Digital Air Pressure Gauge Users Manual



Similar documents
User's Guide. Digital Psychrometer. Model RH390. F C WBT Dew Point MAX MIN

ExStik TM ph Waterproof Meters

OCS-S High Resolution Digital Crane Scale

Professional Thermohygrometer

User's Guide. Pinless Moisture Meter. Model MO257

psi fth mbar * /0.1 cmh inhg bar

4-Channel Thermometer / Datalogger

Hygro-Thermometer + InfraRed Thermometer Model RH101

CS5000 Users Manual. Intercomp Co County Road 116 Medina MN U.S.A.

TC-9102 Series Surface Mount Temperature Controllers

User Manual. Humidity-Temperature Chart Recorder. Model RH520

Light Meter (Foot Candles)

Instruction Manual Temp 4/5/6 Temperature Meter Series

Thermistor Thermometer MODEL NO

User Guide. Heavy Duty Dissolved Oxygen Meter. Model

User's Manual. Heavy Duty Dissolved Oxygen Meter Model

CruzPro VAF110. AC Volts, Amps, Frequency, kw Monitor

USER GUIDE. LED Light Meter. Model LT45

User's Guide. Digital Sound Level Meter. Model

My Weigh Ultraship Series User Manual

OPERATING INSTRUCTIONS SECURITY SYSTEM KIT NO.: 08E51-EP American Honda Motor Co., Inc. - All Rights Reserved. 1

User Guide. Model Insulation Tester / Megohmmeter

TECHANGLE November 30, 2005 TECHNICAL PAGE

User s Manual C R Y S T A L. engineering corporation

Digital pressure gauge for industrial applications Model DG-10-S, Standard version Model DG-10-E, Enhanced version

BODY FAT & HYDRATION % MONITOR SCALE

VOLTAGE/CURRENT CALIBRATOR ISO-TECH ILC-421

User Guide. ExStik TM ph (PH100 & PH110) and ORP (RE300) Waterproof Series Pens. Patent Pending

BW-500 BED WEIGHER USER MANUAL

Sensi TM. Wi-Fi Programmable Thermostat MANUAL OPERATION. Version: March Emerson Electric Co. All rights reserved.

HIGH PRECISION BALANCE MWP OWNER S MANUAL. MWP ver.1.0

OCSM Series. High Resolution Digital Crane Scale. User Guide

User Guide. Temperature and Humidity Datalogger. Model 42280

MAVO-MONITOR / MAVO-SPOT Instrument Set for Contact or Distant Measurements of Luminances

OPERATION MANUAL. Pen type, separate electrode SOIL PH METER Model : PH-220S

Ground Resistance Clamp On Tester

DC Electronic Loads 8500 series

OPERATION MANUAL MARSDEN-200 PLEASE TAKE THE TIME TO READ THESE INSTRUCTIONS BEFORE STARTING TO USE THE SCALES

12 Volt 30 Amp Digital Solar Charge Controller

10 Thomas, Irvine, CA USA Tel: (949) Fax: (949) Toll Free: (800) 23 FUTEK

1. SAFETY INFORMATION

Back-UPS Pro 1300/1500 Installation and Operation

Dual Laser InfraRed (IR) Thermometer with Color Alert

Mini Digital Altimeter & Climb rate & Barometer & Thermometer & Compass & Weather forecast & Time

Michelin User Guide. Hi-power Rapid Tyre Inflator

Druck DPI 104. GE Industrial Sensing. Digital pressure indicator User manual - K394

RS DIGITAL THERMOMETER

INSTRUCTION MANUAL DTH Fax: (503)

DM Series CONTENTS. 1. Features Applications General Calibration Dimensions Specifications Calibration procedure 7

CM100. Carbon Monoxide Meter. Users Manual Mode d emploi Bedienungshandbuch Manual d Uso Manual de uso Användarhandbok

Instruction Manual FL

CO-220 Carbon Monoxide Meter

Dual Laser InfraRed (IR) Thermometer

Installation and Operation Back-UPS 1250, 1300, 1500

Mini InfraRed Thermometer with Laser Pointer

Deluxe Electronic Body Fat Analyzer Body Weight Scale

EK908FHL - Thermostat for floor heating

INSTRUCTION MANUAL OVERVIEW Remote Meter: MT-5 Remote meter (Model MT-5) is available to connect with solar controller Tracer MPPT series.

Pocket Tach 99 (PT99) Non-Contact Tachometer

Wide Range InfraRed (IR) Thermometer with Type K input and Laser Pointer

Dual Laser InfraRed (IR) Thermometer

DG-700 Simulator And DG-700 Pressure and Flow Gauge Operating Instructions

NX-591NE-GSM NetworX GSM 3G HSPA+ Module Installation Sheet

Lenovo IdeaPad Miix 10

Register your product and get support at LFH0645 LFH0648. EN User manual

WIRELESS WEATHER STATION Model USER'S INSTRUCTIONS

Dual Laser InfraRed (IR) Thermometer

Back-UPS 650 VA 120 V with AVR (BX650CI-LM)

Specifications - Installation and Operating Instructions Ø5 [127.00] 17/64 [6.91] 1-59/64 [48.89]

Installation and Operation Manual Back-UPS BX800CI-AS/BX1100CI-AS

TECHWRENCH November 30, 2005 TECHNICAL PAGE

RS Stock No Instruction Manual RS-1340 Hot Wire Anemometer

USB-500/600 Series Low-Cost Data Loggers and Accessories

MSI3460. User Guide. Measurement Systems International. Challenger 3 Crane Scales

Microwave Meter. Instruction Manual

Melting Point. Electrothermal PRODUCT SPECIFICATIONS OPERATION

INSTRUCTIONS FOR VOICE CONTROLLED TALKING ALARM CLOCK

ACS-3S/NEW SU ELECTRONIC SINGLE/DUAL DISPLAY WEIGHING/COUNTING SCALE USER MANUAL

HOBO Single Channel Thermocouple Data Logger (UX M) Manual

RADIO CONTROLLED DIGITAL CLOCK MODELS / 88906

USB-500 Series Low-Cost Data Loggers and Accessories

Description of High Accuracy Digital Pressure Gauge Design

LinkRunner Pro TM. Network MultiMeter Quick Reference Guide. Welcome. What s in the box?

Software Features of Auto Gas Gas Analyzer Features HC, CO, CO2, Lambda, Air Fuel, NOx. Has optional RPM and Oil Temp.

InfplusWin OPERATING MANUAL

OPERATING INSTRUCTIONS

Ron 3025 Crane Scale with 1"/25mm Display

Instant Ear Thermometer

Hand-held thermometer Model CTH7000

User Manual. EtherUSB

USB-500/600 Series Low-Cost Data Loggers and Accessories

Advanced Systems Tester 900AST

TMS TANK MANAGEMENT SYSTEM

EASIDEW PORTABLE HYGROMETER INSTALLATION, OPERATION AND MAINTENANCE MANUAL

Body Fat Scale Instructions for use

Forklift/Pallet Jack Scales Table of Contents

This apparatus is designated Safety class 1 as defined in the IEC publication (Amendment 1).

Product Information Sheet UH28CS-12kV Hi Pot Tester

Owner s Manual AWM910 JENSEN AWM910 COMPACT DISC PLAYER RADIO CD COMPACT MUSIC SYSTEM MUTE AUX BAND AUX IN PUSH PUSH PWR VOL ALARM T/F AUD SPK A SPK B

BROOKFIELD MODEL VTE250 ELECTRIC VISCOSEL PROCESS VISCOMETER. Installation, Operation, and Maintenance Instructions. Manual No.

Transcription:

Digital Air Pressure Gauge Users Manual Intercomp Co. 3839 County Road 116 Medina, MN 55340, U.S.A. (763)-476-2531 1-800-328-3336 Fax: 763-476-2613 www.intercompracing.com Manual #: 700099 Rev H

Table of Contents SPECIFICATIONS...3 CONTROLS...3 ELECTRICAL...3 PERFORMANCE...3 ENVIRONMENTAL...3 PHYSICAL...3 OPERATIONS...4 CONTROLS...4 On/Off...4 Backlight...4 ZERO...4 Units Switching (PSI - Bar - kg/cm 2 )...5 PEAK HOLD MODE...5 CHANGING THE BATTERY...5 ERROR MESSAGES...6 HOW TO REACH INTERCOMP SERVICE DEPT....7 "This document is the property of Intercomp Co. It contains material and information that is confidential and protected under federal and/or state trade secret, unfair competition, and copyright law. Any reproduction, use or disclosure without written permission from Intercomp Co. is prohibited". Page 2 of 7

Specifications Controls General: Display: Zero, On/Off, backlight 4 digit LCD Electrical Batteries: 1 (9-volt) size disposable alkaline or rechargeable Nickel- Cadmium cell. Internal 14 bit A/D delivers over 16,000 internal counts. resolution: Operating pressure: Auto-Zero: Battery life: Low battery indication: Performance Accuracy: Capacity / resolution: Environmental P/N 360045: 100 x 0.01 PSI, 7 x 0.001 Bar, or 7 x 0.001 kg/cm 2 P/N 360045-150 : 150 PSI x 0.1 PSI, 10 x.01 Bar, 10 x.01 kg/cm 2 Automatically zeros off errors of zero-pressure. 300 hours with an alkaline battery 20 hours with backlight on Flashes 'batt' when battery is running low; Automatically turns off when battery power is low enough to affect reliability. ±0.1% of applied pressure. P/N 360045: 100 PSI x 0.1 PSI or 0.01 PSI P/N 360045-150 : 150 PSI x 0.1 PSI or 0.01 PSI Humidity: 10 to 95% Non-Condensing. Ambient Temperature: Operating: -10 C to +45 C / +14 F to +113 F. Storage: -40 C to +75 C / -40 F to +167 F. Air Pressure Temp: -10 C to +65 C / +14 F to +149 F. Physical Dimensions: Housing: 3.2 x 4.3 x 1.5 / 8.1cm x 11cm x 3.8cm. Hose: 29 / 74cm. Weight: 1 lb / 0.45kg. Page 3 of 7

Operations Controls 32.5 ON/OFF Press this button to turn the air gauge on. The unit quickly tests itself and when these tests have completed successfully, the system begins measuring. Press this button again to turn the unit off. As the gauge turns off it will briefly display its version number. The gauge has a 10 minute auto-off feature. If there is no change in pressure or any key pressed for 10 minutes, the gauge will automatically shut off. Backlight Press this key to toggle the backlight on and off. Display Resolution The display resolution can display by 0.1 PSI or 0.01 PSI. To toggle between the two settings press and hold the backlight key for 3 seconds. This will toggle the display and save the setting until changed again by the user. ZERO Tells the air gauge to display a zero pressure. If ZERO is pressed with pressure on the gauge, that pressure becomes the zero condition. When this pressure is removed, a negative pressure shows until the unit is zeroed again. The gauge contains a feature called Auto Zero Tracking (AZT), which corrects for slight zero changes during normal operation. If small pressures are added Page 4 of 7

slowly, the air gauge can zero them off. Units Switching (PSI - Bar - kg/cm 2 ) The air pressure gauge can toggle between PSI, Bar, and kg/cm 2. To switch units simultaneously press and hold the ZERO and backlight keys. After pressing and holding these keys for a few seconds, the unit will momentarily display: 1) PSI 2) bar 3) c2 PSI, if you have now switched to display in PSI. bar, if you have now switched to display in Bars. c2, if you have now switched to display in kg/cm 2. Peak hold mode To get into peak hold mode simultaneously press and the ZERO and backlight keys. (The Internal calibration blocking shunt must be in place). The unit will momentarily display "Peak". In peak mode the display will show only the highest pressure applied to the gauge. To exit peak hold mode, press the ZERO and backlight keys simultaneously. The display will show "nor for a few seconds and return to normal mode. NOTES: The unit will always turn on in 'normal' operating mode. During normal mode, the air pressure gauge takes 4 readings per second. During peak mode, the air pressure gauge is increased to 25 readings per second (in order to better capture the true peak pressure). Changing the Battery Turn the power off. Slide the battery hatch down. Remove the battery from the case and detach the old battery, being careful not to tug on the connector wires. Connect the new battery and return to the case. Replace the cover. Page 5 of 7

Error Messages disp EEPE OE OvEr BATT Display error, the pressure gauge is unable to display the number completely. If no pressure on the gauge, press zero to return the pressure reading to zero. EEPROM error, the pressure gauge has had it's calibration corrupted or destroyed; the gauge will require calibration. The pressure gauge is over capacity or outside the A/D converter range. Reduce the pressure to the gauge. If the gauge continues to display OE OE, the problem could be a bad sensor or a bad chip on the circuit board. The pressure gauge is over capacity. Reduce the pressure on the gauge Low battery, the unit requires a new battery. It will shut off if this message is ignored for too long. Page 6 of 7

How to reach Intercomp Service Dept. Things to know: Inform the Service Dept. that the product is a Digital Air Pressure Gauge. When was the gauge purchased? Where was the gauge purchased? What is the serial number? For Intercomp Service call or fax: (763)476-2531 Toll-Free US: 1-800-328-3336 FAX # (763)-476-2613 Copyright Intercomp Company 2010 ALL RIGHTS RESERVED Page 7 of 7