BEST PRACTICES IN LEAK DETECTION AND REPAIR (LDAR) PROGRAMS. November 06, 2014 By: François Thibodeau, Eng.



Similar documents
Leak Detection and Repair. A Best Practices Guide

(Adopted July 7, 1989)(Amended December 7, 1990) (Amended May 13, 1994) FUGITIVE EMISSIONS OF VOLATILE ORGANIC COMPOUNDS

GUIDANCE DOCUMENT ON LEAK DETECTION AND REPAIR

TECHNICAL SUPPLEMENT 3: EQUIPMENT LEAK FUGITIVES

Control Device Requirements Charts For Oil and Gas Handling and Production Facilities

THE DETECTION OF GREENHOUSE GASES

Gas Leak Detection and Visualization.

Fixing the Leaks: What Would it Cost to Clean Up Natural Gas Leaks?

What to do about Leak Detection & Repair

RULE ORGANIC COMPOUNDS - WASTEWATER COLLECTION AND SEPARATION SYSTEMS

COLORADO REGULATION 7


PENNSYLVANIA DEPARTMENT OF ENVIRONMENTAL PROTECTION

ENVIRONMENTAL STANDARDS FOR PETROLEUM OIL REFINERIES EMISSIONS. Standards for emissions from furnaces, boilers and Power Plant

Air Quality Regulation of the Oil and Gas Production Sector in Colorado and Beyond. Garry Kaufman Holland & Hart LLP

RULE DRY CLEANERS USING SOLVENT OTHER THAN PERCHLOROETHYLENE

Highlights of Colorado s New Oil and Gas Hydrocarbon Emission Reduction Rules - Adopted February 2014

COLORADO APCD IR Camera Survey Program Guidance/Protocol (rev. 11/8/11)

Garry Kaufman Colorado Air Pollution Control Division May 14, 2014

NSPS Subpart OOOO: Applicability and Compliance Basics

Energy Efficient Operations and Maintenance Strategies for Boilers

Eni experience and research with IR video-camera imaging

Estimation and Reduction Methodologies for Fugitive Emissions from Equipment

Inspection, Measuring and Test Equipment (IMTE) Calibration

Title V Compliance Verification Process

Developing Colorado s s Oil and Gas Emissions Controls Overview of the Process and Requirements

TransCanada Case Study: Emissions Management System

Nitrogen Blanketing for Methanol Storage and Transportation

USC CFC Leak Repair and Recordkeeping Procedures

FIRE EXTINGUSIHER INSPECTION, MAINTENANCE, AND TESTING PROCEDURES

Temporary Batch Plants

Site Attendance Guidelines for Automated/Unattended Monitoring and Process Controlled Facilities

Pollution Incident Response Plan

Refrigerant Compliance Policy

MEMORY RESISTORS EMISSIONS MONITORING

Elements Elements describe the essential outcomes. 1. Prepare to diagnose and repair air conditioning and HVAC system

UDOT SPILL PREVENTION and RESPONSE PLAN for CONSTRUCTION SITES

Homeowner s Guide to Maintaining a Sewage Treatment System

INDEX GENERAL

HP SUPPLIER ENVIRONMENTAL PERFORMANCE REVIEW QUESTIONNAIRE

Mechanical Engineering Technician- Plant Technician

NEW JERSEY SMALL BUSINESS ENVIRONMENTAL ASSISTANCE PROGRAM

Elements Elements describe the essential outcomes.

Chapter 7 Hydraulic System Troubleshooting

Boiler Tune-up Guide

Rutgers Environmental Health and Safety

ECHM Recommendations for Safety in multiplace medical hyperbaric chambers

RGC-IR Remote Gas Calibrator for IR400

CAR Correlation Table - Equipment Leaks (40 CFR Part 63, Subpart H (HON) through )

A cure for water damage in real estate

Pharmaceutical Wholesaler Site Inspection Checklist

Spill Prevention, Control and Countermeasure (SPCC)

Subpart XX Standards of Performance. Terminals. Environmental Protection Agency

1 Quality Assurance and Quality Control Project Plan

Safe management of industrial steam and hot water boilers A guide for owners, managers and supervisors of boilers, boiler houses and boiler plant

Continuous Monitoring Manual

Example ESD Control Program Document Based on ANSI/ESD S

NEW JERSEY SMALL BUSINESS ENVIRONMENTAL ASSISTANCE PROGRAM. Dry Cleaner Compliance Calendar 2012

COMBUSTIBLE GAS AND HC REFRIGERANT LEAK DETECTOR OPERATING INSTRUCTIONS DETECTS ALL HYDROCARBON & OTHER COMBUSTIBLE GASES JB INDUSTRIES

Guidance for Stationary Refrigeration & Air-Conditioning

Elements Elements describe the essential outcomes.

IAC 7/2/08 Agriculture and Land Stewardship[21] Ch 44, p.1

TANKER - SHORE SAFETY CHECK-LIST

Oil and Gas Air Quality Regulations and Permitting

FREQUENTLY ASKED QUESTIONS

Characterization of Greenhouse Gas Emissions Involved in Oil and Gas Exploration and Production Operations

City of Hillsboro Inflow and Infiltration Elimination Program

(a) Method 1 Sample and Velocity Traverses for Stationary Sources.

Pressure Testing (Hydrostatic / Pneumatic) Safety Guidelines

RAILROAD COMMISSION OF TEXAS APPENDIX C LIST OF E&P WASTES: EXEMPT AND NONEXEMPT

STANDARD OPERATING PROCEDURE S (SOP S) FOR HAZARDOUS ANALYSIS CRITICAL CONTROL POINT (HACCP) PLANS

STATE OF MISSOURI, DEPARTMENT OF NATURAL RESOURCES MISSOURI AIR CONSERVATION COMMISSION PERMIT TO CONSTRUCT

Welcome UST Owners & Operators!!

Calibration & Preventative Maintenance. Sally Wolfgang Manager, Quality Operations Merck & Co., Inc.

PMMIC 2013 Inspection Findings. Brian Pottebaum Rounds & Associates/PMMIC

PROCEDURE 1. QUALITY ASSURANCE REQUIREMENTS FOR GAS CONTINUOUS EMISSION MONITORING SYSTEMS USED FOR COMPLIANCE DETERMINATION

OIL & GAS PRODUCTION AUDITING

Plain English Guide for the Dry Cleaners Step By Step Approach to Understanding Federal Environmental Regulations

STANDARD FOR SECONDARY CONTAINMENT TESTING OF UNDERGROUND STORAGE TANK SYSTEMS I. INTRODUCTION

OIL POLLUTION PREVENTION REGULATIONS

A Breath of Poor Air: Inspecting Indoor Air Quality in the Classroom Ashley Schopieray

Waste Handling & Disposal

MARSHALL UNIVERSITY HAZARDOUS WASTE DISPOSAL SECTION

Annex 7 Application of Hazard Analysis and Critical Control Point (HACCP) methodology to pharmaceuticals

The Piping System Model a New Life Cycle Document. Elements of the Piping System Model

An inventory of hazardous materials used in your workplace will prove useful.

Packing and gaskets Page 029 of 040

TEST REPORT for the ARID TECHNOLOGIES VAPOR RECOVERY UNIT installed in LANTANA, FL

VISIBLE EMISSIONS TRAINING AND CERTIFICATION PROGRAM EVALUATION FORM

Fuels Safety Program. Liquid Fuels Handling Code Adoption Document Amendment

Source Sampling Manual Volume II

Colorado Oil and Gas Emissions Rules

MAKING TRANSITION AND CHANGE EASIER THROUGH INTERIM CONTRACT MANAGEMENT

Electronic Flow Switches

PAINT SPRAY GUN WASHER

Compressed Gas Cylinder Safety

Transcription:

BEST PRACTICES IN LEAK DETECTION AND REPAIR (LDAR) PROGRAMS November 06, 2014 By: François Thibodeau, Eng.

2 PRESENTATION OVERVIEW 1. Essential Components of a LDAR Program 2. LDAR Best Practices a. A Good Start b. Chemical Compounds of Interest c. Potential Leak Sources d. Identifying Components e. Accepted Leak Detection Methodologies f. Repair and Follow-up Programs g. Reporting h. QA/QC i. Database and Software j. Audits 3. Discussion and questions

3 LDAR BEST PRACTICES

4 A GOOD START A good LDAR program should start with a document specifying regulatory requirements and facility-specific procedures for component identification, monitoring, repairs and record keeping. It should establish: The objectives of the program and how to measure its success The scope of the program The roles and responsibilities of personnel involved The training program for personnel involved The procedures for leak identification, tracking and repair The procedure for maintaining and updating the database

5 CHEMICAL COMPOUNDS OF INTEREST The purpose of a LDAR program is to control and to reduce process fugitive emissions of pollutants to the atmosphere Traditionally: VOCs, HAPs and more recently GHGs The same kind of program could be used to control and reduce fugitive emissions of any other substance, as long as there is a way of detecting leaks (ex: toxic, dangerous, valuable, etc.)

6 POTENTIAL LEAK SOURCES (1 of 2) LDAR programs usually include the following sources: Pump seals Compressor seals Agitator seals Valves Flanges Connectors Open-ended lines Pressure relief devices Sampling connections

7 POTENTIAL LEAK SOURCES (2 of 2) Exemptions (CCME) Stacks Vents Combustion systems Storage tanks Open storage piles Ponds Sludge drying beds Cooling tower sumps Wastewater separators Components in vacuum service Components in heavy liquid service Components that are of leakless design Inaccessible components Valves smaller than ¾ inch Valves that are not externally activated (i.e. check valves)

8 IDENTIFYING COMPONENTS (1 of 5) Unique ID number for each component Verify with process diagrams and data

9 IDENTIFYING COMPONENTS (2 of 5)

10 IDENTIFYING COMPONENTS (3 of 5)

11 IDENTIFYING COMPONENTS (4 of 5) Positively identify on site Record relevant information about each source

12 IDENTIFYING COMPONENTS (5 of 5) Database must be updated with new or modified equipment, or when it is taken out of service Periodic field audits should be performed

13 ACCEPTED LEAK DETECTION METHODOLOGIES (1 of 5) U.S. EPA Method 21 (portable VOC analyzer) Alternate work practice (IR Camera or others)

14 ACCEPTED LEAK DETECTION METHODOLOGIES (3 of 5) EPA Method 21 Monitoring Response factors <10 Calibration precision <10% Response time <30 sec Calibrations needed every monitoring day and periodic checks (logs) Calibration gases: at least zero air and span = leak definition Subtraction of background Monitor with probe at the surface Locate maximum value and monitor for 2x response time (response time is typically 3.5 sec) Trained technicians under management of competent supervisor Periodic audits

15 ACCEPTED LEAK DETECTION METHODOLOGIES (5 of 5) Alternate Work Practice (IR Camera) Must be capable of imaging compounds that are regulated in the stream Must provide an image of the leak and the leak source Must meet a minimum detection sensitivity mass flow rate Conduct a daily check Keep records of detection sensitivity level used, analysis for determination of lowest mass fraction emission rate, daily checks and video record of leak survey Repair checks with the same detection technology At least one Method 21 monitoring per year Trained technicians under management of competent supervisor Periodic audits

16 REPAIR AND FOLLOW-UP PROGRAMS Complete repairs as soon as practicable First attempt can easily repair over half of the leaks Check for success right away, but also after a few days Failed attempts schedule for maintenance Keep records of all repair operations on each specific leak Analyze data to detect chronic leakers Consider replacing chronic leakers with leakless design components

17 REPORTING Typical reports : Leak reports, report of periodic or annual emissions, compliance reports Leak reports for the plant maintenance personnel ID number, location, process fluid, repair history, etc. Annual emissions and compliance reports for the regulating authority Emission calculation method used Emissions detailed by component type, chemical species, process unit, etc. Leak frequencies (by component and process unit) Leaks found, repaired, and postponed Results of internal audits and other QA/QC procedures

18 QUALITY ASSURANCE AND CONTROL (1 of 11) Important to ensure that monitoring method and LDAR procedures are being followed in order to achieve emissions reduction Should include: Internal and third-party audits Written procedures for: source identification; monitoring; leak identification; repairs and follow-up; database updates; emission calculations. Daily reviews/sign-off of monitoring data by LDAR supervisor Process for evaluating chronic leakers Recordkeeping Training

19 QUALITY ASSURANCE AND CONTROL (2 of 11) Internal audits Review records, logs and database on a regular basis Verify that all applicable process components are identified for monitoring Verify that all leaks are being repaired within expected timeframes Review calibration and monitoring Review daily monitoring logs: Trigger corrective measures as soon as possible Frequency of internal audits has to be adjusted to the processes audited. Daily operations should be audited more often than monthly operations.

20 QUALITY ASSURANCE AND CONTROL (3 of 11) Written procedure for source identification Specify equipment and process parameters for inclusion in the LDAR program Describe what documentation will be used (PFD, P&ID, etc.) and how sources will be identified List responsibilities for implementation and verification Identify exemptions Specify which software is used List information to be included for each source

21 QUALITY ASSURANCE AND CONTROL (4 of 11) Written procedure for monitoring Monitoring equipment to be used Training required Calibration procedure Monitoring procedure Recordkeeping Health and safety recommendations Information on specific process units Standardized forms for calibration, recordkeeping, etc.

22 QUALITY ASSURANCE AND CONTROL (5 of 11) Written procedure for leak identification Clearly define criteria to declare leaks Instructions on how to identify leaks on site and in database Good practice to apply a clearly visible leak tag

23 QUALITY ASSURANCE AND CONTROL (6 of 11) Written procedure for repairs and follow-up Specify requirements regarding delay of repairs, acceptable repair methods, re-inspection procedure and recordkeeping List steps of the repair process and establish responsibilities

24 QUALITY ASSURANCE AND CONTROL (7 of 11) Written procedure for database updates Establish responsibilities to keep the database updated with changes made in the plant Create communication channels between plant departments to inform of changes

25 QUALITY ASSURANCE AND CONTROL (8 of 11) Daily reviews and sign-offs should check for: Number of sources monitored per day per technician Method 21: should normally be between 300-600 Time between readings Should never be below 10 seconds On average in a day, should be between 30 and 60 seconds, or more Abnormal data patterns Bursts of readings Severalhigh readings after a leak was found Etc. Calibration data Calibration and verification times (beginning and end of day) Calibration drift (<10%) Calibration gases used Etc.

26 QUALITY ASSURANCE AND CONTROL (9 of 11) Evaluation of chronic leakers After several monitoring cycles, it becomes possible to detect specific components that tend to leak more often Should take place at least once a year Chronic leakers usually show that the equipment or seal or gasket used is not suitable for this particular application Special action should be taken where possible to eliminate chronic leakers (more frequent monitoring, component replacement, use of alternate sealing technologies, etc.)

27 QUALITY ASSURANCE AND CONTROL (10 of 11) Recordkeeping Procedures Signed and dated reports of QA/QC activities Daily calibration forms Database of identified components, leaks found, repairs completed, etc. List of chronic leakers and action taken Audit reports and corrective actions Annual report of fugitive emissions

28 QUALITY ASSURANCE AND CONTROL (11 of 11) Training Important that all personnel involved have a sound understanding of all procedures At a minimum, there should be an internal training program in place To our knowledge, no training is currently available in Canada, at least on a regular basis. Specific training can be provided by some LDAR specialists on demand. Training sessions are available from U.S. EPA and private companies.

29 DATABASE AND SOFTWARE Considering the very large amount of data necessary to maintain a LDAR program, it is highly recommended to use a reliable LDAR software. Database will guarantee data integrity and collects all relevant information in the same place. Facilitates data analysis, recordkeeping, repairs and follow-up management, QA/QC, emission calculations and reporting.

30 AUDITS (1 of 5) Evaluation of LDAR programs can solely be done through review of reports only, but including on-site inspections is a much more reliable way to verify the overall quality of the program U.S. EPA s enforcement alert (October 1999): monitored 47,000 valves in 17 refineries. Results showed: Leak rates significantly higher than reported (5.0% vs 1.3%) Emissions significantly higher than reported (1.3 t/hr vs 0.5 t/hr) Failure to follow monitoring method adequately Estimated that monitoring at only 1 cm away from component instead of at the interface would result in missing 57% of leaks on valves!

31 AUDITS (2 of 5) Important factors that contribute to failure of detecting and permanently repairing leaks: 1. Not identifying all potential leak sources 2. Not monitoring components 3. Insufficient time spent detecting leaks 4. Incorrect positioning of probe 5. Failing to properly maintain and/or operate monitoring instrument 6. Incorrectly exempting components from monitoring 7. Unnecessarily postponing repairs 8. Inadequate repair follow-up

32 AUDITS (3 of 5) Common shortcomings Personnel with insufficient LDAR training or knowledge Parts of the process omitted Insufficient documentation for exempted components Database not updated with recent plant modifications Incomplete calibration records Improper calibration gases (expired, incorrect concentration, wrong compound) Incorrect calibration procedure (warming period, beginning and end of day (minimum), drift calculation, etc.)

33 AUDITS (4 of 5) Common shortcomings (cont d) Too many components monitored in one day Incorrect probe positioning Insufficient time to detect leaks Not measuring the background Failing to monitor at the maximum leak location Not monitoring all potential leak interfaces

34 AUDITS (5 of 5) Common shortcomings (cont d) Leaks not reported in a timely manner for repairs No follow-up on repairs Incorrect verification of repairs No evaluation of chronic leakers Improper application of emission calculation techniques Inadequate or missing QA/QC procedures Insufficient recordkeeping

35 REFERENCE François Thibodeau, Eng. 514-393-1000 francois.thibodeau@snclavalin.com

36 DISCUSSION AND QUESTIONS

37 Thank you!