Stainless Steel Dissolved Oxygen Electrodes DISSOLVED OXYGEN ELECTRODES The steam sterilizable family of dissolved oxygen electrodes from the phoenix Electrode Company is specifically designed for fermentation where it is necessary to subject electrodes to repeated steam sterilization. Dissolved oxygen electrodes are available in both polarographic and galvanic styles to fulfill all requirements. phoenix O 2 electrodes are compatible with most common O 2 s found in fermentation. electrodes are designed to be used with phoenix Electrode Company, Ingold IL, Cole-Parmer and Applikon O 2 s, or with other s that are designed to be used with Ingold dissolved oxygen electrodes. Galvanic electrodes are designed to be used with phoenix Electrode Company, New Brunswick Scientific, LSL Biolafitte and Applikon O 2 s. The DO probes are available for laboratory fermentation where sterilization takes place in a separate autoclave or industrial applications where sterilization takes place in-situ. The easily replaced electrode membrane cartridge is a unique feature of the phoenix polarographic and NBS galvanic dissolved oxygen electrodes. The membrane is of a special construction - a silicone and teglon composite, reinforced with stainless steel mesh. This unique membrane is very rugged and allows for repeated sterilization without damage, allowing ot to withstand severe conditions. The electrode operates without maintenance for 5 to 10 sterilizations, fermentation cycles or, in terms of time, for 6 to 8 weeks. The phoenix Biolafitte type galvanic dissolved oxygen electrode features easily replaceable FEP teflon membranes. The polarographic dissolved oxygen electrodes are available with or without automatic temperature compensation. They are designed to match the Ingold IL oxygen. Temperature compensation is not normally required when calibration is made at the same temperature as the controlled fermentation temperature with no variation.
SPECIFICATIONS A B C A1 A2 A3 A4 A5 OXYGEN ELECTRODE ASSEMBLY MOUNTINGS D E F G A. Detachable Lead B. O-ring Seal C. 316L Stainless steel body D. O-ring E. Anode F. Membrane Cover G. Replacement Membrane Cartridge H. O-ring I. Cathode FIGURE A1 A2 A3 A4 TYPE 07 05 03 01 DESCRIPTION 19mm socket flange M18 x 1.5 3/4 NPT 3/8 NPT BODY DIAMETER 16 mm 14 mm H I A5 08 25mm socket flange 10 No Thread 12 mm 11 PG 13.5 12 mm
SPECIFICATIONS TYPE CATHODE ANODE RESPONSE STABILITY 1 COMPENSATION RANGE STERILIZATION RESIDUAL SIGNAL OUTPUT 2 025IP25 025IP26 025IP27 025BG25 Galvanicic Ag Pb 35mV + 10mV 025IP25 NO YES YES NO NO 0-80 C 0-80 C 0-80 C 0-80 C 0-80 C 130 C 130 C 130 C 130 C 130 C Less Than 1 na Less Than 1 na Less Than 1 na 0.5-1 mv Less Than 0.4 µa 1 = Constant Temperature 2 = Medium Saturated With Air ORDERING INFORMATION 025IP 025BG 025NG Sensor Type Stainless Steel Galvanic, LSL Biolafitte phoenix and Applikon Compatible, Stainless Steel Galvanic, New Brunswick Scientific Compatible, Stainless Steel 25 26 27 Temperature Compensation No Temperature Compensation Temperature Compensated Ingold Amplifier Temperature Compensated phoenix Electrode Company, Cole-Parmer, and B&C Electronics 01 03 05 07 08 10 11 Mounting 3/8 NPT Male Thread (For NBS Headplate), 14 mm Body Diameter. 3/4 NPT Male Thread, Body Diameter. M18 x 1.5 Male Thread (For LSL Biolafitte and Applikon Headplate), 16 mm Diameter. Socket Flange, Body Diameter. 25 mm Socket Flange, Body Diameter. 12 mm Body Diameter Straight Body. 12 mm Body Diameter with PG 13.5 Thread. 025IP - 25-150 - 05 EXAMPLE: 025IP25-150-05 (, No Temperature Compensation, H Length, and Mounting.) 70 mm 120 mm 150 mm 220 mm 320 mm 420 mm XXX mm H Length H Length (Immersion length is the distance from the point of penetration inside the vessel to the tip of the probe.) 08 Mounting 10 and 03, 05, 07 and 08 Mountings 03, 05, 07, 08, 10 and 03, 05, 07, 08, 10 and 05, 07, and 08 Mountings Special Order H Length 70 mm 150 mm 220 mm 320 mm 420 mm 440 mm Galvanic (LSL Biolafitte Fermentor) 08 Mounting 05, 08, 10 and 05, 10 and 05, 10 and 05 Mounting 05 Mounting 127 mm 186 mm 229 mm 308 mm 355 mm 360 mm 432 mm 559 mm 711 mm Galvanic (NBS Fermentor) 01, 08, 10 and 01, 08, 10 and 01, 08, 10 and
MEMBRANE SERVICE KITS AND MEMBRANES POLAROGRAPHIC TYPES M0500P1-K1 M0500P1-K2 M0500P1-K5 M0500P1-M1 M0500P2-M2 M0500P2-M6 R001068 GALVANIC TYPES M050BG1-K3 M050NG1-K4 M050NG1-K1 M050BG2-M3 M050BG2-M5 M050NG2-M4 M050NG1-M1 R001069 Membrane Service Kit for O 2 electrodes with 3/4 NPT, or 25 mm mounting with O.D. body diameter. Consists of replacement O-rings, 3 replaceable membrane cartridges, Membrane Service Kit for O 2 electrodes with M18 x 1.5 mounting with 16 mm O.D. body diameter. Consists of replacement O-rings, 3 replaceable membrane cartridges, Membrane Service Kit for O 2 electrodes with PG 13.5 or 12 mm mounting with 12 mm O.D. body diameter. Consists of replacement O-rings, 3 replaceable membrane cartridges, Replacement Membrane consists of one membrane cartridge and replacement O-rings for 3/4 NPT, or 25 mm mounting, O.D. body diameter. Replacement Membrane consists of one membrane cartridge and replacement O-rings for M18 x 1.5 mounting, 16 mm O.D. body diameter. Replacement Membrane consists of one membrane cartridge and replacement O-rings for PG 13.5 or 12 mm mounting, 12 mm O.D. body diameter. O 2 electrode filling solution, 125 ml electrodes with M18 x 1.5, or 25 mm socket with 16 mm O.D. body diameter. Consists of 10 membranes (5 each of 1 and 2 mil), replacement O-rings, electrodes with 3/8 NPT mounting with 14 mm O.D. body diameter. Consists of replacement O-rings, 3 replaceable membrane cartridges, tool, and a 125 ml bottle of electrolyte. electrodes with PG 13.5 or 12 mm mounting with 12 mm O.D. body diameter. Consists of replacement O-rings, 3 replaceable membrane cartridges, tool, and a 125 ml bottle of electrolyte. Replacement Membrane consists of 10 membranes 1 mil thick and replacement O-rings for M18 x 1.5, and 25 mm mountings, 16 mm O.D. body diameter. Replacement Membrane consists of 10 membranes 2 mil thick and replacement O-rings for M18 x 1.5, and 25 mm mountings, 16 mm O.D. body diameter. Replacement Membrane consists of one membrane cartridge and replacement O-rings for 3/8 NPT mounting, 14 mm O.D. body diameter. Replacement Membrane consists of one membrane cartridge and replacement O-rings for PG 13.5 or 12 mm mounting, 12 mm O.D. body diameter. Galvanic O 2 electrode filling solution, 125 ml CABLES C1 TYPE CABLES For non-temperature compensated O 2 electrodes, used with both polarographic and galvanic O 2 electrodes. Standard 3 meter lead. 9001091-010B 9001091-010I 9001091-010D 9001091-010U 9001091-010T 9001091-010CC 9001093-010D 9001096-010D 9001096-003 BNC Connector DIN Connector for use with Ingold po 2 Dual Pin Connector for use with NBS Galvanic po 2 Banana Plugs for use with LSL Biolafitte po 2 No Connector for phoenix, Applikon, and Cole-Parmer po 2 s or for use when user supplies connector Custom cable with choice of plug, lemo connector. Specify size and pin nimber Pin Connector, for use with 025NG15 and 027NG15 Galvanic O 2 electrode. Cable features a load resistor for direct connection to a recorder with mv input. (Approx. 40 mv saturated air / water) Amphenol4-Pin Electrode head connector for use with NBS po 2 Amphenol detachable lead to Amp 4-Pin connector for use with NBS po 2
C2 TYPE CABLES For polarographic temperature compensated O 2 electrodes. Standard 3 meter lead. 9001092-010I 9001092-010T 9001092-010CC 9001097-003 DIN Connector + pins for use with Ingold po 2 No Connector for phoenix, Applikon and Cole-Parmer po 2 s, or for use when user supplies connector Custom cable with choice of plug type, lemo connector. Specify plug size and pin number Amphenol 4-Pin Electrode head connector to Amp 4-Pin Connector. For polarographic electrodes, NBS Note: Longer lead lengths are available on special order. 6103 Glenmont Houston, Texas 77081 800/522-7920 713/772-6666 Fax 713/772-4671 http://www.phoenixelectrode.com