3 rd Russian-Bavarian Conference on Bio-Medical Engineering



Similar documents
Cuff less Continuous Non-Invasive Blood Pressure Measurement Using Pulse Transit Time Measurement

How to measure blood pressure using digital monitors

Factors Affecting Blood Pressure. Vessel Elasticity Blood Volume Cardiac Output

Pressure Sensor Based Estimation of Pulse Transit Time

Edwards FloTrac Sensor & Edwards Vigileo Monitor. Measuring Continuous Cardiac Output with the FloTrac Sensor and Vigileo Monitor

Responses to Static (Isometric) Exercise

OEM MAXNIBP Frequently Asked Questions

Vtial sign #1: PULSE. Vital Signs: Assessment and Interpretation. Factors that influence pulse rate: Importance of Vital Signs

The Periodic Moving Average Filter for Removing Motion Artifacts from PPG Signals

Feature Vector Selection for Automatic Classification of ECG Arrhythmias

Measurement of Blood Pressure

The EasySense unit can detect that the Smart Q Heart Rate Sensor is connected and the range it is set to.

Implementation of Cloud-Computing Healthcare based on Xenon Uploading System and Hilbert Huang Transform

Doppler. Doppler. Doppler shift. Doppler Frequency. Doppler shift. Doppler shift. Chapter 19

Anatomi & Fysiologi The cardiovascular system (chapter 20) The circulation system transports; What the heart can do;

2016 PQRS OPTIONS FOR INDIVIDUAL MEASURES: CLAIMS, REGISTRY

Evaluation copy. Blood Pressure. Project PROJECT DESIGN REQUIREMENTS

Miniaturizing Photoplethysmography for Use in a Multifunctional Health Monitoring Device with Applications for Asthma Analysis

Bioinstrumentation. Kuo-Sheng Cheng, Ph.D. Department of Biomedical Engineering National Cheng Kung University

ADVANCE: a factorial randomised trial of blood pressure lowering and intensive glucose control in 11,140 patients with type 2 diabetes

Blood Pressure Assessment Program Screening Guidelines

Efficient Heart Rate Monitoring

Stress Echocardiogram

State-of-the-Art Technology in Cardiac CT

Current Renal Replacement Therapy in Korea - Insan Memorial Dialysis Registry, ESRD Registry Committee, Korean Society of Nephrology*

Direct Arterial Blood Pressure Monitoring Angel M. Rivera CVT, VTS (ECC) Animal Emergency Center Glendale, WI March 2003

Vascular System The heart can be thought of 2 separate pumps from the right ventricle, blood is pumped at a low pressure to the lungs and then back

Normal & Abnormal Intracardiac. Lancashire & South Cumbria Cardiac Network

High Blood Pressure (Essential Hypertension)

Ultrasound Technologies. PD1v. vascular pocket doppler. Operating Instructions

Fingertip Pulse Wave (PPG signal) Analysis and Heart Rate Detection Swarup Sarkar 1, Akash Kumar Bhoi 2, Gyanesh Savita 3 1,2,3

Blood pressure measurement devices. December 2013

Blood Pressure. Blood Pressure (mm Hg) pressure exerted by blood against arterial walls. Blood Pressure. Blood Pressure

Normal Intracardiac Pressures. Lancashire & South Cumbria Cardiac Network

Cardiovascular Physiology

MobiHealthcare System: Body Sensor Network Based M-Health System for Healthcare Application

11. Analysis of Case-control Studies Logistic Regression

HIGH BLOOD PRESSURE AND YOUR KIDNEYS

Hemodynamic Monitoring: Principles to Practice M. L. Cheatham, MD, FACS, FCCM

Healthy Blood Pressure Healthy Heart Beat. Initiated by the World Hypertension League

Absolute cardiovascular disease risk assessment

Cardiovascular Disease Risk Factors

biologic RR Comfort Creating dimensions in intelligent blood pressure stabilization Haemodialysis

INVESTIGATING HEART RATE AND BLOOD PRESSURE

Case study. Integrating Simulation into Nursing Curriculum. Fulda, Germany. Fulda University of Applied Sciences.

MEASURING AND RECORDING BLOOD PRESSURE

Cohort Studies. Sukon Kanchanaraksa, PhD Johns Hopkins University

Cardiorespiratory Fitness

CardioCard System. Product Specification and Sample Reports. PC-Based ECG CardioCard. PC-Based Stress. PC-Based Holter. CardioCard.

Plank 1 Tool: Hypertension Medical Assistant Training (Providence Medical Group)

HEART HEALTH WEEK 3 SUPPLEMENT. A Beginner s Guide to Cardiovascular Disease HEART FAILURE. Relatively mild, symptoms with intense exercise

Name: Age: Resting BP: Wt. kg: Est. HR max : 85%HR max : Resting HR:

Milwaukee School of Engineering Case Study: Factors that Affect Blood Pressure Instructor Version

Section Two: Arterial Pressure Monitoring

Draft comprehensive global monitoring framework and targets for the prevention and control of noncommunicable diseases

Electrocardiography I Laboratory

Prognostic impact of uric acid in patients with stable coronary artery disease

St Lucia Diabetes and Hypertension Screening and Disease Management Programs

Spurious systolic hypertension 143

AgoraLink Agora for Life Science Technologies Linköpings Universitet Kurs i Fysiologisk mätteknik Biofluidflöden

LABORATORY PROCEDURE MANUAL

Systolic Blood Pressure Intervention Trial (SPRINT) Principal Results

Dr Anne Weaver London s Air Ambulance CODE RED THE BLEEDING PATIENT

Project 4.2.1: Heart Rate

High Blood Pressure and Your Kidneys

Reducing Motion Artifact in Wearable Bio- Sensors Using MEMS Accelerometers for Active Noise Cancellation

Detection of Heart Diseases by Mathematical Artificial Intelligence Algorithm Using Phonocardiogram Signals

Upper Arm Blood Pressure Monitor SC Instructions for use

Effects of Caffeine on Cardiac and Skeletal Muscle Stimulation: A Noninvasive Study Based on a Single Dose of Caffeine

Heartbeat Monitoring Alert via SMS

Electrocardiogram (ECG) Monitoring System using Bluetooth technology

Manual Blood Pressure Measurement

Evaluation of Heart Rate Variability Using Recurrence Analysis

Modeling and Numerical Blood Flow Analysis of Tibial Artery using CFD

Section Four: Pulmonary Artery Waveform Interpretation

Exchange solutes and water with cells of the body


on a daily basis. On the whole, however, those with heart disease are more limited in their activities, including work.

Doppler Ultrasound in the Management of Fetal Growth Restriction Chukwuma I. Onyeije, M.D. Atlanta Perinatal Associates

PTA 210 PTA Technique. Vital Signs

Most probable Diagnosis

Principles of Medical Ultrasound. Pai-Chi Li Department of Electrical Engineering National Taiwan University

Scottish Diabetes Survey

Full version is >>> HERE <<<

Pitcairn Medical Practice New Patient Questionnaire

Android Based Application for Blood Pressure and Real-Time Pulse Rate Monitor with SMS Alert Notification

High Blood Pressure. Dr. Rath s Cellular Health Recommendations for Prevention and Adjunct Therapy

Spring Force Constant Determination as a Learning Tool for Graphing and Modeling

ECG SIGNAL PROCESSING AND HEART RATE FREQUENCY DETECTION METHODS

DEVELOPMENT OF EMBEDDED WEB SERVER FOR MEDICAL FIELD

6-minute walking distance: covered distance in a quick self-paced walk on a flat, hard surface in a period of 6 minutes

The science of medicine. The compassion to heal.

HEALTH RISK ASSESSMENT (HRS) QUESTIONNAIRE

Transcription:

3 rd Russian-Bavarian Conference on Bio-Medical Engineering Blood Pressure Estimation based on Pulse Transit Time and Compensation of Vertical Position Dipl.-Inform. Med. Christian Douniama Dipl.-Ing. Robert Couronné Fraunhofer Institute for Integrated Circuits, Germany Am Wolfsmantel 33 91058 Erlangen +49 (9131) 776-7349 christian.douniama@iis.fraunhofer.de Abstract A chronically high blood pressure (BP) may lead to arteriosclerosis and consequently is a risk factor for apoplectic stroke and cardiac infarction the main death causes in industrial countries. Hence, blood pressure recently has become one of the most relevant parameters for the assessment of a patients health status. For the purpose of a continuous monitoring of cardiovascular patients, we have investigated a non-invasive and continuous (beat-by-beat) blood pressure estimation model, which is not based on the occlusion of arteries (like i.e. the auscultatory or the oscillometric method), but on the so called pulse transit time (PTT). In two studies, on the one hand we have evaluated the assumed linear relationship between pulse transit time and blood pressure and on the other hand we have examined the correlation between heart-rate and pulse transit time respectively the influence of the measuring arm position on the measured PTT. Introduction Blood pressure (BP) measurements have become one of the most relevant and cost effective methods for the assessment of a patients health status. Since a chronically high BP may lead to arteriosclerosis and consequently is a risk factor for apoplectic stroke and cardiac infarction the main death causes in industrial countries a continuous monitoring of cardiovascular patients is highly recommended. Besides conventional techniques (like i.e. the auscultatory or the oscillometric method), another continuous and non-invasive, model-based approach to determine blood pressure values exists, which is not based on the occlusion of arteries but on the so called pulse wave transit time (PTT) [1]. A pulse wave in this context is defined as a

pulse pressure wave, which is caused by the contraction of the heart and which is propagating through the vascular system from the heart to the periphery. Due to the vascular systems properties (arterial diameter, vascular wall elasticity, blood viscosity and damping) there is a strong dependency between the transit time of the pulse wave (from the heart to a peripheral site) and its pressure, which is the arterial blood pressure (BP). The PTT is calculated as the temporal difference between the R-peak in an electrocardiogram (ECG) and the front slope of the following pulse wave measured by a finger photoplethysmograph (PPG) (see figure 1). In this way, one is able to form a beat-by-beat blood pressure estimation on the basis of pulse wave transit time. To evaluate the approach and the correlation between PTT and BP (which is assumed linear by many publications [2, 3, 4]), and to investigate the influence of additional parameters (in this case heart-rate and the vertical arm-position wearing the finger PPG in relation to the heart), two separate studies [5] have been carried out. Fig. 1 The definition of pulse wave transit time Evaluation of PTT/BP Model The purpose of the first study, with 15 healthy volunteers (10 males and 5 females of ages 23 56), was to evaluate the assumed linear PTT/BP model. Here, the test subjects blood pressure (and so the pulse wave transit time) was steadily altered by an ergometric exercise of about one hour. During this time, the PTT as well as the corresponding reference BP were measured every 1 2 minutes. For the calculation of the beat-by-beat transit times an ECG with a sampling frequency (fs) of 1 khz and a finger PPG with fs = 200 Hz synchronously were recorded. The corresponding reference blood pressure was measured with an auscultatory cuff. Furthermore, the ECG signal served as the source for heart rate (HR) calculation.

Examination of PPG-Position/PTT Relationship The purpose of the second study, with six healthy male volunteers (of ages 26 31), was to investigate the relationship between the vertical position (relative to the heart) of the arm wearing the finger PPG and the pulse wave transit time. For gravity reasons, the mentioned position has a significant impact on the PTT. Here, the test subjects have changed the finger PPG sensors vertical position every two minutes by raising the according arm (which was the left) from beneath heart-level (arm down) to heart-level to above heart-level (arm up). For every arm-level the PTT was determined by averaging the corresponding recorded transit times. The calculation of the pulse transit times was realized as explained above. Results of Measurements In our first study, we have observed a strong correlation between PTT and systolic blood pressure with a mean correlation coefficient of r = 0.83 (range: 0.61 0.98). In comparison, the correlation between PTT and diastolic blood pressure with mean r = 0.36 (range: 0.01 0.53) was rather weak (see figure 2). The blood pressure estimation error standard deviation in our study was in the interval 5.8 8.3 mmhg for systolic BP and in 5.9 6.7 mmhg for diastolic BP. Besides, there was also a very strong correlation between heart-rate and pulse transit time with mean r = 0.95 (range: 0.92 0.96). In our second study, as expected we have observed very significant differences in pulse transit time at different finger PPG sensor positions (see figure 3). There was a mean PTT difference (i) of 25 ms (STD: 17 ms) between heart-level and beneath heart-level and (ii) of 85 ms (STD: 53 ms) between heart-level and above heart-level. Fig. 2 Correlation between PTT and systolic BP (above) / diastolic BP (below)

Fig. 3 PTT at different arm-levels: heart-level (HL) (left); beneath HL (middle); above HL (right) Discussion In our investigations the correlation between pulse transit time and (at least) systolic blood pressure could be confirmed. So, with respect to a certain error (5.8 8.3 mmhg) the linear model turned out to be an appropriate estimator for systolic BP. To improve accuracy and reliability of the method, heart-rate has to be integrated in future model developments, since next to the PTT it was proved high correlation to the systolic blood pressure. In order to avoid severe blood pressure estimation errors, it is recommended to detect or better compensate PTT changes caused by a vertical finger PPG sensor displacement, because gravity effects in this case falsify the quantitative relationship between PTT and BP. Due to the small number of subjects these results are preliminary and have to be confirmed by studies with representative number of persons or even patients. To achieve the reliability and accuracy in blood pressure estimation sufficient for medical use additional studies have to be conducted. Especially the variance of blood pressure values over days and weeks for one person, the variance within day profiles, sex and age specialities and the influence of drug delivery should be subject to investigations.

References [1] Continuous Blood Pressure Determination during Exercise ECG Recording, D. Barschdorff, M. Erig, Journal of Biomedical Engineering 43, pp. 34 39 (1998) [2] Pulse Transit Time as an Indicator of Arterial Blood Pressure, L. A. Geddes, M. H. Voelz, C. F. Babbs, J. D. Bourland, W. A. Tacker, Psychophysiology 18, pp. 71 74 (1980) [3] Clinical Evaluation of Continuous Noninvasive Blood Pressure Monitoring: Accuracy and Tracking Capabilities, C. C. Young, J. B. Mark, W. White, A. DeBree, J. S. Vender, A. Fleming, Journal of Clinical Monitoring 11, pp. 245 252 (1995) [4] Pulse Transit Time Changes Observed with Different Limb Positions, J. Y. A Foo, S. J. Wilson, G. R. Williams, M.-A. Harris, D. M. Cooper, Physiological Measurement 26, pp. 1093 1102 (2005) [5] http://www.sensave.de/