MEASUREMENTS AND ERRORS



Similar documents
Apparatus error for each piece of equipment = 100 x margin of error quantity measured

GCE Chemistry PSA14: A2 Physical Chemistry Determine an equilibrium contstant

DETERMINING THE ENTHALPY OF FORMATION OF CaCO 3

hij Teacher Resource Bank GCE Chemistry PSA10: A2 Inorganic Chemistry Carry out a redox titration

The introduction of your report should be written on the on the topic of the role of indicators on acid base titrations.

Welcome to Physics 40!

Instructions Answer all questions in the spaces provided. Do all rough work in this book. Cross through any work you do not want to be marked.

EDEXCEL INTERNATIONAL GCSE CHEMISTRY EDEXCEL CERTIFICATE IN CHEMISTRY ANSWERS SECTION E

Experiment 1: Measurement and Density

Measurement and Calibration

Chemistry 119: Experiment 7. Potentiometric Titration of Ascorbic Acid in Vitamin C Tablets

MEMORANDUM GRADE 11. PHYSICAL SCIENCES: CHEMISTRY Paper 2

Exp 13 Volumetric Analysis: Acid-Base titration

Transfer of heat energy often occurs during chemical reactions. A reaction

Simulation of the determination of lead azide content in waste water from explosives manufacture

Stoichiometry Limiting Reagent Laboratory. Chemistry 118 Laboratory University of Massachusetts, Boston

AP Chemistry A. Allan Chapter 1 Notes - Chemical Foundations

Gravimetric determination of pipette errors

Calibration of Volumetric Glassware

THE LABORATORY NOTEBOOK

Practical 1: Measure the molar volume of a gas

Measuring volume of gas produced Measuring precipitation (because sulphur is produced) e.g. look for X to disappear Measure mass lost

Chemistry 112 Laboratory Experiment 6: The Reaction of Aluminum and Zinc with Hydrochloric Acid

Acetic Acid Content of Vinegar: An Acid-Base Titration E10-1

(1) Hydrochloric acid reacts with sodium hypochlorite to form hypochlorous acid: NaOCl(aq) + HCl(aq) HOCl(aq) + NaCl(aq) hypochlorous acid

Error Analysis. Table 1. Capacity Tolerances for Class A Volumetric Glassware.

The volume of a penny will be calculated from its mass and density.

Calibration of Volumetric Glassware

AQA CERTIFICATE Science: Double Award

39. The determination of copper in brass

Stoichiometry Limiting Reagent Laboratory. Chemistry 118 Laboratory University of Massachusetts, Boston

Analysis of Vitamin C Using Iodine. Introduction

Adiabatic Bomb Calorimetry

Chemistry 212 VAPOR PRESSURE OF WATER LEARNING OBJECTIVES

COMMON LABORATORY APPARATUS

AP CHEMISTRY 2010 SCORING GUIDELINES (Form B)

Acid Dissociation Constants and the Titration of a Weak Acid

Experiment 1: Colligative Properties

Chemistry 11 Some Study Materials for the Final Exam

Significant Figures, Propagation of Error, Graphs and Graphing

Absorbance Spectrophotometry: Analysis of FD&C Red Food Dye #40

Lab 25. Acid-Base Titration and Neutralization Reactions: What Is the Concentration of Acetic Acid in Each Sample of Vinegar?

EXPERIMENT 2 THE HYDROLYSIS OF t-butyl CHLORIDE. PURPOSE: To verify a proposed mechanism for the hydrolysis of t-butyl Chloride.

PART I: PREPARATION OF SOLUTIONS AND STANDARDIZATION OF A BASE

Enthalpy of Combustion via Calorimetry

A Beer s Law Experiment

0610 BIOLOGY. 0610/62 Paper 6 (Alternative to Practical), maximum raw mark 40

IB Guide to Writing Lab Reports

TITRATION OF VITAMIN C

EXPERIMENT 12: Empirical Formula of a Compound

EXPERIMENT 9 Evaluation of the Universal Gas Constant, R

PREPARATION FOR CHEMISTRY LAB: COMBUSTION

Experiment 6 Coffee-cup Calorimetry

SOLUBILITY, IONIC STRENGTH AND ACTIVITY COEFFICIENTS

Figure 1. A typical Laboratory Thermometer graduated in C.

Determination of the enthalpy of combustion using a bomb calorimeter TEC

Density Determinations and Various Methods to Measure

Paper 2 (7404/2): Organic and Physical Chemistry Mark scheme

To measure the solubility of a salt in water over a range of temperatures and to construct a graph representing the salt solubility.

Element of same atomic number, but different atomic mass o Example: Hydrogen

Assessment of Accuracy and Precision

Introduction to Error Analysis

Chemistry. The student will be able to identify and apply basic safety procedures and identify basic equipment.

Determination of Aspirin using Back Titration

1. What is the molecular formula of a compound with the empirical formula PO and a gram-molecular mass of 284 grams?

EDTA Titrations 1: Standardization of EDTA and Analysis of Zinc in a Supplement Tablet. by Professor David Cash. September, 2008

Chapter 2 Measurement and Problem Solving

Paper 1 (7404/1): Inorganic and Physical Chemistry Mark scheme

Acid Base Titration: ph Titration Curve

5.0 EXPERIMENT ON DETERMINATION OF TOTAL HARDNESS

Determining the Identity of an Unknown Weak Acid

Calibration of Glassware

The energy level diagram for this reaction is shown below.

The Determination of Acid Content in Vinegar

Solutions and Dilutions

Energy and Chemical Reactions. Characterizing Energy:

DETERMINING THE DENSITY OF LIQUIDS & SOLIDS

EXPERIMENT 15: Ideal Gas Law: Molecular Weight of a Vapor

The Determination of an Equilibrium Constant

Continuous process of sodium bicarbonate production by Solvay method

Topic 18 Acids and Bases Exercises

Thermochemistry I: Endothermic & Exothermic Reactions

HEAT OF FORMATION OF AMMONIUM NITRATE

Syllabus OC18 Use litmus or a universal indicator to test a variety of solutions, and classify these as acidic, basic or neutral

Juice Titration. Background. Acid/Base Titration

How to prepare standard solutions

Determination of the Amount of Acid Neutralized by an Antacid Tablet Using Back Titration

Precipitation Titration: Determination of Chloride by the Mohr Method by Dr. Deniz Korkmaz

Where the exp subscripts refer to the experimental temperature and pressure acquired in the laboratory.

Chapter 1 Lecture Notes: Science and Measurements

Introductory Chemistry, 3 rd Edition Nivaldo Tro. Roy Kennedy Massachusetts Bay Community College Wellesley Hills, Maqqwertd ygoijpk[l

Meeting the Traceability requirements of ISO An Analyst's Guide Second Edition November 2003

Acid-Base Titrations Using ph Measurements

The relationship between the concentration of a reactant and the rate of reaction with respect to that reactant can be shown using rate time graphs.

Vitamin C Content of Fruit Juice

ANALYSIS OF FOOD AND NATURAL PRODUCTS LABORATORY EXERCISE

Analytical Chemistry Lab Reports

Laboratory Exercise: The Precision of Volume Measurements

Science 20. Unit A: Chemical Change. Assignment Booklet A1

GCSE Further Additional Science. Higher Tier. Unit 2 Chemistry 3H SPECIMEN MARK SCHEME V1

Transcription:

Measurements 1 MESUREMENTS ND ERRORS ccuracy Error Precision Uncertainty Reliability measure of the closeness of agreement between an individual result and the accepted value. n accurate result is in close agreement with the accepted value. The difference between an individual measurement and the true value (or accepted reference value) of the quantity being measured. The closeness of agreement between independent measurements obtained under the same conditions. It depends only on the distribution of random errors (i.e. the spread of measurements) and does not relate to the true value. n estimate attached to a measurement which characterises the range of values within which the true value is said to lie. It is written, for example, as 44.0 ± 0.4. The opposite of uncertainty; high uncertainty = not very reliable measurement ccuracy of measurements Uncertainty is often taken to be half a division on either side of the smallest unit on the scale. However, the accuracy of measurements also depends on the quality of the apparatus used (e.g. Grade or Grade glassware.) example If a 100 cm 3 measuring cylinder is graduated in 1 cm 3 divisions. Class - maximum error of half a division (0.5 cm 3 ) Class - maximum error of a whole division (1 cm 3 ) Glassware When glassware is manufactured there will always be a maximum error. This is usually marked on the glassware. Temperature Volumetric equipment must not get warm because expansion of the glass will alter the volume; the temperature is marked on the apparatus. In or out? pparatus either... holds an accurate measure (IN) or delivers an accurate volume (EX) volumetric flask burette measuring cylinder pipette Ex 20 C 25 cm 3 Ex 20 C 25cm 3 In 20 C 250 cm 3 In 20 C 250cm 3

2 Measurements Reading values Digital top pan balance or ph meter record all the digits shown 67.36 67.356 2-places 3-places Non-digital burette, measuring cylinder record all the figures that are known for certain read to half a division for a burette, record values to two decimal places ending in a 5 or a 0 26.0 2.0 2.0 27.0 3.0 3.0 26.50 cm 3 3.00 cm 3 2.45 cm 3 Maximum errors urette graduated in divisions every 0.1 cm 3 maximum error is half a division i.e. ± 0.05 cm 3 burettes are read twice, so the overall maximum error is 2 x 0.05 = ± 0.1 cm 3 Pipette a 25 cm 3 pipette has a maximum error of 0.06 cm 3 like all volumetric equipment it must be used properly Q.1 Calculate the maximum error of a... 50 cm 3 measuring cylinder cm 3 10 cm 3 measuring cylinder cm 3 alances a two-decimal place balance may a three-decimal place balance may have a maximum error of 0.005 g have a maximum error of 0.0005 g 67.32 67.33 67.357 67.356 The significance of the maximum error in a measurement depends upon how large a quantity is being measured. It is useful to quote this error as a percentage error.

Measurements 3 Percentage based on two factors - maximum error Error - value of measurement percentage error = maximum error x 100% value of measurement the smaller the value measured, the greater the percentage error Volumetric maximum error = 0.2 cm 3 flask (250 cm 3 ) percentage error = 0.2 cm 3 x 100 = 0.08% 250 cm 3 Pipette maximum error = 0.06 cm 3 (25 cm 3 ) percentage error = 0.06 cm 3 x 100 = 0.24% 25 cm 3 urette maximum error = 0.05 cm 3 per reading 0.10 cm 3 per titration (you read it twice) percentage error depends on the volume delivered (the smaller the volume, the bigger the % error) for a 25.00 cm 3 delivery = 0.10 cm 3 x 100 = 0.40% 25.00 cm 3 for a 15.00 cm 3 delivery = 0.10 cm 3 x 100 = 0.67% 15.00 cm 3 2-decimal place top-pan balance mass of beaker + solid = 32.56 g maximum error = 0.005 g mass of empty beaker = 32.16 g maximum error = 0.005 g mass of solid = 0.40 g maximum error = 0.01g percentage error = 0.01 g x 100 = 2.5% 0.40 g 3-decimal place top-pan balance maximum error over two readings will be 0.001 g (2 x 0.0005) using the above values, percentage error will be = 0.25%

4 Measurements Thermometers Scale maximum error depends on the scale and how many degrees per division maximum error when measuring a temperature change is one division Temperature change the greater the temperature change, the lower the percentage error Q.2 What is the reading on each thermometer? C C 21 22 What is the maximum error involved? 20 20 Calculate the percentage error measuring a temperature change of 20 C using Calculate the percentage error measuring a temperature change of 2 C using Significant figures When quoting a result, it should contain the same number of significant figures as the measurement that has the smallest number of significant figures. Rounding off if the last figure is between 5 and 9 inclusive round up if the last figure is between 0 and 4 inclusive round down should only be done at the end of a calculation should not be done after each step of a calculation (it causes rounding errors) example 50.67 rounded to 3 sig figs is 50.7 2 sig figs is 51 1 sig figs is 100 for larger numbers, use standard form example 371 rounded to 2 sig figs is 3.7 x 10 2 3 sig figs is 3.71 x 10 2

Measurements 5 Recording volumes during titrations urette measurements should be recorded to 2 decimal places with the last figure either 0 or 5. During a titration, initial and final burette readings should be taken; the titre (actual volume delivered) is calculated by difference. Record titration results in a table as shown below. pprox 1 2 3 final volume / cm 3 26.00 26.75 30.85 24.60 initial volume / cm 3 1.00 2.30 6.00 0.25 titre / cm 3 25.00 24.45 24.85 24.35 tick if used to calculate mean Mean titres repeat the titrations until there are two concordant titres (within 0.10 cm 3 ) take an average of the concordant titres if this is not possible, use the two titres that have the closest agreement example the two concordant titres are the 1st and 3rd (within 0.1 cm 3 of each other) mean (average) titre value = 24.45 cm 3 + 24.35 cm 3 = 25.40 cm 3 overall maximum error = 2 x 0.05 = 0.10 cm 3 overall percentage error = 0.10 cm 3 x 100 = 0.39% 2 25.40 cm 3 There is a case for arguing that the accumulated errors indicate that one decimal place is more appropriate but this should not be used. The maximum error is the worst-case scenario and it is likely that the actual titre will in reality be more accurate than one decimal place. If concordant titres within 0.05 cm 3 of one another are found there is a problem when calculating the mean titre. For example, a student may obtain three recorded titres of 24.45 cm 3, 24.85 cm 3 and 24.40 cm 3. mean titre value = 24.45 cm 3 + 24.40 cm 3 = 24.425 cm 3 2 This mean titre has a value that is more accurate than the burette can measure. The value of 24.425 cm 3 should more correctly be rounded to 24.43 cm 3. It would seem very unfair not to credit a mean titre of 24.425 cm 3 in this case, especially as the results showed a better concordancy. In assessed level practical tasks, the mean of two titres of 25.25 cm 3 and 25.20 cm 3 will be allowed as 25.2, 25.20, 25.25 or 25.225 cm 3.

6 Measurements Errors in procedure The accuracy of a final result also depends on the procedure used. For example, in an enthalpy experiment, the measurement of a temperature change may be precise but there may be large heat losses to the surroundings which affect the accuracy of overall result. nomalous readings Where an experiment uses repeated measurements of the same quantity, (e.g. titrations) anomalous readings should be identified. If a titre is clearly outside the range of all other readings, it can be judged as being anomalous and should be ignored when the mean titre is calculated. If a plotted graph reveals that a value is anomalous, then it too should be ignored. Introducing rounding errors in multi-step calculations Example When 6.074 g of a carbonate is reacted with 50.0 cm 3 of 2.0 mol dm -3 HCl(aq) (which is an excess), a temperature rise of 5.5 C is obtained. [The specific heat capacity of the solution is 4.18 J g -1 K -1 ] Heat produced = 50.0 x 4.18 x 5.5 = 1149.5 J = 1.1495 kj (by calculator) Since the least certain measurement (the temperature rise) is only to 2 significant figures the answer should also be quoted to 2 significant figures. Therefore, the heat produced should be quoted as 1.1 kj If this figure is to be used subsequently to calculate the enthalpy change per mole then a rounding error will be produced. The 1.1495 kj value must be used. For example, if the carbonate has a molar mass of 84.3 g mol -1, the enthalpy change per mole of carbonate can be calculated from the value above. Using the calculator value of 1.1495 kj for the heat produced enthalpy per mole = 15.95371255 kj mol -1 = 16 kj mol -1 (to 2 sig figs) Using the rounded value of 1.1 kj for the heat produced, enthalpy per mole = 15.26671057 kj mol -1 = 15 kj mol -1 (to 2 sig figs) Rounding to 2 sig figs too early produces a rounding error. References The Royal Society of Chemistry has produced several very helpful documents on measurements and errors; www.rsc.org/education/teachers/learnnet/pdf/learnnet/rscmeasurements_teacher.pdf www.rsc.org/pdf/amc/brief13.pdf