Radiant Temperature Sensor TY7321



Similar documents
T7560A,B,C Digital Wall Module

FIRERAY 2000 Installation Guide

ETC TWO STAGE ELECTRONIC TEMPERATURE CONTROL

Duct Humidity Transmitter

T7079A,B Solid State Remote Temperature Controllers

12 Volt 30 Amp Digital Solar Charge Controller Installation & Operation Manual

Adjustment functions for both span and shift have been incorporated

How To Read A Pipe From A Sensor

H/L = Power supply. FN = Nominal Frequency. RN = Rated value of output burden. UN = Nominal input voltage. IN = Nominal input current.

MCR1900 Media Converter 19-Slot Chassis

Electronic Control Devices The European Product Catalogue 2007

Power supply unit Model: PAC-SC50KUA

HMI display Installation Guide

DS DRTE. AIR ROOM TEMPERATURE SENSOR with fan speed control switches

I nstallation. M100Q Series Proportional Actuator with R81Q Controller Board for Thermistor Sensor Applications. Tools Needed.

When any of the following symbols appear, read the associated information carefully. Symbol Meaning Description

Day / Night IR Color Camera User Manual V2.1.0

WD-AMX Water Detection Controllers

Bullet Camera. Installation Guide. Hangzhou Hikvision Digital Technology Co., Ltd.

Installing the Tracer ZN517 Unitary Controller Ordering number: ,

24 Wide Screen LED Monitor with HDMI

PSU-U-24V/AC-6A/10/FTA-TR-MC PSAC 0624

Solid-State Timer H3G

2013 Wireless Video Intercom INSTALLATION GUIDE

AXIS T81B22 DC 30W Midspan

REGULINE 600VA / 1000VA REGULATOR USER MANUAL

Cross-beam scanning system to detect slim objects. 100 mm in

RISH CON - Hz. Salient Features : Application : Product Features: FREQUENCY TRANSDUCER

Detector transparent with Color Inserts. FAA 500 TR P Trim Ring transparent with Color Inserts. FCA 500 / FCA 500 E Detector Bases

Differential Pressure Sensors for air and non-corrosive gases, with calibration certificate

LED Security Spotlight User Manual

T5000 T000 LCD Digital Fan Coil Thermostat

Current valve. for AC 24 V pulse/pause control of electrical loads up to 30 kw

Y7230A CO 2 Alarm System

Long sensing range. Most suitable for conveyor lines and parking lot applications. 10 m ft (Red LED)

16/32 Channel 1U Rack Mount CCTV Power Supply

Small U-shaped Micro Photoelectric Sensor. Enables space saving and quick installation!

12 Volt 30 Amp Digital Solar Charge Controller

LUCCI AIRFUSION QUEST II CEILING FAN

Programmable Room Thermostat 7 Day (5-2 Day) Models: / Power Supply: Battery / Mains

SSC-T800series. New type with radial cross ray method. Light Curtain Sensors. Type. Radial Cross Ray Method. Detecting width. Light axis interval

NFC Communication Tray Model: HHX-IT3-Z

Electronic Control Devices The European Product Catalogue 2007

Moxa EtherDevice Switch

Outdoor 33.6W Dual Port Passive Power-over-Ethernet Midspan For External Security Cameras and Wireless Access Points

PA5. Series. Quick-Connect Cables with Connectors. Simplifies sensor wiring. Wide variety of connectors attached to cables.

Infrarot-Bewegungsmelder IP44

Short Range Wireless Switch System Handheld 8 Installation and Operations Guide

Dome Camera with IR Night Vision

2.0 Installation 1. Remove the cover using a small flat blade screwdriver. Figure 2: Cover Removal

Positive-guided relay outputs: 3 safety contacts (N/O), instantaneous. 1 auxiliary contact (N/C), instantaneous

PT-6000 Power Tower INSTALLATION MANUAL SPECIFICATIONS

33.6W Power over Ethernet Waterproof Adapter PoE Plus Single Port Injector for Outdoor Application

SWITCH! DESCRIPTION. ENVIRONMENTAL SPECIFICATIONS Operating Temperature: 0 C to +40 C SPECIFICATION SHEET:

OPLC Installation Guide

Split-type Air-Conditioner INSTALLATION MANUAL CONTENTS FOR INSTALLER MXZ-3A30NA MXZ-4A36NA ATTENTION. English. Français. Español

Installation and Operation Manual. Digital Remote Meter for Monitoring System Performance. Version: RM-1

DUAL SENSING DIGITAL THERMOSTAT PRODUCT INSTRUCTIONS. Construction Automotive Industry

U-shaped Micro Photoelectric Sensor

Absolute Rotary Encoder E6CP

5W LED Energy Saver PIR Bulkhead

RY2 miniature industrial relays

Sense Components. Sense monitor. Antenna assembly. External mounting kit Current sensors. Download the Sense app. Go to sense.com/app.

Ducoterra Radiant Heating Panel Installation Manual

Solid Core and Split Core Adjustable Current Status Switches CSS-O, CSS-C; CSP-O, CSP-C

O WA-120U series IP W Single Output Switching Power Supply. Features. Aplications

Roof Top Air Conditioner INSTALLATION AND OPERATING INSTRUCTIONS

Antenna Splitter ASA 1. Instruction manual

MILLENIUM INSTALLATION MANUAL NTR 735 A. Simple Automation Control Module (MAS)

Manual Ranging MultiMeter

LOXONE 12 Channel Amplifier

Installation and Operation Guide

REV. REL 1302 WEST BEARDSLEY AVENUE P.O. BOX 1127 ELKHART IN (574) FAX (574) ELKHART BRASS MFG. CO., INC.

UV100A Ultraviolet Air Treatment System

12. Inspection and Maintenance

About the HotWire Slot Standalone Shelf

Sensing method Appearance a Connection o method Sensing distance Model NPN output PNP output Through-beam Pre-wired (see note 3) Connector.

IO-DIM6 6-Channel, Digital to Analogue Converters

RI-215A Operator s Manual. Part Number: RK Revision 0 Released: 10/3/05

Electronic timer CT-AHD.12 OFF-delayed with 1 c/o (SPDT) contact

Product and Applications Description. Application Programs. Example of Operation. GAMMA instabus Technical Product-Information.

User Manual. RK-2d / RK-2t. dedicated KVM switch and rackmount screen technology. Designed and manufactured by Austin Hughes

Room Temperature Sensors

AutoRanging Digital MultiMeter

Cooktop Low-Profile Ventilation Hoods

! WARNING. Before using product, read and understand instructions.

aseries A13B Mini Bullet Camera User Manual

Single Channel Loop Detector

Drayton Digistat +2RF/+3RF

No. : EX##-OMF0004 OPERATION MANUAL. SI unit EX12#-SMB1

DLP-PU/E Instruction Manual

Three-phase Asymmetry and Phase-sequence Phase-loss Relay K8AB-PA

Specifications H8CA-S H8CA-S RATINGS. Approved by the following standards CHARACTERISTICS

Clear Glass Sensor. Ordering Information E3S-CR67/62. Optimum Sensor for Detecting Transparent Glass and Plastic Bottles

COLOR TFT LCD MONITOR. User Manual

3 Port Solenoid Valve

Telefon (+45) Telefax (+45) Installation and operating manual

FLUORESCENT UV- RING LIGHT OPERATING INSTRUCTION

UHIR Series. Horizontal or Vertical Mounting Industrial / Commercial Electric Unit Heater. Owner s Manual

PSACH v.1.0 PSACH 24VAC/6A/1x6A HERMETIC AC power supply for CCTV

Transcription:

AB-5361-U Specifications/Instructions Radiant Temperature TY7321 General TY7321 Radiant Temperature s are designed to measure infrared radiation from perimeter windows and walls and provide a proportional output for use in resetting the space temperature control setpoint in heating, ventilating and air conditioning control systems. The sensors use thermopile elements to measure infrared radiation. Features Radiant temperature reset provides enhanced comfort in perimeter zones where solar gain affects occupant comfort. The radiant temperature sensor provides remote measurement of radiant temperature from windows or walls. Adjustable radiant sensing window allows for easy setup in a variety of different applications. Can easily be installed in a variety of ceilings. Measurement principle All objects radiate infrared rays in relation to their surface temperatures. This radiation is especially noticeable from perimeter walls and windows. Detecting the energy volume of these infrared rays allows the measurement of the radiant temperature affect. The TY7321 s thermopile sensing element converts infrared radiation to an electrical signal that is proportional to the radiant temperature. Specifications (1/2) Item Specification Sensing range Radiant temperature: 41 to 122 F (5 C to 50 C) Sensing accuracy Radiant temperature: +/- 3.6 F (+/-2 C) at an ambient temperature of 77 F (25 C) Power supply +/-15 % Frequency 50/60 Hz +/-4 % Power consumption Max. 0.3 VA Output signal Radiant temperature: 1 to 5 V DC (corresponds to radiant temperature 32 to 122 F (0 to 50 C) Time constant Radiant temperature: Max. 10 seconds Ambient temperature: 59 to 95 F (15 to 35 C) Rated conditions Ambient humidity: 10 to 90 % RH (non-condensing) Vibration: 2 m/s² (10 to 55 Hz) 1

(2/2) Item Specification Ambient temperature: -4 to 140 F (-20 to + 60 C) Transport/storage conditions Ambient humidity: 5 to 95 % RH (non-condensing) Vibration: 9.8 m/s² (packed) Effective range 52 coverage 344 (horizontal) 65 (vertical, in 5 steps) Weight Approx. 0.44 lb (200 g) Base, housing, terminal cover: DIC 546 1/2 Color Cover: White Case, housing, cover of sensor : White Base, housing, terminal cover : Molded polycarbonate resin, equivalent to UL V-O Materials Cover : Molded fire-resistant ABS resin, equivalent to UL V-O Case, housing, sensor cover : Molded polycarbonate resin, equivalent to UL V-O Models Available TY7321A1009 Radiant Temperature Safety Instructions Please read instructions carefully and use the product properly. Please keep this instruction on hand for reference at any time. Usage Restrictions This product is targeted for general air conditioning. Do not use this product in a situation where human life may be affected. If this product is used in clean rooms or places where reliability or control accuracy is particularly required, please contact Yamatake s sales representatives. Yamatake Building Systems Co., Ltd. bears no responsibility for any benefit, or lack of benefit, derived from the operation by the customer. CAUTION Installer must be a trained, experienced service technician. Check the ratings given in this instructions to prevent equipment damage. Check the environment given in this instructions to prevent equipment damage. Disconnect power supply before wiring to prevent electrical shock or equipment damage. All wiring must comply with local codes and ordinances. Use crimp contacts with insulation jackets for wire terminals. Do not remove or disassemble casing except for wiring. May result in equipment damage. Use an insulating transformer to supply 24V AC. Do not share power supply with other equipment. A loop is formed at the common and may cause equipment damage. 2 AB-5361-U

Dimensions & Parts Identification 5.85 (148.5) 3.39 (86) Base mounting screw Terminal cover Mounting bracket Packing CAUTION Disconnect power supply when wiring to prevent electrical shock and equipment damage. Wiring Instructions Shielded multi-wire cables (CVV-S) with 16 AWG (1.25 mm²) wire size is recommended. A 16 AWG (1.25 mm²) IV cable may be used. Be sure to ground the shielded cable at the controller. Use separate conduit for the 24VAC power and the sensor output signal wiring. The maximum cable length is 327 ft (100 m). 0.83 (21) 0.35 (8.8) 0.075 (1.9) Fig.1 Boxless type dimensions in. (mm) Installation Installation Location Make sure the installation is : 3.54 (90) 2.05 (52) Sensing window 0.71 (18) Always check wiring before supplying power. Always use a dedicated 24 VAC transformer. Never share the transformer with other products. Use of individual AC transformer CAUTION Use a dedicated insulated transformer to supply 24 V AC power supply voltage. Never share power supply with other equipment. If a transformer is shared with other equipment, a loop may be formed at common and the sensor may be damaged. Within the area to be sensed Not directly affected by lighting Not directly affected by discharge airflows or drafts 3 to 10 ft away from window surfaces Connection/Wiring Transformer ( power supply) shared Multi-loop controller Common share Not Good Fig.3 Multi-loop controller Terminal # Table 1 Connection destination Common share 24V AC () 24V AC ( ) Radiant temperature output (+) Radiant temperature output ( ) N.C. N.C. Not Good Common loop formed 3 AB-5361-U

Transformer () separated Multi-loop controller 4) When wiring is complete, put the terminal cover over the base. Then pass the wires along the slits and through the round holes. Terminal cover Round hole Slit Base Good No common loop formed If using the sensor with another manufacturer s controller follow these instructions to prevent an induction current flowing from the sensor to the controller input circuit, or to prevent excessive noise due to a different controller time constant. Use a controller with a low pass filter having a removal ratio of 40dB or higher (normal mode). Connect an isolator to the controller input circuit if a removal ratio is unknown. The above precautions are not required if the sensor is used in with a Yamatake controller. Fig.5 5) Insert the mounting bracket into the square holes on both sides of terminal cover. Turn the base mounting screw two or three times to attach loosely. Mounting bracket Screw Turn the base mounting screw two or three times to attach loosely Terminal cover Mounting Without A Conduit Box 1) Cut a circular opening of 2.55 in. (65 mm) diameter in the ceiling where the sensor is to be installed, and remove the sensor from the body. 2.55 in. (65 mm) Square hole Base Fig.6 6) Insert the base into the ceiling and tighten the base mounting screw. 2) Pass the wires through the opening and attach crimp-style terminals to the wires. 3) Connect the wires to the terminals of the base (refer to Connection/Wiring diagram Fig. 3 Table 1). Fig.7 Use Philip s head screwdriver(+) Fig.4 4 AB-5361-U

7) Now insert the sensor into the base. Base Align the small slot on the sensor with the tangle on the base and turn the sensor until it clicks Fig.8 8) Adjust the measurement coverage area (refer to Radiant Adjustment Section). Using an outlet box for installation box 1) Cut a circular opening of 2.75 in. (70 mm) in the ceiling board where the sensor is to be installed. Then pass wires through the board and attach crimp-style terminals. 2) Connect wires to the screw terminal of the base as shown in the Connection/Wiring diagram (Fig. 3 Table 1). 2) The radiant sensor output voltage should be between 3 and 4 VDC within 10 seconds. Radiant Adjustment Turn the setting knob so that the sensing window faces the center of the area of measurement (i.e. perimeter wall or window). Use the notched groove next to the sensing window for horizontal movement. 1) The sensor moves 0 to 65 vertically. Setting knob Fig.11 Fig.9 3) Insert the base through the opening and attach the base to the outlet box using the mounting screws. (5 ) Setting knob Fig.12 2) The sensor pivots 344 horizontally. Mounting screw Fig.10 4) Attach the sensor to the base. 5) Adjust the measurement coverage area (refer to Radiant Adjustment Section) Checkout 1) To make sure that sensor has been wired correctly, hold the palm of your hand in front of the radiant sensing window. Fig.13 Radiant Maintenance To clean the radiant sensing window, periodically wipe it lightly using a cotton swab or soft cloth and alcohol. (Do not use benzene or thinner). 5 AB-5361-U

Yamatake Sensing Control Limited 3323 Kifer Rd Santa Clara CA95051 Customer Service:1-866-SENSOR1(736-7671) Sales:1-866-SENSOR2(736-7672) Yamatake Corporation International Business Division Totate International Bldg. 2-12-19, Shibuya, Shibuya-Ku Tokyo, 150-8316, Japan First Printing Jan. 2002 6 AB-5361-U Printed in Japan. AB-5361-U 1H-H (W)