Stainless Steel Dissolved Oxygen Electrodes



Similar documents
Dissolved Oxygen Sensors

DISSOLVED OXYGEN PROBE

OXIGENO DISUELTO. Dissolved Oxygen. Install & forget. Sistema autolimpiable. Autoclean system

JUMO BlackLine CR-GT/-EC/-GS Conductive 2-Electrode Conductivity Sensor

User Guide. Heavy Duty Dissolved Oxygen Meter. Model

Product data sheet. JUMO MIDAS Pressure Transmitter. Sales No. Order code JUMO AS /

Stainless steel process fittings

Galvanic Parts Per Million Dissolved Oxygen Systems

User Guide Dissolved Oxygen Probes

Turbine Flow Sensor Series VTR

Milwaukee USER MANUAL

OxyGuard. Dissolved Oxygen Probe

OPERATION MANUAL. Pen type, separate electrode SOIL PH METER Model : PH-220S

Trace Dissolved Oxygen Sensor

Resolution selectable from 0.01 and ph. Range ph. Accuracy ± ph

VISIFERM DO. Optical Oxygen Sensors with Integrated Transmitter THE MEASURE OF EXCELLENCE

TB2CS Conductivity sensor 2-Electrode. Superior accuracy in low level conductivity measurement ranges

A full spectrum of custom cables

Retractable Housings. InTrac 781 / 784 Versatile and Rugged For the Toughest Process Conditions INGOLD

ELECTROCHEMISTRY. BOECO ELECTRODES The electrodes are not included with the ph meters and have to be ordered separately:

Ozone Sensor. Model 499A OZ CAUTION CAUTION. Instruction Sheet PN 51A-499AOZ/rev.F January 2007

Solenoid Valve Island Type 3965

Electronic pressure switch with display Model PSD-30, standard version Model PSD-31, with flush diaphragm

Direct Measurement Method Method to 20.0 mg/l (or 0 to 200% saturation) O 2 Clark-type Amperometric Sensor

DISSOLVED OXYGEN METER Model : DO-5509

Relative and absolute pressure switch type 529

MTI10 Insertion and MTL10 In-line Thermal Mass Flowmeter and Temperature Transmitter

User's Manual. Heavy Duty Dissolved Oxygen Meter Model

Incubator with mechanical convection

Differential-Hall-Effect based Sensors Series A5S

Typical Aluminum GFM Mass Flow Meter

Mass Flow Meters & Controllers

For additional information, please visit our website at

General Purpose ph/orp Sensors

STANDARD OPERATING PROCEDURE Dissolved Oxygen Measurement, Meter Calibration and Maintenance

Cajon VCR Fittings. Flanges, Fittings, & Components. Cajon & Swagelok Fittings. Cajon VCR Fittings. Nuts, Caps, & Plugs. Socket Weld Glands

Assisted lift operated 2/2-way solenoid valves Type EV250B

SenTix 950 SenTix 980

Amphenol Fiber Systems International

Pipe threads for tubes and fittings where pressure-tight joints are not made on the threads. (requires PTFE sealing tape or liquid sealant).

Heating oven with mechanical convection

The Unique Accelabar Flow Meter

Safety at a high level!

Vehicle Brake System Monitoring 2-wire, 4-20 ma option; Intrinsic Safety Approval to E Exia IIC T4 (Tamb=60 C) BASEEFA, CENELEC EN50-020

Ferrostat Speed Sensor Series DSF Explosion Proof Versions EEx

VE 210. Velocity transducer for low-frequency measurements. » From the Vibro-Meter product line» Low-frequency compensation allows frequency

PMP 4000 Series. Druck Amplified Output Pressure Transducers. GE Sensing. Applications. Features

Heating oven with mechanical control

Electronic Pressure Monitoring New Products

Climate chamber with illumination

DissolvedOxygenMonitor

Improving Temperature Measurement to Optimize Inventory Control and Custody Transfer Systems

User's Guide. ExStik DO600. Dissolved Oxygen Meter RECALL. Dissolved Oxygen DO600

BM SERIES WAVE COMPACT 6.3 GHZ CW SERIES PULSE RADAR LEVEL INSTRUMENTS (6.3 GHz)

DiwiTherm, Resistance Thermometers Model TR75, with digital Display Battery or Solar Powered

Pressure transmitter For general industrial applications Model A-10

Electronic Pressure Switch EDS 300

Models SFP33 & SFP32 Pressure Transmitters

Digital inductive conductivity transmitter

14 PHOENIX CONTACT Courtesy of Power/mation Energy Lane, Saint Paul, MN

Product Data. Model 575 Series Submersible Level Transmitters ELECTRONIC PRESSURE MEASUREMENT PRODUCTS DESCRIPTION FEATURES APPLICATIONS

LED...A Q Series Sealed High-Intensity

Thermal flow sensors TA10-ZG8c and TA10-ZG9c for exact and stable, long-term measuring of lower flow velocities (Laminar Flow)

Amphenol C 091 A/B/D. Circular Connectors. Amphenol-Tuchel Electronics GmbH

COMBIMASS. Technical Data COMBIMASS eco-bio +

Application Guide to RF Coaxial Connectors and Cables

Dimensions. LUC-M20 with F12 housing and process connection 2" approx. 86 AF60 G2 2 NPT Ø50. Additional dimensions see section dimensions.

Material test chamber with mechanical convection

Replacing Displacers with Guided Wave Radar

mpm DIN CONNECTORS

FLEXIBLE SOLUTIONS FOR FLUIDS AND GASES

Position Transducers with Restoring Spring 10, 25, 50, 75, 100 mm TR, TRS Series

Instruction Manual HI Portable Waterproof Microprocessor Dissolved Oxygen Meter

Milwaukee USER MANUAL. Milwaukee. Smart DO Meter PORTABLE DISSOLVED OXYGEN METER MODEL: SM600. Authorized Dealer: ISMIL600 11/01

Combustion Dynamics Instrumentation

Instructions Manual. Electromagnetic sensor Series FLOMID FX. instrumentation for fluids. R-MI-FlomidFX Rev.: 0 English version

Roxar Electrical Resistance (ER) Probes 2 Retrievable System

Quick Connect. RTDs, Cordsets and Transmitter with M12 Connections

Torque Transducers MEASURING ELECTRONIC

Electromagnetic Flow Meter

Description. Specifications and Ordering Information and Accelerometer Acceleration Transducers

DL AND DBA SERIES CONNECTORS QUALIFIED TO MIL-DTL SERIES III Weight-saving aluminum connectors designed for rugged use and high temperatures

How To Use A Corona Mdi 110

Our full line of JS Popper test products enables you to monitor circuits without taking them offline

Industrial circular connectors

GAS DISTRIBUTION PRODUCTS STEEL SERVICE TEES

Fluid Level Gauge Fluid Level Sensor Temperature Switch FSA / FSK / TS

Single sub-base valve

9000 Series Accelerometers Specifications

Reaction Torque Sensor

LED LEONARDO 120 W. LED Fresnel SPOTLIGHT White light, either Tungsten or Daylight balanced Correlated Color Temperature

RTD Temperature Probe for the Food/Pharmaceutical Industry

DMP 331. Industrial Pressure Transmitter for Low Pressure. Stainless Steel Sensor

RPS High Accuracy Resonant Pressure Sensor. GE Measurement & Control Solutions. Features:

HygroClip 2 (HC2) Humidity Temperature Probes User Guide

SITRANS F flowmeters SITRANS F M

EMC Test Chamber Solutions RF Cable Assemblies and Connectors

Control- and feedback head for integrated mounting on Robolux valves Type 2036

SOURIAU s discrete wire sealing

Pipe Temperature Sensors

Transcription:

Stainless Steel Dissolved Oxygen Electrodes DISSOLVED OXYGEN ELECTRODES The steam sterilizable family of dissolved oxygen electrodes from the phoenix Electrode Company is specifically designed for fermentation where it is necessary to subject electrodes to repeated steam sterilization. Dissolved oxygen electrodes are available in both polarographic and galvanic styles to fulfill all requirements. phoenix O 2 electrodes are compatible with most common O 2 s found in fermentation. electrodes are designed to be used with phoenix Electrode Company, Ingold IL, Cole-Parmer and Applikon O 2 s, or with other s that are designed to be used with Ingold dissolved oxygen electrodes. Galvanic electrodes are designed to be used with phoenix Electrode Company, New Brunswick Scientific, LSL Biolafitte and Applikon O 2 s. The DO probes are available for laboratory fermentation where sterilization takes place in a separate autoclave or industrial applications where sterilization takes place in-situ. The easily replaced electrode membrane cartridge is a unique feature of the phoenix polarographic and NBS galvanic dissolved oxygen electrodes. The membrane is of a special construction - a silicone and teglon composite, reinforced with stainless steel mesh. This unique membrane is very rugged and allows for repeated sterilization without damage, allowing ot to withstand severe conditions. The electrode operates without maintenance for 5 to 10 sterilizations, fermentation cycles or, in terms of time, for 6 to 8 weeks. The phoenix Biolafitte type galvanic dissolved oxygen electrode features easily replaceable FEP teflon membranes. The polarographic dissolved oxygen electrodes are available with or without automatic temperature compensation. They are designed to match the Ingold IL oxygen. Temperature compensation is not normally required when calibration is made at the same temperature as the controlled fermentation temperature with no variation.

SPECIFICATIONS A B C A1 A2 A3 A4 A5 OXYGEN ELECTRODE ASSEMBLY MOUNTINGS D E F G A. Detachable Lead B. O-ring Seal C. 316L Stainless steel body D. O-ring E. Anode F. Membrane Cover G. Replacement Membrane Cartridge H. O-ring I. Cathode FIGURE A1 A2 A3 A4 TYPE 07 05 03 01 DESCRIPTION 19mm socket flange M18 x 1.5 3/4 NPT 3/8 NPT BODY DIAMETER 16 mm 14 mm H I A5 08 25mm socket flange 10 No Thread 12 mm 11 PG 13.5 12 mm

SPECIFICATIONS TYPE CATHODE ANODE RESPONSE STABILITY 1 COMPENSATION RANGE STERILIZATION RESIDUAL SIGNAL OUTPUT 2 025IP25 025IP26 025IP27 025BG25 Galvanicic Ag Pb 35mV + 10mV 025IP25 NO YES YES NO NO 0-80 C 0-80 C 0-80 C 0-80 C 0-80 C 130 C 130 C 130 C 130 C 130 C Less Than 1 na Less Than 1 na Less Than 1 na 0.5-1 mv Less Than 0.4 µa 1 = Constant Temperature 2 = Medium Saturated With Air ORDERING INFORMATION 025IP 025BG 025NG Sensor Type Stainless Steel Galvanic, LSL Biolafitte phoenix and Applikon Compatible, Stainless Steel Galvanic, New Brunswick Scientific Compatible, Stainless Steel 25 26 27 Temperature Compensation No Temperature Compensation Temperature Compensated Ingold Amplifier Temperature Compensated phoenix Electrode Company, Cole-Parmer, and B&C Electronics 01 03 05 07 08 10 11 Mounting 3/8 NPT Male Thread (For NBS Headplate), 14 mm Body Diameter. 3/4 NPT Male Thread, Body Diameter. M18 x 1.5 Male Thread (For LSL Biolafitte and Applikon Headplate), 16 mm Diameter. Socket Flange, Body Diameter. 25 mm Socket Flange, Body Diameter. 12 mm Body Diameter Straight Body. 12 mm Body Diameter with PG 13.5 Thread. 025IP - 25-150 - 05 EXAMPLE: 025IP25-150-05 (, No Temperature Compensation, H Length, and Mounting.) 70 mm 120 mm 150 mm 220 mm 320 mm 420 mm XXX mm H Length H Length (Immersion length is the distance from the point of penetration inside the vessel to the tip of the probe.) 08 Mounting 10 and 03, 05, 07 and 08 Mountings 03, 05, 07, 08, 10 and 03, 05, 07, 08, 10 and 05, 07, and 08 Mountings Special Order H Length 70 mm 150 mm 220 mm 320 mm 420 mm 440 mm Galvanic (LSL Biolafitte Fermentor) 08 Mounting 05, 08, 10 and 05, 10 and 05, 10 and 05 Mounting 05 Mounting 127 mm 186 mm 229 mm 308 mm 355 mm 360 mm 432 mm 559 mm 711 mm Galvanic (NBS Fermentor) 01, 08, 10 and 01, 08, 10 and 01, 08, 10 and

MEMBRANE SERVICE KITS AND MEMBRANES POLAROGRAPHIC TYPES M0500P1-K1 M0500P1-K2 M0500P1-K5 M0500P1-M1 M0500P2-M2 M0500P2-M6 R001068 GALVANIC TYPES M050BG1-K3 M050NG1-K4 M050NG1-K1 M050BG2-M3 M050BG2-M5 M050NG2-M4 M050NG1-M1 R001069 Membrane Service Kit for O 2 electrodes with 3/4 NPT, or 25 mm mounting with O.D. body diameter. Consists of replacement O-rings, 3 replaceable membrane cartridges, Membrane Service Kit for O 2 electrodes with M18 x 1.5 mounting with 16 mm O.D. body diameter. Consists of replacement O-rings, 3 replaceable membrane cartridges, Membrane Service Kit for O 2 electrodes with PG 13.5 or 12 mm mounting with 12 mm O.D. body diameter. Consists of replacement O-rings, 3 replaceable membrane cartridges, Replacement Membrane consists of one membrane cartridge and replacement O-rings for 3/4 NPT, or 25 mm mounting, O.D. body diameter. Replacement Membrane consists of one membrane cartridge and replacement O-rings for M18 x 1.5 mounting, 16 mm O.D. body diameter. Replacement Membrane consists of one membrane cartridge and replacement O-rings for PG 13.5 or 12 mm mounting, 12 mm O.D. body diameter. O 2 electrode filling solution, 125 ml electrodes with M18 x 1.5, or 25 mm socket with 16 mm O.D. body diameter. Consists of 10 membranes (5 each of 1 and 2 mil), replacement O-rings, electrodes with 3/8 NPT mounting with 14 mm O.D. body diameter. Consists of replacement O-rings, 3 replaceable membrane cartridges, tool, and a 125 ml bottle of electrolyte. electrodes with PG 13.5 or 12 mm mounting with 12 mm O.D. body diameter. Consists of replacement O-rings, 3 replaceable membrane cartridges, tool, and a 125 ml bottle of electrolyte. Replacement Membrane consists of 10 membranes 1 mil thick and replacement O-rings for M18 x 1.5, and 25 mm mountings, 16 mm O.D. body diameter. Replacement Membrane consists of 10 membranes 2 mil thick and replacement O-rings for M18 x 1.5, and 25 mm mountings, 16 mm O.D. body diameter. Replacement Membrane consists of one membrane cartridge and replacement O-rings for 3/8 NPT mounting, 14 mm O.D. body diameter. Replacement Membrane consists of one membrane cartridge and replacement O-rings for PG 13.5 or 12 mm mounting, 12 mm O.D. body diameter. Galvanic O 2 electrode filling solution, 125 ml CABLES C1 TYPE CABLES For non-temperature compensated O 2 electrodes, used with both polarographic and galvanic O 2 electrodes. Standard 3 meter lead. 9001091-010B 9001091-010I 9001091-010D 9001091-010U 9001091-010T 9001091-010CC 9001093-010D 9001096-010D 9001096-003 BNC Connector DIN Connector for use with Ingold po 2 Dual Pin Connector for use with NBS Galvanic po 2 Banana Plugs for use with LSL Biolafitte po 2 No Connector for phoenix, Applikon, and Cole-Parmer po 2 s or for use when user supplies connector Custom cable with choice of plug, lemo connector. Specify size and pin nimber Pin Connector, for use with 025NG15 and 027NG15 Galvanic O 2 electrode. Cable features a load resistor for direct connection to a recorder with mv input. (Approx. 40 mv saturated air / water) Amphenol4-Pin Electrode head connector for use with NBS po 2 Amphenol detachable lead to Amp 4-Pin connector for use with NBS po 2

C2 TYPE CABLES For polarographic temperature compensated O 2 electrodes. Standard 3 meter lead. 9001092-010I 9001092-010T 9001092-010CC 9001097-003 DIN Connector + pins for use with Ingold po 2 No Connector for phoenix, Applikon and Cole-Parmer po 2 s, or for use when user supplies connector Custom cable with choice of plug type, lemo connector. Specify plug size and pin number Amphenol 4-Pin Electrode head connector to Amp 4-Pin Connector. For polarographic electrodes, NBS Note: Longer lead lengths are available on special order. 6103 Glenmont Houston, Texas 77081 800/522-7920 713/772-6666 Fax 713/772-4671 http://www.phoenixelectrode.com