Physical Specifications (Custom design available.)



Similar documents
THERMAL ANEMOMETRY ELECTRONICS, SOFTWARE AND ACCESSORIES

1.44 kw Programmable DC Power Supplies XLN Series

Quick Connect. quick - simple - efficient.

Multi-Range Programmable DC Power Supplies 9115 Series

DC Electronic Loads 8500 series

Agilent N8973A, N8974A, N8975A NFA Series Noise Figure Analyzers. Data Sheet

VOLTAGE/CURRENT CALIBRATOR ISO-TECH ILC-421

Agilent 4338B Milliohm Meter

Agilent 4339B/4349B High Resistance Meters

Voltech DC1000. Precision DC Bias Current Source

User's Guide. Integrating Sound Level Datalogger. Model Introduction

High Power Programmable DC Power Supplies PVS Series

DRTS 33. The new generation of advanced test equipments for Relays, Energy meters, Transducers and Power quality meters

Dielectric Withstand and Ground Bond Testers For Production Line Safety Agency Compliance Testing

JNIOR. Overview. Get Connected. Get Results. JNIOR Model 310. JNIOR Model 312. JNIOR Model 314. JNIOR Model 410

Duct Humidity Transmitter

NC-12 Modbus Application

Multi-Protocol decoder with Load regulation

OPERATION MANUAL. Pen type, separate electrode SOIL PH METER Model : PH-220S

Multi-Range Programmable DC Power Supplies 9115 Series

KONSTANTER SPL / SPL Programmable Electronic Load

DCS Series 1 kw, 1.2 kw, & 3 kw

A METHOD OF CALIBRATING HELMHOLTZ COILS FOR THE MEASUREMENT OF PERMANENT MAGNETS

Current Probes. User Manual

Technical Specifications: The specifications represent a particular hardware platform. Application-specific software is provided.

Mobile Communications DC Sources W

Product Information Sheet UH36 Hi Pot Tester

FREQUENCY RESPONSE ANALYZERS

Process modules Digital input PMI for 24 V DC inputs for 120 V AC inputs

PowerGem Pro Uninterruptible Power Supply

Certified according to DIN EN ISO 9001 Technical Datasheet C-Flow Coriolis Mass Flow Meter

DS 600. A contact free flux gate based current measurement sensor 600A rms

HCS-3300/3302/3304 USB Remote Programmable Laboratory Grade Switching Mode Power Supply

R60 USB to CAN interface Manual (1.5 EN)

T7560A,B,C Digital Wall Module

Research RF Sputtering Packages

Temperature & Humidity SMS Alert Controller

Voltage Regulator SPAU 341 C. Product Guide

Hand-held thermometer Model CTH7000

1. SAFETY INFORMATION

DDX 7000 & Digital Partial Discharge Detectors FEATURES APPLICATIONS

Daker DK 1, 2, 3 kva. Manuel d installation Installation manual. Part. LE05334AC-07/13-01 GF

Inductive Sensors Single or Dual Loop Detectors Type LD with teach-in

Current Monitoring Kit

Rack mounted telephone- and leased line modem for industrial applications

NUCLEAR MAGNETIC RESONANCE. Advanced Laboratory, Physics 407, University of Wisconsin Madison, Wisconsin 53706

Impedance 50 (75 connectors via adapters)

Digital Pressure Measuring Instrument MDR480

High Voltage Power Supplies

L-LAS-TB-CL serie. laser light curtains for inline measuring tasks

E. K. A. ADVANCED PHYSICS LABORATORY PHYSICS 3081, 4051 NUCLEAR MAGNETIC RESONANCE

Considerations When Specifying a DC Power Supply

Thyristor-controlled power supplies and battery chargers

MCR-VDC-UI-B-DC. Voltage Transducer for DC Voltages. INTERFACE Data Sheet _en_01. 1 Description

Isolated AC Sine Wave Input 3B42 / 3B43 / 3B44 FEATURES APPLICATIONS PRODUCT OVERVIEW FUNCTIONAL BLOCK DIAGRAM

Agilent E363xA Series Programmable DC Power Supplies. Data Sheet

Multi-Function Ground

NEW APC Smart-UPS. Advanced line interactive power protection for servers and network equipment. The world s most popular network and server UPS.

Current Monitoring Kit QUICK START GUIDE

EVAL-UFDC-1/UFDC-1M-16

Contents. Document information

MINIMAT-EC-Servo Screwdriver Spindles

Product Information Sheet UH28CS-12kV Hi Pot Tester

Technical Datasheet Scalar Network Analyzer Model MHz to 40 GHz

Multi-Protocol decoder

1587/1577. Insulation Multimeters. Technical Data. Two powerful tools in one.

How To Use An Hm804X Series Of Power Supplies

Series /16 DIN Multi-Mode Bar Graph Display Timer TIMERS PRODUCT HIGHLIGHTS

User's Guide Integrating Sound Level Datalogger Model

Electronic Pressure Switch EDS 300

Electronic Control Devices The European Product Catalogue 2007

Low and High Voltage Power Supplies

T-SERIES INDUSTRIAL INCLINOMETER ANALOG INTERFACE

DP800. Programmable Linear DC Power Supply RIGOL TECHNOLOGIES, INC.

Ultrastab 866R Six-Channel Current Transducer User Manual

4-Channel Thermometer / Datalogger

IFC 070 Technical Datasheet

Disturbance Recoder SPCR 8C27. Product Guide

RISH CON - Hz. Salient Features : Application : Product Features: FREQUENCY TRANSDUCER

USB-AD14f Data Acquisition System (USB)

User's Guide. True RMS Industrial Multimeter

USB-AD16f Data acquisition system (USB)

R&S ZNBT8 Vector Network Analyzer Specifications

Measuring static magnetic fields

EXTERNAL DIMENSIONS AND PARTS

2000 6½-Digit Multimeter

Modular I/O System Analog and Digital Interface Modules

Distributed by TestEquity LLC

How To Use A Ds340 (Dsp)

DDX 7000 & Digital Partial Discharge Detectors FEATURES APPLICATIONS

BW-500 BED WEIGHER USER MANUAL

Series 6000 Torque measured metal bellow coupling

Unidirectional Transmitter/ Receiver Units Introduction

5000V Graphical Megohmmeter Model 5070

Why Buy HVI VLF Products?

Telephone- and leased line modem for industrial applications TD-36

Automation System TROVIS 6400 TROVIS 6493 Compact Controller

Microphone Test System

Indoor / Outdoor Antenna

HEAT MONITORING AND CONTROL INSTRUMENTS FOR TRANSFORMERS MB 103 TEMPERATURE CONTROL UNIT PT 100 TEMPERATURE SENSOR

Transcription:

Helmholtz Coils A useful laboratory technique for getting a fairly uniform magnetic field, is to use a pair of circular coils on a common axis with equal currents flowing in the same sense. For a given coil radius, you can calculate the separation needed to give the most uniform central field. This separation is equal to the radius of the coils. The magnetic field lines for this geometry are illustrated below. This was the original purpose of the Helmholtz coil to create a very homogeneous magnetic field inside two separate coils. The coils would have a certain radius, and as long as they 2 coils were then separated by this exact same radius, then the magnetic field inside the 2/3 of the coils radius there was a perfect homogeneous magnetic field. Now for measuring a magnet, we do the exact opposite. We place the magnet on a flat plane inside this homogeneous area, and then we remove the magnet and it induces a voltage into a fluxmeter. A good fluxmeter is then just a integrating voltmeter. The advantage of this compared to a gaussmeter is that it doesn t depend on the operator placement of the probe to the exact position. It also doesn t matter the speed at which the magnet is removed. Therefore, this process of measuring the magnets offers the highest precision and repeatability. The Helmholtz Coil and Fluxmeter are used for the measurement of a wide range of magnet sizes, materials, and geometries without specimen destruction, complicated set-up times, or bulky and expensive equipment. Complex geometries common with Neodymium, Samarium and Hard Ferrite permanent magnets, including motor arc segments, can be easily measured. Consult one of our experienced engineers for design and application assistance. The Helmholtz coil can come in any size you want. We have 50,80,100,150,200mm as normal sizes available.

Physical Specifications (Custom design available.)

Measuring Magnetic Fields Using the The enables you to measure the magnetic values flux Φ, flux density B, field strength H and polarization J. A coil made for your specific purpose is connected to the fluxmeter as a probe. This device is suitable for sophisticated measurements in the R&D department, automatic process control, quality control, and quality conformance inspection. Due to the built-in calibrator, long term accuracy is obtained. Some examples of applications are measurement of flux density inside the air gap of magnet systems checking the polarization of magnets stray field measurements measurements of magnetic fields next to super conductors. Several steps have been taken in order to minimize drift effects. The connecting plug of each probe is equipped with a memory chip, in which the relevant data of the probe are stored. By this, faulty measurements caused by improper parameter entries are impossible. Moreover, flux densities or field strengths can be directly displayed and conversion is not required. Even the standard model of this fluxmeter has a digital interface which makes it possible to control the unit remotely. A tolerance test function and a digital peak value indicator are also built in. All required accessories such as probes, reference magnets etc. can be ordered with your fluxmeter. The advantages of a fluxmeter compared to field meters using hall probes are: that in principle there is a linearity between intensity of magnetic field and output signal a wide range of operating temperature permitted for measuring coil the possibility of measuring flux inside iron parts and magnetic potentials Edition April 2003 Page 1 of 5

Special Features low drift low thermo voltage probe connector plug built-in calibrator automatic probe recognition unit of measurement can be selected (flux, flux density, field strength, etc.) simple way of operation lit graphical display, easy to watch robust cabinet, can be mounted into 19" rack virtually all interfaces available built-in go/no-go test; user can set valves auto test when switched on pos. and neg. digital peak value indicator fast analog peak value indicator (most Gaußmeters cannot measure the sine pulse generated by a magnetizer) software update can be done via interface by using a standard PC 2nd input socket at the back panel of the cabinet frequency range 0..30 khz All inputs and outputs decoupled galvanically Technical Data construction low drift integrator followed by a 19 bit analog digital converter measuring ranges +/- 1mVs +/- 10mVs +/- 100mVs +/- 1Vs range selection automatically or manually accuracy 0.5% after self calibration noise suppression 50 / 60 Hz line power sample rate 16 conversions per second calibrator section internal reference of voltage and time drift <± 1µVs/min input resistance 1.2kΩ ± 0.1% 10.2kΩ ± 0.1% input terminals low thermovoltage miniconnectors at the front and back side of cabinet; banana plugs at the back side display graphical LCD 125mm x 35 mm², 4 digits of reading displayed, green lit, contrast can be set via menu, bargraph Analog Output I Analog Output II function continuous output of readings output voltage +/-10V inner resistance 100Ω decoupled galvanically function output of peak value, reference voltage, reference frequency output voltage 0V - 10V inner resistance 100Ω update rate 62.5 ms decoupled galvanically Edition April 2003 Page 2 of 5

Serial Interface type RS 232C connector 9-pole DB-9 plug baud rate 300-9600 Baud handshake None, DTR/DSR, XON/XOFF function memory SCPI (Standard Commands for Programmable Instruments) or printermode 512 readings Digital Outputs number 4 Digital Inputs number 4 functions log. level supply voltage output current technique standard low / high /go / run to be set in menu DC 24V (externally fed) max. 100mA short circuit proof M / P switching IEC1131 (24VDC) functions log. level supply voltage input resistance standard reset / hold or drift lock (can be set in menu) / 2 x spare to be set in menu 5-34V external / internal type. 2.2 KΩ IEC1131 (24VDC) Peak Value Measurement analog analog peak hold circuits store even short peaks. The positive and negative value is displayed. Maximum delay until output of value to analog output is 62.5 ms (as option) digital max. displayed reading is stored, time slot pattern 62.5 ms (standard) Software functions Compensation of drift Enable the external control of all fluxmeter functions Digital smoothing of reading Conversion of units Self calibration Bargraph Tolerance test Percent reading Storage of probe parameter Manual range control, auto ranging Edition April 2003 Page 3 of 5

Display Example mode of operation range input resistance tolerance test peak value bargraph time of display averaging Scope of Delivery Fluxmeter Operation manual Test report Floppy disk containing demo program ( WIN version ) Options Opt. 001 USB interface Opt. 002 IEEE-488 (GPIB) interface Opt. 003 insulated parallel BCD output Opt. 004 external tolerance display Opt. 010 additional operation manual Opt. 999 warranty 2 years Deliverable Accessories Search coils Helmholtz coils Potential coils Reference magnets Probe plug equipped with a 2 pole shielded cable, 2m long, for connection of self made coils to the fluxmeter. Built-in memory chip. Switch box for the connection of up to 5 probes to the fluxmeter. Power supply and control via single cable to fluxmeter. Coaxial cable 2m, BNC plugs at both ends Connecting cable for RS-232 interface, 2.5m long, 9 pole plugs at both ends Adaptor 9 pole plug to 25 pole socket Mounting kit for assembly of fluxmeter into 19" rack Edition April 2003 Page 4 of 5

Dimensions 125mm x 260mm x 260mm (H x W x D) 4.9" x 10.24" x 10.25" (H x W x D) Weight 3.2 Kg (7 lb.) not including packing and accessories Power Supply 100-130V / 210-250V internal voltage selection Power Line Frequency 50-60 Hz Power Consumption max. 25VA Warranty 12 months standard (24 months with Option 999) Further information? Please contact us: GmbH Rohwedderstr. 7 D-44369 Dortmund Germany Phone: +49 (0) 231 177 88-0 Fax: +49 (0) 231 177 88-22 e-mail: sales@magsys.de web: www.magsys.de systems, LLC 2401 Beech Street, Suite D Valparaiso, IN 46383-6106 USA Phone: +1 219-548-2202 Fax: +1 209-391-5637 e-mail: JMurphy@magsys.org web: www.magsys.de Asia Blk 10 Lobby B #07-22 Ubi Techpark, 10 Ubi Crescent Singapore 408564 Singapore Phone: +65-6848 4277 Fax: +65-6848 4966 e-mail: asia@magsys.de web: www.magsys.de Edition April 2003 Page 5 of 5