80PK-27 SureGrip TM Industrial Surface Temperature Probe



Similar documents
K Standard Grade Ni-Cr vs Ni-Al (Chromel vs Alumel)

The table below lists the symbols used on the Clamp and/or in this manual. Important Information. See manual.

Temperature Humidity Meter

How To Use The Visifault Visual Fault Locator

i410/i1010 AC/DC Current Clamp

MicroScanner 2. Cable Verifier. Getting Started Guide

HVAC Clamp Meter. Users Manual

62 Max/62 Max + Infrared Thermometer

CO-220 Carbon Monoxide Meter

EPM3. Phase Sequence and Motor Rotation Tester. Users Manual

Troubleshooting Guide, Freedom and Fleet Power Inverter/Chargers

T+ and T+ PRO Electrical Tester

Automatic taper of charge rate for superior battery life through good equalization of cells and low water use rate.

1587/1577. Insulation Multimeters. Technical Data. Two powerful tools in one.

323/324/325. Calibration Manual. Clamp Meter

MICROMAPPER. Users Manual. LAN Wiremap Checker


Multimeter with Temperature

Installation and Operation Manual. Digital Remote Meter for Monitoring System Performance. Version: RM-1

Laptop Power Adapter for home/office User Manual

CM100. Carbon Monoxide Meter. Users Manual Mode d emploi Bedienungshandbuch Manual d Uso Manual de uso Användarhandbok

5616 Platinum Resistance Thermometer User s Guide

10 Multimeter. Users Manual

Multifunction Process Calibrator

Say Hello to Your Precision Cooker

Operating Manual UWAPS-TINY Series

REDI-LINE ELECTRIC GENERATORS USER'S GUIDE. Rugged, Reliable, DC to AC Power Conversion

Using Thermocouple Sensors Connecting Grounded and Floating Thermocouples

FLEX by 3M Light Module System

Wireless Indoor/ Outdoor Thermometer

A99B Series Temperature Sensors

Model UT713 OPERATING MANUAL

MGO Insulated Thermocouples Index

New thermometers and accessories to grow your business

RGC-IR Remote Gas Calibrator for IR400

Instructions & Safety Information Models A220-20D and A220-20L Version 2

How To Use A Cdm250 Digital Multimeter

Toroidal Conductivity Sensor

Loop Calibration and Maintenance

Threaded Inline Air Heaters

16-Port Gigabit Green Switch (TEG-S16Dg) 24-Port Gigabit Green Switch (TEG-S24Dg)

Leak Detection System

Manual. Solar Fountain Mobile Phone Charger

DUAL%CHANNEL BROADBAND%LINEAR%AMPLIFIER Model&A800D

Universal Laptop Charger

user s manual Battery Case model #: SPB3200 Battery Case Charger for Samsung Galaxy S 4

Advantium 2 Plus Alarm

DUSTTRAK AEROSOL MONITOR SOLAR POWER KIT MODEL

1N59xxBRNG Series. 3 W DO-41 Surmetic 30 Zener Voltage Regulators

Smile 11 AS-i Emergency stop with safe AS-i input node

Model 77 Series IV Digital Multimeter

Fossil fuel heating equipment

OPERATING MANUAL CONTRACTOR STYLE AXIAL FANS

Model HPX10 Series Automatic Battery Charger User s Manual Rev. 1.0 October 17, 2006

Infrared Thermometer Calibration A Complete Guide

3EZ6.2D5 Series. 3 Watt DO-41 Surmetic 30 Zener Voltage Regulators

Product Data Sheet 3M Mini-Clamp II Plug and Socket Wiremount Connectors

Seven function digital multimeter

ATS Overhead Table Shelf System INSTRUCTION MANUAL

Tina 2A/B Adaptor unit

BUB-110B. Portable Power Pack. Compact USB Battery Charger for up to 5 Smartphones and Mobile Devices. User Manual

Periodic Verification System Model 775PVS

Manual Ranging MultiMeter

525B. Temperature/Pressure Calibrator. Getting Started Guide

KVM - DVI, USB 2.0, Cat 5 Extender

HIH-4000 Series Humidity Sensors

6 & 12 Volt Battery and Systems Tester with 100 Amp Load

, User s Manual

Online data sheet PET-1CB010N10SVMC PET PRESSURE SENSORS

Dual Laser InfraRed (IR) Thermometer

Reliance DuraStar ORDINARY LOCATION INSTALLATION, OPERATING & MAINTENANCE INSTRUCTIONS

Infrarot-Bewegungsmelder IP44

ABB Drives. User s Manual. Pulse Encoder Interface Module RTAC-01

Installation and Operating Instructions (for chargers shown below)

±15 V Current-Limited Power Supply

RI-215A Operator s Manual. Part Number: RK Revision 0 Released: 10/3/05

SOLAR ELECTRIC MODULE ES-124 & ES-62T Owners Manual and Installation Guide

Nest Learning Thermostat Installation Guide. Installation step-by-step

Users Manual. Temperature Calibrator

16/32 Channel 1U Rack Mount CCTV Power Supply

AutoRanging Digital MultiMeter

DTM04 TANK MONITOR DTM08 TANK MONITOR Dtm12 TANK MONITOR. Installation and Operation Manual


Thick Film Resistor Networks, Dual-In-Line, Molded DIP

Original instructions Tina 3A/Aps Adaptor unit

READ FIRST! Universal Car/Air Adapter User Manual

Mini Power Bank and Charger

ENGLISH FRANÇAIS DEUTSCH ESPAÑOL ÐÓÑÑÊÈÉ

Duct Temperature Sensors

Models CT-001, CT-002 Owner s Manual

Mold Alert... Operation Manual P0270

Air Sensor. SAC Ex. Manual ATEX. AQ Elteknik AB

ALL WEATHER W-SERIES QUARTZ TUBE ELECTRIC INFRARED RADIANT HEATER INSTALLATION USE & CARE MANUAL

Single Station Remote Alarm

Mini-HDMI Series MINIATURE MULTIMODE FIBER OPTIC HDMI TRANSMISSION SYSTEM

V-2901 UNIVERSAL DOOR ANSWERING SYSTEM

3M High Flex Life Cable.050" 28 AWG Stranded, PVC 3319 Series

AXIS T81B22 DC 30W Midspan

Amps Per Bank. Total Output. Battery System. Model Name. 6 amps 12 amps 10 amps 20 amps 30 amps 40 amps 15 amps 30 amps 45 amps

User Manual (English)

Transcription:

80PK-27 SureGrip TM Industrial Surface Temperature Probe XWWarning Instruction Sheet To avoid electrical shock, do not use this probe when voltages exceeding 24 V ac rms or 60 V dc are present. The probe tip is electronically connected to the output terminals. XW Attention Pour éviter les risques d électrocution, ne pas utiliser cette sonde quand la tension est sepérieure à 24 V efficaces en courant alternatif ou 60 V en courant continu. La pointe de la sonde est reliée électriquement aux bornes de sorties. XW Warnung Um Elektroschock zu vermeiden, dürfen Sie den Meßstift nicht in der Anwesenheit von Spannungen über 24V Wechselstrom oder 60V Gleichstrom verwenden. Die Spitze des Meßstifts ist mit den Ausgangsanschlüssen elektrisch verbunden. XW Advertencia Para evitar descargas eléctricas, no use esta sonda cuando se apliquen voltajes que sobrepasen 24 V ca rcm o 60 V cc. La punta de la sonda está conectada eléctricamente a las terminales de salida. Introduction The 80PK-27 SureGrip TM Industrial Surface Temperature Probe is designed for reliably measuring temperatures to 600 C (1112 F) on flat or slightly convex surfaces, while retaining a long service life. Specifications Type: K (Chromel vs Alumel) Measurement Range: -127 C to 600 C (-196.6 F to 1112 F) Junction Accuracy: -127 C to 0 C ±4.4 C (-196.6 F to 32 F ± 7.92 F) 0 C to 183 C ±2.2 C (32 F to 361 F ±4.86 F) 183 C to 600 C ±1.2 % of reading in C (361 F to 1112 F ± <1.2 % of reading in F) Output: 25 C (77 F) = 1.00 mv (Reference junction at 0 C) Seebeck Coefficient: 25 C (77 F) = 40.50 µv/ C November 2004 2004 Fluke Corporation. All Rights Reserved. All product names are trademarks of their respective companies

Measurement Time (Time Constant): 1 time constant equals 330 ms; 5 time constants equal final reading. See Application Information below. Maximum Voltage Rating at Probe Tip: 24 V ac rms, or 60 V dc Probe Tip: Maximum Temperature: 600 C (1112 F) Material: 303 stainless steel Sheath Material: 303 stainless steel Cable Length: 40 inches (1 meter) Cable Isulation: Material: PVC Maximum Temperature: 105 C (220 F) Minimum Temperature: -20 F Conductors: Type: K Size: AWG #24 stranded (7 strands of #32) Length: 1.2 meters nominal (4 ft) Handle: Material: Hytrel Maximum Temperature: 65.6 C (150 F) Minimum Temperature: -40 C (-40 F) Connector: Type: yellow mini-thermocouple connector with 0.792 mm (0.312 in) pin spacing Material: Hytrel Maximum Temperature: 125 C (275 F) Dimensions: Diameter: 22.9 mm (0.9 in) Length: 322.6 mm (12.75 in) Measurement Considerations Instrument Compatibility The 80PK-27 is designed to be compatible with any temperature measuring instrument that accepts Type K thermocouples, has a miniature thermocouple connector, and has cold reference junction compensation. Accuracy of the temperature measuring instrument must be considered along with the 80PK-27 accuracy specifications in order to determine the overall accuracy of the combination. Temperature Limitations The probe tip has continuous temperature rating of 600 C. However the rest of the assembly is rated for a lower temperature. See the specifications for further information. Media Limitations Media must be compatible with Chromel, Alumel, and 303 stainless steel. Application Information At high temperatures, a surface temperature probe removes a small amount of heat from the measured surface. At 600 C on a polished metal surface, the temperature at a contact point will be lowered, typically not more than 2 C. A lowering of the temperature at the contact point is less likely (and contact response time is quicker) on clean, polished, thermally conductive surfaces than on materials with low thermal conductivity, such as plastic or rough, contaminated surfaces. To obtain the best thermal contact and performance, the stainless steel ring must make full and firm contact with the measurement surface.

Operation Use the 80PK-27 as follows: 1. Using the miniature thermocouple connector, connect the 80PK-27 to a compatible Type K temperature measuring instrument. 2. Turn on the measuring instrument and select the appropriate range and scale. 3. Read the temperature on the measuring instrument. When no heat or cold is applied to the sensing ribbon, the measuring instrument should display the ambient (room) temperature. If the instrument does not readout properly, refer to Troubleshooting. Measuring Technique To improve the accuracy of your temperature measurements: When measuring higher than ambient temperatures, adjust the connection between the probe and the surface until you get the highest temperature reading. When measuring lower than ambient temperatures, adjust the connection between the probe and the surface until you get the lowest temperature reading. When measuring near ambient temperatures, make the reading when the thermometer readout is most stable. Troubleshooting When no heat or cold applied to the probe, the measuring instrument should display the ambient temperature. If the measuring instrument does not do so, try the following: 1. Verify that the temperature measuring instrument is designed for Type K thermocouples. It should have a yellow input connector and/or be marked K. 2. Check for an open circuit indicator on the measuring instrument. Some temperature measuring instruments have a built-in circuit to indicate if the connected probe is open. (All Fluke instruments have this feature.) Refer to instrument's owner s manual to see if this feature is available. If you suspect a broken connection, use an ohmmeter to check probe continuity from pin to pin. If the ohmmeter should read 10 ohms or less if there is continuity. 3. Short the two input pins of the measuring instrument with a piece of wire. If the instrument is functioning it should indicate the ambient temperature.

8" (203.2 mm) Diameter:.305" (7.747 mm) Tip Diameter:.585" (14.859 mm) Figure 1. 80PK-27 baf01f.eps Cleaning Dip ¼ of the probe tip in the water. Do not dip the entire probe tip! Brush lightly with a toothbrush. Excessive or abrasive brushing can damage the probe and void the warranty. If necessary you can dip the brush, but not the probe, into rubbing alcohol. To dry the probe, bake it for a minimum of two hours at 150-200 F (66-93 C). Baking at temperatures above 200 F (93 C) can damage the cord and void the warranty. Contacting Fluke For application or operation assistance, or information on Fluke products, call: USA: 1-888-44-FLUKE (1-888-443-5853) Canada: 1-800-36-FLUKE (1-800-363-5853) Europe: +31 402-675-200 Japan: +81-3-3434-0181 Singapore: +65-738-5655 Anywhere in the world: +1-425-446-5500 For USA Service: 1-888-99-FLUKE (1-888-993-5853) Or, visit Fluke's Web site at www.fluke.com. To register your product, visit register.fluke.com

ONE YEAR LIMITED WARRANTY This Fluke product will be free from defects in material and workmanship for one year from the date of purchase. This warranty does not cover fuses, disposable batteries, or damage from accident, neglect, misuse, alteration, contamination, or abnormal conditions of operation or handling. Resellers are not authorized to extend any other warranty on Fluke s behalf. To obtain service during the warranty period, contact your nearest Fluke authorized service center to obtain return authorization information, then send the product to that Service Center with a description of the problem. THIS WARRANTY IS YOUR ONLY REMEDY. NO OTHER WARRANTIES, SUCH AS FITNESS FOR A PARTICULAR PURPOSE, ARE EXPRESSED OR IMPLIED. FLUKE IS NOT LIABLE FOR ANY SPECIAL, INDIRECT, INCIDENTAL OR CONSEQUENTIAL DAMAGES OR LOSSES, ARISING FROM ANY CAUSE OR THEORY. Since some states or countries do not allow the exclusion or limitation of an implied warranty or of incidental or consequential damages, this limitation of liability may not apply to you. Fluke Corporation P.O. Box 9090 Everett, WA 98206-9090 U.S.A. Fluke Europe B.V. P.O. Box 1186 5602 BD Eindhoven The Netherlands 11/99