ENrich SEC 70 ENrich SEC 650 High-Resolution Size Exclusion Columns Instruction Manual



Similar documents
INSTRUCTIONS Edition AC

ProteinChip Energy Absorbing Molecules (EAM)

Transforming a ChromLab Software 2-D Purification Template into an Automated Multidimensional (Multi-D) Purification Workflow An Instructional Guide

Image Lab Software for the GS-900 Densitometer

Gel Filtration Standard

Image Lab Software How to Obtain Stain-Free Gel and Blot Images. Instructions

Cell Sorting. S3e Cell Sorter Quick Guide

How To Install A Gel Doc Xr+ Camera On A Computer Or Mouse Or Tv (For A Powerbook) With A Zoom Lens (For An Ipa) With An Iphone Or Ipa (For Mac) With The Zoom Lens

Bio-Gel P Polyacrylamide Gel Instruction Manual

RESOURCE Q, 1 ml and 6 ml RESOURCE S, 1 ml and 6 ml

Computer Specifications

[ Care and Use Manual ]

Application Note. USD 2995 (a) High Throughput Regeneration Study on MEP HyperCel Mixed-Mode Sorbent on ScreenExpert RoboColumns u

Affi-Prep Protein A Matrix Instruction Manual

Foreign Taxes Paid and Foreign Source Income INTECH Global Income Managed Volatility Fund

Method Development for Size-Exclusion Chromatography of Monoclonal Antibodies and Higher Order Aggregates

[ Care and Use Manual ]

Waters Corporation. Waters 2690/5 USER & TROUBLESHOOTING GUIDE

HiTrap Heparin HP, 1 ml and 5 ml

ProteoMiner Protein Enrichment Kits

TECHNICAL BULLETIN. HIS-Select Nickel Affinity Gel. Catalog Number P6611 Storage Temperature 2 8 C

Reporting practices for domestic and total debt securities

Aurum Ion Exchange Mini Kits and Columns. Instruction Manual

POROS CaptureSelect affinity columns for highspeed quantification of IgG Fc fusion proteins

amplification tech Optical Design of CFX96 Real-Time PCR Detection System Eliminates the Requirement of a Passive Reference Dye

Guide to Reverse Phase SpinColumns Chromatography for Sample Prep

[ Care and Use Manual ]

World Consumer Income and Expenditure Patterns

Installation Qualification/Operational Qualification Protocols and Instructions. Experion Automated Electrophoresis Station and Software

Report on Government Information Requests

Appendix 1: Full Country Rankings

[ Care and Use Manual ]

Thermo Scientific SOLAµ SPE Plates Technical Guide. Consistent excellence. for bioanalysis

[ Care and Use Manual ] styragel column. Contents. I. Introduction. II. Installing the Column Bank. III. Preparing Solvent and Samples

Diafiltration: A Fast, Efficient Method for Desalting, or Buffer Exchange of Biological Samples

HiPer Ion Exchange Chromatography Teaching Kit

Configuring DHCP for ShoreTel IP Phones

THE WORLD S LEADING CAR DESIGN MAGAZINE

A Complete Solution for Method Linearity in HPLC and UHPLC

41 T Korea, Rep T Netherlands T Japan E Bulgaria T Argentina T Czech Republic T Greece 50.

An In-Gel Digestion Protocol

Brochure More information from

Data File. Sephadex G-25 media and pre-packed columns. Introduction. Sephadex G-25 Bead structure. Desalting/buffer exchange and gel filtration

Bio-Rad Laboratories. QC data management solutions. Introduce Your Laboratory to a Whole New World of Unity Data Management Solutions

Pore size and BET surface area. analysis at your fingertips. SA Gas Adsorption Analyzer

Report on Government Information Requests

Determination of Calcium and Magnesium in Brine

NI USB-6008/6009 OEM USER GUIDE

What Proportion of National Wealth Is Spent on Education?

To install the I/O Module Board: 1. Remove AC power from decoder.

OCTOBER Russell-Parametric Cross-Sectional Volatility (CrossVol ) Indexes Construction and Methodology

LC-MS/MS Method for the Determination of Docetaxel in Human Serum for Clinical Research

Efficient Multi-Well Protein Purification Strategies

Blue Sepharose 6 Fast Flow

POROS CaptureSelect affinity columns for rapid, small-scale purification and sample preparation of recombinant proteins

IOOF QuantPlus. International Equities Portfolio NZD. Quarterly update

Pall in the Brewery (more value per hectolitre) DE Free Clarification FB1795

Brochure More information from

Supported Payment Methods

Quantum View Manage Administration Guide

Supported Payment Methods

relating to household s disposable income. A Gini Coefficient of zero indicates

High-voltage Differential Probes TMDP THDP THDP P5200A - P5202A - P5205A - P5210A

BT Premium Event Call and Web Rate Card

Report on Government Information Requests

Field Safety Notice Urgent Medical Device Correction C Cloudy Appearance and Potential Tears on System Drapes

Gas Chromatography Liner Selection Guide

Purification of reaction mixtures using flash chromatography.

Motion Graphic Design Census. 10 hrs. motiongraphicdesigncensus.org. 9 hrs.

QIAsymphony RGQ Protocol Sheet

Fast, Reproducible LC-MS/MS Analysis of Dextromethorphan and Dextrorphan

Report on Government Information Requests

Corporate Office Von Karman Ave Suite 150 Irvine, California Toll Free: Fax:

UltraClean Soil DNA Isolation Kit

Determination of Pesticide Residues in Drinking Water Using Automated Solid-Phase Extraction and Gas Chromatography with Nitrogen Phosphorus Detection

Supplies 1. Toner cartridges. Printing. Using color. Paper handling. Maintenance. Troubleshooting. Administration. Index

AG 501-X8 and Bio-Rex MSZ 501(D) Mixed Bed Resin Instruction Manual. Bio-Rad Laboratories, 2000 Alfred Nobel Dr., Hercules CA LIT205 Rev B

Global Effective Tax Rates

Make the invisible visible! SENSORS WITH EXCELLENT BACKGROUND SUPPRESSION

Hong Kong s Health Spending 1989 to 2033

[ Care and Use Manual ]

How To Get A New Phone System For Your Business

Building a Global Internet Company: Driving Traffic to Your Site. Benjamin Edelman Harvard Business School

Cisco 2-Port OC-3/STM-1 Packet-over-SONET Port Adapter

Single-Use Flow-Through Cell ph FTC-SU-HP8

Accuracy counts! SENSORS WITH ANALOG OUTPUT

Size Exclusion Chromatography

Global Economic Briefing: Global Inflation

Accelerated Electrophoresis with Faster Run Times and Increased Sample Throughput

[NUGENESIS SAMPLE MANAGEMENT ] AMPLE IMPROVING LAB EFFICIENCY, ANAGEMENT ACCELERATING BUSINESS DECISIONS. bigstock.com $69

July Figure 1. 1 The index is set to 100 in House prices are deflated by country CPIs in most cases.

Table 1: TSQM Version 1.4 Available Translations

Working Holiday Maker visa programme report. 31 December 2014

MabSelect SuRe. GE Healthcare Life Sciences

A new ranking of the world s most innovative countries: Notes on methodology. An Economist Intelligence Unit report Sponsored by Cisco

Working Holiday Maker visa programme report

The Path Forward. International Women s Day 2012 Global Research Results

Integrating CaliberRM with Software Configuration Management Tools

What Is the Total Public Spending on Education?

MAUVE GROUP GLOBAL EMPLOYMENT SOLUTIONS PORTFOLIO

Transcription:

ENrich SEC 70 ENrich SEC 650 High-Resolution Size Exclusion Columns Instruction Manual Catalog numbers 780-1070 780-1650 Please read these instructions before you use ENrich SEC high-resolution size exclusion media. If you have any questions or comments regarding these instructions, please contact your Bio-Rad Laboratories representative.

Table of Contents Section 1: Characteristics of the ENrich Size Exclusion Columns... 1 1.1 Introduction...1 1.2 The ENrich SEC Separation Media... 1 1.3 Connection to the NGC and Other Chromatography Systems... 2 Section 2 : Use of the ENrich SEC Columns... 3 2.1 Preparation for Initial Use... 3 2.2 Equilibrating and Running the Column... 3 2.3 Sample Considerations... 4 2.4 Sample Elution... 4 2.5 Column Calibration... 4 Section 3 : Care of the ENrich SEC Columns... 6 3.1 Regular Maintenance... 6 3.2 Bed Height Adjustment... 6 3.3 Column Cleaning... 7 3.4 Frit Replacement... 7 3.5 Storage Conditions... 9 Section 4 : Ordering Information...10

Section 1: Characteristics of the ENrich Size Exclusion Columns 1.1 Introduction ENrich prepacked columns for size exclusion chromatography are designed for rapid and reproducible high-resolution separation of biomolecules. Each column contains a unique, high-performance size exclusion media based on spherical polymer beads modified to provide quick, differential size based diffusion. 1.2 The ENrich SEC Separation Media ENrich SEC media is available with different exclusion limits and separation ranges. The prepacked columns contain 10 μm beads, which produce excellent resolution of biomolecules at low backpressures. SEC 70 is ideal for separating biomolecules up to 70,000 Da and SEC 650 is used for larger biomolecules up to 650,000 Da. The 10 μm particle size and narrow particle size distribution provide excellent resolution of biomolecules at high flow rates and with relatively low backpressures. The hydrophilic ENrich media demonstrates extremely low nonspecific binding of biomolecules accompanied by high recovery of biological activity. Stability The columns are stable over the ph range 2 12, allowing easy cleaning and regeneration. ENrich SEC Instruction Manual 1

The ENrich support is compatible with aqueous solutions of 6 M guanidine-hcl and 8 M urea. Detergents and organic solvents such as methanol, ethanol, and isopropanol may also be used. In some cases, alcohols and stability agents such as glycerol may increase the column backpressure. Care should be taken to maintain a flow rate at which the backpressure is below the maximum operating pressure. Table 1. ENrich SEC media and column characteristics. SEC 70 SEC 650 Linear separation range, Da 500 70, 000 500 650, 000 Column dimensions, diameter x height, mm 10 x 300 10 x 300 Column volume, ml 24 24 Nominal particle size, µm 10 ± 2 10 ± 2 Recommended flow rates, ml/min* 0.5 1.0 0.75 1.25 Maximum recommended flow rates, ml/min* Maximum operating pressure 1.5 2.0 600 psi, 4.1 MPa, 41 bar 600 psi, 4.1 MPa, 41 bar Recommended sample volume, µl <250 <250 Efficiency, plates/m >20,000 >20,000 Working ph range 2 12 2 12 Operating temperatures, C 4 40 4 40 * At room temperature. Viscosity may increase at lower temperatures, which will reduce the recommended flow rates. 1.3 Connection to the NGC and Other Chromatography Systems The ENrich columns are fitted with 10-32 type female fittings on either end. Standard 10-32 fittings can be used to plumb the column to a Bio-Rad NGC chromatography system or another vendor s systems. Adaptors are available for connection to systems that use 1/4-28 fittings (catalog # 750-0564). 2 ENrich SEC Instruction Manual

Section 2: Use of the ENrich Columns 2.1 Preparation for Initial Use The column is supplied in 20% ethanol. To remove the storage buffer, pump deionized, filtered water at a flow rate of 0.5 ml/min or less for 30 ml, or just over one column volume (CV). The backpressure will decrease as the ethanol is washed from the column. After this water step you may equilibrate your column as described below. Warning: Do not exceed a maximum pressure of 600 psi (4.1 MPa, 41 bar). 2.2 Equilibrating and Running the Column 1. Always use filtered (0.22 0.45 μm filter) and degassed buffers. This will prolong the life of your column. To avoid bacterial growth, contamination, and poor column performance, use only freshly prepared buffers. 2. Residual ionic charges on the ENrich column are negligible. However, a running buffer with ionic strength of at least 100 mm NaCl is recommended. Phosphate buffered saline (PBS) is an example of a commonly used buffer appropriate for ENrich SEC media. 3. The buffer should contain any cofactors or protease inhibitors previously identified as being essential to maintain enzyme activity. 4. Equilibrate the column with at least 2 CV (~50 ml) of the buffer. 5. Calibrating the column with a gel filtration standard (catalog #151-1901) is an important step for molecular weight determination and for tracking column performance. ENrich SEC Instruction Manual 3

2.3 Sample considerations 1. Always filter (0.22 0.45 μm filter) and/or centrifuge your sample to remove any particulates. 2. In size exclusion chromatography, mass loading is less critical than the volume of the sample. As a general rule, to obtain maximum performance, the sample volume should not exceed 1% of the bed volume (that is, ~0.25 ml for a 24 ml CV) and the sample concentration should not exceed 20 mg protein/ml. Larger volumes can be applied, but resolution may decrease. 2.4 Sample Elution All species within the sample should elute within 1 full CV. The flow rate for optimal resolution depends on sample composition and purity. In general, lower flow rates provide greater performance. Optimal flow rates for both ENrich SEC 70 and ENrich SEC 650 columns are 0.5 1.25 ml/min (see Table 1). 2.5 Column Calibration Use the Bio-Rad size exclusion standards (catalog #151-1901). One vial contains 18 mg of a lyophilized mixture of thyroglobulin (Mr 670,000), bovine γ-globulin (Mr 158,000), chicken ovalbumin (Mr 44,000), equine myoglobin (Mr 17,000), and vitamin B12 (Mr 1,350). 4 ENrich SEC Instruction Manual

ENrich SEC 70 media ENrich SEC 650 media Figure 1. Typical chromatograms for ENrich SEC media. Detection at 280 nm. Absorbance at 280 nm may be greater depending on sample concentration. Time may change depending on flow rate. A. thyroglobin; B. IgG; C. ovalbumin; D. myoglobin; E. vitamin B12. ENrich SEC Instruction Manual 5

Section 3: Care of the ENrich SEC Column 3.1 Regular Maintenance To maintain performance, the column should be stored in 20% ethanol, as described below, for storage periods longer than 2 days. Always run at least one CV of water between 20% ethanol and running buffers. If the column is exposed to air or if air bubbles are trapped in the column. 1. Wash the column in the forward direction with 30 ml of water at 0.25 0.5 ml/min. 2. Wash the column with 30 ml of 20% ethanol at 0.25 0.5 ml/min. Note that the backpressure will increase in ethanol. Do not exceed 600 psi (4.1 MPa). 3. Wash the column with 30 ml of deionized water at the usual operating flow rate as recommended in Table 1. 4. Re-equilibrate the column with the desired buffer. If the column begins to show abnormally high backpressure. If the backpressure increases abnormally, it is likely that the column needs to be cleaned and/or the frit at the top of the bed is clogged. First, clean the column using the method described in section 3.3. If this is not sufficient, replace the top frit as described in section 3.4. 3.2 Bed Height Adjustment Under certain conditions of buffer composition, high flow rates, or long-term use, the resin bed may compress, creating a void between the frit and the top of the bed. Normally, the void can be eliminated by turning the adjusting nut clockwise until the frit just touches the top of the bed. If the bed compresses at high flow rates, stop the pump and loosen the top fitting, then use the adjusting nut to remove the void, retighten the top fitting, and resume pumping buffer. If the bed has compressed from long-term use, replace the top frit as a precaution. 6 ENrich SEC Instruction Manual

3.3 Column Cleaning Careful preparation (especially filtration) of the sample and the buffers will maintain the column s performance and extend its lifetime. Normally, washing with a few CV of running buffer with an ionic strength of at least 100 mm NaCl will remove most contaminants. However, if there is a decrease in column performance (that is, increasing backpressures or a drop in resolution), then steps 1 and 2 of the cleaning protocol described below should be used. Always reverse the flow during this procedure so any substances that may be trapped at the top of the column are quickly removed. During this operation do not exceed more than 50% of the recommended maximum flow rate (see Table 1). Ensure that the backpressure stays below the maximum operating pressure. 1. Wash with 2 x 1 ml injections of 2.0 M NaCl followed by 1 CV of buffer. 2. Wash with 2 x 1 ml injections of 1.0 M NaOH followed by 2 CV of buffer. If the column performance has still not returned, the additional steps below can be followed: 3. Wash with 2 x 1 ml injections of 50% acetic acid followed by 2 CV of buffer. 4. If lipid contamination is suspected, first wash with at least 1 CV of deionized water. Then wash with 1 CV of 70% ethanol followed by 2 CV of water. The flow rate may need to be slowed significantly during the 70% ethanol wash. Before use, re-equilibrate with at least 2 CV of equilibration buffer. 3.4 Frit Replacement The top frit may need to be replaced after extensive column use or if increasing backpressures are noticed. Always try to clean the column in the reverse direction (as described in section 3.3) before replacing the frit. A frit kit containing a frit removal tool, 2 O-rings, and 2 frits is available. Figure 2 shows a column diagram to assist in the replacement of the top frit. ENrich SEC Instruction Manual 7

Adjusting nut Lock nut Upper retainer Lower retainer Adaptor Fig. 2. Column diagram. 1. Start a slow flow rate of buffer (0.5 ml/min or less) through the column. 2. Remove the lower end tubing and fitting from the column. Firmly hold the bottom of the column over a sink or container. 3. Loosen the lock nut by turning it clockwise. 4. Raise the adaptor a few millimeters by slowly by turning the adjusting nut counterclockwise. 5. Unscrew the upper retainer. Let it rest on the bottom retainer. 6. Slowly pull out the upper adaptor from the glass column. Allow the buffer flow to maintain the integrity of the top of the bed. 7. Stop the pump. Plug the bottom of the column. Set the column upright in a beaker. Remove the tubing and fitting from the top of the adaptor. 8. Remove the frit from the adaptor by hooking one end of the frit removal tool/tweezer into the frit in a sideways motion with slight downward pressure. 9. Push the new frit into the end of the adaptor. 10. Replace the O-rings if they appear worn or torn. If the O-rings are replaced, wet them with buffer before the next step. 11. Add a few drops of buffer to the top of the resin bed. Insert the adaptor and push it down to the bed. Some buffer should flow out the top of the column. 12. Screw on the upper retainer. 13. Lower the adaptor to the top of the bed by turning the adjusting nut clockwise. 14. Tighten the lock nut by turning it counterclockwise. 8 ENrich SEC Instruction Manual

3.5 Storage Conditions To prevent bacterial growth in the column, it must be stored correctly. For short-term storage (up to 2 days), store it in freshly prepared buffer. For long-term storage, first wash the column with 30 ml of deionized water and then with a storage solution of 20% ethanol. Use a flow rate of 0.5 ml/min or less. Ensure that the backpressure stays below the maximum operating pressure. Always store the column with plugs at each end. Store the column in a safe place at room temperature or 4 C. Never allow the column to freeze. If, during storage or shipment the column might be exposed to temperatures above 35 C, briefly (3 min under vacuum) degas the 20% ethanol storage solution before use. ENrich SEC Instruction Manual 9

Section 4: Ordering Information Catalog # Description 780-1070 ENrich SEC 70 10 x 300 Column, 10 x 300 mm 780-1650 ENrich SEC 650 10 x 300 Column, 10 x 300 mm 780-0093 ENrich 10 Frit Kit, includes 2 frits, 1 frit remover, 2 O-rings 151-1901 Gel Filtration Standard, 6 vials 10 ENrich SEC Instruction Manual

Bio-Rad Laboratories, Inc. Life Science Group 10027325 Rev A US/EG Web site www.bio-rad.com USA 800 424 6723 Australia 61 2 9914 2800 Austria 01 877 89 01 Belgium 09 385 55 11 Brazil 55 11 5044 5699 Canada 905 364 3435 China 86 21 6169 8500 Czech Republic 420 241 430 532 Denmark 44 52 10 00 Finland 09 804 22 00 France 01 47 95 69 65 Germany 089 31 884 0 Greece 30 210 9532 220 Hong Kong 852 2789 3300 Hungary 36 1 459 6100 India 91 124 4029300 Israel 03 963 6050 Italy 39 02 216091 Japan 03 6361 7000 Korea 82 2 3473 4460 Mexico 52 555 488 7670 The Netherlands 0318 540666 New Zealand 64 9 415 2280 Norway 23 38 41 30 Poland 48 22 331 99 99 Portugal 351 21 472 7700 Russia 7 495 721 14 04 Singapore 65 6415 3188 South Africa 27 861 246 723 Spain 34 91 590 5200 Sweden 08 555 12700 Switzerland 026 674 55 05 Taiwan 886 2 2578 7189 Thailand 800 88 22 88 United Kingdom 020 8328 2000 Sig 1212