

Phase-Control Alternatives for Single-Phase AC Motors Offer Smart, Low-Cost, Solutions Abstract INTRODUCTION

E&I MAINTENANCE ENTRY TEST ENABLING OBJECTIVES. DESCRIBE hazards and precautions taken to avoid injury in the workplace.

Multimeter measurements on variable frequency drives using the new Fluke 289 DMM

SAFETY PRECAUTIONS AND INSTRUCTIONS FOR USE OF TECHNICAL INFORMATION

Practical On-Line Vibration Monitoring for Papermachines

Equipment: Power Supply, DAI, Wound rotor induction motor (8231), Electrodynamometer (8960), timing belt.

What Is Regeneration?

Automatic Voltage Regulator User s Manual

AC Induction Motor Slip What It Is And How To Minimize It

PowerFlex Dynamic Braking Resistor Calculator

MCM; An Inexpensive, Simple to Use Model Based Condition Monitoring Technology

1587/1577. Insulation Multimeters. Technical Data. Two powerful tools in one.

Fundamentals of Inverter Fed Motors

Harmonics and Noise in Photovoltaic (PV) Inverter and the Mitigation Strategies

How To Improve A Variable Frequency Drive

Diesel Engine Driven Generators Page 1 of 6

Number 1 in efficiency

Synchronous motor. Type. Non-excited motors

PacifiCorp Original Sheet No. 476 FERC Electric Tariff, Substitute 6 th Rev Volume No. 11 APPENDIX 2 TO SGIP

1 Temperature Derating Guide

FREQUENCY CONTROLLED AC MOTOR DRIVE

DHANALAKSHMI COLLEGE OF ENGINEERING DEPARTMENT OF ELECTRICAL AND ELECTRONICS ENGINEERING EE ELECTRICAL MACHINES II UNIT-I SYNCHRONOUS GENERATOR

EVANS ENTErprises, Inc.

Troubleshooting accelerometer installations

DIRECT CURRENT GENERATORS

PM734F - Technical Data Sheet Winding 28

Once you know the volume of air and the static pressure of the system to be cooled, you can determine the fan specifications for your product.

PI734D - Technical Data Sheet

PI734B - Technical Data Sheet

Circuit Breaker LTB D with Motor Drive. Motor Drive. ABB PP/H/HV - Page 1. Ed

Effective: September 10, 2006 Vermont Attachment 1 to Rule Public Service Board Page 1 of 6

AC Electric Motors best practice

INSTALLATION AND MAINTENANCE INSTRUCTIONS FOR THREE PHASE INDUCTION MOTORS

13 common causes of motor failure

APPLICATION GUIDELINE FOR ELECTRIC MOTOR DRIVE EQUIPMENT FOR NATURAL GAS COMPRESSORS

Permanent Magnet Technology within Direct Drive Cooling Tower Motors Creates System Energy Savings

Transcription:

APPLICATIONS FOR MOTOR CURRENT SIGNATURE ANALYSIS An ALL-TEST Pro White Paper By Howard W Penrose, Ph.D. General Manager ALL-TEST Pro A Division of BJM Corp 123 Spencer Plain Rd Old Saybrook, CT 06475 Ph: 860 399-5937 Fax: 860 399-3180 Email: hpenrose@bjmcorp.com 2004 ALL-TEST Pro $25

APPLICATIONS FOR MOTOR CURRENT SIGNATURE ANALYSIS Howard W Penrose, Ph.D. General Manager, ALL-TEST Pro A Division of BJM Corp Old Saybrook, Connecticut Introduction Motor Diagnostic technologies have become even more prevalent through the 1990 s and into the new century. The technologies include both Motor Circuit Analysis (MCA) and Motor Current Signature Analysis (MCSA) applied to both energized and de-energized electric motor systems. The applications appear to be almost endless. The systems included in this paper are the ALL- TEST IV PRO 2000 motor circuit analyzer, the ALL-TEST PRO OL motor current signature analyzer, EMCAT motor management software, Power System Manager software, and ATPOL MCSA software. The ALL-TEST PRO MD kit includes the integration of all of these systems in addition to the US Department of Energy s MotorMaster Plus software. The purpose of this paper is to emphasis the MCSA application of the ALL-TEST PRO MD system which maintains the following: MCA readings of resistance, impedance, inductance, phase angle, current/ frequency response and insulation to ground (MegOhm) testing. MCSA capabilities of voltage and current demodulation, including FFT analysis to 5 khz. Automated analysis and trending capabilities for both MCA and MCSA through software. Full Power Quality datalogging and analysis including instantaneous three phase event capture. The examples found within this paper include many of the potential applications available through the implementation of Motor Diagnostic technologies. Rotor Bar Testing The fundamental purpose behind the original development of MCSA technology was the detection of rotor bar faults. Rotor bars are difficult to assess using traditional test methods, including vibration analysis. It was determined that a method using current could be used to evaluate the condition of the rotor bars. The basic rule is simple: Pole pass frequency sidebands around the fundamental line frequency, when the motor is under load, indicate problems with the rotor. The standard rule has been determined that rotor bar issues are serious when the sideband peaks approach to within 35 db of the line frequency peak. Figure 1: Rotor Bar Frequencies The example in Figure 1 shows sidebands at about -40 db from the peak line frequency. This would indicate at least one fractured rotor bar in this 500 HP, 4160 Volt motor on a compressor. Figure 2 is an example of one of two possible scenarios: Casting voids in an aluminum rotor. Soft tooth (or teeth) in a geared application. 2004 ALL-TEST Pro Page 1 of 6 hpenrose@bjmcorp.com

Figure 2: Casting Void or Soft Gear Tooth Figure 4: Stator Mechanical Fault Using higher frequency demodulated voltage and current FFT s, issues such as dynamic and static eccentricity, loose rotor bars and other rotor-related faults can be detected. Figure 3: Rotor Rub at No Load The data in Figure 3 relates to a 7.5 horsepower, 1800 RPM, submersible pump tested dry at no load. The rotor was rubbing slightly against the stator core which was identified as static and dynamic eccentricity with multiple current peaks as shown. As you will note in Figure 4, peaks are identified in current, but do not show in the voltage FFT. This indicates that mechanical faults exist. As they relate to the running speed and the number of stator slots, it is a mechanical fault related to the windings. Several other current-only peaks exist, indicating load-related faults, in this case, most likely a gearbox problem (note that this is the high-frequency data related to Figure 2). Figure 5: Mechanical Unbalance Induction Motor Testing Single and three phase motors can be evaluated using a combination of demodulated voltage and current. One particular rule, and strength, of a combination of voltage and current, is that if the peaks show in voltage and current, the fault is electrical in nature, if the peak shows in current, but not voltage then the problem is mechanical in nature. One other advantage to evaluating systems with MCSA is that you can detect power supply and load-related faults. The motor shown in Figure 5 had a mechanical unbalance. The signature shows up as a twice line frequency (LF), four times line frequency then twice line frequency pattern. In this case, rotor bars times running speed with LF sidebands then the remaining pattern appears. 2004 ALL-TEST Pro Page 2 of 6 hpenrose@bjmcorp.com

DC Motor Testing Figure 8: Alternator Dynamic Eccentricity DC motors are evaluated in a similar way as vibration. As a matter of fact, the signatures are the same in vibration as in MCSA. The DC voltage and current are taken from the armature circuit. Figure 6: DC Drive Fault The alternator being tested showed an increase to eccentricity over a 40 minute test run, rotating field faults and some electrical fault signatures. This information was coupled with MCA data which indicated a winding short, a cable short and a significant drop in insulation resistance over the short part-load run. In the case of Figure 6, multiple harmonics of line frequency plus multiple harmonics of the number of power electronics (SCR s) times line frequency (360 Hz, in this case), indicates an SCR fault or loose connection. This can be confirmed by viewing the voltage and frequency ripple in the low frequency data. Synchronous Alternator Testing The alternator was a 475 kw, 480 Vac alternator which required three parallel cables per phase. There are a number of options with the ATPOL system for larger cables. However, in a pinch, one of each of the three cables of each phase was used, so the current values were roughly 1/3 rd. Figure 9: Current Connection for Alternator Synchronous alternators can also be evaluated quickly and simply using voltage and current demodulated current. In the case of the following example, an alternator tripped on high temperature. Both MCA and MCSA were used to evaluate the system. Figure 7: MCSA Data on Synchronous Alternator (Low Freq) Variable Frequency Drives Variable frequency drives have been a challenge for a number of MCSA systems. In the case of the ATPOL, however, this is not a problem. The output voltage and current signals can be viewed (Figure 10). 2004 ALL-TEST Pro Page 3 of 6 hpenrose@bjmcorp.com

Figure 10: VFD Voltage and Current Waveforms (0.05 Second Capture) will automatically place cursors related to different faults within the waveforms. Figure 13: Special Analysis in Peak Values Figure 11: VFD Low Frequency Data In Figure 11, which is the Low Frequency (<120 Hz) data for the same system as Figure 10, shows that the output line frequency of the drive is 43 Hz and the operating speed of the 3600 RPM motor is 2570 RPM. Figure 12: VFD High Frequency Data Figure 13 shows the same data, but with the peak voltages and currents shown. The higher fequency currents indicate issues related to the voltage harmonics, which are shown in the lower waveform. All data combined shows an incoming voltage related issue. When tested at 46 Hz, the problem became more significant and pointed to a potential fault with the supply system that becomes prevalent above 45 Hz. The solution would be alleviated with filtering applied to the VFD drive output. Punch Press with Motor and Eddy-Current Drive The complete motor system can be viewed, including the driven load. Figure 14: Punch Press Load Cycle A B C As can be noted in Figure 12, strong voltage and current peaks indicate motor system related faults. Some of the additional noise is strictly due to the voltage and current waveforms that come from the VFD. However, the software Figure 14 shows the current cycle over 10 seconds. Peak A is one of three peaks in this cycle that relates to the punch (bottom) of the press stroke while point C is related to the top of the stroke. Point B identifies some type of 2004 ALL-TEST Pro Page 4 of 6 hpenrose@bjmcorp.com

rubbing or grabbing problem as the system approached the peak of the stroke. The three bottom strokes help identify that the operation is occuring 18 times per minute. Figure 15: Motor-Related Line Frequency Sidebands Figure 15 identifies a high noise floor and many sidebands around the peak LF frequency. This, along with the high frequency data, assists in pointing the direction towards the load. Figure 16: Eddy-Current Clutch High Frequency Data Additional features were funded for inclusion into MotorMaster Plus by ALL-TEST Pro, Dreisilker Electric Motors and Pruftechnik to allow for motor diagnostic information to be included for analysis. The use of both MCA and MCSA allow the user to evaluate the condition of an electric motor then make an energy-related repair versus replace decision with a confirmable return on investment. For instance, a 40 horsepower, 1800 RPM motor tested with MCSA determined some mechanical and electrical related faults. The data was incorporated into a MotorMaster Plus report and the operating frequency was determined as 91.5% efficient at 90% load. Assuming an energy cost of $0.07/kWh and $14/kW demand, with 2000 (1 shift) operating per year, a replacement premium efficient electric motor was identified with a 0.9 year simple payback and 866% after tax return on investment. Data can also be utilized by the US Department of Energy s Pump System Assessment Tool (PSAT), AirMaster and other tools. Motor Diagnostic Power ALL-TEST PRO MD System The combined power of MCA and MCSA available in the ALL-TEST PRO MD kit, integrated through the EMCAT Motor Management Software system, allows for the user to perform the following: Figure 16 identifies that a connection and/or SCR fault exists in the supply DC voltage from the rectifier (six SCR s). The peaks in the high frequency spectrum also identify faults in the eddy-current drive and the punch press itself, most likely looseness in the system (related signatures show raised noise floors). MCSA and Energy Applications The automated reporting and data-logging features of the ATPOL system also include the ability to work along with the US Department of Energy s MotorMaster Plus software. Automated analysis of both MCA and MCSA data. Payback calculation through the Power System Manager and MotorMaster Plus software systems. Commissioning of electrical machinery Troubleshooting of electrical machinery Trending of electrical machinery Root-Cause-Analysis of electrical machinery Complete system view of the electrical and mechanical health Evaluation of AC/DC systems, loads through soft coupling systems (ie: eddy-current drives) Energy studies and surveys. 2004 ALL-TEST Pro Page 5 of 6 hpenrose@bjmcorp.com

Supports other diagnostic technologies such as vibration, infrared and more. All through a simple motor diagnostic system. Data can be collected using the hand-held data collectors or through the remote-operation capability via a computer or laptop (system can be operated remotely from a computer screen). Conclusion The purpose of this ALL-TEST Pro white paper was to present the MCSA capabilities of the ALL-TEST PRO MD motor diagnostic system. The capabilities, as demonstrated, go well beyond the simple analysis of induction motors and include: AC Motors and Alternators DC Motors and Generators Single and Three phase systems Eddy-Current drives Variable Frequency Drives Incoming power quality Driven load Much more waste stream and production industrial surveys. Dr Penrose has repaired, troubleshot, designed, installed or researched a great many technologies that have been, or will be, introduced into industry. He has coordinated US DOE and Utility projects including the industryfunded modifications to the US Department of Energy s MotorMaster Plus software in 2000 and the development of the Pacific Gas and Electric Motor System Performance Analysis Tool (PAT) project. Dr. Penrose is the Vice- Chair of the Connecticut Section IEEE (institute of electrical and electronics engineers), a past- Chair of the Chicago Section IEEE, Past Chair of the Chicago Section Chapters of the Dielectric and Electrical Insulation Society and Power Electronics Society of IEEE, is a member of the Vibration Institute, Electrical Manufacturing and Coil Winding Association, the International Maintenance Institute, NETA and MENSA. He has numerous articles, books and professional papers published in a number of industrial topics and is a US Department of Energy MotorMaster Certified Professional, as well as a trained vibration analyst, infrared analyst and motor circuit analyst. The capabilities have gone far beyond those cited in this paper. Additional papers will be presented that identify opportunities using power quality, MCA, MCSA and load-related fault detection. About the Author Dr. Penrose joined ALL-TEST Pro in 1999 following fifteen years in the electrical equipment repair, field service and research and development fields. Starting as an electric motor repair journeyman in the US Navy, Dr. Penrose lead and developed motor system maintenance and management programs within industry for service companies, the US Department of Energy, utilities, states, and many others. Dr. Penrose taught engineering at the University of Illinois at Chicago as an Adjunct Professor of Electrical, Mechanical and Industrial Engineering as well as serving as a Senior Research Engineer at the UIC Energy Resources Center performing energy, reliability, 2004 ALL-TEST Pro Page 6 of 6 hpenrose@bjmcorp.com