VE 210. Velocity transducer for low-frequency measurements. » From the Vibro-Meter product line» Low-frequency compensation allows frequency



Similar documents
MPC 4. Machinery Protection Card Type MPC 4 FEATURES. Continuous on-line Machinery Protection Card

9000 Series Accelerometers Specifications

T1-40 T1-40BF T1-40V T1-38 T1-38BF T1-38V

and Accelerometers

High Temperature Acceleration System Bently Nevada* Asset Condition Monitoring

Isolated AC Sine Wave Input 3B42 / 3B43 / 3B44 FEATURES APPLICATIONS PRODUCT OVERVIEW FUNCTIONAL BLOCK DIAGRAM

T1-40 T1-40BF T1-40V T1-38 T1-38BF T1-38V

How To Use A Flowmeter

Low Frequency Velocity Sensor

Technical data. General specifications. Signal voltage V DC Signal duration. 1 s Input 2. Signal voltage. 1 s Analog output.

T-SERIES INDUSTRIAL INCLINOMETER ANALOG INTERFACE

Ferrostat Speed Sensor Series DSF Explosion Proof Versions EEx

Givare NC-SRS 280 och 880

Position Transducers with Restoring Spring 10, 25, 50, 75, 100 mm TR, TRS Series

Description. Specifications and Ordering Information and Accelerometer Acceleration Transducers

Velomitor Piezo-velocity Sensor

SENSORS. Miniature Sensors - S3Z. Advanced line of miniature Asian style of photoelectric sensors mm background suppression

SEISMIC VELOCITY TRANSDUCER T1-40

RISH CON - Hz. Salient Features : Application : Product Features: FREQUENCY TRANSDUCER

Inductive sensor NI10-M18-Y1X-H1141

Electronic Pressure Switch EDS 300

Mounting instructions. Acceleration Transducer B12. B 26.B12.10 en

Contactless Encoder RI360P0-QR24M0-INCRX2-H1181

SINEAX U553 Transducer for AC Voltage

Temperature sensor with integrated transmitter for industrial applications, MBT 3560

DSD 70 Dual Channel Hall Effect Speed Sensor for Railway Applications, compliant with EN 50155

Vehicle Brake System Monitoring 2-wire, 4-20 ma option; Intrinsic Safety Approval to E Exia IIC T4 (Tamb=60 C) BASEEFA, CENELEC EN50-020

DS 600. A contact free flux gate based current measurement sensor 600A rms

Technical. Specifications. fischer Rugged Flash Drive. New. Rugged Solution for Safe Data Storage in Harsh Environment

Proximity Transmitters and Seismic Vibration Transmitters

Electronic Pressure Switch EDS 3000

PMP 4000 Series. Druck Amplified Output Pressure Transducers. GE Sensing. Applications. Features

PD30ETB20xxIS. Photoelectrics, Background Suppression reflective with IR light. Main features. Description

AMP CO Plus Insert for Cat. 6 A Applications

Certified according to DIN EN ISO 9001 Technical Datasheet C-Flow Coriolis Mass Flow Meter

MAGTROL. ZS Series Load Cell. ZS Data Sheet. Features. Description

Duct Humidity Transmitter

OEM Pressure Transmitters for heavy-duty applications, Type MBS 1200 and MBS 1250

DMP 331. Industrial Pressure Transmitter for Low Pressure. Stainless Steel Sensor

EGSTON Standard E2xFxWx 12W

Tilt switches N3 / N4... MEMS technology, one or two axis. Use. Options. + long lifetime and highly reliability due to mechanism-free MEMS technology

Contents. Document information

D634-P Series Direct Drive Proportional Valve with Integrated 24 V Electronics ISO 4401 Size 05

Product data sheet. JUMO MIDAS Pressure Transmitter. Sales No. Order code JUMO AS /

Secure Data Drive Safe storage of sensitive data in harsh environments

- 1 - Eddy Current. Eddy current distance and displacement transducer

Cross-beam scanning system to detect slim objects. 100 mm in

Mounting Instructions. Torque Transducer. A en

4 non-safe digital I/O channels 2 IO-Link Master V1.1 slots. Figure 1. Figure 2. Type code. TBPN-L1-FDIO1-2IOL Ident no

Technical data. General specifications. Indicators/operating means. 30 Hz Multiplex operation 30 Hz / n, n = number of sensors, n 5

Material: Weight: Bearing Life: Shaft Speed: Starting Torque: Mass Moment of Inertia: Shaft Loads:

Ordering Information. Cylindrical Proximity Sensor E2E/E2E2

Telephone- and leased line modem for industrial applications TD-36

2/ These vacuum switches are used in measuring ranges between -1 and 0 bar.

Laser diffuse reflection light scanner with background suppression. Dimensioned drawing

HSP GmbH Zum Handwerkerhof Wendelstein Tel / Fax: / Web: HSP@hsshsp.de NTG-3000.

UMEC International Corporation

GAM900/GAM900S. Acceleration precisely measured and safely monitored

Capacitor Voltage Transformer. Answers for energy.

An internal gyroscope minimizes the influence of dynamic linear acceleration on slope sensor readings.

BATRON DOCUMENT NUMBER AND REVISION VL-FS-BTHQ 21605VSS-02 REV.A (BTHQ 21605VSS-FSTF-LED05W(1 DIE)) Feb/2002 BTHQ FSTF-LED WHITE 1/15

FP2 Relay. The Best Relaytion

Cable Plug acc. to DIN EN , Form A

FL ballasts Electronic dimming. PCA T5 BASIC lp Y II, W BASIC T5

Temposonics Magnetostrictive, Absolute, Non-contact Linear-Position Sensors

Instruction Manual MSC710 MSC710-U MSC710-I

MILLENIUM INSTALLATION MANUAL NTR 735 A. Simple Automation Control Module (MAS)

Subminiature Load Cell Model 8417

RPS/DPS High Accuracy Resonant Pressure Sensor. GE Measurement & Control. Features:

Decoding an Accelerometer Specification. What Sensor Manufacturer s Don t Tell You! David Lally VP Engineering PCB Piezotronics, Inc.

Description. Dimensions. Features. precision works better

Magnetic and Hydraulic-Magnetic Circuit Breaker 8340-G2...

APPLICATION NOTE How to Deal with Electrical Noise and Interference in the Measuring Chain using a NEXUS

Temp-485-Pt100. A temperature sensor (Pt100 or Pt1000) communicating over the RS-485 bus with a simple communication protocol

Vert-X 16-5V / % Ub. Applications Servodrives Dancer arm Operating table

3500/40M Proximitor* Monitor

Programmable Terminal. NPSeries. Easy Setup with the Low-cost, Compact NP Series

How To Power A Schen

Technical Specifications: The specifications represent a particular hardware platform. Application-specific software is provided.

Quick Connect. quick - simple - efficient.

Aluminum Electrolytic Capacitors Power Eurodin Printed Wiring

Differential Charge Amplifier

RX-AM4SF Receiver. Pin-out. Connections

DISCONTINUED (1998) FBR46 SERIES. MINIATURE RELAY 2 POLES 1 to 2 A (FOR SIGNAL SWITCHING) RoHS compliant FEATURES

3½ DIGIT VOLTMETER MODULE LED- / LCD- SERIES

LVDT. Inductive Position Transducer. SM Series. Key-Features:

The Do s and Don ts of Pressure Transducers

Current Monitoring Kit

Electro-pneumatic control valves

H/L = Power supply. FN = Nominal Frequency. RN = Rated value of output burden. UN = Nominal input voltage. IN = Nominal input current.

How To Control A Power Supply With A Mini Transmitter And Switch (Power Supply)

Relative and absolute pressure switch type 529

SEISMIC MONITORING & PROTECTION SYSTEMS

PCB Relays Twin Relays

TM7BDM8B expansion block - TM7 - IP67-8 DI/DO - 24V DC A - M8 connector

Sensors OXYGEN SENSORS PRESSURE SENSORS TEMPERATURE SENSORS ROTARY POTENTIOMETER SPEED SENSORS UEGO LAMBDA BOX STAND-ALONE PRT 02/03/06 P002P010 OPS04

SENSORS. Fiber Optic Sensors - S70. Advanced fiber optic amplifiers for high speed and low contrast applications

Pump_TM016. Local Display. 4-20mA. PLC/DCS Case 1. Relay Output Module. 4-20mA. Modbus. Optional. Case 2. Pump. Pump PT371 PT373 PCM370

Magnetic field sensor for pneumatic cylinders BIM-INT-Y1X-H1141

1587/1577. Insulation Multimeters. Technical Data. Two powerful tools in one.

Transcription:

for low-frequency measurements FEATURES» From the Vibro-Meter product line» Low-frequency compensation allows frequency response down to 0.5 Hz ( 3 db)» Voltage or current modulated output signal» No need for additional signal conditioner» Long-distance signal transmission with a galvanic separation unit (GSI 2x)» Any transducer mounting orientation» Top-mounted military-standard connector» Fully sealed transducer: IP68 protection rating» Temperature range: 25 to 80 C APPLICATIONS» Designed for vibration monitoring on low-speed machines» Suitable for hydraulic and steam turbine applications DESCRIPTION The velocity transducer is designed to measure absolute vibration at low-frequencies. With a frequency response down to 0.5 Hz, it is suitable for the special monitoring requirements of hydraulic turbomachinery which generally operate at low speeds (for example, between 60 and 000 RPM for hydroelectric turbines). The body of the transducer includes the signal conditioner electronics, so only an EC 4xx cable assembly is required to connect the power supply to the transducer and connect the transducer s output directly to the monitoring electronics. Good sensitivity and rugged design make the suitable for all types of low-speed industrial machinery. Its stainless steel casing and watertight sealed connector allow it to withstand damp and corrosive environments. Information contained in this document may be subject to Export Control Regulations of the European Union, USA or other countries. Each recipient of this document is responsible for ensuring that transfer or use of any information contained in this document complies with all relevant Export Control Regulations. ECN N/A. Meggitt SA / 262-03 / Version 3 / 8.03.205 / E / 0

DESCRIPTION (continued) The transducer s sensing element consists of a coil moving around a permanent magnet. This assembly produces an output voltage that is proportional to the vibration velocity. The integrated signal conditioner contains electronic circuitry that provides low-frequency compensation that allows the transducer to operate below its resonant frequency. It also provides current-based or voltagebased output signals (factory configurable). The current transmission mode (2-wire) can be used to transmit signals over a distance of up to 000 m. In this mode, the transducer transmits the signal to a GSI 2x galvanic separation unit, which provides effective insulation from differences in earth potential of up to 4 kv. The voltage transmission mode (3-wire) can be used to transmit signals over a distance of up to 200 m. The EC 4xx cables are available in lengths from 0.5 m, either with or without a flexible stainless steel hose (protection tube) for additional mechanical protection. The EC 439 is a 2-wire cable for current transmission and the EC 440 is a 3-wire cable for voltage transmission. In very harsh industrial environments, the should be installed using an EC 4xx with a flexible hose. An optional TA 4 mounting adaptor is also available to rigidly clamp the transducer to the machinery being monitored. BLOCK DIAGRAM V I or V V RFI filters Connector Sensing coil Lineariser Output stage Filtering SPECIFICATIONS General Operating principle Signal processing technique Directionality Signal transmission : Moving coil and magnet with integrated signal conditioner. See the Block diagram above. : Low-frequency compensation by the integrated signal conditioner allows the to operate below its resonant frequency : Sensitive to vibration along the longitudinal axis (long axis) only : Current modulated or voltage modulated output Operating Sensitivity Current (2-wire) transmission : 50 µa / mm / s (270 µa / in / s) ± 5 % Voltage (3-wire) transmission : 50 mv / mm / s (270 mv / in / s) ± 5 % Notes: Sensitivity is given at 23 C (73.4 F) ± 5 C for a signal of 2.7 mm / s (0.5 in / s) at 20 Hz. The is calibrated along the longitudinal axis. 2 / 0 Meggitt SA / 262-03 / Version 3 / 8.03.205 / E

SPECIFICATIONS (continued) Amplitude linearity : ± % from to 0 mm / s. ± 2 % from 0 to 00 mm / s. Dynamic measuring range : 00 mm / s peak from 0.5 to 400 Hz Overload capacity (spikes) : 00 g peak Transverse sensitivity : 5 % max. of response along sensitive axis Frequency range : 0.5 to 400 Hz Frequency response : 30 % / + 5 % from 0.5 to 3 Hz. ± 5 % from 3 to 400 Hz. Typical frequency response curves 3 2 Attenuation (db) 0 2 3 4 5 0.5 0 00 400 Frequency (Hz) 80 60 40 Phase lag ( ) 20 00 80 60 40 20 0 0.5 0 00 400 Frequency (Hz) Meggitt SA / 262-03 / Version 3 / 8.03.205 / E 3 / 0

SPECIFICATIONS (continued) Environmental Operating temperature range Short-term survival temperature Storage temperature Humidity Protection rating (according to IEC 60529) Shock acceleration (according to IEC 60068-2-27) : 25 to 80 C ( 3 to 76 F) : Up to 00 C (22 F) : 40 to 00 C ( 40 to 22 F) : Hermetically sealed : IP68 : 00 g peak (half sine-wave, ms duration) Mechanical characteristics Material Mounting Mounting base Mounting orientation Connector : Stainless steel casing : M8 x 0 mm tapped hole or mounting adaptor. See TA 4 mounting adaptor on page 9. : Can be mounted in any direction. See Mounting restraints on page 4. : Rugged circular, threaded-ring, 3-pin connector with a watertight seal (MIL-DTL-83723 series military standard) Dimensions : See Mechanical drawings on page 6 Weight : 400 g approx. Mounting restraints Allowed mounting orientation : Can be mounted in any direction, as shown in the drawing below 0 (vertical) Valid mounting orientations 90 (horizontal) +90 (horizontal) ±80 (upside down) 4 / 0 Meggitt SA / 262-03 / Version 3 / 8.03.205 / E

SPECIFICATIONS (continued) Signal transmission Current mode : 2-wire transmission supports distances up to 000 m, with a GSI 2x galvanic separation unit Sensitivity : 50 µa / mm / s Dynamic range : ± 5 ma max. Standing current : 2 ma ± ma Impedance (at 00 Hz) : 00 kω Voltage mode : 3-wire transmission supports distances up to 200 m Sensitivity : 50 mv / mm / s Dynamic range : ± 5 V max. Standing voltage : 7.5 VDC ± 5 % Impedance (at 00 Hz) : kω Power supply Voltage : 8 to 30 VDC Current : Current (2-wire) transmission : 7 ma Voltage (3-wire) transmission : 7 ma typ. Cable assemblies Cable length : User-specified lengths from 0.5 m. See Mechanical drawings on page 6. Cable type EC 439 : 2-wire cable (K 34) for current transmission EC 440 : 3-wire cable (K 34) for voltage transmission Temperature range : 50 to 20 C ( 58 to 248 F) Connector : Rugged circular, threaded-ring, 3-pin connector to mate with the (EN 2997 series aerospace standard) Optional protection : The flexible stainless steel hose (protection tube) provides additional mechanical protection, but is not leak-tight Meggitt SA / 262-03 / Version 3 / 8.03.205 / E 5 / 0

MECHANICAL DRAWINGS velocity transducer 9 Direction of velocity to provide a positive signal with 0 phase shift (ordering option C) M83723 / 88Y803N connector Master keyway Ø 33 Ø 22 Vibro-Meter 3 2 M8 0 9 0 45 93.5 9.8 For connector pinouts, see the table below MARKING Note: All dimensions are in mm unless otherwise stated. Connector pinouts: Pin Signal transmission mode Current (2-wire) Voltage (3-wire) Power supply and signal output Power supply 2 COM COM 3 --- Output signal 6 / 0 Meggitt SA / 262-03 / Version 3 / 8.03.205 / E

MECHANICAL DRAWINGS (continued) EC 439 cable assembly EC 439 cable assembly without a flexible hose (protection tube) Ordering number: 922-439 - 000-00 EN2997S60803FN connector Ø 4.5 nom. K 34 cable MARKING 6 ± 54 ± 2 50 ± 5 L in mm, from 500 in steps of 500, ± 00 or ± % (whichever is greater) Wiring diagram 3 2 Connector Cable 24V 2 COM Shield (green) EC 439 cable assembly with a flexible hose (protection tube) Ordering number: 922-439 - 000-0 EN2997S60803FN connector Flexible stainless steel protection tube K 34 cable Ø 7 nom. End sleeve (Ø 8) Ø 4.5 nom. MARKING 6 ± 70 ± 5 (8) 50 ± 5 0 L2 00 in mm, from 500 to 20000 in steps of 500 +250 L 0 in mm, from 500 in steps of 500 200 min. Wiring diagram 3 2 24V 2 COM Shield (green) Connector Cable End sleeve Note: All dimensions are in mm unless otherwise stated. Meggitt SA / 262-03 / Version 3 / 8.03.205 / E 7 / 0

MECHANICAL DRAWINGS (continued) EC 440 cable assembly EC 440 cable assembly without a flexible hose (protection tube) Ordering number: 922-440 - 000-00 EN2997S60803FN connector Ø 4.5 nom. K 34 cable MARKING 6 ± 54 ± 2 50 ± 5 L in mm, from 500 in steps of 500, ± 00 or ± % (whichever is greater) Wiring diagram 3 2 Connector Cable 24V 3 O/P 2 COM Shield (green) EC 440 cable assembly with a flexible hose (protection tube) Ordering number: 922-440 - 000-0 EN2997S60803FN connector Flexible stainless steel protection tube K 34 cable Ø 7 nom. End sleeve (Ø 8) Ø 4.5 nom. MARKING 6 ± 70 ± 5 0 L2 00 in mm, from 500 to 20000 in steps of 500 +250 L 0 in mm, from 500 in steps of 500 (8) 200 min. 50 ± 5 Wiring diagram 3 2 Connector Cable End sleeve 24V 3 O/P 2 COM Shield (green) Note: All dimensions are in mm unless otherwise stated. 8 / 0 Meggitt SA / 262-03 / Version 3 / 8.03.205 / E

MECHANICAL DRAWINGS (continued) TA 4 mounting adaptor M8 45 ~4 40 8 M8 HEX. 22 Note: All dimensions are in mm unless otherwise stated. ORDERING INFORMATION To order please specify Type Designation Ordering number Velocity transducer See below Ordering number: 40-20 - 000-0 A B C Environment (A) Standard Phase shift (C) 0 80 2 Signal transmission Sensitivity (B) Current mode (2-wire) 50 µa / mm / s Voltage mode (3-wire) 50 mv / mm / s 2 Meggitt SA / 262-03 / Version 3 / 8.03.205 / E 9 / 0

ORDERING INFORMATION (continued) To order please specify Type Designation Ordering number EC 439 2-wire cable assembly for current transmission without a flexible hose (protection tube) with a flexible hose (protection tube). Refer to sales drawings 922-439-000D00 and 922-439-000D0. Note: Cable length must be specified when ordering. 922-439-000-00 922-439-000-0 EC 440 3-wire cable assembly for voltage transmission without a flexible hose (protection tube) with a flexible hose (protection tube). Refer to sales drawings 922-440-000D00 and 922-440-000D0. Note: Cable length must be specified when ordering. 922-440-000-00 922-440-000-0 TA 4 Mounting adaptor 800-4-000-0 Headquartered in the UK, Meggitt PLC is a global engineering group specializing in extreme environment components and smart sub-systems for aerospace, defence and energy markets. Meggitt Sensing Systems is the operating division of Meggitt specializing in sensing and monitoring systems, which has operated through its antecedents since 927 under the names of ECET, Endevco, Ferroperm Piezoceramics, Lodge Ignition, Sensorex, Vibro-Meter and Wilcoxon Research. Today, these operations are integrated under one strategic business unit called Meggitt Sensing Systems, headquartered in Switzerland and providing complete systems, using these renowned brands, from a single supply base. The Meggitt Sensing Systems facility in Fribourg, Switzerland was formerly known as Vibro-Meter SA, but is now Meggitt SA. This site produces a wide range of vibration and dynamic pressure sensors capable of operation in extreme environments, leading-edge microwave sensors, electronics monitoring systems and innovative software for aerospace and land-based turbo-machinery. All statements, technical information, drawings, performance rates and descriptions in this document, whilst stated in good faith, are issued for the sole purpose of giving an approximate indication of the products described in them, and are not binding on Meggitt SA unless expressly agreed in writing. Before acquiring this product, you must evaluate it and determine if it is suitable for your intended application. Unless otherwise expressly agreed in writing with Meggitt SA, you assume all risks and liability associated with its use. Any recommendations and advice given without charge, whilst given in good faith, are not binding on Meggitt SA. Meggitt Sensing Systems takes no responsibility for any statements related to the product which are not contained in a current Meggitt Sensing Systems publication, nor for any statements contained in extracts, summaries, translations or any other documents not authored by Meggitt Sensing Systems. We reserve the right to alter any part of this publication without prior notice. In this publication, a dot (.) is used as the decimal separator and thousands are separated by thin spaces. Example: 2 345.678 90. Sales offices Your local agent Head office Meggitt Sensing Systems has offices in more than 30 countries. For a complete list, please visit our website. ISO 900 FS 584089 ABCD Meggitt SA Route de Moncor 4 PO Box 66 CH - 70 Fribourg Switzerland Tel: +4 26 407 Fax: +4 26 407 3 0 www.meggittsensingsystems.com www.vibro-meter.com 0 / 0 Meggitt SA / 262-03 / Version 3 / 8.03.205 / E