Vacuum drying oven for non-flammable solvents



Similar documents
VDL 53 - Vacuum drying oven for flammable solvents

Material test chamber with mechanical convection

40 Vacuum drying ovens

Heating oven with mechanical control

Incubator with mechanical convection

Heating oven with mechanical convection

Climate chamber with illumination

VACUUM HEATING AND DRYING OVENS Gentle and safe

Thermo Scientific Heratherm Microbiological Incubators. Safe, easy and efficient

Thermo Scientific Heratherm Microbiological Incubators. Safe,

Thermo Scientific Heraeus Heating and Drying Ovens. Quality that meets every laboratory need

Visions become real. Temperature control and cooling systems. The innovative and reliable solution

Refrigerators - Freezers. Ekofrigolab & Ekobasic Series

STD - STANDARD VERSION extended possibilities reasonable price wide range of optional equipment

DMP 331. Industrial Pressure Transmitter for Low Pressure. Stainless Steel Sensor

Product-friendly and fast...

TECHNICAL DATA E-PRO COLD UNITS Refrigerated glass display units, CDDL, CDD and CDDH series

Freezers - Ultrafreezers. Platilab & Irilab Series

German engineering under high pressure

EVAC ONLINEVAC TECHNICAL DATA EVAC ONLINEVAC 16, 24 V DC. Required maintenance space 700 mm. Required maintenance space 200 mm 360 Ø13

VTS³ and VCS³ Stress Screening Systems. More Power for Maximum Quality Assurance

Clinic Washer-Disinfectors. Washer-Disinfector Line

HERZ-Thermal Actuators

Hydraulic Control Solutions

Eurovacuum EV Series. Single Stage Oil Sealed Rotary Vane Pump

HIGH PRESSURE TECHNOLOGY HYDRAULICS PNEUMATICS TESTING EQUIPMENT

Trocknungs_Prozess_engl_04_ :14 Uhr Seite 1 YOUR COMPETENT PARTNER. Drying- and Processing Technology

Spetec. Laminar Flow Box. Portable Clean Room Technology

DIESEL-FUELED, BLOWN AIR, DUCTABLE HEATERS

Convection Ovens. BX Classic. Models BX4 / FG 189C, BX / FG 158C, BX10 / FG 180C. Operator's Manual

Blood Bank Refrigerators according to DIN Blood Plasma Freezers according to DIN 58375

WATERBATHS AND OILBATHS

VACUUM HEATING AND DRYING OVENS Gentle and safe

Diagram of components 2. Reducer..3

Digital pressure gauge for industrial applications Model DG-10-S, Standard version Model DG-10-E, Enhanced version

STERILIZERS, LABORATORY DRYING OVENS

Incubators, cooled incubators, drying ovens, sterilizers, climatic chambers

Weiss Mobile Air Conditioning Systems

EuroFID Total Hydrocarbon Analyzer. Precise Determination of Total Hydrocarbons in Air for Corrosive as well as Condensing Gases

ElastoFlake & ElastoTec

CoolTop. A unique water cooled air-conditioning unit for server room cooling from the top AC-TOPx-CW-240/60

CRAC Precision climate control units for data centres

Turbine Flow Sensor Series VTR

Specials. designed. 3rd edition 2015 English. for scientists 1

Integrated pressure measurement

Order Code for GEA Tuchenhagen VESTA Sterile Valves. Type H_A 2/2 Way Seat Valve

3/2-way Solenoid Valve, direct-acting, NC or NO

Self-operated Temperature Regulators Temperature Regulator Type 1u

4 Posiflow Proportional Solenoid Valves

OEM Pressure Transmitters for heavy-duty applications, Type MBS 1200 and MBS 1250

How To Control A Power Supply With A Mini Transmitter And Switch (Power Supply)

Power consumption (kw)

Shaking Water Baths THERMOLAB


Fast closing valve Series 75

Fully Automated Distillation of Petroleum Products including Biofuels OptiDist - the Optimal Solution

MCP 100 MCP 150. Modular Compact Polarimeters. ::: Superior Optical Instruments

SOHOline and SOHO Slimline The SOHOline and SOHO Slimline offer a modular, sturdy and compact design

Plastic tube flowmeters Series PT/PS

THE OPTIMAL SOLUTION FOR SMALL AND MEDIUM DATA CENTER

Knürr Smaract. Knürr Smaract. CompactRack

Electronic Pressure Switch EDS 300

Direct steam injection humidifiers

Climate Test Chamber. System Weiss. Type WK3-2000/40

DIESEL-FUELED, BLOWN AIR, DUCTABLE HEATERS

BENCH TECH 150. IVD In vitro diagnostic-medical device. General information Type of instrument: Bench chemical hood. Technical datasheet BenchTech150

Portable digital microprocessor thermometers with interchangeable probes

Differential Pressure Sensors for air and non-corrosive gases, with calibration certificate

Fluid Level Gauge Fluid Level Sensor Temperature Switch FSA / FSK / TS

Hand-held thermometer Model CTH7000

FVA THIRD-GENERATION VERTICAL SATURATED-STEAM STERILIZERS

LABORATORY / MEDICINE / PHARMACEUTICAL REFRIGERATORS

ATL Fuel Level Sender Probes

6 Crankcase Ventilation

OT 40L / 90L. Laboratory Steam Sterilizers

Refrigeration Compressed Air Dryer Buran Ultrapulse

Electric Rotary Actuator - On/Off or programmable control actuator

VACUUM HEATING AND DRYING OVENS Gentle, intelligent and safe

High-efficient gas boiler CompactGas


COMBIMASS. Technical Data COMBIMASS eco-bio +

Series description: Wilo-Yonos MAXO

Series description: Wilo-Drain TC 40

helosauna.com STEAM BATH PRODUCTS

Microwave Meter. Instruction Manual

BR I Blood Bank Refrigerators

Probably the best Speed Vacuum Concentrators in the world

HEAT MONITORING AND CONTROL INSTRUMENTS FOR TRANSFORMERS MB 103 TEMPERATURE CONTROL UNIT PT 100 TEMPERATURE SENSOR

DIGITUS Network & Server Cabinets. UNIQUE Series

How To Make A Fronius Cl Power Inverter

High pressure reactors Where are your limits?

Assisted lift operated 2/2-way solenoid valves Type EV250B

SALES SPECIFICATION. SC7640 Auto/Manual High Resolution Sputter Coater

VdS en. VdS Guidelines for water extinguishing systems. Non-return valves. Requirements and test methods. VdS en : (01)

T 300 Tray sealer. Automatic tray packaging in the smallest of spaces

Reference V, 50 Hz A V,60 Hz V, 50/60 Hz A V, 50/60 Hz V, 50 Hz A V, 60 Hz

Rittal TopTherm fan-and-filter unit

Component Series Racks Component Series Rack Plus Bundles...3 Component Series stackable skeleton Racks...4

Photovoltaic Solar Energy Unit EESFB

Actuators and Sensors. Products

Transcription:

VD series 53 Vacuum drying ovens Vacuum drying oven for non-flammable solvents A BINDER vacuum drying oven of the VD series is impressive while gently drying with its homogeneous temperature distribution. The patented expansion shelf technology from BINDER ensures optimal heat transfer. The shelves are easy to position where required and the inner chamber of the vacuum drying oven is easy to clean. Advantages: Maximum occupational safety with one-of-a-kind safety concept Fast, condensation-free drying processes Homogeneous specimen drying Areas of application: Electronics / Semiconductor Industry Plastics Industry Pharmaceuticals Industry

Customer benefits Features Customer benefits Characteristics APT.line Drying Safety concept Cleaning Complete system Accessories and Services Gentle drying throughout the chamber interior Absolute temperature uniformity Direct transfer of heat to the specimens Reproducible drying results Fast drying thanks to accelerated drying process Light specimens (e.g. powder) are not swirled Maximum occupational safety with recognized safety concept Protection for user and laboratory Simple, time-saving cleaning Durable materials Everything from one source ptimal working height 50% less noise Pressure and temperature profiles are depicted simultaneously Convenient documentation and validation BINDER INDIVIDUAL for customer-specific solutions Worldwide BINDER Service APT.line preheating chamber technology Thermal conducting plates for homogeneous temperature distribution Condensation-free inner chamber Patented, flexible positioning of the expansion racks with large contact surfaces BINDER Cross-Flow Principle Even flow throughout the inner chamber from bottom to top Finely adjustable valve without turbulence, individually controlled Tested security Spring-mounted safety glass panel with shatter protection (FDA tested) Standard interior flushing with inert gas Electronic components are decoupled from the inner chamber Smooth inner chamber with rounded corners Fixtures are fully removable Inner chamber made of highly corrosion resistant stainless steel V4A (1.4571) Coordinated, modular system Contains vacuum drying chamber, vacuum pumps, module and connection kit for various sizes Application-specific vacuum pumps (standard membrane pump, speed-controlled membrane pump) Comprehensive product portfolio Years of proven and recognized validation and documentation materials Various options: Digital pressure indicator, object temperature indicator Vacuum pump and chamber controllable using FDA-compliant software APT-CM Worldwide service network BINDER GmbH P Box 102 D-78502 Tuttlingen Address: Im Mittleren Ösch 5 D-78532 Tuttlingen, Germany

Performance characteristics Electronically controlled APT.line preheating chamber with 2 expansion racks assuring temperature accuracy and reproducible results Temperature range from 15 C above ambient temperature to 200 C MP controller with 2 programs with 10 sections each or switchable to 1 program with 20 sections Integrated weekly program timer with real-time function Digital temperature setting with an accuracy of one degree Elapsed time indicator Precision-adjustable ventilation valve Precision-adjustable inert gas valve with Cross-Flow-Technology All electrical components are decoupled from the inner chamber Spring-mounted safety glass panel with shatter protection Independent adjustable temperature safety device class 2 (DIN 12880), with visual temperature alarm Measuring port DN 16 in rear panel Analog pressure gauge (displays pressure difference between the inner chamber and ambient pressure) Electro polished inner chamber, suction and ventilation tubes, pressure container, expansion racks, and ball valve are made of stainless steel Door gasket made of tempered silicone 2 x 24 V DC (max 0.4 A) switching outputs, switched via 2 control contacts in the program editor RS 422 interface for communication software APT-CM DataControlSystem 2 patented, flexible aluminum expansion racks Also available as complete system with module and vacuum pump. Features: Reduced noise level Practical working height Coordinated system BINDER test confirmation BINDER GmbH P Box 102 D-78502 Tuttlingen Address: Im Mittleren Ösch 5 D-78532 Tuttlingen, Germany

Specifications VD 53 Exterior dimensions Width (mm) 635 Height (incl. feet) (mm) 775 Height with optional vacuum module (mm) 625 Height with optional vacuum module (mm) 1400 Depth (mm) 550 Plus door handle, connection (mm) 100 Wall clearance, rear (mm) 100 Wall clearance, side (mm) 135 Interior dimensions Width (mm) 400 Height (mm) 400 Depth (mm) 330 Interior volume (l) 53 Expansion racks (aluminum) (number standard/max.) 2 / 5 Distance between the racks (mm) 62 Usable space per rack (width x depth) (mm) 349 x 320 Load per shelf (kg) 20 Permitted total load (kg) 45 Weight (empty) (kg) 95 Temperature range Temperature range approx. 15 C above ambient temperature to ( C) 200 Temperature variation 1) 100 C (± K) 2 200 C (± K) 4,5 Temperature fluctuation (± K) 1) 0,1 Warm-up time 1), 2) to 100 C (min.) 80 to 200 C (min.) 115 Vacuum connection with small flange (DN mm) 16 Measuring access port with small flange (DN mm) 16 Inert gas connection with flow limiter thread (RP) 3 / 8 BINDER GmbH P Box 102 D-78502 Tuttlingen Address: Im Mittleren Ösch 5 D-78532 Tuttlingen, Germany

Specifications Permitted end vacuum (mbar) 0,01 Leak rate (max. bar 1/h) 0,01 BINDER GmbH P Box 102 D-78502 Tuttlingen Address: Im Mittleren Ösch 5 D-78532 Tuttlingen, Germany

Specifications VD 53 Electrical data IP protection class acc. to EN 60529 IP 20 Voltage (± 10%) 50 / 60 Hz 230 Nominal power (kw) 1,2 Energy consumption at 100 C (W) 150 at 200 C (W) 445 1) Value with aluminum racks 2) To 98% of the set value All technical data are specified for units with standard equipment at an ambient temperature of 25 C and a line voltage fluctuation of ±10%. These average values have been determined according to the BINDER factory standard, respecting the recommended wall clearances of 10% of the height, width and depth of the inner chamber. Differing ambient temperatures and production-related device-specific variances can lead to varying technical data. Therefore, we recommend individual customer-specific calibration or validation for applications on the limit of the permitted ambient temperature range. BINDER GmbH P Box 102 D-78502 Tuttlingen Address: Im Mittleren Ösch 5 D-78532 Tuttlingen, Germany

ptions Measuring port Vacuum-tight access port into the device for measuring lines (9-pin). Specimen temperature display Uses PT 100 sensor and digital temperature display. Calibration certificate Measurement in center at predefined test value. Expandable with additional measuring points or test values based on your requirements. BINDER GmbH P Box 102 D-78502 Tuttlingen Address: Im Mittleren Ösch 5 D-78532 Tuttlingen, Germany

ptions VD 53 Connection kit consists of: clamping ring, aluminum centering ring, small flange with hose nozzle, 2.5 m rubber hose, and 2 hose clamps Measuring port for vacuum-tight access port of measuring lines into the device (9-pin) Factory calibration certificate, measurement in center of chamber at 100 C or at specified testing temperature Extension to factory calibration certificate. Each additional measurement at additional measuring point or testing temperature Factory calibration certificate for digital pressure gauge. Measurement at 100 mbar or at specified test pressure (range 20-900 mbar) Extension to factory calibration certificate for digital pressure gauge. Each additional measurement with additional test pressure (range 20-900 mbar) Temperature measurement of the specimen with flexible PT 100 sensor and digital specimen temperature display Factory calibration certificate for digital specimen temperature display. Measurement at 100 C or at specified testing temperature VP 1.1 chemical membrane pump (nominal air flow 2.0 m³/hour, final pressure 7 mbar), with separator and emission condenser (230 V 1N ~ 50 / 60 Hz) VP 2.1 chemical membrane pump (nominal air flow 3.4 m³/hour, final pressure 7 mbar), with separator and emission condenser (230 V 1N ~ 50 / 60 Hz) VP 3.1 speed-controlled chemical membrane pump (nominal air flow 4.6 m³/hour, final pressure 1.5 mbar), with separator and emission condenser (230 V 1N ~ 50 / 60 Hz) Expansion racks, aluminum Expansion racks, stainless steel Exchange and calibration to stainless steel expansion racks, standard equipment aluminum expansion racks are replaced Door gasket, FKM (Viton) Digital pressure display, measuring range from 1 mbar to atm. pressure, display accuracy 1 mbar Vacuum module for installation of vacuum pumps, with switchable power socket (N/FF) (230 V / 16 A) Vacuum module with chemical membrane pump VP 1.1 (nominal air flow 2.0 m³/hour, final pressure 7 mbar), with separator and emission condenser, including all necessary vacuum connection parts 230 V 1N ~ 50 / 60 Hz Vacuum module with chemical membrane pump VP 2.1 (nominal air flow 3.4 m³/hour, final pressure 7 mbar), with separator and emission condenser, including all necessary vacuum connection parts 230 V 1N ~ 50 / 60 Hz Vacuum module with speed-controlled chemical membrane pump VP 3.1 (nominal air flow 4.6 m³/hour, final pressure 1.5 mbar), with separator and emission condenser, including all necessary vacuum connection parts, as well as digital vacuum controller (measuring precision 1 mbar) 230 V 1N ~ 50 / 60 Hz BINDER GmbH P Box 102 D-78502 Tuttlingen Address: Im Mittleren Ösch 5 D-78532 Tuttlingen, Germany