Rosemount 1199 Submersible Seal



Similar documents
Rosemount 1199 Submersible Seal

Rosemount 333 HART Tri-Loop

Rosemount 333 HART Tri-Loop

Replacing Displacers with Guided Wave Radar

THE WORLD'S FIRST WIRELESS GUIDED WAVE RADAR

Reliable Pressure Measurement with Remote Diaphragm Seals in Cold Weather Applications

Rosemount 752 FOUNDATION fieldbus Remote Indicator

1.1 Fill fluids. Rosemount DP Level Fill Fluid Specifications July Technical Note , Rev DB

Techniques for Interconnecting Smart Wireless Gateways to ProSoft RadioLinx Devices

Import the Gateway Certificate to the Browser

LEVEL AND VOLUME MEASUREMENTS OF BULK SOLIDS

Rosemount D Solids Scanners for Bulk Solids Inventory and Financial Reporting

Guidelines for Choosing and Installing Radar in Stilling Wells and Bypass Chambers

Quick Start Guide , Rev DA March Rosemount 8714D (Calibration Standard) Magnetic Flowtube Simulator

Rosemount DP Level Transmitters and 1199 Diaphragm Seal System

Mobrey Ultrasonic. MSP900SH Level and MSP900FH Flow Transmitters. Product Data Sheet February 2015 IP2032, Rev BA

Level Instrumentation for the Refining Industry

Rosemount 751 Field Signal Indicator

Smart Wireless Solutions. Intelligent Well Production Starts Here

Rosemount 3095 MultiVariable Transmitter with MODBUS Protocol ProductDiscontinued

Rosemount 708 Wireless Acoustic Transmitter

EMERSON S ROSEMOUNT PROJECT MANAGEMENT OFFICE. Delivering project success for your instrumentation

Rosemount 5300 and 5400 Series Terminal Compartment Spare Part Instruction

Density Measurement. Technology: Pressure. Technical Data Sheet INTRODUCTION. S min =1.0 S max =1.2 CONSTANT LEVEL APPLICATIONS

Monitoring Water Quality For Today s Demanding World

Micro Motion Model D and DL Coriolis Flow and Density Meters

General Purpose ph/orp Sensors

Rosemount 2088 Absolute and Gage Pressure Transmitter

Rosemount 248 Wireless Temperature Transmitter

Toroidal Conductivity Sensor

Electro-Magnetic Flowmeters COPA-XT 2-Wire DT43

Emerson Smart Wireless Gateway Solutions

Best Practices for Reducing Transmitter Life Cycle Costs

Certified according to DIN EN ISO 9001 Technical Datasheet KVO Series Vortex Flow Meter

Rosemount Manifolds. Product Data Sheet August , Rev PE. Factory assembled, leak-tested, and calibrated

Rosemount 3051 Pressure Transmitter

MTI10 Insertion and MTL10 In-line Thermal Mass Flowmeter and Temperature Transmitter

Micro Motion ELITE CMFS Series Meter

Emerson s Smart Wireless and WIB Requirements

Baumann Flexsleev Sanitary Control Valve

Rosemount 3051S Series of Instrumentation

3DLevelScanner II TECHNICAL DATA SHEET

Dimensions. LUC-M20 with F12 housing and process connection 2" approx. 86 AF60 G2 2 NPT Ø50. Additional dimensions see section dimensions.

Model 3051 Pressure Transmitter with HART Protocol

Baumann Way Bronze or Stainless Steel Control Valve

Bristol Series 5453 Indicating Pneumatic Pressure Controllers/Transmitters

For Multi-Parameter Meters see mvx

SupportNet Technical Services

RHE12. Hazardous Area Coriolis Mass Flow Transmitter. Features. Applications. Benefits

Fisher 377 Trip Valve

How To Use A Flowmeter

Baumann Mikroseal Control Valve

Model 43AP Pneumatic Controller, Style B

BURSTCHECK LINE OF RUPTURE DISC BURST INDICATORS

Plastic tube flowmeters Series PT/PS

Electromagnetic Flow Meter

Baumann Little Scotty Bronze Control Valve

Technical Data Sheet. 3DLevelScanner

Rosemount 2088 Absolute and Gage Pressure Transmitter

Mobrey open channel flow measurement systems

DiwiTherm, Resistance Thermometers Model TR75, with digital Display Battery or Solar Powered

The Unique Accelabar Flow Meter

S-series SQ Controller

Diaphragm Seal with flush diaphragm and flange acc.to SMS. Completed with pressure gauge in stainless steel, liquid filled or pressure transmitter

Digital inductive conductivity transmitter

MAGTECH MAGNETIC LEVEL INDICATORS

Tyco PremiAir Pneumatic Actuators

Spira-trol TM Two-port Control Valves EN Standard KE, KF and KL DN15 to DN300 and ASME Standard KEA, KFA and KLA ½" to 12"

SUPRApak Multi-Stack Series Filter Housings SUPRApak Filtration For High Volume Depth Filtration

Turbine Flowmeters for Gas Applications

Quick Start Guide , Rev DA June Emerson Smart Wireless Gateway 1410

ATEX Installation Instructions for Micro Motion ELITE CMFS Sensors

Wilockx Chris. Level Basics

Emerson Smart Wireless Gateway

Mobrey Hydrastep and Hydratect

Fisher 657 and 667 Diaphragm Actuators

AT500 Magnetostrictive Level Transmitter. Compact magnetostrictive liquid level transmitter for direct insertion K-TEK Products

Microcor Wireless Transmitter (MWT)

Rosemount 214C Temperature Sensors

Types 66R and 66RR Low-Pressure Relief Valves

Trunnion-Design Ball Valves

Variable Area Flowmeters

OPERATING and MAINTENANCE MANUAL SERIES 2700A CONTROL VALVE CONTENTS. INTRODUCTION...1 Scope...1 Description...1 Valve Identification...

DREXELBROOK. USonic-R Series. Ultrasonic Level Measurement System. User Friendly

Flow Sensors. Convenient, Reliable and Economical Flow Measurement. THORNTON Leading Pure Water Analytics

ROC800-Series Advanced Pulse Module

TECHNICAL BULLETIN. Kämmer LinedFlow Corrosive Application Valves. Experience In Motion FCD KMENTB /12

Stainless Steel Valves For the Sanitary Industries

Digital pressure gauge for industrial applications Model DG-10-S, Standard version Model DG-10-E, Enhanced version

SKP Series SKP15U.. Gas Valve Actuator with Safety Shutoff Function

ISORIA. Centered disc butterfly valves with AMRING elastomer liner. 240 PSI: 1½ to PSI : 10 to 24

Plate heat exchanger. Applications General heating and cooling duties. Heating by means of steam.

Actuators & Positioners LP - Linear Pneumatic Piston Actuator. Cylinder Actuators. High resolution, sensitivity, and fast response

Rosemount 248 Temperature Transmitter

SLAM-SHUT VALVE. Type OSE. Europe, Middle East, Africa and Asia Pacific Documents Only. Process Management TM

SITRANS F flowmeters SITRANS F M

OPTIMASS 1400 Technical Datasheet

Laminar Flow Elements

Air Eliminators and Combination Air Eliminators Strainers

Transcription:

Product Data Sheet July 2013 00813-0400-4016, Rev AA The Rosemount Submersible Seal design uses innovative DP level technology to measure level for top-down applications. For this design, the seal and capillary are submersed in the process and installation is made through a connection at the top of the tank. This differs from traditional DP Level installations which are side mounted to tanks via threaded, flanged or hygienic connections, with only the diaphragm seal in contact with the process. The unique design of the Submersible Seal allows installation through small tank connections while at the same time providing excellent performance and sensitivity characteristics.

July 2013 Proven, Reliable, and Innovative Remote Seal Technology for Top Down Measurement Unlike traditional DP Level systems that use flat diaphragm seals to measure process pressure, the Submersible Seal consists of a compressed bellows design. This design allows the seal to fit through small tank connections, a 1 1 /2 NPT threaded connection or a 2 to 3 inch flanged connection (DN 50 to DN 100), and be submersed into the fluid to provide a top-down level measurement. In addition, this seal design provides significantly better performance compared to a similar sized traditional DP Level diaphragm seal. The can be combined with any Rosemount In-Line Gage Transmitter including all output protocols and hazardous location approvals. Based on reliable and easy to use pressure based level technology Ideal for smaller top-down tank connections, from 1 1 /2 NPT threaded connections to 2-3 inch flanged connections (DN 50 to DN 100). Intended for Vented or Open Tank Applications Assemble to any Rosemount In-Line Gage Transmitter Rosemount 3051S_T 4-20 ma HART, WirelessHART, FOUNDATION fieldbus, Profibus Rosemount 3051T 4-20 ma HART, WirelessHART, FOUNDATION fieldbus, Profibus Rosemount 2051 4-20 ma HART, WirelessHART, FOUNDATION fieldbus, Profibus Rosemount 2088 Submersible Seal System with Wireless Rosemount 3051T 4-20 ma HART Contents Ordering information...................................................................................... 3 Specifications............................................................................................. 6 Dimensional drawings...................................................................................... 7 2

July 2013 Ordering information The can be ordered with any Rosemount In-Line Transmitter with the 1199 attach to option. Please refer to the desired Rosemount transmitter PDS for the desired configuration. Ordering Codes Transmitter Model 3051S_TG 3051TG, 2051TG, 2088G 1 Seal B11 S1 Table 1. The offering represents the most common options. The starred options ( ) should be selected for best delivery. The Expanded offering is subject to additional delivery lead time. Model Product Description 1199 Seal Systems Type Seal System Seal Location All In-Line Transmitters (3051S_TG, 3051TG, 2051TG, 2088G) W All Welded One Seal System High Side of Transmitter Seal Fill Fluid Specific Gravity at 77 F (25 C) Temperature Limits (1) D Silicone 200 0.93-49 to 401 F (-45 to 205 C) G Glycerin and Water 1.13 5 to 203 F (-15 to 95 C) Seal Type / ID, Description B 0.03-in. (0.711 mm) ID C 0.04-in. (1.092 mm) ID E 0.03-in. (0.711 mm) ID, PVC Coated with Closed End F 0.04-in. (1.092 mm) ID, PVC Coated with Closed End Measurement Length (2) 01 1.7 ft (0.5 m) 51 2.3 ft (0.7 m) 52 3.9 ft (1.2 m) 05 5.7 ft (1.7 m) 54 7.2 ft (2.2 m) 55 8.9 ft (2.7 m) 10 10.7 ft (3.2 m) 57 12.1 ft (3.7 m) 58 13.8 ft (4.2 m) 15 15.7 ft (4.7 m) 59 17 ft (5.2 m) 60 20.3 ft (6.2 m) 20 20.7 ft (6.3 m) 3

July 2013 Table 1. The offering represents the most common options. The starred options ( ) should be selected for best delivery. The Expanded offering is subject to additional delivery lead time. 61 23.6 ft (7.2 m) 25 25.7 ft (7.8 m) 62 26.9 ft (8.2 m) 63 30.2 ft (9.2 m) 30 30.7 ft (9.3 m) Industry A ASME B16.5/ANSI B1.20.1 (American National s Institute/American Society of Mechanical Engineers) D EN 1092-1 (European ) J JIS B2238 Process Style TSM Threaded Submersible Seal Expanded Expanded FSM Flanged Submersible Seal Process Size Threaded (TSM) ANSI B1.20.1 ISO 7-1, DIN 2999, BS 21 (BS EN 10226-1), JIS B0203 4 1 1 /2-11.5 NPT - Expanded Expanded Flanged (FSM) JIS B2238 ASME B16.5 / HG20615 EN 1092-1 / GOST 12815-80 / HG20592 4 40 A 1 1 /2 in. - G 50 A 2 in. DN 50 7 80 A 3 in. - J - - DN 80 9 100 A - DN 100 F - - DN 40 Pressure Rating Threaded (TSM) ANSI B1.20.1 ISO 7-1, DIN 2999, BS 21 (BS EN 10226-1), JIS B0203 0 60 psi 4.13 bar Flanged (FSM) JIS B2238 ASME B16.5 / HG20615 EN 1092-1 / GOST 12815-80 / HG20592 1 10K Class 150-2 20K Class 300-4 40K Class 600 - G - - PN 40 E - - PN 10 / 16 4

July 2013 Table 1. The offering represents the most common options. The starred options ( ) should be selected for best delivery. The Expanded offering is subject to additional delivery lead time. Diaphragm, Upper Housing, Flange Material Diaphragm Upper Housing Flange DG 321 SST 316 SST 316 SST Process Filter 000 No Filter 001 1 /4 in. NPT Screen Insert (1) At ambient pressure of 14.7 psia (1 bar-a) and ambient temperature of 70 F and must be further derated if ambient temperature exceeds 70 F (21 C). (2) Length is measured from the bottom of the threaded connection or gasket surface of the flange to the bottom of the seal. Please refer to the TSM and FSM drawings. 5

July 2013 Specifications Functional specifications Maximum working pressure limits Table 2. Maximum working pressure limits Rosemount 3051S_TG, Rosemount 3051T, Range Rosemount 2051T and Rosemount 2088 1 30 psig (2,07 bar) 2 60 psig (4,14 bar) Temperature limits Transmitter temperature limits 40 to 185 F (-40 to 85 C) With LCD display (1) : -40 to 175 F (-40 to 80 C) With option code P0: -20 to 185 F (-29 to 85 C) (1) LCD display may not be readable and LCD updates will be slower at temperatures below -4 F (-20 C). Fill fluid temperature limits Table 3. Fill fluid specifications Specific Gravity at 77 F Fill Fluid (25 C) Coeff. Of Therm. Exp. (cc/cc/ C) Viscosity at 77 F (25 C) (Centistokes) Silicone 200 0.93 0.00108 9.5 Glycerin and Water 1.13 0.00034 12.5 Temperature Limits -49 to 401 F (-45 to 205 C) 5 to 203 F (-15 to 95 C) Physical specifications Materials of construction Seal Diaphragm: 321 SST : 316 SST Armor: 304 SST or PVC-Coated 304 SST 6

July 2013 Dimensional drawings 3D drawing 2D dimensional drawing 1.605 (40,77) 3.57 (90,7) Dimensions are in inches (millimeters) with Optional Screen Insert 7

July 2013 Rosemount Submersible Seal Threaded Submersible Seal (TSM Process Style) Side View Flanged Submersible Seal (FSM Process Style) Side View 2.47 62.74 2.47 62.74 Measurement Length Measurement Length Dimensions are in inches (millimeters) 8

July 2013 Rosemount 3051S_T with Submersible Seal Threaded PlantWeb Housing Front View 4.20 (107) Junction Box Housing Front View 4.20 (107) 6.88 (174) Wireless Housing Front View External Antenna Extended Range External Antenna 90 8.04 (204) 8.04 (204) 3.55 (90.1) 4.20 (107) 11.16 (283) Side View 5.21 (132) 4.55 (116) Side View 3.45 (88) 6.88 (174) Side View 6.71 (170) 6.05 (155) 8.19 (208) Dimensions are in inches (millimeters) 9

July 2013 Rosemount 3051T with Submersible Seal Threaded Rosemount 3051T Dimensional Drawings 4.1 (105) 5.32 (135) 4.45 (113) 7.2 (183) Rosemount 3051T Wireless Housing Dimensional Drawings 4.22 (107.1) 5.62 (142.9) 7.49 (190.3) U-Bolt Bracket Dimensions are in inches (millimeters) 10

July 2013 Rosemount 2051T with Submersible Seal Threaded 3.85 (98) Rosemount 2051T Dimensional Drawings 5.66 (144) 5.20 (132) 4.36 (111) 7.15 (182) Fieldbus Display Cover HART Display Cover Transmitter Circuitry Terminal s Rosemount 2051T Wireless Housing 4.22 (107.1) 5.62 (142.9) 7.49 (190.3) U-Bolt Bracket Dimensions are in inches (millimeters) 11

00813-0400-4016 Rev AA Product Data Sheet July 2013 Rosemount 2088 with Submersible Seal Threaded Rosemount 2088 0.75 (20) Clearance for Cover Removal 2 X ½ 14 NPT Conduit 5.0 (127) 4.3 (110) Max Optional Display Cover Transmitter Circuitry 3.9 (99) 4.7 (120) Certifications Tag 5.75 (146) Typical Terminal s Dimensions are in inches (millimeters) Emerson Process Management Rosemount Inc. 8200 Market Boulevard Chanhassen, MN 55317 USA T (U.S.) 1-800-999-9307 T (International) (952) 906-8888 F (952) 906 8889 Emerson Process Management Latin America 1300 Concord Terrace, Suite 400 Sunrise Florida 33323 USA Tel + 1 954 846 5030 Emerson Process Management Asia Pacific Pte Ltd 1 Pandan Crescent Singapore 128461 Tel +65 6777 8211 Fax +65 6777 0947 Service Support Hotline : +65 6770 8711 Email : Enquiries@AP.EmersonProcess.com Emerson Process Management Blegistrasse 23 P.O. Box 1046 CH 6341 Baar Switzerland Tel +41 (0) 41 768 6111 Fax +41 (0) 41 768 6300 Emerson FZE P.O. Box 17033 Jebel Ali Free Zone Dubai UAE Tel +971 4 811 8100 Fax +971 4 886 5465 Terms and Conditions of Sale can be found at \terms_of_sale The Emerson logo is a trade mark and service mark of Emerson Electric Co. Rosemount and the Rosemount logotype are registered trademarks of Rosemount Inc. PlantWeb is a registered trademark of one of the Emerson Process Management group of companies. HART and WirelessHART are registered trademarks of the HART Communication Foundation All other marks are the property of their respective owners. 2012 Rosemount Inc. All rights reserved.