This recommendation was prepared by the Technical Commission of EUROMAP.



Similar documents
EUROMAP 78. Electrical Interface between Injection Moulding Machines and External Safety Devices. Version 1.0, November pages

This recommendation was prepared by the Technical Commission of EUROMAP.

EUROMAP Injection Moulding Machines Determination of Product Related Energy Consumption. Version 3.0, January pages

EUROMAP Protocol for Communication with Peripheral Equipment. General Description

Combi B Alarm box. Mounting instructions

Pluggable interface relays CR-P Pcb relays

Safety detection solutions

Inductive Proximity Sensors

Switch Actuator, 8-fold, 10 A, MDRC AT/S , GH Q R0111

TECHNICAL DATASHEET Incremental Encoder RI 58-O / RI 58-T

mecotron Safety relay ESTOP-2 For emergency stop monitoring

Type: DILM115(RAC240) Article No.: Sales text Contactor,55kW/400V,AC operated. Ordering information

49 Series - Relay interface modules A. Features

Inductive Sensors Single or Dual Loop Detectors Type LD with teach-in

ABB i-bus KNX Switch Actuator, x-fold, 16 A, MDRC SA/S x , 2CDG1101xxR0011

TECHNICAL DATASHEET Incremental Encoder RI 80-E

pole, 8 A Safety relay. Screw terminal. 35 mm rail (EN 60715) mounting. 2 CO (DPDT) 8/15 250/400 2, /0.65/0.

Application Technique. Safety Function: Magnetic Door Switch Monitoring

EUROMAP Extrusion Blow Moulding Machines Determination of Machine Related Energy Efficiency Class. Version 1.0, January pages

60 Series - General purpose relays 6-10 A. Features

48 SERIES Relay interface modules 10 A

TECHNICAL DATASHEET Incremental Encoder RI 58-D / RI 58TD

PD30ETB20xxIS. Photoelectrics, Background Suppression reflective with IR light. Main features. Description

Your Advantages For safety application up to PL e / Cat. 4 e.g. SIL 3 Manual or automatic start * see variants. Applications.

Safety automation solutions

How To Control A Power Supply With A Mini Transmitter And Switch (Power Supply)

Proportional pressure regulators VPPE

HERZ-Thermal Actuators

Safety Relays ESM/ESM-F

Silvertel. Ag Features. 2 Description. Power-over-Ethernet Plus Module. IEEE802.3at and IEEE802.3af compliant. Maximum 30W output power

AC/DC Power Modules C B. TML Series, 20 & 40 Watt. Features. 20 Watt Models

DEUTSCHE NORM June Plastics Determination of flexural properties (ISO 178 : 2001) English version of DIN EN ISO 178

Safety technique. Emergency stop module BO 5988 safemaster

PTU Series Transducer Digital Display Indicator User s Manual

Shutter Actuator Standard, 4-fold, 230 VAC, MDRC RA/S , GH Q R0111. ABB i-bus EIB

OLI. Oil level indicator

Installation manual. Generator Paralleling Controller GPC multi-line C

Specifications for EM VDC 4 In/4 Out and EM VDC 4 In/4 Relay Out

How to set up EARTH FAULT ALARM On Fronius inverters

Contactless Encoder RI360P0-QR24M0-INCRX2-H1181

IBS IP KIS A. Data Sheet INTERBUS-S. Digital I/O Module

Operating Instructions for Plastic Flow Meter. Model: KSK

Copyrights 2010 Victron Energy B.V. All Rights Reserved

Digital display DA 48

T-SERIES INDUSTRIAL INCLINOMETER ANALOG INTERFACE

Documentation for. KL2602 and KL2622. Two-channel Relay Output Terminals for 230 V AC / 30 V DC. Version: 1.4 Date:

Product Information. Gateway For Connecting EnDat Encoders to PROFIBUS-DP

Contact expansion modules

EVC40 EMERGENCY VOICE COMMUNICATION SYSTEM

SMS 4 / SMS 5 safety mat Product information

NTE923 & NTE923D Integrated Circuit Precision Voltage Regulator

The Programming Interface

Electronic timer CT-VBS OFF-delayed without auxiliary voltage, for DC contactors Data sheet

HSP GmbH Zum Handwerkerhof Wendelstein Tel / Fax: / Web: HSP@hsshsp.de NTG-3000.

Valve series MN-06 acc. to NAMUR, 3/2-way G1/4 750 Nl/min (0.762 Cv)

Service & Support. Higher-level safe switch-off of the power supply of functionally nonsafe standard modules? Wiring Examples.

E-STOP relays, safety gate monitors

Field bus connections Link structure CMS link structure CMS, B-design. Brochure

40 Series - Miniature PCB/Plug-in relays A. Features

MICROSENS. Central 48 V DC Power Supplies for PoE-Components. Description. Features

Original instructions Tina 3A/Aps Adaptor unit

RY2 miniature industrial relays

0.8 U N /0.5 U N 0.8 U N /0.5 U N 0.8 U N /0.5 U N 0.2 U N /0.1 U N 0.2 U N /0.1 U N 0.2 U N /0.1 U N

ST Series POWER SUPPLIES USER INSTRUCTIONS

FDCI222, FDCIO222, FDCIO224 Input module Input/output modules

SYSTEM 45. C R H Electronics Design

PA5. Series. Quick-Connect Cables with Connectors. Simplifies sensor wiring. Wide variety of connectors attached to cables.

VEO. V4PF480Y/277VSYTK02 Art.Nr.: V4PF480Y/277VSYTK02P Art.Nr.: TECHNICAL DATA

MODULAR JUNCTION BOX MJB WITH GATEWAY

Charging connections for electric vehicles

DM74LS47 BCD to 7-Segment Decoder/Driver with Open-Collector Outputs

ABB STOTZ-KONTAKT GmbH ABB i-bus KNX Switch Actuators SA/S

Analog signal converters CC-E I/I Current / current isolators

Inductive sensor NI10-M18-Y1X-H1141


CONFIGURABLE SAFETY RELAYS

Enterphone Solo. User/Installation Manual Part No

AC ADAPTOR AC-550CE. MAINTENANCE MANUAL 1st Edition Serial No and Higher

MC10SX1190. Fibre Channel Coaxial Cable Driver and Loop Resiliency Circuit

ABB i-bus KNX Switch Actuator, x-fold, 16/20 A, MDRC SA/S x , 2CDG 110 1xx R0011

ABB i-bus KNX SA/S Switch Actuators Product Manual

Bimetallic Overload Relay Specifications

DS 600. A contact free flux gate based current measurement sensor 600A rms

DOCUMENTATION PD16 CP3-SVE-M75DC-24

Charge Controller CC611/CC612 Preliminary datasheet

Alarm over IP. IRIS Touch Home Installation Manual. Version 1.0 ENGLISH. Now certified and compliant with EN50131, EN50136 Security Grade 4 ATS6

General 1-2-Opto-electronics Safety Switches 4-Emergency

MM74C150 MM82C19 16-Line to 1-Line Multiplexer 3-STATE 16-Line to 1-Line Multiplexer

Inwall 4 Input / 4 Output Module

BNI EIP Z009 IP67 Module, Unmanaged Switch

Air damper actuators

Magnetic field sensor for pneumatic cylinders BIM-INT-Y1X-H1141

High Power Connectors for Power Supply and Power Circuits

.093 [2.36] Commercial Pin and Socket Connectors

Features. Applications. Truth Table. Close

Technical Data Sheet OPUS A3 STANDARD Full TDS OPUS A3sF,

CONNECTOR AMPLIFIER FOR PROPORTIONAL VALVES (4-20 ma Input Version)

F(t) Forssell Technologies Inc

DM74LS191 Synchronous 4-Bit Up/Down Counter with Mode Control

Power Supply and Indicator Unit Type Fig. 1 Type Mounting and Operating Instructions EB 9539 EN

Transcription:

EUROMAP 73 Electrical Interface between Injection Moulding Machines and External Safety Devices Version 1.1, May 2015 (8 pages) This recommendation was prepared by the Technical Commission of EUROMAP. Supplier's data corrected (v. 1.0a). List of plug suppliers removed (v. 1.1). Please visit www.euromap.org/technical-issues/technical-recommendations for the current list.

Content Page 1 Scope and Application... 3 2 Description... 3 2.1 Plug and socket outlets... 3 2.2 Contact specification... 4 2.2.1 Emergency stop, safety device... 4 2.2.2 Logical Signals... 4 2.2.3 Reference potential... 4 2.3 Plug contact assignment... 4 2.3.1 Table 1: Plug on the injection moulding machine (female)... 5 2.3.2 Table 2: Plug on the injection moulding machine (male)... 6 2.4 Sources of supply... 6 2.5 Schematic drawing of the interface... 7 EUROMAP 73 Page 2 of 8

1 Scope and Application This EUROMAP recommendation defines the connection between the injection moulding machine (IMM) and the external safety device, e.g. doors in fences around IMM, preventing access to the danger areas of the IMM with the possibility to reach into the area with high safety level specified in EN 201 "Plastics and rubber machines Injection moulding machines Safety requirements". This is intended to provide interchangeability. The interface is only used for the IMM, if other safety signals are necessary for other equipment, this falls under the responsibility of the user / integrator. In addition, recommendations are given for signal voltage and current levels. 2 Description The signals in both the injection moulding machine and the external safety device are given by contacts, e.g. contacts of relays or switches, semiconductors, etc. The contact making is either potential-free or related to a reference potential supplied to a contact of the plug mounted on the injection moulding machine (see Table 1). All signals which are not optional shall be supported by the injection moulding machine and external safety device. 2.1 Plug and socket outlets The connection between the injection moulding machine and the external safety device is achieved by the plugs specified below. For the injection moulding machine (see Figure 2) and the external safety device (see Figure 1) the plug contacts should be capable of taking a minimum of 250 V and 10 A. Arrangements of pins and sockets viewed from the mating side (opposite the wiring side) Figure 1: Plug on the external safety device Figure 2: Plug on the injection moulding machine EUROMAP 73 Page 3 of 8

2.2 Contact specification 2.2.1 Emergency stop, safety device - The voltages of the signals must not exceed 50V DC or 250V AC. - A current of at least 6 ma must be maintained during signalling. - The maximum current is 6A. 2.2.2 Logical Signals - These signals shall be in accordance with clause 3.3.1 of EN 61131-2, Table 9, Type 2 or with clause 3.3.3 of EN 61131-2,Table 11, max. 0,1 A unless otherwise specified. 2.2.3 Reference potential - Voltage 18 36V DC - Overlayed ripple max. 2,5Vpp - Withstand against overvoltage up to 60V min. 10 ms - Current max. 2A 2.3 Plug contact assignment Notes on the tables below: - All signals are continuous signals unless otherwise noted. - The signals are conducted from the signal source to the respective pin. EUROMAP 73 Page 4 of 8

2.3.1 Table 1: Plug on the injection moulding machine (female) Contact No.(female), see fig. 2 Contact name Signal designation Description c1/c3 c2/c4 S1 External safety device closed External safety device closed. Limit switch or safety switch is not actuated. c5/c7 c6/c8 S2 External safety device closed External safety device closed. Limit switch or safety switch is actuated. c9/c11 c10/c12 S3 External safety device closed External safety device closed. Limit switch or safety switch is not actuated. d1 Supply from injection moulding machine 24V DC / 2A d2 Supply from injection moulding machine 0V DC / 2A d3/d4 S4 Acknowledgement d5/d7 d6/d8 d9 Optional S0 S0 Emergency stop of safety device channel 1 Emergency stop of safety device channel 2 Unlock external safety device lock Signal of a manual switch or a safety circuit that all operators have left the protected area. Signal: Impulse, NO. The switch contact must be open when the external safety device emergency stop is being actuated. The switch contact opening causes emergency stop of the injection moulding machine. The switch contact must be active when the safety device is inactive. The switch contact must be open when the external safety device emergency stop is being actuated. The switch contact opening causes emergency stop of the injection moulding machine. The switch contact must be active when the safety device is inactive. High signal to the external safety device to unlock the external safety device. Maximum load 1A / 24V DC d10 Optional S5 Monitoring external safety device lock Contact is closed, if external safety device is closed and locked. d11 Optional S6 Request for external safety device opening A request-signal for external safety device opening. Signal: Impulse, NO. d12 Operation with external safety device Low signal when the external safety device is inactive. b1-b6 Spare Reserved for future use of EUROMAP. b7 b12 Spare Not fixed by EUROMAP, manufacturer dependent. NO: normally open NC: normally closed Note: S1,S2,S3 shall switch in a time period of 1s when the external safety device is closed (unclosed). EUROMAP 73 Page 5 of 8

2.3.2 Table 2: Plug on the injection moulding machine (male) Contact No (male), see fig. 2 Contact name Signal designation Description a1-a6 Spare Reserved for future use of EUROMAP. a7 a12 Spare Not fixed by EUROMAP, manufacturer dependent. 2.4 Sources of supply A list of plug suppliers is available for download on the EUROMAP website: www.euromap.org/technical-issues/technical-recommendations EUROMAP 73 Page 6 of 8

2.5 Schematic drawing of the interface EUROMAP 73 Page 7 of 8

EUROMAP Europäisches Komitee der Hersteller von Kunststoff- und Gummimaschinen European Committee of Machinery Manufacturers for the Plastics and Rubber Industries Comité Européen des Constructeurs de Machines pour Plastiques et Caoutchouc Comitato Europeo Costruttori Macchine per Materie Plastiche e Gomma See you again http://www.euromap.org Copyright by EUROMAP EUROMAP 73 Page 8 of 8