Emissions... VCE Emission Test Chambers. to Characterize Volatile Organic Compounds - VOC



Similar documents
Solar energy Solar technology in endurance testing

VTS³ and VCS³ Stress Screening Systems. More Power for Maximum Quality Assurance

Vacuum drying oven for non-flammable solvents

Material test chamber with mechanical convection

Product-friendly and fast...

Climate Test Chamber. System Weiss. Type WK3-2000/40

Incubator with mechanical convection

With high speed to top quality

Heating oven with mechanical control

Climate chamber with illumination

TECHNICAL SPECIFICATION. StirLIN-1 Economy Liquid Nitrogen System

Heating oven with mechanical convection

Perfection in per formance, equipment and design

VDL 53 - Vacuum drying oven for flammable solvents

Digital inductive conductivity transmitter

Weiss Mobile Air Conditioning Systems

LABOKLAV. Autoclaves Made in Germany.

Visions become real. Temperature control and cooling systems. The innovative and reliable solution

AVL FUEL MASS FLOW METER & FUEL TEMPERATURE CONTROL

Duct Humidity Transmitter

ECOCIAT. Domestic hot water heat recovery unit


How To Make A Fronius Cl Power Inverter

Incubators, cooled incubators, drying ovens, sterilizers, climatic chambers

Refrigeration Compressed Air Dryer Buran Ultrapulse

Kompressoren. Adsorption Dryer AD

Environmental Chamber. Stability/ GMP 2000 Series. Stability Testing Chambers

Thermal environments. Tel

Transformerless PV inverter withstandardsystem monitoring. Fronius IG TL

Eurovacuum EV Series. Single Stage Oil Sealed Rotary Vane Pump

USER INSTRUCTIONS FOR 10 LITRE PORTABLE DEHUMIDIFIER MODEL NO. DHMD102

HVAC units for tramways, trains and metros Proven performance, high reliability and low life cycle cost

RDJ10RF/SET. Wireless room temperature controller with 24-hour time switch and LCD. Programmable, for heating systems

OT 40L / 90L. Laboratory Steam Sterilizers

STERILIZERS, LABORATORY DRYING OVENS

EuroFID Total Hydrocarbon Analyzer. Precise Determination of Total Hydrocarbons in Air for Corrosive as well as Condensing Gases

ATL Fuel Level Sender Probes

Electric Flow Boiler

HIGH PRESSURE TECHNOLOGY HYDRAULICS PNEUMATICS TESTING EQUIPMENT

HDA

3.1.1 Full Type Tests & Routine Tests according to Clause 8 2 & Instructions For Installation, Operation & Maintenance

SWIMMING POOL AIR-HANDLING UNITS KU-DB Series

clean and quiet dental

DC UPS. RTB.e A. IMB.e/ITB.e kva. E2001.e/E3001.e kva. Input voltage: 110/125/220 Vdc. 115/120/230 Vac, 1-phase (IMB.

STD - STANDARD VERSION extended possibilities reasonable price wide range of optional equipment

Silicagel-water adsorption cooling prototype system for mobile air conditioning

ABB i-bus EIB / KNX Analogue Input AE/S 4.2

MTI10 Insertion and MTL10 In-line Thermal Mass Flowmeter and Temperature Transmitter

CRAC Precision climate control units for data centres

Clinic Washer-Disinfectors. Washer-Disinfector Line

DIESEL-FUELED, BLOWN AIR, DUCTABLE HEATERS

ADU 5. Automatic Distillation Unit

Lightweight, compact, ergonomic, safe POLARIS FID. Portable TOC Analyser for Stack Emissions

Daker DK 1, 2, 3 kva. Manuel d installation Installation manual. Part. LE05334AC-07/13-01 GF

Kompressoren. Oil Water Separators OWS

RRV934. Multi-controller. Synco living

DRYPOINT AC HP PREMIUM HIGH-PRESSURE DRYING

Technical Information RIA14

HEAT MONITORING AND CONTROL INSTRUMENTS FOR TRANSFORMERS MB 103 TEMPERATURE CONTROL UNIT PT 100 TEMPERATURE SENSOR

T0118 T2118 T3118. Instruction Manual

CHROMOCTANE O N LINE ANALYZER

Weighing terminals IP69K GMP EHEDG NSF. Precision in stainless steel Easy to clean perfect hygiene

450TOC Analyzer. Portable, Real-time, Continuous Total Organic Carbon Measurement. 450TOC Analyzer

Electronic pressure switch with display Model PSD-30, standard version Model PSD-31, with flush diaphragm

LyoBeta. R+D Freeze-Dryers

Tools & Equipment Robinair

Liebert Hiross HPW The High Performance Wallmount Cooling Solutions for Telecom Mobile Remote Access Nodes

Type: EASY719 DC RC Article No.: Ordering information Relay outputs Quantity 6 Power supply V DC 24 V DC. Description

Long sensing range. Most suitable for conveyor lines and parking lot applications. 10 m ft (Red LED)

High-efficient gas boiler CompactGas

INNOVATIVE SOLUTION OF DOMESTIC HEATING SPLIT TYPE SPLIT DHW INTEGRATED TYPE MONOBLOC TYPE

Spetec. Laminar Flow Box. Portable Clean Room Technology

HALT and HASS. Test Equipment For Highly Accelerated Life Test and Stress Screen Applications

Test equipment for temperature and its reduction

Current valve. for AC 24 V pulse/pause control of electrical loads up to 30 kw

Power consumption (kw)

CoolTop. A unique water cooled air-conditioning unit for server room cooling from the top AC-TOPx-CW-240/60

Digital pressure gauge for industrial applications Model DG-10-S, Standard version Model DG-10-E, Enhanced version

Online Infrared Flue Gas Analyzer Gasboard 3000

industry revolves around

LABORATORY / MEDICINE / PHARMACEUTICAL REFRIGERATORS

Hydraulic control unit series

ABB i-bus KNX Fan Coil Actuator, MDRC FCA/S 1.1M, 2CDG R0011

CE6500 Energy Recovery Ventilator

Power Supply Systems. Performance guaranteed. Power Supply Systems single-voltage UIC-systems multi-voltage UIC-systems

COMBIMASS. Technical Data COMBIMASS eco-bio +

heat treatment equipment & accessories

TECHNICAL DATA E-PRO COLD UNITS Refrigerated glass display units, CDDL, CDD and CDDH series

Operating Manual UWAPS-TINY Series

ELEKTROTEHNI KO PODJETJE Leskoπkova cesta 12, 1000 Ljubljana, SLOVENIA

Freezers - Ultrafreezers. Platilab & Irilab Series

CATHODIC PROTECTION TRANSFORMER RECTIFIER (CPTR)

Rotary screw compressors kw 5,5 7, , bar MODULO

Pressure transmitter For general industrial applications Model A-10

Multi-Range Programmable DC Power Supplies 9115 Series

Blood Bank Refrigerators according to DIN Blood Plasma Freezers according to DIN 58375

DIESEL-FUELED, BLOWN AIR, DUCTABLE HEATERS

Cross-beam scanning system to detect slim objects. 100 mm in

data sheet DONATELLO Rev. I emiss - 25/10/ PRO03 code Automatic tissue processor DONATELLO

Computer Controlled Generating Stations Control and Regulation Simulator, with SCADA SCE

Transcription:

Emissions... VCE Emission Test Chambers to Characterize Volatile Organic Compounds - VOC

Environmental test equipment to characterize... Materials can be affected by environmental influences. However, under these influences, the materials can be harmful to the environment also, e.g. by emissions from the materials into the air. These emissions are particularly relevant in closed rooms. They can affect other available materials and of course also human beings. The relevant factors and their effect on the emission behaviour of materials in connection with suitable measuring methods can be used to evaluate emission together with the Vötsch chamber. Analytical investigations, system calibration and olfactometric studies are possible with suitable measuring equipment. Volatile organic compounds (VOC) from indoor materials and products are determined under practical conditions. Scientific measurement and product testing aimed to limit organic emissions indoors, for the purpose of improved consumer protection, can be evaluated. Exposure to indoor air pollution caused by volatile organic compounds (VOC) must be further reduced resp. indoor air quality improved - for several reasons: l Increased sensibility of the human organism to the influence of minute concentrations Requirements/fulfilment l Modern people spend about 90 % of their time indoors 2 l An increased use of polymer hydrocarbon compounds in indoor materials and products results in a growing number of emitting sources l Energy saving insulation reduces the ventilation rates in buildings which leads to an accumulation of pollutants indoors l Reduction of the environmental pollution of technical devices (greenhouse effect, ozone layer depletion) The technical requirements of the environmental test equipment were defined by specialists from industry and science and then successfully put into practice: l A test equipment with a low emission (purity in molecular range) l Excluding contaminations from the vicinity l Particle measurement l Minimizing adsorption effects l High desorption temperatures ( > 200 C) l High parameter accuracy l Ventilation l Tests with and without air exchange l Standard analytical equipment can be used l Networking and documentation possible Two emission test chambers with standard test space sizes of 200 and 1000 litres are available. An ideal practically oriented solution. Special sizes on request.

... volatile organic compounds Possible fields of application Following investigations can be conducted with suitable measuring equipment Testing of all consumer products and materials indoors, passenger cars, electronic equipment, varnish, dyes, modern objects of utility and all types of clothing. l Qualitative analysis l Quantitative analysis l Adsorption effects analysis of the walls l Recovery rates analysis l System calibration l Olfactometrie Application in many branches... l Test houses and research l Automotive industry l Electronics industry l Aviation and space industries l Plastic processing industries l Clothing industry, manufactures of sports articles l Chemical industry l Paints and coatings l Building material industry 3

Test Standards Extract of trade specific test standards / test methods l l l Automotive industry e.g. VDA 276, GS 97014-2... Building materials, interior fitting items, furniture e.g. ISO 16000-9... Building products, furnishings e.g. pren 13419-1... l Electric devices, electronic equipment, HiFi, TV, Video, DVD,... e.g. ECMA-328... l l l Floor coverings, interior fittings, furnishings e.g. pren 15052, GEV... Wood-based products e.g. ASTM D... Interior fitting, furnishing e.g. ASTM D... 4

... Technical Data Basic equipment l Test space stainless steel, electro polished and pressure proof to ± 10 mbar l Air-jacket conditioning l Carrier gas conditioning for climate l Carrier gas massflow control via massflow controller l Desorption and rinsing procedure l Special ventilation with a dry mounted magnetic clutch l Connection for discharging quantities of gas for analysis l Entry port septum l Water storage container (humidification water) of stainless steel with automatic water replenishment l Microprocessor control and monitoring system l Colour touchpanel Options and user-specific solutions on request. Technical Data Type VCE 200 VCE 1000 Test space volume (useful) l 240 (208) 1000 (916) Carrier gas purified compressed air, on-site Performance range for temperature testing Conditioning air jacket principle Temperature range C +20 to +130 Temperature deviation in time 1) K ±0.1 to ±0.3 Temperature homogeneity in space 2) K ±0.5 Temperature rate of change 3) Cooling K/min 0.3 0.3 Heating K/min 1.0 0.4 Performance range for climate testing Conditioning Carrier gas conditioning with climatic modul with evaporation system Temperature range C +20 to +130 Humidity range % 5 to 95 Dew point range C +5 to +60 Humidity deviation in time % ±1 to ±3 Carrier gas exchange rate 0.1 to 1.8 chamber volume per hour Conditions of carrier gas min. +10 C / 50 % RH max. +32 C / 80 % RH Performance range for desorption Temperature of desorption up to max. +240 C, adjustable Test space surface temperature between +220 C and +240 C Rinsing procedure max. 4 m 3 /h Dimensions test space Width mm 610 750 Depth mm 610 1630 Height mm 560 750 Test space door mm 530 x 520 670 x 670 External dimensions Width mm 1250 1350 Depth mm 1700 2950 Height mm 2350 2050 Sound pressure level 4) db(a) 61 63 Rated power kw 9,0 10,0 Electrical connection 3/N/PE AC 400 V ± 10 %, 50 Hz Admissible ambient conditions: temperature +15 C to +35 C, humidity max. 75 %, max. dew point +20 C - 1) measured in the middle of test space, 2) relative to the set value, 3) in accordance with IEC 60068-3-5, 4) measured 1 m distance from the front and in 1.6 m height at free field measurement according to EN ISO 11201. We reserve the right of changes in construction resulting from technical progress. Some of the illustrated systems contain optional extras. 5

Comfortable, user-friendly operation... Computer Integrated Control Our test chambers are equipped with an integrated industrial computer system with a 8" colour touchpanel to facilitate operation, monitoring and documentation. Control is governed by the 32 Bit I/O system with integrated soft PLC. A web server can place test and diagnosis information in the intranet via Ethernet if desired. Online-Service The units have an online service function, enabling our specialists to establish an online data link to the unit via internet or mobile telephone. The online link provides our experts with all the data they require. Remote control and monitoring Safe operation of the overall system requires the test cabinet to be reliably integrated. Enables, warning messages and fault signals are defined in a safety matrix with the customer and the safety officers. Units can be reached and controlled from practically anywhere in the world by simply accessing the unit webserver in the intranet via the network or enabling in the internet. Networking Compatible with S!MPATI* software package Technical Data l Touch screen 800 x 600 pixel l Multilingual software Interfaces l Ethernet 100/10 megabit l RS 232 (Option) l USB for stick Customer inputs/outputs l 4 potential-free outputs for test specimen control l 4 inputs (24 V DC) Options Additional measuring technology l Independent temperature and humidity measuring USB-Stick l For external saving of measuring data Our software S!MPATI* dictates the optional operating parameters for system and test samples. This software, just like known Windows standards, can also be integrated into networks. Operation of the test system is simple and time-saving. Integrated monitoring routines makes for more reliable system operation. The evaluation and documentation of test cycles as well as the integration of special measuring data guarantees a higher quality standard. 6

... Examples for application VCE 200 Ascertaining volatile organic emissions VOC from small assemblies, samples, etc. for interior components of motor vehicles Test space volume 200 litre Temperature range +20 C to +130 C Humidity range 30 to 95 % RH Desorption +240 C including equipment package to Test methods Automotive l Globe valve l Reinforced test space container ±0.1 bar l Optimized cooling and heating performance l Volume compensation Tedlar-bag l FID measuring gas extraction / feed back l Adjustable circulating air quantity VCE 1000 classic Ascertaining volatile organic emissions VOC from interior components of motor vehicles, door coverings, dashboards, head covering Test space volume 1000 litre Temperature range +20 C to +130 C Humidity range 30 to 95 % RH Desorption +240 C including equipment package to Test methods Automotive l Globe valve l Reinforced test space container ±0.1 bar l Optimized cooling and heating performance l Volume compensation Tedlar-Bag l FID measuring gas extraction / feed back l Adjustable circulating air quantity 7

Examples for application... VCE 1000/S Ascertaining volatile organic emissions VOC from interior components of motor vehicles Test space volume approx. 1000 litre Temperature range +20 C to +130 C Humidity range 30 to 95 % RH Desorption +240 C including equipment package to Test methods Automotive l Globe valve l Reinforced test space container ±0.1 bar l Optimized cooling and heating performance l Volume compensation Tedlar-Bag l FID measuring gas extraction / feed back l Adjustable circulating air quantity and additional Emission analysis of energy storages, accumulators,... l Highly modified test space container with special entry ports l Connection to energy storage tester l Customised Safety device energy storage Further additional accessories l Distribution system for taking samples l Adjustable circulating air quantity l Measuring sensor for humidity measurement l Emission-free port hole with external located socket 8

... Examples for application VCE 5000/S Ascertaining volatile organic emissions VOC from motor compartment of a motor vehicle Test space volume approx. 5000 litre Temperature range +20 C / +130 C Humidity range 30 to 95 % RH Desorption +240 C including equipment package to Test methods Automotive l Globe valve l Reinforced test space container ±0.1 bar l Optimized cooling and heating performance l Volume compensation Tedlar-Bag l FID measuring gas extraction / feed back l Adjustable circulating air quantity and additional Ascertaining VOC from motor compartment, complete engine block with gearing (and tank) l Safety device for avoiding an explosion l Safety concept with external sensors l UEL-monitoring for air jacket system l Measuring sensor with intrinisically safe measuring circuit Further additional accessories l Insert cabinet with reinforced floor load 850 kg l Distribution system for taking samples l Equipment for uninterrupted power supply 9

Examples for application... VCE 8000/S Ascertaining VOC from interior equipment (furniture, office equipment) and electric / electronic equipment of a bureau (printer, PC,...) Test space volume approx. 8000 litre Temperature range +20 C to +130 C Humidity range 30 to 95 % RH Desorption +240 C including equipment package to Building materials ISO 16000-9 Electric devices ECMA l Increased carrier gas exchange rate l Carrier gas conditioning with multi-stage filter unit l Equipment for ozone, particle and very fine particle measuring 10

Emission Test Chambers for Euro VI and better The introduction of the Euro VI and Euro V emission regulations require stringent tests of vehicle emissions. The temperature and climatic controlled SHED chambers from Vötsch comply with the latest European and US standards. Protecting your investment now and in the future SHED chambers for any application RL-SHED to determine the fuel emission of a vehicle while driving. ORVR-SHED to determine the fuel emission while refuelling a vehicle. VT-SHED in accordance with regulations such as CARB, EPA and EU. These chambers are hermetically sealed and use volume compensation bags to accommodate tests at various temperatures without pressure equalisation respective to the atmosphere. 11

Further detailed brochures... Image Brochure Vötsch Minis... VT & VTM... VT 3050 Temperature Laboratory Scope... VT 4011 - VT 7021 VTL & VCL Equipment for Laboratories VT 3 & VC 3 Reproducible Climate Constant Climates VC³ 0... XXL Systems for High Quality High Speed... Stress VTS & VCS Vibration and more VTV & VCV Lightning Speed... Shocktest Chambers Splash Water System VT 0800/S Corrosion Salt spray Air Pollution & Emission VLM Cabinet VBT Cabinet Walk-In Chambers Guaranteed Safety DKD / Calibration Communication... Software S!MPATI* Solar technology in endurance testing Testing Solutions for Automotive Industry EMC Minis VT 4002 EMC Environmental Simulation Beethovenstraße 34 72336 Balingen-Frommern Germany Telefon: +49 (0) 74 33 / 303-0 Telefax: +49 (0) 74 33 / 303-41 12 info@v-it.com www.v-it.com / www.voetsch.info VIT-E 9/7 0M 03.10 N VIT www.dkd-temperatur-feuchte.de