Radiation Safety for Dental Auxiliaries Dr. Bruno Correa de Azevedo



Similar documents
Dental Radiography collimator Ionising radiation image radiolucent area radiopaque area controlled zone scatter radiation intraoral

Radiation safety in dental radiography

Radiation safety in dental radiography

Dental Radiology Related With Pedodontics

Integrated Management & Educational Consultancy

Bitewing Radiography B.E. DIXON. B.D.S., M.Sc., D.P.D.S.

KODAK Dental Radiography Series. Successful Panoramic Radiography DENTAL PRODUCTS

Periapical radiography

Production of X-rays and Interactions of X-rays with Matter

Radiation Protection Update

Intraoral Radiographic Techniques

Radiographic Image Production. Radiographic Image Production. Principles of Imaging Science I (RAD 119) Film, Screens, and Cassettes

Production of X-rays. Radiation Safety Training for Analytical X-Ray Devices Module 9

X-ray Production. Target Interactions. Principles of Imaging Science I (RAD119) X-ray Production & Emission

What Parents Should Know about the Safety of Dental Radiology.

user's manual _19

INTENSIFYING SCREENS, CASSETTES AND SCREEN FILMS N. Serman & S. Singer

QUALITY ASSURANCE IN DENTAL RADIOGRAPHY. Part of the Ionising Radiation Regulations Section 4 (3) IR(ME)R 2000

Radiographic Grid. Principles of Imaging Science II (RAD 120) Image-Forming X-Rays. Radiographic Grids

PROCESSING THE RADIOGRAPH. Neill Serman. Sept W + P. Chapter 6

Introduction to Dental Anatomy

WARNING: We recommend that you consult the Safety, Regulatory and Technical Specification User Guide before using the CS 2200.

Simplified Positioning for Dental Radiology

PRACTICAL TIPS IN ENSURING RADIATION SAFETY IN THE USE OF MEDICAL DIAGNOSTIC X-RAY EQUIPMENT

SECTION 1: REQUIREMENTS FOR CERTIFICATES OF COMPLIANCE FOR CLASSES OF RADIATION APPARATUS

SUMMARY OF CURRENT UK LEGISLATION AND GUIDELINES

Put Your Panoramic Imaging on Steroids While Reducing the Patient s Dose!

ProOne Digital X-ray Imaging Hardware Diagrams and System Requirements

Radiation Safety In Dental Practice

X-ray Imaging Systems

Radiation Safety In Dental Practice

DENTAL RADIOGRAPHIC EXAMINATIONS: RECOMMENDATIONS FOR PATIENT SELECTION AND LIMITING RADIATION EXPOSURE

In the previous presentation, we discussed how x-rays were discovered and how they are generated at the atomic level. Today we will begin the

Required RS Training Info

SECTION 1: REQUIREMENTS FOR CERTIFICATES OF COMPLIANCE FOR CLASSES OF RADIATION SOURCES

Intraoral Radiography: Positioning and Radiation Protection. A Peer-Reviewed Publication Written by Gail F. Williamson, RDH, MS

X-ray Radiation Safety Course. James Kane & Rob Deters Office of Radiological Control

There is no question: X Rays help dentists care for children. Select x rays for individual s needs, not merely as a routine

X-Mind. Instinct for perfection

CONTENT SPECIFICATIONS FOR THE FLUOROSCOPY EXAMINATION

X-ray (Radiography), Chest

X-ray (Radiography) - Bone

X-ray (Radiography) - Abdomen

Classification of Malocclusion

Job Ready Assessment Blueprint. Dental Assisting. Test Code: 4126 / Version: 01. Copyright All Rights Reserved.

X-ray (Radiography) - Chest

SECTION 1: REQUIREMENTS FOR CERTIFICATES OF COMPLIANCE FOR CLASSES OF RADIATION APPARATUS

CHAPTER 5 QC Test For Radiographic Equipment. Prepared by:- Kamarul Amin bin Abu Bakar School of Medical Imaging KLMUC

SAFELIGHT FILTERS AND DARKROOM LAMPS

Image Quality and Radiation Dose for Intraoral Radiography: Hand-Held Held (Nomad), Battery Powered

Veraviewepocs 3D R100 & F40

The effects of radiation on the body can be divided into Stochastic (random) effects and deterministic or Non-stochastic effects.

KODAK Dental Radiography Series. Quality Assurance in Dental Radiography DENTAL PRODUCTS

SECTION 1: REQUIREMENTS FOR CERTIFICATES OF COMPLIANCE FOR CLASSES OF RADIATION APPARATUS

1. Orthovoltage vs. megavoltage x-rays. (AL) External beam radiation sources: Orthovoltage radiotherapy: kv range

Radiation Safety Issues for Radiologic Technologists

Veraviewepocs 3D R100 & F40

X-ray Imaging Systems

Radiation Safety Characteristics of the NOMAD Portable X-ray System

Residency Competency and Proficiency Statements

Dental Radiography Core Subject. Digital Radiography

REGULATION: QUALITY ASSURANCE PROGRAMS FOR MEDICAL DIAGNOSTIC X-RAY INSTALLATIONS N.J.A.C. 7:28-22

Removable appliances II. Functional jaw orthopedics

DENTAL Cone beam 3D X-RAY SYSTEM with

A collection of pus. Usually forms because of infection. A tooth or tooth structure which is responsible for the anchorage of a bridge or a denture.

IMPLANT CONSENT FORM WHAT ARE DENTAL IMPLANTS?

Standard Test Method for Classification of Film Systems for Industrial Radiography 1

Course Curriculum for the Master Degree in Dentistry/Orthodontics

X-RAY REGULATORY GUIDE

Environmental Health and Safety Radiation Safety. Module 1. Radiation Safety Fundamentals

CODE OF PRACTICE & SAFETY GUIDE

Page: 1 of 6 Page: 1 of 6

Headgear Appliances. Dentofacial Orthopedics and Orthodontics. A Common Misconception. What is Headgear? Ideal Orthodontic Treatment Sequence

Essential points for X-ray technicians

5.2 ASSESSMENT OF X-RAY TUBE LEAKAGE RADIATION AND X-RAY TUBE OUTPUT TOTAL FILTRATION

JB-70 Dental X-Ray System

DEVELOPMENT AND GROWTH OF THE MANDIBLE

SECTION 1: REQUIREMENTS FOR CERTIFICATES OF COMPLIANCE FOR CLASSES OF RADIATION APPARATUS

CHAPTER 10 RESTS AND PREPARATIONS. 4. Serve as a reference point for evaluating the fit of the framework to the teeth.

X-Rays Benefits and Risks. Techniques that use x-rays

Elements of required physical infrastructures: space, schielding, and patient flow..

SUBCHAPTER 22 QUALITY ASSURANCE PROGRAMS FOR MEDICAL DIAGNOSTIC X-RAY INSTALLATIONS

Case Report(s): Uncomplicated Crown Fractures

Job Ready Assessment Blueprint. Dental Assisting. Test Code: 4026 / Version: 01

MEDICAID DENTAL PROGRAMS CODING, POLICY AND RELATED FEE REVISION INFORMATION

portable x-ray survey report

Southern California Veterinary Dental Specialties & Oral Surgery

Displays. Cathode Ray Tube. Semiconductor Elements. Basic applications. Oscilloscope TV Old monitors. 2009, Associate Professor PhD. T.

Analytical X-ray Safety Refresh Training. Radiation Safety Officer Department of Environmental Health and Safety

CS D Panoramic Cephalometric. Innovation, in reach

Digital radiography conquers the veterinary world

Humana Health Plans of Florida. Important:

PHOTOELECTRIC EFFECT AND DUAL NATURE OF MATTER AND RADIATIONS

Anatomic Anomalies. Anomalies. Anomalies. Anomalies. Supernumerary Teeth. Supernumerary Teeth. Steven R. Singer, DDS

The professional for your diagnostics.

Oftentimes, as implant surgeons, we are

Dental Clinical Criteria and Documentation Requirements

GENERAL SHIELDING REQUIREMENTS FOR DIAGNOSTIC X-RAY FACILITIES. Major Medical (Radio/Fluoro/CT/Cardiac/Chiropractic)

ABSTRACT INTRODUCTION. Facial Esthetics. Dental Esthetics

Digital Radiography in Dentistry: Moving from Film-based to Digital Imaging

Transcription:

Radiation Safety for Dental Auxiliaries Dr. Bruno Correa de Azevedo Course Content 1. Radiation History and the Use of Radiographs 2. Introduction to Physics 3. X-ray Machine and Production of X-Rays 4. Radiographic Film and Processing 5. Radiation Biology 6. Radiation Safety 7. Intra-Oral Radiographic Techniques 8. Introduction to Panoramics

1. Radiation History and the Use of Radiographs A. Outline- History Discovered in 1895 - Wilhelm Roentgen - Recorded on photographic plates - Public reaction and Medical Uses Dangers of X-rays - C. Edmund Kells - X-ray properties Advances - Safety equipment - Film - Digital B. Use of Radiographs Why? - Used in diagnosis, treatment planning, monitoring disease, provide information during procedures Intraoral radiograph- high detail, limited area - Periapical radiograph- around the apex crown, root and 3mm around apex - Occlusal radiograph- impacted/embedded teeth, foreign bodies, fractures, salivary stones, large tumors or lesions Extraoral radiograph- additional information is needed - Panoramic- most common - Cephalometric - PA skull, Waters, TMJ, CT

Radiographic Selection Criteria - Dental Caries - Periodontal Disease - Other conditions 2. Introduction to Physics Atomic Structure - Structure of atom - Ionization- collision events, - effects of ionization - Types of Radiation - Electromagnetic and Particulate - Electromagnetic spectrum - Properties of Electromagnetic Spectrum - Specific Properties of X-Rays 3. X-Ray Machine and Production of X-Rays A. Components of X-Ray Equipment Supporting Arm Control Panel 1. on/off switch 2. Milliamperage selector (ma) 3. Kilovoltage selector (kvp) 4. Timer

5. Exposure switch- dead man 6. X-ray emission light and audible signal Tube Head - Cathode-(-) tungsten filament - Anode- (+) tungsten target, copper sheath - Transformers - Oil - Tube housing- metal - Filtration 1. inherent 2. added - Collimation B. Production of X-Rays Step by Step - Tube head 1. Operator turns on machine and sets exposure factors (ma, time, kvp) 2. Operator holds down exposure button 3. Step-down transformer reduces 110 or 220 volts to 3 to 5 volts 4. Filament heats up- ma tells how many electrons to produce- thermionic emission 5. Step-up transformer (65 to 90 kvp) accelerates electrons to anode target 6. X-rays leave the glass tube filtered to remove long wavelength, collimated to reduce size of beam, guided through PID (cone) 7. Produces 1% radiation

Types of Radiation a. Leakage Radiation b. Primary Radiation c. Scatter Radiation d. Remnant Radiation e. Secondary Radiation 4. Radiographic Film and Processing A. Image concepts Definitions- 1. Image receptor- physical media affected by x-rays and produces an imagefilm, digital sensor 2. Latent image- invisible image 3. Visible image- latent image converted to visible image by chemicals Film -transparent plastic base - radiation sensitive silver bromide emulsion - lead foil- protects film from backscatter radiation - black paper - embossed dot- tells right from left Film Sizes #0- periapical and bitewing for small children #1 anterior periapical adult #2 periapical and bitewing adults Occlusal view for small children #3 bitewings (seldom used) #4 occlusal views

Digital Sensors- pixel based B. Characteristics: - Film Sensitivity- speed- size of crystals - Density- degree of darkening - Contrast- differences in density - Sharpness or definition C. Film Handling and Storage Radiographic film is sensitive to a number of variables Improper handling- pressure sensitive- fingernails, bending, dirt, chemical spills Heat and humidity- should not be stored at temperatures above 68 F Should be stored between 40% and 60% humidity Should be stored and handled in darkroom Radiation- fog from scatter radiation Age- expiration date- indicates maximum shelf life D. Darkroom Chemistry and Processing Steps in Chemical Processing 1. Develop 2. Rinse 3. Fix 4. Wash 5. Dry Developer : - Time/Temperature Method- brings out image - Softens and swells emulsion - Principle components- Hydroquinone- produces black tones Elon- produces grey tones

Fixer: - removes unexposed and undeveloped silver bromide crystals - Stops developing action - Hardens emulsion to prevent damage Automatic processing- series of rollers, concentrated chemicals Shortened processing time Safe Light-safe illumination - Safelight and distance- 4 feet from working area - Safelight and time- limited working time - Safelight and filter- manufacture recommendation - Safelight and wattage- recommended is 15 watts Coin test for: safelight problems, light leaks

5. Radiation Biology I. Basic Interactions of X-Rays: A. No interaction X-rays pass through Radiolucent area on radiograph (dark space) Structures that are easily penetrated- soft tissue, pulp B. Attenuation 1. Photoelectric Absorption- radiopaque- bone, metal Results in production of photoelecton and secondary radiation- both are poorly penetrating and completely absorbed Accounts for most interactions in dental radiology 2. Scattering Absorption of x-ray and re-emission of x-rays at angles Reaches the film and produces fog Majority of genetic and somatic exposure and can be hazardous to operator Compton scatter- x-rays are deflected and reduced in energy (long wavelength) II. Mechanism of effects A. Atomic level- energy transfer from ionizing radiation to atoms of biologic tissues ionization- loss of electron leaves atom with positive charge B. Molecular level- Direct effect- occurs when molecules such as DNA, RNA, proteins, etc receive energy directly from the incident radiation Indirect- occurs as result of ionization of water in cell- forms toxin and damages cell

C. Cellular level- Somatic cells- all cells of the body except genetic Genetic cells- reproductive cell Mechanisms- direct or indirect damage - Cell death - Disruptions in cell growth - Permeability changes - Changes in cell motility D. Tissue level Law of Bergonie and Tribondeau Cell sensitivity - Actively dividing cells are more sensitive than slowly dividing cells - Cell is most sensitive during mitosis (cell division) - Immature cells are more sensitive than mature cells White blood cells Red blood cells Immature reproductive cells Epithelial cells Endothelial cells Connective tissue cells Bone cells Nerve cells Brain cells Muscle cells High sensitivity Low sensitivity E. Organ level Critical Organ Concept- certain organs more susceptible to radiation

III. Factors that Determine Radiation Injury Total Dose Dose Rate Area exposed Cell sensitivity Age IV. Sequence of Events following Radiation Exposure A. Latent period B. Period of injury C. Recovery period V. Radiation Effects in Dentistry A. Stochastic Effects- when the dose of radiation is increased, the probability of the effect increases, but not its severity Cancer Genetic mutations B. Deterministic Effects effects that increase in severity with increasing absorbed dose Erythema (reddening of the skin) Epilation (loss of hair) Cataract formation C. Short and long term effects: 1. Short term are seen minutes, days, months after exposure ARS- Acute Radiation Syndrome- If dose is arge enough (usually over 100 rads, whole body) ARS- erythema, nausea, vomiting, diarrhea, hemorrhage 2. Long term effects are seen years after exposure Cancer, birth defects, cataracts, genetic mutations

VI. Patient concerns about Radiation- Risk A. Biological risks in dental radiation are low compared to medical, but patients may be concerned B. Risks compared to: Background radiation- sources of background radiation Area of exposure: Whole body High dose Whole body- Low dose Limited area- High dose Limited area- Low dose 6. Radiation Safety and Protection I. Concepts in Radiation Protection A. ALARA principle- As Low As Reasonably Achievable B. Risk vs Benefit II. Patient Protection A. Prescribing radiographs ADA and FDA guidelines- recommendations for prescribing dental radiographs Every patient is evaluated for radiographs on an individual basis Every exposure must be clinically indicated No radiograph should be taken unless used for diagnostic purposes B. Proper Equipment 1. Filtration Added filtration- Aluminum filters to remove long wavelength, low energy radiation Inherent filtration- glass window, insulating oil, tubehead seal Total filtration- State and Federal laws require total filtration (added +inherent) to have 1.5 mm aluminum for x-ray machines operating at or

below 70 kvp and 2.5 mm of aluminum for all machines operating above 70 kvp 2. Collimation Lead plate with a hole where x-ray beam exits the tubehead Used to restrict the size and shape of the x-ray beam May be round or rectangular depending on shape of the opening of the cone Beam must be no larger than 2.75 inches at patient s face 3. Position Indicating Device (PID) or cone Extension of x-ray tubehead used to direct the beam 3 types- conical, round and rectangular - Conical no longer used in dentistry because of production of scatter radiation - Rectangular- most effective in reducing patient exposure 4. Thyroid collar lead shield used to protect thyroid gland from scatter radiation is recommended (not mandated) for all intraoral exposures- esp in small children and adults with thyroid disorders not recommended for extraoral exposures since it obscures information 5. Lead apron flexible shield placed over chest and lap to protect reproductive organs from scatter radiation recommended for intraoral and extra oral placed on back during panoramic exposures) lead free with alloy sheeting are available 6. Fast film most effective method of reducing patient exposure to radiation F-speed film is the fastest intraoral film available Digital imaging is 50 to 90% less exposure to patients than intraoral film

7. Beam alignment devices Film or Sensor holders- helps stabilize receptor in the mouth and reduces chance of movement 8. Exposure Factor selection Limits the amount of x-radiation exposure a patient receives Adjusting the kilovoltage, milliamperage and exposure time 9. Proper technique Helps ensure diagnostic quality and reduce amount of radiation to patient Images that are non-diagnostic must be retaken which results in additional exposure to patient Retakes must be avoided at all times Proper film/sensor handling Proper film processing/ image retrieval III. Operator Protection 1. Distance, Positioning and Shielding must stand at least 6 feet away from the tube head during exposure position at a 90 degree angle from primary beam (travels in straight line) protective barriers (several thicknesses of drywall, cinderblock walls, etc) NEVER hold a film in place during exposure NEVER hold the tube head during exposure NEVER hold the patient 2. Monitoring Equipment monitoring- quality control Personnel monitoring- film badge 3. Radiation Exposure Guidelines Radiation Safety Legislation- both state and federal government Maximum permissible dose- accumulated lifetime radiation dose for occupationally exposed workers

Formula based on workers age MAD= (N-18) x 5 rems/year IV. Patient Education 7. Intraoral Techniques I. Types of Intraoral radiographs Periapical- records images of full length of teeth and at least 2mm of surrounding bone Bitewing- recomrds crowns and coronal 1/3 rd of interproximal bone Occlusal- records images of incisal edges of teeth and cross-section of dental arches II. Intraoral Radiographic Surveys Adult FMX-(Dentate) composed of periapical and bitewing radiographs Adult FMX-(Edentulous)- composed of two occlusal films and periapical films Child- Preschool- composed of 4 molar periapicals, 2 bitewings, and 2 occlusal Child- Mixed Dentition- identical to adult FMX, but deleting molar periapicals and molar bitewings III. Basic Principles in Intraoral Radiography A. Long axis of teeth B. Head position- occlusal plane should be parallel to floor C. X-Ray beam angulations Central ray- imaginary center of x-ray beam Long axis- vertical orientation of teeth Angulation- direction the x-rays are directed toward the teeth and film - Vertical- up and down - Horizontal- movement of tube head around patient Point of entry- need to cover the film with the x-ray beam or resulting image will be cone cut

D. Paralleling Technique Preferred technique- anatomic accuracy- less distortion Fundamentals- - Must use film/sensor holder - Sensor is placed parallel as possible to long axis of tooth - Central ray is perpendicular to tooth and sensor - Increase object-sensor distance Procedure for Paralleling Technique 1. Place sensor in holder and position so it covers prescribed teeth - vertical plane- object sensor distance may need to be increased to be as parallel as possible - horizontal placement should be parallel to interproximal contacts of teeth 2. Direct patient to slowly close on biteblock 3. Slide ring to almost contact the skin 4. Align cone so it is horizontally parallel with indicator rod and center x-ray beam in ring

Paralleling Technique Using Rinn XCP Equipment Maxillary Premolar Maxillary Molar Mandibular Premolar Mandibular Molar

E. Bisecting Angle Technique Fundamentals Film is positioned at angle to tooth Imaginary line bisects the angle Align end of cone parallel to imaginary bisecting line Procedure for Bisecting Angle Technique 1. Align patient s head so occlusal plane is parallel to floor and mid-sagittal plane is perpendicular to floor 2. Use film holder and center film behind center of teeth 3. Direct central ray in vertical position so end of cone is parallel to imaginary bisecting line 4. Direct horizontal angulation so central ray does not overlap interproximal areas 5. Look to make sure central ray is completely covering sensor

8. Introduction to Panoramics I. Principles- Tomography- body sectioning revealing an image layer and Slit Radiography which is a vertical slit aperture - Wide view of upper and lower jaws - Positioned outside of mouth - Both film and tube head rotate around patient II. Purposes- A. To evaluate impacted teeth B. To evaluate eruption patterns, growth and development C. To detect disease, lesions and conditions of jaws D. To examine extent of large lesions E. To evaluate trauma III. Advantages A. Requires less technical expertise B. Easily tolerated by patient C. Minimal time requirements D. Maxilla and mandible on single film E. Radiation dose small IV. Disadvantages A. Produces an image that is less sharp- magnification, distortion and poor Definition B. Positioning of patient is critical C. May not reveal objects that are outside of the focal trough D. Requires more expensive equipment

V. Operational Controls Pre-Exposure preparation - Time is fixed - kvp is most common control altered - sign on to computer and follow instructions if digital or - load cassette and place into cassette holder - use proper infection control procedures - have patient remove all metallic objects from head - place lead apron on back and front of patient - do not use thyroid collar - explain procedure to patient and talk to them during exposure Positioning for patient - stand or sits with spine erect - anterior teeth placed in bite piece groove - Head planes: Mid-sagittal- horizontal parallel to floor Occlusal- vertical- parallel to floor Anterior posterior (forward backward) aligned - Tongue pressed against palate - Lips closed VI. Cassettes- Screens- Film A. Intensifying screens- emit fluorescent light which exposes the film B. Cassettes- rigid or soft VII. Focal Trough A. image layer where structures are well defined B. Sharpness location of focal trough C. Magnification areas of focal trough

VIII. Panoramic Errors and Ghost Images A. Characteristics of ghost images - opposite side of actual object - same shape as object - larger than actual object - projected higher on film - less distinct (ghostlike) B. Patient positioning errors C. Patient preparation errors - Too far forward - Too far back - Slumped spine - Mid sagittal plane rotated or tilted - Chin too high - Chin too low - Metallic objects left in place- earrings, necklace - Movement of tongue not raised - Clothing not removed- hats, hoodie sweatshirts - Processing errors- static electricity, film handling