K Standard Grade Ni-Cr vs Ni-Al (Chromel vs Alumel)



Similar documents
80PK-27 SureGrip TM Industrial Surface Temperature Probe

The table below lists the symbols used on the Clamp and/or in this manual. Important Information. See manual.

i410/i1010 AC/DC Current Clamp

CO-220 Carbon Monoxide Meter

How To Use The Visifault Visual Fault Locator

Temperature Humidity Meter

MicroScanner 2. Cable Verifier. Getting Started Guide

HVAC Clamp Meter. Users Manual

62 Max/62 Max + Infrared Thermometer

EPM3. Phase Sequence and Motor Rotation Tester. Users Manual


MICROMAPPER. Users Manual. LAN Wiremap Checker

New thermometers and accessories to grow your business

5616 Platinum Resistance Thermometer User s Guide

323/324/325. Calibration Manual. Clamp Meter

1587/1577. Insulation Multimeters. Technical Data. Two powerful tools in one.

BUB-110B. Portable Power Pack. Compact USB Battery Charger for up to 5 Smartphones and Mobile Devices. User Manual

Advantium 2 Plus Alarm

CM100. Carbon Monoxide Meter. Users Manual Mode d emploi Bedienungshandbuch Manual d Uso Manual de uso Användarhandbok

Multifunction Process Calibrator

10 Multimeter. Users Manual

A99B Series Temperature Sensors

MGO Insulated Thermocouples Index

Instructions & Safety Information Models A220-20D and A220-20L Version 2

Troubleshooting Guide, Freedom and Fleet Power Inverter/Chargers

Troubleshooting HVAC/R systems using refrigerant superheat and subcooling

Model HPX10 Series Automatic Battery Charger User s Manual Rev. 1.0 October 17, 2006

Laptop Power Adapter for home/office User Manual

Product Data Sheet 3M Mini-Clamp II Plug and Socket Wiremount Connectors

Loop Calibration and Maintenance

REDI-LINE ELECTRIC GENERATORS USER'S GUIDE. Rugged, Reliable, DC to AC Power Conversion

Single Station Remote Alarm

Fossil fuel heating equipment

Operating Manual UWAPS-TINY Series

user s manual Battery Case model #: SPB3200 Battery Case Charger for Samsung Galaxy S 4

How To Use A Cdm250 Digital Multimeter

SOLAR ELECTRIC MODULE ES-124 & ES-62T Owners Manual and Installation Guide

Users Manual. Temperature Calibrator

6/14/02 Chapter 14: Use of Electrical Test Equipment 1/20

Product data sheet. JUMO MIDAS Pressure Transmitter. Sales No. Order code JUMO AS /

FLEX by 3M Light Module System

Thermocouple Thermometer Models

OPERATING MANUAL CONTRACTOR STYLE AXIAL FANS

LED...A Q Series Sealed High-Intensity

DUSTTRAK AEROSOL MONITOR SOLAR POWER KIT MODEL

Toroidal Conductivity Sensor

Model UT713 OPERATING MANUAL

3M High Flex Life Cable.050" 28 AWG Stranded, PVC 3319 Series

DTM04 TANK MONITOR DTM08 TANK MONITOR Dtm12 TANK MONITOR. Installation and Operation Manual

Universal Laptop Charger

Threaded Inline Air Heaters

USB TC-08. Temperature Logger. User's Guide. usbtc08.en r7 Copyright Pico Technology Limited. All rights reserved.

When any of the following symbols appear, read the associated information carefully. Symbol Meaning Description

User Manual (English)

PRESSURE AND TEMPERATURE SENSORS for use with the BURNERLOGIX Burner Management System and PPC4000 Series Fuel/Air Ratio Controller

Heat Tracing is the use of an externally applied heat source to a pipeline to compensate for heat losses through the thermal insulation.

RGC-IR Remote Gas Calibrator for IR400

Cables and Accessories Selection Guide

3M Twisted Pair Flat Cable.050" 28 AWG Stranded, Mass Terminatable Pair, PVC 1700 Series

Air Sensor. SAC Ex. Manual ATEX. AQ Elteknik AB

ABCs of DMMs Multimeter features and functions explained Application Note

, User s Manual

Vehicle Brake System Monitoring 2-wire, 4-20 ma option; Intrinsic Safety Approval to E Exia IIC T4 (Tamb=60 C) BASEEFA, CENELEC EN50-020

User Guide. HDMI Active Cable Extender. DVI-7370c

Part I - Installation

Installation and Operation Manual. Digital Remote Meter for Monitoring System Performance. Version: RM-1

AGS. Owner's Manual. Xantrex Automatic Generator Start Control System

ABB Drives. User s Manual. Pulse Encoder Interface Module RTAC-01

Weatherproofing Coaxial Cable Connections

Signal Manager Installation and Operation Manual

RI-215A Operator s Manual. Part Number: RK Revision 0 Released: 10/3/05

HDTV. Amplified Indoor Outdoor Antenna. indoor outdoor. 10 db Amplification. Paintable. Versatile TERRESTRIAL VHF UHF

Physical. Electrical. Environmental. Insulation: Contact: Plating: Temperature Rating: -55 C to +85 C

Model 77 Series IV Digital Multimeter

Nest Learning Thermostat Installation Guide. Installation step-by-step

Digital echo-charge. Owner s Manual. Xantrex Digital echo-charge Battery Charger

Thick Film Resistor Networks, Dual-In-Line, Molded DIP

Tina 2A/B Adaptor unit

Featuring EP1 EARPHONES. Owner s Manual

3M Serial Attached SCSI (SAS) Connector Boardmount Compliant Pin and Surface Mount, Vertical Receptacle

Using Thermocouple Sensors Connecting Grounded and Floating Thermocouples

INSTALLATION AND OPERATING INSTRUCTIONS

Instructions A Amp AC/DC Current Probe

16/32 Channel 1U Rack Mount CCTV Power Supply

DUAL%CHANNEL BROADBAND%LINEAR%AMPLIFIER Model&A800D

FriendlyNet Hub 5-Port or 8-Port Ethernet Hub User s Manual

Wireless Indoor/ Outdoor Thermometer

AXIS T81B22 DC 30W Midspan

Multimeter measurements on variable frequency drives using the new Fluke 289 DMM

VAQ. Built-in V-series Miniature Basic Switch for Compatibility with Business and Consumer Equipment. Pushbutton Switch (Cylindrical 10.5-dia.

The Bose 601 TM Series IV Direct/Reflecting Speaker System

Mini Power Bank and Charger

READ FIRST! Universal Car/Air Adapter User Manual

Advanced Systems Tester 900AST

Automatic taper of charge rate for superior battery life through good equalization of cells and low water use rate.

Stretch DisplayPort TM

Thermistor Thermometer MODEL NO

Transcription:

SureGrip TM 80PK-24 Air Temperature Probe Instruction Sheet XWWarning To avoid electrical shock, do not use this probe when voltages exceeding 24 V ac rms or 60 V dc are present. The probe tip is electronically connected to the output terminals. Introduction The 80PK-24 SureGripTM Air Temperature Probe is designed for measuring the temperature of air or gases. The measuring bead of the probe is protected by a perforated 304 Stainless Steel baffle to prevent accidental damage. The sheath material is 300 Stainless Steel. The 38-inch (1 meter) cable is terminated with a Type K miniature thermocouple connector with 0.792-mm (.312-in) pin spacing. The 80PK-24 can be used with any temperature-measuring instrument that is designed to accept Type K thermocouples and has a miniature connector input. Specifications Type K Standard Grade Ni-Cr vs Ni-Al (Chromel vs Alumel) Measurement Range -40 C to 816 C (-40 F to 1500 F) Accuracy (With respect to ANSI MC96.1-1982-Standard Limits of Error): Note All error calculations should be done in C, then scaled to F. Range -40 C to 293 C (-40 F to 559.4 F) 293 C to 816 C (559.4 F to 1500 F) ±2.2 C ±0.75 % Accuracy (% of reading) November 2004 Rev.2, 9/09 2004-2009 Fluke Corporation. All rights reserved. All product names are trademarks of their respective companies

Output @ 25 C (77 F) =1.00 mv (reference junction @ 0 C) Seebeck Coefficient @ 25 C (77 F) =40.50 μv / C Measurement Time (Time Constant) 3.0 seconds in 100 C air moving at 3.33 meters/second (10.9 feet/ second) at sea level pressure (5 time constants = 1 complete step change, i.e., 15 seconds). Maximum Voltage: 24 V ac rms or 60 V dc Maximum Temperature of Tip: 816 C (1500 F) Baffle Material: 304 Stainless Steel Dimensions Diameter: 3.81 mm (0.150 in) Length: 3.3 cm (1.3 in) Sheath Material: 304 Stainless Steel Dimensions Diameter: 3.175 mm (0.125 in) Length: 215.9 mm (8.5 in) from handle body to end of baffle Grounding Junction welded to sheath. Cable Length: 38 inches (1 meter) Insulation Material: PVC Maximum Temperature: 105 C (220 F) Jacket Color: Gray Conductors Type: K Size: AWG #24 stranded (7 strands of #32) Handle Material: Hytrel Maximum Temperature: 125 C (257 F) Connector Type: Mini-thermocouple connector with.792 mm (0.312 in) pin spacing Material: Yellow Hytrel Maximum Temperature: 125 C (257 F) Overall Length 31.9 cm (12.55 in) from baffle tip to end of cable strain relief. Protection Class 3. Relates solely to insulation and grounding properties defined in IEC 348.

Measurement Considerations Instrument Compatibility The 80PK-24 is compatible with any temperaturemeasuring instrument that accepts Type K thermocouples, has a miniature thermocouple connector, and has cold reference junction compensation. Accuracy of the temperature-measuring instrument must be considered along with the 80PK-24 accuracy specification to determine the overall accuracy of the combination. Temperature Limitations The baffle tip of the 80PK-24 has a continuous temperature rating of 816 C (1500 F). However, the opposite end of the sheath nearest the handle should not be subjected to temperatures greater than 125 C (257 F). This is the maximum temperature limitation of the handle. Media Limitations The stainless steel baffle and sheath should not be exposed to halides or sulfides. Even though the sheath to junction transition is sealed, it is not recommended to immerse the probe in liquid or saturated vapor. The 80PK- 24 should not be used in reducing atmospheres or in a vacuum. Operation Use the 80PK-24 as follows: 1. Use the miniature (0.312-inch spacing) thermocouple connector to connect the 80PK-24 to a compatible Type K temperature-measuring instrument. 2. Turn on the measuring instrument, and select the appropriate range and scale. 3. Check the read out on the measuring instrument. With no heat or cold source applied to the tip of the probe, the measuring instrument should display the ambient (room) temperature. If the instrument does not read out properly, refer to Troubleshooting. Minimizing Thermal Shunting The 80PK-24 Air Probe should be inserted at least 6.35 cm (2.5 in) into the environment to be measured to minimize the shunting effect of the sheath.

Troubleshooting With no heat or cold applied to the probe, the measuring instrument should display the ambient temperature. If the measuring instrument does not read out properly, try the following: 1. Verify that the temperature-measuring instrument is designed to be used with Type K thermocouples. The temperature-measuring instrument should have a yellow input connector and / or be marked with a K. 2. Check for an open circuit indicator on the measuring instrument. Some temperature measuring instruments have a built-in circuit to indicate if the connected probe is open. (All Fluke Temperature-measuring instruments have this feature.) Refer to the owners manual accompanying the measuring instrument to see if this feature is available. Short the two input pins of the measuring instrument with a piece of wire. If the instrument is functioning, it should indicate the ambient temperature. 3. If you suspect a broken connection, use an ordinary ohmmeter to read the continuity of the probe from pin to pin. The ohmmeter should read 20 ohms or less if there is continuity. Scale Conversions Use the following equation to convert C to F: ( C x 1.8) + 32 = F Use the following equation to convert F to C: ( F 32) x 0.5556 = C 8.5" (215.90 mm) Diameter:.125" (3.175 mm) Diameter:.150" (3.81 mm) Figure 2. 80PK-24 bag01f.eps

Contacting Fluke For application or operation assistance, or information on Fluke products, call: USA: 1-888-44-FLUKE (1-888-443-5853) Canada: 1-800-36-FLUKE (1-800-363-5853) Europe: +31 402-675-200 Japan: +81-3-3434-0181 Singapore: +65-738-5655 Anywhere in the world: +1-425-446-5500 For USA Service: 1-888-99-FLUKE (1-888-993-5853) Or, visit Fluke's Web site at www.fluke.com. To register your product, visit register.fluke.com ONE YEAR LIMITED WARRANTY This Fluke product will be free from defects in material and workmanship for one year from the date of purchase. This warranty does not cover fuses, disposable batteries, or damage from accident, neglect, misuse, alteration, contamination, or abnormal conditions of operation or handling. Resellers are not authorized to extend any other warranty on Fluke s behalf. To obtain service during the warranty period, contact your nearest Fluke authorized service center to obtain return authorization information, then send the product to that Service Center with a description of the problem. THIS WARRANTY IS YOUR ONLY REMEDY. NO OTHER WARRANTIES, SUCH AS FITNESS FOR A PARTICULAR PURPOSE, ARE EXPRESSED OR IMPLIED. FLUKE IS NOT LIABLE FOR ANY SPECIAL, INDIRECT, INCIDENTAL OR CONSEQUENTIAL DAMAGES OR LOSSES, ARISING FROM ANY CAUSE OR THEORY. Since some states or countries do not allow the exclusion or limitation of an implied warranty or of incidental or consequential damages, this limitation of liability may not apply to you. Fluke Corporation P.O. Box 9090 Everett, WA 98206-9090 U.S.A. Fluke Europe B.V. P.O. Box 1186 5602 BD Eindhoven The Netherlands 11/99