Omega Pipettor. Operating Instructions



Similar documents
CappController Pipette Controller. Operation Manual Version:

Lenntech ZETA PLUS CP & SP SERIES GRADE CHOICE. Pharmaceutical Applications

User Manual (English)

3 WATT LED SPOTLIGHT Model No. SLM

National- Spencer Inc.

XONYX Solid Surface Owner's Manual

PERSONAL PROTECTIVE EQUIPMENT (PPE)

TT TOYS TOYS - OWNER S MANUAL. We are delighted that you have decided to purchase this TT Toys Toys children s car.

PRODUCT SAFETY DATA SHEET

Li Battery Pack & Charger Safety & Operating Instructions

Personal Protective Equipment Guidelines

Instructional & Operating Manual

3.2 The Department of Environmental Health and Safety is responsible for;

Sip/Puff Switch User Guide

Microwave Meter. Instruction Manual

Nucleus Freedom BTE Rechargeable Battery (A25) and Nucleus Freedom BTE Recharger

12 Volt 30 Amp Digital Solar Charge Controller

INCOMPATIBILITY OF COMMON LABORATORY CHEMICALS

ROTOR LOADER OWNER S MANUAL

Instruction Manual. Image of SP-3015 & SP Important Safeguards. Automatic Dispensing Hot Water Pot with Reboil Function

POWER GEAR SLIDE OUT MANUAL

HAZARDOUS CHEMICAL WASTE DISPOSAL SECTION 7

Two component epoxy paste adhesive

PIPELINE INSPECTION COMPANY LTD. Portable Holiday Detectors. OPERATING INSTRUCTIONS SPY PORTABLE HOLIDAY DETECTORS Models 780, 785, & 790

USER MANUAL. 2. Get started 2.1 Overview The headset contains the following parts as shown in the figure:

Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MF08CESWW. Voltage rating: 115V~60Hz Power rating : 800W

MODEL # Introduction

ExStik TM ph Waterproof Meters

Tassimo The Art of the Perfect Cup

Nokia Bluetooth Headset BH-800 User Guide Issue 2

Black epoxy paste adhesive system

Laboratory Biosafty In Molecular Biology and its levels

WARNING: This product contains chemicals known to the state of California to cause cancer, or birth defects or other reproductive harm.

Properties of Alcohols and Phenols Experiment #3

Instant Ear Thermometer

Standard Operating Procedure for a Chemical Spill

Nokia Bluetooth Headset BH-200 User Guide

BUB-110B. Portable Power Pack. Compact USB Battery Charger for up to 5 Smartphones and Mobile Devices. User Manual

Nokia Bluetooth Headset BH /1

Installation and Operation Manual. Digital Remote Meter for Monitoring System Performance. Version: RM-1

Dear Customer, User Memo: Please visit us on facebook or twitter! Thank you for purchasing this product.

Two component epoxy paste adhesive. Ideal for bonding GRP, SMC and dissimilar substrates

OWNER S MANUAL. Model AE150/AE300/AE AMP MULTI-USE SMART BATTERY CHARGER READ ENTIRE MANUAL BEFORE USING THIS PRODUCT

JACKSON SAFETY* G80 Nitrile Chemical Resistant Gloves. Chemical Resistance Guide

Ultraviolet Germicidal Lamps Owner s Manual MODELS 1910 & 1930

How To Use A Power Supply Unit (Upu)

User Manual Table of Contents. Instructions for Using the LaserTouchOne Charging the Unit... 5 Holding the Device... 5 Treatment Steps...

Hazard Warning Signage Guidelines

EASIDEW PORTABLE HYGROMETER INSTALLATION, OPERATION AND MAINTENANCE MANUAL

RADIATION CONTROL TECHNIQUE #2 INSTRUCTIONS FOR PREPARATION OF RADIOACTIVE WASTE FOR DISPOSAL

Lead Testing and On Site Calibration for Water Testing Detection Range: 2 100ppb

ReadyNet Easy Jack 2 Voice/Data and Data Only Owner s Manual PX-211d and PX-211v

Manual for Fire Suppression & Methane Detection System

Crystal Clear Sealant

DRY-BATH INCUBATOR. MODELS I-G35, I-G55, I-120 and I-240. Owner/Operator Manual

Bottom Loading Water Dispenser

Use of Micropipettes

Portable Bluetooth Speaker. Quick Start Guide. Model: BTS201

RT-200 HI-TEST ROPE TESTER

Operating Manual Color Changing Fountains

CompacVideo Otoscope. Model (NTSC) and 23120P (PAL) Operating Instruction Manual

UV100A Ultraviolet Air Treatment System

Temperature C Cure time to reach hours LSS > 1MPa minutes

LOSB9595 1/36 th Brushless ESC and 10250Kv Motor Combination

3 Destructible Vinyl Label Material 7613T / 7930T

Draeger-Tubes and accuro Pump

How to Utilize this Chemical Resistance Guide

Disposal Manual. Mazda 6 Vehicle type GJ ( Vehicle type in VIN : JM* GJ ****** ~ ) Subject vehicle. July Mazda Motor Corporation

Laboratory 22: Properties of Alcohols

ClearView 100. Instruction Manual

13 Watt PORTABLE SOLAR POWER KIT

Protocol for Disinfection of Cell Culture and Tissue Culture in Media:

Universal Wireless Effects Controller USER S GUIDE SA115

neptune aquila serena solo Operating Instructions bath lift bath lift pillow lift mountway toilet lift bringing independence to life

Aseptic Technique. A GMP/GTP Training Module

Leak Detection System

USER MANUAL. Bottom Loading Bottled Water Dispenser SAVE THIS MANUAL FOR FUTURE USE. Model #

ELECTRIC BICYCLE OWNER S MANUAL

Multi Tube Rotator. Model No. 4632Q CE CECN /05/11

Luna/200. Luna/275. Ceiling hoist. User instruction. Important - warning. This manual must be read before the Luna is used

ELECTRIC WINE BOTTLE OPENER OWNER S MANUAL BO60. Visit our web site at

EzFlex Combustible Gas Leak Detector Model EZ40

DICKSON PW4 DICKSON. Pressure Chart Recorders. Applications & Specifications. Product. Getting Started, Charts & Accessories.

PROCEDURES FOR LABORATORY CHEMICAL WASTE DISPOSAL

DOWEX Resins as Organic Solvent Desiccants

Operating instructions Cordless K impact wrench

Extraction: Separation of Acidic Substances

SECURITY LIGHT. motion-activated. Assembly & operating instructions Solar Motion-Activated Security Light - 80 LED Lights

COMBUSTIBLE GAS AND HC REFRIGERANT LEAK DETECTOR OPERATING INSTRUCTIONS DETECTS ALL HYDROCARBON & OTHER COMBUSTIBLE GASES JB INDUSTRIES

English. Symbols used to mark instructions...3. Congratulations...5 Getting the best results...5. Warnings...6 Operating Procedure...

FRX3 Hand Turbine AM/FM/Weather Alert Radio with USB Smartphone Charger

Electric Kettle. Model: SK-1717 INSTRUCTIONS MANUAL

Digital echo-charge. Owner s Manual. Xantrex Digital echo-charge Battery Charger

Nokia Bluetooth Headset BH-607. Issue 2. 1

Nokia Bluetooth Headset BH-102. Issue 1

Name of Equipment Silver King Model SKMCD1P/C1. This equipment chapter is to be inserted in the appropriate section of the Equipment Manual.

Experiment #8 properties of Alcohols and Phenols

User s Manual AURORA 1.2K/2.2K

Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MN12CES / MN10CESWW

Ultrasonic support removal tank

Transcription:

Omega Pipettor Operating Instructions www.argos-tech.com Argos Technologies, Inc. 1551 South Scottsdale Court, Suite 200, Elgin, IL 60123, Tel (US) 800-886-8675, Tel (outside US) 847-622-0456, Fax 847-622-0454

Contents Page Subject 2 Product Overview 3 Product Description 3 Package Contents 4 Warranty Information 4/5 Getting Started 6/7 Maintenance, Care & Safety Precautions 7 Trouble Shooting 7 Replacement Parts Ordering Information 8 Chemical Compatibility Guide Product Overview Illuminated LED Array Shows battery charge Personalized Name Card Speed Control Thumbwheel Filter Tube Filter Silicon Pipette Holder Aspirate Trigger Dispense Trigger Nosepiece Power Supply/ Charging Socket 2

Product Description Thank you for your recent purchase of the Argos Omega Pipettor, the last serological pipettor you will ever need! The Omega Pipettor is a portable, lightweight and ergonomic unit for use with plastic or glass pipettes from 1-100mL. Its balanced design and contoured buttons help prevent hand fatigue even after hours of use. With its unique UV resistant plastic housing it is the pipettor of choice for use in laminar hoods or other locations exposed to UV light. Note: Please be sure and read the safety and operating instructions before use. Also, when performing the pipetting function, observe all laboratory safety guidelines including the use of protective clothing, safety goggles and gloves when handling biological samples or chemicals: Never Mouth Pipette! Package Contents Omega Pipettor Universal Power Supply Wall Mount Name Labels to Personalize Pipettor Warranty Registration Card Instruction Manual Argos Utility Knife Materials and Specification Battery: Battery Charging Time: Battery Life: Weight: Filters: Hand Case: Nosepiece: Pipette Holder: 6.5V Lithium Ion 2 Hours Standard: 0.45µm PTFE Barrier: 0.8 / 0.45µm Hydrophobic/Hydrophilic proprietary UV-resistant Resin ABS Silicone 3

WARRANTY INFORMATION Omega 1 Year Warranty Argos Omega Pipettor is warranted to be free of defects in materials and workmanship for a period of 12 months from the date of purchase, providing that: The unit has not been opened or attempted to be opened by the end user The user ensures that it has been carefully cleaned and decontaminated The unit has been operated according to the instructions and not in any improper way. In order to qualify for warranty repair; the customer must return the warranty card supplied with the unit that includes all of the information required to validate proof of purchase. Should warranty service be required, repair or replacement will be provided by Argos without charge. Freight shipping the unit to Argos will be the responsibility of the purchaser. There are no other warranties or guarantees, implied or otherwise expressed including any warranties of application or merchantability. Repair Service Should your Omega Pipettor require service or repair, please contact Argos Technologies customer service. They will issue a Return Authorization Number and advise on the proper packaging and method of shipment. Customer Service: in US: 800-886-8675 outside US: 847-622-0456 Argos Technologies, Inc. 1551 South Scottsdale Court Suite 200 Elgin, IL 60123 Attn: Technical Service Be sure to list your RA number on the shipping label. Please use the same numbers listed above, should you require any technical assistance or support. Preparation for Use Getting Started Prior to operating your Omega Pipettor, you need to charge the battery by plugging the power supply into a standard electrical source and the power jack into the socket in the base of the pipettor handle. You will need to charge the battery for 2 hours for a full charge. You cannot overcharge the battery. Power Supply Socket 4

The Omega Pipettor is equipped with an LED display that is activated during use. When all five lights are lit, the pipettor is fully charged. As the battery begins to lose its charge, the illuminated lights are reduced by one for every 20% loss of battery life. When only one bar remains illuminated, representing 20% battery power, the pipettor should be recharged. You can recharge the battery at any time without damage. Our unique Lithium ION battery is guaranteed for three years without being replaced, unlike Nickel Cadmium or Nickel Metal Hydride batteries typically provided. Operating the Pipettor - Place the Pipette firmly into the nosepiece to ensure a secure fit. - Using the continuously adjusting thumb wheel, you can control the speed of the aspiration or dispensing of your sample (dial turned left = slower, dial turned right = faster). This allows the operator to adjust the speed depending on the size of the pipette and the viscosity of the sample. - To aspirate, press the top button. The intensity of finger pressure on the button regulates the actual working speed. - To dispense, depress the bottom button to achieve the reverse effect. By using variable pressure on the aspirating and dispensing buttons, you can easily control the meniscus in the pipette. Operating Conditions Operating Temperature: Relative Humidity: Altitude: +10 - +40 C 10 90% (no condensation) 0 2,500 m 5

Maintenance, Care and Safety Precautions WARNING!! Before cleaning disconnect Pipettor from the power supply. Never clean the power supply or immerse the Pipettor in water. Safety Precautions - Never use with highly flammable or corrosive liquids - Ensure the current of your electrical source matches the voltage of the charger unit. Only use the adapter supplied with the unit. - When changing the filter, wear protective gloves to prevent accidental contamination. Do not open the Pipettor housing as it will void warranty. Replacement of Filter: Maintenance Turn the nosepiece counter clockwise until the nosepiece is separated from the pipettor. Remove the filter from the silicon pipette holder and the filter tube. Dispose of the filter and replace with a fresh one. The filter should be replaced every three months or when the filter is contaminated by liquid or the suction capacity is slowed. Note: Only use Omega replacement filters to guarantee a proper seal. Filter Tube Filter Silicone Pipette Holder Nosepiece *Never operate the Omega Pipettor without a filter. 6

Cleaning and Care The Omega Pipettor can be cleaned with most common laboratory disinfectants, including isopropanol. Never use aggressive organic solvents. The nosepiece can be autoclaved at 121 C, with the exception of the filter. Follow the procedure under Replacing the Filter to remove the filter prior to sterilization. Trouble Shooting Problem Possible Cause Remedy Slow Aspiration Filter Blocked Replace Filter Slow Aspiration Battery Low Recharge Battery Pipette Drips Pipette not secure in holder Re-insert Pipette into Pipettor Pipette Drips Pipettor Mount Damaged or Worn Replace Pipettor Mount Note that there are no user serviceable parts inside of the unit. Replacement Parts Ordering Information Omega Pipettor Part No. Description P5000 Omega Pipettor, Grey P5015 Omega Pipettor, Green P5016 Omega Pipettor, Red P5017 Omega Pipettor, Blue P5018 Omega Pipettor, Clear P5019 Omega Pipettor, Purple P1020 Silicone Pipette Holder 153 015 Sterile Filters (0.45µm) 10/PK 153 014 Non Sterile Filters (0.45µm) 10/PK 153 017 Barrier Filters (0.45 / 0.8µm) 10/PK P3225 Pipettor Mount P5025 Nosepiece Red P5070 Nosepiece Grey P3010 Battery Charger P1005 Pipettor Wall Mount P5022 Personalized Name Card 7

Chemical Compatibility Guide: R: Recommended PA: Polyamide O: Test advised POM: Polymethlenoxid L: Limited resistance NBR: Nitril rubber N: Not recommended CR: Chloroprene (Neoprene) MQ / MVQ: Silicon - caoutchouc FPM: Fluor caoutchouc (Viton) Acids PA POM NBR CR MQ / MVQ FPM Hydrochloric acid 10% L L O R L R Hydrochloric acid conc. N N L L L O Nitric acid 10% L L N O N O Nitric acid concentrated N N N L N O Alcohols PA POM NBR CR MQ / MVQ FPM Butanol R R R R O R Ethanol O R O R O O Methanol O R O O R L Amines PA POM NBR CR MQ / MVQ FPM Aniline O O L L O R Dimethylformamide R R L O R L Bases PA POM NBR CR MQ / MVQ FPM Ammonium hydroxide R L O R O L 25% Sodum hydroxide R L O R L O Hydrocarbons PA POM NBR CR MQ / MVQ FPM Hexane R R R L O L Tuloene R R N N N R Xylene R R N N N R Dioxane R O N N N L Dimethysulfoxide DMSO N N N N N N Halogenated PA POM NBR CR MQ / MVQ FPM Hydrocarbons Carbon tetrachloride R R L N N R Chloroform O L N N L O Methylene chloride O O N N N L Ketones PA POM NBR CR MQ / MVQ FPM Acetone R O N O L N Methyl ethyl ketone R R N N N N (butanone) www.argos-tech.com Argos Technologies, Inc. 1551 Scottsdale Court, Suite 200, Elgin, IL 60123, Tel (US) 800-886-8675, Tel (outside US) 847-622-0456, Fax 847-622-0454 8