Flexit SPIRIT K2R. Air handling unit with integrated kitchen hood



Similar documents
Flexit air handling unit K2 R

NEW! Flexit SL4 R. Air Handling Unit with rotating recovery system Energy-efficient New control system. Patent applied for!

FLEXIT S4 R S6 R S7 R

News! Flexit S20 R. Air Handling Unit. A new generation of Air Handling Units. For a healthy indoor envionment

94122E FLEXIT L4 X/TT L7 X/TT. User Manual. Air Handling Unit Loft Models with Heat Recovery

94210E L7 X W. User Manual. Air Handling Unit Loft Models with water-based heating

111538E Flexit SPIRIT UNI 2. Installation Instructions. Air Treatment Unit & Automatic Control

FLEXIT S3 X/TT A3 X/TT K3 X/TT S3 R S3 RK

Flexit Central Vacuum Cleaner

Flexit Central Vacuum Cleaner

Duplexvent DV72 EC So light, so slim it fits inside a 600mm cupboard

RRV934. Multi-controller. Synco living

ECOCIAT. Domestic hot water heat recovery unit

Solar air collectors for industry and larger halls S Ø. Efficient dehumidification and air heating for free...

HVAC Processes. Lecture 7

Combi Unit Genius. The energy efficient Building Service Centre

IH E Sigma Island 90

ROOFTOP - HEAT PUMP UNIT. This document applies when installing into an air handler or as part of an air handling system.

EASYAIR flat THE COMPACT WAY TO A COMFORTABLE CLIMATE.

Installation, operation and maintenance manual TX 35A

air conditioners how to choose a cooling system

MODEL: DV72. Mechanical Ventilation with Heat Recovery Installation Instructions and User Manual. Configuration Left Hand Right Hand

Meaco 30L and Meaco 40L dehumidifier instruction manual

Energy Efficiency HOSPITALITY.

The compact unit series

Installation and maintenance instructions. Danfoss Vent

squrboxbox heat recovery squrboxbox I technical information

MY HOME IN A HOUSING BLOCK A GUIDE FOR RESIDENTS

Liebert Hiross HPW The High Performance Wallmount Cooling Solutions for Telecom Mobile Remote Access Nodes

Smoke exhaust systems

121MC. Vallox. Low-energy ventilation unit with heat recovery. Operating, maintenance and technical instructions. Vallox EN 14.5.

Air conditioning unit Saphir vario. 2. Product information for the new Truma air conditioning unit. Comfort on the move

Horizontal ventilation units

cairn HMO Tenant Information Property Address: Letting: Maintenance:

ComfoAir 350 Luxe User Manual

Infrarot-Bewegungsmelder IP44

Zehnder Focus 200. Ventilation device

A Prototype Alternative Ventilation System for Retrofit, Rehab and Renovation of Rural Alaska Houses

Hitachi Air Conditioning. Engineered for tomorrow. Room Air Conditioning GENERAL CATALOGUE

USER MANUAL HRV CONSTRUCTO 2.0ES* HRV CONSTRUCTO 1.5ES* * THESE PRODUCTS EARNED THE ENERGY STAR BY MEETING STRICT ENERGY EFFICIENCY

CRAC Precision climate control units for data centres

The High Performance Floormount Indoor Package Cooling Solution. Precision Cooling for Business-Critical Continuity

Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MF08CESWW. Voltage rating: 115V~60Hz Power rating : 800W

USER INSTRUCTIONS FOR 10 LITRE PORTABLE DEHUMIDIFIER MODEL NO. DHMD102

8W! SILENT-100 Series. 26,5 db BATHROOM EXTRACT FANS. Bathroom and toilet extract fans SILENT-100. Low noise! Water protected! Energy efficient!

saving energy in comfort Factsheet Recair Enthalpy

about your house How to Get the Ventilation That You Need in Your House Figure 1 Infiltration and exfiltration of air in a house

NewAir AC-10000E, AC-10000H Portable Air Conditioner Owner s Manual PLEASE READ AND SAVE THESE INSTRUCTIONS

Energy Efficiency. Bars & RestauRants.

How to choose a heat pump and use it wisely

Airline. small air handlers and extract fan units. VES Airline part of a complete range of innovative, flexible products from the HVAC experts

Défumair XR. ventilation and cmv. fire grade - label CE. smoke-extraction fan extraction casing for kitchen at F advantages.

Daker DK 1, 2, 3 kva. Manuel d installation Installation manual. Part. LE05334AC-07/13-01 GF

CE6500 Energy Recovery Ventilator

KONRAD. Hybrid Fancoil Series

Gree Solar Hybrid Hi Wall Inverter Air Conditioner

CONTENTS 1. IMPORTANT NOTICE 2 2. TECHNICAL SPECIFICATION 3 3. OPERATION DETAILS 4 4. WIRING DIAGRAM EXPLOSION VIEW 12 6.

Lesson 36 Selection Of Air Conditioning Systems

DIESEL-FUELED, BLOWN AIR, DUCTABLE HEATERS

Delivering exceptional performance and Ecovalue. Ecocent

SWIMMING POOL AIR-HANDLING UNITS KU-DB Series

FLAT TECHNICAL DATA. HEAT RECOVERY VENTILATION UNITS for RESIDENTIAL BUILDINGS. indoor air quality and energy saving ENERGY CLASS B A A B A A UNIT

RKE. Heat recovery unit. heat recovery unit RKE. from 200 to 6800 m 3 /h. General features

Supplying. your home with. Our wall-mounted ventilator range: flexible, powerful ventilation technology for a healthy environment.

Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MM14CCS. Voltage rating: 115V~60Hz Power rating : 1400W

RDJ10RF/SET. Wireless room temperature controller with 24-hour time switch and LCD. Programmable, for heating systems

Under sill units. Type FSL-B-ZAS

AIR CONDITIONING EFFICIENCY F8 Energy eco-efficiency opportunities in Queensland Foundries

Key energy-efficient features of your new home

Mistrale. Fusion Terminal

Drayton Digistat +2RF/+3RF

Topvex SX/C, Topvex TX/C. Air Handling Unit

SAVE ENERGY AT HOME INSULATE AND AIR SEAL

ENHANCED LABORATORY HVAC SYSTEM

BLACK TIE. Instructions Manual

HRU ECO 4. System 4 Continuous Mechanical Supply and Extract Ventilation with Heat Recovery Appendix Q Eligible

Portable Air Conditioner

Variable Air Volume - VAV

Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MN12CES / MN10CESWW

CONTENTS 1. IMPORTANT NOTICE 2 2. TECHNICAL SPECIFICATION 3 3. OPERATION DETAILS 4 4. ELECTRICAL SCHEMATIC DIAGRAM EXPLOSION VIEW 16 6

CoolTop. A unique water cooled air-conditioning unit for server room cooling from the top AC-TOPx-CW-240/60

Solar Homes Catch the Sun. Are you planning a new house? Discover how you can apply solar architecture principles to:

OPERATION MANUAL. Total Heat Exchanger HRV (Heat Reclaim Ventilation) (Ceiling mounted duct type)

Heat Recovery based on Exhaust Air

HEATER, AIR CONDITIONING AND VENTILATION

york air-conditioning products Residential & VRF News 2015

4 Alarm and info. Alarm. Yes Warning. No Information No Reset alarms > No Current list > Alarm log list > Delete alarm log > No

HVAC Costs. Reducing Building. Building owners are caught between two powerful forces the need to lower energy costs. By Stephen J.

Basics of HVAC Cleaning

Knürr CoolAdd The universal retrofit solution against overheating in server racks. Rack & Enclosure Systems

Air Conditioners Technical Data

EFA PSBP. Natural Ventilation Strategy. Introduction. 1.1 Relevant legislation The Building Regulations 2010

101 Low-Cost /No-Cost. Home Energy-Saving Measures

How To Get A Passive House

INFRARED QUARTZ WALL HEATER

Indoor coil is too warm in cooling mode or too cold in heating mode. Reversing valve or coil thermistor is faulty

NewAir AC-10100E / AC-10100H Portable Air Conditioner Owner s Manual PLEASE READ AND SAVE THESE INSTRUCTIONS

Climasys Thermal Management System. Schneider Electric Universal Enclosures 2009

USER S INFORMATION MANUAL

SPECTRACOOL AIR CONDITIONERS PENTAIR EQUIPMENT PROTECTION MCLEAN IS NOW HOFFMAN COOLING

Transcription:

Flexit SPIRIT K2R Air handling unit with integrated kitchen hood The quietest on the market Modern design Energy-efficient Installation in the kitchen Flexit SPIRIT - a new generation of air handling units for homes.

Functional design Flexit SPIRIT K2 is available in white and silver. A separate volume part in glass and metal for installation below the unit is supplied with the product. The volume part ensures extremely good odour absorption. The product can be installed without the volume part. Separate mouldings must be ordered. See accessories. Control panels To go with the new unit, you can choose between the CI and CI 0 control panels. CI control panel The CI control panel has all the necessary control functions. It is possible to adjust and control speed and temperature on the panel. The panel gives a signal if there is a fault in the unit or the filter needs changing. The panel is the right size to fit a single wall box and comes with a low-voltage cable for connection to the unit. Several panels can be connected if ventilation needs to be controlled from several places in the dwelling.. CI 0 control panel The Flexit CI 0 has lots of extra refinements and control options. In addition to the standard functions on the CI, the CI 0 has the following features: Timer function High-resolution colour display with text and symbols Cooling control Extract air control The panel displays indoor and outdoor air temperature. Functions and alarms appear on the display with help messages. The panel is the right size to fit a single wall box and comes with a low-voltage cable for connection to the unit. If ventilation needs to be controlled from several places in the dwelling, a CI panel and wireless forcing switch can be used. Cleaning and filter changes Changing the filters regularly and cleaning the fans ensure that the air handling unit works optimally. Cleaning is simple if you follow the description in the user manual. The fat filter in the kitchen hood absorbs fat and food odours from food preparation. The fat filter must be cleaned regularly and can be cleaned in a dishwasher. The air handling unit has two filters that filter out outdoor pollution and protect the rotor from dirt. Filters must be replaced as required, once or twice a year. Filter replacement is easy. Open the front and change to a new filter. With a Flexit filter subscription, filters are sent directly to the address you specify. Read more about filter subscriptions at www.flexit.no. The filters for the air handling unit are easily accessible and can be easily replaced. 2

Requirement-controlled ventilation the right amount of air at the right time In addition to high efficiency and low SFP, energy-efficient ventilation is also about supplying the right amount of air at the right time. Flexit s new automatic control system has been developed to make it easier to operate the user interface correctly It is also possible to use a number of control options such as timer, CO2, pressure, humidity and the presence of people to automate ventilation so as to ensure a good indoor environment and low energy consumption. Key to the colour codes used in the ventilation system: Extract air. Contaminated air is removed from wet rooms, bathrooms and toilets. Supply air. Filtered, conditioned air is supplied to bedrooms and living rooms. Exhaust air. Contaminated air is expelled from the house. Outdoor air. Clean, fresh air is drawn in from outside. CI (09410) or CI0 (09415) (advanced) in a separate location in dewelling for simple control and monitoringof the ventilation systemt. K2R in apartment: C02-sensor Wireless control panel Motion sensor (09390) in living room sends a signal to the unit to increase ventilation to max setting Bedroom CO2-sensor ( 110991) in living room sends a signal to the unit regarding the contamination level in the room. Ventilation is adjusted as required Living room Bedroom Bathroom/ toilet Hall Kitchen open solution Wireless control panel (110983) for forcing (max) ventilation. It can be positioned near the bathroom for accessibility. Simple retrofitting without laying cables. Humidity sensor (110987) in bathroom and wet room sends a signal to the unit regarding the humidity level in the room. Ventilation is adjusted as required. Humidity sensor Motion sensor Air handling units in a separate room. It is equipped with low-enery fans, a high-efficiency rotor recovery system and fine filters. the control system regualtion as required. Fireplace requires an adequate air supply to ensure a good updraught and prevent smoke from coming into the room. Wireless control panel (110983) for increasing the air supply if a fireplace is used. It can be positioned near the fireplace for accessibility. Simple retrofitting without laying cables See www.flexit.com for more information. Requirement-controlled ventilation the right amount of air at the right time Requirement-controlled ventilation means that ventilation in the building can be controlled in such a way that the needs of the occupants are properly catered for and the building is ventilated well enough to prevent possible damage. 3

Product description (Left model shown. The right model is inverted.) Flexit SPIRIT K2R is an air handling unit with a rotating heat recovery system and integrated kitchen hood. The product is installed in the kitchen above the hob and is suitable for new and existing flats, studio flats, terraced houses and small detached houses. The unit is available with AC or EC fans. The unit has two F7 compact filters. 3 2 Outdoor Supply Extract Exhaust air air air air 4 1 7 The supply air passes via ducts and valves to living rooms and bedrooms. The extract air is extracted either from the same room or via door gaps/overflow gratings to toilets and wet rooms. The used air passes via the duct system back to the unit, emits heat and is blown out of the building via a roof hat, combi-box or wall grating. 8 5 6 12 Flexit SPIRIT K2R is fitted with an efficient rotating heat recovery system. The rotor unit has a high efficiency and meets the heating requirements for the ventilation air for most of the year. The cold outdoor air passes through one half of the rotor and the warm extract air passes through the other half. With this principle, a large part of the heat in the extract air will be transferred to the supply air. Spirit K2 is designed with a pressure fan for supply air and a suction fan for extract air to avoid odour transfer. Both extract air and supply air are filtered so that pollution does not come into contact with the rotor material. The moisture in the extract air accompanies the air out in the exhaust duct and out of the building. The rotor technology does not require condensation drainage. This means simpler installation. The unit has an electronic control that automatically switches the recovery function off/on in relation to the outdoor temperature. If the outdoor temperature is extremely low, a heating element will ensure that the supply air has the desired temperature. When there is no need for recovery (for example in the summer), the rotor will stop. Flexit SPIRIT K2R is fitted with electronic automatic control which is controlled from a separate CI or CI 0 control switch. There is simple adjustment of speeds for both AC and EC fans. 9 General view (rotary wheel heat exchanger) 1 (FI2) Extract air filter F 7 2 (FI1) Supply air filter F 7 3 (EB1) Heating element 4 (F10-20) Overheating thermostat (Reset) 5 (M1) Supply air fan 6 (M2) Extract air fan 7 (HR-R) Rotary wheel-type heat exchanger 8 (M4) Rotor motor 9 Control unit 10 Kitchen hood 11 Adjustment switch 12 Damper adjustment 11 10 Switches for operating the kitchen ventilation and light are easily accessible at the front. The integrated kitchen hood has switches for the damper and forcing and a pushbutton for lighting. The damper is opened during food preparation by turning the switch. When the switch is at level 1, the damper will be half open. When the switch is at level 2, the damper is fully open. When the switch is at level 3, the unit will increase the air flow rate to 3 (forced ventilation). The switch must be turned back manually (after food preparation). To avoid the rotor getting dirty, cooking fumes bypass the rotor recovery system. 4 Flexit Spirit K2R seen from below. The fat filter and glass for the compact fluorescent tube can be easily detached.

Flexit SPIRIT K2R Art.no. Type EC-fans (Low-energy fans) 700014 K2 RER EC W right mod. white, EC-fan 700015 K2 RER EC S right mod. silver, EC-fan 700016 K2 REL EC W left mod. white, EC-fan 700017 K2 REL EC S left mod. silver, EC-fan AC-fans 700010 K2 RER AC W right mod. white, AC-fan 700011 K2 RER AC S right mod. silver, AC-fan 700012 K2 REL AC W left mod. hvit, AC-fan 700013 K2 REL AC S left mod. silver, AC-fan Control panels CI Control Panel must be selected. CI or CI0 specified when order a unit. CI 0 Art.no. Type 09410 CI Control panel 09415 CI 0 Control panel, with timer function If you want to control the unit from multiple locations, order extra control panels. Accessories Art.nr. Type 12767 Filter set, F7/F7 111577 Filter, F7, hybrid (carbon-coated) 102194 Filter for kitchen hood, 400xmm 110983 Forcing switch, wireless (complete set) 111293 Additional forcing switch 09390 Motion detector SP 450 09861 Fire- smoke detector 110991 CO2 -sensor 110987 Humidity sensor 09862 Damper for ventilation throug kitchen hood Filter set (F7/F7) Forcing switch, wireless, complete set Filter, kitchen hood Motion detector 001 Combi. Unit, hvit (2x125mm) 002 Combi. Unit, black (2x125mm) Kitchen hood without vol.glass 110058 Profil list, white 110059 Profil list, silver For top cabinet below 700mm 110056 Film for side, whitet 110057 Film for side, silver Duct covers When duct goes stright up. Covers height 215-3mm. 09863 Duct cover, white 09864 Duct cover, silver When duct goes to the side. Covers height 215-3mm. 09865 Duct cover, white 09866 Duct cover, silver Fire-/smoke detector CO2-sensor Humidity sensor Damper Combi. Unit Profil list Film Duct cover, Duct cover, open 5

Technical data K2R AC K2R EC Rated voltage 230 V/50 Hz 230 V/50 Hz Fuse 10 A 10 A Rated current, total 3.7 A 3.9 A Rated power, total 846 W 870 W Symbols Used These products have a number of symbols that are used to label the product itself and in the installation and user documentation. SUPPLY AIR EXTRACT AIR Rated power, electric batteries 700 W 700 W Fan power 2 x 62 W 2 x 74 W Rated power rotor motor 3 W 3 W Fan type B-wheel F-wheel Fan motor control Transformer 0-10 V Max. fan speed 2500 RPM 1970 RPM Automatic control standard CS CS Filter type (SUP/EXTR) F7/F7 F7/F7 SUP filter dimensions (WxHxD) 130x335x50 mm 130x335x50 mm EXTR filter dimensions (WxHxD) 130x335x50 mm 130x335x50 mm Weight 56 kg 56 kg Duct connection Dia. 125 mm (sleeve) Dia. 125 mm (sleeve) Height (without glass screen and bosses) * 700 mm 700 mm Width 598 mm 598 mm Depth (including glass screen) * 510 mm 510 mm EXHAUST AIR OUTDOOR AIR Lighting, compact fluorescent tube 11 W/G23 11 W/G23 * See dimensioned drawing on next page. EXAMPLE OF NIPPLE LOCATIONS (shown as a right model) Temperature efficiency (according to EN 308) 100 % 40 20 0 0 100 400 [m 3 /h] www.flexit.no Here it s possible to download FlexitCalculation. This is a calculation program for air handling units that make it easier to find the best unit. There are dimentioned drawing and 3D-models of the units and all technical values of the products. It can be removed files for use in other applications, eg. MagiCAD. 6

System drawing Outdoor air Supply air Extract air Exhaust air System drawing (electric battery) B1 B1 EB1 Supply air temperature sensor Heating element F10 Overheating thermostat, manual reset FI1 EB1 F10 FI2 F20 FI1 Overheating thermostat, automatic reset Supply air filter F20 FI2 Extract air filter M1 Supply air fan HR-R M4 M2 Extract air fan HR-R Rotary wheel-type heat exchanger M1 M2 M4 K Rotor motor Kitchen hood DA4 Damper DA4 K Dimensioned drawing 371 84 (Shown as a left model) 371 84 (Shown as a right model) 229 229 129 129 227 227 514 514 7

Capacity diagram, sound data, specifications - K2R AC Supply air side (with F7 filter) l/s 0 20 40 400 Contact resistance (Pa) 100 Pa 0 230V 190V 170V 150V 230V 120V 190V 105V 170V 85V 150V V 120V 105V 85V V db(a) 65dB(A) 70dB(A) 55dB(A) 50dB(A) 40 20 Power consumption in Watt 0 W Yellow field: SFP < 1.0 per fan m 3 /h 0 100 Air flow rate, m 3 /h - Pressure correction factor Extract air side (with F7 filter) l/s 20 0 40 400 Contact resistance (Pa) 100 Pa 0 230V 190V 170V 150V 120V 105V 85V V V 230V 190V 170V 150V 120V 64dB(A) 105V db(a) 85V 55dB(A) 45dB(A) 50dB(A) 40 20 Power consumption in Watt 0 W Yellow field: SFP < 1.0 per fan m 3 /h 0 100 Air flow rate, m 3 /h - Pressure correction factor Sound data is given at sound power level LwA in the capacity diagrams and is corrected with the table below for the various octave bands. Radiated noise produces Lw in the various octave bands and total LwA. Radiated noise is calculated by taking the noise value from the supply air table and deducting the total value from the correction factor table. Correction factor for Lw Hz 63 125 250 500 1000 0 4000 00 LwA Supply air 4 5 5-2 -12-15 -21-41 Extract air 9 10 5-5 -16-14 -26-45 Radiated -46-39 -29-36 -40-44 -54-58 -33.5 8

Capacity diagram, sound data, specifications - K2R EC Supply air side (with F7 filter) l/s 0 20 40 400 Contact resistance (Pa) 100 Pa 0 100% % % 40% 100% % % 40% 65dB(A) db(a) 55dB(A) 70dB(A) 40 20 Power consumption in Watt 0 W Yellow field: SFP < 1.0 per fan m 3 /h 0 100 Air flow rate, m 3 /h - Pressure correction factor Extract air side (with F7 filter) l/s 0 20 40 400 Contact resistance (Pa) 100 Pa 0 100% % % 40% 100% % % db(a) 63dB(A) 40% 50dB(A) 55dB(A) 45dB(A) 40 20 0 W Power consumption in Watt Yellow field: SFP < 1.0 per fan m 3 /h 0 100 Air flow rate, m 3 /h - Pressure correction factor Sound data is given at sound power level LwA in the capacity diagrams and is corrected with the table below for the various octave bands. Radiated noise produces Lw in the various octave bands and total LwA. Radiated noise is calculated by taking the noise value from the supply air table and deducting the total value from the correction factor table. Correction factor for Lw Hz 63 125 250 500 1000 0 4000 00 LwA Supply air 14 7-2 -5-3 -13-18 -33 Extract air 15 9 0-3 -8-11 -19-36 Radiated -41-35 -33-39 -40-49 -50 - -33.5 9

Flexit the safe choice! Flexit specialises in home ventilation and delivers clean, fresh air solutions for a healthy indoor environment. Flexit is the market leader in home ventilation and has been supplying ventilation solutions to Norwegian homes for 35 years. Flexit is a Norwegian company. All products are developed specially for the Nordic climate. Products are tested and documented in accordance with the latest standards. That gives you peace of mind! The SPIRIT range a new generation of air handling units from Flexit Flexit s new SPIRIT range is a brand new generation of air handling units. Stricter energy requirements in the regu lations and the new Passive House Standard demand efficient air handling units, and the SPIRIT range has been developed to meet that need. High targets for energy efficiency, quietness, user friendliness and quality characterise the whole range, and new models will be introduced in the future. All the models are equipped with high-effi ciency rotating recovery systems and have low-energy fans. Together with the new control system, this means that the SPIRIT range sets a new standard in home ventilation. Flexit K2R It is a combined air handling unit with an integrated kitchen hood, specially designed for flats. It has a high-efficiency rotary recovery system and low-energy fans. The unit is very quiet. Flexit UNI 3 Air handling unit with a capacity of around 400 m 3 /h. It has a high-efficiency rotary recovery system, low-energy fans and a new control system. De signed for small dwellings, single-family houses, small office buildings and passive houses. Flexit UNI 4 New air handling unit with a capacity of 6 m 3 /h. It has a high-efficiency rotary recovery system, low-energy fans and a new control system. Design for bigger homes, small office buildings and passive houses. SINTEF, working together with Flexit, has developed optimal technological solutions with the emphasis on energy efficiency and good indoor environment. The Norwegian Design Council, working together with Flexit, has conducted user surveys to ensure optimal user friendliness. Hareide Designmill has assisted Flexit with design development. EE products (electrical and electronic products) Flexit meets its obligations under the Waste Regulations/ EE Regulations through its membership of the following waste recycling company El-retur AS EE waste must not be disposed of with other waste, but when no longer needed should be handed into a dealer or appropriate location at a local dispos al/collection centre. Since 5 EE products have been labelled with a crossed-through waste bin and are part of a return and recycling system where they are accepted free of charge. Our products are subject to continuous development and we therefore reserve the right to make changes. We also disclaim liability for any printing errors that may occur. Product code 111208 08/2011 Phone +47 6981 0000 Fax +47 6981 00 info@flexit.com - www.flexit.com 10