PART 11: START-UP PROCEDURES FOR THE INSTALLER



Similar documents
PART 8: FIELD WIRING. n WARNING NOTICE. Boiler Manual

prestige Condensing Water Boiler SERVICE TECHNICIAN S TROUBLE SHOOTING GUIDE TSG-PRESTIGE Date revised: 12/6/10

Luna 3 Comfort Troubleshooting Guide June 2008

Sensi TM. Wi-Fi Programmable Thermostat MANUAL OPERATION. Version: March Emerson Electric Co. All rights reserved.

Contents. Introduction

G234X-55 Conventional Gas Boiler

LMS The modular management system for condensing boilers. Control Products & Systems OEM. Answers for infrastructure.

Service Manual Models: 502, 752, 1002, 1302,

/2010 US/CA

ecomax Instructions for use Wall hung room sealed fan assisted condensing boilers For the user

Continuous flow direct water heating for potable hot water

Fossil fuel heating equipment

O. Gas boiler. Gaz 6000 W WBN H-E-N/L-S2400. Operating instructions for the end customer (2014/07) en

Corsair Link v2.4 Manual. Initial Set-up. Placing devices within the chassis

User's Instructions. Alpha HE CB25/33 and HE SY25

Quinta Range. Condensing Boilers REMEHA QUINTA RANGE. High efficiency wall hung condensing boiler with ultra low NOx emission

For installation guide see reverse of book

Continuous Monitoring of Flue and Combustible or Hazardous Gases and Vapors

OilonChooser Operating Instructions

Workshop 7 PC Software - Tracker

Servicing instructions

The NEW Greenstar i. intuitive. innovative. improved performance. installation ease

Accenta/Optima. User Guide. Servicing Organisation (Installer) name: Telephone Number: Date of Installation: Account Number: Honeywell Security

Technical Manual. FAN COIL CONTROLLER COOLING or HEATING ANALOG or PWM Art A

USERS GUIDE. LOGIC Combi 24, 30, 35. For installation guide see reverse of book

TB-A A. O. SMITH - FVIR INTELLI-VENT TROUBLESHOOTING CHART # LED STATUS PROBLEM SOLUTION

TANKLESS WATER HEATER INSTALLATION DIAGRAMS

Automation System TROVIS 5100 Ventilation Controller TROVIS 5177

1/11 CO2 DOSAGE SYSTEMS. CO2 dosage system consists of following parts;

Versatility ::::::::::::::::::::::::::::::::::::::: the best. mod/con Performance. and UP TO.

Operation manual. Daikin Altherma hybrid heat pump EHYHBH05AA EHYHBH08AA EHYHBX08AA. Operation manual Daikin Altherma hybrid heat pump.

LG Air Conditioning Multi F(DX) Fault Codes Sheet. Multi Split Units

Link 2 Vehicle Maintenance System

Condensing Boiler Efficiency

1 General information

Up To 99% Thermal Efficiency HIGH EFFICIENCY COMMERCIAL BOILERS WITH MODBUS PROTOCOL, CASCADING SEQUENCER AND FRONT-END LOADING CAPABILITY

USER MANUAL OPERATION AND USE OF CAR WITH. Diego G3 / NEVO SEQUENTIAL GAS INJECTION SYSTEM

CONTROLS KITS AND ACCESSORIES /2014 Supersedes10/2014

The Concept of Condensing Boilers

Service Manual Models:

Munchkin Heat Exchanger Maintenance

Logamax plus GB142. Applications Manual. Gas condensing boiler


USERS GUIDE. LOGIC Heat 12, 15, 18, 24, 30. For installation guide see reverse of book

RECON WATER HEATER INSTALLATION FORM

/98 USA. Service Manual. Ecomatic HS Save These Instructions!

TRANSMITTER RECEIVER THESE INSTRUCTIONS APPLY IN THE UK ONLY THESE INSTRUCTIONS ARE TO BE LEFT WITH THE USER OR AT THE APPLIANCE. Digistat Optimiser

KU DESIGN GUIDELINES APPENDIX XVI RECOMMENDED BAS I/O CONTROL POINTS BY EQUIPMENT / SYSTEM

R&D Electronics 8440 N. Waukegan Rd., Morton Grove, IL (847) Issue 12/08/06 om_207f.doc --

Operation manual. Daikin Altherma low temperature monobloc EBLQ05CAV3 EBLQ07CAV3 EDLQ05CAV3 EDLQ07CAV3

Advanced Heating & Hot Water Systems. Ultra High Efficiency Energy Star Listed Condensing Boiler

sip Sanyo Modbus Guide Technical Specification Pinouts, Cable Connections & Wiring Issue 2: February 2009 Synapsys Solutions Ltd, all rights reserved

ELECTRIC CENTRAL HEATING FLOW BOILER

Alpha Climatic Programmable Modulating Boiler Energy Manager. Installation and User Instructions

Flame Conductivity VS Flame Rectification Systems

CASCADE PROGRAMMING. Installation & Maintenance Manual v1.0

For the owner. Instructions for use. ecotec. Wall hung room sealed fan assisted condensing boilers

Model Description / Applications. Intermittent Pilot Gas Ignition Control

C. Burner management system to follow requirements of Industrial Risk Insurers (IRI).

TECHNICAL SERVICE DEPARTMENT Technical Service Bulletin Inch PowerVent LED Indicator Explanations & Troubleshooting Table

This guide will show you how to configure a Windows Mobile 6 PDA for Bluetooth connection to the KBM Systems OBDKey Bluetooth device.

Elite Monitoring System Installation and Operation

Digital timer thermosatat. isense. Installation and Service Manual AG

4-Channel Thermometer / Datalogger

Baxi Combi 80e & 105e

2 4PI175 issue 1_6/01. How to unset system in alarm. Programs 1, 2 and 3. Access codes. How to operate Personal Attack

Electric Flow Boiler

Wireless 7 Day Programmable Room Thermostat

Principals of Condensing Boiler System Design

Centauri. Condensing Fire Tube Water Boiler 399 to 1000 MBH

Technical Information

Drayton Digistat +2RF/+3RF

RESIDENTIAL HEATING OIL SERVICE CONTRACT ANNUAL COST $276.00

TABLE 1: Wiring Terminals. Connect to... 1C 1H 2C 2H 1H1C 2H1C 2H2C 3H2C

TC-9102 Series Surface Mount Temperature Controllers

GeniSys 12V. Model Description / Applications. Advanced 12 Vdc Burner Control

User s Operation Manual - contents

Service manual. ActivA

Operational Overview and Controls Guide. Two or Three Pump IronHeart Lite with Variable Frequency Drives

B/S/H/ Error codes and service programmes PH

Oil - kerosene burners

Energy Efficient Operations and Maintenance Strategies for Boilers

KRONOS GA11 WEEKLY-PROGRAMMING DIGITAL CHRONOTHERMOSTAT FOR THE REMOTE CONTROL OF HOT AIR GENERATORS THROUGH BRAHMA INTERFACE BOARD APPLICATION

Operation manual. Daikin Altherma ground source heat pump EGSQH10S18AA9W. Operation manual Daikin Altherma ground source heat pump.

OASIS SERVICE & TROUBLESHOOTING MANUAL (WITH DM10 OR DM12)

Variable Air Volume - VAV

Service Manual Models:

1 QPro HelpFile 01.EN COPYRIGHT CONTRIVE

Daikin Altherma Hybrid Heat Pump

THERMO KING TRUCK & TRAILER UNIT ALARM CODES THIS DOCUMENT SHOWS ALL CURRENT ALARM CODES FOR THERMO KING TRUCK AND TRAILER UNITS.

Communicating Controls Service Manual

User manual. Solid (FR 98,),

Baxi Combi 130 HE. User s Operating Instructions. Gas Fired Wall Mounted Condensing Combination Boiler

Alerts and Delta T Diagnostics with the Prestige 2.0 IAQ Thermostat

Boiler Preparation, Start-Up and Shutdown

Vitodens 200, B2HA / B2HB - Product Introduction

Transcription:

PART 11: START-UP PROCEDURES FOR THE INSTALLER NOTICE It is important to note that the user can adjust the heat curve down by adjusting the central heating temperature to a lower setting. 212 CENTRAL HEATING CURVE Factory Default 212 CENTRAL HEATING CURVE Plot your Curve 203 201 194 203 194 185 176 FUNCTION 9 185 176 167 167 SUPPLY OUTLET TEMPERATURE (F) 158 149 131 122 113 104 95 86 77 68 50 FUNCTION 11 FUNCTION 8 DEFAULT RESET CURVE FUNCTION 10 SUPPLY OUTLET TEMPERATURE (F) 158 149 131 122 113 104 95 86 77 68 50 41 41 32 - -41-24 0-9 9 27 45 63 81 99 32-0 -41-24 -9 9 27 45 63 81 99 5 OUTSIDE TEMPERATURE (F) 68 OUTSIDE TEMPERATURE (F) Fig. 11-1 Fig. 11-2 A. ELITE CONTROL STATUS MENU The Elite Controller also has the ability to review the status of the system. To access the Status screens simply press the right arrow key Once the first value is displayed then press the UP arrow key or Down arrow key to access additional information. At any point you may press the RESET button to exit the Status screen. Listed below are the Status screens. SUPPLY 180 F RETURN 150 F This screen is displayed after pressing the key as described above. This screen displays the actual temperature that the supply and return sensors are measuring. NOTE: If the boiler is configured to use a 0 10 volt input, the Return sensor is disabled and the second line of the display will be blank. CH SET 180 F SUPPLY 122 F This screen displays the current Central Heating temperature set point on the top line. NOTE: This temperature set point may vary from what was set in the Boiler Settings if an outdoor sensor is used. The actual temperature measured by the supply sensor is displayed on the bottom line.

DHW SET 119 F DHW 117 F BUS COMM NO CONN This screen displays the current domestic hot water temperature set point on the top line. The actual temperature measured by the domestic hot water tank sensor (HTP 7250P-325) is displayed on the bottom line. If a mechanical aquastat is used in place of the recommended sensor, the second line will display OFF in place of the temperature if the aquastat is measuring close to its set temperature or ON in place of the temperature if the aquastat temperature too low. OUTDOOR 11 F FLUE 95 F This screen displays the current outdoor temperature on the top line. If there is no outdoor sensor connected to the boiler, this line will display OFF in place of the temperature. If the outdoor sensor is shorted, this line will display ON in place of the temperature. The second line displays the current flue temperature of the boiler. FLAME FAN SPEED 0.0uA 3497 RPM This screen displays the boiler flame current on the top line. The second line displays the speed of the fan in the boiler. 0-10 V 0.0 V The top line displays the voltage on the optional input. This voltage is only relevant if an external 0 10 volt signal is being used to control the boiler. This display shows the status of the communication bus between multiple boilers. If the boiler is in a single boiler configuration, the display will show NO CONN. If the boiler is used in a multiple boiler configuration and if it is the master boiler, and other boilers are connected to the communication bus and power is on to them, then this screen will show the address of each boiler connected to the bus. POWER ON CH ON The top line of this display indicates the amount of hours the boiler has power applied to it in the life of the boiler The second line indicates how many hours the burner has been on for a central heat demand in the life of the boiler DHW ON GOOD IGNIT 1X The top line of this display indicates the amount of hours the burner has been on for a domestic hot water demand in the life of the boiler. The second line indicates how many times the burner has successfully ignited in the life of the boiler. The following 10 screens display the last ten lockout faults that the boiler had. The faults are displayed from most recent to oldest by depressing the key. FAULT HISTORY 10 07/27/2009 Mo 5:19A This screen displays the last lockout fault the boiler controller had. The top line will alternate between the words FAULT HISTORY and the actual fault encountered if one has occurred and 60

the bottom line will display the date and time that the fault occurred FAULT HISTORY 20 08/28/2009 Fr 5:19A This screen displays the second oldest lockout FAULT HISTORY 30 08/28/2009 Fr 5:19A This screen displays the third oldest lockout FAULT HISTORY 40 This screen displays the fourth oldest lockout FAULT HISTORY 50 This screen displays the fifth oldest lockout fault the boiler controller had. The top line will alternate between the words FAULT HISTORY and the actual fault encountered if one has occurred and the bottom line will display the date and time that the fault occurred FAULT HISTORY 60 This screen displays the sixth oldest lockout FAULT HISTORY 70 This screen displays the seventh oldest lockout FAULT HISTORY 80 This screen displays the eighth oldest lockout FAULT HISTORY 90 This screen displays the ninth oldest lockout 61

FAULT HISTORY 08 28 2009 10:01A This screen displays the tenth oldest lockout B. ELITE HEATING BOILER TEST MODE This Function is intended to simplify the gas adjustment if needed. Listed in Figure 11-3 are the recommended combustion settings for the gas type selected to run the Elite Boilers. Automatic Modulation does not take place when the controller is in Test Mode. The boilers will modulate down if the program set point is approached while running in test mode. It is recommended you open as many heating zones as possible to create a heat demand so the test mode operation will not be interrupted. To exit the test mode, Press the Up and Down arrow keys simultaneously. NOTE: The boiler will automatically exit the service mode after 20 minutes of operation. C. CASCADE MENU This menu is accessed by pressing the key from the default menu or the key from the status menu. CASCADE MASTER READY This screen is an informative screen to tell the user that the boiler is configured as a cascade master boiler and that the cascade system is ready to accept a demand for heat. The second line indicates the status of the system pump output of the cascade system. This screen will alternate with the default screen every 5 seconds or it can be accessed by pressing the key from the default screen. CASCADE NO FOLLOWER Description: This screen will be displayed when the boiler is configured as a master boiler and there are no follower boilers connected to the master or none of the follower boilers are powered up. The second line indicates the status of the system pump output of the cascade system. This screen will alternate with the default screen every 5 seconds or it can be accessed by pressing the key from the default screen. CASCADE NO SENSOR Description: This screen will be displayed when the boiler is configured as a master boiler but there is no system temperature sensor connected or the system sensor is defective. The cascade system will still function in this situation but will function with reduced efficiency and all boilers will run simultaneously rather than in a staged fashion. The second line indicates the status of the system pump output of the cascade system. This screen will alternate with the default screen every 5 seconds or it can be accessed by pressing the key from the default screen. CASCADE TT 0123 567 SYS PUMP ON 12:47P Description: This screen shows information about the cascade status. The TT in the center of the top line shows that the cascade demand is coming from the TT contact being closed. You may also see DHW if the demand is from a DHW sensor or 0-10 if the demand is from the 0-10 volt input. The next numbers show which boiler addresses are currently communicating to the master. If a boiler address is not used or not communicating, the number will not show on the display. In the example above, boiler address #4 is not communicating. When a boiler in the system is firing, its address number will alternate with a. to signify it is firing. The bottom line shows the status of the system pump output contacts. CASCADE PWR 100% PRESENT 01234567 62

PART 11: START-UP PROCEDURES FOR THE INSTALLER (CONTINUED) Description : This screen shows the overall cascade power output. The range of this value is the number of boilers communicating with the master x 100 so in the example above, the maximum cascade power is 800%. The second line shows which boiler addresses are communicating with the master boiler. CASCADE SYST 118 F CASCADE SET 190 F Description: This screen shows the current system temperature sensor reading on the top line and the cascade system temperature setting on the bottom line. BOILER 0 100 % BOILER 1 56 % basis for boilers addressed as 0 and 1. In the above screen, boiler 0 is at 100% firing rate and boiler 1 is at 56% firing rate. If this were a 2 boiler system, the CASCADE PWR screen above would now be at 156% BOILER 2 0 % BOILER 3 0 % addressed as 2 and 3 BOILER 4 0 % BOILER 5 0 % addressed as 4 and 5 BOILER 6 0 % BOILER 7 0 % addressed as 6 and 7. D. TEST MODE ACCESS Carbon Monoxide (CO %) Carbon Dioxide (CO 2 %) Fig. 11-3 COMBUSTION SETTINGS ON ALL MODELS Natural Gas Propane LP low high low high 0 20 ppm 70 ppm 135 ppm 0 20 ppm 80 ppm 150 ppm 8½% 9½% 8½% 9½% 9½% 10½% 9½% 10½% To Activate the test mode Press the up arrow and ENTER key together for 1 second. The boiler will go through the ignition sequence then the user will adjust the Fan Speed by pressing the up arrow key to increase the fan speed or the down arrow key to decrease the fan speed. SERVICE RUN 3400 RPM PUMP ON 4:49P 63